Loading...
Report CI0cS J7)- fO1f wYAT T FIRE PROTECTION, INC. 9095 S.W. Burnham Tigard, OR 97223 RECEIVED JEVO TIMAY 302017 CITY OF TIGARD BUILDING DIVISION 16100 SW 72ND AVENUE PORTLAND, OREGON FIRE PROTECTION EQUIPMENT SUBMITTAL I- tLjCD Worldwide www.tyco-fire.com Fire Protection Contacts Products Series TY-FRB, 5.6 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General NOTICE The TYCO Series TY-FRB Sprinklers Description described herein must be installed and n maintained in compliance with this doc- The TYCO Series TY-FRB,5.6 K-factor, ument, as well as with the applicable . Upright(TY313) and Pendent(TY323) standards of the National Fire Protec- Sprinklers described in this data sheet tion Association,in addition to the stan- rte1 , are quick response,standard coverage, dards of any other authorities having . IP A i decorative 3 mm glass bulb-type spray jurisdiction.Failure to do so may impair sprinklers designed for use in light or the performance of these devices. a t F. ordinary hazard,commercial occupan- cies such as banks, hotels,and shop The owner is responsible for maintain- in their fire rotection s stem and ' ping malls. 9 p y devices in proper operating condition. The recessed version of the Series TY- The installing contractor or sprinkler FRB Pendent Sprinkler,where applica- manufacturer should be contacted with ble, is intended for use in areas with a any questions. finished ceiling.This recessed pendent ) sprinkler uses one of the following: Sprinkler • A two-piece Style 15 Recessed p Escutcheon with recessed adjust- ment up to 5/8 inch (15,9 mm) from Identification the flush pendent position. Number (SIN) • A two-piece Style 20 Recessed Escutcheon with recessed adjust- TY313 Upright 5.6K, 1/2"NPT ° ment up to 1/2 inch (12,7 mm) from TY323 Pendent 5.6K, 1/2"NPT the flush pendent position. The adjustment provided by the Technical Recessed Escutcheon reduces the Temperature Rating accuracy to which the fixed pipe drops Data 135°F(57°C) to the sprinklers must be cut. 155°F(68°C) Intermediate level versions of Series Approvals 175 FM, TY-FRB Sprinklers are described in UL and C-UL Listed 200 F(93 C) FM, LPCB,and VdS Approved 286°F(141°C) Technical Data Sheet TFP357. Sprin- kler guards and shields are described CE Certified Finishes in Technical Data Sheet TFP780. Sprinklers with Polyester Finish are UL Sprinkler:Refer to Table A and C-UL Listed as Corrosion-Resis- Recessed Escutcheon:White Coated, tant Sprinklers. Chrome Plated,or Brass Plated Maximum Working Pressure Physical Characteristics 175 psi(12.1 bar) Frame Bronze 250 psi(17.2 bar)* Button Brass/Copper *The maximum working pressure of 250 psi Sealing Assembly Stainless IMPORTANT (1.2 bar)only applies to the listing by Un- Steel w/TEFLON Always refer to Technical Data derwriters Laboratories,Inc.(UL). Bulb Glass Sheet TFP700 for the "INSTALLER Discharge Coefficient Compression Screw Bronze WARNING"that provides cautions K=5.6 GPM/psi1/2(80,6 LPM/bar1/2) Deflector Bronze with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 FEBRUARY 2014 TFP172 TFP172 Page 2 of 4 Components: *Temperature rating is ** Pipe thread connections per ISO 7-1 " 1 - Frame 4 - Bulb indicated on Deflector. can be provided on special request. 