Loading...
Permit (32) CITY OF TIGARD MASTER PERMIT COMMUNITY DEVELOPMENT Permit#: MST2016-00459 TtGAR 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 08/03/2017 Parcel: 1 S 135AD03400 Site address: 8759 SW SPRUCE ST Jurisdiction: Tigard Subdivision: 1990-053 PARTITION PLAT Lot: 2 Project: Hall Pointe Townhomes Project Description: Building A-New SFA BUILDING Floor Areas Required Setbacks Stories: 2 Bedrooms: 2 Required First: 590 sf Basement: sf Left Height: 28 Bathrooms: 3 Parking Spaces: Second: 600 sf Garage: sf Front: Dwelling Units: 1 Smoke Third: sf Right: Detectors: Yes Total: 1190 sf Value: $138,249.26 Rear: PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 LaundryTrays: 0 Y Rain Drain: 1 Urinals: 0 Lavatories: 4 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Storm Sewer 100 Tubs/Showers: 2 Garbage Disp: 1 Water Heaters: 1 0 Water Lines: 100 Drains: Catch Basins: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 0 Backwater Value: 1 Bckflw Prevntr: 0 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 4 Clothes Dryers: 1 Natural Gas Heat Pump: Y Hoods: 1 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 4 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add!500 sf: 1 201-400 amp: 0 201-400 amp: 0 P W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener N All Other: N Other Description: Y Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SFA VB R-3 1190 Owner: Contractor: DAVIS,EUGENE REVOCABLE LIVING T RICH DUNCAN CONSTRUCTION INC Required Items and Reports(Conditions) 10875 SW 89TH AVE 2295 RURAL AVE SE 1 Ersn Cntrl 503-639-4175 TIGARD,OR 97223 SALEM,OR 97302 PHONE: 503-246-5862 PHONE: 503-390-4999 FAX: Total Fees: $20,460.44 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952- 1-0090. You ma btain a copy of the rules or direct questions to OUNC by calling 503.232.1987 01 1.800.332.2344. Issued By: ‘-Gii9e4c. 4.STS Permittee Signature: Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. s 1 ` s Building Permit Appli . t ,r,4 44 1 Residential .a .`- 4,, , City of TigardReceived // �/"_ rd 111 �Y yd, Permit No.: rlGel .57 � 13125 SW Hall Blvd.,Tigard,Olf(41221 8 2 li 16 Plan Rev,e I Phone: 503.718.2439 Fax' 0 -��, J ) r Other Permit: 4�r/(a�3go �+ Date/By: > I G A K D Inspection Line: 503.639A14751h d z k `; R Date Ready/By: j,� Juris: B( See Page 2 for Internet: www.tigard-or. x T., 7 ..._1L ���� �_ 9 7i L ,(, l r, , fied/Method: �7 Supplemental Information ' e- S-TE-7s/9.I/sC" TYPE OF WORK REQUIRED DATA:1-AND 2-FAMILY DWELLING ®New construction 0 Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ❑Addition/alteration/replacement 0 Other: equipment,materials,labor,overhead,and the profit for the CATEGORY OF CONSTRUCTION work indicated o this application. ® 1-and 2-family dwelling 0 Conunercial/industrial Valuation: Tr321;05.3.99 ❑Accessory building 0 Multi-family Number of Brooms: 2 i 3 8 Lj 9. 