Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report (117)
/14 7/2-z 5 £,Ioo 22,„7 �Fkr covi RECEIVED Carrier ,JUL 1 7 2017 CITY OF TIGARD BUILDING DIVISION SUBMITTAL Project -UntitledI Date Wednesday, May 10, 2017 Project: -Untitled1 05/10/2017 Prepared By: 06:28AM 2ton 3 Unit Report 4 Certified Drawing 5 Performance Summary 6 Unit Feature Sheet Spec Sheet 9 3 ton 10 11 Unit Report 12 Certified Drawing 13 Performance Summary 16 Unit Feature Sheet Spec Sheet 19 5 ton 20 21 Unit Report 22 Certified Drawing 23 Performance Summary 26 Unit Feature Sheet 29 Spec Sheet 30 6 ton 31 Unit Report 32 Certified Drawing 33 Performance Summary 39 Unit Feature Sheet Table Of Contents Spec Sheet 42 43 Packaged Rooftop Builder 1.46 Page 2 of 43 2ton Project: - 05/ 0/201 Prepared By: Untitled1 0/6:28AM 1 7 2ton Tag Cover Sheet Unit Report Certified Drawing Performance Report Unit Feature Sheet Spec Sheet Packaged Rooftop Builder 1.46 Page 3 of 43 Unit Report For 2ton Project: —Untitled1 05/10/2017 Prepared By: 06:28AM Unit Parameters Dimensions(ft. in.)&Weight(lb.)*** Unit Model. 48VL-C240403 Unit Length. 4'0.1875" Unit Size. 24(2.0 Tons) Unit Width. 2'8.625" Volts-Phase-Hertz 230-1-60 Unit Height 3'7.75" Heating Type. Gas ••• Weights and Dimensions are approximate.Weight does not include roof Duct Cfg. Vertical Supply/Vertical Return curbs,unit packaging,field installed accessories or factory 40,000 Btuh installed options. Approximate dimensions are provided primarily for Standard Unit shipping purposes.For exact dimensions and weights,refer to appropriate product data catalog. Total Operating Weight 304 lb Warranty Information 1 year warranty on parts 5 year warranty on compressor 5 year warranty on heat exchanger No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 48VL-C240403 Rooftop Unit 2 Base Unit Packaged Rooftop Builder 1.46 Page 4 of 43 Certified Drawing for 2ton Project: -Untitled1 05/10/2017 Prepared By: 06:28AM Ult (LE(TAICIL 41021 II ulT EE 3(41(9/00 CENTER OF 0400121 19:060 CAA9ACTFPISTICI l9 AG "A" 0 2 2 49912-21(2470157601330 201/230-1-60 104 139.0 13-3/4 1111 22-13716 519.4 15-5716 300.9 15-11/16 391.5 .7',"'..--2!-7/1f-+ 1191/-,6/(302040/(,C/3( 2007130-1-60 136 752.0 45-3/1 1162 12-13/16 5794 +5.3/21 300.9 15-13/16 401 6 /252 11•"- u9l(-21[3{10607090II S/51f/)208,211-1-60. 206223E-3-60. 160-3-65 349 758.0 51-3/1 1313 17-13/11 379.1 +5'S/1i 300.9 16-578 122.3 .131.17 1147 71 t25r 11 3-7/26 CO01E1 093401 19700 107 3] .rlb 11.2A51 'I' 2' 73' •1' 2 11 201:230 13.0 Mr 11/ 2(4 91.2 0I.1 706.1 46.1 019.91-3/1 1 gut NUM i Su 94 36 1:2011231 52.1 23/ 11 22.1 71 10.37.7'00.1 04 1"-1 717.1 13 3 531 1 0 i •110011 4.77 1 409uA6 I 567102+1 i 15-15711 / OPEN160 1 111 ; [111.1] 010 2(4[04 1 mom C.E VICSI 111 M�IRI.1 AM I EFF---3-1n1 0/210004 COIL- ±-, ••1 001.07 IC'W AUr 14(2(3 IYMI DICT 1101 OF/2411 -' ./4 1155.61 I 2 154.81 F 'F ( 511E OPPOSITE 03[15. _11 1355.41 •r• 00TTOM OF u6IT. ..Ill I+1.11 -bliffiVggilt 1.4• I 6 FLA PANEL .. .36 1171.41 ... _ 052.1 NBC MOO CLIWbVIOIL -+ KI I165(.III * 1[1/(00 341 r5.Pm!F4191 SIDE... 12 0066.61 6 4417 AND/6(00660(0 5/6FACE5.200(6(9702 SID... 36 1974.01 (60004 COI! ,T� V •610004 COIL 117111 000 02914(63,•PPE.9019 11101)011E4 42 11010 11 EW WOW Cltl1YQ F1 0 4110 YO RIM= t94P.COIL ACCESS SIDE I10 4 01 1YMI Poo((01,7 SLOE 12(1160.01 /10(EPT FOR NEC IEOUI4EME4TS1 0912 TOP 10 Er2+9.21 SIO(OPPOSITE MI5 Dxr RI(l 12 1104,01. 06161400 0[5T44(ES IF/612 IS PLACE)LE55 TNA4 12[30191 FRCN 0411 17-124 -- SYSIE4.20EN 5157E0 2(0106408((1619E(06+406(3(0. 1799.51 16651)_ 01763 61 +►4-1/2 I -. I. _.. __. (771.31 1111E6510,5 IN El ANE IN r 11110101 •iouioiomioi / CCtS51V16E1 iuiiiiuui6 I1III0IU1U 9161 DIP. A III1HOHifiI •1• •I!HUJOIIHIIIH r4-12 Ira'!22.110 D 4A CIpLE ; ` r: 1 f (123.9] O1 E TA _l[ c 1 © I15 1110 L DxTll 011/2461103.21 2(01100ELC711711 [ 1111111i •2� 7!5065411/IS-Ste � �] 1DIENING 14-5/16 1394.91 III,' • •°(-, ,�Dil f363 fl [259197 yjIMS 7-3x9 ( ,�� �- I 1 I• •o• __�� �;''�',VL'�� ria I ff u ao .�1- •0' °'1 12-1914 (GNPA P '00(1 1-13/I1S/f It325. POOEL •P Putt 1'71.21 i U el M1• (12 I1 6.9 T 32-Le 7-'Ili WS E02 07 3-7716-... 926.7 49-3/16097 31 0(414 0111(1 (2204 30 052 41 -+. 2001-779II 31-329-� 9-776 •-- IT/g222327 7/1'9 11 0 1 T LEFT SIX VEW �R V� 1-13716 i f1 i R n� ` 1rs 0.91 154f.n 1159.91 r 4'(9 2 77 Of[P Gr .iK •600 FRONT SIDE •SG11 REAR VEW 48VL500404 _ Packaged Rooftop Builder 1.46 Page 5 of 43 Performance Summary For 2ton Project: -Untitled1 05/10/2017 Prepared By: 06:28AM Part Number:48VL-C240403 ARI SEER. 14.00 Base Unit Dimensions Unit Length. 48.2 in Unit Width- 32.6 in Unit Height 43.8 in Total Operating Weight 304 lb Unit Unit Voltage-Phase-Hertz. 230-1-60 Air Discharge. Vertical Fan Drive Type. Direct Actual Airflow. 787 CFM Site Altitude. 0 ft Cooling Performance Condenser Entering Air DB. 95.0 F Evaporator Entering Air DB. 80.0 F Evaporator Entering Air WB. 67.0 F Entering Air Enthalpy- 31.44 BTU/lb Evaporator Leaving Air DB- 59.9 F Evaporator Leaving Air WB- 57.9 F Evaporator Leaving Air Enthalpy- 24.96 BTU/lb Net Cooling Capacity 22.94 MBH Net Sensible Capacity 17.05 MBH Total Unit Power Input 2.00 kW Coil Bypass Factor 0.029 Mixed Air Outdoor Air Airflow 420 CFM Outdoor Air DB. 95.0 F Outdoor Air WB. 77.0 F Outdoor Air Htg. Temp 35.0 F Return Air DB. 76.0 F Return Air WB. 64.0 F Return Air Htg.Temp 70.0 F Heating Performance Heating Airflow. 787 CFM Entering Air Temp. 70.0 F Leaving Air Temp. 108.8 F Gas Heating Input Capacity 40.0 MBH Gas Heating Output Capacity 33.0 MBH Temperature Rise. 38.8 F AFUE(%). 81.0 Supply Fan External Static Pressure- 0.40 in wg Options/Accessories Static Pressure Wet Coil- 0.04 in wg Total Application Static(ESP+ Unit Opts/Acc.)- 0.44 in wg Fan RPM. 1050 Fan Power 0.25 BHP Fan Motor Size, hp. 1/2 NOTE- Medium Motor Speed,Vert Electrical Data Minimum Voltage- 197 Packaged Rooftop Builder 1.46 Page 6 of 43 Performance Summary For 2ton Project: -Untitled1 Prepared By: 05/10/2017 06:28AM Maximum Voltage' 253 Compressor RLA. 8.7 Compressor LRA. 46 Outdoor Fan FLA(ea). 0.6 Indoor Fan Motor FLA' 3.8 Power Supply MCA. 15.2 Power Supply MOCP(Fuse or HACR) 20 Control Panel SCCR:5kA RMS at Rated Symmetrical Voltage Acoustics Sound Rating. 73.0 db Sound Power Levels, db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz NA NA NA 125 Hz NA NA 54.3 250 Hz NA NA 61.3 500 Hz NA NA 55.2 1000 Hz NA NA 54.8 2000 Hz NA NA 57.1 4000 Hz NA NA 53.6 8000 Hz NA NA 43.1 Advanced Acoustics IN 0 0 . ....... .. ....... ......... . ....... ,, Lt 0 �0 Si S Advanced Accoustics Parameters 1. Unit height above ground' 30.0 ft 2. Horizontal distance from unit to receiver 50.0 ft 3. Receiver height above ground- 5.7 ft 4. Height of obstruction. 0.0 ft 5. Horizontal distance from obstruction to receiver: .0.0 ft 6. Horizontal distance from unit to obstruction. 0.0 ft Detailed Acoustics Information Octave Band Center Freq.Hz 63 125 250 500 1k 2k 4k 8k Overall A 0.0 54.3 61.3 55.2 54.8 57.1 53.6 43.1 64.8 Lw B - 38.2 52.7 52.0 54.8 58.3 54.6 42.0 62.1 LwA 26.2 C 0.0 21.9 28.9 22.8 22.4 24.7 21.2 10.7 32.4 Lp 5.8 20.3 19.6 22.4 25.9 22.2 9.6 29.7 LpA 26.2 Packaged Rooftop Builder 1.46 Page 7 of 43 Performance Summary For 2ton Project: —Untitled1 0517 Prepared By: 06:28/10/20 M Legend A Sound Power Levels at Units Acoustic Center, Lw B A-Weighted Sound Power Levels at Unit's Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp D A-Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI /10/20 Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. Packaged Rooftop Builder 1.46 Page 8 of 43 Unit Feature Sheet for 2ton Project: -Untitled1 05/10/2017 Prepared By: 06:28AM There is no Certified Drawing available for this tag Packaged Rooftop Builder 1.46 Page 9 of 43 Spec Sheet for 2ton Project: -Untitledl 05/10/2017 Prepared By: 06:28AM Packaged Rooftop Builder 1.46 Page 10 of 43 3 ton Project: -Untitled1 Prepared By: 05/10/2017 06:28AM 3 ton Tag Cover Sheet Unit Report Certified Drawing Performance Report Unit Feature Sheet Spec Sheet Packaged Rooftop Builder 1.46 Page 11 of 43 Unit Report For 3 ton Project: —Untitledl 05/10/2017 Prepared By: 06:28AM Unit Parameters Dimensions(ft. in.)&Weight(lb.)*** Unit Model. 48KCDA04A2A6-0A0A0 Unit Length. 6'2.375" Unit Size. 04(3 Tons) Unit Width. 3' 10.75" Volts-Phase-Hertz' 460-3-60 Unit Height' 2'9.375" Heating Type. Gas Total Operating Weight 500 lb Duct Cfg. Vertical Supply/Vertical Return Low Heat "' Weights and Dimensions are approximate. Weight does not include unit packaging. Approximate dimensions are Single Stage Compressor Models provided primarily for shipping purposes.For exact dimensions and weights,refer to appropriate product data catalog. Lines and Filters Return Air Filter Type. Throwaway Return Air Filter Quantity. 2 Return Air Filter Size. 16 x 25 x 2 Unit Configuration Medium Static Option Belt Drive Al/Cu-Al/Cu Base Electromechanical Controls Standard Packaging Warranty Information 1-Year parts(std.) 5-Year compressor parts(std.) 10-Year heat exchanger-Aluminized(std.) No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 48KCDA04A2A6-0A0A0 Rooftop Unit 4 Base Unit Medium Static Option Belt Drive None Packaged Rooftop Builder 1.46 Page 12 of 43 Certified Drawing for 3 ton Project: -Untitled1 Prepared By: 05/10/2017 06:28AM NOTES: T. DIMENSIONS AAE IN INCHES, DIMENSIONS UNITED P.O.ear HADD THIS OOCDNCXT a TXE PROPERTY of CARRIER CORPORATION IN [ ]ARE IN MILLIMETERS. UNIT J K f 1 PHASE) N(3 PHASE) TECHNOLOGIES sr AAw9E,Nr I� TEXTf MI IL RNOiDB F�DI3C101[DO ARRIER CORPORAARRIER SMNISSIOM Of TXE9E DAAXINOS OA DOCWWtl i3 2. CENTER OF GRAVITY 48KC 04 33 3l8 '143777118 id 1/8 CAO R]EA 13221 OORpOAAT10X'S XRI7TEN CONSENT. ODES MOIACCEPTAXCE EOFACOXTdACOTE (8471 [3771 [377] 3. DIRECTION OF AIR FLOW 48KC OS 841/]8 1143117118 13 7/18 1[41218 CONNECTION SIZES 48KC 06 41 3/8 1E44777/18 18 5/8 A I 3/8" [351 DIA FIELD POWER SUPPLY HOLE 1051] [/72] 8 2' [501 DIA POWER SUPPLY KNOCKOUT C 1 3/4' 151]DIA GAUGE ACCESS PLUG 33-3/8 I D 7/8" 1221 DIA FIELD CONTROL WIRING HOLE 18481 E 3/4"-14 NPT CONDENSATE DRAIN F 1/2"-14 NPT GAS CONNECTION 32-1/4 ECONOMIZER HOOD G 2 1/2 ' 1641 DIA POWER SUPPLY KNOCK-OUT (8181 • (OPTIONAL) • 16 FILTER ACCESS$)PANEL [4061 (TOOL-LES • co tl CONDENSER •ACCESS • COIL THESETHRU-THE-BASE CHART HOLES REQUIRED 3OR VSE PANEL t CRBTMPWAOOtA01, 003001 INDOOR COIL I ! tl ACCESS PANEL �. THREADED WIRE REO'D HOLE COND1/2 SIZE USE SIZES IMAX1 � ��; %EST 10-7/8 W 1/2" ACC. 7/8" [22.21 \o X 24V 7/8" [22,2] ' �B���__ , £l 41 �( l / RETURN AI0. • (2771 RETURN Y • 3/4" 1001,003) POWER 1 118" [28.41 [1111] T1' .:il - „ T AIR 2•X (003) 1/2'FPT GAS 1 3/16' 130.01 BACK ANDLE 2.5/8- � • FOR"THRU THE-BASEPAN' FACTORY OPTION, 677 TYP • ...._.. ..-f' } f1TTINGS FOR ONLY X,Y, 8 Z ARE PROVIDED CURB i F ALT, 1 I SELECT EITHER 3/4°OR I/O" WIDTH �X DRACONDENSATE DENSATE 173/4 R I " FOR POWER, DEPENDING ON WIRE SIZE 18-1/8 1 IN BASEPAN SUPPLY(4511 26-1/2 29-3/8 �• 10011 PROVIDES 3/4'FPT THRU CURS (459] rI AIR (6731 17471 SUPPPLY FLANGE S FITTING. 16-1/8 14-1/4 12-1/4 I 14111 13631 (3121 SEE THRU THE [ i I I ,, BASE CHART _ I'[ [1574 1 1 +, 12-1/8 -- -3/8 25 LUE (3071 (851 16361 4 HOOD K [1001 TOP [470 72 4-5/8 [1181 126512 III mELECTRICAL [26511-1/4 ' DISCONNECT 1 T'-'����' .. (321 f LOCATION •LONDENSER =-- • J ACCESS PANEL ROL SOX ' ACCESS BLOWERCONDEE STD NSATE DRAIN I __COIL -J`I • r�� III LITER OPTIONAL — FACTORY _ 25-1/8 INSTALLED , �- 19-9/2 OPTIONAL r I (6381 I —•-- �, 18-3/4 RETURN 1 OUTSIDE CONVENIENCE — 14941 FACTORY (4271 AIR OUTLET --,--_-..----=-- INSTALLED __ F HANDLE 129818 SUPPLY AIR AIR I DISCONNECT _ • II 6.5/8 l� N —I _ I Til 3 n1 21-1/4 EiFir - ��ri (168) 10 0 x _• r+-� - =J,0 -� ./[5397 3937 HANDLE (155] `�7 46-3/4 -12131 II [11871[11871 30-1/8 [213] 6-5/8 7 6 [1641 [169] [177] (1521 74-3/8 26-7/8 [18881 [6621 BAROMETRIC LEFT SUP4 31-1/4 RELIEF 931 FLOW FRONT PLY AIA RETURN RIGHT • AIR SHFET DATE I MERCEDES I 48KC 04-06 SINGLE ZONE ELECTRICAL I REV IDF2 09-16-14 - COOLING WITH GAS HEAT 486C000281 Packaged Rooftop Builder 1.46 Page 13 of 43 Certified Drawing for 3 ton Project: -Untitled1 Prepared By: 05/10/2017 06:28AM UNITED P.O.BOX 1000 THIS DOCIWEN1 IS iO4 PROPERIT Of CARRIER CORPORATIOx SUBMISSION or TORSI ORA.IWS OR DOCUMENTS STD UNIT CORNER CORNEA CORNER CORNEA TECHNOLOGIES 5r0604SE,XV 410 10 DF[IYCIEO UPON(Mf ERPRFSS COXOI110N 4 ix[ GOES ROl CONSTI INIE PAPi PfRFORY4Xtf OR UNIT WEIGHT WEIGHT IRI WEIGHT y81 WEIGHT ICI WEIGHT ID) C.G. HEIGHT CARRIER SSW Cg1i[Ni3 WILL NOR B[DISCLOSER OR USED/GROUT CARRIER ACCEPI4XC[OR COMR4C1. CWPORAr10X'S.111101 CONSENT. LBS. KG. LBS. NG. LBS. KG. LBS. KG. LBS. KG. X y 2 48KC 04 490 222 120 54 111 50 125 56 135 61 35 3/4 [908] 24 3/4[628] 18 7/8 0479] 48HC 05 544 246 130 58 126 57 142 64 146 66 36 3/4 [9331 24 3/4(6281 18 7/8 0479] 4880 06 597 270 141 64 156 70 158 71 142 64 39 1/8[9931 23 1/2[597] 20 1/8[5111 .STANDARD UNIT IS W GAS HEAT AND WITHOUT FOR OTHER OPTIONS AND WEIGHT CCESSOIRTIES L�REFER TO THE PRODUCT DATAKAGING.CATALOG, CORNER A CORNER B • I1t\11�® � • 1 CORNER D CORNER C TOP „, ��-- k>H dr. „00 �. )`: : 00g FRONT 0x011 D41E 106000EDES 486C 04-06 SINGLE ZONE ELECTRICAL ROT 2OF2 09-16-14 - COOLING WITH GAS HEAT 48HC 000281 Packaged Rooftop Builder 1.46 Page 14 of 43 Certified Drawing for 3 ton Project: ~Untitled1 Prepared By: 05/10/2017 06:28AM Service Clearance • LOCATION DIMENSION CONDITION C08337 48-in(1219 mm) •Unit disconnect is mounted on panel A 18-in(457 mm) •No disconnect,convenience outlet option •Recommended service clearance 12-in(305 mm) •Minimum clearance 42-in(1067 mm) •Surface behind servicer is grounded(e.g.,metal,masonry wall) 8 36-in(914 mm) •Surface behind servicer is electrically non-conductive(e.g., Special •Check for sources of flue products within 10.ft.of unit fresh aintake hood) C 36-in(914 mm) •Side condensate drain is used 18-in(457 mm) •Minimum clearance 48-in(1219 mm) •No flue discharge accessory installed,surface is combustible material 42-in(1067 mm) •Surface behind servicer is grounded(e.g.,metal,masonry wall,another unit) D 36-in(914 mm) •Surface behind servicer is electrically non-conductive(e.g.,wood,fiberglass) Special •Check for adjacent units or building fresh air intakes within 10-ft.of this unit's flue outlet NOTE:Unit not designed to have overhead obstruction.Contact Application Engineering for guidance on any application planning overhead obstruction or vertical clearances. Cuua 1.z Packaged Rooftop Builder 1.46 Page 15 of 43 Performance Summary For 3 ton Project: -Untitled1 05/10/2017 Prepared By: 06:28AM Part Number:48KCDA04A2A6-0A0A0 ARI SEER. 14.00 Base Unit Dimensions Unit Length- 74.4 in Unit Width- 46.8 in Unit Height- 33.4 in Operating Weight Base Unit Weight. 