Loading...
Report DN-60602:A1 FireWarden-100-2(E) Rev 3 NOTIFIER® Intelligent Addressable FACP by Honeywell Addressable Fire Alarm Control Panel General The Notifier FireWarden-100-2 Rev 3(NFW2-100)with Version 5.0 firmware is a combination FACP(Fire Alarm Control Panel) and DACT(Digital Alarm Communicator/Transmitter) all on one circuit board.This compact intelligent addressable control panel has an extensive list of powerful features. The SLC(Signaling Line Circuit)of the FireWarden-100-2 Rev 3 operates using a Rapid Group Polling communication protocol technology that polls multiple devices simultaneously for a quicker device response time.This patented technology allows a a fully-loaded panel with up to 198 devices to report an incident and activate the notification circuits in under 10 seconds. With °j this improved polling,devices can be wired on standard twisted, unshielded wire up to a distance of 10,000 feet. r The's quick-remove chassis protects the electronics during con- -4 struction. The backbox can be installed allowing field wiring to be pulled.When construction is completed,the electronics can be quickly installed with just two bolts. New features for Rev 3 with Version 5.0 firmware include removable terminal blocks, improved transient protection, addi- 0 tional secondary ANN-BUS,and increased power for the reset- • table and remote sync outputs. Available accessories include ANN-BUS devices as well as ACS LED, graphic and LCD annunciators, and reverse polarity/city box transmitter. The integral DACT transmits system status (alarms,superviso- ries, troubles, AC loss, etc.) to a Central Station via the public • Remote site or local USB port upload/download, using PS- switched telephone network.It also allows remote and local pro- Tools. gramming of the control panel using the PS-Tools Upload/Down- • Four (4) Style Y (Class B) NAC circuits, which can be con- load utility.In addition,the control panel may be programmed or verted to four (4) Style Z (Class A) circuits with optional interrogated off-site via the public switched telephone network. ZNAC-92 converter module. (Up to 6.0 amps total NAC Any personal computer with Windows®XP or greater, a com- power when using optional XRM-24B.) patible modem, and PS-Tools—the Upload/Download software • Selectable strobe synchronization for System Sensor,Whee- kit—may serve as a Service Terminal.This allows download of lock,and Gentex devices. the entire program or upload of the entire program, history file, • Remote Acknowledge, Silence, Reset and Drill via address- walktest data, current status and system voltages. The panel able monitor modules or FDU-80, N-ANN-80 or Legacy ACS can also be programmed through the FACP's keypad or via a Annunciators. standard PS-2 computer keyboard, which can be plugged directly into the printed circuit board.This permits easy typing of • ANN-BUS for connection to following optional modules(cannot address labels and other programming information. be used if ACS annunciators are used): Version 5.0 firmware supports the following: Primary and Sec –N-ANN-80(-W)Remote LCD Annunciator ondary ANN-bus devices,NP-Al 00,USB port,NAC circuit diag- –N-ANN-I/O LED Driver nostics,a new report has been added to the walk-test that lists –N-ANN-S/PG Printer Module untested devices, new device types added: audio telephone –N-ANN-RLY Relay Module type code for NFV-25/50ZST,Photo Supervisory and auto-reset- –N-ANN-LED Annunciator Module table Drill(non latching). –N-ANN-RLED Annunciator Module alarms only The FireWatch Series internet monitoring modules IPDACT-2 –ROME Relay Option Module Enclosure and IPDACT-2UD permit monitoring of alarm signals over the Internet saving the monthly cost of two dedicated business tele • ACS&Terminal-mode Annunciators: phone lines. Although not required, the secondary telephone –ACS Annunciators:Up to 32 Legacy ACM Series annuncia- line may be retained providing backup communication over the tors (ACM-16AT or ACM-32 series). Cannot be used if public switched telephone line. ANN-BUS devices are used. NOTE: Unless otherwise specified, the term FireWarden-100-2" –Terminal-mode Annunciators: Up to 32 Legacy FDU-80 is used in this document to refer to both the Fire Warden-100-2 and annunciators. the FireWarden-100-2E FACPs(Fire Alarm Control Panels). Like- • EIA-232 printer/PC interface(variable baud rate)on main cir- wise, "NFW2-100"refers to NFW2-100E as well. cuit board,for use with optional UL-listed printer PRN-6. • Integral 80-character LCD display with backlighting. Features • Real-time clock/calendar with automatic daylight savings • Listed to UL standard 864,9th edition. control. • On-board DACT. • Detector sensitivity test capability(NFPA 72 compliant). DN-60602:A1•12/07/2010—Page 1 of 6 • History file with 1,000-event capacity. • Ground Fault(yellow) • Maintenance alert warns when smoke detector dust accumu- KEYPAD CONTROLS lation is excessive. • Automatic device type-code verification. • Acknowledge/Step • One person audible or silent walk test with walk-test log and • Alarm Silence printout. • Drill • Point trouble identification. • System Reset(lamp test) • Waterflow(nonsilenceable)selection per monitor point. • 16-key alpha-numeric pad(similar to telephone keypad) • System alarm verification selection per detector point. • 4 cursor keys • PAS(Positive Alarm Sequence)and presignal delay per point • Enter (NFPA 72 compliant). NOTE:Only detectors may participate in PAS. Product Line Information SLC LOOP: NFW2-100: FireWarden-100-2 Rev 3 198-point addressable • SLC can be configured for NFPA Style 4,6,or 7 operation. Fire Alarm Control Panel, one SLC loop. Includes 80-character • SLC supports up to 198 addressable devices per loop (99 LCD display, single printed circuit board mounted on chassis, detectors and 99 monitor,control,or relay modules). and cabinet. 120 VAC operation. • SLC loop maximum length 10,000 ft.(3,000 m.). NFW2-100R:Same as NFW2-100,except in a red backbox. See installation manual for wire tables. NFW2-100E:Same as NFW2-100,except with 240 VAC opera- NOTIFICATION APPLIANCE CIRCUITS(NACS): tion. Four onboard NACs with additional NAC capability using out 4XTM Reverse Polarity Transmitter Module: Provides super- • put control modules (NC-100). The four Class B NACs can vised output for local energy municipal box transmitter, alarm, and trouble. be converted to four Class A NACs with optional ZNAC-92 converter module. ZNAC-92: Optional converter module which converts four (4) • Silence Inhibit and Auto Silence timer options. Style Y(Class B) NAC circuits to four(4) Style Z(Class A)cir- cuits. • Continuous, March Time, Temporal or California code for PS Tools: Programming software for Windowse-based PC main circuit board NACs with two-stage capability. 9 9 • Selectable strobe synchronization per NAC. computer(cable not included),available on www.firelite.com. • 2.5 amps maximum per each NAC circuit. DP-9692B:Optional dress panel for FireWarden-100-2 Rev 3. NOTE:Maximum 24VDC system power output is shared among TR-CE-B:Optional trim Ring for semi-flush mounting. all NAC circuits and 24VDC special-application auxiliary power BB-26: Battery backbox, holds up to two 26 AH batteries and outputs. Total available output is 3.0 amps. Using the optional CHG-75. XRM-24B transformer increases 24VDC output to 6.0 amps. NFS-LBB:Battery box,houses two 55 AH batteries. PROGRAMMING AND SOFTWARE: CHG-75: Battery charger for lead-acid batteries with a rating of • Autoprogram(learn mode)reduces installation time. 25 to 75 AH. • Custom English labels (per point) may be manually entered CHG-120: Remote battery charging system for lead-acid batter- or selected from an internal library file. ies with a rating of 55 to 120 AH. Requires additional NFS-LBB • Three Form-C relay outputs(two programmable). for mounting. • 99 software zones. NOTE: CHG-120 or CHG-75 required for batteries larger than • Continuous fire protection during online programming at the 18AH. front panel. BAT Series:Batteries,see data sheet DN-6933. • Program Check automatically catches common errors not XRM-24B(E): Optional transformer. Increases system power linked to any zone or input point. output to 6.0 amps. Use XRM-24BE with FireWarden-100-2E • OFFLINE PROGRAMMING: Create the entire program in Rev 3. your office using a Windows®-based software package PRT/PK-CABLE: Cable printer/personal computer interface (NFW2-100 requires PS-Tools Programming software,avail- cable; required for printer or for local upload/download program- able on www.magni-fire.com). Upload/download system pro- ming and updating panel firmware. gramming locally to the NFW2-100 Rev 3 in less than one PRN-6: UL listed compatible event printer. Uses tractor-fed minute. paper. • USB upload/download programming with standard Male-A to IPDACT2/2UD, IPDACT Internet Monitoring Module: Mounts Male-B cable. in bottom of enclosure with optional mounting kit(PN IPBRKT). Connects to primary and secondary DACT telephone output User Interface ports for internet communications over customer provided ether- netLED INDICATORS Internet connection. Requires compatible Teldat VisorALARM Central Station Receiver.Can use DHCP or static • AC Power(green) IP.