Loading...
Report (45) /ufCX e?—C 25 4 GAS FURNACES M L193 D F trwwnr') MERIT® SERIES ® Downflow PRODUCT SPECIFICATIONS Bulletin No.210589 March 2014 Supersedes December 2013 ' � LENNO� ( 1E1a s, , '' JUN g 2.°17 [$ g/ kit 1) i -. IuDic . a l 4\ .1-,„:4'� r .l - AFUE - 93% Input - 44,000 to 110,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons MODEL NUMBER IDENTIFICATION M L193 DF 070 X P 36 B Unit Type 'Cabinet Width ML=Merit®Series o =17-1/2 in. C=21 in. Stages 1=One-Stage Nominal Add-On Cooling Capacity AFUE '36=3 tons 93=93% 48=4 tons 60=5 tons Configuration DF=Downflow Blower Nominal Gas Heat Input P=PSC Multi Speed Blower Motor ' 045=44,000 Btuh 070=66,000 Btuh 090=88,000 Btuh Low NOx=Units meet California 110=110,000 Btuh Nitrogen Oxides standards 'Indoor coils with the same letter designation will physically match the furnace, \riSPECIFICATIONS Gas Model No. ML193DF045XP36B ML193DF070XP36B ML193DF090XP48C ML193DF110XP60C Heating Performance 'AFUE 93% 93% 93% 93% Input-Btuh 44,000 66,000 88,000 110,000 Output-Btuh 41,000 61,000 82,000 102,000 Temperature rise range-°F 25-55 40-70 40-70 40-70 • Gas Manifold Pressure(in.w.g.) 3.5/10.0 3.5/10.0 3.5/10.0 3.5/10.0 Nat.Gas/LPG/Propane High static-in.w.g. 0.50 0.50 0.50 0.50 Connections Intake/Exhaust Pipe(PVC) 2 12 2/2 2/2 2/2 in. Gas pipe size IPS 1/2 1/2 1/2 1/2 Condensate Drain Trap(PVC pipe)-i.d. 3/4 3/4 3/4 3/4 with furnished 90°street elbow 3/4 slip x 3/4 Mipt 3/4 slip x 3/4 Mipt 3/4 slip x 3/4 Mipt 3/4 slip x 3/4 Mipt with field supplied (PVC coupling)-o.d. 3/4 slip x 3/4 MPT 3/4 slip x 3/4 MPT 3/4 slip x 3/4 MPT 3/4 slip x 3/4 MPT Indoor Wheel nom.dia. x width-in. 10 x 8 10 x 8 10 x 10 11-1/2 x 10 Blower Motor output-hp 1/3 1/3 1/2 1 Tons of add-on cooling 2.5-3 2.5-3 3-4 4-5 Air Volume Range-cfm 605-1615 560-1550 920-2145 1210-2410 • Electrical Voltage 120 volts-60 hertz-1 phase Data Blower motor full load amps 6.1 6.1 8.2 11.5 Maximum overcurrent protection 15 15 15 15 Shipping Data lbs.-1 package 124 129 147 162 NOTE-Filters and provisions for mounting are not furnished and must be field provided. 'Annual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations.Isolated combustion system rating for non-weatherized furnaces. INSTALLATION CLEARANCES Sides 1 0 inches(0 mm) Rear 0 inches(0 mm) Top/Plenum 1 inch(25 mm) Front 0 inches(0 mm) Front(service/alcove) 24 inches(610 mm) Floor 2 Combustible I NOTE-Air for combustion must conform to the methods outlined in the National Fuel Gas Code(NFPA 54/ ANSI-Z223.1)or the National Standard of Canada CAN/CSA-B149.1"Natural Gas and Propane Installation Code". NOTE-In the U.S.flue sizing must conform to the methods outlined in the current National Fuel Gas Code(NFPA 54/ANSI-Z223.1) or applicable provisions of local building codes.In Canada flue sizing must conform to the methods outlined in National Standard of Canada CAN/CSA-B149.1. 