Loading...
Report (129) • M‘).-of? L 2- Se-cee r- OFFICE COPY Carrier cp United Technologies SUBMITTAL Proiect CycleBar TI - Greenway Town Center Submitted To Mill Creek Heating Date Monday, July 17, 2017 Submitted By Airefco, Inc. 18755 SW Teton Ave Tualatin OR 97062 (503)692-3210 Table Of Contents Project:CycleBar TI-Greenway Town Center 07/17/2017 Prepared By: 07:20AIV RTU-1 3 Unit Report 4 Certified Drawing 5 Performance Summary 9 RTU-2 12 Unit Report 13 Certified Drawing 14 Performance Summary 18 RTU-3 21 Unit Report 22 Certified Drawing 23 Performance Summary 27 Packaged Rooftop Builder 1.49 Page 2 of 29 • F RTU-1 Project:CycleBar TI-Greenway Town Center 07/17/2017 Prepared By: 07:20A111 RTU-1 Tag Cover Sheet Unit Report Certified Drawing Performance Report Packaged Rooftop Builder 1.49 Page 3 of 29 • Unit Report For RTU-1 Project:CycleBar TI-Greenway Town Center 07/17/2017 Prepared By: 07:20AIV Unit Parameters Dimensions(ft.in.)&Weight(lb.) Unit Model: 50KC-A06B2M5-6W1A0 Unit Length. 6'2.375" Unit Size. 06(5 Tons) Unit Width. 3'10.75" Volts-Phase-Hertz: 208-3-60 Unit Height: 3'5.375" Heating Type. None .,. Total Operating Weight: 753 lb Duct Cfg: Vertical Supply/Vertical Return Single Stage Compressor Models "" Weights and Dimensions are approximate. Weight does not include unit packaging. Approximate dimensions are provided primarily for shipping purposes. For exact dimensions and weights,refer to appropriate product data catalog. Lines and Filters Return Air Filter Type: Throwaway Return Air Filter Quantity. 4 Return Air Filter Size: 16 x 16 x 2 Unit Configuration RA Smoke Detector Medium Static Belt Drive Al/Cu-Al/Cu-Louvered Hail Guards Electromechanical Controls w/W7220 Econo Controller Enthalpy Ultra Low Leak Econo w/Baro Relief Unpowered Convenience Outlet Standard Packaging Warranty Information 5-Year compressor parts(STD.) 1-Year parts(STD.) No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 50KC-A06B2M5-6W1A0 Rooftop Unit 1 Base Unit RA Smoke Detector Medium Static Belt Drive Al/Cu-Al/Cu-Louvered Hail Guards Unpowered Convenience Outlet Ultra Low leak Enty Econo X with baro relief,W7220 control.Meets Calf.Title 24 FDD&Leak Rates Accessories --HH--57AC-081 Enthalpy Control for W7220 Controller 1 MM 0537-014A 14-inch Tall Roof Curb—Non-Calculated 1 MM 0406-0101 Hold Down Clips(set of 4) 1 HW TH8320R1003 Honeywell Vision Pro 8000 Thermostat 1 HW C7189R1004 Honeywell Wireless Indoor Air Sensor 1 Packaged Rooftop Builder 1.49 Page 4 of 29 Certified Drawing for RTU-1 ' Project: CycleBar TI-Greenway Town Center 07/17/2017 Prepared By: 07:20AN NOTES) UNITED P.O.1w""TIA�15 IpOCUK[�T IJ TIC PIDIEITT OT CcAIIIEA aw0NA�P1ORATIeyI�N1 SBWTIlI$ 11010 IWTA66 dl Yra 1.DIMENSIONS AA[[IN INpCHES DIMENSIONS TECHNOLOGIES 11000180.NT CAOHIII100)�,/,YELLY[IIpr SENOUC1e0Dge a CO l 0ITHOIT�Mini --Nor woi BTE. r PLIr RCL M IN[ ]AAE]N HILL I�ETEGS. UNIT J K ll PHASE) K 13 PHASE) CARRIER 12121 CgIPD11ATIg1 KRI71EN wAA08 Att[PrIRCLoc CONICACT. 7/8 2,St CENTER OF GRAVITY 508C 0/ [6117 11374 14 [311] CONNECTION SIZES SORG 05 33 3/8 1/7/8 18 5/8 3, DIRECTION OF AIR FLOW [8111 [3771 [172] A 1 318' [351 DIA FIELD POWER SUPPLY HOLE SON[06 11 3/8 IAN 18 5/8 8 2' 1511 DIA POWER SUPPLY KNOCKOUT 11D51] [3771 [/12] C 1 311' [ll]DIA GAUGE ACCESS PLUG 33-3/8 D 7/8. 1221 DIA FIELD CONTROL WIRING HOLE [8481 E 3//'-1/NPT CONDENSATE DRAIN MM 6 2 112' [611 DIA POWER SUPPLY KNOCK-OUT EONOAIDZAL)HO , 6 14D81 FIL7EA ACCESS PANEL THAU-THE-BASE CHART 1TOOL-LESS) COMP I THESE HOLES REQUIRED FOR USE 'PANEL 1 CONDENSER —— t CT SIZEMR001 A01 COIL THREADED WIRE REO'D HOLE INDOOR COIL j;; - - - - - CONDUIT SIZE USE SIZES I AIJ ACCESS PANEL '� 25-5/8 —.' W 1/2' ACC. 7/6' [22.2] " hr �� [652] 10-718 0 112' 240 7/8" [22.2] MO. IIII�� ��•Al • RETURN AIR 1277] RETURN Y Sll' 1001) POWER 1 I/O" [28.11 I6/N)��T♦�� �iP]£l IU� 1®//�I AIR FOR'THAU-TNF-BASFPAMKT N'FACTORY OPTION. /1 \� /%�� - I ' FITTINGS F ROVIDED 16 Y ARE BACK ANDLE 2-518—1 111111 9 [67] \ E ALT.J I SELECT EITHER 3//'OA 1/2' . CONDENSATE I 28-3/8 FOR POWER. DEPENDING ON WIRE SIZE CUP nW -DRAIN OPENING - [717] R IN°ASEPAN CURB 17-3// WIDTH ..Y [151] SUPPLY SUPPLY • 28-1/2 16-1/6 f AIR [673] AIR [4111 SEE THRU THE 18-1/8 14-1/4 12-1/4 I BASE CHARTL___L__ 5 11581 [3631 [3121 1 • 6- 11 1 A 3-3/8 S 1851 [6 -12-1/8— it K . ...... 32-1/4— [307] [8181 TOP 18-1/2--[470] — [16512 [110] 1-111 1-5/8 [321 [118] r` _21.11.;; IDE _ III LECTRICAL — CONTROL BOA INDOOR BLOWER E STD, COIL -- DISCONNECT ACCESS PANEL ACCESS CONDENSATE LOCATION _ DRAIN 25-11d I 0 OPTIONAL _ A J i- — 1638] '' AIRSIDE 18-3// RETURN FAC70RY , 18-1/2 OPTIONAL—'d-°L—— I U271 AIR INSTALLED [/f/] FACTORY 12861° SUPPLY AIR 3-3/I CONVENIENCE 1:1=.=.= =- INSTALLED • [95] I OUTLET -I 11 6.51E D[SCON�ECT �J J P. —I_ n f_ [53911 _8�= =�� 116d] , Cl00 ~C1: 00 i�ss HANDLE HANDLE) 6-5/8 7 6 [160] [1771 [1521 16-3/4 26-7/8 [1187] 1662] BAROMETRIC [16881 F O LEFT RELIEF 31-1/4 SUPPLY 11837 FRONT AIR RETURN RIGHT SHEET BATE w10800002 50KC 04-06 SINGLE ZONE ELECTRICAL REY 1042 09-16-14 - COOLING WITH ELECTRIC HEAT 48KC000282 _ Packaged RooftopBuilder 1.49 Page 5 of 29 9 Certified Drawing for RTU-1 Project: CycleBar TI-Greenway Town Center 07/17/2017 Prepared By: 07:20AN, UNITED P.O.DOD MM ID NAlIMH(I 10 tlTIE PITT OF COHIllIED [OpR�PllpMrrip�[R �)K[ON p[TOW 1141031 O ECCIAG,HTTS STD. UNIT CANER CORNER CORNER CORNER C.G. HEIGHT TECHNOLOGIES M OSE,NT CdRjn I;/Ll INT 6E DtagpO[O M Df[O iTnMDtf�CAa/I[I S ROT,.'TIktlF aPAPIAli^`C UNIT *EIGHT *EIGHT IA) WEIGHT(5) *EIGHT(C) *EIGHT ID) t000111��EIPPMMAnOI s IRm[y agt[Nr. [ 1 LBS. KG, LBS. K6. LBS. K6. LBS, K6. LBS. K6, I T Z 50KC 04 445 201 127 51 104 47 97 44 118 53 33 1/2 03511 22 1/2 15111 19 311 15011 50KC 05 499 226 140 63 118 53 110 50 130 59 34 1/8 18661 22 1/2 15711 19 314 16011 50KC 06 552 250 143 65 149 67 133 60 12T 57 38[9651 22 15591 20 374 15271 •STANDARD UNIT WEIGHT IS WITHOUT ELECTRIC HEAT AND WITHOUT PACKAGING. FOR OTHER OPTIONS AND ACCESSORIES. REFER TO THE PRODUCT DATA CATALOG. CORNER A CORNER B •o • • • • . Illlllllll�/_ rl�, CORNER D CORNER C TOP U. • • Z • 1 O 0 .