(See data sheet DN-60408 for more information.) • Fire Alarm(red) IPBRKT:Mounting kit for IPDACT-2/2UD in common enclosure. • Supervisory(yellow) IPSPLT:Y-adaptor option allows connection of both panel dialer • Alarm Silenced(yellow) outputs to one IPDACT-2/2UD cable input. • System Trouble(yellow) COMPATIBLE ANNUNCIATORS • Maintenance/Presignal(yellow) N-ANN-80(-W): LCD Annunciator is a remote LCD annunciator • Disabled(yellow) that mimics the information displayed on the FACP LCD display. • Battery Fault(yellow) Recommended wire type is un-shielded. (Basic model is black; order-W version for white;see DN-7114.) Page 2 of 6—DN-60602:A1•12/07/2010 N-ANN-LED:Annunciator Module provides three LEDs for each Appliance Circuit option requires external 24 VDC to power noti- zone: Alarm, Trouble and Supervisory. Ships with red or black fication appliances. enclosure(see DN-60242). NC-100R: Addressable relay module containing two isolated N-ANN-RLED: Provides alarm(red)indicators for up to 30 input sets of Form-C contacts, which operate as a DPDT switch. zones or addressable points.(See DN-60242). Mounts directly to a 4.0" (10.16 cm.) box, surface mount using N-ANN-RLY: Relay Module, which can be mounted inside the the SMB500. cabinet, provides 10 programmable Form-C relays. (See DN- NOT BG12LX: Addressable manual pull station with interface 7107.) module mounted inside. ROME-B: Relay Option Module Enclosure (order ROME-B for N100-ISO: Fault Isolator Module.This module isolates the SLC black or ROME for red). Provides one N-ANN-RLY Relay Mod- loop from short circuit conditions(required for Style 6 or 7 oper- ule already installed. The ROME Series provides mounting ation). space for one additional Relay Module or one addressable Multi- SMB500:Used to mount all modules except the NMM-100P. module. (See Installation Sheet PN 53530.) NMM-100-10: Ten-input monitor module. Mount one or two N-ANN-S/PG: Serial/Parallel Printer Gateway module provides modules in a BB-XP cabinet(optional).Mount up to six modules a connection for a serial or parallel printer.(See DN-7103.) on a CHS-6 chassis in a BB-25. N-ANN-I/O: LED Driver Module provides connections to a user NZM-100-6: Six-zone interface module for compatible conven- supplied graphic annunciator.(See DN-7105.) tional two-wire detectors.Mount one or two modules in a BB-XP ACM-8R:Relay module provides 8 Form-C 5.0 amp relays. cabinet(optional). Mount up to six modules on a CHS-6 chassis ACM Annunciator Series: LED-type fire annunciators capable in a BB-25. of providing up to 99 software zones of annunciation.Available NOTE:For more information on Compatible Addressable Devices in increments of 16 or 32 points to meet a variety of applications. for use with the Fire Warden-100-2 Rev 3, see the following data LDM Graphic Series: Lamp Driver Module series for use with sheets(document numbers):N100 ISO(DN-6994),NP-100 series custom graphic annunciators. (DN-6995),NI-100(DN-6996),NH-100 series(DN-6997),ND-100 series (DN-7006), NP-A100 (DN-6998), NMM-100/NMM-100P/ FDU-80(Liquid Crystal Display)point annunciator:80-char- NDM-100/NZM-100 (DN-6999), NC-100/NC-100R (DN-7000), acter, backlit LCD-type fire annunciators capable of displaying NOT-BG12LX (DN-7001), NMM-100-10 (DN-6990), and NZM- English-language text. 100-6(DN-60150). NOTE:For more information on Compatible Annunciators for use with the Fire Warden-100-2 Rev 3, see the following data sheets Wiring Requirements (document numbers)ACM-8R(DN-3558),ACS/ACM Series(DN- While shielded wire is not re wired, it is recommended that all 0524),LDM Series(DN-0551),FDU-80(DN-6820). q SLC wiring be twisted-pair to minimize the effects of electrical COMPATIBLE ADDRESSABLE DEVICES interference.Wire size should be no smaller than 18 AWG(0.78 All feature a polling LED and rotary switches for addressing. mm2) and no larger than 12 AWG (3.1 mm2). The wire size depends on the length of the SLC circuit. Refer to the panel NI-100:Addressable low-profile ionization smoke detector. manual for wiring details. NP-100:Addressable low-profile photoelectric smoke detector. NP-100T:Addressable low-profile photoelectric smoke detector with thermal sensor. NP-100R: Addressable remote test capable detector for use with DNR(W)duct smoke detector housings. NH-100:Fast-response,low-profile heat detector. NH-100R: Fast-response, low-profile heat detector with rate-of- rise option. NH-100H: Fixed high-temperature detector that activates at 190F/88C. NP-A100:Addressable low-profile multi-sensor detector. DNR: Innovair Flex low-flow non-relay duct-detector housing. Order NP-100R separately. DNRW: Innovair Flex low-flow non-relay duct-detector housing, with NEMA-4 rating. Watertight.(Order NP-100R separately.) NMM-100: Addressable Monitor Module for one zone of nor- mally-open dry-contact initiating devices. Mounts in standard 4.0"(10.16 cm.)box.Includes plastic cover plate and end-of-line resistor.Module may be configured for either a Style B(Class B) or Style D(Class A) IDC. NDM-100: Dual Monitor Module. Same as NMM-100 except it provides two Style B(Class B)only IDCs. NMM-100P: Miniature version of NMM-100. Excludes LED and Style D option.Connects with wire pigtails.May mount in device backbox. NZM-100: Similar to NMM-100, but may monitor up to 20 con- ventional two-wire detectors. Requires resettable 24 VDC power.Consult factory for compatible smoke detectors. NC-100: Addressable Control Module for one Style Y/Z (Class B/A) zone of supervised polarized Notification Appliances. Mounts directly to a 4.0" (10.16 cm.)electrical box. Notification DN-60602:A1•12/07/2010—Page 3 of 6 Fire Warden-100-2 Rev 3 4 Fire Alarm Control/ n ANN-BUS Communicator or ANN-BUS DEVICES EIA-485 _ N-ANN-80,N-ANN-LED, in ACS mode • ► 411 , , ,r) N-ANN-S/PG,N-ANN-I/O (two wires) e SMOKE DETECTORS L NP-100,NP-100T, 24 VDC NI-100,NP-A100 O. I Ir .1 I Optional 11 my n= 4 a REVERSE HEAT DETECTORS M0 nM POLARITY/ M0 OM _ CITY BOX NH-100,NH-100R,NH-100H M0 0: OUTPUT =o n= M101 CIE (4XTM)MCI UM ► ANNUNCIATORS • i ♦ ♦ ♦ ♦ l ♦ (I.: 1111 ACS/ACM,LDM 8 FORM-C,5-AMP RELAYS DUCT DETECTORS NOTE:System can use (optional,order ACM-8R) ND-100,ND-100R,DNR either ANN-BUS devices OR ACS-mode annunciators. rtThey cannot be usedsimultaneously. NACs(NotificationAppliance Circuits) ► BELLS,SIGNALS,STROBES MONITOR/CONTROL NMM-100,NZM-100, NDM-100,N100-ISO, EIA-232 NC-100,NC-100R INTERFACE (PIM-24)built into the motherboard .® P. mit 11111 /—� .0 0 0 0 0 ..„, —+ ADDR® ® ABLE MULTI-MODULE PRINTER NZM-100-6,NMM-100-10 NOTE:System can use either the printer OR the FDU-80. They 1!>e! cannot be used simultaneously. �---�-- EIA-485 24 VDC ► INTERFACE a 1 (four wires) r MINI-MONITOR ► NMM-100P • • FIRE FDU-80 ► Up to 6,000 ft.