Report (93) ,5-- e-S SA) ,/ ti I 8 711MNE" ; Fan Powered Terminals Submittal /;-4/e---) OFFICE COPY Prepared For: Date:June 4, 2017 American Heating Attn:Dennis Lawrence Customer P.O. Number: TBD 5035 SE 24th Ave RECEIVED Portland, OR 97202 JUN 2 8 201? Sold To: Job Name: American Heating Nespresso Tigard CITY OF TIIGARD 5035 SE 24th Ave 9585 SW Washington Square Rd BUILINSIGOMS1ON Portland, OR 97202 Tigard, OR 97223 TraneOregon is pleased to provide the enclosed submittal for your review and approval. KR oLGER Excellence in Air Distribution' Product Summary Table Of Contents: Krueger Fan Powered Terminals Product Submittals Item Tag(s) Qty Al FPB-01, FPB-02 2 - Constant or series configuration - ECM Motor - Mery 8 filter - Motor disconnect - Standard 1/2" dual density fiberglass liner - Controls field mounted and supplied by others - No heating coils ***Please see following literature*** Michael Fontaine TraneOregon Direct: 503-431-2520 Cell: 971-409-1042 Job Name Nepresso Tigard Date 06/02/2017G, 'n--ici Xj?, Architect Office Trane Oregon Engineer Preparer Michael Fontaine axone in Air Dishibolion Contractor American Heating Tag Type FPB-01,02 KQFS Analog-DDC Controls Ultra Quiet, VAV Fan Powered, Constant or Series Main Product KQFS Analog-DDC Controls 112"DIA. N DAMPER sHAI=Tn.-. 00 20" _ ALLOW CLEARANCE r -. tate" . III FOR CONTROLS" Ira^ �i fl hr4"---Ti . iMll1op I PRIMARY I i i 1 L AIR INLET rr I I I DISCHARGE bilk1 I } t [ I Iallli L A.iiii INDUCED I AIR INLET Y I 1414" SEHAONPTEONBARLA -RiES PBLCSJOW , B ___. ..«m1-112" L INLET VIEW PLAN VIEW—Left Hand Unit Shown DISCHARGE VIEW •Flow sensor shown above may not be actual provided sensor. See details below for actual sensor. Unit Size Inlet L W H A B D DD F G J 3-Cabinet Size 10-10 Inch 39.5 36.125 18.0625 15.125 15 9.875 4.875 11 14 3.125 X Y Z 9 7 2.625 Feature Benefits 4-ECM-120V 1-Phase •Electronically commutated motor(ECM)motor,mounted with vibration isolators. Page 1 of 5- Edge Version 2014.0.360 - Product Information is Subject to Change without notice A Job Name Neoresso Tigard Date 06/02/2017 , Architect Office Trane Oregon FIE] Ki?UEGE.i< Engineer Preparer Michael Fontaine *r item i Contractor American Heating Tag Type FPB-01.02 Air Distribution Feature Benefits(continued) Unit Size Motor HP Motor FLA 3-Cabinet Size 1/2 7.7 6-VCU-Manual Fan Control •The VCU fan speed control with digital display,alternating between RPM and percentage of full flow, is manually field set and is field adjustable. 3-K4 LineaCross 4 Quad •12-point total pressure,center averaging flow cross-type design. •Equal area layout. •Complies with ASHRAE's recommended measurement points for accurate determination of duct air velocity. N\ All.A, •CFM=K*(delta P)"(1/2) { •Illp \\.\ 00, �"- ^^ •Where CFM=ft^3/minute,delta P=Pressure Differential("WG)and K=Sensor Constant ",,,, ..„\,4/ \A/47 z 7\ Inlet K ,iiiiiw 10 10lnch 1432 Page 2 of 5 - Edge Version 2014.0.360- Product Information is Subject to Change without notice Job Name Nepresso Tigard Date 06/02/2017 Architect Office Trane Oreaon ICRUEGER Engineer Preparer Michael Fontaine ,.. Excellence in Air Distobulion Contractor American Heating Tag Type FPB-01,02 Construction Detail 1/2"thick,Dual Density Fiberglass Liner Physical Properties •Material:Dual Density Fiberglass •Thickness: 1/2 inch •R-Value: 1.9 @ 75°F •Density: 1.5 lbs/ft^3 with 4.0 lbs/ft^3 Face •Maximum Operating Temperature:250°F(121°C) •Maximum Air Velocity:3600 FPM •Flame Spread:Less than 25 •Smoke Density:Less than 50 •Mold Growth and Humidity: None •Edge Treatment:Sealant(NFPA 90A Approved) Code Compliances •UL 181 :Air Erosion •UL 181 : Mold Growth and Humidity •UL 723: Flame/Smoke Spread(25/50) •NFPA 255: Flame/Smoke Spread(25/50) •NFPA 90A&90B:Appliances •ASTM E84: Flame/Smoke Spread(25/50) •ASTM C1071 : Fiberglass Duct Liner Page 3 of 5 - Edge Version 2014.0.360 - Product Information is Subject to Change without notice Job Name Neoresso Tigard Date 06/02/2017 per UEGR aArchitect Office Trane Oregon ` KR Engineer Preparer Michael Fontaine Contractor American Heating Tag Type FPB-01.02 EXC011etirChe in Air I irttb 10011 Product Notes •20 Gage steel casing. •Control enclosure for electronic components with factory supplied 24V control transformer. •Unit utilize a round volume control damper with a solid shaft that rotates in self lubricating Delrin®bearings. •Damper blade incorporates a flexible gasket for tight airflow shutoff and operates over a full 90°rotation. •The damper position is marked by an arrow embossment on the end of the damper shaft. •Integral induced air attenuator. •Motor-blower isolation. •Removable bottom panel allows easy access to motor-blower assembly. •Primary airflow balancing connections. •Pressure independent primary flow control. •Single point electrical connections. •Rectangular discharge opening is designed for flanged duct connections. •*Check NEC for unit clearance requirements. Listing Image(s) 0 •Adherence to UL 1995 electrical safety. •AHRI certified sound data. wwwahridirect ory,nrg VAVTerrnmais ,.. AHRI Standard 880 Page 4 of 5 - Edge Version 2014.0.360 - Product Information is Subject to Change without notice Job Name Neoresso Tigard Date 06/02/2017 Architect Office Trane Oregon toT GER Engineer Preparer Michael Fontaine Excellence in Air Distribution Contractor American Heating Tag Type FPB-01,02 OptionSchedule Casing 1L-LH Controls,20 Gauge HW Coil 000-None Elec Coil 000-None Motor 4-ECM-120V 1-Phase Ctrl Accy 1 6-VCU-Manual Fan Control Ctrl Accy 2 0-None Control D000-Enclosure NO E-HEAT w/TRAN INC Liner 0-Standard Unit Accy 1 A-Motor Toggle Disconnect Unit Accy 2 M-Mery 8 Filter on Induced Inlet Unit Accy 3 0-None Unit Accy 4 0-None Unit Accy 5 0-None Unit Accy 6 0-None Coil Accy 1 0-None Coil Accy 2 0-None Coil Accy 3 0-None Coil Accy 4 0-None Coil Accy 5 0-None Sensor 3-K4 LineaCross 4 Quad Metric N-No(enter airflow as CFM) ID Quantity Tag Inlet Unit Size Fan CFM Max CFM Min CFM KW Fan Static 1 1 FPB-01 10-10 Inch 3-Cabinet Size 1000 1000 300 0 0.25 2 1 FPB-02 10-10 Inch 3-Cabinet Size 700 700 143 0 0.25 Page 5 of 5- Edge Version 2014.0.360 - Product Information is Subject to Change without notice TRAIVE' Submittal Prepared For: Date:June 05, 2017 All Bidders Job Name: Nespresso Tigard TI Trane U.S. Inc. is pleased to provide the enclosed submittal for your review and approval. Product Summary Qty Product 2 Tracer UC210 (BMUC) 2 End Devices and Sensors The attached information describes the equipment we propose to furnish for this project,and is submitted for your approval. Product performance and submittal data is valid for a period of 6 months from the date of submittal generation. If six months or more has elapsed David Strasser between submittal generation and equipment release,the product Trane performance and submittal data will need to be verified. It is the 7257 SW Kable Lane customer's responsibility to obtain such verification. Portland, OR 97224-7181 Phone: (503)620-8031 J:IJOBSI124166894121Sub Ver 1.doc Table Of Contents Product Summary , 1 Tracer UC210 (BMUC) (Item Al) 3 Tag Data 3 Product Data 3 Mechanical Specifications 4 Unit Dimensions 5 Field Wiring 6 End Devices and Sensors (Item B1) 7 Tag Data 7 Mechanical Specifications 8 Unit Dimensions 11 Field Wiring 14 Nespresso Tigard TI June 05,2017 Tag Data-Tracer UC210 BMUC) (Qty: 2) Item Tag(s) Qty Description Model Number Al No Tag 2 Tracer UC210 (BMUC) BMUC210AAAOT00011 Product Data-Tracer UC210(BMUC) Item: Al Qty: 2 Tracer UC210 Controller VAV