Loading...
Report (21) Ste/ 7-_600 ?/ tit ,(41,014 kJ,/ 115-575- Sr fsq leo JON 9 - fug FIRE PROTECTION, INC. 9095 S.W. Burnham Tigard, OR 97223 PCC 226-100 COMMON AREAS 15575 SW SEQUOIA PKWY #100 PORTLAND, OR 97224 FIRE PROTECTION EQUIPMENT SUBMITTAL 1zcciWorldwide Fire Protection Contacts www.tyco-fire.com Products Series TY-B, 5.6 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General NOTICE The Series TY-B Sprinklers described , ii,Description herein must be installed and maintained in compliance with this document, as The TYCO Series TY-B, 5.6 K-factor, well as with the applicable standards -'v Upright(TY315)and Pendent(TY325) of the National Fire Protection Associa- • ' Sprinklers described in this data sheet tion,in addition to the standards of any *' ;` are standard response,standard cover- other authorities having jurisdiction. age, decorative 5 mm glass bulb type Failure to do so may impair the perfor- spray sprinklers designed for use in mance of these devices. ' light, ordinary, or extra hazard, com- mercial occupancies such as banks, The owner is responsible for maintain- - 4 hotels, shopping malls, factories, T. their fire protection system and refineries,and chemical plants. devices in proper operating condition. The installing contractor or sprinkler The recessed version of the Series manufacturer should be contacted with TY-B Pendent Sprinkler, where appli- any questions. ' cable,is intended for use in areas with a finished ceiling.This recessed pendent sprinkler uses one of the following: Sprinkler • A two-piece Style 15 Recessed Identification v ri 1,——;" * s'A: :::' Escutcheon with recessed adjust- , " ment up to 5/8 inch (15,9 mm)from Numbers (SINS) the flush pendent position. • A two-piece Style 20 Recessed TY315 Upright 5.6K, 1/2"NPT Escutcheon with recessed adjust- TY325 Pendent 5.6K, 1/2"NPT ment up to 1/2 inch (12,7 mm)from the flush pendent position. Technical The adjustment provided by the Temperature Ratings Recessed Escutcheon reduces the Data 135°F(57°C) accuracy to which the fixed pipe drops 155°F(68°C) to the sprinklers must be cut. Approvals 175°F(79°C) UL and C-UL Listed pp 200°F(93°C) Intermediate level versions of Series FM, LPCB,and VdS Approved 286°F(141°C) TY-B Sprinklers are described in CE Certified 360°F(182°C)t Technical Data Sheet TFP352.Sprinkler guards and shields are described in Sprinklers with Polyester Finish are t UL,C-UL,and VdS Approved only Technical Data Sheet TFP780. UL and C-UL Listed as Corrosion- Resistant Sprinklers. Finishes Sprinkler:Refer to Table A Maximum Working Pressure Recessed Escutcheon:White Coated, 175 psi(12.1 bar) Chrome Plated,or Brass Plated 250 psi(17.2 bar)* *The maximum working pressure of 250 psi Physical Characteristics (17.2 bar)only applies to the listing by Un- Frame Bronze IMPORTANT derwriters Laboratories,Inc.(UL). Button Brass/Copper Always refer to Technical Data Sealing Assembly Stainless Sheet TFP700 for the `INSTALLER Discharge Coefficient Steel w/TEFLON WARNING" that provides cau- K=5.6 GPM/psi1�2(80,6 LPM/bar��2) Bulb Glass tions with respect to handling and Compression Screw Bronze installation of sprinkler systems and Deflector Bronze components.Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 FEBRUARY 2014 TFP152 TFP152 Page 2 of 4 Components: *Temperature rating is ** Pipe thread connections per ISO 7-1 1 - Frame 4 - Bulb indicated on Deflector. can be provided on special request. 2 - Button 5 - Compression STYLE 15 or 20 3 - Sealing Screw ESCUTCHEON PLATE 1/2" 7/16"(11,1 mm) RECESSED Assembly 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON 6* \ ____—.. / 5 �I 7/16" 11MR! _ (11,1 mm) 1■Fc 4 NOMINAL pi 2" �� MAKE-IN (50,8 mm) 1t::— \ �- 2 D l 2" I 1-3/8" I — 3 `� / (50,8 mm) + (34,9 mm) / I VIP 1 11 WRENCH / ' _ FLATS l 1/2"NPT** DEFLECTOR* F 2-7/8"(73,0 mm)DIA. - CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-B UPRIGHT(TY315)AND PENDENT(TY325)SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT,STANDARD RESPONSE L. Operation Installation The glass bulb contains a fluid which The TYCO Series TY-B, 5.6 K-factor, ....17° WRENCH RECESS expands when exposed to heat.When Upright(TY315)and Pendent(TY325) (USE ONLY the rated temperature is reached, the Sprinklers must be installed in accor- END"A") fluid expands sufficiently to shatter the dance with this section. glass bulb, allowing the sprinkler to activate and water to flow. General Instructions FIGURE 2 Do not install any bulb type sprinkler if W-TYPE 6 the bulb is cracked or there is a loss of SPRINKLER WRENCH Design liquid from the bulb.With the sprinkler held horizontally, a small air bubble WRENCH Criteria should be present.The diameter of the RECESS The TYCO Series TY-B, 5.6 K-factor, air bubble is approximately 1/16 inch Upright(TY315)and Pendent(TY325) (1,6 mm) for the 135 F (57 C) to 3/32 Sprinklers are intended for fire rotes- nch temperature2,4 mm) forgthe 360 F (182 C) S1,1-"- ) tion systems designed in accordance obtratings. with the standard installation rules A leak-tight 1/2 inch NPT sprinkler recognized by the applicable Listing joint should be obtained by applying a or Approval agency (e.g., UL Listing minimum-to-maximum torque of 7 to 14 2,•H is based on the requirements of NFPA ft.-lbs. (9,5 to 19,0 Nm). Higher levels firill It 13, and FM Approval is based on the of torque may distort the sprinkler inlet PUSH WRENCH requirements of the FM Loss Preven- and cause leakage or impairment of the INTO ENSURE tion Data Sheets). Only the Style 15 sprinkler. ENGAGEMENT or Style 20 Recessed Escutcheon, as Do not attempt to compensate for WITH SPRINKLER applicable, is to be used for recessed insufficient adjustment in the escutch- WRENCHING AREA pendent installations. eon plate by under-or over-tightening FIGURE 3 the sprinkler. Readjust the position of W-TYPE 7 RECESSED the sprinkler fitting to suit. SPRINKLER WRENCH Upright and Pendent Sprinklers The Series TY-B Upright and Pendent Sprinklers must be installed in accor- dance with the following instructions. Step 1. Install pendent sprinklers in the pendent position; install upright sprinklers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. TFP752 Page 3 of 4 Step 3. Tighten the sprinkler into the 2-7/g° DIA. sprinkler fitting using only the W-Type (73,0 mm) - 6 Sprinkler Wrench (Figure 2). With reference to Figure 1,apply the W-Type 2-1/4" DIA. 6 Sprinkler Wrench to the wrench flats. FACE OF — (57,2 mm) — Torque sprinklers 7 to 14 ft.-lbs.