(1825.8 m) between each FDU-80 in . O. the EIA-485 loop,and between PULL STATION each FDU-80 and the FACP. NOT-BG12LX Page 4 of 6—DN-60602:A1•12/07/2010 SYSTEM SPECIFICATIONS C CATIONS System Capacity (42.29 cm.)wide x 5.20" (13.34 cm.)deep.Trim Ring(TR-CE- B):22.00"(55.88 cm.)high x 19.65"(49.91 cm.)wide. • Intelligent Signalling Line Circuits 1 • Addressable device capacity 198 Shipping Specifications • Programmable software zones 99 • ACS Annunciators 32 Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.) high x 22.5"(57.15 cm.)wide x 8.5"(21.59 cm.)deep. • ANN-bus devices 16 Electrical Specifications Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 — AC Power: FireWarden-100-2 Rev 3: 120 VAC, 60 Hz, 3.0 49°C/32—120°F and ata relative humidity 93%±2%RH(non- amps. FireWarden-100-2 Rev 3(E):240 VAC,5 0 Hz, 1.5 amps. condensing) at 32°C ±2°C (90°F ±3°F). However, the useful Wire size:minimum 14 AWG(2.00 mm2)with 600 V insulation. life of the system's standby batteries and the electronic compo- Battery charger capacity:7 AH-18 AH batteries.Up to two 18 nents may be adversely affected by extreme temperature ranges Ah batteries can be housed in the FACP cabinet. Larger batter- and humidity. Therefore,it is recommended that this system and ies require an external battery charger such as the CHG-75 or its peripherals be installed in an environment with a normal room CHG-120,and a separate battery cabinet such as the BB-26 or temperature of 15—27°C/60—80°F NFS-LBB. Communication Loop:Supervised and power-limited. NFPA Standards Notification Appliance Circuits: Each terminal block provides The FireWarden-100-2 Rev 3 complies with the following NFPA connections for two Style Y(Class B)for a total of four Style Y 72 Fire Alarm Systems requirements: (Class B)or with an optional ZNAC-92 module converts to four _LOCAL (Automatic, Manual, Waterflow and Sprinkler Style Z(Class A) NACs. Maximum signaling current per circuit: Supervisory). 2.5 amps. End-of-Line Resistor:4.7K ohm, 1/2 watt(P/N 71252 UL listed)for Style Y(Class B)NAC.Refer to panel documenta- —AUXILIARY (Automatic, Manual and Waterflow) (requires tion and Notifier Device Compatibility Document for listed com- 4XTM). patible devices. —REMOTE STATION (Automatic, Manual, Waterflow and Two Programmable Relays and One Fixed Trouble Relay: Sprinkler Supervisory)(Where a DACT is not accepted,the Contact rating:2.0 amps @ 30 VDC(resistive),0.5 amps @ 30 alarm,trouble and supervisory relays may be connected to VAC(resistive).Form-C relays. UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble,4XTM is required.) Special Application Non-resettable Power (24 VDC Nomi- —PROPRIETARY (Automatic, Manual,Waterflow and Sprin- nal):Jumper selectable(JP4)for conversion to resettable power kler Supervisory). output. Up to 1.0 amp total DC current available from each out- put.Power-limited. —CENTRAL STATION (Automatic, Manual, Waterflow and Special Application Resettable Power (24 VDC nominal): Sprinkler Supervisory). Jumper selectable(JP6)for conversion to non-resettable power. —OT,PSDN(Other Technologies,Packet-switched Data Net- Up to 1.0 amp total DC current available. Refer to the Notifier work) Device Compatibility Document for listed compatible devices. Remote Sync Output: Remote power supply synchronization Agency Listings and Approvals output. Nominal special application power: 24 VDC. Maximum The listings and approvals below apply to the basic FireWarden- current:300 mA. End-of-Line Resistor:4.7K ohm.Output linked 100-2 Rev 3 control panel. In some cases,certain modules may to NAC 1 control.Supervised and power-limited. not be listed by certain approval agencies, or listing may be in Telephone Interface: Unless used with Teldat VISORALARM, process.Consult factory for latest listing status. requires dedicated business telephone number with a minimum • UL Listed:S635 of 5 volts DC (off-hook voltage). Obtain dedicated phone line • FM approved directly from your local phone company. Do not use shared phone lines or PBX(digital)type phone line extensions. • CSFM:7165-0028:0235 • MEA: 120-06-E,Volume 2 Cabinet Specifications For ULC-listed version,see DN-60600. Door: 19.26"(48.92 cm.)high x 16.82"(42.73 cm.)wide x 0.12" (.30 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" NOTIFIER® is a registered trademark of Honeywell International Inc. Wheelock®is a registered trademark of and ExcederTM is a trademark of Cooper Notification. ©22010 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. C E R T F I E O We cannot cover all specific applications or anticipate all requirements. M7 IUIIMBIIII S MNMFMTIMM All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 6 of 6—DN-60602:A1•12/07/2010 dn-7114:c•A1-65 N-ANN 80 NOTIFIER® 80-Character LCD Serial Annunciator by Honeywell Annunciators General The N-ANN-80 annunciator is a compact, backlit, 80-character LCD fire annunciator that mimics the Fire Alarm Control Panel (FACP) display. It provides system status indicators for AC Power, Alarm,Trouble, Supervisory, and Alarm Silenced condi- tions. The N-ANN-80 and the FACP communicate over a two- wire serial interface employing the ANN-BUS communication format. Connected devices are powered, via two additional wires, by either the host FACP or a remote UL-listed, filtered power supply. N-ANN-80 is black;for white order N-ANN-80-W. The N-ANN-80 displays English-language text of system point information including device type, zone, independent point alarm, trouble or supervisory status, as well as any custom alpha labels programmed into the control panel. It includes con- trol switches for remote control of critical system functions. (A keyswitch prevents unauthorized operation of the control switches.) Up to eight N-ANN-80s may be connected to the ANN-BUS of each FACP. Minimal programming is required,which saves time during system commissioning. The N-ANN-80 is compatible with NOTIFIER FACPs with an ANN-BUS,such as the NFW-50. Features • Trouble • Supervisory • Listed to UL Standard 864,9th Edition. • Alarm Silenced • Backlit 80-character LCD display(20 characters x 4 lines). • Mimics all display information from the host panel. Specifications • Control switches for System Acknowledge, Signal Silence, • Operating voltage range: 18 VDC to 28 VDC. Drill,and Reset. •• Control switches can be independently enabled or disabled Current consumption 24 VDC nominal(filtered and non- at the FACP. resettable):40 mA maximum. • Keyswitch enables/disables control switches and0°F(0°C• to 49locks annunciator enclosure • Relative humidity: 93%±2%RH (noncondensing)at 32°C • Keyswitch can be enabled or disabled at the FACP. ±2°C(90°F±3°F). • Enclosure supervised for tamper. • 5.375" (13.65 cm.) high x 6.875" (17.46 cm.) wide x 1.375" (3.49 cm.)deep. • System status LEDs for AC Power,Alarm, Trouble, Supervi • For use indoors in a dry location. sory,and Alarm Silence. • • Local sounder can be enabled or disabled at the FACP. All connections are power-limited and supervised. • N-ANN-80 connects to the ANN-BUS terminal on the FACP Agency Listings and Approvals and requires minimal panel programming. g Y 9 pp • Displays device type identifiers, individual point alarm, trou- The listings and approvals below apply to the N-ANN-80. In ble,supervisory,zone,and custom alpha labels. some cases, certain modules may not be listed by certain • Time-and date display field. approval agencies,or listing may be in process. Consult factory • Surface mount directly to wall or to single, double, or 4" for latest listing status. square electrical box. • UL:S635 • Semi-flush mount to single, double, or 4" square electrical • FM approved box.Use ANN-SB8OKIT for angled view mounting. • CSFM:7120-0028:240 • Can be remotely located up to 6,000 feet(1,800 m)from the • MEA:442-06-E Vol.2 panel. • Backlight turns off during AC loss to conserve battery power The ANN-BUS but will turn back on if an alarm condition occurs. • May be powered by 24 VDC from the host FACP or by remote POWERING THE DEVICES ON THE ANN-BUS FROM power supply(requires 24 VDC). AUXILIARY POWER SUPPLY • Up to eight N-ANN-80s can be connected on the ANN-BUS. The ANN-BUS can be powered by an auxiliary power supply when the maximum number of ANN-BUS devices exceeds the Controls and Indicators ANN-BUS power requirements. See the FACP manual for more • AC Power information. • Alarm dn-7114:c•5/22/09—Page 1 of 2 ANN-BUS DEVICE ADDRESSING After calculating the total worst case current draw,the following Each ANN-BUS device requires a unique address(ID Number) table specifies the maximum distance the modules can be in order to communicate with the FACP.A maximum of 8 devices located from the FACP on a single wire run.The table ensures can be connected to the FACP ANN-BUS communication circuit. 