Report (40) Interstate and Owner ate committed to acting promptly so that mal ledks are net a source of potential Interior organic growth.Owner will make periodic►nspectione for signs of water intrusion and act promptly including prompt notice to Interstate if Owner believes there are roof teaks,to eremite Certain.Upon receiving notice,interstate will make roof repairs.The Owner is responsible for monitoring any leak areas for indoor air quality.Interstate is not responsible for indoor air quality.Owner shell hold harmless and indemnity Intestate from claims due to indoor air quality and resulting from a failure by Ownerto maintain the building in a manner to avoid organic growth.Customer agrees to indemnify and hold harmless Interstate from claims brought by tenants andror third partes ending from Organic growth. Where the terns and provisions of this agreement shall be in oOnlGct Wigs the terms Of any separate Contract proposal or order,the parties agree that the terms end provision$of Mb agreement shah be controlling. LIMITATION Qt{AC7IONS:THE PARTIES HERETO AGREE THAT A LAWSUIT FILED TO ENFORCE THIS CONTRACTOR RESOLVE ANY DISPUTE RELATED TO THIS CONTRACT MUST BE COMMENCED WITHIN FIVE(S)YEARS FROM THE DATE OF FINAL BILLING OR FROM THE DATE INTERSTATE ROOFING LAST PERFORMS WORK UNDER THIS CONTRACT,WHICHEVER IS EARLIER,OR BE FOREVER BARRED.NOT WITHSTANDING THE ABOVE,ANY CLAIM ALLEGING NEGLIGENCE MUST BE COMMENCED WITHIN ONE(1)YEAR OF DISCOVERY OF'IHE NEGLIGENCE,BUT NOT MORE THAN PIVE(5)YEARS FROM THE DATE OF FINAL BILLING OR FROM THE DATE INTERSTATE ROOFING LAST PERFORMED WORK UNDER THIS CONTRACT,WHICHEVER iS EARLIER,OR BE FOREVER BARRED.THIS PROVISION APPLIES INSTEAD OF ANT LJMITATIDNS PERIOD OTHERWISE PROVIDED BY LAW. Arbitration RequiredlMedlatlon First Option.Any dispute or claim that arises out of or that relates to thin agreement,or to the interpretation or breach thereof,shall be resolved by arbitration in accordance with the then effective arbitration rules of Arbitration Service of Porflaod.Int.by Nino a claim hl accOrdance with the filing Rh*of ASP,and Judgment upon the award rendered pursuant to such arbitration may be entered in any court having jurisdiction thereof.The owner,the contractor, and all subcontractors,materiel suppliers,engineers,architects,designers,construction lenders,bonding companies,and all other parties concerned with or involved in the performance of the contract are bound,each to the other,by this arbitration clause,provided such party has signed this contract,or hes signed a contract that incorporates this cantract by reference,or signs any other agreement to be bound by this arbitration clause.The arbitrator selected must be a construction taw attorney with not leas then ten years in practice,and the parties stipulate to only one arbitrator,regardless of size of the amount in controversy. This arbitration clause shag not preclude any party from Sing a statutory oonstreCeee lien or from commendng Suit to foreclose sun's lien,but the taredsure suit shall IX Stayed tntil the rendering of the arbitration award,which award shall be binding in such foradosure suit as to all matters determined in arbitration,and the lien may then be foreclosed to the extent permitted by law.The parties acknowledge that mediation usually helps parties to themselves settle their dispute.Therefore,any party may propose mediation whenever appropriate through one of the above named organizations or any other medisdon process or mediator as the paries may agree upon, The arbitration will be conducted in the hi-county area in or around Portland,Oregon. Attorney's Fees.In the event suit or action is brought,or en arbitration proceeding is initiated,to enforce or interpret arty of the provisions of this agreement,or that is based thereon,the prevailing patty shall be entitled to reasonable attorney's fees and consultant fees in connection therewith.The determination of who is the prevailing party and the amount of reasonable attorney's leas to be paid to the prevailing patty shag be decided by the arbitrator(a)(with respect to attorney's fees incurred prior to and during the arbitration proeeedings)and by