Loading...
Permit (196) CITY OF TIGARD SITE WORK PERMIT 1111 COMMUNITY DEVELOPMENT Permit#: SIT2016 00022 T[GARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 08/03/2017 Parcel: 1 S 135AD03400 Jurisdiction: Tigard Site address: 8701 SW SPRUCE ST Project: Hall Pointe Townhomes Subdivision: 1990-053 PARTITION PLAT Lot: 2 Project Description: Site work for(3)buildings containing(14)townhouse units,and(3)carport structures. Contractor: RICH DUNCAN CONSTRUCTION INC Owner: DAVIS, EUGENE REVOCABLE LIVING T 2295 RURAL AVE SE 10875 SW 89TH AVE SALEM, OR 97302 TIGARD, OR 97223 PHONE: 503-390-4999 PHONE: FAX: FEES Description Date Amount Specifics: Permit Fee-Site Work 08/03/2017 $777.14 Plan Review 11/07/2016 $505.14 Type of Use: COM 12%State Surcharge-Building 08/03/2017 $93.26 Class of Work: NEW Erosion Control w/Development 08/03/2017 $161.40 Info Process/Archiving-Lg$2.00(over 08/03/2017 $36.00 Project Valuation: $93,615.00 11x17) Site Specifics: Excavation Volume: 448 cu.yd. Fill Volume: 152.91 cu.yd. Impervious Surface: 25027 sq.ft. Engineered Fill: Soil Report Required: Paving: Grading: Yes Landscaping: Site Prep: Storn Drains: Retaining Wall: No Fire Underground: Accessible Parking: Fence: Total $1,572.94 Required Items and Reports(Conditions) This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: i(/ Permittee Signature: �rC //?. /-2 Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. ' `Building Permit Applicat +,I N V ��P � - Site Work FOR OFFICE USE ONLI i OCTCity of Tigard O1 rt Received III13125 SW Hall Blvd.,Tigard,OR 97223 t) PDate/By:lan Review."/� 3/ /a) • Permit No.: cji��lG--�0O9? II Phone: 503.718.2439 Fax: 5 a -p��'� ) 1 Other Permit: 677�apls DOQ'�S ;� Date/By: TI G A R D Inspection Line: 503.639.417A. s, z " ' •I Date Ready/By: / Juris: ® See Page 2 for Internet: www.tigard-or.gov is '1 _ z I d Dili' In P Notified/Method:d/ Supplemental information ��NJ 9it- 57 11-9,V,E TYPE OF WORK REQUIRED DATA:1-AND 2-FAMILY DWELLING 'New construction 0 Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ❑Addition/alteration/replacement 0 Other: equipment,materials,labor,overhead,and the profit for the CATEGORY OF CONSTRUCTIONwork indicated on this application. jl ❑ 1-and 2-family dwelling 0 Commercial/industrial Valuation: $ ❑Accessory building 0 Multi-family Number of bedrooms: ElMaster builder 0 Other: Number of bathrooms: — g7®/ JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address: -47-1-5-r5"" GT % 1 New dwelling area: square feet City/State/ZIP: .- ^-4 &- 010(("111. .> L_ ,, Garage/carport area: square feet Suite/bldg./apt.no.: Project name: t.1.CS. e N,YI\`�prrw' Covered porch area: square feet Cross street/directions to job site: S\1 Deck area: square feet Other structure area: square feet REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: Lot no.: Permit fees*are based on the value of the work performed. Tax map/parcel no.: Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. 00 1 ` SL C �ry�J�/1�9� Valuation: $ C‘ ) A s � �� n7$ Existing building area: square feet New building area: square feet IA PROPERTY.OWNER 0 TENANT Number of stories: Name: e V L% . -(- Type of construction: Address: d 2t0cti)° 0,ti - Occupancy groups: City/State/ZIP: - Existing: Phone:(963) 2 (a., IS L-, Fax:( f\ New: 9 APPLICANT 0 CONTACT PERSON NOTICE Business name: All contractors and subcontractors are required to be Contact name: C-c\4,9_ licensed with the Oregon Construction Contractors Board under ORS 701 and may be required to be licensed in the Address: *3) S (t`'•••Q. Z. jurisdiction in which work is being performed.If the