6.0 volts of line drop maximum.In general,the wire length is lim See the FACP manual for more information. ited by resistance, but for heavier wire gauges, capacitance is the limiting factor. WIRE REQUIREMENTS:COMMUNICATIONS CIRCUIT These cases are marked in the chart with an asterisk(*). Maxi- The N-ANN-80 connects to the FACP ANN-BUS communica- mum length can never be more than 6,000 feet (1,800 m), tions circuit.To determine the type of wire and the maximum wir- regardless of gauge used. See table below. ing distance that can be used with FACP ANN BUS accessory WIRE REQUIREMENTS:POWER CIRCUIT modules,it is necessary to calculate the total worst case current draw for all modules on a single 4-conductor bus.The total worst • 14 to 18 AWG (0.75-2.08 mm2)wire for 24 VDC power cir- case current draw is calculated by adding the individual worst cuit is acceptable. case currents for each module. • All connections are power-limited and supervised. NOTE: For total worst case current draw on a single ANN-BUS • A maximum of eight N-ANN-80 modules may be connected refer to appropriate FACP manual. to this circuit. Communication Pair Wiring Distance: FACP to Last ANN-BUS Module Total Worst Case 22 Gauge 18 Gauge 16 Gauge 14 Gauge Current Draw(amps) 0.100 1,852 ft. 4,688 ft. *6,000 ft. *6,000 ft. 0.200 926 ft. 2,344 ft. 3,731 ft. 5,906 ft. 0.300 617 ft. 1,563 ft. 2,488 ft. 3,937 ft. 0.400 463 ft. 1,172 ft. 1,866 ft. 2,953 ft. 0.500 370 ft. 938 ft. 1,493 ft. 2,362 ft. 0.600 309 ft. 781 ft. 1,244 ft. 1,969 ft. 0.700 265 ft. 670 ft. 1,066 ft. 1,687 ft. 0.800 231 ft. 586 ft. 933 ft. 1,476 ft. 0.900 206 ft. 521 ft. 829 ft. 1,312 ft. 1.000(max.) 185 ft. 469 ft. 746 ft. 1,181 ft. WIRING CONFIGURATION ORDERING OPTIONS: The following figure illustrates the wiring between the FACP and N-ANN-80:Black 80 character LCD Annunciator. ANN-BUS devices. N-ANN-80-W:White,80 character LCD Annunciator. ANN-BUS and power ANN-SB8OKIT B: Black surface mount backbox with angled wiring are supervised wedge. and power-limited. ANN-SB8OKIT W: White surface mount backbox with angled ® 71 alt wedge. TBI 0000 4 3 2 1 ANN-BUS Device *MUM] 0 NFW-50 TB3 0 ft0 004.000 1 2 3 4 5 6 7 8 FACP Wiring to ANN-BUS Device 02009 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. ISo 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. E Ft-FIE F 1 E D We cannot cover all specific applications or anticipate all requirements. ENGINEER 8 MANNFAn1UNA All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—dn-7114:c•5/22/09 DSC From Tyco Security Products HSPA Universal Wireless Commercial Fire Alarm Communicator C300 3G4O1OCF ,, atur at Ice I1f 3rence' • SPA etvwork fei { 6 ,;!,1 Vieewn® }" a ns an IP 3G technology from DSC! r"k11 1 a est 5'4;4 serviceis The 3G4010CF connects the alarm protected premises within not more " control panel to the Cellular network than 24 hours of the failure. = and reports alarm signals directly to ha f a monitoring station receiver How it Works COdt f (Sur-Gard System I-IP/II/III/IV/5).The o .)forma •„ The 3G4010CF can be used as 3G4010CF uses the Cellular network � either a Sole Communicator or as a to ensure low-cost, high-speed and Backup Communicator.When being reliable alarm communications and is �t €ttt� C NC3 used as a Sole Communicator the o� compatible with control panels that r communicate using the Contact ID or 3G4010CF will replace the phone * 0; *, ' n SIA(300 baud)format. line connection on the panel and as soon as it detects that an alarm The 3G4010CF is compliant needs to be transmitted it will send "tet* nt00.1i;. or via with the latest requirements for the alarm across the Cellular network bort rr,: Communications Methods as per immediately.When being used as a ? Or UL864 and NFPA72 2010 and backup the communicator assesses e a ®ed by 2013 Editions. It can be used in the connection to the PSTN phone Fire Monitoring applications as a line, and only in the event of a phone °' " single communications technology, line failure will it send all alarm traffic flew . dnlcatt l z•us T� g 9Y. in which case any failure of the across the Cellular network to the dfi Ph9AmP , A communicationspath shall be monitoringstation. to ®"0rt on rptrtUtd' :. annunciated at the supervising station In instances where the control panel within 5 minutes(NFPA72 2010)or a Suri, �k does not support Contact ID or 1 hour(NFPA72 2013)of the failure, SIA(300 baud),the 3G4010CF has �r �(IW . oring or it can be used as part of a multiple state v€ �� •z. <'` communications technologies(for inputs pre-set to transmit fire alarm, g fire supervisory or system trouble. 40 1 '. . sU p rY Y 14 POw� � , example in conjunction with a DACT). + ,trait + e ' and 7 When used as a back-up provision Alarm signals are transmitted directly " ` shall be made to monitor the integrity without the need of a clearinghouse r 'r geabl -+ Ottery 9 tY 9 of each communication path and to the IP linecard of the monitoring failure of any communications station receiver(Sur-Gard®System • t path shall be annunciated at the I-IP/II/III/IV/5). n- z supervising station and at the communications Contact your DSC distributor. www.dsc.com 11-888-888-7838 DBD From Tyco Security Products Activating & Initializing the Unit Rate Plan Activating and initializing the 3G4010CF can be done using Cost-effective rate plans have been negotiated and are the automated telephone activation system(VRU), mobile available through authorized master resellers. Contact your interface or web-user interface provided by monitoring station or visit www.connect24.com to find a C24 Communications. No special tools are required. master reseller.When used as a sole communicator,the 3G4010CF requires use of the 4MB(NFPA72 2010)or Mobile Site for Easy Installation and 500kB(NFPA72 2013)rate plans to support the supervision Comprehensive Maintenance requirements. C24 Communications mobile site(m.connect24.com) Specifications makes the installation a simple process and offers intuitive trouble-shooting features, cutting down on time and cost Dimensions 11-1/2"x 10"x 3" allocated to maintenance. (290 mm x 254 mm x 75 mm) Input Voltage 120 VAC Current Draw 200 mA(standby) 400 mA(transmitting) Operating Environment 32°to 120° F(0°to 49°C) El Weight 12.8 lbs(5.8 kg) Optional Acessories gi gi z y rtes r peon UL Listing 0'9°7') Lff. tens6**114Sk..?... . use) The 3G4010CF is UL listed under File S4019, Listing guide GS-25ANT 25 ft extension antenna UOXX,as a sole or backup communicator for Commercial Fire (internal/external use) monitoring installations.When used as a sole communicator GS-50MT 50 ft extension antenna under NFPA72 2010 guidelines the 3G4010CF will send {tntemaVe nal use) its heartbeat once every 97 seconds ensuring that three heartbeats will be received at the supervising station within the 300 second window.When used as a sole communicator under NFPA72 2013 guidelines the 3G4010CF will send its heartbeat once every 5 minutes to monitor connectivity with the supervising station within the 1 hour window.When used as a backup communicator the 3G4010CF will monitor the other communication method(DACT)and send a daily test transmission to the supervising station. CSFM Listing The 3G4010CF has been approved by the California State Fire Marshal(CSFM)pursuant to Section 13144.1 of the California Health and Safety Code. Ordering Information: 3G4010CF-USA Universal Wireless Commercial Fire Alarm Communicator (U.S. Model/SIM Card Included) 8 0 communications For product information www.dsc.com Product specifications and availability subject to change without notice,Certain product names mentioned herein may be trade names and/or registered trademarks of other companies. ©2015 Tyco Security Products DN-6995:C••Al-320 NP-100(A) Series N OTI F 1 E R® Addressable Photoelectric Detectors for the FireWarden Series by Honeywell Addressable General The NP-100(A), NP-100T(A) and NP-100R(A) addressable, low-profile plug-in photoelectric detectors use a state-of-the- art photoelectric sensing chamber with communications to provide open area protection and are used exclusively with r=. NOTIFIER's FireWarden Series(FireWarden-100-2 and Fire- Warden-50) and Spartan (NSP-25) Addressable Fire Alarm Control Panels (FACPs). The NP-100T(A)adds thermal sen- I sors that will alarm at a fixed temperature of 135°F (57°C). Since these detectors are addressable, they will help emer- gency