the court or courts,including any appellate court,in which such matter is tried,heard,or deckled, including a court that hears a request to compel or enjoin arbitration or that hears any exceptions or otgactions to,Or menet*to modify Or vacate,an arbitration award submitted to it for confir madon as a judgment(with respect to attorney's fees incurred in such proceedings). At work to be completed in a workmanlike manner according to standard practices. Any alteration or deviation from above specifications involving extra costs wit become en extra charge over and above ere estimate.An agreements contirsjent upon Anises,accidents,weather or delays beyond our control,Owner to catty fire and extended coverage insurance.Our workers are fully covered byworkers'compensation insurance. interstate Roofing and the materiel supplier have no control over the quality of the product or the length of time the manufacturer claims the product will last.The manufacturer has sole!lability for the product A late change of 15%per mouth ox maximum allowed by law Will be applied to accounts unpaid for over 30 days.We are able to accept Visa.Mastercard and Discover with an additional 1,5%processing fee, • sales Representatfye:Terry Nation Date:0427'_17 • This proposal may be withdrawn by us If not accepted within 30 days.All estimates are subject to review by Interstate Management prior to starting the job. ACCEPTANCE OF ESTIMATE: The above prices,sper3dcattons and conditions are satisfactory end are hereby accepted.You are authorized to do the work as specified.8y signing this contract,I em indicating that t have received the attached documents.end have read and understand them.I also give Interstate permission to use pictures taken or my property in their advertising.You,the buyer,have the legal right to cancel this transaction at any time prior to midnight of the third business day after the di,f i s trans r o• >.a the. 'ched notes of buyers right to cancel for an oxptanaton of your right to cancel. omerSI.nature I J Date Attached Documents ✓ Required Notices for Residential Construction Projects ✓ Defect Notification Requirement ✓ Consumer Protection Nonce ✓ Notice of Right to Cancel ✓ Notice of Procedure ✓ Moisture Intrusion and Water Damage ✓ Information Notice to Owners about Construction Liens / Interstate Rooting Maintenance fnfomtanon ✓ Notice of Right to Lien ✓ Interstate Roofing Disclaimer Nonce ✓ Ventilation Irtformation ✓ Renovate Right ✓ Manufacturers MateriatlExtonded Warranty ✓ Interstate Roofing Workmanship Warranty ✓ Slate&Federal Contract Addendum Va8'mpetdramplumratte E IVluareR.Ewdni OREGON fIr 55485 / WASRINGTON fr: INTERR1077KIC SCOPE OF WORK(Preventative Maintenance&Torchctown Repair) Setup safety per OSiiA stsodards Seal around all pipes,penabtatfona and corners Seal around any visuauy noticed splits Scaling is 3 course method&covered with granules Remove wall metal on drain side of roof up to the bottom of the windows Rework lead collars around 3 drains On drain side of roof approximately 10'x1 t38'install new torch down over the top of existing roof Install now wall metal over the top of With down roof and up to the flashing detail under windows on wall Cleat up and properly dispose of all roofing related debris Assumptions:Electrical must be removed and replaced by others as needed.HVAC curbs and ductwork should be replaced by others as needed.Interstate Roofing is not responsible for evaluation of overflow drainage systems.Overflows should be installed by others. Dust will fail through existing decking.Parking lot will be made available for roof restoration project The Owner realizes that fasteners through the roof deck may be visible from the interior in exposed locations. Interstate assumes that neither lead,nor asbestos containing roofing materials(ACRM)exist;if lead or ACRM are discovered it will be contained and/or abated in accordance with local,state and federal requirements at an additional cosi, GAF Well Roof 25%Warranty Extension on TPI?roof. 20 year extends to 25 years Well Roof Preventative Maintenautca,5400 per visit,for the first 3 visits. Accept[,, ..DecIinet I NOTE(1):All electrical and gas