490 lb Medium Static Option Belt Drive- 10 lb Total Operating Weight 500 lb Unit Unit Voltage-Phase-Hertz- 460-3-60 Air Discharge- Vertical Fan Drive Type- Belt Actual Airflow- 1200 CFM Site Altitude- 0 ft Cooling Performance Condenser Entering Air DB- 95.0 F Evaporator Entering Air DB- 80.0 F Evaporator Entering Air WB- 67.0 F Entering Air Enthalpy- 31.44 BTU/lb Evaporator Leaving Air DB- 59.4 F Evaporator Leaving Air WB- 57.5 F Evaporator Leaving Air Enthalpy- 24.70 BTU/lb Gross Cooling Capacity- 36.41 MBH Gross Sensible Capacity- 26.71 MBH Compressor Power Input 2.95 kW Coil Bypass Factor 0.113 Mixed Air Outdoor Air Airflow- 420 CFM Outdoor Air DB- 95.0 F Outdoor Air WB- 77.0 F Outdoor Air Htg.Temp• 35.0 F Return Air DB- 76.0 F Return Air WB- 64.0 F Return Air Htg.Temp• 70.0 F Heating Performance Heating Airflow 1200 CFM Entering Air Temp 70.0 F Leaving Air Temp- 115.5 F Gas Heating Input Capacity- 72.0 MBH Gas Heating Output Capacity- 0.0/59.0 MBH Temperature Rise- 45.5 F Thermal Efficiency(%). 82.0 Supply Fan External Static Pressure- 0.40 in wg Fan RPM- 778 Fan Power 0.37 BHP NOTE- Selected IFM RPM Range: 770-1175 Electrical Data Voltage Range- 414-506 Packaged Rooftop Builder 1.46 Page 16 of 43 Performance Summary For 3 ton Project: -Untitledl 05/10/2017 Prepared By: 06:28AM Compressor#1 RLA. 5.8 Compressor#1 LRA. 38 Outdoor Fan Motor Qty. 1 Outdoor Fan FLA(ea). 0.5 Indoor Fan Motor Type. MED Indoor Fan Motor FLA. 2.5 Combustion Fan Motor FLA(ea). 0.25 Power Supply MCA. 11 Power Supply MOCP(Fuse or HACR). 15 Disconnect Size FLA. 10 Disconnect Size LRA- 57 Electrical Convenience Outlet None Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage Acoustics Sound Power Levels, db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz 82.5 85.0 78.2 125 Hz 75.0 72.2 78.0 250 Hz 64.5 57.9 74.2 500 Hz 61.3 57.9 73.3 1000 Hz 58.1 57.8 70.6 2000 Hz 52.4 51.9 66.0 4000 Hz 53.3 46.7 62.4 8000 Hz 47.3 38.0 56.9 A-Weighted 65.3 63.8 76.0 Advanced Acoustics Si _ _ 0 0 , t. {.. ;© Advanced Accoustics Parameters 1. Unit height above ground. 30.0 ft 2. Horizontal distance from unit to receiver 50.0 ft 3. Receiver height above ground. 5.7 ft 4. Height of obstruction. 0.0 ft 5. Horizontal distance from obstruction to receiver 0.0 ft 6. Horizontal distance from unit to obstruction. 0.0 ft Detailed Acoustics Information Octave Band Center Freq. Hz 63 125 250 500 1k 2k 4k 8k Overall A 78.2 78.0 74.2 73.3 70.6 66.0 62.4 56.9 82.9 Lw B 52.0 61.9 65.6 70.1 70.6 67.2 63.4 55.8 75.4 LwA Packaged Rooftop Builder 1.46 Page 17 of 43 Performance Summary For,3 ton Project: —Unt.itled1 Prepared By: 05/10/2017 06:28AM C 45.8 D 119.6 29.5 33.2 37.7 38.2 34.8 31.0 23.4 450.5 Lp 3.0 LpA 1 Legend A Sound Power Levels at Unit's Acoustic Center, Lw B A-Weighted Sound Power Levels at Unit's Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp D A-Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. Fan Curve 20 11COTM \N .‘13:0334 \ 1.81 L 1.6C X12 u)1.0I _ a_ 0.6 --- N.... .77 OA � \ .. \� 1f. tP 02 - N A \ 1�HP\ 0.0 I I 1 1 I mo -, 1 I I 1 I I I i, 0.0 03 0.6 09 12 1.5 1.8 2.1 Airflaw(CFM-thousands) 2a RPM=778 BHP=0.37 MaximumRPM=2100 MaximumBHP=2.90 Note:Please contactapplication engineering forselections outsidethe shadedregion. SC-System Curve RP-Rated Point Packaged Rooftop Builder 1.46 Page 18 of 43 Unit Feature Sheet for 3 ton Project: -Untitled! 05/10/2017 Prepared By: 06:28AM Carrie Q WeatherMaker' — 48KC PACKAGED ROOFTOP GAS HEATINGIELECTRIC COOLING UNITS-14 SEER 3,4,5 TONS STANDARD FEATURES INCLUDE: .11_ ••MePuerotsn a(Rnd e10xceA)edHFsCAreSHRAfrigeEra9nt0 .1energyeffipenrykvels _ • Scrod compressors with internal Ina break and overload pr otection`i •r • Single-stagecooing capacity control • SEERS upto14.0.EER'suptol2.0 `� •Acutmi"refrigerant meterng system +Na ' • Exclusive non-ormsive composite condensate pan in accordance with k. _ ASHRAE Standard 62.sloping design,sad*°reenter dram • Standard cooing operation up to 115°F(46'C)and down to40.F(4'C) +^. ` ,. - down to 25'F(-4'C)with welter start kit. • Pie-panted exterior panels and primer-coated ntenorpanels tested to 500 hours sat spray protection • FuRy insulated cabinet • Exclusive IGC sold-state control for on-board diagnostics with LED ��� • error code designation bumer control logic and energy saving indoor 'ASIIfan motor delay „,',-,-,-}c/-,,, s • Low NOx models that meet California Ar Quaky Management 1,74," t Z P�uron. • Induced draft gas heat combushon design COMPtiaj • Redundant gas valves with up to two stages of heating • Low pressure and high pressure switch protected. MAINTENANCE FEATURES: •Access panels with easygrip handles • Innovative easy starting,no-step screws on unt access panels •Two-inch p disposable return arbiters and Tool-less fitter access door WEATHERMAKER SERIES • ECM indoor motor is standard with optional bet drive systems WeatherMaker 48KC (14-SEER) units are one-piece gas • heating,electric cooling units that are pre-wired and charged simplified boardol box tngsimple safety aloud troubleshooting and smpihed control box arrangement with Puron(R-410)refrigerant. They are factory tested in both • Exclusive IGC sold-state control for on-board deg noshesweh LED heating and cooling modes,and rated in accordance with AHRI enoroode designation,bumercontrol logic and energy saving edoor Standards 210/240. WeatherMaker units are designed in fan motor delay. accordance with UL Standard 1995. and listed by the Underwriters'Laboratories. INSTALLATION FEATURES: • Thru-the-bottom power entry cepabiky • Single pont gas and electric connections Approved and certified by: • Ful permeter base rat with buit-in rigging adapters and fork slots • Field convertible fmmvertcal to honzontai airflow C..`g CERTIFIED- STANDARD WARRANTY: • 10-year heat exchanger—l5-yearstan less steel option u..d r.....Ir Gin.,,, • 5-year compressor C US uw. r ° • 1-year parts v.,,.�,,,..,.,,,,, • Many optional upgrades also eversible rsr�ry w�._n� d.k5 per , . OPTIONS INCLUDE BUT ARE NOT LIMITED TO: • Prensert ink and RTU Open Muth Protocol DOC Controls • Supply and Return Air Smoke Detectors,high static motors • Louvered condensercorguards • Disconnect switch and convenience outlet options • Stainless Steel heat exchanger option • Corrosion resistant coil Coating, Certified to ISO 9001 • High static motor options • Patented Hurndi-Wee adaptive dehumidification system.This option also includes Motonnester I controls • Hinged access panels • Integrated economizer system.Standard and tJCra Low Leak versions Fora complete list of options and accessories referto the Product Data Catalog for this unit. Packaged Rooftop Builder 1.46 Page 19 of 43 Project: -Untitledl Spec Sheet for 3 ton 05/10/2017 Prepared By: 06:28AM Packaged Rooftop Builder 1.46 Page 20 of 43 5 ton Project: -Untitled1 Prepared By: 05/10/20 06:28AM 5 ton Tag Cover Sheet Unit Report Certified Drawing Performance Report Unit Feature Sheet Spec Sheet Packaged Rooftop Builder 1.46 Page 21 of 43 Unit Report For 5 ton Project. -Untitled1 Prepared By: 05/10/2017 06:28AM Unit Parameters Dimensions(ft.in.)&Weight(1b.)*** Unit Model- 48KCDA06A2A6-0A0A0 Unit Length. 6'2.375" Unit Size. 06(5 Tons) Unit Width- 3' 10.75" Volts-Phase-Hertz. 460-3-60 Unit Height 3'5.375" Heating Type. Gas TM• Total Operating Weight 607 lb Duct Cfg. Vertical Supply/Vertical Return Low Heat *" Weights and Dimensions are approximate. Weight does not include unit packaging. Approximate dimensions are Single Stage Compressor Models provided primarily for shipping purposes.For exact dimensions and weights,refer to appropriate product data catalog. Lines and Filters Return Air Filter Type. Throwaway Return Air Filter Quantity. 4 Return Air Filter Size' 16 x 16 x 2 Unit Configuration Medium Static Option Belt Drive Al/Cu-Al/Cu Base Electromechanical Controls Standard Packaging Warranty Information 1-Year parts(std.) 5-Year compressor parts(std.) 10-Year heat exchanger-Aluminized(std.) No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 48KCDA06A2A6-0A0A0 Rooftop Unit 3 Base Unit Medium Static Option Belt Drive None Packaged Rooftop Builder 1.46 Page 22 of 43 Certified Drawing for 5 ton Project: -Untitled( Prepared By: 05/10/2017 06:28AM NOTES: 1. DIMENSIONS ARE IN INCHES, DIMENSIONS UNITED P.o.XOR ARDd iNn XBOO eT[s THE PROPEAir or CAARI EP CORPORATION IN[ ]AAE IN MILLIME7ER5. UNIT J N 11 PHASE) K (3 PHASE) TECHNOLOGIES SYRACUSL Xr Axo is KUYEAEO NPON rxE EXPRESS coxal TNA(TRE SO6MFSSIOX of TxeSF OAARINOS oA DOCONEpis CARRIER 13RR1 CONTENTS ME LL NOi XE OISCE03 E0 OR OSEO W[iXWT CARR IFA GOES XOT COpSTIixiE PART P[RPORNANCf OR 33 3/8 14 7/8 14 7/8 CORPORATION'S WAI ITEX CONSENT. ACCEPTANCE 6 C(WTRAGi. 2.� CENTER OF GRAVITY 48NC 04 !8411 [3711 1317] 48NC 05 3E38431/18 1143171/18 118052/18 CONNECTION SIZES 3. DIRECTION OF AIR FLOW [4721 41 3/8 14 718 18 5/8 A 1 3/8' 1351 DIA FIELD POWER SUPPLY HOLE d8NC 0fi [1051] [371) [4721 B 2' [50] DIA POWER SUPPLY KNOCKOUT C 1 3/4' [511 DIA GAUGE ACCESS PLUG 33-3/8 0 7/8" [221 DIA FIELD CONTROL WIRING HOLE [8481 E 3/4"-I4 NPT CONDENSATE DRAIN F 1/2"-14 NPT GAS CONNECTION 82.1/4 A • —T 0 2 1/2" [641 DIA POWER SUPPLY KNOCK-OUT [8181 ECONOMIZER HOOD (OPTIONAL) 16 FILTER ACCEj [1061 !TOOL-LCOMP. ACCESS CONDENSER THRU-THE-BASE CHART PANEL ( COIL I • ,• .. , Al iHECRBTMPWR001A01, 003801SE HOLES REQUIRED FOR UGE INDOOR CO6 ACCESS PAI THREADED WIRE REO'D HOLE � CONDUIT SIZE USE SIZES IMAM.) 25-5/8 1/2 EAu � 1� ^- —� ♦ 1/2" ACC. 718" [22.21 _ --I1. r \ [652] [27718 % 2dV 718" [22.2] �[lIf1•�I �����Iil'El 44 * •Illy,' 1// _ RETURN RETURN AIA Y 3003 (1/1 0031 POWER 1 116 [30,5 [11171 �\‘,2 -4-,:„. (4��� � „- 9�T AIR In• 1003) 1/2' FPT GAS 1 3/18" [30.0] BACK ANDLE 2-s/$_ � (671 ,�_�� FOR"THRU THE BASEPAN' FACTORY OPTION, TYP U } FITTINGS FOR ONLY N,Y, $Z ARE PROVIDED E ALT. CURB ! CONDENSATE SELECT EITHER 3/4'OR 1/2" WIDTH DRAIN OPENING 11-314 " * FOR POWER, DEPENDING ON WIRE SIZE 18-1/8 1 ,Z [N BASEPAN SUPPLY 26-1/2 28-3/8 AX (001)PROVIDES 3/4' FPi THRU CURB [4591 I AIR [6731 17471 SUPPLY FLANGE S FITTING. 16-I/8 14-1/4 12-1/4 AIR [4111 [3631 [3121 SEE THRU THE 6- Id 4 { I BASE CHART 4 [157 --- )2-1/8 `3-3/8 25 [3071 1 851 K LUE It [636] -4 HOOD[1001 TOP [47012 4-5/8 [1181 126112 [2851 1-1/4 ELECTRICAL -- [32] j DISCONNECT r —-_-_H �II DISCONNECT CONDENSER COIL — CONTROL BON INDOOR BLOWER ACCESS PANEL ACCESS • E STD. ILTEA I '--1--- -=' _ CONDEDRAIN I. • I J a i DRAIN OPTIONAL — PTIONAY _ 251!8 ,_.4.......... / OUTS1DE INSTALLED , �- 19-1/2 OPTIONAL 16-3/4 I 1638] II CONVENIENCE — 14941 FACTORY I42TA RETURN AI X F 11-3/8 I AIR OUTLET �� INSTALLED — HANDLE [269] SUPPLY ASR 1 _ DISCONNECT B�� o�ii [1688 100 emit.iiia—— �.� �` 6-1/8 � • 539]4 3-3/4 1c)(*)F` [155] 6 [951 46.3/4 HANDLE 8-3/8 111871 30-1/8 [213] 6-5/6 7 6 [7647 [1691 11771 [152] 74-3/8 26-7/8 [1888] [6821 BAROMETRIC LEFT S [793]4 RELIEF FLOW FRONT AIRUPPLY 4 f RETURN RIGHT AIR SHEET I DATEMERCEDESI COOLING WITH GAS HEAT 48KC 04-06 SINGLE ZONE ELECTRICAL 48KC000261 REV 1 OF 2 09-16-14 I - Packaged Rooftop Builder 1.46 Page 23 of 43 Certified Drawing for 5 ton Project: -Untitledl Prepared By: 05/10/2017 06:28AM C UNITED P.O.NOR AD08 IRIS DOLIMCXI IS 100 PROPER,,OE CARRIER CORPORAT10P SuButSS10A or THESE ORAWINBS OR DOCuufN% STD. UNIT CORNER CORNER CORNER CORNER TECHNOLOGIES 51050 USE.RE 0or�iTIS S WILL 501IH010EDr°ei"DiufOSED OREXPRESS USEDOSRS WITHISDN 1801 CARRIER DOLS 801 LONSTI LDtC PARI PIPFOPNANCF OR UNIT WEIGHT WEIGHT(AI WEIGHT(81 WEIGHT ICI WEIGHT ID) C.G. HEIGHT CARRIER RSxz1 CORPORATION'S WR(il[N CONSENT. ACCEPIAN[f OF CONTRAIL. LBS. NG. LOS. NG. LBS. NG. LBS. NG, LBS. NG. N r 2 4811C 04 490 222 120 54 111 50 125 56 135 61 35 3/4 1908] 24 3/4[6281 18 7/8[4791 48NC 05 544 246 130 58 126 57 142 64 146 66 36 371 [933] 24 3/4[6281 18 7/8[4791 48NC 06 597 270 141 64 156 70 158 71 142 64 39 1/8[993] 23 1/2[597] 20 1/8[5111 FOR OTHER UNIT OPTIONS AND ACCESSORIESGHT IS WITH ,REFER HEATW GAS N WITHOUT THE PRODUCT DATA CATALOG. CORNER A CORNER B x 0 ter= • ��`�� fllll/ //�,„111111'i . B CORNER D ` • �._ i CORNER C X TOP • Y - 2 00 i' •j 1 '. : 00 FRONT SHE[1 RAIU SPERM LS 486C 04-06 SINGLE ZONE ELECTRICAL REV 2 OF 2 09-16-14 - COOLING WITH GAS HEAT 4811C000281 _ Packaged Rooftop Builder 1.46 Page 24 of 43 Project: —Untitled1 Certified Drawing for 5 ton Prepared By: 05/10/2017 O6:28AM Service Clearance LOCATION DIMENSION CONDITION c08337 48-in(1219 mm) •Unit disconnect is mounted on panel •No disconnect,convenience outlet option A 18-in(457 mm) •Recommended service clearance 12-in(305 mm) •Minimum clearance 42-in(1067 mm) •Surface behind servicer is grounded(e.g.,metal,masonry wall) 8 36-in(914 mm) •Surface behind servicer is electrically non-conductive(e.g.,wood,fiberglass) Special •Check for sources of flue products within 10-ft.of unit fresh air intake hood C 36-in(914 mm) •Side condensate drain is used 18-in(457 mm) •Minimum clearance 48-in(1219 mm) •No flue discharge accessory installed,surface is combustible material 42-in(1067 mm) •Surface behind servicer is grounded(e.g.,metal,masonry wall,another unit) D 36-In(914 mm) •Surface behind servicer Is electrically non-conductive(e.g.,wood,fiberglass) Special •Check for adjacent units or building fresh air intakes within 10-ft.of this unit's flue outlet NOTE:Unit not designed to have overhead obstruction.Contact Application Engineering for guidance on any application planning overhead obstruction or vertical clearances. • Packaged Rooftop Builder 1.46 Page 25 of 43 Performance Summary For 5 ton Project: -Untitled1 05/10/2017 Prepared By: 06:28AM Part Num ber:48KCDA06A2A6-0A0A0 ARI SEER. 14.10 Base Unit Dimensions Unit Length. 