'Allow proper clearances to accommodate condensate trap and vent pipe installation. 2 Clearance for installation on combustible floor if Optional Downflow Combustible Flooring Base is installed between furnace and combustible floor.Not required in add-on cooling applications if installed in accordance with local codes or National Fuel Gas Code ANSI-Z223.1 or CAN/CGA-149.1,.2.Do not install the furnace directly on carpeting,tile,or other combustible materials other than wood flooring. ML193DF I Page 6 DIMENSIONS - INCHES (MM) 9/16 Ti-(14) - Flue Condensate Trap Assembly COMBUSTION Furnished for external 7 AIR INTAKE field installation r� (178) I RETURN AIR • on either side of unit. ( ) EXHAUST AIR 1 OPENING (See installation instructions 'am OUTLETfor additional 1� \information.) '�-•+�' r : + �'� 2-1/16(52) . 111 �� , 2-1/4 +9/16 )/ (57) (14) --1.---1.- 5(127) TOP VIEW Front Panel (705) B 0 f 9/16 • 19-7/16 9/16 (14) (494) (14) . AIR.j FLOW 1 v ,, rT1 A O ELECTRICAL INLET 7 (Either Side) - OO . . 2(51) . . 33 Either Side (838) GAS PIPING INLET CONDENSATE Side) ----, (Either Side) 'TRAP CONNECTION (Either � + Ilk t 9-1/8(232)Right 9(229) O 6-9/16(167)Left 6-7/16(163) Either Side .Either Side Supply 3/4 x_19-114 Supply 3/4 (19) ► • C Air3/4 I. a—(19) (489) Air (19) FRONT VIEW SIDE VIEW Model No. A B C 1 in. mm in. mm in. mm ML193DF045XP36B 17-1/2 446 16-3/8 416 16 406 ML193DF070XP36B - ML193DF090XP48C 21 533 19-7/8 505 19-1/2 495 ML193DF110XP60C ML193DF/Page 10 ADITIO IR CONDITIONERS 13ACX (7/1 FAIN I MERIT® Series R-410A PRODUCT SPECIFICATIONS Bulletin No.210563 April 014 Supersedes December 2013 4.11'4,7 P-..,(7.:::::.^.... '• � .. 4§, ' ��. � 0 -N-:.'. 44= - Rupto00 1.5 to5Tons Cooling Capacity - 18,000 to 59,000 Btuh MODEL NUMBER IDENTIFICATION 13 ACX - 024 - 230 - 17 Nominal SEER Minor Revision Number Unit Type Voltage AC=Air Conditioner 230=208/230V-1 phase-60hz • Refrigerant Nominal Cooling Capacity X=R-410A 018=1.5tons 024=2 tons ` 030=2.5 tons 036=3 tons 042=3.5 tons 048=4tons 060=5 tons % SPECIFICATIONS General Model No. 13ACX-018 13ACX-024 13ACX-030 13ACX-036 13ACX-042 13ACX-048 13ACX-060 Data Nominal Tonnage 1.5 2 2.5 3 3.5 4 5 Connections Liquid line o.d.-in. 3/8 3/8 3/8 3/8 3/8 3/8 3/8 (sweat) Suction line o.d.-in. 5/8 5/8 3/4 3/4 3/4 7/8 7/8 Refrigerant(R-410A)furnished 3 lbs. 15 oz.3 lbs. 15 oz. 5 lbs.2 oz. 5 lbs.4 oz. 6 lbs. 8 oz. 7 lbs. 12 oz. 9 lbs.0 oz. - RFCIV Metering Orifice Size 0.051 0.057 0.065 0.072 0.076 0.082 0.090 Outdoor Net face area Outer coil 11.33 11.33 13.22 13.22 16.33 18.67 16.33 Coil sq.ft. Inner coil --- --- --- --- --- --- 15.71 Tube diameter-in. 5/16 5/16 5/16 5/16 5/16 5/16 5/16 Number of rows 1 1 1 1 1 1 2 Fins per inch 26 26 26 26 26 26 22 Outdoor Diameter-in. 18 18 18 18 22 22 22 Fan Number of blades 3 3 4 4 4 4 4 Motor hp 1/10 1/10 1/5 1/5 1/4 1/4 1/4 Cfm 2350 2350 2400 2400 3500 3670 3600 Rpm 1010 1010 1090 1090 825 835 830 Watts 165 165 185 185 300 295 285 