(9,5 to SPRINKLER 19,0 Nm). FITTING 5/8"(15,9 mm) Recessed Pendent Sprinklers 1 \ II FLUSH The Series TY-B Recessed Pendent 3/8±5/16" =1 1 I Sprinklers must be installed in accor- (9,5±7,9 mm) '% j + } dance with the following instructions. } / Step A.After installing the Style 15 or MOUNTING " 1/8 Style 20 Mounting Plate,as applicable, SURFACE (3,2 mm) over the sprinkler threads and with pipe-thread sealant applied to the pipe CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) threads,hand-tighten the sprinkler into TY-B PLATE 3/4 the sprinkler fitting. (19,1 mm) Step B.Tighten the sprinkler into the FIGURE 4 Step B. fitting using onln the into Wthe SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY(TY325) 7 Recessed Sprinkler Wrench (Figure WITH TWO-PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 3).With reference to Figure 1,apply the RECESSED ESCUTCHEON W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque 2-7/8" DIA. sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 (73,0 mm) Nm). FACE OF Step C.After the ceiling is installed or SPRINKLER —2-1/4" DIA. the finish coat is applied, slide on the FITTING (57,2 mm) Style 15 or Style 20 Closure over the 5/16±1/4" Series TY-B Sprinkler and push the (7,9±6,4 mm) 1/2"(12,7 mm) Closure over the Mounting Plate until FLUSH its flange contacts the ceiling. 1 I + Care and f I 1 MOUNTING ‘1101/8" Maintenance SURFACE (3,2 mm) The TYCO Series TY-B, 5.6 K-factor, --°--- Upright(TY315)and Pendent(TY325) CLOSURE SERIES MOUNTING 1-3/8"(34 ,9 mm) Sprinklers must be maintained and ser- TY-B PLATE 7/8"(22,2 mm) viced in accordance with this section. FIGURE 5 Before closing a fire protection system SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY(TY325) main control valve for maintenance WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 work on the fire protection system RECESSED ESCUTCHEON that it controls, obtain permission to shut down the affected fire protection Modified sprinklers must be replaced. The owner is responsible for the system from the proper authorities Sprinklers that have been exposed to inspection,testing,and maintenance of and notify all personnel who may be corrosive products of combustion, but their fire protection system and devices affected by this action. have not operated,should be replaced in compliance with this document, as Absence of the outer piece of an if they cannot be completely cleaned by well as with the applicable standards escutcheon, which is used to cover wiping the sprinkler with a cloth or by of the National Fire Protection Associa- a clearance hole, can delay sprinkler brushing it with a soft bristle brush. tion (e.g., NFPA 25), in addition to the operation in a fire situation. Care must be exercised to avoid dam- standards of any other authorities hav- The owner must assure that the age to the sprinklers- before, during, ing jurisdiction. Contact the installing and after installation.Sprinklers contractor or sprinkler manufacturer klers dam- regarding u any objects and that the sprinklers are aged by dropping, striking, wrench g 9 an Y questions. only cleaned by means of gently dust- twist/slippage, or the like, must be Automatic sprinklers are recommended ing with a feather duster; otherwise, replaced. Also, replace any sprinkler to be inspected,tested,and maintained non-operation in the event of a fire or that has a cracked bulb or that has lost by a qualified Inspection Service in inadvertent operation may result. liquid from its bulb. (Ref. Installation accordance with local requirements Section.) and/or national codes. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- Thereafter, annual inspections per sion must be replaced. NFPA 25 are required;however,instead of inspecting from the floor level, a Automatic sprinklers must never be random sampling of close-up visual painted, plated, coated, or otherwise inspections should be made. altered after leaving the factory. TFP152 Page 4 of 4 P/N* 77 - XXX - X - XXX I � SIN SPRINKLER TEMPERATURE FINISH RATINGS 570 5.6K UPRIGHT(1/2"NPT) TY315 1 NATURAL BRASS 135 135°F(57°C) 571 5.6K PENDENT(1/2"NPT) TY325 3 PURE WHITE(RAL9010)** POLYESTER 155 155°F(68°C) *Use suffix"I"for ISO 7-1 connection; SIGNAL WHITE(RAL9003) for example,77-570-4-175-I 4 POLYESTER 175 175°F(79°C) 9 CHROME PLATED 200 200°F(93°C) **Eastern Hemisphere sales only 286 286°F(141°C) 360 360°F(182°C) 000 OPEN*** ***OPEN indicates sprinkler assembly without Glass Bulb, Button,and Sealing Assembly TABLE A SERIES TV-B UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION Limited Ordering Warranty Procedure For warranty terms and conditions,visit Contact your local distributor for avail- www.tyco-fire.com. ability.When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-B Upright or Pen- dent(specify)Sprinkler, SIN (specify), K=5.6, Standard Response, (specify) temperature rating,(specify)finish, P/N (specify,refer to Table A) Recessed Escutcheon Specify:Style 15 Recessed Escutcheon with(specify*)finish, P/N(specify*) Specify:Style 20 Recessed Escutcheon with(specify`)finish, P/N(specify`) *Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 GLOBAL HEADQUARTERS 1400 Pennbrook Parkway,Lansdale,PA 19446 I Telephone+1-215-362-0700 Copyright CO 2014 Tyco Fire Products,LP. All rights reserved. two TEFLON is trademark of The DuPont Corporation. Fire Protection Products Eddyth read 40 A Lightweight Schedule 40 Replacement Pipe That Has a Corrosion Resistance Ratio of 1.0 Bull Moose Tube Company has been making pipe for a long time and is recognized as a producer of quality pipe products. Eddythread 40 is designed with the same thoroughness as our other fine pipe products and now our customers have an option to buy a carefully designed replacement for Schedule 40 that: • Has a Corrosion Resistance Ratio of 1.0 • Has a Pressure Rating of 300 psi • Is Lighter Weight Than Schedule 40 • Is Approved by Factory Mutual and Listed by Underwriters Laboratories • Is Produced in Accordance to ASTM A-135 and A-795 • Can be Used With Standard Schedule 40 Threaded Fittings, Couplings and Valves • Is Produced From Steel With Excellent Properties of Strength and Threadability • Can be Used in Wet, Dry, Preaction, and Deluge Type Sprinkler Systems* • Offers Lower Freight Costs EDDYTHREAD 40 SPECIFICATIONS NOMINAL PIPE SIZE arty ,VVEIGHT(lbsift) 1.D. Ort) BUNDLE SIZE 1 1.461 1.083 70 1 1/4 2.070 1.418 51 1 1/2 . 