�'�. �t�J: : 00 FRONT MET DATE 3SPEOCECEO 50KC 04-06 SINGLE ZONE ELECTRICAL REO 20E2 09-16-14 - COOLING WITH ELECTRIC HEAT 48KC000282 _ Packaged Rooftop Builder 1.49 Page 6 of 29 • Certified Drawing for RTU-1 Project: CycleBar TI-Greenway Town Center 07/17/2017 Prepared By: 07:20AIV Service Clearance C \ \ --- I 1. < -------- ~ •` A '`---> \ \,` /.--. LOZATION DIMENSION CON01—ION 484n(1719 mmt •Vint nicrt wit i;mmntarl nr,penal .4 18-in(457 mm) •No dlscxnect,coiwene,ce OJtlet option •Recammcnded 52niteccanna 124n(305mm) •Nirimum dearance 42-n(1067 mmd •Su•faro'Jett rid stir neer Is gr waled(e.g.,rnela1 meatier well; a 36-in(914 mm) •Sauce ash nd servicer is clattrfallr rr►:onductiw(c.g.,wood,6berg asst Special •Checktar;ourcasague products v1thin 10-tt.otunit freshet Intake hood 36-In(914mm) •Side condensate drain Is used V 18-in(457mm) •Minimum clearance Own(1219 mml •No flue discharge accessoryiretafei,surfa:eis co mbrsoble matenat 42-in 1007 mml •Suface behind serecer b gnunied(e.g.,metal,nsasoiry arall,anther unit) D 36-In 914 min) •Surface behind miner Is alectrcatty nun-conductive(e.g.,wood,fiberglass) Spevtd •::heck for adjacent units cc bu Wing kegler mtaoes vetted au-ft of two units flue outlet NOTei Mt not d?dgned to haw nvvr ieai nbctnatinn CnntartAapliratinn Fngimwring fnr gnidame nn any anal mon panning overhead obstrictior or veroral cleararces. CUM 1-2 Packaged Rooftop Builder 1.49 Page 7 of 29 SUBMITTAL PA MicroMetl No Units Selected Part Number: 0537-014A-00010 FORM NO. 1174-1D I 2/11/2014 Submitted To: Company: Job Name: Notes Opening for thru 1 3/4"Alt.drain hole the bottom electrical connections Knockdown Curbs ` Blocked top / 3 11 corners NOTES: Full Perimeter �♦ deApi Rt4 r 4 2011 • *Custom Heights Are Available. • *Fully Insulated Perimeter Curbs Are Available And Supply1 air7/ ' Designated With A"CrSuffix. • *Hold Down Brackets Are Available For Most Curbs. • Attach Ductwork Directly To Roof Curb.Flanges Of Duct 67 3/8 1 3/4"-11.1 I ' 37 /16" Rest On Top Of Curb. I ' • Any Posted Weight Is Actual Weight,Not Shipping Weightr 1, • All Dividers&Supports If Present,Are Flush With Top Of f-- .1 Curb Unless Noted. A "Please Contact Factory For Pricing and Availability CROSS SECTION FEATURES: OF CURB • Ships Knockdown,Assembly Hardware Provided When Needed. • Deck Pans When Factory Provided,Are Factory Insulated. • Constructed Of Galvanized Steel. 0537 Series Roofcurb Specifications (in inches) • Gasketing Package Provided. MicroMetl Part No. Carrier Part No. A Weight • Full Perimeter Wood Nailer Provided. 0537-008A-00010 8" 71 lbs 0537-011A-00010 11" 82 lbs 0537-014A-00010 CRRFCURB001A02 14" 94 lbs 0537-018A-00010 18" 0537-024A-00010 CRRFCURB002A02 24" 131 lbs CU-2D • THIS DOCUMENT IS THE PROPERTY OF MICROMETL CORPORATION AND IS DELIVERED UPON THE EXPRESS CONDITION THAT THE CONTENTS WILL NOT BE DISCLOSED OR USED WITHOUT MIROMETL'S WRITTEN CONSENT MicroMetl Corporation... Indianapolis Indiana — 1-800-662-4822, Sparks Nevada— 1-800-884-4662, Longview Texas— 1-903-248-4800 a I ce I n I 0 n 2 2 _ 1 _ n S i _ DOWN 90° R.035 _ 8 1 0 0 0 0 D D D D z cn0 N o v ern 74 N N mio RI — co d N A 0 w _ UP 90°R.035 _ J 414--t>./ a 01 — UP 78° R.035 y - — — D > D D O O 0 0 c 1 D oc Z (n 4 V O O O 9. OD N N = m x NMI C A A O 0 O O \--------- W W0 0 O O N /0 y\ N 0406-0101 — (4) KC597EMH PER KIT • 24 MicroMetl Corporation MATERIAL DRAWN BY REV ECO DESCRIPTION DATE CHG APPR Innanawiia,IN.:(800)662-4822-Sparks,NV.(boo)884-4662 16-GA NB Longview,TX.(903)248-4800 PART NUMBER SIZE WEIGHT(6) DESIGNED BY ' KC597EMH A N/A NB THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE (DO NOT SCALE DRAWING) TOLERANCES ARE: PART DESCRIPTION SHEET CHECKED BY PROPERTY OF MICROMETL CORPORATION.ANY REPRODUCTION UNLESS OTHERWISE 2013 KD HOLD DOWN 1 OF 1 IR IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF SPECIFIED ±1/32" , ±0.031", ±2° MICROMETL CORPORATION.IS PROHIBITED. DIMENSIONS ARE IN INCHES y Ico I C) I 0 REV A-1 o Performance Summary For RTU-1 Project:CycleBar TI-Greenway Town Center 07/17/2017 Prepared By: 07:20AN Part Number:50KC-A06B2M5-6W1A0 ARI SEER- 14.10 Base Unit Dimensions Unit Length- 74.4 in Unit Width: 46.8 in Unit Height: 41.4 in Operating Weight Base Unit Weight: 552 lb RA Smoke Detector: 5 lb Medium Static Belt Drive: 10 lb Al/Cu-Al/Cu-Louvered Hail Guards: 16 lb Enthalpy Ultra Low Leak Econo w/Baro Relief: 50 lb Unpowered Convenience Outlet: 5 lb Accessories 14-inch Tall Roof Curb: 115 lb Total Operating Weight: 753 lb Unit Unit Voltage-Phase-Hertz: 208-3-60 Air Discharge. Vertical Fan Drive Type- Belt Actual Airflow: 2000 CFM Site Altitude: 39 ft Cooling Performance Condenser Entering Air DB: 95.0 F Evaporator Entering Air DB: 80.0 F Evaporator Entering Air WB: 67.0 F Entering Air Enthalpy: 31.46 BTU/lb Evaporator Leaving Air DB- 58.6 F Evaporator Leaving Air WB: 57.3 F Evaporator Leaving Air Enthalpy. 