Program Trane Actuator FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 3 of 15 Others Nespresso Tigard TI June 05,2017 Mechanical Specifications -Tracer UC210(BMUC) Item: Al Qty: 2 Features and Benefits BACnet MS/TP: -An open standard building automation communications protocol,which enables connections to other BAS systems and controllers. Configurable and fully programmable: -VAV programs available through quick configuration for lowest setup time -Programmable for flexibility to meet unique sequence or hardware needs Total of 14 built-in I/O points: -Meets the needs of most VAV applications with extra built-in I/O's available to network, or additional programming on controller Expandable to 22 points: -Flexibility to meet additional equipment needs Specifications: Storage environment Temperature From -40°F to 185°F (-40°C to 85°C) Relative Humidity: 5-95%, non-condensing Operating environment Temperature From -40°F to 158°F (-40°C to 70°C) Relative Humidity: 5-95%, non-condensing Power requirements Input: 20.4-27.6 Vac(24 Vac, ±15% nominal)50 or 60 Hz, 10.5 VA plus 1 VA per 20mA of 24 VDC load plus 12 VA maximum per binary load Environmental Rating (Enclosure) NEMA-1 enclosure Installation UL 840: Category 3 Pollution UL 840: Degree 2 Agency listings/compliance -UL916 PAZX-Open Energy Management Equipment -UL94-5V Flammability -CE Marked -FCC Part 15, Subpart B, Class B Limit -AS/NZS CISPR 22:2006 -VCCI V-3/2008.04 -ICES-003, Issue 4:2004 -Communications BACnet MS/TP, supports BACnet protocol ASHRAE 135-2004 and meets BACnet Testing Laboratory(BTL)as an Application Specific Controller(ASC) profile device -Suitable for plenum mounting FLD=Furnished by Trane U.S. Inc./Installed by Equipment Submittal Page 4 of 15 Others Nespresso Tigard TI June 05,2017 Unit Dimensions-Tracer UC21O(BMUC) Item: Al Qty: 2 1 7/16" (� Mtn ��I — \\1.4,'"iiitc-;-..' :•III, � � �.�.�. .. Hun LLil l it .-::::010:1414:, � � 4 3/4" it j E _ - .. F, 000 -�Ir =-1 LIQ• igim ...... N, !) IL 9 7/8" - r''‘' ' 1 � ming __ '►r•'!-i1 ^`,. 211/16" - - ■�_ IL Dili -'��1 ___ 'i–11'1- -",,. r jric) FLD=Furnished by Trane U.S. Inc./Installed by Equipment Submittal Page 5 of 15 Others Nespresso Tigard TI June 05,2017 Field Wiring-Tracer UC210 (BMUC) Item: Al Qty: 2 AIP BIP UIP 1-3 1 1-2 I I 1 I I I I I I •i► Imo jr AW1 \ 'btotd-A 'LII Er- min la ErEEI Hu . HL ,; a X51 I � 1 LmJ I I I s g I IL..I(I TI BED LT i 0: C ! ) i, 1 ii 0 ( !-x'1'1`1'1 ii '�I'� LI 4citt ,lam— .mmi.. . - I :I:: i ,1 - g N. - II I I I11 24 VAC L BO1-5 -I AOP 1-2 A WARNING AN AVERTISSEMENT A\ CAUTION HAZARDOUS VOLTAGEI VOLTAGE HASARDEUX! USE COPPER CONDUCTORS ONLY! DISCONNECT ALL ELECTRIC POWER DECONNECTEZ TOUTES LES SOURCES UNIT TERMINALS ARE NOT INCLUDING REMOTE DISCONNECTS ELECTRIQUES INCLUANT LES DESIGNED TO ACCEPT OTHER BEFORE SERVICING. DISJONCTEURS SITUES A DISTANCE TYPES OF CONDUCTORS. FAILURE TO DISCONNECT POWER AVANT D'EFFECTUER L'ENTRETIEN. FAILURE TO DO SO MAY CAUSE BEFORE SERVICING CAN CAUSE FAUTE DE DECONNECTER LA SOURCE DAMAGE TO THE EQUIPMENT. SEVERE PERSONAL INJURY OR ELECTRIQUE AVANT D'EFFECTUER DEATH. L'ENTRETIEN PEUT ENTRAINER DES BLESSURES CORPORELLES SEVERES OU LA MORT. FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 6 of 15 Others Nespresso Tigard TI June 05,2017 Tag Data- End Devices and Sensors (Qty: 2) Item Tag(s) Qty Description B1 No Tag 2 End Devices and Sensors X1351152801 Zone Temperature Sensor 41901129 4"Therm Duct 6' Lead Temp Sens X1379088601 —Sensor with Display, Setpoint TOV FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 7 of 15 Others Nespresso Tigard TI June 05,2017 Mechanical Specifications - End Devices and Sensors Item:B1 Qty: 2 Zone Temperature Sensor The zone sensor monitors the temperature of the specific building