9 ❑Master builder ❑Offer: Number of bathrooms: • 3 9�T JOB SITE INFORMATION AND LOCATION Total number of floors: 2 Job site address: SW Spruce St W)1 59 New dwelling area: 1190 square feet City/State/ZIP:Tigard,OR 97223 Garage/carport area: square feet Suite/bldg./apt.no.: iCi Project name:Hall Pointe Townhomes Covered porch area: 17 square feet 60,0 Cross street/directions to job site:SW Spruce St and Hall Blvd Deck area: 91 square feet S 50 api,c�aOther s tur7 square feet REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: Lot no.: Permit fees*are based on the value of the work performed. Tax map/parcel no.: Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. 190 sq ft 2 story townhouse built to Oregon Residential Specialty Code,2014 ed Valuation: $ Existing building area: square feet New building area: square feet e'l PROPERTY OWNER 0 TENANT Number of stories: Name:E&V Devlopment,LLC Type of construction: Address: 10879 SW 89'Ave Occupancy groups: City/State/ZIP:Tigard,OR 97223 Existing: Phone:(503)246-5862 Fax:(N/A) New: ® APPLICANT ®CONTACT PERSON BUILDING PERMIT FEES* Business name:Rich Duncan Construction (Please refer tofee schedule Contact name:Chad Elliott 503-910-0897 Structural plan review fee(or deposit): Address: 2295 Rural Ave SE FLS plan review fee(if applicable): City/State/ZIP:Salem,OR 97032 Total fees due upon application: 4[ Phone:(503)390-4999 Fax::(503)390-3633 Amount received: 3 T g E-mail:Chad@richduncaneonstruction.com PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* CONTRACTOR Comm- 'a1 and residential prescriptive installation o roof-top mo -d Photo Voltaic Solar Panel Sys • Business name:Rich Duncan Construction Submit two(2)s-i roof plan with co ion details Address:2295 Rural Ave SE and fire department acces ong .%•r the 2010 Oregon Solar Installation Specialty ecklist. City/State/ZIP:Salem,OR 97032 Permit Fee(incl :=s plan revie, $180.00 .5 inistrative fees): Phone:(503)4999- 390- 4 CN CI Fax:(503)399-3633 State c arge(12%of permit fee): 1.60 CB lic.:158330 -/- Total fee due upon application: $201.60 Authorized signature: /.......)0.--•—.., This permit application expires if a permit is not obtained ir within 180 days after it has been accepted as complete. *Fee methodology set by Tri-County Building Industry Print name:CHAD FEUD Date:10/13/16 Service Board. I:\BuildinglPermits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(11/02/COM/WEB) % Mechanical Permit Applic i i " �; � boli ori.lcr: I sl. oNl.ti AkrJ IL-4 Received 14 City of Tigard Date/By: PennitN9 /./$. /&raa�s`yn 13125 SW Hall Blvd.,Tigard,OR 97223 Plan Review i Phone: 503.718.2439 Fax: 503.598.19K T 18 2.016 Date/By: Other Permit: r i G A p t) Inspection Line: 503.639.4175 Date Ready/By: auris: Ila See Page 2 for Internet: www.tigard-or.gov , r a a l3 '^ Notified/Method: 0 ;t 6 r, a 3 Supplemental Information TYPE04.1N6 DiViSION COMMERCIAL FEE* SCHEDULE USE CHECKLIST Mechanical permit fees*are based on the value of the work ®New construction 0 Addition/alteration/replacement performed.Indicate the value(rounded to the nearest dollar)of all ❑Demolition 0 Other: mechanical materials,equipment,labor,overhead,and profit. Value:$ CATEGORY OF CONSTRUCTION RESIDENTIAL EQUIPMENT/SYSTEMS FEES* ® 1-and 2-family dwelling 0 Commercial/industrial 0 Accessory building For special information use checklist ❑Multi-family 0 Master builder 0 Other: Description Qty. Ea. Total JOB