2.547 __ 1.654 _ 44 2 3.308 2.123 30 CORROSION RESISTANCE RATIOS NOMINAL I E tib SCHEDULE 40 EDDYTHREAD Kms.. 1 1.00 1.00 1 1/4 1.00 1.00 1 1/2 1.00 1.00 2 1.00 1.00 *Eddythread 40 can be hot dipped galvanized to meet FM's requirement for dry systems 6 1819 Clarkson Road For additional information, Chesterfield,MO 63017 contact your salesperson today at C UL us 8 BULL moosE Tues CONY (800)325-4467 (800)325-4467 or(636)537-2600 LISTED '--- FAX:(636)537-2645 in the USA,or from Canada IN ww.bullmoosetube.com call(800)882-4666 11> A vireo company e-mail:sales(a bullmoosetube.com APPROVED All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 8/08 C: 1.,., Ductile Iron Fittings- Class 300 UL/FM I Ott PLII$ C (2!1US 41> APPROVED A Fig. 35E 3-90°Elbow LISTED Size Part Number A PackingWeight in in •Inner Master lb 1117:4%_+� 1/2 35E 3004 1.13 100 200 0.2 - i '3/4 35E3006 1.31 ' = 70 - 140 0.3 A 1 35E 3010 1.50 40 80 0.5 nn 1-1/4 35E 3012 1;75 25'" .50: '0.8 n a 1-1/2 35E 3014 1.94 18 36 1.1 2 --:35E-3020 `<2.251`'10 , 20 r, 1.5 2-1/2 35E 3024 2.70f 4 8 �� 3.2 Fig. 35RE3-90°Reducing Elbow B , Size pert,Number' A S ` ' Packing Weight �� in .�r.. in�; in Inner Master lb I 3/4 x 1/2 35RE3006004 1.20 1.22 80 160 0.3 41"'k 1/2 - 359E3010004 '.;' 1.26 1.3 '` ' 70,' 140 0.4 A 1 x 3/4 35RE3010006 1.38 1.45 50 100 0.4 111. 14/4 X112 35863012004 1 1:34 1.5V 35a, 70 0.5 qlIl 1-1/4 x 3/4 35RE3012006 1.45 1.63 35 70 0.6 .:1-10: X'.1 . , 35RE3012010' „ ,.1.58 •, T 7 te m'39 ." 60 ' 0 7 1-1/2 x 1/2 35RE3014004 1.52 1.75 30 60 0.6 1-1/210 314;'.,', 35RE3014006; ., 1.52 ' 3j75 i;F,. 25 : 50 ->,:-• '0.7 '• 1-1/2 x 1 35RE3014010 1.65 1.80 20 40 0.8 1 1/2; ;1-1/f 35RE3b14012 µ 1.82 °:, 8 = '''1:8 x 36 ' 1.0 r 2 x 1/2 35RE3020004 1.60 1.97 18 36 1.0 2 X 3 350E3028405 , 1.60 -: i „1 0 a '18 �,.361 '1.;'1.0''''''' 2 x 1 35RE3020010 1.73 2.02 16 32 1.2 2.x;1= 4 35RE3020 12 . 1.40 a 21v .r` 12 .,' 24,,,; ..., 1.3'''. ktig 2 x 1-1/2 35RE3020014 2.02 2.16 10 20 1.5 x:2-1/2 x 171/2 3814E8024014_, 2.1:3 ,<,s,. '1'„2.51-1....... &5 .w. 12 Ht 2 2'': 2-1/2 x 2 35RE3024020 2.39 2.60 6 12 2.5 11 iT T 1 44 Fig. 35F 3-45°Elbow Size part Number A M Packing Weight 1-.;•:, '�A , "in m in Inner` Master '' -. lb , ::,:.:4 " / 1/2 35F 3004 0.88 150 300 0.2 Cir, ri ,.. 314 ;,35F.„3006 ::00 3006 ' p.98 160 0.3 135F 3010 1.13 40 80 0.5 141/4 : : ., 35F 3012 , " 1.29 25 50 0.7 �ii IA 1-1/2 35F 3014 1.44 20 40 1.0 t ,: 2'11 ,'X 35F 3020 1.69 14,- 20 1 6 2-1/2 35F 3024 1.95 4 8 2.7 Fig. 35T 3- Tee Size part Number A Packing Weight in in InnenMaster lb al�� A • 1/2 35T 3004 1.13 80 160 0.3 314 3513006 1.31 30,.. 0` 60 0.5 IP/ AI . III 1 35T 3010 1.50 25 50 0.7 I 1-1/4 -35T 3012 1.75 ,.10 -`" 20 1.1 A A 1-1/2 35T 3014 1.94 10 20 1.5 '` 2 35T 3020 2.25 '. 6 12 2.4 2-1/2 35T 3024 2.70 4 8 4.3 111 SMITH-COOPER INTERNATIONAL,® • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • wwwsrninccooper.com ISU ":# Ductile Iron Fittings- Class 300 UL/FM c01us APPROVED A Fig. 35CP3 -Straight Coupling with Ribs LISTED Size Part Number A , Packing Weight; inin. Inner Master lb ____ __ 1/2 35CP3004 1.38 200 400 0.1 6 .%.. 3/4 35CP3006 1.63 .,100 = ', 20Q,r-.; 0.2 1 35C P3010 1.75 60 120 0.4 1-1/4- 35CP3012 ,,"" x2.00 , 35.``, ' ;,70 0.5 1-1/2 35CP3014 2.19 25 50 0.7 - 35CP30201‘' is 2.62 ; 15 ' 30 A' 1.2.,. 2-1/2 35CP3024 3.00 9 18 2.2 Fig. 35RC3 -Hex Reducing Coupling 4- Size -T A 1'� , Packing ` Weight Part Number +N; sA in #t Inner Master x .f ib® 1 x 1/2 35RC3010004 1.69 80 160 0.3 1 x 3/4 3514C3010006 189 60,,. 