74.4 in 46.8 in Unit Width. in Unit Height. 41.4 Operating Weight 597 lb Base Unit Weight. 10 lb Medium Static Option Belt Drive. Total Operating Weight. 607 lb Unit 460-3-60 Unit Voltage-Phase-Hertz. Vertical Air DischargeBelt . Fan Drive Type2000 CFM . Actual Airflow. 0 ft Site Altitude. Cooling Performance 95.0 F Condenser Entering Air DB. 80.0 F Evaporator Entering Air DB. 67.0 F Evaporator Entering Air WB. 31.44 BTU/lb Entering Air Enthalpy. 58.6 F Evaporator Leaving Air DB. 57.3 F Evaporator Leaving Air WB- 24.57 BTU/Ib Evaporator Leaving Air Enthalpy 61.84 MBH Gross Cooling Capacity- 46.23 MBH Gross Sensible Capacity. 5.19 kW Compressor Power Input. 0.058 Coil Bypass Factor Mixed Air Outdoor Air Airflow 420 CFM 95.0 F Outdoor Air DB. 77.0 F Outdoor Air WB. 35.0 F Outdoor Air Htg. Temp 76.0 F Return Air DB. 64.0 F Return Air WB. 70.0 F Return Air Htg. Temp• Heating Performance 2000 CFM Heating Airflow. 70.0 F Entering Air Temp. 97.3 F Leaving Air Temp- 72.0 MBH Gas Heating Input Capacity. Gas Heating Output Capacity- 0.0/59.0 MBH 27.3 F Temperature Rise. 82.0 Thermal Efficiency(%). Supply Fan External Static Pressure. 0.40 in wg 1151 Fan RPM. Fan Power 1.02 BHP NOTE Selected IFM RPM Range: 1035-1466 Electrical Data 414-506 Voltage Range- Packaged Rooftop Builder 1.46 Page 26 of 43 Performance Summary For 5 ton Project: -Untitled1 05/10/2017 Prepared By: 06:28AM Compressor#1 RLA. 7 Compressor#1 LRA. 52 Outdoor Fan Motor Qty 1 Outdoor Fan FLA(ea). 0.9 Indoor Fan Motor Type. MED Indoor Fan Motor FLA. 4.2 Combustion Fan Motor FLA(ea). 0.25 Power Supply MCA. 14 Power Supply MOCP(Fuse or HACR). 20 Disconnect Size FLA- 14 Disconnect Size LRA. 90 Electrical Convenience Outlet. None Control Panel SCCR:5kA RMS at Rated Symmetrical Voltage Acoustics Sound Power Levels, db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz 86.5 86.6 87.5 125 Hz 81.5 78.2 82.5 250 Hz 74.0 65.1 76.1 500 Hz 69.9 62.8 73.6 1000 Hz 66.6 62.1 71.3 2000 Hz 60.7 56.2 67.1 4000 Hz 62.4 51.9 64.1 8000 Hz 57.8 44.4 60.0 A-Weighted 73.3 68.1 77.0 Advanced Acoustics bo : co ir 7 -7-71-1 !) 01 01 01 ( 401 0 �° 0 Advanced Accoustics Parameters 1. Unit height above ground' 30.0 ft 2. Horizontal distance from unit to receiver 50.0 ft 3. Receiver height above ground. 5.7 ft 4. Height of obstruction' 0.0 ft 5. Horizontal distance from obstruction to receiver 0.0 ft 6. Horizontal distance from unit to obstruction' 0.0 ft Detailed Acoustics Information Octave Band Center Freq.Hz 63 125 250 500 1k 2k 4k 8k Overall A 87.5 82.5 76.1 73.6 71.3 67.1 64.1 60.0 89.2 Lw B 61.3 66.4 67.5 70.4 71.3 68.3 65.1 58.9 76.7 LwA Packaged Rooftop Builder 1.46 Page 27 of 43 Performance Summary For 5 ton Project: -Untitledl Prepared By: 05/10/2017 06:28AM C 55.1 50.1 43.7 41.2 38.9 34.7 31.7 27.6 56.8 Lp D 28.9 34.0 35.1 38.0 38.9 35.9 32.7 26.5 44.3 LpA Legend A Sound Power Levels at Unit's Acoustic Center, Lw B A-Weighted Sound Power Levels at Unit's Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp D A-Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. Fan Curve 20 r 1.8 1 21f7ITFTA �- r 14 \ ' �� \ 961®P '�12 1--� - 1- \ A N I cul � \� to 1.0- - � - \---\ - } (13 4-. - ' , \ 3LCH P Q4 - \ \ 2113-P A1'CaP �\ 11[H P 02 , c . iL - - . 0.0 , _I-4- r---it i �ti �� IN 00 03 0.6 0.9 12 15 1.8 21 2.4 2.7 3.0 3.3 Airflaw(CFM-thousands) RPM-1151 BHP=1.02 MaximumRPM=2100 MaximumBHP=2.90 Note:PleasecontactapplicationengMeeringforselectionsoutsidetheshadedregion. SC-System Curve RP-RatedPoint Packaged Rooftop Builder 1.46 Page 28 of 43 Unit Feature Sheet for 5 ton Project: -Untitled1 Prepared By: 05/10/2017 06:28AM Carri 0 -D., WeatherMaker` — 48KC PACKAGED ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS-14 SEER 3,4,5 TONS STANDARD FEATURES INCLUDE: r,,r„ ;' • Puron(R-410A)HFC refrigerant ' •Meets and exceeds ASHRAE 90.1 energy effic envy levels • Sao!compressors with internal Ore break and overload protection • Single-stage cooling apacitycontrol • SEER's up to 14.0.EER's up to 12.0 1 •Acutml'v refrigerant metering system ,.Me 1= r • Exclusive non-conosive composite condensate pane withaccordance •°-.+-"'-*> ASHRAE Standard 62.sloping design,side orcenter drain I • Standard cooing operation up to 115'F(46'C)and down to 40'F(4'C) ,' -__ t» -down to 25'F(-4'C)with winter sten kit. • Pre-panted exterior panels and prinercoated ritenor panels tested to 500 hours salt spray protection • Fully insulated cabinet • Exclusive IGC solid-state control for on-board diagnostics with LED A����� error code designation bumercontrol logic and energy saving indoor fan motor delay r 11 • Low NOx models that meet Cabtomie Air QualityManagement �.. ,t pu�y�„ g CO's'' �,"as ion • Induced draft gas heat combustion design MPL1ANTr • Redundant gas vaeswrth up to two stages of heating • Low pressure and high pressure switch protected. MAINTENANCE FEATURES: •Access panels with easy grip handles • Innovetrve easy starting,no-strip saews on unit access panels WEATHERMAKER SERIES •Two-inch disposable return ad-filters and Tool-less filter access door • Deed Drive—ECM indoor motor is standard with optional belt drive systems WeatherMaker 48KC (14-SEER) units are ono-piece gas • heating,electric cooling units that are pre-wired and charged sflTerminal board fabox ar ngem nafety avant troublashootng and at with Puron(R-410)refrigerant. They are factory tested in both • Exclusive IGC solid-state controlfor on-boarddiagnostcs with LED heating and cooling modes,and rated in accordance with AHRI error code designation.burner control blare and energy saving indoor Standards 210/240. WeatherMaker units are designed in fan motor delay. accordance with UL Standard 1995, and listed by the Underwriters'Laboratories. INSTALLATION FEATURES •Thru-the-bottom powerentry capability • Single point gas and electric connections Approved and certified by: Full perimeter base rad with buitar rigging adapters and fork slots • Field convertible from vertical to horizontal asflow .�.•"�cEunfteo- STANDARD WARRANTY: "'---. • 10-year heat exchanger—l5-yearstainless steel option w.v Po AMR.t«,Ao1 C (Z) US ::: • 5-yearcomp ress or *v u.-..xn. • 1-yearparts • Manyoptional upgrades also available r..a..,Nom. >,W OPTIONS INCLUDE BUT ARE NOT LNAITED TO: "' ,"" • PrerrierLnk and RTU Open Multi Protocol DDC Controls • Supply and Return As Smoke Detectors,high static motors • Louvered condensercodguards • Disconnect switch and convenience outlet options • Stainless Steel heat exchanger option Certified to ISO 9001 • Corrosion resistant cod coating. • High static motor options • Patented ISumach-R1WZer•adaptrve dehumidification system.This option also includes Motomnster I controls • tinged access panels • Integrated economizer system.Standard and Mara Low Leak versions For a complete list of options and aocessones referto the Product Data Catalog forthis unit. Packaged Rooftop Builder 1.46 Page 29 of 43 Project: -Untitled1 Spec Sheet for 5 ton 05/10/2017 Prepared By: 06:28AM Packaged Rooftop Builder 1.46 Page 30 of 43 6 ton Project: -Untitled1 05/10/2017 Prepared By: 0/6:28AM 6 ton Tag Cover Sheet Unit Report Certified Drawing Performance Report Unit Feature Sheet Spec Sheet Packaged Rooftop Builder 1.46 Page 31 of 43 Unit Report For 6 ton Project: -Untitled1 Prepared By: 05/10/2017 06:28AM Unit Parameters Dimensions(ft. in.)&Weight(1b.)*** Unit Moder 48TCDA07A2A6-0A0A0 Unit Length. 6'2.375" Unit Size. 07(6 Tons) Unit Width- 3'8" Volts-Phase-Hertz* 460-3-60 Unit Height 3'5.375" Heating Type- Gas *•* Total Operating Weight 662 lb Duct Cfg. Vertical Supply/Vertical Return Low Heat "* Weights and Dimensions are approximate. Weight does Round Tube Plate Fin Coils not include unit packaging. Approximate dimensions are provided primarily for shipping purposes.For exact dimensions andweights,refer to appropriate product data catalog. Lines and Filters Gas Line Size. 1/2 Condensate Drain Line Size. 3/4 Return Air Filter Type* Throwaway Return Air Filter Quantity* 4 Return Air Filter Size. 16 x 16 x 2 Unit Configuration Medium Static Option(Belt Drive) Al/Cu-Al/Cu Base Electromechanical Controls Standard Packaging Warranty Information 1-Year parts(std.) 5-Year compressor parts(std.) 10-Year heat exchanger-Aluminized(std.) No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 48TCDA07A2A6-0A0A0 Rooftop Unit 1 Base Unit Medium Static Option(Belt Drive) None None Packaged Rooftop Builder 1.46 Page 32 of 43 Certified Drawing for 6 ton Project: -Untitled1 Prepared By: 05/10/2017 06:28AM VOTES Vitriel), PUS>x:an Is rc"wt.n Drwut+Cara.n:.UNIT X7 IS MIMED Arm SNI WV'S CMITIp[AAI TR SN"i6gerOt1R 1[PND 1pPACIrRrTP1. DIMENSIONSAPE IN t8(NES, DINE51o65 /81(••01 33 318 185/8 DRA'HING REPRESENTS PRODUCT BUILT AFTER 0'/D1/201f r+AWWWWXN. :1 0 Int wl+s nsn0l[Cw usaD DIllrour.ArNsn Dou Dm tasnrn•"ArT rxeonuaa IA f 1 ARE IA MI LL INETERS Ie/t1 11111 taralnal MIMI= atnnrtx a tRAnAt7. 2 ® (ESTER OF GP,AYIT" /81(•105 33 318 l4 ue (STARTING OITH SERIAL NUMBER 011 f...' SEE DETAIL "E" 164/1 13777 CORRECTION SIZES 33 33-1/a 3. CIR(CTION OP AIA FLOW 187(••06 113.71+ II748 (848] A 1 3/81 (351 DIA FIELD DOAE8 SUPPLY HOLE /a TCD•Ot 1+ 318 IN? 6 1' [507(16 POWER S PPLY 66006011 4 -[ ALL 4I(5 DRAWN USING 3RD ANGLE 1'0511 37-1t8 • 1 ECOWCWIIER HOOD ' • i C 1 314' (51]DIA GA..6E ACCESS PLUG (aril IOPT1oYAL7 16 D I/6" (771 DIA FIELD CONTROL WIRIAG HOLE 4 _ / [177] E 3/1"-14 NPT CONDENSATE:MIR 13-518 I 16521 i F 1i2"-t4 NPT GAS CORRECTION fTflRE7UPS AIR iG 7 1/7" (6/]OIA POWER SUPPLY RAtxA-OUT — • N���A�� - COAOUITCED W1RE REO'O HOLE y • �\\-� ,��� 51✓� + SIZE USE SII(S INA t.) //-1/d \. ;i--% f I W 112' 1154 11X" 112.1] 11170.91 � _ - E ALT J 79-I1Z x 1+2• 2/V Na^ 112 21 0EV53rE r 311x1 311' POWER 1-'IB' [28.6] OPERING [/St 71 ]' (003A0!1 171"FPT GAS 1-1/81 078 61 1 f BASEPANr SUPPLY FOR'THRU-THE-BASCPAN"FACTORY DATION, 11-I/2 } 26-5/B F(TIIRGS FOR ONLY I. Y. 1 1 ARE P604(5(0 (369] 12-112 1 4I� -•I AIA 1675] SLPPLrt-1/7 AIAA (0G1AO.)PROVIDES311"SPT THAU CURB 1318] 1293) ' SEE 1THADEC TBE FLANGEa F1T7uDIi `. BASE CHARTi 1 6 10-118- -2,73-3/4 12561 (6017 • I— -6-+Is1 ^—3-112 L [ a] _ MI_ A LLE 12-1/8 SEE DETAIL E I__ It Ctl HAD (3017 3 SHEET 5 T 1 6351 2x 75 18-5+8 21 1-5/8 TOP 14721 ['i87 E STD 10-1/2 IECTRIUL COYOENSATE I (2657 o�rm ]ISCONNECT DRAIN I-1/1 LOCATION 1 P .. a - 1321 CONOENSEA `�'�� COIL III A,B.G LCNTRDL 801 _f ^FILTERACCESS PANEL INDOOR aloW(R "-1/8(PTI Nal ,� ACCESS PANEL 16-J// I,6387 STH TORY s 11251 ETUA INSTALLED i S�PPLT AIR AIA CONv FACTORY ' -= OUTLET ,Ii OPTIONAL S- f ® _ INSTALLED ~ 11 1 �l� 19-1/2 FACTORY AADLF 1- + [28918 ,1 1191] DIS'OAYECT E �{ � i 1111 t/1��-�___ 11-11 1 [5397OUTBID( ., 6-518 128! Qi 4411 IIMINI I 11681 O F�1�d = : i11si ��Dr.A��16a— 41 SIDE PROLE _�—•�_ (951 46-5/8 6-5/8 6 (1186] -8-3/8 37-1/8 32111 11691 11711 ['S2] [7667 76- (687182] 4 LEFT a- (186913/a 31-1 / [7917 RELIEF FRONT FLOWEF SLAPLr AIRIii „TERN RIGHT All IITC CLASSIFICATIOrSHEET DATE S.P(RCEDES 4810 04-07 SINGLE ZONE ELECTRICAL I I R(0 U.S. ECCN:NSR I 1 OF 5 18-24-2016 13-05-2015 I COOLING WITH CAS HEAT 48TM500993 H Packaged Rooftop Builder 1.46 Page 33 of 43 Certified Drawing for 6 ton Project: —Untitled! Prepared By: 05/10/2017 06:28AM VOTES. r^ Y�ii 13 YJ(:•[•T(f ill[rpr[rtt p3(WSIU(Orlp+tlG RS•tSSlpi 01 INKS[ NrIW1 M COCf•[+i5 UNIT N `ca r/iSr >If en:14117N iN[Miss(MDISSpI TY+I TN[ pp[s uo(OpSTl C r1•T.[11"X"'a 1. DINFNS ICN$AAC IN INC NES, JINENSION$ 33 3!e ,8 518 (anal 0(S rote[>.0 6(51.c+usro rincut uat[+ IN [ E ARE IA NILIINETERS, 48TC.04 4aAr..4.wpr .a.aAna's asnu:0ASSW A((nu•c[or(anA[T. 18411 14171 2 s CENTER CF GRATIP 48141405 3[36 3i8 1(j77n DRANInG REPRESE4TS PRODUCT BUILT BEFORE 07/01/2017 CONNECTION Sires SEE DETAIL "6" 487[••06 313843/1' 3)1B Y13771/18 1 718 A 1 3/8' (35]DIA FIELD POWER$UPPLI HOLE 3. DIRECTION Of AIA FLOW 18111 fll] 6 2'CSO]DIA POWER S:PPLY NNOCNOUT ,,11,, 487[.0/ 4' 318 U 118 4 - tiCy}ALL VIEW DRAIN USING 3RD ANGLE 110511 13711 C ' 31I' (S71 DIN GA:6E ACCESS PUS tT"- 33-318 D MI. 1211 DIA FIELD CONTROL COINS HOLE 15481 E S/4"-I4 NPT CONDENSATE DRAIN F '12"-14 NPT GAS CONNECTION - 0 2 vt' 1647 DIA POWER SUPPLY NV/CA-OUT 32-814. (CCNONIIER MOOD + 18181 (OPTICNALI 16 FILTER ACCESS PANEL• [4067 :TOOL-LESS: 25-518 ACCESS . CONDENSER [6571 TXRU-THE-BASE CHART i•PANEL I RETURN AIA TRFSE HOLES REQUIRED FOR USE j A1lj -� CRBTNPWi001A0'. 