personnel quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage.Two LEDs on each sensor light to provide a local,visible sensor indication.Remote LED annunciator capa- bility is available as an optional accessory, PN RA100Z(A). The NP-100R(A)is a remote test capable detector for use with NP-100(A) in B210LP(A) Base DNR(A)/DNRW duct smoke detector housings. Features Applications SLC loop Use photoelectric detectors in life-safety applications to pro- • Two-wire loop connection. vide a broad range of fire-sensing capability, especially where • Unit uses base for wiring. smoldering fires are anticipated. Ionization detectors are often Addressing better than photoelectric detectors at sensing fast, flaming fires. • Addressable by device. • Rotary,decimal addressing:01 –99 with FireWarden-100-2 Construction and NSP 25,and 01 –50 with FireWarden 50. These detectors are constructed of off-white fire resistant plas- Architecture tic. NP-100(A) series plug-in, low-profile smoke detectors are • Unique single-source, dual-chamber design to respond designed to commercial standards and offer an attractive quickly and dependably to a broad range of fires. appearance. • Sleek,low-profile design. • Integral communications and built-in type identification. Installation • Built-in tamper-resistant feature. NP-100(A)series plug-in detectors use a detachable mounting • Removable cover and insect resistant screen for simple base to simplify installation,service and maintenance. field cleaning. Mount base(all base types)on an electrical backbox which is Operation at least 1.5"(3.81 cm)deep. For a chart of compatible junction • Withstands air velocities up to 4,000 feet-per-minute(20 m/ boxes,see DN-60054. sec.)without triggering a false alarm. NOTE:Because of the inherent supervision provided by the SLC • Factory at 1.5% nominal sensitivity for panel alarm loop, end-of-line resistors are not required. Wiring `T--taps" or threshold presetleset. branches are permitted for Style 4 (Class B) wiring. NP-100R(A) mounts in a DNR(A)/DNRW duct detector housing. • Visible LED"blinks"when the unit is addressed (communi- cating with the fire panel)and latches on in alarm. Operation Mechanicals Each NP-100(A) series detector uses one of 99 O possible • Sealed against back pressure. addresses on the FireWarden-100-2 and NSP-25,or one of 50 • Direct surface mounting or electrical box mounting. possible addresses on the FireWarden-50 Signaling Line Cir- • Mounts to: single gang box, 3.5" (8.89 cm) or 4.0" (10.16 cuit (SLC). It responds to regular polls from the system and cm)octagonal box,or 4.0"(10.16 cm)square electrical box reports its type and status. (using a plaster ring—included). The addressable photoelectric sensor in the NP-100(A)series Other system features has a unique unipolar chamberthat responds quickly and uni- formly to a broad range of smoke conditions. It can withstand • Fully coated circuit boards and superior RF/transient pro- wind gusts up to 4,000 feet-per-minute (20 m/sec.) without tection. sending an alarm level signal. Because of its unipolar cham- • 94-VO plastic flammability rating. ber, the NP-100(A) series is approximately two times more • Low standby current. responsive than most photoelectric sensors. This makes it a Options more stable detector. • Remote LED output connection, PN RA100Z(A). DN-6995:C•12/07/2011—Page 1 of 2 Detector Sensitivity Test NP-100RA:Same as NP-100R with ULC Listing for use with a Each detector can have its sensitivity tested (required per DNRA duct detector housing; B210LPA base included. NFPA 72,Chapter 14 on Inspection, Testing and Maintenance) INTELLIGENT BASES when installed/connected to a FireWarden-100-2 or FireWar- NOTE:"A"suffix indicates ULC Listed model. den-50 addressable fire alarm control panel.The results of the sensitivity test can be printed off the FireWarden-100-2 or Fire- NOTE:For details about intelligent bases and their mounting,see Warden-50 for record keeping. DN-60054. B210LP(A): Plug-in detector base (included); standard U.S. Specification flanged low-profile mounting base. Voltage range: 15—32 VDC(peak). B210LPBP:Bulk pack of B210LP;package contains 10. Standby current:300 pA 24 VDC. B501(A):Standard European flangeless mounting base. LED current:6.5 mA©24 VDC(latched"ON"). B501 BP: Bulk pack of B501;package contains 10. Air velocity:4,000 ft./min.(20 m/sec.)maximum. B200SR(A): Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Size:2.1"(5.33 cm)high;base determines diameter. Replaces 8501 BH series bases in retrofit applications. —B210LP(A):6.1"(15.5 cm)diameter. B224RB(A): Plug-in System Sensor relay base. Screw termi- -B501(A):4.1"(10.4 cm)diameter. nals:up to 14 AWG(2.0 mm2).Relay type:Form-C.Rating:2.0 —B200SR(A):6.875"(17.46 cm)diameter. A © 30 VDC resistive; 0.3 A 42 110 VDC inductive; 1.0 A —B224RB(A):6.2'(15.748 cm)diameter. 30 VDC inductive. Weight:3.6 oz.(102 g). B224BI(A): Plug-in System Sensor isolator detector base. Maximum 25 devices between isolator bases(see DN-6994). Operating temperature range: for NP-100(A):0°C to 49°C ACCESSORIES (32°F to 120°F);for NP-100T(A):0°C to 38°C(32°F to 100°F). NP-100R(A):installed in a DNR(A)/DNRW-20°C to 70°C(-4°F F110: Retrofit flange to convert B210LP(A) to match the to 158°F). B710LP(A) profile, or to convert older high-profile bases to Temperature:0°C—49°C(32°F—120°F). low profile. F110BP:Bulk pack of Fl 10;package contains 15. Relative humidity: 10%—93%,non-condensing. F210: Replacement flange for B210LP(A)base. Listings RA100Z(A): Remote LED annunciator.3—32 VDC. Mounts to Listings and approvals below apply to the NP-100(A), NP- a U.S. single-gang electrical box. For use with B501(A) and 100T(A), and NP-100R(A) detectors. In some cases, certain B210LP(A)bases only. modules may not be listed by certain approval agencies, or SMB600:Surface mounting kit tusng may be in process. Consult factory for latest listing sta M02-04-00:Test magnet. • UL Listed:S1115. M02-09-00:Test magnet with telescoping handle. • ULC Listed:S911. XR2B: Detector removal tool. Allows installation and/or CSFM:7272 0028:0231. removal of detector heads from bases in high ceiling applica- • tions. • MEA:243-02-E Vol.2. XP-4: Extension pole for XR2B. Comes in three 5-foot(1.524 • Maryland State Fire Marshal:permit 2173. m)sections. • FM approved. T55-127-010:Detector removal tool without pole. Product Line Information BCK-200B:Black detector covers for use with NP-100(A)only; box of 10. NOTE:"A"suffix indicates ULC Listed model. WCK-200B: White detector covers for use with NP-100(A) x F.fi , . m m only;box of 10. NP-100A:Sames as NP-100 with ULC Listing; B210LPA base included. NP-100T: Same as NP-100 but with thermal element; B210LP base included. NP-100TA: Same as NP-100T with ULC Listing; B210LPA base included. NP-100R: Remote test capable addressable photoelectric NOTIFIER® and FireWarden® are registered trademarks of Honeywell detector for use with a DNRA/DNRW duct detector housing; Ic. Oti tioAlnarignts reserved. Unauthorized use of this document is strictly B210LP base included. prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. CERTF 1 E R We cannot cover all specific applications or anticipate all requirements. NINON&HAUNTING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—DN-6995:C•12/07/2011 DN-6997:D•Al-320 NH-100(A) Series NOTIFIER Intelligent Addressable Thermal Detectors for FireWarden Series by Honeywell Addressable General The NOTIFIER NH-100(A) Series thermal detectors are addressable sensors that use a state-of-the-art thermistor sensing circuit for fast response.These sensors provide open- area protection and are intended for use with FireWarden • Series (FireWarden-100-2 and FireWarden-50) and Spartan (NSP-25)addressable Fire Alarm Control Panels(FACPs). The NH-100(A) and NH-100R(A) sensors provide fixed tem- perature alarm detection at 135°F (57°C). The NH-100R(A) sensor also responds to rate-of-rise conditions of greater than 15°F(8.3°C)per minute.The NH-100H(A)is a fixed high-tem- perature detector that activates at 190°F (88°C). These ther- mal detectors provide addressable property protection in a variety of applications. Two LEDs on each sensor light to provide a local,visible sen- NH-100(A) in B210LP(A) Base sen- sor indication. Remote