SITE INFORMATION AND LOCATION Heating/cooling: 79 Air conditioning 46.75 Job site address: SW Spruce St 8 t Furnace 100,000 BTU(ducts/vents) 46.75 City/State/ZIP:Tigard,OR 97223 Furnace 100,000+BTU(ducts/vents) 54.91 Heat pump 61.06 Suite/bldg./apt.no.: Project name:Hall Pointe Townhomes Duct work 23.32 Cross street/directions to job site:SW Spruce St&Hall Blvd Hydronic hot water system 23.32 Residential boiler(radiator or hydronic) 23.32 Unit heaters(fuel-type,not electric), in-wall,in-duct,suspended,etc. 46.75 Flue/vent for any of above 23.32 Subdivision: Lot no.: Other: 23.32 Other fuel appliances: Tax map/parcel no.: Water heater 23.32 DESCRIPTION OF WORK Gas fireplace/insert 33.39 Flue vent for water heater or gas installation of 4 remote heads for a"mini-split"system,mise sheet metal vents fireplace 23.32 microwave unit,dryer,and bath exhausts Log lighter(gas) 23.32 Wood/pellet stove 33.39 Wood fireplace/insert 23.32 Chimney/liner/flue/vent 23.32 0PROPERTY OWNER 0 TENANT Other: 23.32 Environmental exhaust and ventilation: Name:E&V Development<LLC Range hood/other kitchen Address:10879 SW 89th Ave equipment 33.39 Clothes dryer exhaust 33.39 City/State/ZIP:Tigard,OR 97223 Single-duct exhaust(bathrooms, toilet compartments,utility rooms) 23.32 Phone:(503)246-5862 Fax:(N/A) Attic/crawlspace fans 23,32 ® APPLICANT ® CONTACT PERSON Other: 23.32 Business name:Rich Duncan Construction,LLC Fuel piping: $14.15 for first four;$4.03 for each additional Contact name:Chad Elliott 503-910-0897 Furnace,etc. Address:2295 Rural Ave SE Gas heat pump Wall/suspended/unit heater City/State/ZIP:Salem,OR Water heater Phone:(503)390-4999 Fax::(503)390-3633 Fireplace Range E-mail:chad@riehduncaneonstruction.comRich Barbecue CONTRACTOR Clothes dryer(gas) Business Other: Address Advanced Mechanical Services — MECHANICAL PERMIT FEES* PO Box 1699 — Subtotal City/Stat McMinnville, OR 97128 Phone: 503-434-8544 Minimum permit fee($90.00) — Plan review(25%of permit fee) one:( CCB: 194814 — State surcharge(12%of permit fee) CCB lie.. .,,.,,,,,, TOTAL PERMIT FEE - �_ This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Authorized signature: * Fee methodology set by Tri-County Building Industry Service Board Print name:CHAD ELLO Date:10/13/16 I:\Building\Permits\MEC_PermitApp 040113.doc 440-4617T(11/02/COM/WEB) a t R.ECEIVEI : ,,, , Electrical Permit Application City of Tigard 7 Rece(ved AUGU G 0,1/ Datu'By: Pemmit 1.1 5- v2e9/4,'De)9_S i�._ 13115 SW Hall81vd.,Tigard,OR 97223 Phone: 503.718.2439 Fax: 503 598 r lr Plan Review Inspection Line: 503.639.4175 'J44'TIGAR Ready Rektea Permit N: 7 1 t; R h Internet. Ready DatelBy: Airs: el See Page t for www.tigard-or.gov �p gy� tt, Noti6cd/Method: Sappkemutai information 7. — �ji Si�! (�l r ii ..: .......... ..�%x+'fr''las""=ia.�.v:�`u.'S. ?::i• '�--Y�.�-.,"�ff ...u_-.t.'�G. ��. :_ k'�i... -r' �,r —" 3„sfi:.� �,4�•'.ly_''.,`Xr�'G ... fix �:rs,^-....