Report
01r 77004/1114"4-721:304/1114"4-721 (.'a At OF TIGisa- , N. _. II C DtVtSv` r;w `�' Imperial MOH020X63-LLA IIBROWN Air Cooled / Hermetic ` 4,nr»w;tr ari-,QFC.r, Imperial Brown(Portland Division)-2271 NE 194th-Portland,OR 97230 CCB#0091759 Phone:(503)665.5539 or 1.800.238.4093-Fax:(503)665.2929 Internet:www.imperial-brown.com Physical Data Refrigerant Compressor ___ Connections Receiver Sound Net Weight Altitude Ambient Model# HP Liquid Suction Capacity(90%) Data (lbs.) (Feet) Temp(°F) R404a CS12K6E 2 3/8" 7/8" 9 73 230 1000 90 Electrical Data Power Supply Compressor MCA MOP Notes Volts Phase Hz RLA LRA Air Def. Elec. Def. Air Def. Elec.Def. MCA=Minimum Circuit Ampacity 208-230 3 60 6.7 51 15 24 15 25 MOP=Maximum Overcurrent Protection Left View Front View 44/18 f 1 . A� 2-9/18 ��"�� EP SUCTION -,\ FLOW = == LIQUID 2 9/$ 17-i/4 �* 2-3/4 IV ad=l. � �==. 11 1=3/4 illt ¢ 1-7/8 III i'."f f ..-- 21-1/8 CL 4-9/18 4-1/16 Capacity(BTUH)©Designated Saturated Suction Temperatures +40°F +35°F +30°F +25°F +20°F +15°F +10°F +5°F +0°F 0 0 18,328 16,766 15,163 13,570 11,967 10,374 8,771 -5°F -10°F -15°F -20°F -25°F -30°F -35°F -40°F 7,440 6,109 5,082 4,045 2,966 0 0 0 Imperial LSC090AEQRC6K-EC BROWNIN Low Profile Imperial Brown(Portland Division)-2271 NE 194th-Portland,OR 97230 CCB#0091759 Phone:(503)665.5539 or 1.800.238.4093-Fax:(503)665.2929 Internet:www.imperial-brown.com Physical and Electrical Data Defrost Air Capacity Net Weight Altitude Type Flow (BTUH) (lbs.) (Feet) Air 1400 8,640 68 1000 Power Supply Fans Heaters Connections Volts Phase Hz Qty Amps Motor Type Amps Watts Inlet Outlet Drain 115 1 60 2 1.8 EC 0 0 1/2" 7/8" 3/4" Top, Front and Right Views . -- — .+5.5c -- -- 6.1"i i-- 5.3.i,5 i r.15 j--- ;_u u 1 73 1 3,44 j nlimmomr n �__t (///1/44,=--t ��� 0 ll,'.��� ��:i,j1 ij AIR hliiiit` ii)Pli !flitaitl* 7i j l 1I) hi -'f— \\��\`` ,,�,,,• \\\��` �!% a ii 11* �i '.-,„..''':- --412_,....51y; o e REFRIGERANT n ELECTRICAL r".""----W--y END " SPECIFICATIONS PARTS SPf > " Indoor cooler +35°f (no floor) (4) ea. Kason #1808 vapor proof LED light fixtureStateX . R - ,, ,3 � ( ) (LED lamp built-in.) } -- ,s . O Vinyl foam NSF gasket (1/16' joint thickness), Cam-loch layout #4 (9) ea. (6" x 1 1/2") x 96" x 16 ga. smooth galvanized (w/ Simpson Titen screws) Combiiation interior cove base/seismic tie-down @ floor level (7) ea. Hold downs HD2 with titen concrete screws }—� r.1 r (2) ea. (3" x 52°) 26 ga. Stucco galvalume Interior seismic tie-down @ ceiling level e ' Con�ete '° °C''a {i,,,, 1 //77��7 `1, SPECIAL INSTRUCTIONS (10) ea. (2" x 2") x 96" x 26 ga. Stucco galvalume exterior ceiling strap LSU