LED annunciator capability is available using an optional accessory,the RA100Z. • Low standby current. • 94-5V plastic flammability rating. Features Options: SLC loop: • Remote LED output connection to optional RA100Z remote • Two-wire SLC loop connection. LED annunciator. • Unit uses base for wiring. • Flanged surface mounting kit. Addressing: Installation • Addressable by device. NH-100(A) Series plug-in intelligent thermal detectors use a • Rotary, decimal addressing: 01 —99 with FireWarden-100- detachable base to simplify installation, service and mainte- 2,NSP-25,01 —50 with FireWarden-50. nance. Installation instructions are shipped with each detector. Architecture: Mount base(all base types)on an electrical backbox which is • Sleek,low-profile,stylish design. at least 1.5"(3.81 cm)deep. For a chart of compatible junction • State-of-the-art thermistor technology for fast response. boxes,see DN-60054. • Integral communications and built-in device-type identifica- NOTE:Because of the inherent supervision provided by the SLC tion. loop, end-of-line resistors are not required. Wiring `T-taps" or • Built-in tamper resistant feature. branches are permitted for Style 4(Class"B")wiring only. • Built-in functional test switch activated by external magnet. Applications Operation: • Factory preset at 135°F(57°C)for the NH-100(A)and NH- Use thermal detectors for protection of property. 100R(A); 190°F(88°C)for the NH-100H(A). • Rate-of-rise triggers at 15°F(8.3°C)per minute for the NH- Construction 100R(A). These detectors are constructed of off-white fire-resistant • 360°-field viewing angle of the visual alarm indicators (two plastic. The NH-100(A) Series plug-in intelligent thermal bicolor LEDs). LEDs blink red in Normal condition and turn detectors are designed to commercial standards and offer an on steady red in Alarm. attractive appearance. • Visible LEDs"blink"every time the unit is addressed. Operation Mechanicals: • Sealed against back pressure. Each NH-100(A)Series detector uses one of 99(FireWarden- 100-2, NSP-25)or 50(FireWarden-50)possible addresses on • SEMS screws for wiring of the separate base. a control panel SLC loop. It responds to regular polls from the • Designed for direct-surface or electrical-box mounting. control panel and reports its type and the status.If it receives a • Plugs into separate base for ease of installation and main- test command from the panel(or a local magnet test), it stimu- tenance. lates its electronics and reports an alarm. It blinks its LEDs • Separate base allows interchange of photoelectric, ioniza when polled and turns the LEDs on when commanded by the tion and thermal sensors. panel.The NH-100(A)Series offers features and performance that represent the latest in thermal detector technology. Other system features: • Remote test feature from the panel. • Walk test with address display. DN-6997:D•5/17/13—Page 1 of 2 Spefications INTELLIGENT BASES Size:2.1"(5.3 cm)high; base determines diameter. NOTE:"A"suffix indicates ULC Listed model. —B210LP(A):6.1'(15.5 cm)diameter. NOTE:For details about intelligent bases and their mounting,see DN-60054. —B501(A):4.1"(10.4 cm)diameter. —B200SR(A):6.875"(17.46 cm)diameter. B210LP(A): Plug-in detector base (included); standard U.S. flanged low-profile mounting base. —B224RB(A):6.2"(15.748 cm)diameter. B210LPBP:Bulk pack of B210LP;package contains 10. Shipping weight:4.8 oz.(137 g). B501(A):Standard European flangeless mounting base. Installation temperature: B501BP: Bulk pack of B501;package contains 10. —NH 100(A), NH 100R(A):—4°F to 100°F(-20°C to 38°C). B200SR(A): Intelligent sounder base capable of producing —NH-100H(A):—4°F to 150°F(-20°C to 66°C). sound output with ANSI Temporal 3 or continuous tone. Humidity range: 10% to 93% relative humidity (noncon- Replaces B501 BH series bases in retrofit applications. densing). B224RB(A): Plug-in System Sensor relay base. Screw termi- Voltage range: 15 to 32 VDC peak. nals:up to 14 AWG(2.0 mm2).Relay type:Form-C.Rating:2.0 Standby current: 300 pA CP 24 VDC (one communication A © 30 VDC resistive; 0.3 A CO 110 VDC inductive; 1.0 A 4 every five seconds with LED blink enabled). 30 VDC inductive. LED current:6.5 mA 42 24 VDC. B224B1(A): Plug-in System Sensor isolator detector base. Maximum 25 devices between isolator bases(see DN-6994). Mounting: B210LP(A) flanged base, included. See "Product Line Information: Intelligent Bases"if using a different base. ACCESSORIES Fixed-temperature setpoint: 135°F (57°C) for the NH-100 F110: Retrofit flange to convert B210LP(A) to match the and NH-100R(A)(A); 190°F(88°C)for the NH-100H(A). B710LP(A) profile, or to convert older high-profile bases to Rate-of-rise detection:responds to greater than 15°F(8.3°C) low profile. per minute. F110BP:Bulk pack of F110;package contains 15. F210: Replacement flange for B210LP(A)base. Listings and Approvals RA100Z(A): Remote LED annunciator.3—32 VDC.Mounts to Listings and approvals below apply to the NH-100(A) Series a U.S. single-gang electrical box. For use with B501(A) and detectors. In some cases, certain modules may not be listed B210LP(A)bases only. by certain approval agencies, or listing may be in process. SMB600:Surface mounting kit Consult factory for latest listing status. • UL Listed:S747. M02-04-00:Test magnet. • ULC Listed:S747. M02-09-00:Test magnet with telescoping handle. • CSFM:7270-0028:0234. XR2B: Detector removal tool. Allows installation and/or • MEA:387-02-E Vol. II. removal of detector heads from bases in high ceiling applica- tions. • FM approved. XP-4: Extension pole for XR2B. Comes in three 5-foot(1.524 Product Line Information m)sections. T55-127-010:Detector removal tool without pole. NOTE:"A"suffix indicates ULC Listed model. NH-100: Intelligent thermal sensor; 135° F (57° C); B210LP base included. NH-100A: Same as NH-100 but with ULC Listing; B210LPA base included. NH-100R: Same as NH-100 with rate-of-rise feature; B210LP base included. NH-100RA:Same as NH-100R but with ULC Listing;B210LPA base included. NH-100H: Intelligent fixed high-temperature thermal detector; 190°F(88°C); B210LP base included. NH-100HA:Same as NH-100H but with ULC Listing;B210LPA base included. NOTIFIER® and FireWarden® are registered trademarks of Honeywell International Inc. ®2013. All rights reserved. Unauthorized use of this document is strictly prohibited. ASO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. CERT 1 F E D We cannot cover all specific applications or anticipate all requirements. ENGINEERING i MiNIHIC1111N6 All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—DN-6997:D•5/17/13 Monitor Modules DN-6999:C NMM-100(A), NMM-100P(A), NOTIFIER® NZM-100(A), and NDM-100(A) for FireWarden Series Panels by Honeywell Intelligent Addressable Devices General Four different monitor modules are available for Notifier's Fire- Warden Series intelligent control panels for a variety of appli- cations. Monitor modules supervise a circuit of dry-contact e t input devices, such as conventional heat detectors and pull stations, or monitor andp ower a circuit of two-wire smoke a _ detectors(NZM-100(A)). NMM-100(A)is a standard-sized module(typically mounts to a 4" [10.16 cm] square box) that supervises either a Style D (Class A) or Style B (Class B) circuit of dry-contact input devices. NMM-100P(A) is a miniature monitor module a mere 1.3" (3.302 cm) H x 2.75" (6.985 cm) W x 0.5" (1.270 cm) D that supervises a Style B (Class B) circuit of dry-contact input ,.. devices. Its compact design allows the NMM-100P(A) to be mounted in a single-gang box behind the device it monitors. NZM-100(A) is a standard-sized module that monitors and supervises compatible two-wire,24 volt,smoke detectors on a Style D(Class A) or Style B(Class B)circuit. NDM-100(A) is a standard-sized dual monitor module that NMM-100(A)(Type H) monitors and supervises two independent two-wire Style B (Class B) dry-contact initiating device circuits (IDCs) at two separate,consecutive addresses in intelligent,two-wire systems. NMM-100(A) OPERATION Each NMM-100(A) uses one of the available module NMM-100(A) Monitor Module addresses on an SLC loop. It responds to regular polls from • Built-in type identification automatically identifies this device the control panel and reports its type and the