Loading...
Specifications 4.4,5p-&/7 -Yiri 1 OFFICE COPY I JUN UN4 A4syO R TI.4 DAiv �iLP � J /) H —! iJ - 0 — `. \ 7irnt = .. NEE Structural Calculations Helical Pier Foundation Repair 15385 SW 79th Ave, Portland, OR 97224 Prepared For:Terra Firma Foundation Systems Work Order: 21165 Date: 7 June 2017 X .RQPN 6/8/17 40 royal@mortiereng.com LiJ .� ;Ia E Royal Mortier, PE 2017.06.08 '' 17:48:23-07'00' SDIGITAL SIGNATURE FOR VERIFICATION OF ELECTRONICALLY b/' 'I. >' ;` TRANSIMITTED DOCUMENTS ONLY. SIGNATURE WILL AUTOMATICALLY «) ( M( `. VOID IF DOCUMENT IS MANIPULATED ELECTRONICALLY. EXPIRE ' 711 _ . N Royal Mortier,P.E. 144 EAST 14TH AVE – EUGENE,OREGON 97401 P: (541)484-9080 – F: (541)684-3597 i Table of Contents Structural Calculations Helical Pier Foundation Repair 15385 SW 79th Ave, Portland, OR 97224 Prepared For:Terra Firma Foundation Systems Work Order: 21165 Date: 7 June 2017 Subject Page Helical Pier Vertical Design 1 Overview 2 Loading 3 Shaft Capacity 4 Helix Capacity 5 Existing Footing Capacity 6 Plans 7 S1—Foundation Plan 8 S2—Helical Pier Details 9 S3—Helical Pier Details 10 144 EAST 14TH AVE — EUGENE, OREGON 97401 P: (541)484-9080 — F: (541)684-3597 Helical Pier Design 15385 SW 79th Ave, Portland, OR 97224 Page 1 . , 1 1Z T/ WORK ORDER# PAGE# �:.• -f f CALCULATIONS 21165 2 STRUCTURAL ,:` j1 BUILDING DESIGN • FIRE PROTECTION PROJECT NAME BY/CHECKED #_ CODE CONSULTANT • PLAN CHECKING 15385 SW 79th Ave.,Portland,OR / • "fj CONSTRUCTION INSPECTION REF DATE FS HP288 Helical Repair for SFD 6/7/2017 'Structural Design Narrative The structural calculations enclosed are in reference to the design of remedial foundation supports for the residence referenced on the cover page.The helical pile system and brackets are designed as foundational supports for the residence to resist loading from the roof,floor,wall,concrete foundation,and concrete slab loading. Helical piles are continuously hydraulically torqued until a load bearing stratum is encountered. It is recommended that the piles be installed at a rate equal to the pitch of the helix plate with no more than 25 revolutions per minute. Confinement of the pile is provided by lateral earth pressures,and an additional external sleeve is used to resist possible eccentric loading. Once all piles are placed to minimum installation torque,they are loaded simultaneously to provide stabilization and/or lifting of the structure,pier caps are then used to lock brackets in place. FSI under-footing brackets do not require mechanical anchorage to the concrete foundation. The vertical and horizontal surfaces of the footing and foundation wall must be smooth and clean to allow full contact with the vertical and horizontal bearing plates of the under-footing bracket. Bracket fabrication welding conforms to AWS D1.1 and has been performed by CWB qualified welders certified to CSA Standard W47.1 in Division 2. Fabrication is performed by Behlen Manufacturing Company. Behlen Mfg Co.is an ISO 9001 certified company. Installation and design shall adhere to the requirements and regulations set forth in ICC-ES AC358 as well as ICC-ESR 3074. Periodic special inspection will be performed and a verification letter of installation depth and pressure will be provided upon job completion. ICC-ESR 3074 currently does not address use of this system within seismic design category D or higher. The entire underpinning system has been reviewed and analyzed and is therefore a fully engineered system complying with all current codes and stamped by a professional engineer. Soil conditions as noted in section 5.5 of ICC-ESR 3074 were not noted in the area. Design reductions,corrosion considerations,and axial and bending capacities of the external sleeve have been incorporated. Concrete foundation span capacities have been analyzed assuming lack of rebar and per ACI 318-11. 