l5 M Meets 2009 Federal Energy Independence and Security Act Requirements. (10) ea- Angle screed ORS Installedin Concrete Standard crating 11'1 REFRIGERATION 0 Special MAl LAWN THOw WALL PANELS (1) ea. System #1 - Outdoor R404a split system w/ ORCCONSULTING.LLC Construction: 3 1/2" wood frame urethane 16306 BTU/H @ 9.42F TD with 14.7 hr runtime @ 35°F inside/852F outside room Exterior Finish: Stucco galvalume 90°F @ cond. unit, 1000ft altitude 0 aintorcin" Stce1 8, Prestressing Steel Tendons 10372 SW BONANZA WAY CD Interior Finish: Stucco galvalume (1) Heatcraft air cooled condensing unit #M0H020X63-LLA TIGARD,OREGON 67224 Ceiling connections: Camlock 208-230V/3a/60Hz/2HP Hermetic compressor (� Structural ° 'at F+-' g 503-317-1023 Floor connections: Angle screed MCA=15, MOPD =15 °-"� Ltcstructural@gmaicom 37.75W x 28.25D x 17.25H x 2301bs. CEILING PANELS (1) Climate Control low profile evaporator model #LSC090AEORC6K-EC (master) EJ High-Strengh Bolting Construction: 3 1/2" wood frame urethane w/ (2) EC motors (1.82A) & air defrost Exterior Finish: Metal 115V/1a/60HzC3SMasonry Interior Finish: Stucco galvalume 45.5W x 14.84D x 14.94H x 681bs. ..t- Ceiling Caps: Factory mounted (1) Climate Control low profile evaporator model #LSC090AEORC6K-EC (slave) ,. , • ECEIVED Live Load: 10 psf w/ (2) EC motors (1.82A) & air defrost C3 Reinforced Gypsum Concrete *** 115V/1e/60Hz ® DOORS 45.5W x 14.84D x 14.94H x 681bs. insulating Concrete Fill t;i1 if [A]: 36" x 78" flush model G3 self-closing cooler door *** LEAF WILL NOT BE RAISED UNLESS SPECIFIED OTHERWISE OREGON SEAL Frame: 3 1/2' wood frame urethane, 3-sided ❑ Spray Applied Firo-Resistive Materials w/ Stucco galvalume (ext. & int.) AIN 1 b 2017 Q R ff w/ 24 ga. stainless steel 430 (magnetic) liners _ STANDARD NOTES r� t1T Dri]5ecl PEet•es ane Ca ssonS_ 3 b Leaf: 3 1/2" thick, 3-side lap, standard height - To prevent condensation, a minimum 2" from the walk-in exterior surface is required. High h,migq conditions may require force ventilation in 1'I 1{y O F TIGARD w/ Stucco galvalume (ext. & int.) addition to clearance. ' lT 1 if w/ Magnetic gasket 0 ShOt rete B ILDING DIVISION (3) Kason #1248A spring assisted adjustable hinge Installation site floor must be true and level within 3/16" per 10' or additional costs may oe incurred. 