status(open/nor- as a monitor module to the control panel. mal/short)of its Initiating Device Circuit(IDC). A flashing LED indicates that the module is in communication with the control • Powered directly by two wire SLC loop.No additional power panel. The LED latches steady on alarm (subject to current required. limitations on the loop). • High noise(EMF/RFI)immunity. • SEMS screws with clamping plates for ease of wiring. NMM-100(A) SPECIFICATIONS • Direct Decade entry of address: 01 —99 on FireWarden- Nominal operating voltage: 15 to 32 VDC. 100-2,01 —50 on FireWarden-50. Maximum current draw:5.0 mA(LED on). • LED flashes during normal operation and latches on steady Average operating current: 350 pA (LED flashing), 1 com- to indicate alarm. munication every 5 seconds,47k EOL. The NMM-100(A)Monitor Module is intended for use in intelli- Maximum IDC wiring resistance:40 ohms. gent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro EOL resistance:47K ohms. vides either a two-wire or four-wire fault-tolerant Initiating Temperature range:32°F to 120°F(0°C to 49°C). Device Circuit (IDC)for normally-open-contact fire alarm and Humidity range: 10%to 93%noncondensing. supervisory devices. The module has a panel-controlled LED indicator. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x NMM-100(A)APPLICATIONS 2.125"(5.398 cm)deep box. Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally- open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B(Class B)or Style D(Class A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. DN-6999:C•10/06/2010—Page 1 of 4 F �$ � � Dimensions: 1.3" (3.302 cm) high x 2.75" (6.985 cm)wide x • Built-in type identification automatically identifies this device 0.65"(1.651 cm)deep. as a monitor module to the panel. Wire length:6"(15.24 cm)minimum. • Powered directly by two-wire SLC loop.No additional power required. NZM-100(A) Interface Module • High noise(EMF/RFI)immunity. • Supports compatible two-wire smoke detectors. • Tinned,stripped leads for ease of wiring. • Supervises IDC wiring and connection of external power • Direct Decade entry of address: 01 — 99 on FireWarden- source. 100-2,01 —50 on FireWarden-50. • High noise(EMF/RFI)immunity. • SEMS screws with clamping plates for ease of wiring. 1415 0 1 ADDRESS 0 1 • Direct Decade entry of address:, 01 —99 on FireWarden- 1:S2 � ^, 2 100-2,01 —50 on FireWarden-50. �� 4 LOOP 04 • LED flashes during normal operation. • LED latches steady to indicate alarm on command from 6 5 9 6 5 control panel. 8 7TENS ONES The NZM-100(A)Interface Module is intended for use in intelli- n n n n gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors.It transmits the status(nor- 0 LU p mal,open,or alarm)of one full zone of conventional detectors LU U back to the control panel. All two-wire detectors being 0monk UCO tored must be UL compatible with the module. NZM-100(A) APPLICATIONS Use the NZM-100(A) to monitor a zone of two-wire smoke I I I I detectors. The monitored circuit may be wired as an NFPA Style B(Class B)or Style D(Class A)Initiating Device Circuit. The NMM-100P(A) Mini Monitor Module can be installed in a A 3.9 K ohm End-of-Line Resistor (provided) terminates the single-gang junction directly behind the monitored unit. Its end of the Style B or D (class B or A) circuit(maximum IDC small size and light weight allow it to be installed without rigid loop resistance is 25 ohms). Install ELR across terminals 8 mounting.The NMM-100P(A)is intended for use in intelligent, and 9 for Style D application. two-wire systems where the individual address of each module is selected using rotary switches. It provides a two-wire initiat- NZM-100(A)OPERATION ing device circuit for normally-open-contact fire alarm and Each NZM-100(A) uses one of the available module security devices. NMM-100P(A) addresses on an SLC loop. It responds to regular polls from NM/14-100P(A)APPLICATIONS the control panel and reports its type and the status(open/nor- mal/short)of its Initiating Device Circuit(IDC). A flashing LED Use to monitor a single device or a zone of four-wire smoke indicates that the module is in communication with the control detectors,manual fire alarm pull stations,waterflow devices,or panel. The LED latches steady on alarm (subject to current other normally-open dry-contact devices. May also be used to limitations on the loop). monitor normally-open supervisory devices with special super- visory indication at the control panel. Monitored circuit/device NZM-100(A)SPECIFICATIONS is wired as an NFPA Style B(Class B)Initiating Device Circuit. Nominal operating voltage: 15 to 32 VDC. Au47K ohm End-of-Line Resistor(provided)terminates the cir- Maximum current draw:5.1 mA(LED on). NMM-100P(A)OPERATION Maximum IDC wiring resistance:25 ohms. Each NMM-100P(A) uses one of the available module Average operating current: 300 pA, 1 communication and 1 addresses on an SLC loop. It responds to regular polls from LED flash every 5 seconds,3.9k eol. the control panel and reports its type and the status(open/nor- EOL resistance:3.9K ohms. mal/short)of its Initiating Device Circuit(IDC). External supply voltage (between Terminals T3 and T4): NMM-100P(A) SPECIFICATIONS DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum.Current:90 mA per module maximum. Nominal operating voltage: 15 to 32 VDC. Temperature range:32°F to 120°F(0°C to 49°C). Average operating current: 350 pA, 1 communication every Humidity range: 10%to 93%noncondensing. 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Shorted). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x Maximum IDC wiring resistance:40 ohms. 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125"(5.398 cm)deep box. Maximum IDC Voltage: 11 Volts. Maximum IDC Current:400 pA. EOL resistance:47K ohms. Temperature range:32°F to 120°F(0°C to 49°C). Humidity range: 10%to 93%noncondensing. Page 2 of 4—DN-6999:C•10/06/2010 NDM-100(A) Dual Monitor Module • MEA: 72-01-E Vol. 2 (NMM-100, NMM-100P, NZM-100); The NDM-100(A) Dual Monitor Module is intended for use in 227-03-E Vol.3(NDM-100) intelligent, two-wire systems. It provides two independent two- wire initiating device circuits(IDCs)at two separate,consecutive Product Line Information addresses. It is capable of monitoring normally open contact fire NOTE:"A"suffix indicates ULC-listed model. alarm and supervisory devices.The module has a single A panel NMM-100 : Monitor module. controlled LED. ( ) NOTE: The NDM-100(A)provides two Style B(Class B)IDC cir- NMM-100P(A):Monitor module,miniature. cults ONLY. Style D(Class A)IDC circuits are NOT supported in NZM-100(A):Monitor module,two-wire detectors. any application. NDM-100(A): Monitor module,dual,two independent Class B NDM-100(A)SPECIFICATIONS circuits. Normal operating voltage range: 15 to 32 VDC. SMB500:Optional surface-mount backbox. Maximum current draw:6.4 mA(LED on). NOTE: See installation instructions and refer to the SLC Wiring Average operating current:750 pA(LED flashing). Manual,PN 52304. Maximum IDC wiring resistance:1,500 ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current:240 pA EOL resistance:47K ohms. Maximum SLC Wiring resistance:40 Ohms. Temperature range:32°to 120°F(0°to 49°C). Humidity range: 10%to 93%(non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 2.125"(5.398 cm)deep. NDM-100(A) AUTOMATIC ADDRESSING The NDM-100(A) automatically assigns itself to two address- able points, starting with the original address. For example, if the NDM-100(A) is set to address "26", then it will automati- cally assign itself to addresses"26"and"27". NOTE: "Ones"addresses on the NDM-100(A)are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address,and terminals 8 and 9 use the second address. QCAUTION: Avoid duplicating addresses on the system. Installation NMM-100(A), NZM-100(A), and NDM-100(A) modules mount directly to a standard 4"(10.16 cm)square,2.125"(5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and installa- tion instructions are provided with each module. All wiring must conform to applicable local codes,ordinances,and regu- lations. These modules are intended for power-limited wiring only. The NMM-100P(A) module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordi- nances,and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. • UL:S635 • ULC:S635 • FM Approved • CSFM: 7300-0028:0230 (NMM-100, NMM-100P, NZM- 100);7300-0028:0237(NDM-100) DN-6999:C•10/06/2010—Page 3 of 4 dn-60383:A2 NC-100R(A) NOT 1 F 1 E R® Relay Module for FireWarden Series Panels by Honeywell Addressable General The NC-100R(A) Addressable Relay Module provides NOTI- FIER's FireWarden Series intelligent control panels with two isolated sets of Form-C dry-contact outputs for activating a variety of auxiliary devices,such as fans,dampers,door hold41, % NI) - ers,control equipment, etc.Addressability allows the dry con- tact to be activated, either manually or through panel programming,on a select basis. Features • Built-in type identification automatically identifies these devices to the control panel. • Internal circuitry and relay powered directly by two-wire SLC loop. • Integral LED "blinks" green each time a communication is received from the control panel and turns on in steady when • activated. 