lines,HVAC and ductwork preparation,removal,repair,andlor replace tis .:f included unless stated Damage to the above mentioned is not the responslbllky of Interstate Rooting Inc. NOTE(2):Taper systems are recommended and a quote can be given upon request Even with a taper system,ponding water will still occur. NOTE(3):Seismic upgrades arc not included and It Is the building owner's responsibility to notify us if one is required. WE PROPOSE HEREBY to furnish material and labor—complete in accordance with the above epeeitmtioos forthe contract amount stated above,Was hot Included.Payment to be made es follows:30%due upon acceptance;balance due upon completion.Ifa job has phases;rooting,tiding,windows.gutters,etc. payments will be phased also,Interstates maximum liability under this agreement for any reason shall not exceed the contract amount Interstate Roofing It a certified fin authorized to conduct lead-based paint activities and working with asbestos under certain conditions,however,the above price and scope of work,unless specifically stated above,is based on not encountering lead,asbestos,or any other toxic material In,on or around the jobsile.Usual h materdals ave found.Interstate shall be endued to additional time end compensation based upon the below lime and materiel rates•.Home/Building Owners andlor Owner's Agent are responsible for notifying Interstate Of any asbestos containing,lead containing,or other toxic materials on ale,itis the building owner's andlor owner's agent responsibly to:notify tenant of presence of lead paint,asbestos,and/crony Other toxic containing material,and notify tenants that lead containment work and/orother toxic containing material work may occur while job is being performed,end to provide tenants with the Renovate Right pamphlet The above scope of work and investment are based solely upon a Vora,'observation.During the project other deticlencles may be discovered which require additional work,for example:eidewats and other wells may need to be altered;Chimney sledding may need to he altered,adddenat ve1161ao21 may he needed (both intake and exhaust),but not invited to these items.This work will be billed to the customer at the below time and material rates.'Interstate Roofing is a preteosional roofing contractor,nota designer.The roof is just one factor in the larger balding envelope.As building elements are updated end building occupancy andwor functions change,the importance of all components working together is imperative(i.e.roof,air barriers,exterior cladding,windows,and crawl spaces). Modem construction requires that at facets of the building are evaluated by a building envelope con alta nt or design prokssionat. 'Some additional work may be needed,for example:dry rot,delaminated plywood,fascia boards and rafter tarts,but not limited to these items.This work is baled to the customer at 580,00 per man-hour pies materials,disposal,mobilization and markup.To not slow the progress of the job,this may be done as it occurs;written change orders are not required.The above stated price is based upon one mobilization.Multiple reobnrzetiwrs for such conditions,but not limited to:dry in,separate trades coordination,etc.will be billed on the before mentioned time and material basis.Although interstate end most manufacturers recommend to always remove all layers diming,we recognize that many of ourcustomeo would Oke the option Ma recover.In the case of a recover,It Is not possible to determine if roto present therefore Interstate is not responsible for covering over rot organic growth,or any othersort of microbial growth, This roofing project u designed to protect the topside of the root decking from the elements.Commencement of the roof work inddestes only that the surface of the deck appears satisfactory to attach rooting materials.Interstate Roofing cannot he held responsthle for any pre-existing issues,or issues that may arise during or after the completion of the project that have to do with anything below the topside of the loaf decking,for example:organic growth,mildew,Or any other microbial growth anywhere in the building or attic epecelcavity,ducting,and ducting