City/State/ZIP: �+ 6S41730 3ery applicant is exempt from licensing,the following reasons a .n�- 1 d apply: Phone:(t,D31 S q,b-y CNC\Ql Fax::( ,O ) 'so..2 (e 3 3 E-mail: ASktIpa, • (.4)'Hr^ CONT:ACT4ncerzr.OR City/state/ZIP b7 3t Business name: Q,_ �y I� (fie X BUILDING PERMIT FEES* Address: 2 C`S Vtw` �/v`Q S\--:_-- (Please refer to fee schedule_) Structural plan review fee(or deposit): Phone:( ) 3 q B ,.1 Q c q Fax:( ) FLS plan review fee(if applicable): ` 5�33o Total fees due upon application: CCB lic.: A fNy/1Amount received: Authorized signature: J This permit application expires if a permit is nwithin 180 days after it has been accepted asPrint name: �,V\'f\ b �,,., 4 Date: k tij``3 k(Q * Fee methodology set by Tri-County Building In Service Board. I:\Building\Permits\SIT-PermitApp.doc 08/02/2016 440-4613T(11/02/COM/WEB) I City of Tigard: Site Work Permit Checklist Page 2-Supplemental Information Commercial,Multi-Family and One-and Two-Family Dwellings: No permit is required if fill is less than 50 yards(5 dump truck loads), or less than 3 feet deep and will not be supporting a structure. If a building will be constructed on the fill, it must be engineered fill. If fill is in a flood plain, drainage way,or wetland,the applicant must apply for a sensitive lands review (SLR). Please complete all items below,unless otherwise noted. Excavation Volume: cu.yds. Grading Volume: (Soils report required for>5,000 cu.yds.) cu.yds. Fill Volume: (Fill exceeding 12"in depth shall be compacted to 90%of maximum density) cu.yds. Retaining structure? (Check one) ❑ Rock ❑ CMU 7\)/1141- ❑ Concrete ❑ Other: *Total new impervious area including all buildings, sidewalks, and paving: sq. ft. Site Utilities Plumbing Work: Complete the Plumbing Permit Application for site utilities plumbing work. Plans Required: See"Site Work Permit Application-Plan Submittal Requirements"attached. The following must accompany this application: ❑ Site Plan with Vicinity Map showing ADA ❑ *Parking(including ADA)and Lighting compliance Plan ❑ Grading Plan and details ❑ *Landscaping Plan ❑ Erosion Control Plan and details ❑ Soils Report(if required) ❑ Retaining Structures *Does not apply to One-and Two-family dwellings. Plan Submittal: Permit Fee: TYPE OF SUBMITTAL #of Plans Valuation: Permit Fee (New,Additions or Required at $.00 to$500.00 $51.09 minimum permit fee Alterations) Submittal $500.01 to$2,000.00 $51.09 for the first$500.00 and $2.69 for each additional$100 or fraction Commercial 3 thereof,to and including$2,000.00. $2,000.01 to$25,000.00 $91.44 for the first$2,000.00 and Multi-Family R-1 Occupancy 3 $10.76 for each additional$1,000 or fraction thereof,to and including $25,000.00. One-&Two-Family Dwelling 3 $25,000.01 to$50,000.00 $338.92 for the first$25,000.00 and $8.06 for each additional$1,000.00 or fraction thereof,to and including $50,000.00. $50,001.00 to$100,000.00 $540.42 for the first$50,000.00 and $5.38 for each additional$1,000.00 or fraction thereof,to and including $100,000.00. $100,000.01 and over $809.42 for the first$100,000.00 and $4.49 for each additional$1,000.00 or fraction thereof. uilding\Permits\SIT-PermitApp.doc 08/02/2016 2 1 i 1 c-,/ (-) I `C; " OCC: cis`r City of Tigard: Site Work Permit Checklist Page 2-Supplemental Information Commercial,Multi-Family and One-and Two-Family Dwellings: No permit is required if fill is less than 50 yards(5 dump truck loads), or less than 3 feet deep and will not be supporting a structure. If a building will be constructed on the fill, it must be engineered fill. If fill is in a flood plain, drainage way, or wetland,the applicant must apply for a sensitive lands review (SLR). Please complete all items below, unless otherwise noted. Excavation Volume: ,r.0-- Grading Volume: .