space where it is installed. The sensor senses zone temperature. A controller in the HVAC system uses the data to control the zone to a selected temperature. Enclosure The enclosure consists of three components: back plate, cover, and security screw. The back plate contains a circuit board and an optional COMM module, if installed. It also provides a wire cutout and mounting hole openings.The cover protects the circuit board and the optional COMM module. It provides openings for ventilation, switches, and indicators. A security screw is located at the bottom of the enclosure and anchors the cover to the back plate to help prevent tampering. Circuit board The circuit board snaps securely to the enclosure back plate. Depending on the model, it provides pushbutton switches, potentiometers controlled from the outside of the zone temperature sensor enclosure. Switches and a thumbwheel select features and functions of the sensor. Some zone sensor models have no switches. Optional COMM module The optional COMM module snaps securely to the enclosure back plate. It must be ordered separately and installed by the customer. If a COMM module is requested for a zone temperature sensor, the module ships enclosed in a separate package and is later installed as part of the sensor installation process. The COMM module consists of a small circuit board populated with an RJ22 jack and a termination block. The termination block provides connections between the RJ22 jack and the unit control module. The jack is the connection point for the PC Service Tool cable. Specifications Sensor operating temperature 32 to 122°F (0 to 50°C) Storage temperature -40 to 185°F (-40 to 85°C) Storage and operating humidity range 5%to 95%, non-condensing Accuracy 0.5°F over a range of 55 to 85°F (12.8 to 29.4°C) Housing Polycarbonate/ABS blend, UV protected, UL 94-5VA flammability rating, suitable for application in a plenum Mounting 3.24 in. (8.26 cm)for 2 mounting screws (supplied) Sensor Location Prior to installing a zone temperature sensor, the location must be determined. Together, these descriptions will enable you to choose the most effective sensor placement to ensure accurate readings and increase the longevity of the sensor. When selecting a location for the zone temperature sensor, rule out those with undesirable characteristics such as: Locations in the direct airstream of air diffusers Locations where exterior or other walls show a temperature difference between the two sides Locations close to sources of heat such as direct sunlight(on or near the sensor), appliances, equipment, concealed pipes, and chimneys Locations that are drafty Locations that are dead spots: behind doors, behind projection screens, and in corners Locations with walls that are subject to high vibration Locations with high humidity FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 8 of 15 Others Nespresso Tigard TI June 05,2017 Locations that are high traffic areas: to reduce the chance of accidental damage or tampering Locations to look for Height requirements for mounting the zone sensors are: Maximum height of 54 in. off the floor(measured from the bottom of the enclosure)for most installations Maximum height of 48 in. off the floor(measured from the bottom of the enclosure)when only a parallel approach, for example by a person in a wheelchair, is possible. Note: Consult section 4.27.3 of the 2002 Americans with Disability Act(ADA)guideline and local building codes for further details concerning wheelchair requirements. Zone Temperature Sensor The wired display sensor monitors the temperature of the specific building space where it is installed. The sensor displays zone temperature or setpoint and has other configurable options such as occupancy(timed