0034.0' R COIL ACCESS PANELI I 1 • 1 THREADED WIRE SIZES HOLE ` COINBEA 517E USE SIZES INAs.7 41, ® I i( (/ \\� 41111. W 117' ,15v 718' [U 6 _ 17(!((/® 11, yl [2177° C 2' 24V 6' [12.27 [4►Iim�E� ��- RA Y A 3f4' POWER • IIB' [18.61 -��•itril 44 • III\\ n,,,7 � v V 1 }- ATA 114 (ob3Abu 111^FPr GAs 1 I!a• E28 61 2-5/8 • BACK 1617 s'_ ����� P �— FOR"THRt-THE-BASEPAN'FACTORY PPT7oN. TTP \ `/% E ALT _y r i]iTINGS FOR ONLY N,i, 6 2 AAE PAOYI DED CUR8 \ CONDENSATE • SELECT EITHER 374"DR 112' 1I q DRAIN OPENING I7-314 29-318 FOR POSER. OFFENDING 01(IRE SIZE WIDTH 1 8\ IN BASEPAN 1751] (14171.1 1 SUPPLY 26-Il2 44 10014.01': PAOACDES 3/4' FP,TIRO CUR? 18-118 T 1 AIR 0673] ;;fry, FLANGE d(ITTIrG. 14555'6-v8 '1-1/4 12-1r4' - i 14111 13631 13111 t ' S[E TNRU TXT 6.114 t i ! � ` BAS[•CNAi,�. ..1 .. .(,5t: y J /� �'- �fLUE (3]11 SEE DETAIL 13/.- -_ 11101 O00 TOP '-- '8-112--•. K 4-5/8 SHEET S 4I 25 16361 [4101 E STD 1',81 CONDENSATE 10-'!2 I '/4 LECTRICAL DRAIN (1651 (31] ' DI SCCNNECT• �+ ..1 -- LOCATION .• I[638 1 COADEN ER -(u J�� COIL II CONTROL 904. INDOOR 3LONEA ACCESS PANEL ACCESS PAYED ' 25-1/8 IL1EA OPTIONAL • I 16-314 • [At t] AETN Ly AIR 7----f ` FACTORY I • F... ANDLE 11-378 `.. SUP>_JI I 4 - INSTALLED 'I• corvENlExtE • 191/2 O ! Nti �� AIIP.- ' i� 6-518 [181] H__ 1'-111 R ® E'687 I4O0 r- [5397 3-314 --�� 1957 46-3!4 HANDLE 8-318 [1181] E1647° 12131 [,11] 6 6-518 14-318 [169] 26-718 11511 118887 16821 BAROMETRIC 31-ill RELIEF LEFT 11937 Flow SAPFROST AIRPLR4 116 RETURN RIGHT AIR ITC CLASSIF[UTior I 2S OF T5 I 8-244.7016 3TE ,16R`EDEs 2315 481C 04-07 SIBOLE ZONE ELECTRICAL I I RIO U.S. ECCN:NSR48TH500993 H Packaged Rooftop Builder 1.46 Page 34 of 43 Certified Drawing for 6 ton Project: -Untitled! Prepared By: 05/10/2017 06:28AM � EirC8R4is ieWV4FYEgCa4i..MURK•m NaMnR1+WnMMnKpSTD GAIT ORNECORNER CORNEA COATER Carw+m0l niTin COM..C.G. REIGNT �4Y1•Uxir 4 WEIGHT OUGHT/3/ WEIGHT ,81 WEIGNT ClICI WE1091 IDI L35 AG 165. FG. L85. NG LBS. NG LOS. 70 F r 1 48TCD414 480 218 402 46 P7 53 739 63 127 55 39(9911'25(6351 16 3/8 14.67 48+CDA:5 52$ 139 S5621EIG 26 57 136 57 737 62 44 63 37(9651 24 16101 IT 14341 48TCD606 560] 2557 4 ?26 57 136 62 155 r0 u 65 36 19651 i4 16101 17 III[1367 �---------.----..—..—._—_—.---.—_.i 48TC0617 652 296 '5] 68 169 76 176 80 157 71 39 19911 13 15811 20 198 15•'7 I BACK N7 IS NITH LOW GAS HEAT 440 CUM PACKAGING ECONOMIZER FOR OTHER OPTIONS AND ACCESSORIES. REFER TO THE PRODUCT DATA CATALOG. BACK 8174i - 1 i WITHOUT ECON0MIZE3 O • PTIONAL 0016 ^ • ((040310679060 CORNER A CORNER 8 — 0 • /,,7r~\\\\ I I '/1111111/! \\ 111111!!/,, 7 I ! 111\'\ _ �f NIGHT --i -- LEFT d CORNER C I __ F III--- [ CORNER C 14-5F8 116961 FRONT TOP 1 • = T I IINOTES 0 2 1. FOA ALL 616(5/U CLEARANCES LOCAL COTES OR J:RISDIC11095 NA!P9(Y4IL. sw (,400 L I 'I I.: : 000. RISME N uJL s ln11 aP8ATA0 SUI�AG! CQOUCTM BM®I NONCQOUCTNE BM!R CLEARANCE FRONT FRONT 48 [12191,1,] 36 [914,861 18 [457mm] LIFT 48 11219mm] 42 ['067r6r( 18 [457661) BACK 48 [12197rm] 42 ['067mr) 18 [457mm] BACK 11/114000 36 (9141,111 36 C9141661 18 [4578m] RICHT 36 [914mr) 36 (914mm] 18 (457m81] TOP 12 [1829m] 12 [!829111] 72 0829mml ITC UC.SLA ECC NC NSR I 36 OF TS I DATE I SJPERCEDES 3-16-2015 I 48TC 04-07SINGLE 5119 135 HFATTR ICAL I 4816500993 RH° Packaged Rooftop Builder 1.46 Page 35 of 43 Certified Drawing for 6 ton Project: -Untitled1 05/10/2017 ,.....,„ O ' Prepared By: O6:28AM Service Clearance H C05337 LOCATION DIMENSION CONDITION 48-in(1219 mm) •Unit disconnect is mounted on panel A 18-in(457 mm) •No disconnect,convenience outlet option •Recommended service clearance 12-in(305 mm) •Minimum clearance 42-in(1067 mm) •Surface behind servicer is grounded(e.g.,metal,masonry wall) a 36-in(914 mm) •Surface behind servicer is electrically non-conductive(e.g.,wood,fiberglass) Special •Check for sources of flue products within 10-ft.of unit fresh air intake hood C 36-in(914 mm) •Side condensate drain is used 18-in(457 mm) •Minimum clearance 48-in(1219 mm) •No flue discharge accessory installed,surface is combustible material 42-in(1067 mm) •Surface behind servicer is grounded(e.g.,metal,masonry wall,another unit) 0 36-in(914 mm) •Surface behind servicer is electrically non-conductive(e.g.,wood,fiberglass) Special •Check for adjacent units or building fresh air intakes within 10-ft.of this unit's flue outlet NOTE:Unit not designed to have overhead obstruction.Contact Application Engineering for guidance on any application planning overhead obstruction or vertical clearances. Ouuu 1-2 Packaged Rooftop Builder 1.46 Page 36 of 43 Certified Drawing for 6 ton Project: —Untitled! Prepared By: 05/10/2017 0628A Ceistrfll�'�1s 7a:RAn a n[rwnn m[.Rt1AR[Nra•nN ANnf510R 9r TE",'''',"'N 9 c,n;S (OYR�IS�ILL 401�![NTI1(lM[CC04 KED moat moat q[R ."RO1 MIT:'fm rnr9R.,N .QCR11.....[NrN•T1CYA MM.;Nutt. •CHrPtt[or INrR•Q. '.. 11-116 ..r 1180).31 .1X3136 TIE 9ASE RAIL 6 581971 • M o 0 . _� 41-1/4 \\ •. 117!6.51 0 IInsIOE THE SASE FAILS ./..--...-.<1 041 1,' \ I /� ..1-114 �� / , [571 O.' INSIDE BASERAIL DIMENSIONS II , 3„ `� I 1 /� 1-+7eAil Ual L . 148] \4,14t�1�. BOTTOM 4/r4Ea' I_ 1-318 3-.14.— 1361 (251 DETAIL C (821 TTP 4 PLCS i81 —+ 3-718 1991 Pl ALTER ACCESS PANEL CNA 1 C0XT90L 809 ITOOLCESSSI CON3ENSER I ACCESS PANEL INDOOR KOREA ACCESS COIL I ACCESS PANEL i 0 { ill • INDOOR COIL 1 Q - ACCESS PANEL ® i 11111 1-716 SEE DETAIL C a 0 1 r ► T- rig 1 t_.r 1 ad ■��..���� f • 1 (-7.61 amimia■ 1 1 r Wil_ I T 1 t •, 1 \ 2-318 BACK 3-1N — LEFT rot.71 ER".SI -3/8 TAP CJR9 .6C 11 WIDTH 59-316 11509.31 FRONT TC (N.S`A ECCNCNSIRN I 4S CF T5 I 8-24A72016 3-16-2015 I 48TC D4-01 SIGLEC00LING N*ITN2ONE ELEC CAS NEATTR ILAL 4878500993 I RHv Packaged Rooftop Builder 1.46 Page 37 of 43 Certified Drawing for 6 ton Project: —Untitled1 Prepared By: 05/10/2017 06:28AM Ge•+rN++br:�NINlNI aYrsOYar.Ks Tu.Ia1nVn{CCmu+•on A vnOwLpw ser Mnc1IaKW . mO1pIxsl+141+1MP704 u I ... ACCxnANCC 01(GNpACT. TM-THE-SASE CHART THESE MOLES REOUIRE)FOR USE CR5TMPNROOIA0', 103411 THREADED MIRE REO'D MOLE 7HFU-TNE-395(CNAR7 CONDUIT SIZE LSE SIZES IRAO.) iHESF HOLES AEOUIRED FOR-SE N lip 1150 1/8" 022.27 CRBiMPNR001A01, 003801 x 1/2' 242 718' !21.27 THREADED NINE RED')HOLE I 3!1' POWER 1 t!8'028.67 CONOT SIZE USE SIZES(NA4 1 ZIA (00310'1 1/2"FPT GAS 1 I/8' 128.61 N 112' 1156 7/8. 022.21 TOR"THRL'-THE-SASEPAN"FACTORY OPTION, x lir 2/4' 2/Y 718' [22.2] FITTINGS FOR ONLY ,Y, 6 1 ARE P802(DE) 1 )f1' POW 1-I/N' (28.61 1 SELECT EITNER 3!/'OR 1/2' 21 1073801; 112'FPT GAS 1-1/B" (28.61 1 FOR POND. GEPENDIIG 09.120 SIZE FOR 'THRU-TME-9ASEPAN' FACTORY 001109. IA 1001A0I1 PROVIDES 311' FPT MU CURB FITTINGS FOR ONLY x, 1. &7 ARE PROVIDED FLANGE b fITTI9G A 10118111 PROVIDES 311'FPT TSR[CURB ________ ____ FLANGE 6 FITTING. /i \ NI I T II I F • I I —'�-- _ • j • Zi 16-tel 11111 ��./ 7 I I I I I1 I - Ii'I IIII ifII III 11-I/ 2 18-118 28 11-1l4 • Zr' • 11100.0ploix 03631 1-1Y7 131811 12911213127 1 . • 10- 1256/8 1 • • • • • • • - - I I I I23 IAx 25367 1 I I I 21 44. 160311 I II II 25 15II omit. 1 1 [6IS] ^ ) 1 FROM SHEET 2 1 DETAIL E FROM SHEET 1 I I THIS VIEW REPRESENTS PRODUCT BUILT PRIOR TO 1 /1/Il THIS VIEW REPRESENTS PRODUCT BUILT AFTER '/1 /17 ITC UC.S. ECCNCNSIRN SS CF TS 8-24-2016 3-16-2015 4870 04-07SINGLE NNITHZONE GAS HEAELECTRICAL 48111500993NEV Packaged Rooftop Builder 1.46 Page 38 of 43 Performance Summary For 6 ton Project: —Untitled1 05/10/2017 Prepared By: 06:28AM Part Number:48TCDA07A2A6-0A0A0 ARI EER' 11.00 11.22 Base Unit Dimensions Unit Length' 74.4 in Unit Width. 44.0 in Unit Height 41.4 in Operating Weight Base Unit Weight 652 lb Medium Static Option(Belt Drive). 10 lb Total Operating Weight 662 lb Unit Unit Voltage-Phase-Hertz- 460-3-60 Air Discharge' Vertical Fan Drive Type. Belt Actual Airflow. 2100 CFM Site Altitude. 0 ft Cooling Performance Condenser Entering Air DB. 95.0 F Evaporator Entering Air DB. 80.0 F Evaporator Entering Air WB. 67.0 F Entering Air Enthalpy 31.44 BTU/lb Evaporator Leaving Air DB. 56.0 F Evaporator Leaving Air WB. 55.8 F Evaporator Leaving Air Enthalpy- 23.64 BTU/lb Gross Cooling Capacity 73.68 MBH Gross Sensible Capacity 54.42 MBH Compressor Power Input 5.10 kW Coil Bypass Factor 0.070 Heating Performance Heating Airflow. 2100 CFM Entering Air Temp. 70.0 F Leaving Air Temp. 96.0 F Gas Heating Input Capacity 72.0 MBH Gas Heating Output Capacity 59.0 MBH Temperature Rise. 26.0 F Thermal Efficiency(%). 82.0 Supply Fan External Static Pressure. 0.40 in wg Fan RPM. 1189 Fan Power 1.14 BHP NOTE. Selected IFM RPM Range: 1173-1518 Electrical Data Voltage Range. 414-506 Compressor#1 RLA. 9.7 Compressor#1 LRA. 62 Indoor Fan Motor Type. MED Indoor Fan Motor FLA. 4.2 Combustion Fan Motor FLA(ea). 0.25 Power Supply MCA. 18 Power Supply MOCP(Fuse or HACR). 25 Disconnect Size FLA. 17 Packaged Rooftop Builder 1.46 Page 39 of 43 Performance Summary For 6 ton Project: -Untitledl 05/10/2017 Prepared By: 06:28AM Disconnect Size LRA. 100 Electrical Convenience Outlet None Outdoor Fan[Qty/FLA(ea)]. 1 /0.8 Electrical Data(Units produced on or after 02/09/2015) Compressor#1 RLA. 8.2 Compressor#1 LRA. 66 Power Supply MCA. 16 Power Supply MOCP(Fuse or HACR). 20 Disconnect Size FLA. 15 Disconnect Size LRA. 104 Electrical Data(Unit produced on or after May 18,2015) Power Supply MCA. 16 Power Supply MOCP(Fuse or HACR). 20 Disconnect Size FLA. 15 Disconnect Size LRA. 104 May 18th and beyond units can be identified by serial number 2115X)000000O(and higher Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage Acoustics Sound Power Levels, db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz 87.0 86.8 88.8 125 Hz 82.2 78.9 81.8 250 Hz 75.1 66.0 76.9 500 Hz 70.9 63.4 74.4 1000 Hz 67.6 62.8 73.3 2000 Hz 61.7 56.9 69.8 4000 Hz 63.4 52.7 66.3 8000 Hz 59.0 45.2 62.7 A-Weighted 74.3 68.7 78.0 Advanced Acoustics o 1 o z> --= iti 1440 • o ° Advanced Accoustics Parameters 1. Unit height above ground. 30.0 ft 2. Horizontal distance from unit to receiver 50.0 ft 3. Receiver height above ground. 5.7 ft 4. Height of obstruction' 0.0 ft 5. Horizontal distance from obstruction to receiver 0.0 ft 6. Horizontal distance from unit to obstruction' 0.0 ft Packaged Rooftop Builder 1.46 Page 40 of 43 Performance Summary For 6 ton Project: -Untitledl 05/10/2017 Prepared By: 06:28AM Detailed Acoustics Information Octave Band Center Freq.Hz 63 125 250 500 1k 2k 4k 8k Overall A 88.8 81.8 76.9 74.4 73.3 69.8 66.3 62.7 90.1 Lw B 62.6 65.7 68.3 71.2 73.3 71.0 67.3 61.6 78.2 LwA C 56.4 49.4 44.5 42.0 40.9 37.4 33.9 30.3 57.7 Lp D 30.2 33.3 35.9 38.8 40.9 38.6 34.9 29.2 45.8 LpA Legend A Sound Power Levels at Units Acoustic Center, Lw B A-Weighted Sound Power Levels at Unit's Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp D A-Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. FanCurve 20 -V 1 2lliR i 1.8 15- 11C0130 61.4 =1 \ \X12 IiiL 7 w 1.0 \ \ \ 00.8 \\ N Ob 3713 P r 2A-F 04 1 - 5 \ 1-P \ A 0.0� 7 L=__ I 1 11 \ -L.J.:�- 11 _�.I J 11 0.0 d3 0.6 0.9 12 15 1.8 21 24 2.7 3.0 33 Airflaw(CFM-thousands) RPM=1189 BHP=1.14 MaximumRPM=2100 MaximumBHP=3.70 Note:Please contactapplicationengineering forselections outsidethe shadedregion. SC-System Curve RP-RatedPoint Packaged Rooftop Builder 1.46 Page 41 of 43 Unit Feature Sheet for 6 ton Project: -Untitled) 05/10/2017 Prepared By: 06:28AM Carrier WeatherMaker` — 48TC PACKAGED ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS 3,4,5,6,7.5,8.5,10,12.5,15 TONS STANDARD FEATURES INCLUDE: • Puron(R-410A)l-WC refrgerant •ASHRAE90.1 energycomplant • Sao/compressors with internal break and overload protection • Single-stage cooing capacity control on 04-12 models • Two-stage cooing capacitycontmi on 08 16 models +•+s.. rid • SEER'supto13.D.EER'suptoll.1and lEER'supto11.8 ¢ x •Acutml•'refrigerant metering system ¢1 . • Exclusive noncorrosive composite condensate pan in accordance with • a t t a ASHRAE Standard 62.sloping design,side or center drain • Standard cooling operation up to 115'F(46'C)and down to 40'F(4•C) - down to 25'F(-4'C)with winter start kit. • Pre antedexterlor panels and• p primer-coated interior panels tested to 'wore 500 hours sat spray protection r • Fully insulatedcabinet- • Exclusive IGC solid-state control for on-beard diagnostics with LED �;ry error code desgnationbumercontrollogic and energy savngndoor O.1 fan motor delay • Low NOx models that meet California As Quaky Management Optional Louvered Hail Guard ShOSi • Induced draft gas heat combustion design • Redundant gas valves with up to two stages of heating • Low pressure and high pressure switch protected. IISHRA!R41110 MAINTENANCE FEATURES: •ra • Access panels with easy grip handles �/�„ Innovative easy starting. a no-stop sews on unit access panels .♦ n. •Two-inch disposable return air filters and Tool-less flier access door COM •Direct Drive ECM on 3 to 5 ton(-5 voltage only)models and belt drive evaporator-fan motor and puley combinations evadable on all models •New terminal board facikatng simple safety circuit troubleshooting and WEATHERMAKER SERIES smpifiedcontrol box arrangement WeatherMaker(48TC)units are one-piece gas heating,electric •Exclusive IGC soid-state control for on-board diagnostics with LED error code designation.burner control logic and energy saving indoor cooling units that are pre-wired and charged with Puron fan motor delay. (R-410)refrigerant. They are factory tested in both heating and cooling modes, and rated in accordance with AHRI INSTALLATION FEATURES: Standards 210240 (04-06 sizes) and 340/360 (07-16 sizes). •Thru-the-bottompowerentrycapability WeatherMaker units are designed in accordance with UL • Single point gas and electncconnections Standard 1995,and listed by the Underwriters'Laboratories. • Ful perimeter base rad with buitin rigging adapters and fork slots • Field convertble fmmvertical to horizontal airflow for slab mounting. (16 size models require field instated supply duct cover) Approved and certified by: STANDARD WARRANTY: • 10-year heat exchanger—15-yearstainless steel option Mit CERTIFIED- • 5-yearcompressor C (120 • 1-yearparts US �,,,,u,.,,,,,,W,�,,,,.,,, • • 3-year parts on Novation Condenser cods—where evadable ruw...w..v..