0 nY 0,4 1-1/4 x 3/4 35RC3012006 2.06 40 80 0.6 ,2 x:'j(not Atex) 35Rc30211010 '.•y 2,81.,. , 20 s.: 40 , 10 Fig. 35HB3 -Hex Bushing ll , Size Part Number A "� Packing ' ''''' Weight B i*_ '" -.. in 4 Inner Master '' lb '- 1 x 1/2 35HB3010004 1 06 180 360 0 2 11,x3/4,,, ;35HB01.,•n6 1 180 `' 60' r 0.1 7 ��IIPIA 1-1/4 x 1 35HB3012010 1.19 90 180 0.2 i 1-1/2 x 1 u35HB3014Q10 1; 8.. >` i 75 a I}} 1-1/2 x 1-1/4 35HB3014012 1.25 75 150 0.3 4P1- i , .6. 2 x 1 351-183020010 1:38 ,%' 40 1 :2,,.1]...,' 2 x 1-1/4 35HB3020012 1.38 40 �80 0.6 2 X-4,-,1/266 35HB3020014 a ;- 1.38 ,,- _ 46 a , 80 ; 0.6 1 It: iFig. 35SP3 -Square Head Plug e A Packing .'-'4 'Weight viaPart Number in Inner Master �' lb 1/2 35SP3004 0.94 600 1200 0.07 A 3/4 t" 35SP3006 1:12 3 X ,0.1 1 � 1 35SP3010 1.25 20080' 400700 �� 0.1 1 '' 1-:1/4 35SP3012 ' 137 '..''. 109,. 'x200 "' ' 0.3 1-1/2 35SP3014 1.44 80 160 0.4 2 ',, 353P3020 1.50 _ 45 t } 0-6 Fig. 35U 3-Union with Brass Seat • A , Size Part Number A' - Packing Weight inin Inner ;! Master- lb ��' 1 35U 3010 2 19 20 40 1.0 1-1/4 35E13012 2.50 15 30 1,2. I 1-1/2 35U 3014 2.62 10 20 1.7 Low 2 35U.3020 3.12 6.; 12 <.2.4 .. 113 S\IITII-COOPER INTERNATIONAL' • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com Pipe Hangers Fig.200- "Trimline"Adjustable Band Hanger (B-Line Fig.B317ONF) (2)T01.1: O Fig.200F- "Trimline" Adjustable Band Hanger with Felt Lining (B-Line Fig.B317ONFF) c UL us Fig.200C- "Trimline"Adjustable Band Hanger with Plastic Coated (B-Line Fig.B317ONFC) Fig.200S - "Trimline"Adjustable Band Hanger with Non-Captured Nut urn Size Range: Fig.200 - 1/2" (15mm)thru 8" (200mm)pipe Material: Steel, Pre-Galvanized to G90 specifications io . Function: For fire sprinkler and other general piping purposes. Knurled u swivel nut design permits hanger adjustment after installation. Features: • (1/2" 115mm)thru 2" (5omm)) Flared edges ease installation for all pipe .v' types and protect CPVC plastic pipe from abrasion. Captured design __ ;I keeps adjusting nut from separating with hanger. Hanger is easily aB installed around pipe. , _ For hanger with non-captured nut order Fig. 200S. I' \, • (21/2" (65mm)thru 8" (2oomm)) Spring tension on nut holds it securely in / ` ` hanger before installation.Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" (15mm)thru 8" (200mm)) in the USA(UL)and Canada(cUL)for steel and CPVC plastic pipe and Fig.200-1/2.200-3/4 Factory Mutual Engineering Approved(FM) (3/4" (20mm)thru 8" (200mm)). Fig.2007to200-2 Fig.200-21/2 to 200-8 Conforms to Federal Specifications WW-H-171 E&A-A-1192A,Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69&SP-58, Type 10. Maximum Temperature: 650°F(343°C) Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Figure number and pipe size v Designed to meet or exceed requirements of :000.47 FM DS 2-0. " . Fig.200 Fig.200C Fig.200F Pipe Size Rod Size A B Approx.Wt./100 a=` Part No. in. (mm) in. (mm) in. (mm) lbs. (kg) 200-1/2 1/2" 115) 3/8"-16 31/8" (79.4) 25/8" (66.71 11 (5.0) 200-3/4 3/4" (20) 3/8"-16 31/8" (79.4) 21/z (63.5) 11 (5.0) 200-1 1" 125) 3/8"-16 33/8" (85.7) 25/B" (66.7) 12 15.51 # } • 200-11/4 11/4" 132) 3/8"-16 33/4 (94.0) 27/8" (73.0) 13 (5.9) 200-11/2 11/2" (40) 3/8"-16 37/8" (98.4) 27/8" (73.0) 