override),fan, and system control. A controller in the HVAC system uses the sensor input to maintain the zone at a selected temperature. Sensor Enclosure The sensor enclosure consists of back plate, cover, security screw, and mounting hardware. It provides openings for ventilation. A security screw is located at the bottom of the enclosure and anchors the cover to the back plate to help prevent tampering. Occupancy(timed override) This optional function allows temporary control of the heating and cooling for the zone monitored by the temperature sensor which has reverted to unoccupied mode. Not all systems support this capability. Setpoint(single, dual or none) The setpoint and room temperature can be set to display in Fahrenheit or Celsius. The temperature resolution can be selected for tenths, halves,or whole numbers.The sensor can be set to display room temperature or setpoint depending on building owner preference. The sensor can be configured for dual setpoint, in which case the cooling and heating setpoints are adjusted independently. The sensor can also be configured for no setpoint control, where only fan control is required. The sensor ships configured for single or dual setpoint in Fahrenheit,with whole degree resolution. The room temperature is displayed by default for all options. Fan Control The sensor can be configured for up to five fan settings; off, auto, low, medium or high. The available fan options are limited by the setpoint and system options chosen. System Control The sensor can be configured for up to five system settings; off, auto, cool, heat, or emergency heat. The system choices are limited by the setpoint option chosen. Specifications Sensor operating temperature 32 to 122°F (0 to 50°C) Setpoint functional range 50 to 89.6°F (10 to 32°C) Storage/operating humidity range 5%to 95% relative humidity(RH), noncondensing Storage temperature -40 to 185°F (-40 to 85°C) Storage and operating humidity range 5%to 95%, non-condensing Accuracy 0.5°F over a range of 55 to 85°F (12.8 to 29.4°C) Housing Polycarbonate/ABS blend, UV protected, UL 94-5VA flammability rating Mounting FLD=Furnished by Trane U.S. Inc./Installed by Equipment Submittal Page 9 of 15 Others Nespresso Tigard TI June 05,2017 3.24 in. (8.26 cm)for 2 mounting screws (supplied) Agency Compliance United States UL listed: UL94, 5 VA flammability rating and UL916, energy management equipment FCC Part 15, Subpart B Canada CUL-C22.2 No. 205-M1983 Signal Equipment Industry Canada (Certificate No.: IC6178A-13651127) Europe EMC Directive 89/336/EEC (EMC emissions and susceptibility) EN61326-Commercial Application Emissions EN55011:2007 Class B limit Immunity EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 EN61000-4-6 EN61000-4-11 Sensor Location Prior to installing a zone temperature sensor,the location must be determined. Together, these descriptions will enable you to choose the most effective sensor placement to ensure accurate readings and increase the longevity of the sensor. When selecting a location for the zone temperature sensor, rule out those with undesirable characteristics such as: Locations in the direct airstream of air diffusers Locations where exterior or other walls show a temperature difference between the two sides Locations close to sources of heat such as direct sunlight(on or near the sensor), appliances, equipment, concealed pipes, and chimneys Locations that are drafty Locations that are dead spots: behind doors, behind projection screens, and in corners Locations with walls that are subject to high vibration Locations with high humidity Locations that are high traffic areas: to reduce the chance of accidental damage or tampering Locations to look for Height requirements for mounting the zone sensors