1 DIVISION chi i`f E k i (1) Kason #27C cylinder locking deadbolt handle ® Special Grading,Excavation and Filling $ (1) Kason #27C twist-off knob inside release STANDARD ENGINEERING NOTES I (1) Kason #1094 hydraulic door closer Foundation, special inspection, footings, anchor bolt embedment, edge distances and all rerfobq dalified professional(1) 3-way toggle switch w/ pilot light @ ext. engineer based on concrete strength and specific soil condition at the building site. LJ Dt' }uf ` (1) Analog 2" flush mount dial thermometer (12" capillary) Foundation and freezer pit to be designed for loads designated on plan and/or in engineering calcu ations. (1) Terminal J-box @ interior w/ concealed conduit All foundation dimensions to be field verified. Other ilxspec`ors Z All mechanical unit anchorage and support to be designed by others. _ 11 i 0 3 [B]: 36" x 78" flush model G3 self-closing cooler door All connectors or elements in contact with aluminum to be stainless steel (STL/STL). F. *** LEAF WILL NOT BE RAISED UNLESS SPECIFIED OTHERWISE *** If walk-in ceiling is suspended, existing roof structure to be designed by others for loads induced from new walk-ins where shown on plans and/or in Frame: 3 1/2 wood frame urethane, 3-sided engineering calculations. < s w/ Stucco galvalume (ext. & int.) Walk-in is designed for code applied loads. W sip w/ 24 ga. stainless steel 430 (magnetic) liners Design does not include static pressure review. CD Leaf: 3 1/2" thick, 3-side lap, standard height Components of all doors, windows, and openings to be designed for loads induced by wind, design by others. 2 w/ Stucco galvalume (ext. & int.) All loads are service loads. w111 w/ Magnetic gasket Special Inspection is required per IBC 1704 and 1707 for post installed anchor bolts (for California, follow CBC 1704 and 1707). W -J (3) Kason #1248A spring assisted adjustable hinge (1) Kason #27C cylinder locking deadbolt handle WARNING - ELECTRICAL SEAL Q i g (1) Kason #27C twist-off knob inside release After wiring devices, ALL conduits must be sealed to stop moisture transfer through electrical raceways. U (1) Kason #1094 hydraulic door closer Failure to seal device per NEC codes WILL VOID WARRANTY. W F § (1) 3-way toggle switch w/ pilot light @ ext. W (1) Analog 2" flush mount dial thermometer (12" capillary) li I it g (1) Terminal J-box @ interior w/ concealed conduit p (1) Terminal J-box @ interior w/ concealed conduit 0 0 I iY (1) Kason 1832 non-heated air vent 0 z 0 6 5 CITY OF TIGARD6 I [C]: (2) 23" x 79° CDS FS Legacy Series cooler glass door (black frame) o I- II a w/ lights & (7) rows of 27" deep shelves (black) REVIEWED FOR CODE COMPLIANCE 0 o O(1 g/ - 3 �a �r iI 1I1il [D]: (1) 23" x 79" CDS FS Legacy Series cooler glass door (black frame) Q W w/ lights & (7) rows of 27" deep shelves (black) Approved; OTC: -+oasicca' [XX]: GLASS DOOR PARTS (from quote) O1Ci ��� ¢ ��uvw (2) Standard 0-Tech LED lighting Od'c`'�T gp 9340 (1) Standard 0-Tech LED lighting Permit#: L A _ __ — A 107 Q Q coR1-am " REVISIONS Address: - f4 4 174.1A\Ir -4. �zti�ns'C #1: Change glass doors on wall 1 to be hinged from outside 0 K. 7 7 Suite •• �' W-.5 5i E 1111b- ! al= aNte,ii•-' By: `� , Date: 4 (� .....D.,:„.. . r� °jr,C REV# DATE BY .. R G I N ` 06/12/2017 CLM OFFICE COPY 60339aE 4i C i G() t® , , - DO NOT SCALE THIS DRAWING rte,7 , ',,,,k,` SCALE 3/16"=1'-0" `.,,i 1 DATE DRAWN: 4/12/2017 ® NSF LABEL ,Ni DATEPRINTED: 6/12/2017 N.S.F. LISTED (STD #7) BY: CLM N.S.F. GASKET @ ALL PANEL JOINTS EXPli 'S: 6/30/1 e) CHKD BY: DRW#: 17-IB-98533.01 BOX: 1 OF 1 SHEET: 1 OF 4 0 1 � Cr) Q M P.ALIIMN TROMPS 10372 SW BONANZA WAY _� TIGAR OREGON 97224 503-317-1023 CO Ltcstructural@gmaicom 1 N r19'4'[230] 3 g s 1 ac 1 l ; I - 11'-0 (,Sf] 6-2'[74] , i a. —/ L t. \ \ a'`1< 5r16 e7 era yh�W9 W10 Hp2j i i 74 al CS 1 n?L' ,�, N ) fvf by © I I m Pup/dn =0.75k N O �'° ; d I C6 I <^_. o.col - i ? < I 1 (1)ea.,each way I ',Ix rN 1� >" • IL' a LL `> 3'x52'x26gastr�,wl I I ; <ii- W gJ 3 fit x d'MTHSM @ 2•ok, cd I _ a� 22 7/16 Ce 12 ea.side of panel joint I <-4 J v h x.::. C7 Ivy y � DC SPL SPL SPL SPL h I O a-cr, W4 W5 W6lip 1l2 `i Q. 14 314 47 47 47 typ. — lgi ig HW I- — ---' �o1a I -- ��-� �� ; ^ ; 20 ffi I II I Pup/dn COOLER 4 p d rt i I CP CP CP2515/1 CS �I limey < �� I vv^ =0.75k 0 C 243/4 µ 241/2 ., 243/4I,� o 7o m�" -I LSC090AEQRC6K-EC U Z III 1 II aa a� �I C2 C3 0421 1/16 _m__. v_ 2 x 4 bbcking as shown 1 .�r.',:Q�R.:.:::;:;:::::; e $ a F- v, i/z II II _ 3 Q , Ii I CS II Il,...eII N `r'`�SI Wig Wi6 Wil r W16 L•J gi z owm 243/4 241/2 I. 243/4�I " \ \ \ -`�`` 51 P oi Ft ���� L— — _° _-- --JJ V _ V 0 0 arnw,0., w SPL SPL SPL SPL SPL Pup/dn Pup/dn I]r m m Of 1 =0.75k =0.75k W � 1 �z•0.R- CEILING PANELS WALL PANELS (1= a 0v 17'-3'[207J 23 —4a.°(1.4 44'4 E A. REV# DATE BY 0 !� , 06/12/2017 CLM _ , 4,£ 839P>* DO NOT SCALE THIS DRAWING g C'tF GON SCALE: 3/161=1'-0' �G "*},17., �a� \Zs DATE DRAWN: 4/12/2017 (:.4f -, O DATE PRINTED: 6/12/2017 Z 4f M. 1`' BY: CLM - CHK'D BY: E3{ ; 'S: SOI ' DRW#: 17-IB-98533-01 BOX: 1 OF 1 SHEET: 2 OF 4 0 I t_Fs � CO CO - WNW THOMAS COCQ /LTINC.LLC /CO c. 10372 SW BONANZA WAY —� TIGAR OREGON 97224 5033-317-1023 03 Ltcstructural@gmai.com 1/1.D i fio I k. n I 28 23 Dbl 2x4 glue and nail toll length illI A ( �, � 61/2 6112 � typ.both edges of panel;--- I ihk I LA] = W7 W7 m EVATION \ ��� CSL �� H, ®---' r , 1 z - ;r" 1.. 6 I— . I 1 11rt!— . i® 61/2 61/2� o 7_,\ \ csi'I41 VI I6 e� cN—tiii W N g �� -- M a 6§ II soon a - M U ce F s•I I M it I �� iii gg bp c. ciP2=n °Ili6.-41: [A] [B]- W7 0 z o ce9. il Qg I _J L.