�� New construction ❑Additi:o111herationlre lacementked) p Please check alt that apply(submit 2 sats ofpkem w/items checked): �-- r 1ptmre Building over three stories. ❑Demolition Other where theaiiale fault current ❑Marinas and,as1s0-1; XV. "„�i �g(1MG 'N - * < exceeds 10.000 amps at 150 volts or ❑Floating buildings. ❑ 1-and 2-family dwelling 0 Commercial/industrial 0 Accessory building leas to ground,or exceeds 14,000 p Commercial-use agricultural Multi-family 0 Master builderother installations. _ 0 Other: amps for all buildings. ❑Fire temp. Installation or ur may" 'n .. �'a�y j j.�. c;> a r:�hk.v' a p © parat 150 KVA '.. ..` a*0001,.lAR..s?7!�'.40 Gxr^M�1� ^.+: OE encY . �-^�:: z�;�•=�_.?`-���. � systemlarger separately derived Job#: Job site address:g jq SW Spruce St ❑Addition of new motor load of system. 100HP or more. "A' "E""1.2""1-3•' City/State/ZIP:Tigard,OR 97223 ❑Six or more residential units. occupancy. 0 Health-care facilities. 0 Recreational vehicle parks. Suite/bldg./apt.#: 9 Project name: Hall Pointe Townhomes 0 Hazardous locations. []Supply voltage for more than Cross street/directions to job site: 11a11 Blvd&SW Spruce ❑Service or feeder 600 amps or more. 600 volts nominal. St =: y mita_ _� O .. 0eseriydaa y �- xx''" T.e i I ' 1 0rr. 1' prat. Tatar I New residential single-or multi-family dwelling unit Subdivision: Lot#: Includes attached garage. Tax map/parcel#: 1S135AD03S00 1,000 sq.ft.or less J 168.54 /bg e,rdxl= s {- s�>r_ Ea.add'l 5 port 33.92 4 .yv .: :. :. t!OW` .... '�•_...tl`.i " - � - : .ry,_.,.,t,:_.s er sq.es de ion I '�1.t,s I' M ., i - =r:;; u Limitede energy.residential 75.00 2 (with above sq.ft.) Limited energy,multi-family residential(wish above sq.ft.) 75.00 2 .,. , h:=F,; ,e Renewable Energy-fii , t r = = x lA»n . . Services or feeders installation,alteration, d/o r relocation Name: 200 amps or less 1 100.70 100.-762 Address: 201 amps to 400 amps 133.56 2 City/State/Z1P: 401 amps to 600 amps 200.34 2 601 amps to 1,000 amps 301.04 2 Phone:( ) Fax:( ) Over 1,000 amps or volts 552.26 2 Email: Temporary services or feeders installation,alteration,and/or relocation Owner installation:This installation is being made on property that!own which is not 200 amps or less 59.36 I intended for sale,lease,rent,or exchange.according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2 Owner signature: ,. .. .- e. #::s''f:*:_,?. =�... ,xY�:<'^t:Kyi H - .-.civ °r<^� Date: amps to 599 amps 168 54 r. ..-.• ��r Branch circuits-uew,alteration ,:,.:u;:<;.::t>rr:;�;�.;� .. - -��' t ,��>,�.,. -' or extension'Qer panel .r��� "�� ����- ` %�ti""'`"` A.Fee fol brmtch circuits wish .``- �,:�:._..a��,`. Business name: E&V Development above service or feeder fee, each branch circuit 7.42 2 Contact name: Dr.Gene Davis B,Fee for branch circuits without • Address: 10875 SW 89th Ave service or feeder fee,first 56 • 18 2 • branch circuit City/State/ZIP: Tigard,OR 97223 Each add'I branch circuit 7.42 2 Phone (503)887-9966 Miscellaneous(service or feeder not included) • Fax::( ) Each manufactured or modular Email: 1inLindia@yahoo.eetn dwelling,service and/or feeder 67.84 • 2 .,,:.,, n s.. :,t Reconnect only • .•:'i:t�J':sY+. moi.