24.58 BTU/Ib Gross Cooling Capacity: 61.82 MBH Gross Sensible Capacity: 46.17 MBH Compressor Power Input: 5.19 kW Coil Bypass Factor: 0.058 Supply Fan External Static Pressure- 0.75 in wg Options/Accessories Static Pressure Economizer 0.12 in wg Total Application Static(ESP+Unit Opts/Acc.): 0.87 in wg Fan RPM: 1258 Fan Power 1.45 BHP NOTE: Selected IFM RPM Range: 1035-1466 Electrical Data Voltage Range: 187-253 Compressor#1 RLA. 15.9 Compressor#1 LRA. 110 Outdoor Fan Motor Qty: 1 Outdoor Fan FLA(ea): 1.4 Indoor Fan Motor Type- MED Indoor Fan Motor FLA: 8.4 Power Supply MCA: 30 Power Supply MOCP(Fuse or HACR)• 45 Disconnect Size FLA- 30 Packaged Rooftop Builder 1.49 Page 9 of 29 • , , Performance Summary For RTU-1 Project:CycleBar TI-Greenway Town Center 07/17/2017 Prepared By: 07:20AIV Disconnect Size LRA: 185 Electrical Convenience Outlet: None Control Panel SCCR:5kA RMS at Rated Symmetrical Voltage Acoustics Sound Power Levels,db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz 89.5 88.7 87.5 125 Hz 83.1 79.7 82.5 250 Hz 75.5 67.4 76.1 500 Hz 72.8 65.4 73.6 1000 Hz 72.1 67.2 71.3 2000 Hz 67.1 61.8 67.1 4000 Hz 68.8 57.8 64.1 8000 Hz 65.5 50.9 60.0 A-Weighted 77.5 71.6 77.0 Advanced Acoustics Iii _._ mt I e 0 .,,,, -= - itik Cc kiii, , 0 6 Advanced Accoustics Parameters 1. Unit height above ground: 30.0 ft 2. Horizontal distance from unit to receiver: 50.0 ft 3. Receiver height above ground: 5.7 ft 4. Height of obstruction: 0.0 ft 5. Horizontal distance from obstruction to receiver: 0.0 ft 6. Horizontal distance from unit to obstruction: 0.0 ft Detailed Acoustics Information Octave Band Center Freq.Hz 63 125 250 500 1k 2k 4k 8k Overall A 87.5 82.5 76.1 73.6 71.3.67.1 64.1 60.0 89.2 Lw B 61.3 66.4 67.5 70.4 71.3 68.3 65.1 58.9 76.7 LwA C 55.1 50.1 43.7 41.2 38.9 34.7 31.7 27.6 56.8 Lp D 28.9 34.0 35.1 38.0 38.9 35.9 32.7 26.5 44.3 LpA Legend A Sound Power Levels at Unit's Acoustic Center, Lw B A-Weighted Sound Power Levels at Unit's Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp D A-Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Packaged Rooftop Builder 1.49 Page 10 of 29 Performance Summary For RTU-1 Project:CycleBar TI-Greenway Town Center 07/17/2017 Prepared By: 07:20AIV Calculation methods used in this program are patterned after the ASHRAE Guide;other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space,an Acoustical Engineer or a person with sound prediction expertise should be consulted. Fan Curve 2.0 00 PM \ 1300 PPM\ 1500 RPM \ \ u 1700 RPM 1.8 \ \ 1• RPM \ \ \ \ \ 1.4 Bu0 ii';' \ \ \ _.. _ I\ e1.2 \ \ \ \ \ y1.0NN ‘ \ d 700 RPM \ \ 00.8 \ \ 1 \ \ 1 C RHP (4 \ \2.00 BHP 0.6 \ _ \ \\1.50: P \ 500 RPM 0.4 _ OO RHP O.\ BHP 0.2 0.0 -' I I I 11 1 1 \ 1 1 \ 1 1 1 1 II II 0.0 0.3 0.6 0.9 1.2 1.5 1.8 2.1 2.4 2.7 3.0 3.3 Airflow(CFM-thousands) RPM=1258 BHP=1.45 Maximum RPM=2100 Maximum BHP=2.90 Note:Please contact application engineering for selections outside the shaded region. SC-System Curve RP-Rated Point Packaged Rooftop Builder 1.49 Page 11 of 29 RTU-2 Project:CycleBar TI-Greenway Town Center 07/17/2017 Prepared By: 07:20AN RTU-2 Tag Cover Sheet Unit Report Certified Drawing Performance Report Packaged Rooftop Builder 1.49 Page 12 of 29 Unit Report For RTU-2 Project:CycleBar TI-Greenway Town Center 07/17/2017 Prepared By: 07:20AN Unit Parameters Dimensions(ft.in.)&Weight(1b.)*** Unit Model: 48TCED08B2M5-6W1A0 Unit Length. 7'4.125" Unit Size• 08(7.5 Tons) Unit Width. 4'11.5" Volts-Phase-Hertz: 208-3-60 Unit Height: 3'5.25" Heating Type- Gas •** Total Operating Weight: 1126 lb Duct Cfg: Vertical Supply/Vertical Return Medium Heat *** Weights and Dimensions are approximate. Weight Round Tube Plate Fin Coils does not include unit packaging. Approximate dimensions are provided primarily for shipping purposes. For exact dimensions and weights,refer to appropriate product data catalog. Lines and Filters Gas Line Size: 3/4 Condensate Drain Line Size: 3/4 Return Air Filter Type: Throwaway Return Air Filter Quantity. 4 Return Air Filter Size: 16 x 20 x 2 Unit Configuration RA Smoke Detector Medium Static Option(Belt Drive) Al/Cu-Al/Cu-Louvered Hail Guards Electromechanical Controls w/W7220 Econo Controller Enthalpy Ultra Low Leak Econo w/Baro Relief Unpowered Convenience Outlet Standard Packaging Warranty Information 1-Year parts(std.) 5-Year compressor parts(std.) 10-Year heat exchanger-Aluminized(std.) No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 48TCED08B2M5-6W1A0 Rooftop Unit 1 Base Unit RA Smoke Detector Medium Static Option(Belt Drive) Al/Cu-Al/Cu-Louvered Hail Guards Unpowered Convenience Outlet Ultra Low leak Enty Econo X with baro relief,W7220 control.Meets Calf.Title 24 FDD&Leak Rates None Accessories --HH--57AC-081 Enthalpy Control for W7220 Controller 1 MM 0597-014A 14-inch Tall Roof Curb—Non-Calculated 1 MM 0406-0101 Hold Down Clips(set of 4) 1 HW TH8320R1003 Honeywell Vision Pro 8000 Thermostat 1 HW C7189R1004 Honeywell Wireless Indoor Air Sensor 1 Packaged Rooftop Builder 1.49 Page 13 of 29 Certified Drawing for RTU-2 Project:CycleBar TI-Greenway Town Center 07/17/2017 Prepared By: 07:20AN NOTES: UNITED P.O.REX 1000 TX IS DOCWFNi IS INF PRWfRTY Of CARRIER CORPWATEYR UNIT OUTDOOR U N H TECHNOLOGIES SYRACUSE.NY ANO IS DELIYEREO UPON THE ERPRESS CONDITION TNAT INE SD MSSHOT OF THESE DRAPINGS OR ASNET OR I. DIMENSIONS ARE IN INCHES, DIMENSIONS COIL TYPE CONTENTS NI LL NOT R[DISCLOSED OA USCD TITXWI CARRIER MOT CONST Iitlif P Ai PFRfWYAXt[OR IN[ ] ARE IN MILLIMETERS. 