• • Many optional upgrades also evadable �vMe[tvw t ""•"`' OPTIONS INCLUDE BUT ARE NOT LIMITED TO: .. :X,n rm • Premertnk'•r and RTU Open Huai-Protocol DDC Controls .w.v.a. • Supply and Return Ar Smoke Detectors.high static motors C(illUS • Louvered condensercoiguards • Economizer.disconnect and convenience outlet options • Stainless Steel heat exchanger option • Corrosion resistant cot coating. Certified to ISO • I4umdr-tAAZer`adaptive dehumidification system available on at models with RTPF condensercois—Motor MesterI controller included • Hinged access panels re a canpsr$list aortas am a cwsotac rely n M hrooci Diva Caoog lx tea eat Packaged Rooftop Builder 1.46 Page 42 of 43 Project: -Untitled1 Spec Sheet for 6 ton 05/10/2017 Prepared By: 06:28AM Packaged Rooftop Builder 1.46 Page 43 of 43 STRUCTURAL CALCULATIONS FOR F e JEVO Bu��ur ,JUL I 7 2017 Cale vARD klD16100 SW 72nd AVE $ioN TIGARD, OR 97224 -- ROOF MECHANICAL UMTS -- ot PRO, 1 r, fAl 14 O' ON 4.4, . NOR'°.- EXPIRES:12/31/18 I Contents Details A-H Dl -D9 Gravity Calculations G1 -G5 Contact Person: John E Nordling,PE Lateral Calculations L i -L3 Enclosures Elm-I:139 NORDLING Proj. No.: 17- 6 4. ‘,,,Eas)0, STRUCTURAL ROOF MECH UNITS ENGINEERS, LLC PAC TRUST 6775 SW 111th,Suite 200•Beaverton OR,97008 Date:JUN 2017 By:JEN Sheet No.:COVER 1 0-z:4.-e4ic C) 'a-4 -7 0 __I' .. ,. • ! at 4-t C.o..• 1 . I _ ______ 1 / pi i 4. f i , i ) • - _ .._..,--- 0-, I ..9 i 1: I ! _ • _L ,,,, V .-F ' --7 I / I .,--- B )- I ,AIN 1 1 ' (AS NW 7.1 .5, 0 0 :-_-„, ....._.__ , „tin f _ '*.S1 r vi i , , _\41 i f ------.---:-------,-- -i i li 1 / , ?T GS 0 ...ei- ,,_, i Ii 1 , '., . '' I 1 '' —4' .: 1 / • '', I - .:H HI -• (Ort : 115'4': , . 1.-' ,i i n Co [ , . . .t.------4-4---- -H-- -1sfr. (0'0 ...„....._______, , Ili 0 1i • . ' ' " ...............m.. /0 - ,,tz PRoF ,0INE'e /e2 - 12,1; , . . . . Aid ft *-EGON to ti 0 .. . -- — - ! , : I EXPIRES:12/31/18 I NORDLING Proj. No.: 17-156 STRUCTURAL JEVO : ,t, 1 ROOF MECHUNTIS ,r : ENGINEERS, LLC PAC TRUST 6775 SW 111th.Suite 200•Beaverton OR.97008 Date:JUN 2017 By:JEN Sheet No.: 1 _ . --,..) TT , ! I .); Ill ' HI 1 I 1 j ' , ' I i . 1 1 , ,;!11 I fr ( i 1 1 j,,,, ,! .tr r•-•-"t / VI 11: t irr 14: i 1 I •= ..) , L6 I I A 3 i i 01 I ,e•' ,n eJ ji , — 1: el' i -.3- I i 4 I I ' • 1, ':1•t ,;I 1 ,,„ 4 31' \ I ,1------1,-- i 1 i i! , , i I , i I I 4 , '[ .3- i ,I i f 0 4-! i 11 1 -1 I01 I . - , 1 i I I , . \ 6” ,....j_____., litet•"-tois‘k "1„..r.y..-1::› - IA ,-Cat / ../ gi 3,u,.., t...,,,,, ...• 5Es c) C) g • ,is) Po-, / 2187 , S. 6- ''--- OREGON I0 ,... '6'4 A.-C'5 6%v \ . NoFtv. --) EXPIRES:12/31/18 l ; NORDLIING Proj. No.: 17-156 ,/,) : STRUCTURAL JEVO ROOF MECH UNITS IC ENGINEERS, LLC PAC TRUST 5775 SW 111th.Suite 200•Beaverton OR,97008 Date:JUN 2017 By:JEN Sheet No.: P 2- ______i , , , _ ___ ___. _ 1,7 . 1. ..,„;), , „.,.,+.7_,(i. . '7 t �k Y K__T ► 4 �'�SMfls ( � � ) il I I �I �t3S a I 113 I vPX... 14-ofj i f 5trA zjcr.9 `L✓SZt1---Z IV/ • + A . - i \ I / i ' , li 1 ff 'Stat t E � � 4 AX'JGTdr. .kms.Cops t: + t _ �tStMQ3s ,L3 .. Y f (�. /de/ t If it \ / I. Ustla t, 3-!I" f fie, !I f I /it,..7 . ----- \ f. s6r- tT+ro �Y, i . , \y w►i t,sr foga I . 1 I IN - / _ . • / \ . -- f - 1-- - '''', -1- - . -f M I E_„ f ' , _ • • v-i.\ - . 1 QED PROF (��1 I `Cj��0NG1Ne . /O / t (,e)t.t-t� tt. 'f`t?. //// -- 12,187 tf/. 514,0- • • -; r 'r- , -4 - •REGON , "r'''P L-7-i4-C7 C) ✓O J�E 15, 1989 i y� NORo�``�c� i I EXPIRES:12/31/18 I NORDLING Proj. No.: 17-156 ` STRUCTURAL JEVO ROOF MECH UNITS -41154 ` ENGINEERS, LLC PAC TRUST (1775 SW ll 11h.Suite 200•Beaverton OR,97008 Date:JUN 2017 By:.TEN Sheet No.: d3 ------ -- - --1' - 'Ii f I . I\ i,I, 1{ , .c-------7Th j I 11 sa.-. © F-cd. 'Az.q...g € . -----•1 k. j I 1 I i i ° 1, :,1 \I 1 / 1 ultdr. I li F f - i � _ -_ , L= -6/ \., 1\ 4 I ' ' t 4 P ka` t` 1 a ;' \! ( I 1 (! - �ED PRQFF /,�(y 0 , N. ENG 1 N FFA /67 �...)6 .moi U 12.187 1 ¢ I l id O'EGON 11 rr‘, -)--) \1-1-1'‘c - ?LArt....t _ -0 ,- i5, '9 •P Z 4'41 • NOR° I I EXPIRES:12/31/18 I NORDLING Proj. No.: 17-156 STRUCTURAL 1Evo li ROOF MECH UNITS 4 ENGINEERS, LLC PAC TRUST 6775 SW 111th.Suite 200•Beaverton OR,97008 Date:JUN 2017 By: ,TEN Sheet No.: D 4k.. • f-------_______ 1E 617C17-0.. S4--- v, 'T - *( 1...C.'-`'4\ r.' _ ‘,..:1:-. _y a(SDI .. a ,fR 1 ...,.., .....i , I ! t;-c --. , . ! _ . . 7.___________ _ . i ...........)".....„1/4_ • • j tom' , W r ',.1 Z _– -_ wir LAN:41r4 4V-0" . �_�— (..110-r s �r o i rA\k i PRace• �, 1 18717. ORE ON 6 .. . ,.. -rokt vnTfT O < ts, ' � \ayF. NORo\- EXPIRES:12/31/18 NORDLING Proj. No.: 17-156 fl r. f STRUCTURAL JEvo ENGINEERS, LLC ROOF PAC TRUST Date:JU & CH UNITS P 8775 SW 11 lth.Suite 200•Beaverton OR.97008 N 7_017 By:JEN Sheet No.: 495 • • „7,_ro _,—r7=.., ..•.....„ i 4 %-i-- . _ . ,,,,tc.trc-fr I 4'r-+ 1 ... . i , / ...1_:.. ;� E Z r---7.— 1 ? r UG r4 v,1t'f' GJ;k7, IS4M- 40-$/ Ell-04- f5(iv§esi 'Los (Jrrr cam 3`-� (30iM ✓i -- t,o7 D PROF� �,� \ GINEi Pr t ,>se,C,WI .� 1 187 R Ptt',s'NM.>kJ\ortf.- 01 Zr - (1--- —_ - -- •- ,O \ OREGON /' vO t k 15, �0 0'S' . NOR9 1 EXPIRES:12/31/18 I NORDLING Proj. No.: 17-156 STRUCTURAL JEVO ROOF MECH UNITS 4:t1ENGINEERS, LLC PAC TRUST 8775 SW 111th.Suite 200 Bew crtun OR,97008 Date:JUN 2017 _.__By:JEN Sheet No.: 12(0 , . .. '1 e.,---.--c-0-- i „ .... ._ ec,A--,..:zAc ___....___.___....„...*-- 1 (-- Ci-t 4 D �; / I 1 ! 4 -�____- ;• !u A_Li 6,S k..1 Ft t'C CO(Le I_____L W.a.- 4-•-3; C 6=44 • Si-CC)�) (J.r ¶ vet t t' r %ser := GGtae- A `t��4D PRO r ('? S 6NG i N,„ /O t,v iG`? - 12, 87 - - - _________:_,...........;. ..,..1t' �(}- ,,q-F � - �...�..�.:_,.Y...as......_ GREG+PJ • F i 61 0)..t \ / . NORO EXPIRES:12131 118 ISNORDLING Proj. lVo.: 17156 STRUCTURAL JEvo _ ENGINEERS, LLC ROOF MECH UNITS PAC TRUST 6775 SW]lith.Suite 200-II (—non OR.97008 Date JUN 20J7 By:JEN Sheet No.: VI . T • r, ____________ ___ . _.....,,..,___...____________ 6,,014.\,, _____c_r______r_____„_41_1 1 ,I 2 4. © .. O 7c5zjtrt Gf Gt. gikt- fly, - \\<\/ , i NLite4 cR IT Ckri..13 . F 1 j r . " ,.-. I i 1 4-f-a `41Sta sa 'c..VS fa t+ . kt,.Stt+ c..'� Uc1 t of I _______- (01.r. W1130 - CI"-i t �f st • {.Z} ( lx. kkti� W.\CSLAr>fl tt,U(✓ Wm' �.kt3 Ci7f !• FJ LkI (.2.4-4.5.1\k, Berraco. .-rt, c Croom v.st:t S �o.D PRoire ce tt � w ,t( t cop,>)3s er `44),A.�� f „ �, ,. .,t s 01 it , �Nti t N„.. , tilt (Vet.KO'. 5.t 04n,...1 t(.`). Ts Cal`34t- . ,{} Ucaoc. ��_ ---- 41_.: OREGON , _ e IS ¶O It l}NY t T - .. - C v G<Y t 5. 1995 �O �ti4/ - NOW' I EXPIRES:12/31/18 I . NORDLING Proj. No.: 17-156 STRUCTURAL JEvo ROOF MECH UNITS ENGINEERS, LLC PAC TRUST 6775 SW l l lth.Suite 200•Beaverton OR.97008 Date:JUN 2017 By:JEN Sheet No.: QS (4)KSSTCEERLEWBSRATOCKCEUTRSEW4/ ((44)) 11100 xx TEK SCREWS TO UNIT BASE RAIL ilskik 0 _.... ir-IECHANICAL UNIT—, UNIT BASE RAIL fie (4) *TO SCREWS ... STEEL BRACKET--2 .12 WOOD SCREWS 612o/c,------ 1-1 fi ' TYF' UN.O. LEVELING CURB (AS REQ'D) F-Th ------ FLASHING 4 ROOFING BOTHERS -- " ---_-____, Y 115p---0--- (4_riii- __=____ ___=___ 1 i . - --1 • 1 (E) 4xI6 BEYOND REINFORCE WHERE NOTED ' (E) GL GIRDER Se PROire e‘G IN /a fr;. .., 121 ...1,„ 4 OREGO 0 0 DETAIL EXPIRES:12/31/18 I NORDLING Proj. No.: 17-156 STRUCTURAL ROOF MECH UNITSI: 4:,_, 1 4 1 ENGliNEERS, LLC PAC TRUST 6775 SW 111th,Suite 200-Beaverton OR,97008 Date:JUN 2017 By:JEN Sheet No.: Cin:-o 'DA-c.:?...c -~,�---f--' �I 0 yJ( moi, / \, #_- Li 4 - , Atiw kJi1 a C,;(u,-r ! 6,`;it. , tiC=9 0----:- —'`�— fi:Jt i ri — I (ft, (-11,111" ,tnr-- fii' , _ Ir;J7f '_tom- fy.`7,4 OD (P 1-Dkt ONYIT (C.,• • • h G1 .1.4''')2�.5 ('(9 ,"- Lt5V 1,1"r 1 4 4rtC. y (,1S 74- Nvi`` b .�,4- 1 .1 . _, y,pn 4 - L ac` 4-rVG 17F -l. Fti (Sao IX ST ,I,N� cT- i NORDLING Proj. No.: 17-156 u5c STRUCTURAL JEVO ROOF MECH UNITS ENGINEERS, LLC PAC TRUST 8775 SH'Huth.Suite 200•Beaverton OR.97008 Date:JUN 2017 By: JEN Sheet No.: 1 ........ ....,, T a't.,(,=--/%___ .____ _.1 1 i = 32S ; , ) ; .f. __4,_(.... .i• / sod A , , , - 1.-.., 2.7-15 ------='—rr---'' A .5 1 -...L ,-- , i ) , ,> , • _____---I) --41:115-74 _— tivir r i' --- SI.La (jti:-; (.1. ,,r4 Ufa I( (. 71•4 ... . Lrr../4- –7,c To.1. 0 r• i 1" „,....,...2 „„ u.e } 5TFc ? C.,). "r” tk v-(1,4• C t 0 r (,- ,..---1-c 'e&"‘D(1):ra. _.........4 ,c 1:15' cv- 't. - t5©fbetil) NORDLING Proj. No.: 17-156 ti5 c STRUCTURAL JEVO ROOF MECH UNITS ENGINEERS, LLC PAC TRUST fi775 SW 1 1 1 th.Suite 200 Beaverton OR.97008 Date:JUN 2017 By:JEN Sheet No.: ..?0 ' ,Ii ,' : li t I IV ; j; J1 /I .P ri 1 ` i ii !' 1INi Ij i; • i {ti 3 fit; , 1 �cl i f1 i4--\--i. I - -i I 1 i_. "S I lin :1 J - ' !i -S- I ",I it +i y t/l D'' 1 d- I .... ... ' i t !; Ii,3T srt 1y:�i N �, r / 1 / c I C II I 1 , , I a i Jf / ; i ; 1 I 1 I r 1.1.-t-L-. f t� �-t"o - 2itF� ,i 3T,,s 0,4,-c- ® @ 3� (®;v t...) ........*-- tb C46-Jr Vu:s)' ,79 >i Sif-, ® v_it-",--,,.....„4,:,.5(.1,..41r .,..;," fogst2 \ 4 AT 0 .1 ..1-- yt, C. 4\,, ) '''• 2 r p„,_ csgy 3zs 4t 1 'f p>CfS� �4 �`4t�t i0 - .C._............::\)--NORDLING Proj. No.: 17=156 115( STRUCTURAL JEvo ENGINEERS, LLC ROOF MEcx uNlrs 6775 SW1110).Suite 200•Beaverton OR.97008 PAC TRUST Date:JUN 2—--2017 'BY:JEN Sheet No.: (r73 Nr rdting Structural Engineers LLC 6775 SW 111th, Suite 200 Beaverton, OR 97008 Date:06108117 Page: MULTI-SPAN TIMBER BEAM DESIGN JEVO-ROOF UNITS A-(EXIST) A-(UNIT) A-(COMB) B-(EXIST) B-(COMB) B-(REINF) C-(TL) GENERAL DATA - 1 2 3 4 5 6 7- All Spans Simple Support?? : YES Spans Length ft : 23.67 23.67 23.67 23.67 23.67 23.67 7.67 End Fixity: : Pin:Pin Pin:Pin Pin:Pin Pin:Pin Pin:Pin Pin:Pin Pin:Pin Beam Width in : 3.500 3.500 3.500 3.500 3.500 3.500 3.500 Beam Depth in : 15.50 15.50 15.50 15.50 15.50 15.50 7.25 CALCULATED VALUES -OK- -OK- -OK- -OK- -OK- -OK- -OK- Ph-Modified Allow. psi : 1676.6 1676.6 1676.6 1676.6 1676.6 1676.6 1345.5 fb-Actual. psi : 1589.1 45.6 1615.6 1589.1 1654.7 1404.7 431.7 F'v-Modified Allow. psi : 207.0 207.0 207.0 207.0 207.0 207.0 207.0 fv(actual)*1.5 psi : 77.5 4.7 82.1 77.5 84.7 71.9 28.6 Moment @ Left k-in : 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Moment @ Right k-in : 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Max.Mom.@ Mid-Span k-in : 222.7 6.4 226.4 222.7 231.9 196.9 13.2 X-Dist ft : 11.83 20.51 11.99 11.83 12.15 12.15 3.83 Shears: Left k : 3.14 0.03 3.16 3.14 3.20 2.72 0.58 Right k : -3.14 -0.17 -3.31 -3.14 -3.40 -2.88 -0.58 Reaction @ Left DL k : 0.77 0.00 0.77 0.77 0.77 0.65 0.10 LL k : 2.37 0.03 2.39 2.37 2.43 2.07 0.48 2.72 0.58 Reaction @ Right DLtal k: 0.77 0.00 0.77 0.77 0.777 0.65 0.10 LL k : 2.37 0.17 2.54 2.37 2.63 2.23 0.48 Total k : 3.14 0.17 3.31 3.14 3.40 2.88 0.58 Max.Defi.@ Mid Span in : -0.957 -0.019 -0.976 -0.957 -1.002 -0.850 -0.066 X-Dist ft : 11.83 13.57 11.83 11.83 11.83 11.83 3.83 DESIGN DATA Le:Unsupported Length ft : 0.00 0.00 0.00 0.00 0.00 1100 0.00 Fb:Basic Allowable psi : 1500.0 1500.0 1500.0 1500.0 1500.0 1500.0 1170.0 Fv:Basic Allowable psi : 180.0 180.0 180.0 180.0 180.0 180.0 180.0 Elastic Modulus ksi : 1800 1800 1800 1800 1800 1800 1600 Load Duration Factor 1.15 1.15 1.15 1.15 1.15 1.15 1.15 APPLIED LOADS Use Live Load on This Span ? Yes Yes Yes Yes Yes Yes Yes Uniform DL plf : 65.0 0.0 65.0 65.0 65.0 55.0 25.0 LL plf : 200.0 0.0 200.0 200.0 200.0 170.0 125.0 Point DL it : LL # : 195.00 195.00 325.00 275.00 X-Dist. ft : 20.50 20.50 19.00 19.00 QUERY VALUES Location ft : 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Shear # : 3.14 0.03 3.16 3.14 3.20 2.72 0.58 Moment k-in : 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Deflection in : 0.000 0.000 0.000 0.000 0.000 0.000 0.000 V4.4B2(c)1983-95 ENERCALC Bruce W.Kenny,KW060914SL-A Nordling Structural Engineers LLC 6775 SW 111th, Suite 200 Beaverton, OR 97008 Date:06114117 Page: MULTI-SPAN TIMBER BEAM DESIGN JEVO ROOF MECHANICAL UNITS D-(TL) E-(TL) GENERAL DATA - 1 - -3 All Spans Simple Support?? : YES Spans Length ft : 24.00 24.00 End Fixity: Pin:Pin Pin:Pin Beam Width in : 4.500 5.125 Beam Depth in : 13.25 21.00 CALCULATED VALUES -OK- -OK- Pb-Modified Allow. psi : 1057.8 2593.6 fb-Actual. psi : 868.0 2175.8 F'v-Modified Allow. psi : 207.0 218.5 fv(actual)* 1.5 psi : 38.3 140.6 Moment @ Left k-in : 0.0 0.0 Moment @ Right k-in : 0.0 0.0 Max.Mom.@ Mid-Span k-in : 114.3 819.6 X-Dist ft : 12.48 12.00 Shears: Left k : 1.64 11.67 Right k : -1.53 -11.67 Reaction @ Left DL k : 0.42 3.60 LL k : 1.22 8.07 Total k : 1.64 11.67 Reaction @ Right DL k : 0.42 3.60 LL k : 1.11 8.07 Total k : 1.53 11.67 Max.Defl.@ Mid Span in : -0.716 -1.003 X-Dist ft : 12.00 12.00 DESIGN DATA Le:Unsupported Length ft : 0.00 0.00 Fb:Basic Allowable psi : 930.0 2400.0 Fv:Basic Allowable psi : 180.0 190.0 Elastic Modulus ksi : 1600 1800 Load Duration Factor 1.15 1.15 APPLIED LOADS Use Live Load on This Span ? Yes Yes Uniform DL plf : 35.0 300.0 LL plf : 70.0 600.0 Point DL # : LL # : 325.00 875.00 X-Dist. ft : 4.00 4.00 Point DL # : LL # : 325.00 875.00 X-Dist. ft : 16.00 20.00 QUERY VALUES Location ft : 0.00 0.00 Shear # : 1.64 11.67 Moment k-in : 0.00 0.00 Deflection in : 0.000 0.000 65- V4.4B2(c)1983.95 ENERCALC Bruce W.Kenny,KW060914SL•A .ASC,L 710 Standard ' _ >��' . =R6ofTopAch Unit Location 45°24' 13.93"N Ss and Si=Mapped Spectral Acceleration Values 122'44'57.87"W 16100 SW 72nd Ave,Tigard OR 97224 Ground Motion Ss 0.965 Si 0.419 Occupancy Category II Site Coefficients Fa 1.11 Site Class D F, Importance Factor 1.00 1.58 Height of Structure 20.0 ft SMS Fa* Ss 1.075 SMt Fv* Si 0.662 Design Category(SDC) D Sns (2/3)SMS 0.717 SDI (2/3)SM1 0.442 Air Side HVAC FP MIN= 0.3 SDS IP WP ap 2.50 RP 6.00 = 0.215 WP->*0. 