— _-__, ,_ —i L_ W19 WIS W17 WIS (BI Full length bottom plate 0 p -Cal 5 •a OF illII il (LEVATION Q COMPONENT LOCATIONS ^^ 67C69N P, o I I @ mom.Wo m 5 zb,il ar Nn°.afL -1r 5 P CtCt it REV# DATE DT C.—y 0`"51 G I N F °�!� 7 06/12/2017 CLM 0. �.— 60839PE C G^N DO NOT SCALE THIS DRAWING p� :"'1' 17., 1 `� SCALE: 3/16•=1.-0" �` �j- A1/ M. '`c`0 DATE DRAWN: 4/12/2017 DATE PRINTED: 6/12/2017 BY: CLM EXPIRES: 613O/ - CHK'D BY: DRW#: 17-IB-98533-01 BOX: 1 OF 1 SHEET: 3 OF 4 • r 0 1 @ top 3/81c10 x 3'od 0 M x.156'thick galv.steel /REF Ceiling panel plate washers,w/3/8.0 Lei L/ CO Cam-locks @ 24'0.C. serrated flange nut 8 double 3/8"0 x 12"nylon bottom nut typ(4)min. At exterior 3/8'id 0 x LAO �� THOM all-Ihr� 3"od 0 x.156"thick /Y� Ceiling panel ,., ,., gals.steel plate washers CONSULTING.uc C///�fJtO %�, �'�'r'�'�'r'r'r'r911.111111111111111- :.II0 10372 SW BONANZA WAY TIGARD.OREGON97224�r�` lll11ll i �� 503-317-1023 m /i, 0 0 0 0 0 0 0 ( 'i,%I = 3 Llcslructural@gmaicom 1 4- IIL 2"x 2"x cont x 26 ga 318'ID serrated Sage J II w/#8 x 1/2'MTHSMS @ 6'o/c at ea leg nuts @ext and int N''''w/(7)#8x1/2'@ splices at ea leg pap6"min) SPLICE DETAIL AIR AIR - Wall panel FLOW = FLOW MI t --H› T Wall pared (H)x 112 lvi Evap Unit 1 i (DCHiE;1.-deinNsiGty TIE-DOWN DETAIL LOW PROFILE EVAP HANGER DETAIL W/OVERSIZED WASHER OTHRU BOLT KIT ZZ ) frame panel, camlock max load 70 lbs per rod 4 max load nibs per rod Thru bolt kits supplied only if included on Imperial-Brown quote (6)3/8'id0x3'od0x.156'thickgalv.steel pWOewashers P (6)3/8.13x 12"nylon al-thread i (12)3/8'0 serrated flange nuts w Si 1 N (6)318"0 nuts LLLU CtU W _ ____ _ _ Wg 6 I —till Og C,° ifh@ Wall panel INT. 10 U o p o 3 EXT. 1i" x 6" x 10" long x Q CCI)" L' illIII III 16 ga galv Angle screed (17) #8 x 1/2" plated / \ yolv2` 6\1 o 11/2'x6'xcont tie-downw/3B'radus Tcx • w/#8x1/2"MTHSMS @6"okinto wal panel > o 0 0 0 0 0 0 o MTHSMS staggered p11'��rnui wl 318"x 3'Titen HD @ 36'o/c into floor. Q Q fA'c0 m 13 ° (Min.embed..21/7) N PL 1/4" x 1 1/2" 0 7--► > 0 0 0 0 0 0 o x 10" long plate / li 3/4 WI IA 11/2typ washer steel V ` abvr' � ' Concrete floor(NIC) , a A•sem.c k•• Finish ;�r+L'_'_ ------i-------i------ (2) ea. 3/8" x 3" Titen HD \ ��' �o�ry Floor a�. typ. @ 2 (2 1/2' emb) ; I NWo,fa /MIF ' • "..'n •A• .,•. 3 ii !I 3ii it 's. -----,-,....k r. it EV# DATE BY ` 11/2 y 7 r9 fir— 1 os/12/2017 CLM '' 1 6 8 SPE 4T ANGLE SCREED DETAIL O HOLD DOWN HD2 DETAIL 4 4 4 o.75kN <\ ,e CO - -y' 'y. �,* 3- , DO NOT SCALE THIS DRAWING • ht� F `.�`�d� SCALE: 3/16"=1,-0" �-` DATE DRAWN: 4/12/2017 DATE PRINTED: 6/12/2017 EXPIRES:V 6130/ BY: CLM CHK'D BY: DRW#: 17-IB-98533-01 BOX: 1 OF 1 SHEET: 4 OF 4