41 1/d 33 15 1/8 CARRIER row CWPRRATION'S TUITION CONSENT, ACCEPTANCE 00 DWTRHCT, 48TC-A08 RIPE [10481 [658] 1/03] 2. CENTER OF GRAVITY 49 3/8 37 I/1 27 7/8 CONNECTION SIZES 48TC-A09 RIPE [12531 1946] [708] 3,y DIRECTION OF AIR FLOW /9 3/8 3[7 1 1/8 A 1 3/8' [35] DIA FIELD POWER SUPPLY HOLE 48TC-Al2 RIPE 40-3/8 [1253] [946]/1 [15 1031 [10261 1 B 2 1/2" [641 DIA POWER SUPPLY KNOCKOUT 1/ 33 15 C 13/4' (51]DIA GAUGE ACCESS PLUG 481C-D08 ROPE [111048]I 1 ,1 1101 ,c8 [40371/8 48TC-D09 ROPE 19 3/8 37 1// 15 1/B D 7/8" [22]DIA FIELD CONTROL WIRING HOLE 11253] [9461 14031 48TC-D12 ROPE d9 3/8 37 1// 15 7/B ECONOMIZER HOOD [52 i1/ E 3/4"-I4 NPT CONDENSATE DRAIN 11253] [9461 [1031 (OPTIONAL) - F 1/2'-14 NPT GAS CONNECTION 11 1/t 33 23 3/4"-14 NPT GAS CONNECTION 48TC-008 MCH% 110481 16581 [581,2] J G 2 ' [511 DIA POWER SUPPLY KNOCK-OUT 48TC-D12 MCH% 49 3/8 37 1/4 11 112531 [916] tris.41 s THRU-THE-BASE CHART (FIELD INST) RIPE -ROUND TUBE, PLATE FIN(COPPER/ALUM) THESE HOLES REQUIRED FOR USE WITH ACCP KITS: MCH%-NOVATION IALUN/ALUM • 1 • /��l � 1 36-3/8 12-5/B ♦ CRBTMPWROO4A01:GAS TARS BASEPAN • /� I [URN] [321] II / I RETURN AIR RETURN 11\\ !VI/ — t I AIR THREADED WIRE REO'D HOLE �i�� o CONDUIT SIZE USE SIZES IMA%.1 � �� W I/2" ACC. 7/8" [22.21 FILTER ACCESS PANEL MOB' E ALT % I/2" 24V T/8" [22.21 • (TOOL-LESS) _ CONDENSATE Y 1 1/4' (002,0041 POWER 1 3/4' [44.41 /� \,DRAIN OPENING 28-3/1 • CONDENSER �� IN BASEPAN 2 P 1001)3/4'FPT GAS 13/4' [41.41 • COIL [7311 37.5/8 10-3/8 IW SUPPLY [9551 [1021] • M IR l\ / /0 I SEE THRU AIR (0021 PROVIDES 3/4'FPT THRU CURB INDOOR COIL % SUPPLY R ACCESS PANEL ..-_--,--;,/ Y THE BASE AIR FLANGE 6 FITTING. HOLE SIZE:2' [50,8] • BACK 6 e ��\Q j�II CHART • I:.11. 11551 I1 =-� _ THRU-THE-BASE CHART (FIOP1 [2 TBI _ I FOR'THRU-THE-BASEPAN"FACTORY OPTION. 10(5 I f 1 � _.--- -- N., _- FITTINGS FOR ONLY X. Y. 6 Z ARE PROVIDED. RR FOR BELOW LISTED MODELS, A FIELD 6-1/4 SUPPLIED 1/2"ADAPTER IS REQUIRED 29-5/8—•., 4 LUE ►--3.1/4 [159] 'R BETWEEN BASE PAN FITTING AND GAS VALVE: [751] [1001 HOOD 14 F 1831 48NCD,SR08 [356] TOP ,F-25-1/2—.., All [6471 H 1-1/4 4-5/8 [321 I1-7/8 [302] [1161 • A - -.. .I��I I DISCONNECT FILTER II DISCONNECT ACCCESSLPANEL E STD. CONDENSER B, LOCATION CONDENSATE COIL G DRAIN OPTIONAL11' INDOOR BLOWER •I _ M. OPTIONAL •' U FACTORY ACCESS _ FACTORY INSTALLED 27-7/8 DISCONNECT 27- // I OUTSIDE INSTALLED I [1091 AIR CONVENIENCE II. F HANDLE • 13-1/8 [706] • 26 OUTLET C C. [3311 - SUPPLY AIR \ [6591 II HANDLETh [� I � II 6-5/8 y 6-1/8 •. I_—_I 1108] 8 r' ,=,. - =.-,===, ,•-•- i 1 ��C) � �� bO y [157] �IIT_ � l 3-3/4 2-5/8 6-5/8 1 t 4-3/8 [951 59-1/2 [611 8-3/8 [167] [1771 6-1/8 [15101 [6P 37 12141 37-7/8 [1551 (1131 [9401 [9621 CURB 42-3/8 LEFT WIDTH 88-1/8 [10151 4 BAROMETRIC [2238] SUPPLYRETURN RELIEF AIR AIR FLOW FRONT RIGHT MET DATE SUPERCEDES 48TC 08-12 SINGLE ZONE ELECTRICAL REV 48TM500985 1 OF2 03-08-10 11-24-08 COOLING WITH GAS HEAT F Packaged Rooftop Builder 1.49 Page 14 of 29 Certified Drawing for RTU-2 Project: CycleBar TI-Greenway Town Center 07/17/2017 Prepared By: 07:20AN UNITED P.O.AOR Ime TRES DOCUMENT IS IRE PROPERLY OF CARRIER CORPORATION SUAMISSION OF THESE DRANINDS OR DOCUMENTS TECHNOLOGIES SYRACUSE.NY AND IS DELIVERED UPON THE EXPRESS CONDITION THAT INE DOES NOT CONSTITUTE PART PERFORMANCE OR STD, UNIT CORNER CORNER CORNER CORNEA CARRIER NJtUT 'COATPMALION 5 K�0949 CONSENT,OR USED IITHOUT CARRIER ACCEPTANCE OF CONTRACT, UNIT OUTDOOR WEIGHT RRR WEIGHT IA) WEIGHT IB/ WEIGHT(C) WEIGHT ID) C.G. COIL TYPE 0LBS. KG. LBS. KG, LOS. KG. LBS. KG. LBS. KG. X 1 Z 48TC-A08 RIPE 180 354 178 81 158 72 209 95 236 107 41 1/2[10541 33 7/8 1860] 20 1/2[5211 •••STANDARD UNIT WEIGHT IS WITH LOW GAS HEAT AND WITHOUT PACKAGING. 48TC-A09 RTPF 920 418 212 96 183 83 243 110 282 128 40 1/8[1038] 34[8611 23 1/8[5871 FOR OTHER OPTIONS AND ACCESSORIES. REFER TO THE PRODUCT DATA CATALOG. 48TC-Al2 RIPE 930 422 216 98 196 89 247 112 272 123.5 42 110671 33 1/8[841] 24 1/4[6161 48TC-508 RIPE 835 379 164 14.5 170 77.2 255 115.8 246 111.7 44 7/8 111401 35 5/8[905] 19 3/8[4921 481C-D09 RTPF 930 422 228 103.5 187 85 232 105.3 283 128,5 39 3/4 110101 32 7/8[8351 18 5/8 14731 48TC-D12 RTPF 940 427 231 104.9 189 85.8 231 106.2 286 129.8 39 3/4 110101 33 1838] 18 1/2 14701 48TC-008 MCHX 805 365.5 160 72,6 153 69.5 240 109 260 118 43 110921 36 3/8 09241 20 3/8 1517.71 48TC-112 SCAB 895 106.3 185 84 176 19.9 260 118 274 124,1 42 7/8 110891 35 1/2 19021 22 7/8[5811 RTPF -ROUND TUBE. PLATE FIN(COPPER/ALUM) CORNER A CORNER B MCNX -NOVATION(ALUM/ALUMI ) pn , Y II ,;7', ! • 1 11 7/.1110 I CORNER D I CORNER C TOP X • 2 - 1 boo i . . ,�. : © ooh FRONT SHEET DATE SUPERCEDES 48TC 08-12 SINGLE ZONE ELECTRICAL REV 2OF2 03-08-10 11-24-08 COOLING WITH GAS HEAT 48TM500985 F - Packaged Rooftop Builder 1.49 Page 15 of 29 Certified Drawing for RTU-2 Project: CycleBar TI-Greenway Town Center 07/17/2017 - Prepared By: 07:20AN Service Clearance C --.,d i sem', A utta, LOCATION. DIMENSION C01101'I08 4E1-in(1219 mmi •JIM ascomect Is mounted on pate' 364n(914 rrrn) •,.tdfaensWu-B 612ir(305 rum: 'A 1R-in(457 mm) •No discxwn nact,convert ortiat option •Recrmmen6ed seM_e c earence lose eletrk screwdlver. 124n(NZ nm) •Nirimun desrence:use mend ratchet screwdriver) 364n(914 mm) •Unit has'canon zer S 1G-in(3td mm) •?f dimension-A is'..'b- (314 m711 Special •:heck for sources of flue products wit/8110-ft of wilt fresh air intake hood 164n(914 mm) •Side condensate drain is used 18-in(4b/nun) •Mlremtm clearance 48-in(1219 mmi •No flue discharge accessoryinstald,surfa.a is combustible materiel 47.In(11167 mml •;I rfara behind grruirxk grsmied(a.g_,moral,naacmry:vat anther unit) ) 36-in(914mm) •Strface behind seracere elearcally non-conductive(e.g..wood.fiberglass) Spacial -:heck for adfecent units or bu IcIrg fresh Mr Hayes wthin 10-ft of the unit's flae outlet NOTE:Unit nut designed lo have tver rea l ulnlr utiuL CudautAaplhation Erghteedrg fur guide ite un any opal cat on planning overhead obstrxtior or vertical eieararcos. Ovssx 5-4a Packaged Rooftop Builder 1.49 Page 16 of 29 SUBMITTAL MicroMetl Part Number: 0597-014A-00010 FORM NO. 1282-1D I 2/19/2014 Submitted To: Locator piece Company: Opening for thru Ink AInmc• the bottom electrical 1 3/4"Alt.drain hole connections Knockdown Curbs %lip Full Perimeter . ,,, ,0 1/16" NOTES: \1 Rete • *Custom Heights Are Available. ./‹ .