0.151 0.4•a •S •I i FP= n DS n 1+2 .W FP MAX= 1.6SDS IP WP RP h/ p = 1.15 Wp->*0. 0.803 Z= 20.0 ft ASD FP= 0.36 Wp->*0.7 0.251 I Eq= 0.284W+0.2 SDS W W:Weight of Unit z= 24.0 ft Fp= 0.41 WP->*0.7 0.284 i NORDLING Proj. No.: 17-156 STRUCTURAL JEvo ROOF MECH UNITS � ENGINEERS, LLC PAC TRUST 6775 SW 111th,Suite 200•Beaverton OR,97008 Date:JUN 2017 By:JEN Sheet No.:1.1 t>,\ i 13 Ibs .> -QC). W: 125 lbs 4ht4iIWt7 Curb 14" VEQ= 0.044440 284* 7251bs+02*p,717*725 lbs EQ =2061bs+73 Ibs 2@6 lbs T=206 lbs *(14"+41"/9)/41" 111 ��111)1111111°1111. + 731bs/2 - 0.6*7251bs/2 C: S lbs = 8 lbs [0 Net Uplift] V=206 lbs (4) 'MN-PRG-HOLD' 16 Ga GALVANIZED STEEL BRACKET W/ (4) * F CURB le 4) "i@ x '/z' TEK SCREWS TO ROOF CURB 4 (4) #I@ x ?' TEK SCREWS TO UNIT BASE RAIL -ok- Height 44" Weight 400 lbs Length 48" Height 33" Weight 650 lbs Width 32" Length 74« 2T Width 47 Curb 14" 3T Curb 14" VEQ= 0.284* 400 lbs+0.2*0.717*400 lbs = 114 lbs+40 lbs VEQ= 0.284*650 lbs+0.2*0.717* 650 lbs = 185 lbs+65lbs T= 114 lbs *(14"+44"/2)/32" T= 185 lbs *(14"+33°/2)/47" +40lbs/2 + 651bs/2 - 0.6*4001bs/2 = 28 lbs Net Uplift - 0.6*650 Ibs 12 _ -42 lbs [0 Net Uplift] V= 114 lbs V= 185 lbs NORDLING Proj. No.: 17-156 1 ` 4. ' � STRUCTURAL ROJEvo OF MECH UNITS `� ' ENGINEERS, LLC � PAC TRUST 6775 SW 111th,Suite 200 Beaverton OR,97008 Date:JUN 2017 By:TEN Sheet No.:L2 Height 41" Weight 775 lbs Height 41" Weight 1,000 lbs Length 74" Length 88" Width 44" 6T Width 54" Curb 14" 7.5T Curb 14" VEQ= 0.284* 775 lbs+0.2*0.717* 775 lbs VEQ= 0.284* 1,000 lbs+0.2* 0.717* 1,000 lbs = 220 lbs+78 lbs = 2841bs+100 lbs T=220 lbs *(14"+4 1"/2)/44" T= 284 Ibs *(14"+41'72)/54" + 78 lbs/2 + 100 lbs/2 - 0.6*7751bs/2 0.6* 1,000 lbs/2 = -21 lbs [0 Net Uplift) = -68 lbs [0 Net Uplift] V= 220 lbs V=284 lbs ASC /.10 W1ndEorceStandard 4 _ t RoofTop.lVlech_IIuit Wind Speed: 120 mph Exposure: B Height of Structure 201-0" assume Af<0.1 Bf::Force increase factor x=1.9 az: 23.24 psf kz: 0.70 Unit Weight 1,000 lbs Gust: 0.85 Ka: 0.90 Unit Height 41" Cf: 1.30 Kzt: 1.00 Unit Length 88" x: 1.9 Unit Width 54" Curb Height 14" WP: 48.8 psf P: 734 lbs-ASD T= 734 lbs *(14"+41"/2)/54" - 0.6* 1,000 lbs/2 = 169 lbs Net Uplift NORDLING Proj. No.: 17-156 STRUCTURALrEVo ROOF MECH UNITS ENGINEERS, LLC PAC TRUST 6775 SW 111th.Suite 200 Beaverton OR.97008 Date:JUN 2017 By:JEN Sheet No.: L3 Unit Report For 2ton Project: -Untitled1 Prepared By: 05/10/2017 06:28AM Unit Parameters Dimensions(ft.in.)&Weight(lb.)*** Unit Model. 48VL-C240403 Unit Length Unit Size• 24(2.0 Tons) Unit Width. 4'0.1875" Volts-Phase-Hertz. 230-1-602''7.75" Heating Type: Unit Heights 3'7.75" Gas * Weights and Dimensions are approximate.Weight does not include roof Duct Cfg• Vertical Supply/Vertical Return curbs,unit packaging,field installed accessories or factory 40,000 Btuh installed options. Approximate dimensions are provided primarily for Standard Unit shipping purposes.For exact dimensions and weights,refer to appropriate product data catalog. Total Operating Weight. 304 lb Warranty Information 1 year warranty on parts 5 year warranty on compressor 5 year warranty on heat exchanger No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description 1 l 48VL-C240403 Rooftop Unit Quantity Base Unit 2 Packaged Rooftop Builder 1.46 Page 4 of 43 Project: �Untitledl 6:28A 0 Certified Drawing for 2ton Prepared By; 05M 6:28M UNR ELCI910,L 01,11 07. 1.8,1T 11II08T I8YNN CII.VR30104111101 1,9 A4 s.[NrCN or 611701 TY II,NN /8410-!9 0.4t0.40/0“)30 296/631-7-30 ,,p1, Y 2 -+ 9-15'16 48417-64(90r010lG4073A 8001: ;38.4 13-314 1171 70-13416' 171.1 1-5118 ;AB 15-11,16 390.5 0 3 71-9/16--.. 9-1912;.,_. ,20312-1-ED 936 '60.0 IS-3/4 1165 2-1.0/76 571: s'- C752 41 1311,71 7353.61 48417-lY[3610601090313/5/6'0 000!735-140,1031730--60, 460-3-6D 349 158.4 31-3f I .5116 JAB 9 I106--T11" S-13+14 401.6 3-1116 .— - 4 1315 2Y13/163571.: s5•SAtl JBB.9 i6-5'8�Jit.3 181.91 I LrI1 I 40173.1E C0p011 4E 107. 15/X4 �I� X11 '1' 31. 2-3,4 14 1041231 43.1 i2.r me 01.0 91.E 41.4 103.+ SIJ 169.91 el NETWN J. 9022.7ci 30 7081034 50.1 20.9 ii,.1 30.5 tA0.8115.7 101,E 58.1 3A 716/256/+30 57.1[7).7 69.61 S.!ID4.11+7$477,7 55,4 { I O°IIOIAL 4 At7V0 4 1 I [lULl L I• '5-15,'14 C'""?‘ '""G I SPED i [724,p7 • � IOPEVIAO I A., fill qlN, r,,a, ISN.('l df'' 4•1,:11':W..V OP'i'lfd,IG, i 411 2171)000 con. , _ t 4 N'! 1 1.3.14 106 01 0.13MI)1FS'IV 7111.01 C[Rm11f16LE NM Y 7..'I I 7C7 OF UVIT MKS:,4111 I I IN SIDE 0�DTI! 14 1535.61 I 1 Citi oPY4'S1T0 11479 " 16SY'AI 307f0N OE MIT ELLE PANEL I/OI/2 471.71 36 1914.41 �' tau MUM%[9.WNAK'CY, JJ// 9074E14 Jars,imp F6131 SIDE 00000. 'NN] IACCOi COI. �G uYlr 1,x0 1 SApw0E0 0481*8[9,90,4[6 LorpY LIGE.. 42 Ci°66.81 TOP VIEW u70001 COIL war AA 31604(I)GOx04ER 0/L15 640 01904 a tDu.a G4o3AC0A 00414039, 1'09_°(9110 SI00 • .•.. 40. (1260.01 1117,4,4 0•'012811 Rat It'GI4I 9 AEU IC4YIII40•. E4N',KGIL 4.4[['.80 SIA[ DINES'11,41 mr:3 x 2' j6 1914.01 /000(61 fa110(0"EA11301401TS1 '. .' 17[IOW 0 l 4YIT 7TOP07010):CTS. .. .... .IA[1719.11 11 77 .. 023) 44011 3t 1108,110 11-'!s6 4.2/0- �- [70J,5) 146.71 I [1143.01 4-113 *0141x311 D0ST4.YCES:IE oorr I3 41ACE)1111 7336 12 1303,91 2141 1441, J 467111,iNM 448711 P[p!0x119117 NATE[II6)40DIN 04 ... [114.31 IINEASMINS IM AIIE IN Np. 1111111111 ' 111""'7 ,///11 CE551"'El I!iiiiiiIil 0- TliiiiiiH.HE hllDllhiiHiflhihi �..�.��. '�""'1""'! 7.149'I28.PCAEPA[Mf.i+ 15 !IIIIIIIIIIIIIfflhIUJ .A. FtT° U8'[22.21 6IA. 1DLE 1007001 EATAY� I I ¢it?u +• Iu '9.1s,u,3-sraESA4 Al—_/. 8I 1. 1 :356.)70203'13 614 7-318 �I9B� IZ-191'6 CONPrES50' ��l;rN_ r��' [166,1] 3371,41 P4YFI1111DLvNER Y ����� PAMrI 4-11/16 1` 31;6 J2-5l8 rIn.71 C4 61 2-5/ 1,7'104 11 D,r I 3-6116 021.per, 011,2,ocrt[T 33-1613 1-'3 GAS Div IB7.31 t..1 I1i/01111031,61[0 LEFT SDE VIEW `'u''01 01-013s,44, 7751�e1 IS144.11 1750+61 FROM VIEW ``3'07 RIGHT SIDE VIEW REAR VIEW BVL50631)L I _ 6 Packaged Rooftop Builder 1.46 Page 5 of 43 SUBMITTALMicraMetl 48VL A24-48VL A36,48VL B24-48VL B36,50VL A24-50VL A36,50VL Part Number: 824-50VL 8360 FORM NO.7843-1p I 4/3/2015 CRB-SDSML-14 Submitted To: Company: Job.Name: 2 TOS 10° Notes: .----- 21 9/16'•!,---- SGAA<Y Knockdown? Curbs Full Perimeter , • w C UStOr11 Heights Are Available. ,� �FT(j.,� ii 1. • • "Fully Insulated Perimeter Curbs Are Available And Designated With A"Cl:"Suffix. A ///�, • w TTolcl Dawn:Brackets Are Available For.Most Curbs. ,//' • Attach Ductwork Directly To Roof Curb,Flanges Of Duct `. Rest On Top Or Curb. • Any Posted Weight is Actual Weight,Not Shipping*Weight • All'Dividers&Supports If Present,.Are Flush With Top Of ? d3`16 Curb Unless Noted, �3i�„'O ' x Please Contact Factory For Pricing and Availability / FEATURES: 11” 1011"I • Ships Knockdown,Assembly Hardware Provided When f F;Ii 2.75" Needed. �' • • Deck Pans When Factory Provided,Are Factory Insulated. A • Constructed Of Galvanized Steel. • Gasketing Package Provided. —"" �".$7$ •• Full Perimeter Wood Nailer Provided, MlcroMeti Curb No. Carrier Curb No. A Weight J CRB-SDSML-08 8" 56 lbs bs • I 2" I`°lCRB-SDSML-11 CPRFCURB010A00 11" 63 lbs (IICRB-SDSML-14 CPRFCURB011A00 14" 70 lbs t!4 CRB-SDSML-18 18" 91 lbs CRB-SDSML-24 24" 108 lbs CU-2U THIS DOCUMENT IS THE PROPERTY OF MICROMETL CORPORATION AND IS DELIVERED UPON THE EXPRESS CONDITION THAT THE CONTENTS WILL NOT BE DISCLOSED OR USED WITHOUT MIROMETL'S WRITTEN CONSENT I MicroMetl Corporation... Indianapolis Indiana — 1-800-662-4822, Sparks Nevada — 1-800-884-4662, Longview Texas— 1-903-248-4800 Unit Report For 3 ton Project: -Untitfed1 Prepared By: 05/10/2017 06:28AM Unit Parameters Dimensions(ft.in.)&Weight(lb.)*** Unit Model- 48KCDA04A2A6-0A0A0 Unit Length Unit Size: 04(3 Tons) 3'10.75" Volts-Phase-Hertz. Unit Width. 3'10.75" 460-3-60 Unit Height: Heating Type. Gas g 2'9.375" Duct Cfg- Vertical Supply/Vertical Return "� Total Operating Weight 500 lb Low Heat *** Weights and Dimensions are approximate. Weight does not include unit packaging. Approximate dimensions are Single Stage Compressor Models provided primarily for shipping purposes.For exact dimensions and weights,refer to appropriate product data catalog. Lines and Filters Return Air Filter Type• Throwaway Return Air Filter Quantity. 2 Return Air Filter Size. 16 x 25 x 2 Unit Configuration Medium Static Option Belt Drive Al/Cu-Al/Cu Base Electromechanical Controls Standard Packaging Warranty Information 1-Year parts(std.) 5-Year compressor parts(std.) 10-Year heat exchanger-Aluminized(std.) No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description 48KCDA04A2A6-0A0A0 Rooftop Unit Quantity Base Unit 4 Medium Static Option Belt Drive None Packaged Rooftop Builder 1.46 Page 12 of 43 Project.-Untitled1 Certified Drawing for 3 ton Prepared By: 05/10/2017 06:28AM NOTES: S. DIMENSIONS APE IN INCHES DIMENSIONS UNITED P.O.eoA Dee If61r DOCYN[NT Ir THE IAOpfRTI OF CMRIEA COeP01AT10A IN f 1 AAE tN IN INCHES d. UNIT J N(1 PHASE) N(3 PRASE) TECHNOLOGIES e1RACSf[,Nf AM Ie ❑YE3EO at THE 000003!CONr1TIDN THAT TXF SLWN13010N Of 7RG[0A0111MS OA SOCSNENf7 2. CENTER OF GRAVITY 486C 04 33 3/8 II 7/8 14 7/8 -- CARRIER 17021 [OAPMAIION 7 MIfTCX COWtiAi.OP OAEO RI INOUT CARRIER WESEj/AXCF DIARE�X�RA00CT00E DO 18471 13711 (3771 3. DIRECTION OF AIR FLOW 48NC 05 33 3/4 If- 4 7/ 11 (48 CONNECTION SIZES HOLE- ANC 08 11 318 14 7/8 18 5/8 A 1 3/8' (331 DIA FIELD POWER SUPPLY HOLE [10511 13777 14727 B 2' (501 DIA POWER SUPPLY NNOCNOUT C 1 3/4'(611 DIA GAUGE ACCESS PLUG 33-3/8 0 7/8.1220 DIA FIELD CONTROL WIRING HOLE 08480 E 3/4'-14 NPT CONDENSATE DRAIN F 1!2'•11 NPT GAS CONNECTION ..... ... 32-1/1 ECONOMIZER N002 1 8 2 1/2• 1641 DIA POWER SUPPLY KNOCK-OUT FILTER ACCESS PANEL '_ 18181 (OPTIONAL) I8 S) COMP. 1406] (TOOL-LES - ACCESS . CONDENSER •PANEL I COIL ` THESE:REQUIRED CHART USE INDOOR COIL 1 - • CRBTNPN'RO01A01, 003A01 ACCESS PANEL _ I Ar I ^ THREADED WIRE REO'D HOLE _ CONDUIT SIZE USE SIZES(NAO.) I __ . 25-5/B 10-7/8 ♦ W I/2" ACC. 7/8"122,21 ‘4.))1 � Z )/2' 248 1/8" 122.2] ;MME�������M1 44 � C652] �� C2171RETURNYnJ1J'(001,003) POWER 1 I/8•[28.41 �I �p RETURN AIA e[71177 `\\ `=lAIR Z . (003) I/2•FPiBACK ANDLE 2-5/8— \\ I O OAS 1 3/16• [30.OY (671 '� fOR"TNRU-THE-BASEPAN' FACTORY OPTION, T-3 • '''', F.......62%� - FITTINGS FOA ONLY X,T, 6 Z ARE PROVIDED CURB E ALT.—1 WIDTH CONDENSATE 1T-314 . SELECT EITHER 3/4.OR 1/2' DRAIN OPENING FOR POWER, DEPENDING ON WIRE 0100 IN BASEPAN 14511 10011 PpOVI0E5 3/4'FPT THOU CURB 18-1/8 Jz SUPPLY 26.1/229-3/1 AIR [4591AIR [673] 174118 SUPPLY �� FLANGE 8 FITTING. 16.1/8 1461!4 121214 r^ ', I [1117 13637 [972] SEE TNRU THE BASE CHART 6•/d I I I I 1._ ,j J1, , HOOD — 12-1/0 3.3/8 • 1HLUE 13071 7 -I 0851 ..___K [7387 -[7001 TOP 14101 4-5/8 11181 I _IF ELECTRICAL - _ [265)2 1-1/4 I _` DISCONNECT I. „ __� 1321 CONDENSER i= ii� DATION _ COIL -.A CONTROL ADX T-'I-8• ACCESS PANEL INDOOR BLOWER-G ACCESS E sm. �=_ �, CONDEDRAIN ILTER FACTORY =--L _0. _INSTALLED =._ 11.1/2 OPTIONAL ....--,=-,--. ..- 11-3/18100L_- I� I6-3/A • [6381 ii OUTSIDE CONVENIENCE jiw [4911 INSTALLEDT =-'=-1-'----- --_____---=—=- 12881 _— I 14271 RETURN AIR II OUTLET I�-= = = F HANDLE 11-3/8 SUPPLY AIR AIA ___ I—ff.,- DISCONNECT — 21-1/4 _.. ••_� [1887 I: I I F [1681 • '.• [539] 3-3A ��o� 'c7.: : o0 11 si �'�'. 1951 48.3/4 HANDLE !`� � 0.3/8 11187] 30-1/S [213] --fi-S18 T [1647 (1891 (1717 [152] ir p� 74-3/8 26-7/8--- V` (18881 16821 31-1/4 BAROMETRIC LEFT [7937 RELIEF FRONT AIA SUPPLr *RETURN R IGNr AIR SHEET ONTO 1000800600 48KC 04-06 SINGLE ZONE ELECTRICAL FY I SF2 09-16-14 - COOLING WITH GAS HEAT 48KC000281 _ li Packaged Rooftop Builder 1.46 Page 13 of 43 Project: -Untitledl Prepared By: Certified Drawing for 3 ton 05/10/2017 06:28AM STD.UNIT CORNER CORNER CORNER CORNEA UNITED P.O.ION aw TNI!OOC1N[M II INC 1AwwTT OR CMAIER CORIOAAT(W UNIT WEIGHT WEIGHT(A) WEIGHT(B) WEIGHT IC) WEIGHT(D) C.G. HEIGHT TECHNOLOGIES SIRAOW[.RT ew IA NEITYLAfO tlIw TXE EIIRfNS 000N)TIOA TART TNF ill Or IRENE DAMNS OR N000NENOS CARRIER TNRZ1 00X0140$WILL NOT AE UINCLOSED OA ONES TITOOOT WARIER wll XW CWSTITIE AAT IERELIXA10E w ( '� T L490 222 120 54 111 50 125 56 135 61 35 3/4(0087 24 3/4(6281 18 7/8(4791 BS. KG. LBS,1 KG. L88, KG, LBS. KG. L83. KG. K IEwlaAtloN'B XACTTCN COXNEN7. ACC[ITAMC[OE CONTAMT. 48MC 05 544 246 130 58 126 57 ' 142 64 146 66 36 3/4 I933I 24 3/4 16281 18 7/8(4791 '�✓' 488C 06 597 270 141 I 64 156 70 '158 I 71 142 6/ 39 1/8(9931 J 23 1/2015973 20 1/82(5111 FOR SOTNERA ROPT ONS WHAS ACCESSONIEd REFER TO THE PRODU TU TO CATALOG. CORNER A CORNER B 0 Y ;I�.,A11K1% 'r CORNER D I R ' CORNER C TOP 1 _ g . • - z * i=I FRONT SHEET BATE AU/ERCEAEe 2012 09-16-14 48KC 04-06 SINGLE ZONE ELECTRICAL w4 COOLING WITH GAS HEAT 48KC000281 _ Packaged Rooftop Builder 1.46 Page 14 of 43 Mi�roM i U B M I T TA 1 5OTCG)A04-5OTCQ A070 Part Number: FORM NO, 1174-1D 7/9/2013 0537-014A-00010 Submitted To: Company: Job Name: 3 si‘ rom, Nates Openlll0 for thn.r J the bottom electrical 1 3/4"Alt.drain hole I�r�nc�lzcllv�unlltr'bS connections Full Perimeter Blocked top 3 1 1 G' corners NOTES: Re�Grh Custom Heights Are Available. arr ''► • '"Fully Insulated PerimCurbs Are Available And 201/411 Designated With A"C["Suffix. 