connections,fans(bath fans,kitchen fans,dryer fans,etc.),firewall venting,insulation, blodhage of or lack of Intake and/or exhaust ventilation,but not limited to these items,are also not the responsaotey of Interstate. His the owner's and/or owner's agent's respansibitity to notify Interstate Rooting if any federal endforstate money is being used to fund this project,as additional work andlor cuts are oftentimes regtii+ead,If this job requires certified payroll or the payment of Davis Bacon wages,itis the owner's responsibility to notify Interstate of the wage prior to bid.Unless specifically stated above,the price and woof work are based on standard interstate wages.Ir not noticed,Interstate cannot be held responsthle for any additional fees/costs. positively connecting ducts to vents andror tens is not included in the scope of work end is not the tesponsiblily of Interstate.This type of work should be completed by a licensed HVAC contractor after the roofing project is completed,Scheduling and budgeting for this process Is the tesponsiblcty of the owner.Interstate strongly suggests a professional HVAC contractor inspect ducting after the roofing project is completed. Owner understands that interstate is completing the above stated work on an apartment.Owner agrees that the building will not undergo a condo conversion.If Owner chooses to convert the(wilding,Owner will defend,indemnify and hold Interstate harmless from damages related to claims by HOA or members.Owner further tarderstenee that Interstate may not have adequate inzurarme for condo related rink,and will:tame insurance that caldera condo related rialm.Further,the HOA is required to accept the terms and conations of this contract,Including put not limped to the Imitation on actions and arbitration provision, Interstate is not responsible(or ore safely of persons on the roof other then Its own employees,regardless of how they access the root.Ovmer and/or Owner's Agent agree to indemnify and hold Interstate harmless,including attorney's fees,from claims for personal injury by persons or entities whom Owner or Owner's Agent have alowed or authorized to be on the roof. OREGON#: 55485 / WASHINGTON I/; INTERRI077I'K Product Data Sheet EverGuard® TPO Title 24* ��� 60 mil Membrane Compliant MI= • Description GAF EverGuard®TPO 60 mil thermoplastic polyolefin single-ply membrane systems have been engineered to provide superior long-term performance and enhanced durability.Strong,flexible EverGuard TPO 60 mil membrane is suitable for use in all types of single-ply systems:Mechanically Attached,Fully Adhered, and Ballast Applied Compared to other heavy-duty single-ply EPDM,PVC and TPO membranes,GAF EverGuard TPO 60 mil roofing membrane provides the benefits of all three materials in a single membrane:low installed cost,heat welded seams,white reflective color,and no liquid plasticizers. Applicable Standards UL approved for use in the construction of Class A,B,or C roofs,FM Approved,ASTM D6878,Dade County Product Approval,ICC-ES Legacy Report MR-6030 tijhx"`.u.k f v-ri gy,.:,u31z<<K't1iL.ter �' �s,r�. $:e,f r' �` ,x � � :1 Ca7i7S erliegLV::5 :aigTeS�t VlellloTl`' r� 57:.%:-(`:-rte, Y 1 1 '''b kg > 3'a'tk,b/00L =nm, ,7 -,LtierGuarra yscal ` ,.,. ''77'.�t �..��,,,5 '�f e.* 7 �l ,27;,,,.l"6-,_, z,,,,,-'e`L .? ,,Tf.rr,;ly l r `a ,. r s t t '7 -S est"rata �. y- ....r'-,.� }a ,�r� t x_.::<..er:i4-J.-4'.:.a<,, .�,�. ' -• ~ r Y;r7 1.Certain data is provided in MD(machine direction)x CMD(cross machine direction)format. 2.Data is based upon typical product performance,and is subject to normal manufacturing tolerance and variance Nominal Thickness ASTM D-751 0.039"(min.) 0.060" Breaking Strength ASTM D-751 Grab Method 220 lbf/in. 320 lbf x 270 lbf Factory Seam Stren: - •STM-D--751 << bf embrane-aii.i Elongation at Break ASTM D-751 15% 28% Heat Aging ASTM D-573 90%Retention of Breaking 100% Strength and Elongation at Break Tear Strength ASTM D-751 8"x 8"Sample 55 lbf 70 lbf x 150 lbf Puncture Resistance FTM 101C Method 2031 Not Established 380 lbs. Cold Brittleness ASTM D-2137 -40 C -40 C Permeance ASTM E-96 Not Established 0.01 Perms Dimensional Change ASTM D-1204 @158 F,6 