=f'':y. y:... ,...e.w......... r. �• � 4. .. Pump or irrigation circle 67.84 2 Business name: ProTech Power Sign or outline lighting 67.84 2 Address: 17937 McEwen Rd#200 Signal circuit(s)or limited-energy panel,alteration,or extension, Page 2 2 City/State/ZIP: Portland,OR 97224 Each additional inspection over allowable in any of the above • Additional inspection(1 hr min) 66.25/hr • Phone:( 503)780-6207 Fax:( ) Investigation(I hr thin) 90,00/hr Email: ?./1/1/ �� ���� �� Industrial plant(l hr min) 78.18/hr / , Inspections for which no fee is CCB Lic.: 198878' / Electrical L .: C916 Z rv.Li specifically listed h hr min 90'00!hr P +� ) Suprv.Electrician signature,required: ,.':,.';;r:;.w"„<`:"`vw� ' r ;;. _ .1. .�....._ �.�.:irr�,.... ..may:,:.-i1 iiii.,1 Subtotal: 30.3,16 Print name: Andrew Anderson Da : 8/2/2017 CI Plan Review Required(25%of permit fee): State surcharge(12%of permit fee): Authorized signature: TOTAL PERMIT FEE: Print name: This permit application expires if a permit is not obtained within 180 Date: days after it has been accepted as complete. I.tBmtdir7tlPerenastELC Pern>h. S - Number of inspections allowed per permit. Opp ELR_ERE.dec Rev 06/17x/01. 440.4615T(11/0S//COAL/WEB 1 I Plumbing Permit Appl> Building Fixtures ..4,,, + ,,,a i. FOR 01.F1cI: t SE ONI_l City of Tigard Received II 41 13125 SW Hall Blvd.,Tigard,OI@ E218 2016 Date/By: Permit No. 57 j6 0 x/5 ReviewC Phone: 503.718.2439 Fax 503.598 1960 D y' Other Permit No.:Inspection Line: 503.639.41 tfS ltG RT 1fARD Date Ready/By: kris: H See Page 2 for Internet: www.tigard-or.gov lr. Notified/Method: Supplemental Information TYPAIiDIVISION D FEE* SCHEDULE 0 New construction 0 Demolition For special information use checklist Desction Thl_ Ea I Total ❑Addition/alteration/replacement 0 Other: New 1-2-family dwellings(includes 100 ft.for each utility connection) CATEGORY OF CONSTRUCTION SFR(1)bath 312/0 ® 1-and 2-family dwelling 0 Commercial/industrial SFR(2)bath 437.78 ❑Accessory building 0 Multi-family - SFR(3)bath 500.32 ❑Master builderEach additional bath/kitchen 25.02 0 Other: _ Fire sprinkler( sq.ft.) Page 2 JOB SITE INFORMATION AND LOCATION g Site utilities: Job site address: SW Spruce St SI 59 Catch basin or area drain 18.76 City/Stats/ZIP:Tigard,OR 97223 Drywell,leach line,or trench drain 18.76 Footing drain(no.linear ft.: ) Page 2 Suite/bldg./apt.no.: Project name:Hall Point Townhomes _ Manufactured home utilities 50.03 Cross street/directions to job site:SW Spruce St and Hall Blvd Manholes 18.76 Rain drain connector 18.76 Sanitary sewer(no.linear ft.:_) Page 2 Storm sewer(no.linear ft.: ) Page 2 Water service(no.linear ft.:_) Page 2 Subdivision: Lot no.: Fixture or item: _ Tax map/parcel no.: Backflow preventer 31.27 DESCRIPTION OF WORK - Backwater valve 12.51 •ough and finish plumbing for 1190 sf 2 steory townhome with 2 and 1/2 bath, Clothes washer 25.02 Dishwasher 25.02 laundry,kitchen.Water and sewer on site Drinking fountain 25.02 Ejectors/sump 25.02 e PROPERTY OWNER I 0 TENANT Expansion tank 12.51 Name:E&V Development,LLC Fixture/sewer cap 25.02 Address:10879 89th Ave Floor drain/floor sink/hub 25.02 City/State/ZIP:Tigard,OR 97223 Garbage disposal 25.02 _ Hose bib 25.02 Phone:(503)246-5862 Fax:(N/A) Ice maker 12.51 ►.1 APPLICANT 0 CONTACT PERSON Interceptor/grease trap 25.02 Business name:Rich Duncan construction Medical gas(value:$ ) Page 2 Contact