Loading...
Report (56) 2 SUPERVISORY SIGNAL INITIATING DEVICES AND CIRCUIT INFORMATION QTY OF CIRCUIT STYLE BUILDING TEMP. SITE WATER TEMP. SITE WATER LEVEL FIRE PUMP POWER FIRE PUMP RUNNING FIRE PUMP AUTO POSITION FIRE PUMP OR PUMP CONTROLLER FIRE PUMP RUNNING GENERATOR IN AUTO POSITION GENERATOR OR CONTROLLER TBL SWITCH TRANSFER GENERATOR ENGINE RUNNING OTHER: SIGNALING LINE CIRCUITS Quantity and style(See NFPA 72,Table 3-6)of signaling line circuits connected to system: Quantity 1 Style(s)B SYSTEM POWER SUPPLIES a.Primary(Main): Nominal Voltage 120 Amps 20 Over-current Protection: Type BREAKER Amps 20 Location(Panel Number): L2 CRKT 8 Disconnecting Means Location:ELECT RM BEHIND FACP RM b. Secondary(Standby): Storage Battery:2 Amp-Hr.Rating 7 Calculated capacity to operate system,in hours: ®24 ❑60 TYPE BATTERY ❑Dry Cell ❑Nickel-Cadmium ® Sealed Lead-Acid ❑Lead-Acid ❑Other(Specify) c.Emergency or standby system used as a backup to primary power supply,instead of using a secondary power supply consist of one of the following: ®Emergency system described in NFPA 70,Article 700 Legally required standby described in NFPA 70,Article 701 ❑Optional standby system described in NFPA 70,Article 702,which also meets the performance requirements of Article 700 or 701. PRIOR TO ANY TESTING NOTIFICATIONS ARE MADE: YES NO WHO TIME MONITORING ENTITY ® ❑ CSM 7AM BUILDING OCCUPANTS ® ❑ BUILDING MANAGEMENT ® ❑ CHRIS MORRIS 7AM OTHER(SPECIFY) ❑ ❑ AHJ(NOTIFIED)OF ANY IMPAIRMENTS ❑ ❑ t 3 SYSTEM TESTS AND INSPECTIONS TYPE VISUAL FUNCTIONAL COMMENTS CONTROL PANEL INTERFACE EQ. ❑ ❑ LAMPS/LEDS FUSES PRIMARY POWER SUPPLY TROUBLE SIGNALS DISCONNECT SWITCHES GROUND FAULT MONITORING El E SECONDARY POWER TYPE VISUAL FUNCTIONAL COMMENTS BATTERY CONDITION LOAD VOLTAGE DISCHARGE TEST CHARGER TEST SPECIFIC GRAVITY ❑ ❑ TRANSIENT SUPPRESSORS ❑ REMOTE ANNUNCIATORS V ® FRONT DOOR NOTIFICATION APPLIANCES AUDIBLE VISUAL SPEAKERS ❑ ❑ VOICE CLARITY ❑ ❑ INITIATING AND SUPERVISORY DEVICE TESTS AND INSPECTIONS DEVICE VISUAL FUNCTIONAL LOC.&S/N TYPE CHECK TEST PASS FAIL 011-1ST FLR ELECT RM SMOKE E ® ® ❑ 012-1ST FLR ATM RM SMOKE ® E ® ❑ 013-1ST FLR VAULT SMOKE E E E ❑ 014-1ST FLR STORAGE RM SMOKE ® ® ® ❑ 015- 1ST FLR BREAK RM SMOKE ® ® ® ❑ 021-2ND FLR ELECT RM SMOKE ® ® E ❑ 022-2ND FLR FACP RM SMOKE E E ® ❑ 023-2ND FLR W.BRK RM HEAT ® ® .1 ❑ 024-2ND FLR E.BRK RM HEAT ® ® ® ❑ 031-3RD FLR ELECT RM SMOKE ® ® ® ❑ 032-3RD FLR BRK RM HEAT ® ® ® ❑ 033-3RD FLR SERVER RM SMOKE ® ® ® ❑ 036-1ST FLR N STAIR PULL ® ® ® ❑ 037-1ST FLR MAIN ENT PULL ® ® ® ❑ 038-1ST FLR S STAIR PULL ® ® ® ❑ 039-2ND FLR N STAIR PULL ® ® ® ❑ 040-2ND FLR S STAIR PULL ® ® ® ❑ oor L"-) O 11R° r r - c4 i 1?--1 � b rr4r14 moo c d ❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑O❑❑❑❑❑❑❑❑❑❑❑®® E � r � ❑❑❑❑❑OO❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑O❑❑❑❑❑❑❑❑❑ 111EE roy O ❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑OO❑❑❑❑❑❑❑O❑❑❑❑❑❑❑❑❑❑❑❑❑❑EE z - ❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑O❑❑❑❑❑❑O❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑r z ¢❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑ ° H � w A C D400000000000001=100000000000000000000000000000000U HIV O 0 z a00H Z PF❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑ A U `C "° w v' A ci) w ril 4 W❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑ w A A pw Fla Rdzw Qa A w cA Q01 a z4A ° Hi n Oa U oW k 6 ON/OFF PREMISES MONITORING: YES NO TIME COMMENTS ALARM SIGNAL ® ❑ ALARM RESTORAL ® ❑ TROUBLE SIGNAL ® ❑ SUPERVISORY SIGNAL ® ❑ SUPERVISORY RESTORAL ® ❑ NOTIFICATIONS THAT TESTING IS COMPLETE: YES NO TIME WHO BUILDING MANAGEMENT ® ❑ MONITORING AGENCY ® ❑ BUILDING OCCUPANTS ® ❑ OTHER(SPECIFY) ❑ ❑ COMMENTS: SYSTEM RESTORED TO NORMAL OPERATION: YES NO DATE TIME 0 0 06-10-2016 12:00 TESTING WAS PERFORMED IN ACCORDANCE WITH APPLICABLE NFPA STANDARDS. NAME OF INSPECTOR: DATE: TIME: SIGNATURE: OWNERS REPRESENTATIVE: DATE: TIME: SIGNATURE: WITNESSED BY THE AUTHORITY HAVING JURISDICTION YES ❑NO❑ NAME OF AUTHORITY HAVING JURISDICTION: SIGNATURE: DATE: TIME: Stoner Protective Systems 1904 S.E.Ochoco St Milwaukie,OR 97222 (503)462-5203 Fax(503)659-2824 Watts(800)548-2701 CCB#44823