• *Fully Insulated Perimeter Curbs Are Available And 15 11/16" �/ Designated With A"CI"Suffix. Supply air • *Hold Down Brackets Are Available For Most Curbs. 7 1/4" • Attach Ductwork Directly To Roof Curb.Flanges Of Duct Rest On Top Of Curb. 0 • Any Posted Weight Is Actual Weight,Not Shipping Weight • All Dividers&Supports If Present,Are Flush With Top Of 47 Curb Unless Noted. 1 3/4"—ol I allT *Please Contact Factory For Pricing and Availability f If1 1 FEATURES: A • Ships Knockdown,Assembly Hardware Provided When CROSS SECTION Needed. OF CURB • Deck Pans When Factory Provided,Are Factory Insulated. • Constructed Of Galvanized Steel. —0.-II 2" kii- 0597 Series Roofcurb • Gasketing Package Provided. Specifications • Full Perimeter Wood Nailer Provided. MicroMeti Part No. Carrier Part No. A Weight 0597-008A-00010 8" 84 lbs 0597-011A-00010 11" 105 lbs 0597-014A-00010 CRRFCURB003A01 14" 126 lbs 0597-018A-00010 18" 163 lbs 0597-024A-00010 CRRFCURB004A01 24" 193 lbs CU-2D _ THIS DOCUMENT IS THE PROPERTY OF MICROMETL CORPORATION AND IS DELIVERED UPON THE EXPRESS CONDITION THAT THE CONTENTS WILL NOT BE DISCLOSED OR USED WITHOUT MIROMETL'S WRITTEN CONSENT MicroMetl Corporation... Indianapolis Indiana–1-800-662-4822,Sparks Nevada–1-800-884-4662,Longview Texas–1-903-248-4800 n I W I O I v t a 6. Oo "i co a 1 co P. ,000 i DOWN 90 o. _ — ° R.035 1 O O O O II D D D D z II 0' V O 1 � G V y N V _mo — 1 o N m _ UP 90°R.035 _ Jii--ii:).-al N D D _ UP 78"R.035 _ — C) D > > D D 0 0 0 0 c II D m Z 1 Cr V (li O O St O —I m x C A A ll\ \--------: \0 O O 0W W O 0 O 0 N0\ N i B 0406-0101 — (4) KC597EMH PER KIT • 22 MicroMetl Corporation MATERIAL DRAWN BY REV ECO DESCRIPTION DATE CHG APPR InaanawI+s.I9:(800)662-4922--Sparks.NV.(800)684-4662 16-GA NB (.OnOVIaw,TX.(903)248-4800 . _ PART NUMBER SIZE WEIGHT(N) DESIGNED BY KC597EMH A N/A NB THE INFORMATION CONTAINED IN THIS DRAVNNG IS THE SOLE (DO NOT SCALE DRAWING) TOLERANCES ARE PART DESCRIPTION SHEET CHECKED BY PROPERTY OF MICROMETL CORPORATION.ANY REPRODUCTION UNLESS OTHERWISE 2013 KD HOLD DOWN 1 OF 1 IR IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF SPECIFIED ±1/32 ", ±0.031", ±2° MICROMETL CORPORATION.IS PROHIBITED. DIMENSIONS ARE IN INCHES > I w -i O i 0 REV A-1 i 1 Performance Summary For RTU-2 Project:CycleBar TI-Greenway Town Center 07/17/2017 Prepared By: 07:20AIv Part Number:48TCEDO8B2M5-6W1AO ARI EER: 11.00 IEER: 11.7 Base Unit Dimensions Unit Length- 88.1 in Unit Width: 59.5 in Unit Height: 41.3 in Operating Weight Base Unit Weight: 835 lb Medium Heat 15 lb RA Smoke Detector: 5 lb Medium Static Option(Belt Drive): 15 lb Al/Cu-Al/Cu-Louvered Hail Guards: 34 lb Enthalpy Ultra Low Leak Econo w/Baro Relief: 74 lb Unpowered Convenience Outlet: 5 lb Accessories 14-inch Tall Roof Curb: 143 lb Total Operating Weight:- 1126 lb Unit Unit Voltage-Phase-Hertz: 208-3-60 Air Discharge. Vertical Fan Drive Type• Belt Actual Airflow: 3000 CFM Site Altitude. 39 ft Cooling Performance Condenser Entering Air DB: 95.0 F Evaporator Entering Air DB: 80.0 F Evaporator Entering Air WB: 67.0 F Entering Air Enthalpy: 31.46 BTU/lb Evaporator Leaving Air DB• 58.7 F Evaporator Leaving Air WB: 57.6 F Evaporator Leaving Air Enthalpy 24.78 BTU/lb Gross Cooling Capacity: 90.07 MBH Gross Sensible Capacity 68.81 MBH Compressor Power Input: 6.40 kW Coil Bypass Factor: 0.092 Heating Performance Heating Airflow: 3000 CFM Entering Air Temp: 60.0 F Leaving Air Temp: 105.7 F Gas Heating Input Capacity: 120.0/180.0 MBH Gas Heating Output Capacity: 98.0/148.0 MBH Temperature Rise: 45.7 F Thermal Efficiency(%): 82.0 Supply Fan External Static Pressure. 0.75 in wg Options/Accessories Static Pressure Economizer 0.11 in wg Total Application Static(ESP+ Unit Opts/Acc.)• 0.86 in wg Fan RPM: 833 Fan Power 2.04 BHP NOTE: Selected IFM RPM Range:733-949 Packaged Rooftop Builder 1.49 Page 18 of 29 Performance Summary For RTU-2 Project:CycleBar TI-Greenway Town Center 07/17/2017 Prepared By: 07:20AN Electrical Data Voltage Range: 187-253 Compressor#1 RLA• 13.6 Compressor#1 LRA• 83 Compressor#2 RLA• 13.6 Compressor#2 LRA• 83 Indoor Fan Motor Type• MED Indoor Fan Motor FLA: 8.4 Combustion Fan Motor FLA(ea)• 0.48 Power Supply MCA: 42 Power Supply MOCP(Fuse or HACR)• 50 Disconnect Size FLA• 44 Disconnect Size LRA: 246 Electrical Convenience Outlet: None Outdoor Fan[Qty/FLA(ea)]: 2/1.5 Control Panel SCCR:5kA RMS at Rated Symmetrical Voltage Acoustics Sound Power Levels,db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz 98.8 95.9 85.8 125 Hz 91.9 87.1 84.3 250 Hz 79.1 75.1 80.5 500 Hz 71.6 67.4 78.7 1000 Hz 68.6 64.7 76.4 2000 Hz 67.4 59.7 72.7 4000 Hz 68.6 59.3 68.3 8000 Hz 71.6 58.7 65.1 A-Weighted 80.4 75.4 82.0 Advanced Acoustics Q _ -- i'401 -71.111116._ 0 144 u S 4Q 4 Sk Si Advanced Accoustics Parameters 1. Unit height above ground: 30.0 ft 2. Horizontal distance from unit to receiver: 50.0 ft 3. Receiver height above ground: 5.7 ft 4. Height of obstruction: 0.0 ft 5. Horizontal distance from obstruction to receiver: 0.0 ft 6. Horizontal distance from unit to obstruction: 0.0 ft Detailed Acoustics Information Packaged Rooftop Builder 1.49 Page 19 of 29 , Performance Summary For RTU-2 Project:CycleBar TI-Greenway Town Center 07/17/2017 