name:Chad Elliott 503-910-0897 Primer 12.51 - Address:2295 Rural Ave SE Roof drain(commercial) 12.51 Sink/basin/lavatory 25.02 City/State/ZIP:Salem,OR 97032 Solar units(potable water) 62.54 Phone:(503)399-4999 I Fax::(.503)390-3633 Tub/shower/shower pan 12.51 E-mail:chad@richduncanconstruction.com Urinal 25.02 CONTRACTOR Water closet 25.02 B1 Water heater 37.52 Ai York Custom Mechanical Water piping/DWV 56.29 PO Box 21474 Other: 25.02 C' Keizer, OR 97307 Phone: 503-584-1771 Subtotal 4,1CCB: 203341 Plumbing: PB 1481 Minimum permit fee: $72.50 Plan review (25%of permit fee) Authorized signature: State surcharge(12%of permit fee) TOTAL PERMIT FEE Print name:CHAD ELLIO "��. �- Thispermit application ate:10/ /16 pp nation expires if a permit is not obtained within 180 days after it has been accepted as complete. *Fee methodology set by Tri-County Building Industry Service Board. I:\Building\Permits\PLMU-PermitApp.doc 10/01/09 440-4616T(10/02/COM/WEB) City of Tigard a COMMUNITY DEVELOPMENT DEPARTMENT II ■ TIGARD Building Permit Review — Residential Building Permit #: /VS 73)-42/C, --0 0 4<5 cy Site Address: 7 59 sk; 42,,,,,,e_ . . Project Name: ,t/� ii-iii-r/ 72x.kihappLe ( Lot #: (New dwelling=subdivision name;Addition or Alteration=last name of owner) Planning Review Proposal: ll,le. PL7- Verify site address/suite#exists and actio in permit system. fiver Terrace Neighborhood: No ❑ Yes,See River Terrace Review Addendum Attached Sit Plan Elements: I ree(3) copies of site plan 0 i• ting structures on site to plan must be on 8-1/2"x 11"or 11 x 17"paper.,,jT°# .p ,+, .t+rfnewtitructnre(including&do)with finidied Drawn to scale(standard architect or engineer scale)rk-- ei i ''5._V -' ,''o�`a w F0 P Utility locations(required for new,may apply for additions) !/ ite address,project or subdivision name and lot numbers' cation of wells/septic systems trikpplicant information(name and phone number) fisting trees to be retained with drip line,and tree Lot dimensions and building setback dimensions protection measures t as ' yq� G O >: prtl la?,eet tree size,type and location „. ���y���p �aami;ji � trip � +Mw �.�+,.� tRAO. i¢@ + Wka tt *» +N y 12,0^5 _ -,y�_ In /.. /1 t' I'I Street names G ✓r�(� , /� i iJurti P 4 +,i13; `+d t s(2 foot contour.linea if 013xt, skjkitiy1 a-- Ater\A J 0( lean Water Services—Service Provider Lett (lot platted prior to 9/10/1995): 'equired: ❑ Yes,applicant was notified V No Received: ❑ Yes ❑ No 1► Public Facilitiy Improvement(PFJ) Permit: Required: es,applicant was notified ❑ No Applied For: AA Yes ❑ No,stop intake Land Use Case#: a,et2OKS=f G1✓ IIZ/Zoning: 114ui2_ Q . VRequired Setbacks: Front AO Rear 0 Side C, Street Side AM Garage andscape Requirement: ,% Side:' �� toesf -vide Coverage Maximum: few 0 (Yo u Building Height: Maximum Height 44S Actual Height 0 1'Nisual Clearance ii,asements ensitive Lands: ❑ Yes RI/No Type r. Urban Forestry Plan ❑ Conditions "Met"prior to issuance of building permit 1 7 Notes: (?� /A �S'/a �' Ami.' /l>i±l/ 7L C')07.41 OP, . `/ 474f, i/eM eor eV"? / i/19/2C- . /0-6 / i�S �c c Approved By Planning: Date: /0 _ /8-16 ,..