Report (74) Oregon Residential Specialty Code N1107.2
HIGH-EFFICIENCY INTERIOR LIGHTING SYSTEMS
Permit No.: MST2016-00148 Jurisdiction: Tigard
Site Address: 6810 SW Walnut Ter
Subdivision/Lot#: Parcel 2, Partition Plat No. 2013-010 in the City of Tigard, OR
and/or
Map and Tax Lot#: Tax ID# R2182797
By my signature below, I certify that a minimum of fifty (50) percent of the permanently
installed lighting fixtures in the above mentioned building have been installed with compact or
linear fluorescent, or a lighting source that has a minimum efficacy of 40 lumens per input watt.
(Oregon Residential Specialty Code N1107.2)1
•
Signature: Date: 2--(tY ( 7
OwiN, en al Qontractor/Authorized Agent
Print Name: Michael Vaughn
•
ORSC Section N1107.2. High-efficiency interior lighting systems. A minimum of fifty(50)percent o the
permanently installed lighting fixtures shall be installed with compact or linear fluorescent, or a lighting source that
has a minimum efficacy of 40 lumens per input watt. Screw-in compact fluorescent lamps comply with this
requirement.
The building official shall be notified in writing at the final inspection that a minimum of fifty percent of the
permanently installed lighting fixtures are compact or linear fluorescent,or a minimum efficacy of 40 lumens per
input watt.
I:\Building\Forms\RES-HighEfciencyLighting.doe 07/01/08
Oregon Residential Specialty Code R318.2
MOISTURE CONTENT ACKNOWLEDGEMENT FORM
I, Michael Vaughn , am the general contractor or the owner-builder
at the following address:
Site Address: 6810 SW Walnut Ter
City: Tigard
Permit#: MST2016-00148
Subdivision/Lot#: Parcel 2, Partition Plat No 2013-010 in the City of Tigard, OR
and/or
Map and Tax Lot#: Tax ID# R2182797
To conform with the 2008 Oregon Residential Specialty Code (ORSC), Section R318.2 and
OAR 918-480-0140, I am notifying the building official that I am aware of the moisture content
Requirement of ORSC Section R318.2 and have taken steps to meet this code requirement.
[Section R318.2 is provided for reference].
R318.2 Moisture Content: Prior to the installation of interior finishes, the building
official shall be notified in writing by the general contractor that all moisture-sensitive
wood framing members used in construction have a moisture content of not more than 19
percent by dry weight of dry framing members.
Signature: .r./ Date: Z-C/(G
General Contrac r or Owner-Builder
1:\Building\Form\RES-MoistureSensitiveWood.doc 09/25/08
• , '` :4'
•a
Jrin Climate Pro® A1000 Fiber_ Glass Blowing Wool
Your home has been profession--a-Ily-in-sul-atedto-p-r-ovide-s-uper-ior-ther-ma-1 resistan-ee. --
Homeowner's Name Date
Address C,?/O OA) 1, k(e
City IF State ZIP
RECORD INSTALLATION
BLOWING WOOL BATTS AND ROLLS
New Construction If Retrofit: R-VALUE THICKNESS AREA INSULATED
0
0 Retrofit • Depth of Previous Insulation in. Ceilings ,ein. sq.ft.
Number of bags used 7 3 Estimated R-value of Previous Installation in. sq.ft.
Area Insulated /f'74,0q.ft. Types of Previous Insulation in Attic Walls it°,.2./ in. sq.ft.
Thickness of Insulation/(p.a C in. in. sq.ft.
R-value of Insulation 11/ Floors ,(�3r in. sq.ft.
/` in. sq.ft.
CLIMATE PRO A1000 INSULATION
R-VALUE MINIMUM INSTALLED SETTLED THICKNESS MINIMUM WEIGHT BAGS PER MAXIMUM NET COVERAGE
(HR•SQ.FT.•°F/BTU) THICKNESS(IN.)* (IN.) PER UNIT AREA 1,000 SQ.FT. (SQ.FT./BAG)««
(POUNDS/SQ.FT.)
Installed insulation Expected thickness Weightper sq.ft.of
Minimum number of
To obtain insulation g q'ft
bags per 1,000 sq.ft. Contents of this bag shall
resistance(R)of:
less than: has occured: not be less than:shall not be after long-term settling installed insulation shall
of net area shall not not cover more than:
be less than:
13 4.75 4.75 - 0.180 5.5 182.9
19 6.75 6.75 0.266 8.1 124.2
22 7.75 7.75 0.311 9.4 106.3
26 9.00 9.00 0.368 11.2 89.6
30 10.25 10.25 0.428 13.0 77.0
38 12.75 / 12.75 0.555 16.8. 59.5
44 14.75 14.75 0.662 20.1 49.8
49 16.25 16.25 0.747 22.6 44.2
60 19.50 19.50 0.940 28.5 35.1
See reverse to determine adjustment in coverage for Climate Pro A1000 insulation in Minnesota.
'Determined using a Unisul Volu•Matic Ill blowing machine.The machine was set up in 3rd gear,with a 75%open gate and a 3'hose,blowing the wool out in a 10 ft.arc.
"Coverage without framing.
Insulation Contractor Signature / /i Date 9/506
Company -f-.4p, Da ) Lf/ ori Address 075$-paei c, d Phone 5,{ja-&,20-70a(0
Home Builder Signature Date
Company U. ,,y(, 0 rd 1L(' Address
Phone
!/ITJohnsManvjIIe