2 - Button 5 - Compression STYLE 15 or 20 3 - Sealing Screw ESCUTCHEON PLATE 1/2" 7/16"(11,1 mm) RECESSED Assembly 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON 6* I 1 ----- / 5 �_� 7/16" —R_ (11,1 mm) '■Fc q I NOMINAL 2" I� (I I MAKE-IN OA (50,8 mm) 1 T2 �. �` 2.' I � 1 11 1-3/8" 3 (50,8 mm) (34,9 mm) I 1 , 1, F / I WRENCH _—" 1 7 t t + - FLATS 1/2"NPT** DEFLECTOR* 2-7/8"(73,0 mm)DIA. _- CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT(TY313)AND PENDENT(TY323)SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE L, Operation Installation The glass bulb contains a fluid which The TYCO Series TY-FRB,5.6 K-factor, WRENCH RECESS expands when exposed to heat.When Upright(TY313)and Pendent(TY323) (USE ONLY the rated temperature is reached, the Sprinklers must be installed in accor- END"A") fluid expands sufficiently to shatter the dance with this section. glass bulb, allowing the sprinkler to activate and water to flow. General Instructions FIGURE 2 Do not install anybulb-type ype sprinkler if W-TYPE 6 the bulb is cracked or there is a loss SPRINKLER WRENCH Design of liquid from the bulb.With the sprin- kler held horizontally,a small air bub- WRENCH Criteria ble should be present. The diameter RECESS of the air bubble is approximately 1/16 The TYCO Series TY-FRB,5.6 K-factor, inch(1,6 mm)for the 135°F(57°C)and Upright(TY313)and Pendent(TY323) 3/32 inch(2,4 mm)for the 286°F(141°C) �,� Sprinklers are intended for fire protec- temperature ratings. /lam tion systems designed in accordance twith the standard installation rules rec- ognized by the applicable Listing or should be obtained by applying amin- Approval agency(such as, UL Listing imum to maximum torque of 7 to 14 is based on the requirements of NFPA ft.-lbs. (9,5 to 19,0 Nm). Higher levels �r� 13, and FM Approval is based on the of torque can distort the sprinkler Inlet PUSH WRENCH requirements of FM's Loss Prevention with consequent leakage or impairment IN TO ENSURE Data Sheets).Only the Style 15 or Style of the sprinkler. ENGAGEMENT 20 Recessed Escutcheon is to be used Do not attempt to compensate for WITH SPRINKLER for recessed pendent installations. insufficient adjustment in the Escutch- WRENCHING AREA eon Plate by under-or over-tightening FIGURE 3 the sprinkler. Re-adjust the position of W-TYPE 7 RECESSED the sprinkler fitting to suit. SPRINKLER WRENCH Upright and Pendent Sprinklers The Series TY-FRB Upright and Pen- dent Sprinklers must be installed in accordance with the following instructions. Step 1.Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. TFP172 Page 3 of 4 Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 2-7/8" DIA. 6 Sprinkler Wrench(Figure 2).With ref- (73,0 mm) erence to Figure 1,apply the W-Type 6 2-1/4" DIA. Sprinkler Wrench to the wrench flats. FACE OF ~- (57,2 mm) — Torque sprinklers 7 to 14 ft.-lbs.(9,5 to SPRINKLER 19,0 Nm). FITTING 5/8"(15,9 mm) Recessed Pendent Sprinklers 1 \ - FLUSH The Series TY-FRB Recessed Pendent 3/8±5/16" _ , I 7 I Sprinklers must be installed in accor- (9,5±7,9 mm) '/ / + } dance with the following instructions. } / + Step A.After installing the Style 15 or MOUNTING , 1/8" f Style 20 Mounting Plate over the sprin- SURFACE (3,2 mm) li kler threads, and with pipe-thread sealant applied to the pipe threads, CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) hand-tighten the sprinkler into the TY-FRB PLATE sprinkler fitting. 3/4"(19,1 mm) Step B.Tighten the sprinkler into the FIGURE 4 Step B. fitting using onln the W-Type SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY(TY323) 7 Recessed Sprinkler Wrench (Figure WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 3).With reference to Figure 1,apply the RECESSED ESCUTCHEON W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque 2-7/8" DIA. sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 (73,0 mm) Nm). FACE OF Step C.After ceiling installation and fin- SPRINKLER 2-1/4" DIA. fishing,slide on the Style 15 or Style 20 FITTING (57,2 mm) Closure over the Series TY-FRB Sprin- 5/16±1/4" - kler and push the Closure over the (7,9±6,4 mm) 1/2"(12,7 mm) Mounting Plate until its flange comes in + FLUSH contact with the ceiling. Care and t I 1,21MOUNTING �l� 1/8" Maintenance SURFACE (3,2 mm) The TYCO Series TY-FRB,5.6 K-factor, Upright(TY313) and Pendent(TY323) CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) Sprinklers must be maintained and ser- TY-FRB PLATE 7/8"(22,2 mm) viced in accordance with this section. FIGURE 5 Before closing a fire protection system SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY(TY323) main control valve for maintenance WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 work on the fire protection system RECESSED ESCUTCHEON that it controls, obtain permission to shut down the affected fire protection Modified sprinklers must be replaced. standards of any other authorities hav- systems from the proper authorities Sprinklers that have been exposed to ing jurisdiction. Contact the installing and notify all personnel who may be corrosive products of combustion, but contractor or sprinkler manufacturer affected by this action. have not operated,should be replaced regarding any questions. Absence of the outer piece of an if they cannot be completely cleaned Automatic sprinkler systems are rec- escutcheon, which is used to cover by wiping the sprinkler with a cloth or ommended to be inspected, tested, a clearance hole, can delay sprinkler by brushing it with a soft bristle brush. and maintained by a qualified Inspec- operation in a fire situation. Care must be exercised to avoid dam- tion Service in accordance with local The owner must assure that the sprin- age to the sprinklers before,during,and requirements and/or national codes. klers are not used for hanging any after installation. Sprinklers damaged objects and that the sprinklers are only by dropping, striking, wrench twist/ cleaned by means of gently dusting slippage,or the like,must be replaced. with a feather duster;otherwise, non- Also, replace any sprinkler that has a operation in the event of a fire or inad cracked bulb or that has lost liquid from vertent operation may result. its bulb.(Ref. Installation Section.) Sprinklers which are found to be leak- : eak The owner is responsible for the ing or exhibiting visible signs of corro- inspection,testing,and maintenance of sion must be replaced. their fire protection system and devices in compliance with this document, as Automatic sprinklers must never be well as with the applicable standards painted, plated, coated, or other- of the National Fire Protection Associa- wise altered after leaving the factory. tion (e.g., NFPA 25), in addition to the TFP172 Page 4 of 4 P/N* 77 - XXX - X - XXX � I SPRINKLER TEMPERATURE FINISH RATINGS SIN 1 NATURAL BRASS 135 135°F(57°C) 370 5.6K UPRIGHT(1/2"NPT) TY313 3 PURE WHITE(RAL9010)** POLYESTER 155 155°F(68°C) 371 5.6K PENDENT(1/2"NPT) TY323 q SIGNAL WHITE(RAL9003) POLYESTER 175 175°F(79°C) Use suffix"I"for ISO 7-1 connection; 9 CHROME PLATED 200 200°F93°C for example,77-370-4-175-I ( ) Eastern Hemisphere sales only 286 286°F(141°C) TABLE A SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION Limited Ordering Warranty Procedure For warranty terms and conditions,visit Contact your local distributor for avail- - www.tyco-fire.com. ability.When placing an order,indicate the full product name and Part Num- ber(P/N). Sprinkler Assemblies with NPT Thread Connections Specify:Series TY-FRB Upright or Pen- dent(specify)Sprinkler, SIN (specify), K=5.6,Quick Response,(specify)tem- perature rating, (specify) finish, P/N (specify,refer to Table A). Recessed Escutcheon Specify:Style 15 Recessed Escutcheon with(specify')finish, P/N(specify*) Specify: Style 