•) cu. ds. (Soils report required for>5,000 cu.yds.) 32 5.84u. Fill Volume: u.yds. (Fill exceeding 12"in depth shall be compacted to 90%of maximum density) Retaining structure? (Check one) • Rock Ai cu. ds. ❑ CMU l [2] Concrete i\ /Ir • *Total new impervious area including all buildings, Other: sidewalks, and paving: 2 52 027 0 c s•. ft. Site Utilities Plumbing Work: Complete the Plumbing Permit Application for site utilities plumbing work. Plans Required: See"Site Work Permit Application -Plan Submittal Requirements"attached. The following must accompany this application: ❑ Site Plan with Vicinity Map showing ADA 0 *Parking(including ADA)and Lighting compliance Plan El Grading Plan and details ■ Erosion Control Plan and details 0 Landscaping Plan • Retainin. Structures ❑ Soils Report(if required) *Does not apply to One-and Two-family dwellings. Plan Submittal: Permit Fee: TYPE OF SUBMITTAL #of Plans Valuation: (New,Additions or Re ��at Permit Fee: Alterations Q Commercial 5.00 to 5500.40 SS 1.09 minimum permit fee Submittal 5500.01 to$2,000.00 52,000.01 to 525,000.00 $51.09 for the first$500.00 and 3 $2.69 for each additional$100 or fraction thereof,to and including$2.000.00. $91.44 for the first$2,000.00 and Multi-Family R-I Occupancy 3 $10.76 for each additional 51,000 or fraction thereof,to and including One-&Two-Family Dwelling 3 $25,000.00. 525,000.01 to 550,000.00 5338.92 for the first$25,000.00 and $8.06 for each additional$1,000.00 or fraction thereof,to and including 550,000.00. 550,001.00 to$100,000.00 $540.42 for the first 550,000.00 and 1 55.38 for each additional$1,000.00 or fraction thereof.to and including $100,000.00. 5100.000.01 and over S809.42 for the first 5100,000.00 and $4.49 for each additional S1,000.00 or fraction thereof. I. Building',Pemiits SlT-PetrnitApp.doc 08 02,2016 2 IIICity of Tigard ■ COMMUNITY DEVELOPMENT DEPARTMENT T 1 G A R D Building Permit Review — Commercial - With Land Use Building Permit #: o / ra-O / 6, — ,,7c),c,,,9._.2-- Site Address: c ^C I SID gice ` i- Suite/Bldg#: Project Name: ,// J -7-z7,,,,,AOS (Name of commercial business occupying the space. If vacant,enter Spec Space.) Planning Review Proposal: j Zuor k.. ,CZ..e!)J? ir-- /Jj// / i;, v� s /yi-ia A ! / ,bu// .C [Verify site address/suite#exists and active in perrm /yste . '`�1 'ver Terrace Neighborhood: ❑ Yes I No Land Use Case#: ,gbEOIS= Cx 'Plans Match Approved Land Use: [Site Plan V Landscape Plan / 4 ther: Urban Forestry Plan elevation Plan f fJ 4':uilding Height: M um Height �s g �/ A Mr t J Actual Height / �U��r/_ C��/�vJ V. conditions Met: Prior to Submittal ❑ Prior to Permit Issuance K /� ®/Business Licen : i/ Exists: V Yes ❑ No,applicant notified to obtain business license Public Facilitie Improvement(PFI) Permit: Required: 101 Yes,applicant was notified ❑ No Applied For: 1/Yes ❑ No,stop intake Notes: (may ,. 4 . 't Approved by Planning: ,...► — .- T.yi1r Date: /0/-7777 Revisions (after Building Submittal only) Reviewer Date Revision 1: ❑ Approved ❑ Not Approved Revision 2: ❑ Approved ❑ Not Approved Revision 3: ❑ Approved ❑ Not Approved Building Permit Submittal / Original Submittal Date: 707/3/!4p Site Plans: # 3 Building Plans: # 3 Building Permit#: lav-Enter building permit#above. Workflow Routing: ilanning Engineering l-I ermit Coordinator D'Building Workflow Sign-off: iirSI off for Planning(include notes from planning review) Route Application Documents: Building: original permit application, sitelans,buildingplans,engineerand beam calculations and trust details,�jif applicable,etc. Notes: c,y�.L 4.0 ..