— Revisions (after Building Submittal only) Reviewer Date Revision 1: ❑ Approved ❑ Not Approved Revision 2: ❑ Approved ❑ Not Approved Revision 3: ❑ Approved ❑ Not Approved I:1Building\Forms131dgPermitRvw RES 091216.docx Building Permit Submittal Original Submittal Date: /dfr /(„, Site Plans: # Building Plans: # s Building Permit#: g'Enter building permit#above. Workflow Routing: [Planning ®`Engineering -hermit Coordinator Ehlfuilding Workflow Sign-off: 1E---Sign-off for Planning(include notes from planning review) Route Application Documents: [Engineering: (1) copy of permit application, (1) site plan, (1) building plan and original plan review routing form. Building: original permit application, site plans,building plans,engineer and beam calculations and trust details,if applicable,etc. Notes: /. Date: //�S. / By Permit Technician: .. r v _ Engineering Review i Slope at building pad: ■' Conditions "Met"prior to i suance of building permit 0 Easements (encroachments)per engineering conditions of approval and plat ❑ Water Quality/Quantity Facility: Assess Water Quality Fee in-lieu: ❑ Yes ❑ No Assess Water Quantity Fee in-lieu: ❑ Yes ❑ No LIDA Facility on lot: ❑ Yes ❑ No ❑ NOT Approv;d b, Engineering: Date: Notes: 4,. /_ fr .40 � ' r// cp Approved byEngineering: dz., Date: / ---i--1Z � �• Revisions (after Building Submittal only) Reviewer Date Revision 1: ❑ Approved ❑ Not Approved Revision 2: ❑ Approved ❑ Not Approved Revision 3: ❑ Approved ❑ Not Approved Permit Coordinator Review ❑ Conditions "Met"prior to issuance of building permit J Z:34Approved,NOT Released: Date: i i b�/l J otes: Revisions (after Building Submittal only) Revision Notice 1: Date Sent to Applicant: Revision Notice 2: Date Sent to Applicant: Revision Notice 3: Date Sent to Applicant: SDC Fees Entered: Wash Co Trans Dev Tax: Yes ❑ N/A Tigard Trans SDC: ti Yes ❑ N/A Parks SDC: Yes ❑ N/A '...FZCaK to Issue Permit Approvedby Permit Coordinator: /0Dat !e: „ I:\Build ng\Forms\BldgPermitRvw_RES_091216.docx City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 Location: Inspection Date: 8759 SW SPRUCE ST, TIGARD, OR, 97223 September 21 , 2018 at 10:51 :36 AM Record Type: Record ID: Residential - Master Permit MST2016-00459 Inspection Type: Inspector: 699 Mechanical final Aaron Cillo-Gobel Result: PASS Comments: Violation Summary: Inspector Contractor City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 Location: Inspection Date: 8759 SW SPRUCE ST, TIGARD, OR, 97223 September 27, 2018 at 10:59:45 AM Record Type: Record ID: Residential - Master Permit MST2016-00459 Inspection Type: Inspector: 199 Electrical final Chip Barnett Result: PASS Comments: Violation Summary: Inspector Contractor City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 Location: Inspection Date: 8759 SW SPRUCE ST, TIGARD, OR, 97223 October 30, 2018 at 9:34:57 AM Record Type: Record ID: Residential - Master Permit MST2016-00459 Inspection Type: Inspector: 299 Final inspection Aaron Cillo-Gobel Result: PASS - CofO Comments: Final erosion control passed Street tree certificate received Moisture content form received High efficiency lighting form received C of 0 left on counter. Violation Summary: Inspector Contractor