1d * " hold DWI]..Brackets Are Available For IV:ost Curbs. Supply air • Attach Ductwork,Directly RI;Roof Curb.:Flanges Of Duct Rest On Top Of Curb. 1 3/4"—mil mi` 67 3/ti" • Any Posted Weight Is Actual Weight,Not Shipping Weight 37 3/16" — .I.. '''Please Contact Factory For Pricing nnrl,lrailabililP FEATURES: A • Ships.Knockdown,Assembly HardwareProvidedWhenCRoss SEC'i-ION Needed. Or-CURB • Dock.NHS Whet Factory Provided,Arc Factory Insulated. 2' • Constructed Of Galvanized Steel. • Claslcet'ing Package:Provided. • Full Perimeter WooclNailc:r Provided. 0537 Series Roofcurb Specifications(in inches) MicroMetl Part No. Carrier Part No. A Weight 0537-008A-00010 8" 71 lbs 0537-011A-00010 11" 82 lbs 0537-014A-00010 CRRFCURBOOIAO2 14" 94 lbs 0537-018A-00010 18" THIS DOCUMENT IS THE PROPERTY OF MICROMETL CORPORATION AND IS DELIVERED UPON THE EXPRESS CONDITION THAT THE CONTENTS A 00010 CRRI CURB002A02 24" 131 lbs IVIICPOIVietl Corporation... Indianapolis Indiana— 1-800-602- WILL NOT RE DISCLOSED OR USED WITHOUT MIROMETL'S WRITTEN CONSENT 4822, Sparks Nevada — 1-800-884-4662, Longview Texas — 1-903-248-4800 Unit Report For 5 ton Project: -Untitledi Prepared By: 05/10/2017 06:28AM Unit Parameters Dimensions(ft.in.)&Weight(lb.)*** Unit Model- 48KCDA06A2A6-0A0A0 Unit Length: Unit Size* 06(5 Tons) 3'10.75" Volts-Phase-Hertz* Unit Width:. 3'10.75" 460-3-60 Unit Height Heating Type: Gas 3'5.375" Duct Cfg:. Vertical Supply/Vertical Return *'* Total Operating Weight 607 lb Low Heat **' Weights and Dimensions are approximate. Weight does not include unit packaging. Approximate dimensions are Single Stage Compressor Models provided primarily for shipping purposes.For exact dimensions and weights,refer to appropriate product data catalog. Lines and Filters Return Air Filter Type Throwaway Return Air Filter Quantity- 4 Return Air Filter Size* 16 x 16 x 2 Unit Configuration Medium Static Option Belt Drive Al/Cu-Al/Cu Base Electromechanical Controls Standard Packaging Warranty Information 1-Year parts(std.) 5-Year compressor parts(std.) 10-Year heat exchanger-Aluminized(std.) No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description 48KCDA06A2A6-0A0A0 Rooftop Unit Quantity Base Unit 3 Medium Static Option Belt Drive None Packaged Rooftop Builder 1.46 Page 22 of 43 E....,8 0 Certified Drawing for 5 ton Project: -Untitled! Prepared By: 056:28 17 06:28AM NOTES: 1. DIMENSIONS AAE IRM INCHES DIMENSIONS UNITED A.D.em 4*33 14(3 DDCDN[NT I2 TXE IAONEAtt OT CAIIAIEA COROAATION IN[ I AAE IN N[LLINETEIiS. UNIT _ J K I1 PHASE) K(3 PHASE) TECRNOL0GIES 31AAw1E.Nr ANG I!GtE 001605 UNd TIE ENNAE!!OONDITIOI TXAT THE NMNI!8I5N or METE OAANII!OH MEM 33 3/8 11 1/8 (4 118 CARRIER 11221 Ifa°NAeTOAnttA�ION i RAMP P OA WEO"NT CAlAiEI WC!NITACICENPUN[[OiAACOXiircT E OA 2.© CENTER OF GRAVITY 480C 04 18111 [3771 13771 3. DIRECTION OF AIR FLOW MC 05 I8/7/18 IL 377 1I 5/1472] CONNECTION SIZES 4511°OB 41 3!6 11431713 4 7/5 11147/T 5 5!8 A 13/8• [35]DIA FIELD POWER SUPPLY HOLE [10511 !3771 (4721 8 2' 1501 DIA POWER SUPPLY KNOCKOUT C 1 3/4' 1511 DIA GAUGE ACCESS PLUG 33-3/S D 1/5" 1221 DIA FIELD CONTROL WIRING ROLE 08487 E 3/4'-14 NPT CONDENSATE DRAIN " F +/2'-14 NPT OAS CONNECTION __ 32-1/4 • 1 ECONOMIZER HOOD G 2 1!2'1817 DIA POWER SUPPLY KNOCK-OUT FILTER ACCESS PANEL i—'" 15151 (OPTIONAL) 16 (TOOL-LESS) COMP. !4061 • ACCESS I CONDENSER •PANEL THESE HOLES A OUIRED SFORAI USE INDOOR COIL 4- . —- CRBTNPWAOOtAOf, 003401 ACCESS PANEL I I !. II , THREADED WIRE REO'D ROLE THRU-THE-8ASE CHART CONDUIT SIZE USE SIZES(MAX.) 11 i'` \� 25.5/6 W (/2" ACC. 7/8"122.21 t;' ,-6. i... /%/ \�`1 MI? 117118 Z I lz' 21V 7/6"[22.2] ��11�11�pliJ'� 14 1 ®� RETURN AIR_'� RETURN T A 9/A" 1001,0031 POWER 1 i/8" [25.41 [11177 �A_ I ,, AIR Z+• (003)1/2'FPT GAS 1 3/16' 130.07 BACK ANDLE 266/8- ��� �� t FOR'TNAU-THE-BASEPAN'FACTORY OPTION, (6 T1 TYPE FITTINGS FOR ONLY N,T, b Z AAE PROVIDED CORN I N'W CONDENSATE I SELECT EITHER J!4.OR 1/2• WIDTH N DRAIN OPENING li-3M y " FOR POWER, DEPENDING ON WIRE SIZE 18-1/B 1 +;2 IN BASEPAN St4511 UPPLY 28.1/2 29-318 •+ 1001)PROVIDES 3/1'FPT THOU CURB [/541 I -I I AIR [6731 I7/T1 SUPPLY FLANGE I FITTING. 16-I/6 14-1/4 (2.1/4 I I AIR 14+11 13631 13121 SEE TARS THE -7 ' 1 BASE.CHART •• III 6- • [157 - }iIf 12-116 �^3-318 225 636] •'•/ LUE 13077 [551 Ilk K [fool TOP HOOD u7oi2 -4.5/8 [1181 10.1/2 r LECTRICAL [2857 1-114 iiTI jDOSCONNECT P . [327 CONDENSER �I� LOCATION I �COIL CONTROL 000 INDOOR BLOWER rOPTIONAL ACCESS PANEL ACCESS E STD. I ILTER CONDENSATE —„,.. CONVEA[ENEE 0. (4941 ACTORY I!� I RETURN_ I 191!2 OPTIONAL ® [6381FACTORY 18.3/4 OUTSIDE OUTLET = INSTALLED F HANDLE Il-S/N I SUPPLYIAIR AIR AI�DISCONNECT I2B97 _ == — — � �N 8.5/8 =iR s BR�= .� 8 [1881 .I`j'" • - • • Ii..___ --_, L-__-� [53914 3.3/1 f ��� J �. cop- 8-1/8 •+�'•������ HANDLE " (1001 — i�� [957 46-3/4 �'�� B-3!B 16.2/1 30-1/8-- (0131 --6.518 7 6 `� 17641 11687 11771 mu ir 74-3/5 26-718 11888] (8821 31-i/1--- BAROMETRIC LEFT (793] RELIEFI FRONT SUPPLY AIR 1 II RETURN RIGHT AIA ISHEET DATE 2UPUSCF*E! I 48KC 04-06 SINGLE ZONE ELECTRICAL I of z 109-16-14 I 48K0000281 I la COOLING WITH GAS HEAT le Packaged Rooftop Builder 1.46 Page 23 of 43 IProject: -Untitledi Prepared By: Certified Drawing for 5 ton 05/10/2017 06:28AM STD. UNIT CORNER CORNER CORNER CORNER UNITED A.D.AOA ole rxls 801OG 1T CC TMC 110100 1 00 CARRIER CORPORATION UNIT WEIGHT WEIGHT(AI WEIGHT(8) WEIGHT IC) WEIONT ID) C.O. HEIGHT i,��[//�,y TECHNOLOGIES OTAACOSE.N1 IFMD I AEUYEAED 0Mx 100 05AC0A COUCll0I 1AAr TME Ii00N111111 CE"En OAAIANO'0A 00111(ATE !I 'AI[/ CARRIER 1sEE1 1OAP0�A,Tt, S:1 TT[N 10X!211[0"""I m"7"1"1A S "AcTI C I IIN71KiA""01 35 0081 24 3/4 16281 18 7/8(4791 48KC 05 544 A. 181E D6 5N7 1210 III 54 158 I 50 15842 641 142 l 64 66 336 314 19331 24 3/4 0 1/8I[9931 23 1/2Y[5671 20 1/8I[5111 /"- POR OTHER OPTIONS AND ACCESOIRIES.O REFER TO T EN PRODOCT OAU CATALOG. CORNER A CORNER B 0 I i 1 if;'Z ',\ l '�t6, r 4110)11) .'h 0 CORNER D 1 ' CORNER C TOP • 7 I i p-!-1===' ! . z I—i Oo Ell. s . 1 I FRONT SHEET DATE MERCEDES Q 2DP2 09-16-14 480C 04-06 SINGLE ZONE ELECTRICAL DES COOLING WITH GAS HEAT 48KC000281 ti Packaged Rooftop Builder 1.46 Page 24 of 43 SUBMITTALMicroMetl 50TCQ A04-50TCQ A070 Part Number: FORM NO. 1174-10 7/9/2013 0537-014A-00010 Submitted To: Company: Job Name: 3 5 (OTOI*J Notes / 1 Opening for thru the bottom electrical 1 3/4"Alt.drain hole Knockdown Curbs connections Full Perimeter cGlodced top 3 14.1s?.:-...* '1� 6" cornors .44. 4 N.,,,,,N • "'Custom Heights Are Available. �/� • �0(4rrrir `ti g. '"Polly insulated Perimeter C't bs.Are Available And 20 1/4" • \ %\,,,,,,,„, Designated With A"Ci"Suffix, • 1 d 71U° ,, { • "Hold Down Supply air yy++.. A • Brackets Are A s Available For Most Curbs. • Attach Ductwork Directly TO Roof Curb.Flanges(7f Duct �`� Rest On Top Or Ctu•b. 7\ 1 3/4•,—�I I • Any Posted Weight.1s Actual�tr�aighl,Not Shippin,r,.Weight 37 3/16" t.. '<Please C'rurlrrc't&rcturl'For Pricing and Availability FEATURES: A • Ships Knockdown,Assembly hardware Provided When CROSS SECTION Needed. 4I I Oi=CURaS • Decic Pans When Factory Provided,Are.hactory:fnsulafed. I 2" ""' • Constructed Of Galvanized Steel. • • C;eslcefing Package Provided. • full Perimeter Wood Nailer Provided. 0537 Series Raofcurb Specifications(In inches) • MicroMetl Part No. Carrier Part No. A Weight 0537-008A-00010 8" 71 lbs • 0537-011A-00010 11" 82 lbs 0537-014A-00010 . CRRFCUR6001A02 14" 94 lbs 0537-018A-00010 18" CIMD �+ THIS DOCUMENT IS THE PROPERTY OF MICROMETL CORPORATION AND IS DELIVERED UPON THE EXPRESS CONDITION THAT THE C�ON7 024A-00010 CRRI=CURD002A02 24" 131 lbs �A MicroMetl Corporation... Indianapolis Indiana— 1-800-662-4822 S TS WILL NOT BE DISCLOSED OR USED WITHOUT MIROMETL'S WRITTEN CONSENT parks Nevada — i-800-884-4662, Longview Texas — 1-903-248-4800 SUBMITTAL . , r ,: ,,, '",MICroMeti 50TCQ A04-50TCQ A070 Part Number: FORM NO. 9174-9 D I 7/9/2013 0537-014A-00010 Submitted To: Company: Job Name: 3 5 ATOM Notes / i " Opening for thru KKnockdown the bottom electrical 1 3/4"Alt.drain hole no down Curbs connections (III0°. ` Blocked top Full Perimeter � /,/" .` 3 1 16� corners NOTES: dir /` * '"C`ustatu Ilctghls Are Available. '/ • *Fully Insulated Perimeter Curbs Are Available And 201/4(.....-2" / ' Designated With A"CI"Suffix. Supply air s • w Hold Down.Brackets Are Available For Most Curbs. * Attach Ductwork Directly 7i7 Roof Curb.Flanges Ol.Duct 67 3/8" Rest On Top U1 Curb. 1 3/4"�I �-- r « Any:Hosted Weight Is Actual Weight,Not Shipping Weight --t-7 I I 37 /16" 1., '°Please G i»rirrct Foamy For Pricing and Availability AFEATU.RES: • • Ships Knockdown,Assembly hardware Provided When �� ORC)SS SECTION Needed. l C)!=CURs 10.1• Deck Pans: When Factory Provided,Are Factory Insulated. 2" I r • Constructed Of Galvanized Steel. • Gasketing Package Provided. • Full Perimeter Wood Nailer Provided. 0537 Series Roofcurb Specifications(in inches) MicroMeti Part No. Carrier Part No. A Weight 0537-008A-00010 8" 71 lbs 0537-011A-00010 11" 82 lbs 0537-014A-00010 CRRFCUR6001A02 14" 94 lbs - 0537-018A-00010 18" 0537-024A-00010 CRRFCURB002A02 24" 131 lbs CU-Ip THIS DOCUMENT IS THE PROPERTY OF MICROMETL CORPORATION AND IS DELIVERED UPON THE EXPRESS CONDITION THAT THE CONTENTS WILL NOT BE DISCLOSED OR USED WITHOUT MIROMETL'S WRITTEN CONSENT MicroMetl Corporation... Indianapolis Indiana— 1-800-662-4822, Sparks Nevada — 1-800-884-4662, Longview Texas1-903-248-4800— • Unit Report For 6 ton Project: -Untitled1 Prepared By: 05/10/2017 06:28AM Unit Parameters Dimensions(ft.in.)&Weight(lb.)*** Unit Model* 48TCDA07A2A6-0A0A0 Unit Length' Unit Size• 07(6 Tons) Unit Width 6'2.378" Volts-Phase-Hertz. 460-3-60 3'8" Heating Type: Unit Height: 3'5.375" Gas "` Total Operating Weight' 662 lb Duct Cfg• Vertical Supply/Vertical Return Low Heat "` Weights and Dimensions are approximate. Weight does Round Tube Plate Fin Coils not include unit packaging. Approximate dimensions are provided primarily for shipping purposes.For exact dimensions and weights,refer to appropriate product data catalog. Lines and Filters Gas Line Size: 1/2 Condensate Drain Line Size: 3/4 Return Air Filter Type• Throwaway Return Air Filter Quantity:_ 4 Return Air Filter Size: 16 x 16 x 2 Unit Configuration Medium Static Option (Belt Drive) Al/Cu-Al/Cu Base Electromechanical Controls Standard Packaging Warranty Information 1-Year parts(std.) 5-Year compressor parts(std.) 10-Year heat exchanger-Aluminized(std.) No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description 48TCDA07A2A6-0A0A0 Rooftop Unit Quantity Base Unit 1 Medium Static Option(Belt Drive) None None Packaged Rooftop Builder 1.46 Page 32 of 43 e« Certified Drawing for 6 ton Project: -Untitledl Prepared By: 05/10/2017 06:28AM +OIE$. IINiT Carier,. N 0^ "T 1 5 Ca 074un SuL T5uA1 x X iL DNAEN NRLENINNIN01(t0d d[2A2ll R"+31a DRAWERSREPRESENTS PRODUCT LUILT ATT_11 01/01/2017 0...+ rr ' £'iilk '"" n''' 1 LENTEN pF GRAFI') 4.110-0: 3 4a 7re (START[NC 'WITH SERIAL NUI+BEH 011'1•, ; SEE D'1AIL "E" 21,4W 111,1 ;. o-R(C-ION OF AIR FLOW 4Ak4.0E )" '!0 IA NU 38-.4rA :04100-InN 411E4 [9A 7] fA XRI 7 LLD [Ak8 ADI'P.Y NULL [d Y/ A 3/U. L'ii.1 11 F. P• AJ TC M01 "� +e 10 7!8 _ R 2' 1503 DIA 20vil LFPLY RIOCNOUT + - .'11G,t.01.1 vIEW pFAHN 0111)55 !ND ANILE I'D''' [J7;1 [8171N • ECONOAIIEP.FO:D ' f C 4 3)4' (917 311 loch ACCESS 5123 ,G 0 1,2' 1221 DIk FIELD EWM.415112 {OLE IP ' [.S'] E d/4'-14 NPI :012134AL 05015' 5-S/3 RE LANA 6921IId r '.2'-I2 OPT 101 POu1FC71CM •.1 g 2 1+7"I647 DIA POWER E001.1 000.001 rrr,i � rlsu THE 000:CoUP- /• , "�' 1p-718 CFTNAN TNISE JOLEL REOJINEO FOA USE • f1� � t1 ' fl�i••'� LGJ'!J AI{ C7NiMPI F00"101,7O3A 01 N�,����'f iH11I-SI 'NNE SIZES NOPE 010. GI C010UI-SIiE USE SIZES LDOL W11-I'A ,�� 5 ✓� - Pn ' „ 4 1 W i!)' 1135' !it!!(22-P1 [1120 J1 C { E 4LT.J . 1 I x ,/2' 24V '+F" 122 11 /• - ( C0kl1FN'SATF -`\ ( • I [TI N I�� Y 1!1' POYEO 1•t+a'028.83 • • OEA IA UFESINN ��\ /// 1T-3!4 !1 +00347S) 177"h'I GAS I-.+8•L2N EJ / r,c �C ]A piSEPAN 30113 _ 5 I :UPPLY 1 OR.,,r;7HEBASEPIN''ACTORI CPTICN. '4-177 � } .a l A[9 Pfi-4/A .L'I'LY fIT7IAGi '0R OYLY%,Y, 8 Z API PROP:p[7 'Ay! IZ•t/Z 71-132 1 - + � \ . 1D791 AIN 4 500.0(7)000P1OES 3/A"FIT TNOU CAR :.110: ,,_,, ' I TEE-,,711 TIE \_.' FLANGE I FETIILO. 11 ( RASE MUT 4 '0-718- . ,,".A i':i 911 / I241 Cfi037 - ti;i1 3-131 �• I ,1 \ (1587 — t/_•re CAR] n Ott --FCWE OFF bF7Ail T--�/ _•�•—• C4n1] +----E, .. I MOW SNFTT 5 {.-�7%75 50041 �— 16.5+8�-J ^-JR.+-:10 TOP [4721 I:,e7 �r(L(C'RICl.L C0o0iDIAN [t69i2 i'11CUNNLCI D7A_H I 1-112 LOCA-ION I• I 13,01 CON]CN:ER "'�'���s COIL - r ' A'R'C CONTROL BOA .7--—� -T FEIL(E7 AM ES PANEL ' VI•I IONAL INDDOE OLCREN 10-3/4 5.5+8/ 000USY~� ..'r AL-CL�Y?AUL 10211 l' 18- INSTALLED {{I �� S.rPLr ALN IE•pI (OEVNIEN"E mss,I if ) i J .__.. .. ` •i AIR =�OUTLET u I ariIlN4L-- FN� i, - • / f 13-/2 INSr410tU /r III /.—HAV71: • `1-910 �, 1'{ t /EI-I/4 I'. II;;' DI9CDAXE:T J ,l 12851 •x 1 • �t i .- 0-358 07877 'I `• 1.�I / q. / C:993 AILS:DE 9.9/< 9 1 ,_,CIO ..,«.+..I I Oa.: (157 / LD31 4A-3/5 ,. HINOL(� EltiHl E-uN 38.18 - (2141 (1331 sits ['7'] 0121 171E: !G-2+8 LEFT 74-1/0 -AA)' 14 (1005] ('-03' 01 C'633 5111015 FRONT 7('PLH FU 470 ill, 11,RET1RN RIGHT AIH IT:CL/AIIFICATI0:1 1 SHEETTACE o 'ic[UES AETC )4 07 SINCLC ZONE ILCCTRICA_ asraso.s9s I Hk U.S. ECCN:NSR 17F: I 8-24-101> I 3-OS-FO'S. I LOLLING KITH GAN 7E.AT I Packaged Rooftop Builder 1.46 Page 33 of 43 • Certified Drawing for 6 ton Project: -Untitled1 Prepared By: 05/10/2017 06:28AM ..R-NI" lionY(9lAy FAt DRI eM C%m.TTId l,..,...m HR a.R...o?....- :10)15, uNIT " 1.U1EAH NMLIEI "."544TP.04 32:18 18 348 ;,--- 0n :r,TOIRP , R....AORr Oonlros K404EtrrzCThiglrRI O141 I4i] 7 ei CENTER 1F 118.1417T 44TLtw: 83 S/a 14 Ire DRAt9IRc REPRESENTS PRDGU:- BUILT BEFORE cr.;D1;2917 t34n ISJil SCC )CTA=L NDN :111511t-tt11 S7/CK s.