Shipping Data-lbs. 1 package 138 138 144 151 188 195 218 ELECTRICAL DATA Line voltage data-60 hz-1 ph 208/230V 208/230V 208/230V 208/230V 208/230V 208/230V 208/230V 2 Maximum overcurrent protection (amps) 20 30 30 35 45 50 60 3Minimum circuit ampacity 12.0 17.6 18.7 22.0 28.1 31.9 34.6 Compressor Rated load amps 9.0 13.5 14.1 16.7 21.2 24.2 26.3 Locked rotor amps 48 58.3 73 70 90 100 125 Power factor 0.98 0.98 0.98 0.99 0.99 0.99 0.99 - Condenser Full load amps 0.7 0.7 1.1 1.1 1.7 1.7 1.7 Fan Motor Locked rotor amps 1.3 1.3 2.0 2.0 3.2 3.2 3.2 OPTIONAL ACCESSORIES - ORDER SEPARATELY Compressor Crankcase Heater 93M04 • 93M05 • • • Compressor Hard Start Kit 10J42 • 88M91 • • Compressor Low Ambient Cut-Off 45F08 ' Compressor Sound Cover 69J03 • Compressor Time-Off Control 47J27 • Freezestat 3/8 in.tubing 93G35 • • • 5/8 in.tubing 50A93 • • • Indoor Blower Off Delay Relay 58M81 ' • Loss of Charge Switch Kit 84M23 ' • °Low Ambient Kit 34M72 • • • • • • • Mounting Base 69J06 • • 69J07 • Refrigerant L15-26-20, LI5-26-25, • • Line Sets L15-26-35, L15-26-50 L15-41-20, L15-41-30, • L15-41-40, L15-41-50 • L15-65-30, L15-65-40, • • L15-65-50 Unit Stand-Off Kit 94J45 • • • • NOTE-Extremes of operating range are plus 10%and minus 5%of line voltage. 'Refrigerant charge sufficient for 15 ft.length of refrigerant lines.For longer line set requirements see the Installation Instructions for information about line set length and additional refrigerant charge required. 2 HACR type circuit breaker or fuse. 1 Refer to National or Canadian Electrical Code manual to determine wire,fuse and disconnect size requirements. 4 Crankcase Heater and Freezestat are recommended with Low Ambient Kit. 13ACX-1.5 to 5 Ton Air Conditioner /Page 6 1 . t DIMENSIONS - INCHES (MM) i 4-3/8 f —4-3/8..,1__ INLET,a AIR (111) (111) 4-318 4-318 (111) /� /� 1\ (111) • OPTIONAL UNIT// 'N t INLET j INLET STAND-OFF KIT(4) / `� ` (Field Installed) L CpMPRESSpR AIR ` AIR COIL DRAIN OUTLETS// (Around perimeter of base) AI\ N, 6-3/8 ° J CONNECTION LINE (162) \ 4-318 /... CONNECTION i , I (111) INLET 4 AIR \LIQUID LINE f CONNECTION 6-3/8 4-3/8 (162) (111) TOP VIEW TOP VIEW BASE SECTION r."11 A . A I.OUTDOOR T DISCHARGE AIR COIL FAN � J I / • ............ ..ITEll 1-H'.—. • COMPRESSOR -- - C B I a MOM a MIS MIMI IMM MI i SUCTION AND LIQUID LINE i I awn=!UM CONNECTION\ Nimons MOM AMOK MOM ELECTRICAL i MM i --INLETS §-pot • 2-3/4(70) • i. ■ ■I 2(51)NM= =NM IA tics -/ u T SIDE VIEW 3/4(19) f OPTIONAL STANDOFF KIT(4) SIDE VIEW (FIELD INSTALLED) A B C Model No. inches mm inches mm inches mm 13ACX-018 24-1/4 616 25-1/4 641 24-1/4 616 13ACX-024 24-1/4 616 25-1/4 641 24-1/4 616 _----" 13ACX-030 24-1/4 616 29-1/4 743 28-1/2 724 • 13ACX-036 24-1/4 616 29-1/4 743 28-1/2 724 13ACX-042 28-1/4 718 29-1/4 743 28-1/2 724 13ACX-048 28-1/4 718 33-1/4 845 32-1/2 826 13ACX-060 28-1/4 718 29-1/4 743 28-1/2 724 13ACX-1.5 to 5 Ton Air Conditioner /Page 7