hrs. +/-1% 0.4% Water Absorption ASTM D-471 @158 F,1 week +/-3.0%(top coating only) 0.7% Hydrostatic Resistance ASTM D-751Method D Not Established 430 psi Ozone Resistance ASTM D-1149 Pass No visible deterioration No visible deterioration @ 7 x magnification @ 7 x magnification Reflectivity ASTM C1549&E408 N/A 0.76 Emissivity ASTM E408 N/A 0.90 Product Data :Roll Size : ..Note:Product sizes,dimensions,and widths are nominal values and are subject to normal manufacturing/packaging tolerance and variation Clolors= ' iII Roll Size :Full Roll'Might rt1f.Roll Size ;Ralf RollWeight. White,Tan,Gray 10'x 100' 322 lbs. 5'x 100' 162 lbs. (1,000 sq.ft.) (500 sq.ft.) Note:Membrane rolls shipped horizontally on pallets. Storage Store rolls on their sides on pallets or shelving in a dry area ,.Safely Warning Membrane rolls are heavy,and are best positioned and installed by at least two people *White Membrane Only Product Data Sheet 2 14 1 Product Comparison SE CUOCK HighPerformance Guide Roof Boards USG has a full range of high-performance roof board products, giving consumers a choice in the roof board industry. SECUROCK Gypsum-Fiber roof board outperforms the competition and is made from 95 percent recycled material.SECUROCK Glass-Mat roof board meets the stringent performance requirements and specifications of competitive glass-mat roof boards while being easier to handle.Plus,both boards come with the customer service,flexibility and responsiveness that only USG • can deliver.All of this adds up to a roof board portfolio that goes above and beyond the competition. SECUROCK Glass-Mat Roof Board Performance 1/4"SECUROCK 1/4"DENSDECK' 1/2"SECUROCK 1/2"DENSDECK' 5/8"SECUROCK 5/8"DENSDECK' Glass-Mat Glass-Mat Glass-Mat Compressive strength,psi 700-1000 900 700-1000 900 700-1000 900 ................................... Flute span 2-5/8" 2-5/8" 5" 5" 8" 8" Bending radius 4' 5' 6' 8' 9' 12' Flexural strength,Method B,parallel, 40 40 80 80 100 100 lbf.min.per ASTM C473 Permeance,perms 18 50 18 35 16 32 Water absorption,%max,per ASTM 10 10 10 10 10 10 C473 Mold resistance per ASTM D3273* 10 N/A3 10 N/A' 10 N/A' ASTM Standard C1177 C1177 C1177 C1177 • C1177 C1177 SEcuaocK Gypsum-Fiber Roof Board Performance 1/4"SECUROCK 1/4"DENSDECK 3/8"SECUROCK 1/2"DENSDECK 1/2"SECUROCK 5/8"DENSDECK 5/8"SECUROCK Gypsum-Fiber Prime' Gypsum-Fiber Prime' Gypsum-Fiber Prime' Gypsum-Fiber Compressive strength,psi 1800 900 1800 900 1800 900 1800 ,Flute span 2-5/8" 2-5/8" 5" 5" 8" 8" 10" Flexural Strength,Method B,parallel, 40 40 70 80 110 100 155 lbf.min.per ASTM C473 Nail pull resistance,min.lbs./ft. 80 402 110 802 120 902 145 Permeance,perms 30 50 26 35 26 32 24 .................... ....... Water absorption,%max,per ASTM 10 10 10 10 10 10 10 C473 Mold resistance per ASTM 03273* 10 N/A' . 10 N/A' 10 N/A' 10 ASTM Standard C1278 01177 C1278 01177 C1278 C1177 C1278 *ASTM D3273 Mold Resistance Testing-In independent lab tests conducted on Securock Gypsum-Fiber roof board and Securock Glass-Mat roof board at the time of manufacture per ASTM D3273 Standard Test Method for Resistance to Growth of Mold on the Surface of Interior Coatings in an Environmental Chamber,both panels scored a 10.The ASTM lab test may not accurately represent the mold performance of building materials in actual use.Given unsuitable project conditions during storage,installation or after completion,any building material can be overwhelmed by mold.To manage the growth of mold,the best and most cost-effective strategy is to protect building products from water exposure during storage and installation and after completion of the building.This can be accomplished by using good design and construction practices. A More Economical Product When compared to DENSDECK products,SECUROCK Gypsum-Fiber roof board has better compressive strength and flute spannability.Testing confirms that you can substitute a 3/8"SECUROCK Gypsum-Fiber panel for other 1/2"products and still achieve superior performance. Compressive psi Strength 0 450 900 1350 1800 3/8"SEaRoco Gypsum-Fiber Roof Board 1800 1/2"DENSDECK Prime' 900 Flute Inches Spanability 1 2 3 4 5 3/8"SECUROCK Gypsum-Fiber Roof Board 5 1/2"DENSDECK Prime' 5