14 (6.4) r ) 200-2 2" (50) 3/8"-16 41/2" (1143) 3" (76.3) 15 (6.9) 200-21/2 21/2" (65) 3/8"-16 55/8" (142.9) 41/8" (104.7) 27 (12.3) 200-3 3" (75) 3/8"-16 57/8" (149.1) 4" 1101.6) 29 (13.3) Fig.200S 200-31/2 31/2" (90) 3/e"-16 73/8" (187.3) 51/4" (133.3) 34 (15.6) 200-4 4" 1100) 3/0"-16 73/8" (187.3) 5" 1127.0) 35 116.0) 200-5 5" (125) 1/2"-13 91/8" (231.8) 61/4" 1158.7) 66 (30.2) 200-6 6" 1150) 1/2"-13 101/8" (257.2) 63/4" (171.4) 73 (33.4) 200-8 8" (200) 1/2"-13 131/8" (333.4) 83/4" (222.2) 136 (62.3) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. BQ Fire Protection Solutions -Line 21 by E:"f•N Threaded Accessories B3205 -Threaded Rod (right-hand threads - both ends) RoLco Fig.103) �� B3205L -Threaded Rod (right& left hand threads) '� Size Range: 3/8"-16 thru 3"-4 rod /� TL11111�1� Specify Length �. 1111 Material: Steel Function: Recommended for use as a hanger support in hanger assemblies. TL 1 Rod is threaded on both with shown. available with left and right handthreads-specify Fig.B3205L when ordering. -*V'll A Thread Size Maximum Temperature: 750°F(399°C) Finish: Plain.Contact B-Line for alternative finishes and materials. Order By: Part number, rod size, length and finish Standard Design Load Thread Size Thread Length TL 650°F(343°C) 750°F(399°C) Part No. A in. (mm) Lbs. (kN) Lbs. (kN) B3205-318 x'L' ;, ; 3/8"-16 21/2" (63.5) 730 (3.25) 572 (2.54) 83205-1/2 x'L' ' 1/2"-13 21/2" (63.5) 1350 (6.00) 1057 (4.70) B3205-511 x'12 ,. 5/8"-11 21/2" (63.5) 2160 (9.61) 1692 (7.52) 83205-3/411'L' 3/4"-10 3" (76.2) 3230 (14.37) 2530 (11.25) B3205-1/a x'L' T/8"-9 31/2" (88.9) 4480 (19.93) 3508 (15.60) B3205-1 x'L'' 1"-8 4" (101.6) 5900 (26.24) 4620 (20.55) 83205-11/a x'L' 11/8"-7 41/2" (1143) 7450 (33.14) 5830 (25.93) 93205-1114 X'L' w 11/4"-7 5" (127.0) 9500 (42.25) 7440 (33.09) 83205-11/2 X'L'=r 11/2"-6 6" (152.4) 13800 (61.38) 10807 (48.07) 83205-13/4 X'L' ''' 13/4"-5 7 (177.8) 18600 (82.73) 14566 (64.79) 83205-2 XV 2"-41/2 8" (203.2) 24600 (109.42) 19625 (87.29) 83205-21x4 X'L' - 21/4"-41/2 9" (228.6) 32300 (143.67) 25295 (112.51) 83205-21/2x'1',.„: 21/2"-4 10" (254.0) 39800 (177.03) 31169 (138.64) 83205-23/41'L' `' 23/4"-4 11" (279.4) 49400 (219.73) 38687 (172.08) 83205-3 x'L' _ 3"-4 12 (304.8) 60100 (267.32) 47066 (209.35) ATR-All Threaded Rod 120" (3.05m) Lengths (TOLCo Fig.100) - Fig. 99 -All Threaded Rod Cut To Length Size Range: 3/8"-16 thru 11/2"-6 rod in 120"(3.05m)lengths or cut to length ���^ 11,„, X1111. 9 9 i ���11�11111 Material: Steel � 1 H Maximum Temperature: 750°F(399°C) ao Finish: Plain.Contact B-Line for alternative finishes and materials. 4itifi' a v Order By: Part number, rod diameter and finish i=0 Part No.-Size x Length Threads Recommended Load Approx.Wt./100 Ft. ATR Fig.99 Per Inch Lbs. (kN) Lbs. (kg) ATR 1/41°X 120 99-1/4"x length 20 240 (1.07) 12 (5.44) ATR 3/8"x 120 99-3/s"x length 16 730 (3.24) 29 (13.15) ATR 1/2"x 120 99-1/2",x length 13 1350 (6.00) 53 (24.04) ATR 6/8"x 120 99-5/8"x length 11 2160 (9.60) 89 (40.37) ATR 3/4"X 120 : 99-3/4"X length 10 3230 (1437) 123 (55.79) ATR 7/e"x 120 99-7/s"X length 9 4480 (19.93) 170 (77.11) ATR 1"x120 99-1"x length 8 5900 (26.24) 225 (102.06) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. Pipe Hangers&Supports Revised B-Line 236 by E:T•111