are: Maximum height of 54 in. off the floor(measured from the bottom of the enclosure)for most installations Maximum height of 48 in. off the floor(measured from the bottom of the enclosure)when only a parallel approach, for example by a person in a wheelchair, is possible. Note: Consult section 4.27.3 of the 2002 Americans with Disability Act (ADA)guideline and local building codes for further details concerning wheelchair requirements. FLD=Furnished by Trane U.S. Inc./Installed by Equipment Submittal Page 10 of 15 Others Nespresso Tigard TI June 05,2017 Unit Dimensions- End Devices and Sensors Item: 131 Qty: 2 ACCESSORY TYPE OF ACCESSORY 4190-1129 4"DUCT THERM TEMP SENSOR 72"LEAD 4 .1111111 4' ( 1 1/2' ..• ' ' 1/4'dia 2. SPECIFICATIONS: PACKAGE: MOUNTING DUCT WIRING CONNECTION 7T,2 WIRE LEAD SENSOR: TEMP RANGE -30.0 F to 220.0 F SENSING ELEMENT THERMISTOR RESISTANCE 10,000 OHMS AT 77.0 F ACCURACY +/-.36 F[.2 C]from 32.0 F to 158.0 F MOUNTING NOTES: 1. MOUNT TEMPERATURE SENSOR IN DUCT WHERE THE AIRSTREAM IS TYPICAL OF THE AIR TEMPERATURE 2. MOUNT AT FLAT SURFACE OF DUCT. CUSTOMER CONNECTIONS: RED — EN, — — ELEMENT — TO ANALOG GRN ® NPUT CUT AND TAPE SHIELD CUSTOMER NOTE: 1. COMPONENTS AND WIRING SHOWN DASHED ARE FURNISHED AND INSTALLED BY CUSTOMER. 2. ALL CUSTOMERS WIRING MUST BE IN ACCORDANCE WITH NATIONAL ELECTRIC CODES AND LOCAL CODES. 3. ANALOG INPUT WIRING MUST BE 18 GA.SHIELD TWISTED PAIR(WIRE#400-20-28,Q-4166 OR EQUIVALANT.)SHIELD MUST BE CUT BACK AND TAPED AT SENSOR. 4� WARNING /\ ADVERTISSEMENT A\ CAUTION HAZARDOUS VOLTAGE! VOLTAGE HASARDEUX! USE COPPER CONDUCTORS ONLY! DISCONNECT ALL ELECTRIC POWER DECONNECTEZ TOUTES LES SOURCES UNIT TERMINALS ARE NOT INCLUDING REMOTE DISCONNECTS ELECTRIQUES INCLUANT LES DESIGNED TO ACCEPT OTHER BEFORE SERVICING. DISJONCTEURS SITUES A DISTANCE TYPES OF CONDUCTORS. FAILURE TO DISCONNECT POWER AVANT D'EFFECTUER L'ENTRETIEN. FAILURE TO DO SO MAY CAUSE BEFORE SERVICING CAN CAUSE FAUTE DE DECONNECTER LA SOURCE DAMAGE TO THE EQUIPMENT. SEVERE PERSONAL INJURY OR ELECTRIQUE AVANT D'EFFECTUER DEATH, L'ENTRETIEN PEUT ENTRAINER DES BLESSURES CORPORELLES SEVERES OU LA MORT. FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 11 of 15 Others Nespresso Tigard TI June 05,2017 Unit Dimensions- End Devices and Sensors Item: B1 Qty: 2 X1351152801 Zone Sensor Sensor 11 2 7/8" 1 1/16" mon1/16" - - I� I C 1 3/8" i 31/8' 411/16' 1 Ili ® Ii 1111 1_111.11II 9/16' ®—N111 lil FRONT RIGHT 01/8" BACK 1/4" TYP 2. 6 a" ; COVER REMOVED FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 12 of 15 Others Nespresso Tigard TI June 05,2017 Unit Dimensions- End Devices and Sensors Item: B1 Qty: 2 \ t?'"'" iiii n, . 915/16" I t IiiriPHIM 2 7/8" 1 1/16" �- - 1/8" .�_�_ � CUTOUT I i i i i 4 3/4" 3 3/8" i 0 O i #4121.' 1/4" �� . ..„._ 7 L________ 9/16" — �, 01/8"TYP 1 5/16" MOUNTING BASE IIIIMFAMM 2 5/8" FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 13 of 15 Others Nespresso Tigard TI June 05,2017 Field Wiring - End Devices and Sensors Item: B1 Qty: 2 X1351152801 Zone Sensor Zone Temperature RT1 thermistor, Oji 1 10K OHM AT 25 DEG C Signal Common /' 2 COMM module Optional Component _2 / 1(-) X13651467-01 J1 3 /2(+) FLD=Furnished by Trane U.S. Inc./Installed by Equipment Submittal Page 14 of 15 Others Nespresso Tigard TI June 05,2017 Field Wiring - End Devices and Sensors Item: B1 Qty: 2 ;e;aezla-ec;'etz-e?Ctt4: 4'ec',1 \\\ .�// . ® RJ22 \\� 4t.; )- �\0�I, II COMMUNICATION �� 0. 11 -'�7,1`l,. JACK FOR CONNECTING 11 24 VAC/VDC `'�'�1\1• SERVICE TOOL 10 47 (GROUND) a 4'���� 8 %ALLvir, Z 7 COMM- ' 6 COMM+ /\\ 5 HEAT SETPOINT(HSP) \ 4 SYS/FAN MODE (MODE) 3 SETPOINT Otrg 1 2 SIGNAL COMMON (COMMON) 1 ZONE TEMPERATURE(ZONE TEMP) FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 15 of 15 Others