'Design Summary-Controlling Parameters Maximum Vertical Load to Pier- 5.754 Ups Pier Type Designation- HP288 Controlling Soil Condition- COHESIVE Maximum Spacing- 6 feet Soil Capacity- 13.40 Ups Installation Torque- 2100 lb-ft Torque Correlation Capacity- 18.90 Ups Pengo RS-7 Diff.Pressure 700 psi Shaft Capacity- 60.37 Ups Installation Depth- 9.00 feet Helix Capacity- 110.00 kips Depth of Helix 1- 8.5 feet Concrete Footing- OK Depth of Helix 2- 5.5 feet Bracket Capacity- 25.3 Ups Depth of Helix 3- N/A feet Page 2 I ',L ' Il�, CALCULATIONS WORK ORDER# PAGE# w�'. - STRUCTURAL 21165 3 11: ' BUILDING DESIGN • FIRE PROTECTION PROJECT NAME BY/CHECKED �, i • CODE CONSULTANT • PLAN CHECKING 15385 SW 79 th Ave.,Portland,OR / �, f.� l .i�..�. CONSTRUCTION INSPECTION G I,' lir REF DATE FS HP288 Helical Repair for SFD 6/7/2017 'Jurisdiction and Codes Jurisdiction/Building Department: City of Tigard Referenced Building Codes: 2012 International Building Code(IBC) 2012 International Residential Code(IRC) 2012 International Existing Building Code(IEBC) 2014 Oregon Structural Specialty Code(OSSC) 2014 Oregon Residential Specialty Code(ORSC) 'Estimated Loading Dead Load: Roof 15 psf Wall 10 psf Floor 12 psf Concrete 150 psf Live Load: Snow/Roof 25 psf Floor(Res) 40 psf 'Vertical Design Loads(Worst Case) Tributary Width/Anchor Spacing= 6 ft Trib Length RoofDL 14 ft = 210 plf Dead Load,D= 2.919 kips RoofSL 14 ft = 350 plf Floor Live Load,L= 1.680 kips #of Floors 1 count = 1 count Roof Snow/Live Load,S= 2.100 kips FloorDL 7 ft = 84 plf Wind Load,+= kips FloorLL 7 ft = 280 plf Wind Load,-= kips Slab? N(Y/N) N (Y/N) Seismic Load,+= kips ConcDL 0 in(thickness) = 0 plf Seismic Load,-= kips ConcLL 0 ft = 0 plf WallDL 8 ft = 80 plf FoundationDL 6 in(width) = 112.5 plf 18 in(heigth) Controlling Load Combination(ASD): D+0.75L+0.75S Maximum Vertical Load(Worst Case)= 5.754 kips Page 3 I lZ T j WORK ORDER# PAGE# ,,, -f.i,, CALCULATIONS 3z . STRUCTURAL 21165 4 BUILDING DESIGN • FIRE PROTECTION PROJECTNAME BY/CHECKED 41 I=a CODE CONSULTANT . PLAN CHECKING 15385 SW 79 th Ave.,Portland,OR / `-j ., �; ` CONSTRUCTION INSPECTION REF DATE FS HP288 Helical Repair for SFD 6/7/2017 'Design Input Pier System Designation= HP288 Vertical Load to Pier,PTL= 5.754 kips Minimum Installation Depth,L= 9.00 ft Unbraced Length,l= 1.000 ft Eccentricity,e= 6.000 in Concrete to Steel Coefficient of Friction,µ= 0.45 Friction Factor of Safety,FS= 2.00 Normal Surface Force,Fn= 2.877 kips Vertical Component of Tieback,PTB= 0.000 kips Design Load(Vertical+Tieback),PDL= 5.754 kips MomentE«ennieity= 34.524 kip-in Momentneback= 0.000 kip-in Momentp,, ion= 0.000 kip-in Design Moment,Momentpie,DL= 34.524 kip-in Sleeve Property Input Sleeve Length= 30 in Sleeve OD= 3.500 in Design Wall Thickness= 0.201 in Sleeve Design ID 3.098 A= 2.082 in` I= 2.843 hi' S= 1.625 in' Z= 2.189 in' r= 1.169 in E= 29000 ksi Fy= 60 ksi 'Pier Property Input Plain Pier OD= 2.839 in *Pier properties