41Ik q111 41Pp • High noise immunity(EMF/RFI). • Wide viewing angle of LED. • SEMS screws with clamping plates for wiring ease. NC-100R(A) • Direct Decade entry of address: 01 —99 with the FireWar- den-100-2(C)and 01 —50 with the FireWarden-50(C). Applications The NC-100R(A)may be programmed to operate dry contacts Specifications for door holders,Air Handling Unit shutdown,etc.,and to reset Normal operating voltage: 15 to 32 VDC. four-wire smoke detector power. Maximum SLC current draw: 6.5 mA(LED). Construction Average operating current: 230 pA direct poll (CLIP mode), • The face plate is made of off-white heat-resistant plastic. 255 pA group poll with LED flashing. • Controls include two rotary switches for direct-dial entry of EOL resistance: not used. address setting. Temperature range: 32°F to 120°F(0°C to 49°C). • The NC-100R(A) provides two Form-C dry contacts that Humidity range: 10%to 93%non-condensing. switch together. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x Operation 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125"(5.398 mm)deep box. Each NC-100R(A)uses one of the addresses on a SLC loop.It responds to regular polls from the control panel and reports its Relay Contact Ratings type and status. The LED blinks with each poll received. On command,it activates its internal relay. Maximum Current Load Description Application Voltage Rating Rotary switches set a unique address for each module. The g g address may be set before or after mounting. The built-in Resistive Non-Coded 30 VDC 3.0 A TYPE CODE(not settable)will identify the module to the con- trol panel. Resistive Coded 30 VDC 2.0 A Resistive Non-Coded 110 VDC 0.9 A Resistive Non-Coded 125 VAC 0.9 A Inductive(L/R=5ms) Coded 30 VDC 0.5 A Inductive(L/R=2ms) Coded 30 VDC 1.0 A Inductive(PF=0.35) Non-Coded 125 VAC 0.5 A dn-60383:A2•06/17/10—Page 1 of 2 Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. • UUULC Listed:S635. • CSFM approved:file 7300-0028:230. • FM approved. • MEA approved:file 72-01-E,Vol.2. Product Line Information NC-100R: Intelligent addressable relay module. NC-100RA: Intelligent addressable relay module,ULC listed model. SMB500:Optional surface-mount backbox. NOTE: For installation instructions, see document 156-2593-001 and refer to the SLC Wiring Manual,document 52304. NOTIFIER®is a registered trademark of Honeywell International Inc. 02010 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. C E R T F E D We cannot cover all specific applications or anticipate all requirements. "'* EMOIMf3Il6 i MMIFACDUNC All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—dn-60383:A2•06/17/10 DN-7001:D•A1-380 NOT-BG 12LX NOTIFIER® Addressable Manual Pull Station by Honeywell Intelligent/Addressable Devices General The Notifier NOT-BG12LX is a state-of-the-art, dual-action a> (i.e., requires two motions to activate the station) pull station that includes an addressable interface for FireWarden series intelligent control panels,and the NSP-25 panel. Because the NOT-BG12LX is addressable,the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. Features • Maintenance personnel can open station for inspection and address setting without causing an alarm condition. • Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. • Handle latches in down position and the word"ACTIVATED" appears to clearly indicate the station has been operated. • Captive screw terminals wire-ready for easy connection to SLC loop(accepts up to 12 AWG/3.25 mm2 wire). • Can be surface mounted (with SB-10 or SB-I/O) or semi flush mounted. Semi-flush mount to a standard single- gang,double-gang,or 4"(10.16 cm)square electrical box. • Smooth dual-action design. The NOT-BG12LX • Meets ADAAG controls and operating mechanisms guide- Addressable Manual Pull Station lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. maximum activation force. • Highly visible. The BG12TR is usually needed for semi-flush mounting with 4" • Attractive shape and textured finish. (10.16 cm)or double-gang boxes(not with single-gang boxes). • Key reset. Operation • Includes Braille text on station handle. • Optional trim ring(BG12TR). Pushing in,then pulling down on the handle causes it to latch in the down/activated position. Once latched,the word"ACTI- • Meets UL 38, Standard for Manually Actuated Signaling VATED" (in bright yellow) appears at the top of the handle, Boxes. while a portion of the handle protrudes from the bottom of the station.To reset the station, simply unlock the station with the Construction key and pull the door open.This action resets the handle;clos- Shell, door, and handle are molded of durable polycarbonate ing the door automatically resets the switch. material with a textured finish. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual Specifications switch.Two rotary decimal switches allow address settings (1 —99 on NFW2-100/NFW2-100C, 1 —50 for NFW-50/NFW- • Shipping Weight:9.6 oz.(272.15 g) 50C). • Normal operating voltage:24 VDC. • Maximum SLC loop voltage:28.0 VDC. Architectural/Engineering • Maximum SLC standby current:375 NA. Specifications • Maximum SLC alarm current:5 mA. Manual Fire Alarm Stations shall be non-coded, with a key- • Temperature Range:32°F to 120°F(0°C to 49°C) operated reset lock in order that they may be tested, and so • Relative Humidity: 10%to 93%(noncondensing) designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key.An operated sta- • For use indoors in a dry location tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of Installation red-colored polycarbonate material with clearly visible operat- The NOT-BG12LX will mount semi-flush into a single-gang, ing instructions provided on the cover. The word FIRE shall double-gang,or standard 4"(10.16 cm)square electrical outlet appear on the front of the stations in white letters, 1.00 inches box, or will surface mount to the model SB-10 or SB-I/O sur- (2.54 cm) or larger. Stations shall be suitable for surface face backbox. If the NOT-BG12LX is being semi flush mounting on matching backbox SB-10 or SB-I/O;or semi-flush mounted, then the optional trim ring (BG12TR) may be used. mounting on a standard single gang, double gang, or 4'(10.16 cm) square electrical box, and shall be installed DN-7001:D•4/13/2012—Page 1 of 2 NEL within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel,send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. Product Line Information NOT BG12LX: Dual-action addressable pull station. Includes key locking feature. (Listed for Canadian and non-Canadian applications.) SB-10:Surface backbox;metal. SB-UO:Surface backbox;plastic. BG12TR:Optional trim ring. 17021:Keys,set of two. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess.Consult factory for latest listing status. • UL/ULC Listed: S692(listed for Canadian and non-Cana- dian applications). • MEA:67-02-E Vol. IV. • CSFM:7150-0028:0199. • FM Approved. Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. NOTIFIER®is a registered trademark of Honeywell International Inc. ©2012 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. C E R T F I E 6 We cannot cover all specific applications or anticipate all requirements. MEM i MAMMMTIMMI All specifications are subject to change without notice. DUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—DN-7001:D•4/13/2012