�U-IIIC 105 UI A18.4LON 4dTT..nT 17(!4171] 14 //V A t 3r8'COIN)A F:E1.11 PUAE9 KOUT HOLE ,1, 447{.,DI d0 318 to 778 5 2' 1501 DIA"OVER 1.9PLY KhOCKODT 1' L-_1 . ALL VIEW 06581 USI11v IRK.NGLF 115811 IJ!'1 F. :314' Fill 711 6956F 411505 PI lls r 13 3/3 .I n Yra' 1221 1)I5 FULD CONTPOL 5I79I13 101E 18481 F 3„P-t8 NNTTO,VSTIJLA F 71515 Y :42-14 Ill Ai CSIRILCIIUN - ' I 7'---1. 4 2 112" (64]NA P0015 NLPPLI KAO:KOUT 32-14 (CDUONI/CN MC(818] (77171oK9L: 16 FILFEI 4CfE39 PANEL [4067 1/091.•11:341 orm. 25-518 A:L•S5 :11VDchFEF 1021 TNRU-TNE•BESF 01551" •PATEL • :OIL DCTuss s(A 'NESE HOLD AEOJI, 5 FDP, D]E GIUnaR f:DILq i •� �. J . . OPUTN114AD01A05, 801409 1FCT.N PIHFI • "7.------- � -'� .fiI 4 AIME 411 PEr.•n Nr,Lf ,.:,... i.,-,\N.-�., C COVU7IF FS;E USE 5/aI 95,1] O11* �._-_.� \ 'I.~^f• ID-T/8 P Ir.. 7154' 1/8� 977 ] J(� A Ile• 2J'1 1!e' 122.13 _ - y 44 I'(IINY 1�{it • C79T] R Y • 1154' '0FEI 1 i/8:C18.01 111577 \��`� �,� n A-A 114 :063/017 A/ FF (TAS 9 lir E75.61 '!u �I '' I?'A I 2" T BACK (TT] % 1 �—'T kO""IHI:I•IHk•8trAT 1.5!:10"2 OII Tk, -YP � �'� '!.Li.— \ FIRIVG- FOt UIILi A,1. 6]AAE PI0'II PEC CUP,O Z--� \ C0NUATI `\ / MITI, ORAih•751NIN1 / / I 'oo ,CIT11-R 3•P flr \ IM id:(PAI • (A3.1�4 Ci417A ly OPOISF 10R(i', DCDLNCI4O4wIHI SI:6 1 111F SUPpU 2b ito 44 'MD',Yµ7gIl: 144•Irl INIII LUN9. 10 118 I I i r I / \\ AI9 [8737 SICILY FLANGE A FITTING. USD7, .7115 -4-t;4 to v9 , \ ` 1071 (4691 [it 21 y 1 5E-;.TBiTIIE—/ f-1:4 # i I V, E[HAAT^. ./ ,ii!j; II }I 1 \ R ' / t's e.' -F"."'. \ I .. 12.915 1 18571 S'F IIFTA FI B- a 13071 4 SHEET 5 AI 23 mai HG C 115-112 <-519 IB.381 �)" 14701 C+-7 b1 E)T1,-- CCWDESSArE - 7C 1/2 'I •-ELECTRIGL - - 0RA(h 12959 1-114 ./OTSC9N9Ff.T 1327 C0h'D(VSCR I I LG:AFI9N 1 �128 IH—B:11 _B,1 LCNiNCI Pt • II r05 Jr7 Af:CE55 P.th(L • INDOOR 5-0411 ACCESS PANEL 25-178 OPTIONAL—,—.'__ 16-3/4 1 I[6315.2' I 7r:L-21 . iii 1r [42 TI RAllt ! TAC70RY IA5IALLEb GUPPL"Al:: • 15 _ CONVENIENCE I J '� i• OvT.07»el1 ._,_ 6___-_.---- J m,n R I I �`011 '�I�Yp1F4Y. ,,rHAN+4 F n3rK 1 1 i/' i. ®• �::I UK.] 1767: �, �` I'551 ----- �G Q '-I;n co :3181 9-314 (057 4A'.VDI F—/ �RRVRRRRRR�RR��RRR��VR.R.� 46)14 8.318 411811 30-415 [71:1 C7647 41591 [t 1!7 /1}21 11. 74-34 46.1!15 140051 (6121 EARORKTRIc '-'/" RELIEF L1.1 RPLv Ir437 FLOR FRONT AI4 #AINURN RIGHT t^� I ITt SL,5(ITICRTI04 SNEIT 1411 60PECtuts 4171 94-07 3:5[1511 00711 CLECTRICA- I I 1,15t "" ! it S F'CN•NSR I 7 IFF I 0-94-2611 19-V9-i/-S I CJCL100 NITH C94 1191 487450[993 H .1 Packaged Rooftop Builder 1.46 Page 34 of 43 Certified Drawing for 6 ton Project: -Untitfedi Prepared By: 05/10/2017 06:2818 �.,R4 ld 13,'qCf YE y CN IIOv[R ((CAN!E! AT(X 211. I CORNS CCH 1 1 ''0111 1 11.41 I �W>'Ii61�1X3 7!CELIY�R4 :[C lA[E)�NF33 CD Ii"ICT X(T t! (t tv u[o1 a!T1[(t;RAYIRc[ev MryR1Xn POT* 3k.GNl MUM SAI WLILHI {tll WLLGXI {Ci v111.41 ID} Cl.. 3E76FT . riiT rora int6Dt XttR47[A I i, �gl$7[TTCrArt IERfORAAICCO> 63S. G6 L85, 16. LRS. N6. LAS. CO. 18f, 06 1 0 �Ar.+nrrR4, C01i0T6i:OX'SIY.If7U[OXIEX ! nNt[n mer.ert. 46TCDCC4 480 213 101 45 117 03 139 630 2 06T[0e95 513 $3N122 55 31 [.91125[6151 16 i!E C45b7 i21 SA 125 0? 111 0, _138 01 0; [4401 74 16.101 17 19171 40TCDe00 340 254 126 57 336 02 155 74 Ill DL 30 [9131 E4 18101 1. if,04307 —'•--• •---._-.---._--�_-_•—.._ 45TCDV01 052 29i 151 68 188 76 110 07 [51 71 34 14511 23 15081 23 II5 [5517 -.—._--_--—'-----"—'---- 3tCK •3"AI_DARD eHIi 860083 IS WITH LOW Ohl 4E17 110 WITOOuT fA71(40[Nd. I YI_TH EC3$O CZER �,trk an OTN=O OPT:DN£d6D ACCESCOAIES, REFER 7C THE P[0305T OIT4 CAlALOC. t,: 'i2 �"`�� - - - - — -„' RACY :3 : A WITHOUT �_�_al A ECC'27NI2C(1 -5039 �\ Ernn2NMD CORNER A ..1_____,, i� CORNER B 0 a — h O lp giiiiiit) RIGHT —^IJNI _ I I LEFT . j tuinEH u I. I u { E CORNEA C i 7•SIA 3311 FRONT TOP 11. 1 111 2 1 �. 60TE5: O I, 009 A_L X;V:NPM CLEARAM1(E3 LPG AL cools ON JIt NI36I.TI049 NT PNEYAIL, Cl()(') '–'2-1 r • 0C4' i gR410E CLSARAPEE SERSKEWITk OPERATING SURFACE C@8[ICTNE R 118 3 NORCOPO[CTNE BARBER CLEARANCE F'ON FRONT 46 [1219m] 36 E014mn] 18 (48?m: LEFT 48 41219rrnj 4? L10610R61 18 1431015. BACK 48 (121 Ami,] 42 [1067,01 18 [Wm: RACK Yf/HCK11I lb 1914nmJ 30 L914mni 18 1403m. f♦ ROW 36 (914001 36 C3I4mn1 18 14570m: TOP 72 [1629RnJ 7? [1849rtmd 72 0628003 (4'y I .3 IT;.[LSSIUICIT(04 MEET offfO SSPECCIDE5 I I 401 t) 4ETC 96-07 6•?I OLE ZONE 1LECTRIC A. 4OTd56E9'13 II S F'f.N•N'R Di° ) 8-74-501; I I-11-20'5. I (061.166 urn 545 1E41 H 11 Packaged Rooftop Builder 1.46 Page 35 of 43 SUBMITTALMicroMetl 50TCQ A04-50TCQ A070 Part Number: FORM NO. 1174-1 D 7/9/2013 0537-014A-00010 Submitted To: Company: Job Name: 3 5 14 TOM Notes Opening for thru .the bottom electrical 1 3/4"Alt.drain hole .Knockdown Curbs connections • Full PerimeterIIIIIIBlocked top 3 116 corners l.. ` 1 8/8" NOTES: \��rr �e/Uri !% • '''Custom Heights Are:Available. vir * w Fully Insulated'Perimeter Clubs Are Awl liable And 201/ " o. ,, \ Designated With"CI"Suffix. Supply air MM * '"Bald Down Brackets Are Available:For Most Curbs. • Attach Ductwork Directly 1"o Roof Curb.Flanges Or Duet ~67 3/8" Refit On"Cola Of Curb. 1 3/4"---4.1 -+w-- 37 3/16" • • Any Posted Wej ilii is Actual Weight,Not Shipping Weight I • 11 r Tlcuse Contactt!irclora'For Pricing'«nri.<11 ai!«bililr FEATURES: A • Ships Knockdown,Assembly a•Iardwure Provided When L CROSS SECTION Needed. Or CURB • Deck aims When Factory � 2" klif Provided,Are:Factory • Constructed OfCialvtlnietl Steel. • Gasketinp Package Provided. • Full Perimeter Wood Nailer Provider(. _. 0537 Series Roofcurb Specifications(In inches) MicroMetl Part No. Carrier Part No. A Weight • 0537-008A-00010 8" 71 lbs 0537-011A-00010 11" 82 lbs ` 0537-014A-00010 CRRFCURB001A02 14" 94 lbs • 0537-018A-00010 18" ciNIn 0537-024A-00010 CRRFCURB002A02 24" 131 lbs �( THIS DOCUMENT IS THE PROPERTY OF MICROMETL COR PORATION AND IS DELIVERED UPON THE EXPRESS CONDITION THAT THE CONTENTS WILL NOT BE DISCLOSED OR USED WITHOUT MIROMETL'S WRITTEN CONSENT IC MicroMetl Corporation... Indianapolis Indiana — 1-800-662-4822, Sparks - _ p Nevada — 'I 800-884 4662, Longview Texas— 1-903-248-4800 Op UNIT' STD, UN T DLIRAELADE ECONON1sEFQ ECONON1 SRO 48111004-014 al 0) 1 0 AIONT EDI:3N wE IGHT wEi6HT wv p,E. WE'GNI CORNER WE 1 GH T IA)CORNER WEI GHT CO)CORNER WEIGHT(0)CORNER WEIGHT ID> ''H- 'J. •K'' "L' LBS. KG, Las.1 KG. LBS. KG, , LOS. KG. LBS. 00. LES KO. LBS. KG LEO, FT.-1 , NM FT.-IN. 111.±2„. FT.-IN. NM _F_T -IN PIM (1) Cliiall.11. . 49 TH.005 alo 335 44 _____20 _.IL____34,I ' I 40 00.9 180 so 151 73 239 -109 2;10-727 'V:;';77=-'-6-32 --3779'•-1/10 1 050 -----!2'L7:11T711)-; '''''uSE.-- 2,-2 7/15. .672 4816099 ea° 399 191 87 163 74 242 110 2e4 I 2S1: 2- 2/Er 378 V-5 VW 1060 ,2-9 11/15' 906 2'-2 7/16' 672 mow wes,4LITHx012 1o3S 469 48114.914 1050 476 ) • , 1 225 102 193 4/ 205 125 333 151 I 1' -2 7/8' 375 k 47-1 9/15' 1253 • 3',-()3/8" 024 7-10 MG' 979 0•60 1 _I r 238 103 19E, SO 299 131 MO 157 1 I'-2 7/8" 375 4'-1 5/16- 1253 3"-0 3/A. 7/I5'---6-7-S-- OUT54DE AIR 77 I,DIMENSIONS IN ( ARE IN mILLIMETERS. ,_ ,,,,,,,/: 2.e,CEN1ER OF GRAVITY. 7.),_ - ..V../ 5 3. 0" DIRECTION OE AIR FLOw, 4. 041 VERTICAL DISCHARGE UNIIS,MINOR):TO BE ATTACHE() TO ACCESSORY n050 cuno ONI.V.FOR HORIZONTAL OISCHARGE REAR aor0A1 TRUER CIIANT, THESE PRIER REO'D FOR USE CI rDvonsAABCLV SFS L'itt ..... i t ici,450„tEix-1 i12:%., -1 cnoTOREIDAPI4R/07A4013011/(21;;(3.:4,14., ""--'''-'.--•• .1,1 AcCES!IOH,PACcAGES- TREADED 9190 0E00 HOLE CONDUIT USE SIZES UNITS FIELD SUPPLIED FLANOES 5NOuLD 85 ATTACHED To 2*.I.1 In" ID02,I o'-3 ov I V' ------L--------SIZE - ' .-- 1/2. 34v 7/0'122.21 HORIZONTAL DISCHARGE MINK% AND ALL DUCTWORK 91)0111 D F IL TER/ECONOMIZER ACCESS PANEL-\\ , F/DuRADL ADE rtoW 003 . . 3,4, oNo. 1 1/0:(21341 BE 41150101)To THE FLANGES. ' '' ' 5.1.11111mUll CLEARANCE (LOCAL CODE5 DR JURISDICTION MAY CONDENSER C,0 I L-\\ r CoDNER 0 1/4 0401 1 J/4 144.41 ; (0331 1/2:1?1 OAS I I/4'131,01 prim?,NI - / ,),'01-SiRtA7R/LRA"E,E1,4071,1 -52.1)i-1 JSE-i-LEL:C11 I-15.,N-5/--.1 IT'71c1/*TP.!ij':ilL . FLUE SIDE AND COmALISTIGLE SuREACES, 110913 " 46 111cHES. le INCHES WIEN L1511,0 ACCESSORY FLUE DISCHARGE REFLECTOR • FE0B10P1125R HoOD G. 11011014 OF 0141 9 TO COIlausTIBLE SURFACES (WHEN NO7 MIND CUM ' 7 . / , FOR ROVER,DEPENDING 011 WIRE 5I2E. 00 (___-::•) 0 I MIL • ' k , I'-0 1/2'1470) = Duni CP BASE RAIL TO COMUSTIOLE SURFACES OMEN ROT USING CORNER.A..--........__ 4' C-3 1/9' \ F/ECONONI IIER CURER 0 INCHES. - --= C7931 - l' A. CONDENSER COIL FOR PROAER AIR FLOW 36 INc)515 4-----7------_-_-_--_ -----.'"--,-", ..- 0'-5 1/ NPANINA4Y10'5114:. IHE 11°F'''"M' m0 11 --I- "7=1°"' g "40 O. OVERHEAD,60 INCHES TO ASSIA,..PROPER CONDENSER FAN II OPERA T I OIL 4. SREEU VIPANSVOTouggolLgsNoNlonox II \ 1 [ PANEL , PFTlilltE,rltlIft c09[EN1 NG ' I'-0 6/8"-4y. I ------- I , 13201 (4 6111,,C. IB IN. PER liEC. ' Et:7 0 +iillp _J -......J._ Ru.5.*LA.lni 9. SEIRCFR UNIT AIX BLOCK OR CONCRETE WALLS 5/0001409 II ' ----./7-7---II 1 II - - ' 0991.too SURFACES, EUNNIre.09x SIDE,43(N. PER NEC. 4'-9 3/4' „ ,___I---e-e:-_-'.7.--.7. ____ r 6 44, HORIZONTAL SUPPLY AO RETURN END, 0 INCHES ITIE11 SHE (14577 " -----.-ALT:CONDENSATE : --I 0. o 0,,i,•4-01-2. 13/16' 2'-l' M35) 1 ALTERNATE CONDENSATE DRAIN IS USED. II 056114 OPENING G.W1111 THE ExCEPTIOI1 OE THE CLEARANCE FOR THE CONVIIIIEJER 11 Illik IS BASF:PAN COIL AND M51511011 SIDE AS STATED 114 NOTE•Se b 1 EFT ARO c. A PEROVADLE FENCE UR BARRICADE REOuIRES'HOI - . " (NI 1 c.k CLEARAIN7E. 9'41154(111 gli R.1WALDMOCKUP, 91" S-S i/ 1 0/ 1 - im- C71,S1 ' ‘ ; sumo I L „ f;:22-.20.)7/8' AIR I 2'-4 3/4' 5 n °PENIRG . (730] R I CH T 5 IDE I- 1 SIDE ii - -(:67/1 '' 1I \ 'VERTICAL' , ' ' , . ISPAII„1,002 "AnglAi,R4234161 ' '- '-L ' ' I --'I :03]- IF SET()N BASE RAIL.'9, • II-I I 1/4- r •_I u, Tit VERTICAL C5NTEI)OE GRAV I TY IS I'4't4831 9019005 (SS,I ''.., 1 / I 1 ' SUM.I'A III ,----'..' ANO 000, ; -I I 15041 FOR 012 AND 014 15/16._ •• 0,4 11/15' --- -. . ' __r 7. _.., ,RP FROM III'710770)1()F'ME BASE RA)L, 12S I.43 049,01 1 1- CI 203 ..4 0 0 -A'12IVNISILPTiT.IriiiZATaK,7117i= "E"ir°1-3""n I ,._2. °.-5 VIE. 2'' 'I ...°5 f a NV'jiMLrar;f Tir11.--- CORNER .1). CHART tELI,, ONLY) ------1 , • :„...„..Hi3a) en" 5 vir'DIA.'1231 FIELD CouTcoL wiRIZI-ircr ' MI'83 --. j F R ON T . U.-3 1/8 -C(MER'.C. 1 - \'''''' t)*E°•COI ,.... _. O 3447747Fiiikii;Wiiriikiiii-- -' -- 3.-6 I'd 1/7':ITI NPI BAB MIN 401,216011,001,40 00 [10731 -------- ...........____. Ms) gowmin.i R 194%14 NAT 545 MA,45.1JE/11.14008.Or ' '-----3[140)//14..--..".''"1 . 0•.0 3/10• ,.,.. , . 0',_4 • APAI.10/11.441R5/WWI G.014r 44141F41144012,' .11'• 4 Il ' 1,11-ELUTR.N:, 481*414005 1 , F0.-7 3/0. 7-• 318 . . (IOW__Z 11011 1"?•••P•1)1°..-E-M-Wgi. (2219) 0-0 3/E1 G 3 THA 1111 MAUI SuPKY MOCK-GUT Ili TIM ' nn, ' V-4 5/15' • -I -I',.0 0/Er 'W-3 13/15' •-, "Ar" 07191 0 _ . . ......._. ,..,7,, __ ,_____ . 03200 FILTER ACCESS PANEL ,8 'F'90'1.0P1.93E3%1E13 CONDENSER COIL .: ,.'1/ AIR PEFIING11 I CONTROL 130)le '1.." INDOOR FAN NTT& I '0 i / COMPRESSOR/ ouRNER Accts5 BLUER ACCESS P SE( : ,... ,.... PANELml.tb ....!......_,..---1010005AOLE 0 1110991 , di OURADLADE HOOD F IL TER /VITALI' ,/ J' ,Oisj Ire -,, ll ' , i OUTSIDE AIR :,"TI f r J , I _I 7/8 1 r.PFNINOr 't 2'-2 7/16. 0 , 1352) I q HORCZONTAI. i l' 1 .. 0"-3 5/10,' F -- 1 I Ai Ito® 6711 ---i • I ' I 1 .°' l'-,• i 0' 7" 0' 11/16 l''.-1191 (r-4 9/16" i D'.-73:1/4 I.----3-13 1------ .4.--i0 10,-.-- . -,, , ;1400 [914.41 FonK TRUCK SLOTS . C14,1 0-2 f1/16,- • 1 i''693 \ELECTR I CAL 0'43 7/16' 0 .2 1/4* E071 re5AIL 1651 709 LEFT SIDE DISCONNECT C214, (1114 8 PLACES) 'LOCATION • S. R I GHT SI DE FRONT wppLy AIR RETURN AIR E 5TD. CONDENSATE DnAiN To 041 .1 iiiml•mm.m.•m•••m••i•.m.i•.i•......_cri 4 • SU13 M I T T A L MicroMetl Roofcurbs for Carrier 48/50TC A/D08,A09,A/D12,D14; 50TCQ Part Number: D08-D12; A07,008-012; 50HCQ A07,D08-D09; FORM NO. 1282-20P DATE: 2/12 48/50TF,TM,HJ 008-014; 50TFQ 008-014; 5OHJQ 008-009 Units 0597 Series SUBMITTED TO COMPANY: 0597 Series Roofcurb Specifications (in inches) DRAWN BY: MicroMeti Part No. Carrier Part No. A Weight 0597-008A JOB NAME: N/q EQUIPMENT 8 90 lbs NOTES: 0597-011A N/A 11 104 lbs 0597-014A CRRFCURB003A01 14 118 lbs FEATURES w� Se rO� 0597-018A N/A 18 142 lbs g !` 0597-024A CRRFCUR[i004A01 24 164 lbs *Roofcurb sides and ends are 16 a. I galvanized steel,(058 min.) Opening for the bottom electrical "Gaskettng package provided. connections *Full perimeter wood nailer. (4)insulated deck pans "Assembly hardware not required. 1 3/4"Alt.drain hole Blocked top ��'� \comers �� NOTES: 15x1/16°-- j � 5/16 ,4.,....-0--" . 2" typ. 1.)Adjustable Pitched/Adjustable Height " Supply a, � 40 1/16" n I7"'-- � curbs and taller curbs are available.Contact r factory. ,Q ' Return air 2,)Attach ductwork to roofcurb.Flanges of 41111 duct rest on top of curb. 78 114„ 3/4' 3,)Roofcurbs are marked with the Carrier t part number. �' _....,-- 0K-- 3,) 50" 1 3/4"--001 �� p Corner Detail 4.)The standard MicroMetl curbs do not ,y p have service plate holes.If they are re- ,L ~`: quired,you must specify on the order, t#014 1"If using through the side of the curb ,,,p0: - NOTE: gas or electric connectors,you must specify A \ 9 service holes are required, Optional service plates: 0815-0597, CR0 _L_,_ OFOCURB SS ECTION 2„ f THIS DOCUMENT IS THE PROPERTY OF MICROMETL CORPORATION AND IS DELIVERED UPON THE EXPRESS CONDITION THAT THE CONTENTS WILL NOT BE DISCLOSED OR USED WITHOUT MICROMETL'S WRITTEN CONSENT. MICROMETL CORP.•3035 NORTH SHADELAND AVENUE,SUITE 300•INDIANAPOLIS,IN, 46226 •1-B00-662-4822 ••• MICROMETL SPARKS•202 SOUTH 18TH ST.•SPARKS,NV 89431•1-800.884-4682