Prepared By: 07:20A1V Octave Band Center Freq.Hz 63 125 250 500 1k _ 2k 4k 8k Overall A 85.8 84.3 80.5 78.7 76.4 72.7 68.3 65.1 89.6 Lw B 59.6 68.2 71.9 75.5 76.4 73.9 69.3 64.0 81.4 LwA C 53.4 51.9 48.1 46.344.040.335.932.757.2Lp D 27.2 35.8 39.5 43.1 44.0 41.5 36.9 31.6 49.0 LpA Legend A Sound Power Levels at Unit's Acoustic Center, Lw B A-Weighted Sound Power Levels at Unit's Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp D A-Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Calculation methods used in this program are patterned after the ASHRAE Guide;other ASHRAE Publications and the AHRI Acousti cal Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space,an Acoustical Engineer or a person with sound prediction expertise should be consulted. Fan Curve 2.0 00 RPM 1000 RPM 1100 RP'M\ 1 .0 RPM - 800 RPM \ `,,,,, \ \ \ 1.4 N 3 - 700 RPM \ \ \ v1.2� a ii ' N. co 1.0 -0 RPM- ------ \ N \ \.. Q. mos \ \ 500 RPM ' - \ 0.6 \ 400 RPM 0.4 N \ 3.00 B • - N. \ 2.84 BHP 0.2 1.50 BHP\( \'.uulmr \ - 0.50 BH 75 BHP \ 0.0 11 I 1 1 1 I I I I I I 1 '1.. 1 \I. I I l I 1 �I I I I 0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 4.4 Airflow(CFM-thousands) RPM=833 BHP=2.04 Maximum RPM=1400 Maximum BHP=4.70 Note:Please contact application engineering for selections outside the shaded region. SC-System Curve RP-Rated Point Packaged Rooftop Builder 1.49 Page 20 of 29 RTU-3 Project:CycleBar TI-Greenway Town Center 07/17/201 Prepared By: 07:20AN RTU-3 Tag Cover Sheet Unit Report Certified Drawing Performance Report Packaged Rooftop Builder 1.49 Page 21 of 29 Unit Report For RTU-3 Project:CycleBar TI-Greenway Town Center 07/17/2017 Prepared By: 07:20AW Unit Parameters Dimensions(ft.in.)&Weight(lb.)*** Unit Model: 48TCED08B2M5-6W1A0 Unit Length- 7'4.125" Unit Size. 08(7.5 Tons) Unit Width- 4'11.5" Volts-Phase-Hertz: 208-3-60 Unit Height: 3'5.25" Heating Type. Gas *— Total Operating Weight: 1126 lb Duct Cfg: Vertical Supply/Vertical Return Medium Heat *** Weights and Dimensions are approximate. Weight Round Tube Plate Fin Coils does not include unit packaging. Approximate dimensions are provided primarily for shipping purposes. For exact dimensions and weights,refer to appropriate product data catalog. Lines and Filters Gas Line Size. 3/4 Condensate Drain Line Size: 3/4 Return Air Filter Type: Throwaway Return Air Filter Quantity. 4 Return Air Filter Size: 16 x 20 x 2 Unit Configuration RA Smoke Detector Medium Static Option(Belt Drive) Al/Cu-Al/Cu-Louvered Hail Guards Electromechanical Controls w/W7220 Econo Controller Enthalpy Ultra Low Leak Econo w/Baro Relief Unpowered Convenience Outlet Standard Packaging Warranty Information 1-Year parts(std.) 5-Year compressor parts(std.) 10-Year heat exchanger-Aluminized(std.) No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 48TCED08B2M5-6W1A0 Rooftop Unit 1 Base Unit RA Smoke Detector Medium Static Option(Belt Drive) Al/Cu-Al/Cu-Louvered Hail Guards Unpowered Convenience Outlet Ultra Low leak Enty Econo X with baro relief,W7220 control.Meets Calf.Title 24 FDD&Leak Rates None Accessories --HH--57AC-081 Enthalpy Control for W7220 Controller 1 MM 0597-014A 14-inch Tall Roof Curb—Non-Calculated 1 MM 0406-0101 Hold Down Clips(set of 4) 1 HW TH8320R1003 Honeywell Vision Pro 8000 Thermostat 1 HW C7189R1004 Honeywell Wireless Indoor Air Sensor 1 Packaged Rooftop Builder 1.49 Page 22 of 29 Certified Drawing for RTU-3 - Project: CycleBar TI-Greenway Town Center 07/17/2017 - Prepared By: 07:20AN NOTES: UNITED PO.000 IROS THIS 00081(81[S TNf PROP[Ril Of CARRIER COMPO 11011 OUTDOOR AND IS DELIVERED UPON THE EXPRESS CONDITION TNA7 TM SURMIS51O1 OF THESE URANIN65 OR 0000MEN15 1, DIMENSIONS AAE IN INCHES. DIMENSIONS UNIT COIL TYPE 3 N H CARRIER OM 5r2uusE.NY CONTENTS MILL 801 RL 015CLOSID OR USED NITN0U1 CARRIER Wf5 NOTA0045511110OPART P(RrT�,YANOS OR [OAPOAAT ION'S NRI iTEN CONS[N1, IN[ ]ARE [N MILLIMETERS. 41 1/4 33 15 7/8 48TC-608 RTPF [1048] [6581 [4031 2. CENTER OF GRAVITY 49 3/8 37 1/4 27 1/8 CONNECTION SIZES 48TC-A09 RTPF 11253] [9461 17081 3.y DIRECTION OF AIR FLOW !9 3/8 3[1916/14 0[5 1/8 A 1 3/8' [35] DIA FIELD POWER SUPPLY HOLE 48TC-Al2 RTPF I•' —/003/8 y [12531 [946] [1031 I [1026] B 2 1/2' [641 DIA POWER SUPPLY KNOCKOUT /8TC-D08 RTPF 11 1/d 33 15 1/8 I C 1 3/4• [51]DIA GAUGE ACCESS PLUG [10461 [6581 [103] , 48TC-D09 RTPF 48 3/8 37 1/4 15 3/8 D 7/8' 1227 DIA FIELD CONTROL WIRING HOLE [12531 19161 [1031 49 3/B 37 1// 15 7/8 ECONOMIZER HOOD 20-3/d E 3//•-1/RFT CONDENSATE DRAIN 48TC-D12 RTPF [527] 1/2'-11 NPT GAS CONNECTION [12531 [916] [103] •4 (OPTIONAL) • F 3/4'-14 NPT GAS CONNECTION 48TC-D08 MCH% 41 1/4 33 23 110481 16581 [584.2] G 2' [51]DIA POWER SUPPLY KNOCK-OUT 48TC-D12 NCH% 49 3/8 37 1/4 11 N [12531 1946] [279.41 -i THRU-THE-BASE CHART (FIELD INST) RTPF-ROUND TUBE, PLATE FIN(COPPER/ALUM) THESE HOLES REQUIRED FOR USE WITH ACCP KITS: •MCH%-NOVATION(ALUM/ALUM) • /�� CABTMPWRDOZA01�GAS THRU CURB /��%�� [ 36-3/8 12-5/8 CRBTMPWROOIA01;GAS THRU BASEPAN • III [925] [3211 IN RETURN AIR RETURN 1 / �� 1-, I 6[R THREADED WIRE REO'D HOLE V . J� LN CONDUIT SIZE USE SIZES(MA%.I �� W 1/2" ACC, 7/8" [22,21 FILTER ACCESS PANEL _ I % 1/2" 24V 7/8" [22.2] (TOOL-LESS) ',„•-%-'------'7----7"."' E ALT, 1 Y 1 1/4' (002,0041 POWER 1 3/4• [44.41 CONDENSATE 14,---5:7-=--„ DRAIN OPENING CONDENSER 1 \ [N BASEPAN I 28-3/4 Z 1 10041 3/d'FPT GAS 1 3/4' [d/.d] / COIL INl ‘, \1 [7311 395518 1182/8 W SUPPLY [955] [1027] I • SEE THRU AIR SUPPLY (002)PROVIDES 3/4' FPT THRU CURB- INDOOR COIL THE BASE AIR R FLANGE 4 FITTING. HOLE SIZE: 2" [50.8] ACCESS PANEL -• 'L -„///IY CHART BACK [a69]1e a �� 2 11 4121 [3SSI tt k I THRU-THE-BASE CHART (FIOP( [2,91 Y } 1 1 FOR'THRU-THE-BASEPAN'FACTORY OPTION. (AU - `�' '� �)�'•' 1 >� 1 1 FITTINGS FOR ONLY 0, Y, 4 Z ARE PROVIDED. RR 1 • r FOR BELOW LISTED MODELS, A FIELD L 6-1/4 SUPPLIED 1/2'ADAPTER IS REQUIRED 4 [159] R' BETWEEN BASE PAN FITTING AND GAS VALVE: [9-1/8—~ 1100] HOOD LUE — f 3-1/4 48HCD.SR08 —.