-d1.2rn,,'ef -JYle e_ 64,06 X735', By Permit Technician: U ae �j_ ) Date: A? /1///'& I:\Building\Forms\BldgPermitRvw COM_WithLandUse 070915.docx Engineering Review Slope at building pad: /2, ,2 1-PFI Permit#: do. /d —tZi�6' Conditions "Met"prior to issuance of building permit ❑ Easements (encroachments)per engineering conditions of approval and plat(not typical on SDR/CUP) ❑ Water Quality/Quantity Facility: Assess Water Quality Fee in-lieu: ❑ Yes ❑ No Assess Water Quantity Fee in-lieu: ❑ Yes ❑ No LIDA Facility on lot: ❑ Yes 0 No 0 NOT Approv:, b Engineerin_: Date Notes: _ //..1r. i... s,-a 4.. .- -. - -- Approved by Engineering: WI ..8 Date: /'1--4/--A Revisions (after Building Submittal only) Reviewer Date Revision 1: 0 Approved ❑ Not Approved Revision 2: 0 Approved ❑ Not Approved Revision 3: 0 Approved ❑ Not Approved Permit Coordinator Review ❑ Conditions "Met"prior to issuance of building permit Zile,proved,NOT Released: le/If/Date: /1/9/40. Notes: r_ ,,1 ,,q4„ y`"' Revisions (after Building Submittal only) Revision Notice 1: Date Sent to Applicant: Revision Notice 2: Date Sent to Applicant: Revision Notice 3: Date Sent to Applicant: DC Fees Entered: Wash Co Trans Dev Tax: ❑ Yes /A (› Tigard Trans SDC: ❑ Yes N/A Parks SDC: ❑ YesN/A OK to Issue Permit Approved by Permit Coordinator: Date: -772 ?X. -- I:\Building\Forms\BldgPennitRvw_COM_WithLandUse l.-- I:\Building\Forms\B1dgPermitRvw_COM_WithLandUse 07091 5.docx PUBLIC FACILITY PLAN Project: SUB2016- Elderberry Ridge ■ COMPLETENESS CHECKLIST TIGARD GRADING ® Existing and proposed contours shown. SHOWN Does proposed grading impact adjacent parcels? ❑ Yes ® No NO IMPACT ❑ Adjacent parcel grades shown. NOT SHOWN STREET ISSUES ® Right-of-way clearly shown. SHOWN • Centerline of street(s) clearly shown. SHOWN ❑ Street name(s) shown. NOT ALL Existing/proposed curb or edge of pavement shown. SHOWN ❑ Street profiles shown. NO PROFILES Future street plan: Must show street profiles, topo on adjacent parcel(s), etc. NO FUTURE STREETS • Traffic impact report. HAVE REPORT ❑ Street grades compliant? NO PROFILES • Street widths dimensioned and appropriate. YES Private streets?Less than 6 lots and width appropriate? NO PRIVATE STREETS ❑ ENTER TEXT ENTER TEXT SANITARY SEWER ISSUES ® Existing/proposed lines shown. SHOWN ® Stubs to adjacent parcels required/shown? NOT SHOWN FOR 76TH WATER ISSUES ❑ Existing/proposed lines w/ sizes noted? NOT SIZED ❑ Existing/proposed fire hydrants shown? NO HYDRANTS ON PLAN REVISED: 2/1/2016 Page 1 of 2 / �► ❑ Proposed meter location and size shown? NOT SIZED ® Proposed fire protection system shown? NOT REQUIRED STORM DRAINAGE AND WATER QUALITY ISSUES ® Existing/proposed lines shown? YES Preliminary sizing calcs. For water YES quality/detention provided? Water quality/detention facility shown on TWO SHOWN plans? ® Facility shown outside and wetland buffer? YES ❑ Storm stubs to adjacent parcels NOT SHOWN required/shown? ENTER ANY ADDITIONAL TEXT HERE The submittal is hereby deemed ❑ Complete ® Incomplete By:Al Dickman,Senior Engineering Technician Date: 11/2/2016 REVISED: 2/1/2016 Page 2 of 2 City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 Location: Inspection Date: 8701 SW SPRUCE ST, TIGARD, OR, 97223 October 30, 2018 at 11 :35:23 AM Record Type: Record ID: Commercial - Site Work SIT2016-00022 Inspection Type: Inspector: 499 Final inspection Aaron Cillo-Gobel Result: PASS - NoCofO Comments: Violation Summary: Inspector Contractor