Loading...
Specifications (13) RECETITED Approved plans . shall be on job site. JUL I , ?OP STRUCTURAL CALCULATIONS BUILDING CIITYF TIGAR(y _DI DIVISION To OFFICE COPY Washington County For CITY OPTIGARD REVIR D FOR CODE COMPLIANCE 10824 SW 118th Ct.,Tigard,OR Approved: I OTC: I Bearing wall demo • Permit#: - 00 A_--7 Submitted Address: A a u Sw f g Suite#: 5/22/17 By: Date: 7 TABLE OF CONTENTS Calculations 1-7 Plan markup SK1 Framing detail SK2 The bearing wall between the dining room and living room is being demoed. A glulam beam is being added to support the floor framing. Due to an adequate stem wall foundation no foundation modifications/additions are required. If there are any questions please contact David Linton, 541-510-7200. p PROFfiss 0AGINEER ��' � 837 301 /4 r 9L C✓�Y2(.1, 2U K0 1/4311S 5/22/2017 Page I 1 Wood Rafters PROJECT NAME: 10824 SW 118th Tigard DATE: 5/22/17 E Unit Definitions Q FLOOR BEAM Basic Input Input OutputVeri ! i f iN ttAtast ` is Cleft)il ;a e.� 3i.• : ," . ' - / bearin2 _ i, 4- ) .., v. ,, • -. 4i or 1 :4n 3 (15.67ft 10.33ft wa= 156•plf ) wd= 12psf 2 + 2 40psf wL=520 plf wL wd 12psf w=676•plf w:= wd+ wL 1 := 19ft M =3.1 x 104 ft-lb VF,. -—, V=6.4 x 103 lb 2ti I ptot=0.95 in Otot 240 1 OL =0.633 in OL _ 360 Wood Properties -24F-V4 Glulam Fb:= 2400psi F,,:= 265psi E:= 1800000psi CD:= 1.0 Cfu:= 1.0 CM:= 1.0 Ce= 1.0 Ct:= 1.0 CL:= 1.0 C;:= 1.0 b =.5$'n d'•= 15in 1 3 S:= b d2 =206.25 in3 A:= b•d= 82.5-in2 I:= b•12 = 1.547 x 103 in4 6 21ft10'1 12in10.1 5.125in10'1 Cv=0.98 C�= min 1.0, 1 I \ / b J 3 Fb, := bD' M' t-CmF •C C C C C C Cc Fb, =2.354x 10 -psi FV Fv•CD•CMCtC, Fv=265•psi E'•— ECM C, E`=1.8 x 106-psi M SCeq= 155.505•in3 SCeq =0.754 SCeq F S b 1.5 V ACeq=36.351 int ACeq =0.441 Aieq:= ":1, A 5./ 4 5 w l4 1„q:= max384E'•0tot 384E'•0Lj 'req= 1.338x 103-In 1Ceq =0.865 \ GLB 5.5x15 1 0 FLOOR BEAM 2 WOOD COLUMN PROJECT NAME: 10824 SW 118th Tigard DATE: 1/31/17 Unit Definitions U FLOOR COLUMN Column Loading and Properties B := 1 1 Solid Sawn Member 2 Glued Laminated Member 3 Round Timber Pile P:= 64001b P=6.4 x 103 lb ht:= 8-ft b := 5.5-in If round timber pile, b is the diameter d:= 5.5-in Ke:= 1.0 Column Factor Refer to NDS Appendix G le:= Ke-ht le=8 ft (1 le = 17.455 < 50 CheckO:= if e <_ 50,1,"Not Good"�d / Gheck0= 1 d lb,:= ht Unbraced length for bending c':= 0.8 if B = 1 0.8 for sawn lumber 0.85 if B =3 0.85 for round timber piles 0.9 for glued-laminated timbers 0.9 if B =2 c' =0.8 KcE:= 0.3 0.3 for visually graded lumber Kbe := 0.439 0.439 for visually graded lumber 0.418 for glued-laminated products and 0.610 for glued-laminated products and machine stress rated sawn lumber machine stress rated sawn lumber 3 Material Properties: Emin 580ksi E:= 1300-ksi CM:= 1.0 Wet Service Factor, Table 4A Fb:= 1200-psiCD:= 1.0 Load Duration Factor, See Table 2.3.2 Ft:= 825-psi Ct:= 1.0 Temperature Factor, See Table 2.3.3 Fc:= 1000-psi CT:= 1.0 Buckling Stiffness Factor, Section 4.4.2 Cr:= 1.0 Repetitive use