+ 14 1831 TOP 3s61 25-1/2—,.. 6471 H -1/4 [321 11-7/8 4-5/8 13021 [118] -_ DISCONNECT BOX • I FILTER `III DISCONNECT ACCESSPANELE STD. • CONDENSER 9, LOCATION CONDENSATE • COIL G 1---Y DRAIN IOPTIONAL) INDOOR BLOWER Imo_ MO' OPTIONAL •• U FACTORY ACCESS _____FACTORY INSTALLED OUTSIDE .411 27-7/8 DISCONNECT 27-3/d INSTALLED N [7091 AIR CONVENIENCEU �� F l� HANDLE 13-1/8 '' [706] ,I hi. 26OUTLET C 6 II- Ln [3341 SUPPLY AIR / [659] HANDLE--.t=3 - c ( 6-5/8 1 — 8 =}ER 116BI 00 I I u '1' 'I' : : OOitsn -- 3-3/4 L- 6-5/8 i [951 59-1/2 2-5/8— -8-3/8 [167] [1171 6-1/84 t/-3/8 11510] [57] 37 12141 37-7/8 11551 [1131 TIP1940] [962] CURB 4-3/ LEFT WIDTH F. 88-1/8 [10758 ilk BAROMETRIC [2238] SUPPLYRETURN RRELIELIEF AIR FRONT RIGHT SKEET DATE SUPERCEDES 48TC 08-12 SINGLE ZONE ELECTRICAL REV 48TM500985 1 OF 2 03-08-10 11-24-08 COOLING WITH GAS HEAT F Packaged Rooftop Builder 1.49 Page 23 of 29 Certified Drawing for RTU-3 Project:CycleBar TI-Greenway Town Center 07/17/2017 Prepared By: 07:20AN UNITED P.O.BOB 4500 10(5 DOCUMENT ES THE PROPERTY OF CARRIER CORPORATION SUBMISSION OF T.000 DRAR(N05 OR pOCDNE810 TECHNOLWIES STRACUSE.NY fart UELIYE5ED 0PON TRE EXPRESS CONDITION LNAI THE DOES NOL CONSTPART 05 05 5ANCE OR STD. UNIT CORNER CORNER CORNER CORNER CARRIER 13221 COAPEONAAI[01�3%A ITIEN CONSEMiD OR 00(0 WI10001 CARRIER ACCCPTANC[OE CONTRACT. UNIT OUTDOOR WEIGHT eee WEIGHT(Al WEIGHT(B) WEIGHT(C1 WEIGHT(D) C.G. COIL TYPE LBS. KG. LBS. KG. LBS. KG, LBS. KG. LBS. KG. X Y Z 48TC-A08 RIPE 780 354 178 81 158 72 209 95 236 107 41 1/2[1054] 33 7/8[8601 20 1/2[5211 550 STANDARD UNIT WEIGHT IS WITH LOW GAS HEAT AND WITHOUT PACKAGING. 480C-809 RTPF 920 418 212 96 183 83 243 110 282 128 40 7/8[1038] 34[8641 23 1/8[5871 FOR OTHER OPTIONS AND ACCESSORIES, REFER TO THE PRODUCT DATA CATALOG. 480C-Al2 RIPE 930 422 216 98 196 89 247 112 272 123.5 42[10671 33 1/8[8411 24 1/4[6161 4800-D08 _ RTPE 835 319 164 74.5 170 17.2 255 115.8 246 111.7 44 7/8[1140] 35 5/8 19051 19 3/8[492] 4801-009 RTPF 930 422 228 103.5 187 85 232 105.3 283 128.5 39 3/4[10101 32 7/8[8351 18 5/8[473] 480C-D)2 RTPF 940 427 231 _104.9 189 85.8 234 106.2 286 129.8 39 3/4[1010] 33[8381 18 1/2[470] 4811-008 BOX 805 365.5 160 72.6 153 69,5 240 109 260 118 43[10921 36 3/8[9241 20 3/8[517.7] 48TC-D12 MCHX 895 406.3 185 84 176 79.9 260 118 214 124.4 42 7/8[10891 35 1/2 [902] 22 7/8[5811 RIPE -ROUND TUBE, PLATE FIN(COPPER/ALUM) CORNER A CORNER B MCHX-NOVATION (ALUM/ALUM) 1 - r\1 71 i . , \ ,>,___.•(,,,/, / N.- 7--.7.---,-:% / IIIf iI r t 141,11t1' l r.liir S • CORNER D Li CORNER C TOP X - =1) A z 1I. o ' _ I OO O : : c0 FRONT SHEET DATE SUPERCEDES 48TC 08-12 SINGLE ZONE ELECTRICAL REY 48TM500985 2OF2 03-08-10 11-24-08 COOLING WITH GAS HEAT F Packaged Rooftop Builder 1.49 Page 24 of 29 Certified Drawing for RTU-3 Project: CycleBar T1-Greenway Town Center 07/17/2017 T Prepared By: 07:20AN Service Clearance C �\ rte, ,s �'�� , l r/ �` . . - ,fes ./ ..'-,.-, t A / �.� .fy ~ \� /- y � 111241 LOCATION DIMENSION CON01-1011 48-in(1219 mml •Unit dammed it mounted or,patel 36-in(914 nen) •71N•rremiun-9 is 12-ti(305 mm' A 111-in(157mm) •No disc enact,corven env outlet option •Repmmended soM_ecearance;use eletricscrewdriver: 12-in(305 nm) •Mirirnun desrance,use manual ratchet saewdrher) 36-In(914 mm) •Unit has ec roil ter 3 52-in(30 mm) •Idimenscn-A IS Sb-in(514 mill Special •Check fors rices of flue pcducts within 10-ft 3f utit fresh air intake hood 36-in(914 min) •iiia condensate drain is used win(4b/Ren) •Minion clearance 48-in(1219 mint •No file discharge aeeessoryinstaled,surfa=e is combustible material 42-in(11167 mmi •'extern behind ceritrer is grirmind(p.g.,mnrd,macmry wall,on'Nhwr unit) D 30-In(914nMn) •suface behind servlcer6 clear alk/non-conductive(e.g..wed.flberplasr_) Spade •:heck for adjacent units or Wieling fresh Mrknees wthin 10-ft cf th s unit's flare outlet NOTE;Uril nut designed lu have over'mai ubstr ultiul CurilaiAuplisatiun Engin urir g fix guithrice on any opal colon plarning overhead obstrictior or vertical cicararces. ours 3-4i Packaged Rooftop Builder 1.49 Page 25 of 29 SUBMITTAL =micrometi Part Number: 0597-014A-00010 FORM NO. 1282-1D I 2/19/2014 Submitted To: Locator piece Company: Opening for thru / 1 34"Alt.drain hole the bottom electrical Ink Mme• connections Knockdown Curbs 1 ' �� Full Perimeter :' 11r 40 1/16" NOTES: '4et4, 0 • *Custom Heights Are Available. • *Fully Insulated Perimeter Curbs Are Available And 15 11/16" �/ Designated With A"CI"Suffix. Supply air I'm - • *Hold Down Brackets Are Available For Most Curbs. 7 1!4" • Attach Ductwork Directly To Roof Curb.Flanges Of Duct �. Rest On Top Of Curb. .4, 50'7". • Any Posted Weight Is Actual Weight,Not Shipping Weight • All Dividers&Supports If Present,Are Flush With Top Of Curb Unless Noted. 1 3!4"-11 I —f— *Please Contact Factory For Pricing and Availability N 1 FEATURES: A • Ships Knockdown,Assembly Hardware Provided When4__ CROSS SECTION Needed. OF CURB • Deck Pans When Factory Provided,Are Factory Insulated. • Constructed Of Galvanized Steel. 2 • Gasketing Package Provided. 