based on 50 year corrosion loss in Design Wall Thickness= 0.221 in thickness per ICC-ES AC358. Plain Pier Design ID= 2.397 in A= 1.818 in` I= 1.568 in' S= 1.105 in' Z= 1.518 in' r= 0.929 in c= 1.420 in k= 2.100 E= 29000 ksi Fy= 60 ksi 'Pier Output(AISC 325-11) kl/r= 27.13 <200-OK Fe= 319.70 ksi 4.71*(E/Fy)o'= 103.55 Fr= 55.47 ksi Pn= 100.82 kips Safety Factor for Compression,Ste= 1.67(ASD) Allowable Axial Compressive Strength,P„/52e= 60.37 kips Actual Axial Compressive Demand,Pr= 5.754 kips D/tp1e,= 12.85 <.45E/Fy-OK Mp= 222.45 kip-in Safety Factor for Flexure,S2b= 1.67(ASD) Allowable Flexural Strength,M„/521,= 133.20 kip-in Actual Flexural Demand,Mr.= 34.52 kip-in Combined Axial&Flexural Check= 0.31 OK Page 4 7,..--!--.0, R F/l-, W21°16111(5 ORK ORDER# PAGE# ,•• - r) CALCULATIONS 21165 5 s' STRUCTURAL PROJECT NAME BY/CHECKED (� fli' I a BUILDING DESIGN • FIRE PROTECTION 15385 SW 79 th Ave.,Portland,OR / { ,, CODE CONSULTANT • PLAN CHECKING REF DATE- ..fix CONSTRUCTION INSPECTION 1(�J� \-- FS HP288 Helical Repair for SFD 6/7/2017 'Helix Properties and Capacity Dl= 8.00 in Qi= 55 kips Al=p*D12/4= 50.27 in` HP288(Per ICC-ESR-3074) D2= 10.00 in Capacity Q2= 55 kips Helix dia.(in) (kips) A2=p*D22/4-p*(Tube OD)2/4= 72.21 in` 8 55.000 D2= in 10 55.000 Q3= 0 kips 12 55.000 A3=p*D32/4-p*(Tube OD)2/4= 0.00 14 55.000 EQ= 110.00 Ups ISoil-Individual Bearing Method-Cohesive or Non-Cohesive Cohesive Non-Cohesive Factor of Safety= 2 Factor of Safety,FS= 2 Blow Count,N= 12 Y= 120 pcf EAh=A,+A2+A3= 0.85 ft2 cp= 32 deg Cohesion,c= 1.750 ksf Depth of Helix,D,= 8.5 ft Ne= 9 Depth of Helix,D2= 5.5 ft n Qt,=Eah(cNC)= 13.396 kips Depth of Helix,D3= 0 ft Qa,compression/tension=Qu/FS= 6.698 kips q'1=Y*Dl= 1020 psf q'2=Y*D2= 660 psf q'3=Y*D3= 0 psf Ng=1+0.56(12*cp)`P/54= 20.04 Q1u=A1(q',Nq)= 7.135 Ups Q2„=A2(q'2Nq)= 6.632 Ups Qin=A3(q'3Nq)= 0.000 Ups Qa,compression/tension=EQ„/FS= 6.883 Ups CONTROLS: COHESIVE ALLOWABLE: 6.698 KIPS OK (Soil-Torque Correlation Factory of Safety,FS= 2 Design Work Load,DL= 5.754 kips Emperical Torque Correlation Factor,K,= 9 ffi Final Installation Torque,T=Q1//Kt= 2100 lb-ft Ultimate Pile Capacity,Q„= 18.90 kips Allowable Pile Capacity,Qa= 9.45 kips OK Page 5 J WORK ORDER# :AGE# (<1,k..1. ..•�-1 � CALCULATIONS .` STRUCTURAL 21165 `� G' I BUILDING DESIGN • FIRE PROTECTION PROJECT NAME BY/CHECKED CODE CONSULTANT • PLAN CHECKING 15385 SW 79 th Ave.,Portland,OR / �� ��,� CONSTRUCTION INSPECTION REF DATE JA�'I"� FS HP288 Helical Repair for SFD 6/7/2017 'Estimated Footing/Foundation Wall Properties Foundation Width,b= 6 in Foundation Depth,d= 18 in Cross Sectional Area,A= 108 in` Section Modulus,S,,= 324 in' Moment of Inertia,M„ 2916 in4 Assumed Conc,fc= 2000 psi 'Footing/Foundation Wall Loading Dead Load,DL= 2.919 kips Factored Dead Load,DL= 3.503 kips Floor Live Load,LL= 1.680 laps LRFD Load Factors: Factored Floor Live Load,LL= 1.680 kips 1.2DL+I.OLL+1.6SLr Snow/Live Roof Load,SL,= 2.100 kips Factored Snow/Live Roof Load,SL,= 3.360 kips Factored Total Load,W = 8.543 kips Pier Spacing,S= 6.0 ft Ultimate Shear(W/2),V„= 4.27 kips Ultimate Moment(wS2/8),M„= 6.41 k-ft 'Estimated Footing/Foundation Wall Capacity(ACI 318-11) Conc.Modulus of Rupture,ft= 335 psi Shear Strength,Vc= 9.66 kips Shear Redution Factor,cp= 0.75 Design Shear,cpVu= 7.24 kips OK Cracking Moment,MR= 9.06 k-ft Flexure Reduction Factor,cp= 0.9 Design Moment,cpMR= 8.15 k-ft OK Page 6