Factor(1.15 for members used 1 as studs. See Table 4A. _ 12 to 9 if B = 1 Size Factor, See Section 4.3.6 CF' d For Sizes less than 12 deep 1 see Below 10 CF= 1.091 1291.5iin2•ft if B =2 d b ht Cfu:= 1 Flat use factor, see Table 4A Cf:= 1 Form factor, See Section 3.3.4 CF:= 0.74 Input Size factor for smaller Members if Applies, See Table 4A F"c:= FC.CD.Cm.Ct.CF F"c=740•psi Emin= Emin'Cm.Ct-CT Emin=580•ksi 4 Column Compression w/o Bending 0.822•E'min FcE �1el2 FcE ( FcE.\2 FcE 1 + - 1 + — — F"c F"c F"c CP =0.876 :— 2 c' — \ 2 c' ) c' F'c=648.294•psi Fc:= F �Cp f :—_ P fc=211.6 psi Checkl := if(fc<_F'c,"OK" ,"Not Good") Checkl ="OK" b•d 5 11111111111111111111111111111111.11.11.1........... - COMBINED LOADING, SECTION 3.9 Flexure and Axial Compression M:= P•1.5in M =800 ft.lb 2 S:= b d S=27.729•in3 6 F't:= Ft.CD CM Ct CF Fbs:= Fb-CD-CM-Ct-CF.Cfu"Cr'Cf lbT d� 5 RB : 2 \ b Kbe•E FbE:= 2 RB FbE FbE 2 FbE 1 + — 1 + — -- Fbs Fbs Fbs CL. 1.9 1.9 j .95 _ CL=0.999 M fbl := s f b2:= 0 F'bl Fb"CD"CM"Ct-CF•Cr Cf-CL F'b2= Fb.CD-CM-Ct-CF•Cfu Cr Cf let := le KcE" E'min KcE"E'min Kbe"E!min FbEI := FcEI FcE2 2 2 l 2 lee RB d) (-1) fe\2 fbi fb2 + + =0.727 F', f / f \2 F, 1 c — bl bl FcEI F�b2' 1 — FcE2 \FbEl _ /fc 2 fbt fb2 Check < 1, OKNG:= if — + + - 2 Check4="OK" 4 F'c fe fc \ fb I F'bl 1 -- - FcE1 F b2" 1 — FcE2 \FbE1 _ 6 Foundation qa:= 1500psf fe:= 2000psi fy := 60ksi P=6.4x 103 lb P,,:= P•1.6 Areq=4.267 ft2 Aieq._ _ q W= 1.25 ft W:= 15in Areq 1 req=3.413 ft LCeq ._ Existing stem wall and foundation are adequate for point load from column Fl FLOOR COLUMN 7 'b°k',D 4. , - '.'. ::'..::.' '-r.' 1 ' ., '-..i .14:,„1,,`*4 lt.'''''1" ."''''''''''vrw* . 0 ! . ; -., 'I'S, .4 - ' ''- awn/ 11‘.....„''. .SP),(0b °''�^--` ' - '' __-� NOOK 1 � KITCHEN \ M++Nu ill''' ." �� 'i /[ F �� i # , �,✓ A. � .�{ c fit / � — '(o tiac ru a�, I. 1 fiiill �'' �1 � 'sig 'p+ i ‘`Ilan'". !y a • n j��kf ' . ,. • j s i 24F V4 GLB 5.5X 15 # @ 2ND FLOORe '� et i . demo Is K `t i. BATH I rc°� y _., o _.(,, , e 'y ' a mn />; 8 0 _ bearing , '--';`4`.' 'r- ., .; .. £ ' i , . .,....,...,,,,....,..,..„..:.... ...........,_„......, „..„ : .„:,:it:,,,i......,.,..,...,,,„„!,.,,,,..,70;,„:•, ..._ „... ... x. ._ �i "� it 1111111■ ,..,...,...;.:....,.,:_4...t.4„....,.;:.,,,,,,,...: ....„.,t,....„,,..„.....r_...„,,...,...,. .....› .... 4 a CCJJ'�lp T1 5t��(? � �� ';',1,1'"*.! __:ti..i , �QIt"' Iv) kQ ; . ; f 51 X IS �� 6x6 POST EA END ' , x i q W/ SIMPSON BC ; I t tea. / A / J -a! j i ca �• �"�,�4 h�i 3x5" 5,�+' i 3°�°h.Y. � i _-i I £ . rM wkr ` Iw•: �i, s i �� R i ` ! 1 „ii.,,,,1?-7.,,,,,,,:C'',:".,''', .,-''','-',,:. ,r,-/".. :it#':',,,,:.C•f.,--:, ,:.,, ' , .::: 1 , f i ,---, •,.,.. ,/ "" ;-,, , 1 ,,, 1 Al ;1/7,-''ZI / 7 7' ) ----,,2 ee',./ --,/, <:),„,,,L (4(......-r:;) ',„-- / '' ( 6,14.„,/, PE)IL/ (!i4 i 17,r) ,-- , i , 7_2_42)61 r(joi-1,-;/// Fri_ittri-;;;74/6=7 ) ,nt , 1- '. /,' : ‘ / \ i / 1 - .. ..., . - I 1 1 1 1 i 1 ,==t-t-z--------------I II 7 = $ $ , i I / I$ 4 II $1. , /P- I' I $