0597 Series Roofcurb Specifications • Full Perimeter Wood Nailer Provided. MicroMetl Part No. Carrier Part No. A Weight 0597-008A-00010 8" 84 lbs 0597-011A-00010 11" 105 lbs 0597-014A-00010 CRRFCURB003A01 14" 126 lbs 0597-018A-00010 18" 163 lbs 0597-024A-00010 CRRFCURB004A01 24" 193 lbs CU-2D - THIS DOCUMENT IS THE PROPERTY OF MICROMETL CORPORATION AND IS DELIVERED UPON THE EXPRESS CONDITION THAT THE CONTENTS WILL NOT BE DISCLOSED OR USED WITHOUT MIROMETL'S WRITTEN CONSENT MicroMetl Corporation... Indianapolis Indiana—1-800-662-4822,Sparks Nevada—1-800-884-4662, Longview Texas—1-903-248-4800 D I co I 0 I :o>nf Oo - Oo I. 2 _ _ _i a , _ DOWN 90°R.035 8 O O OI� D D D V , JI L.IcnO G V yt --- — � N y 43 V iS O f0 _ N j w — UP 90°_R.035 — g a /44 °" > D — UP 78T R.035 _ D > D D D 0 0 0 0 C D m 2 1 :-1 (n O1.1 O 9 0 co N —I m x xl c A 4.- 0 0 0 111111111---------: W WC0 0 0 0 N `\ N 0406-0101 _ (4) KC597EMH PER KIT °A MicroMetl Corporation MATERIAL DRAWN BY REV ECO DESCRIPTION DATE CHG APPR Indianapolis.N.:(boo)662-4822--Sparks,Nv.(ea*884-4662 16-GA NB Loma/raw.TX.(903)248-4800 PART NUMBER SIZE WEIGHT(b) DESIGNED BY I KC597EMH A N/A NB THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE (DO NOT SCALE DRAWING) TOLERANCES ARE: PART DESCRIPTION SHEET CHECKED BY PROPERTY OF MICROMETL CORPORATION.ANY REPRODUCTION UNLESS OTHERWISE 2013 KD HOLD DOWN 1 OF 1 IR IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF SPECIFIED ±1/32", ±0.031", ±2° MICROMETL CORPORATION.IS PROHIBITED. DIMENSIONS ARE IN INCHES D I W I n I 0 REV A-1 6 ,8 , f Y Performance Summary For RTU-3 Project:CycleBar TI-Greenway Town Center 07/17/2017 Prepared By: 07:20AN Part Number:48TCEDO8B2M5-6W1A0 ARI EER: 11.00 IEER• 11.7 Base Unit Dimensions Unit Length. 88.1 in Unit Width: 59.5 in Unit Height: 41.3 in Operating Weight Base Unit Weight: 835 lb Medium Heat- 15 lb RA Smoke Detector: 5 lb Medium Static Option(Belt Drive): 15 lb Al/Cu-Al/Cu-Louvered Hail Guards: 34 lb Enthalpy Ultra Low Leak Econo w/Baro Relief: 74 lb Unpowered Convenience Outlet: 5 lb Accessories 14-inch Tall Roof Curb: 143 lb Total Operating Weight: 1126 lb Unit Unit Voltage-Phase-Hertz: 208-3-60 Air Discharge- Vertical Fan Drive Type• Belt Actual Airflow: 3000 CFM Site Altitude- 39 ft Cooling Performance Condenser Entering Air DB: 95.0 F Evaporator Entering Air DB: 80.0 F Evaporator Entering Air WB: 67.0 F Entering Air Enthalpy: 31.47 BTU/Ib Evaporator Leaving Air DB• 58.7 F Evaporator Leaving Air WB: 57.6 F Evaporator Leaving Air Enthalpy 24.79 BTU/Ib Gross Cooling Capacity: 90.09 MBH Gross Sensible Capacity. 68.79 MBH Compressor Power Input: 6.40 kW Coil Bypass Factor: 0.092 Heating Performance Heating Airflow: 3000 CFM Entering Air Temp: 60.0 F Leaving Air Temp: 105.7 F Gas Heating Input Capacity: 120.0/180.0 MBH Gas Heating Output Capacity: 98.0/148.0 MBH Temperature Rise: 45.7 F Thermal Efficiency(%): 82.0 Supply Fan External Static Pressure. 0.75 in wg Options/Accessories Static Pressure Economizer. 0.11 in wg Total Application Static(ESP+Unit Opts/Acc.)- 0.86 in wg Fan RPM: 833 Fan Power 2.04 BHP NOTE: Selected IFM RPM Range:733-949 Packaged Rooftop Builder 1.49 Page 27 of 29 Performance Summary For RTU-3 Project:CycleBar TI-Greenway Town Center 07/17/2017 Prepared By: 07:20AN Electrical Data Voltage Range: 187-253 Compressor#1 RLA• 13.6 Compressor#1 LRA• 83 Compressor#2 RLA• 13.6 Compressor#2 LRA• 83 Indoor Fan Motor Type• MED Indoor Fan Motor FLA: 8.4 Combustion Fan Motor FLA(ea)• 0.48 Power Supply MCA: 42 Power Supply MOCP(Fuse or HACR)• 50 Disconnect Size FLA• 44 Disconnect Size LRA: 246 Electrical Convenience Outlet: None Outdoor Fan [Qty/FLA(ea)]: 2/1.5 Control Panel SCCR:5kA RMS at Rated Symmetrical Voltage Acoustics Sound Power Levels,db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz 98.8 95.9 85.8 125 Hz 91.9 87.1 84.3 250 Hz 79.1 75.1 80.5 500 Hz 71.6 67.4 78.7 1000 Hz 68.6 64.7 76.4 2000 Hz 67.4 59.7 72.7 4000 Hz 68.6 59.3 68.3 8000 Hz 71.6 58.7 65.1 A-Weighted 80.4 75.4 82.0 Advanced Acoustics t Ni 0 ,1s,: Si _ i ,,,1-- 0 i :,-- •410 Ski 0 0 1441 Advanced Accoustics Parameters 1. Unit height above ground: 30.0 ft 2. Horizontal distance from unit to receiver: 50.0 ft 3. Receiver height above ground: 5.7 ft 4. Height of obstruction: 0.0 ft 5. Horizontal distance from obstruction to receiver: 0.0 ft 6. Horizontal distance from unit to obstruction: 0.0 ft Detailed Acoustics Information Packaged Rooftop Builder 1.49 Page 28 of 29 Performance Summary For RTU-3 Project:CycleBar TI-Greenway Town Center 07/17/2017 Prepared By: 07:20A1V Octave Band Center Freq.Hz 63 125 250 500 1k 2k 4k 8k Overall A 85.8 84.3 80.5 78.7 76.4 72.7 68.3 65.1 89.6 Lw B 59.6 68.2 71.9 75.5 76.4 73.9 69.3 64.0 81.4 LwA C 53.4 51.9 48.1 46.3 44.0 40.3 35.9 32.7 57.2 Lp D 27.2 35.8 39.5 43.1 44.0 41.5 36.9 31.6 49.0 LpA Legend A Sound Power Levels at Unit's Acoustic Center, Lw B A-Weighted Sound Power Levels at Unit's Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp D A-Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Calculation methods used in this program are patterned after the ASHRAE Guide;other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space,an Acoustical Engineer or a person with sound prediction expertise should be consulted. Fan Curve 2.0 9Q RPM 1000 RPM 1100 RPM\ 1 60 RPM 1.8 800 RPM 1.6 1.4 3 - 700 RPM \ \ ti0 . 105 RPM- \ \ 00.8 ca \� co 50 RPM \ \ \ \ 0.6 \ \ 400 RPM 0.4 N \ \ 3.00 B • 0.2 \ 2.4e BHP \ 1.50 BHP\ \ 7.w bHr \ 0.50 BH V 75 BHP 0.0 III II I III III I '1. 1 Y I I i l \I I\ I 0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 4.4 Airflow(CFM-thousands) RPM=833 BHP=2.04 Maximum RPM= 1400 Maximum BHP=4.70 Note:Please contact application engineering for selections outside the shaded region. SC-System Curve RP-Rated Point Packaged Rooftop Builder 1.49 Page 29 of 29