20 Recessed Escutch- eon with(specify*)finish,P/N(specify) *Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 GLOBAL HEADQUARTERS 1 1400 Pennbrook Parkway,Lansdale,PA 194461 Telephone+1-215-362-0700 Copyright m 2014 Tyco Fire Products,LP. All rights reserved. tyco TEFLON is trademark of The DuPont Corporation. Fire Protection Products Eddythread 40 A Lightweight Schedule 40 Replacement Pipe That Has a Corrosion Resistance Ratio of 1.0 Bull Moose Tube Company has been making pipe for a long time and is recognized as a producer of quality pipe products. Eddythread 40 is designed with the same thoroughness as our other fine pipe products and now our customers have an option to buy a carefully designed replacement for Schedule 40 that: • Has a Corrosion Resistance Ratio of 1.0 • Has a Pressure Rating of 300 psi • Is Lighter Weight Than Schedule 40 • Is Approved by Factory Mutual and Listed by Underwriters Laboratories • Is Produced in Accordance to ASTM A-135 and A-795 • Can be Used With Standard Schedule 40 Threaded Fittings, Couplings and Valves • Is Produced From Steel With Excellent Properties of Strength and Threadability • Can be Used in Wet, Dry, Preaction, and Deluge Type Sprinkler Systems* • Offers Lower Freight Costs EDDYTHREAD 40 SPECIFICATIONS N0 NAE plpESlz in) wEIGHT obsift) i.D On ¢ BUNDLE SIZ 1 1.461 1.083 70 1 1/4 2.070 1.418 51 1 1/2 2.547 1.654 44 2 3.308 2.123 30 CORROSION RESISTANCE RATIOS NOMINAL PIPE SIZE(in) SCHEDULE 48 ;' EDDYTHREAD 40 1 1.00 1.00 1 1/4 1.00 1.00 1 1/2 1.00 1.00 2 1.00 1.00 *Eddythread 40 can be hot dipped galvanized to meet FM's requirement for dry systems 1819 Clarkson Road For additional information, Chesterfield,MO 63017 contact your salesperson today at C �L usAtk BULL MOOSE TUBE COMPIANY (800) (800)325-4467 or(636)537-2600 �ar�u — ' FAX:(632536)447 537-2645 in the USA,or from Canada www.bullmoosetube.com call(800)882-4666 41C: A CCRPRRQ company e-mail:sales a,bullmoosetube.com APPROVED All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 8/08 n ' - Ductile Iron Fittings- Class 300 UL/FM _ c (Z)) us ' APPROVED Fig. 35E 3-90° Elbow LISTED A Size A PackingWeight Part Number 4 in in Inner Master lb Il _ + 1/2 35E 3004 1.13 100 200 0.2 _�2/4 35E 30053.:- 1.31 , 70 777 140'77 0.3"111110/0 I i A 1 35E 3010 1.50 40 80 0.5 fi F- � F�as� r n .Ay Milli �, 1:1/4 ''35E 3012, . ,. 1.75 7 25. `x 0.8 1-1/2 35E 3014 1.94 18 36 1.1 .;gr 2 ,>. 3 E 3020+'. ..?,:!.25 ` y 10 Nx,P. ', 20 „ 1.8 2-1/2 35E 3024 2.70 4 8 3.2 Fig. 35RE3-90°Reducing Elbow B > ,Size A: A B Packing -, Weight Pa Number 4 F___.�,, in ., ,' �in in , Inner Master lb N 3/4 x 1/2 35RE3006004 1.20 1.22 80 160 0.3 'Ii 11<1/ 35RE301••• 1.26 4 1..36 t70 ."1`01 •4 1 x3/4 35RE3010006 1 38 1 45 50 100 0.4 �.4 114 'I(2 '''....50.4..91 i•, .: a r 1-1,,,x 3/4 35RE3012006 1.45 1.63 35 70 0.6 V; 1..',24 --1:1 x5RE3201 1.;. . t,._ . ...rt60 ,:',2.,......, 01 1-1/2 x 1/2 35RE3014004 1.52 1.75 30 60 0.6 1-1/gx 4: : 35REQ14• !.I;: 1;52 , x,.175 , X25. "s 1+ „ Of;'. 1-1/2 x 1 35RE3014010 1.65 1.80 20 40 0.8 1112 i 1/ ;,3 30 f•12 4 ,j.82 . 188 x .'1: 36. 41,1.0 2 x 1/2 35RE3020004 1.60 1.97 18 36 1.0 2 44 35RE3 , ,,,,kF60 ,'c1.97„,,, -M 1 §`. . i: .,-x1.0 11 2 x 1 35RE3020010 1.73 2.02 16 32 1.2 al.x 114 r1 3IE30 12 ,.M. '''y 1,90 . f,.,: 2.10 -1' 1 ;;M: 3.iw: 2 x 1-1/2 35RE3020014 2.02 2.16 10 20 1.5 ;14t1 �x2-1)x 1-112 5RE30240142.1k,w # 12 ''.4-...... 2,2; 2-1/2 x 2 35RE3024020 2.39 2.60 6 12 2.5 �z^ Fig. 35F 3-45°Elbow A Size Part Nmber A Packing f '=Weight �t in �`. Inner Master w. b'. 1/2 35F3004 0.88 150 300 0.2 I 3/ ," 5F Q08 ;a 0.98 t> .. 801 35F3010 1.13 40 80 0.5 1/4 3F 3(k'i . , ':29 25 56�i� IA 1-1/2, 35F3014 1.44 20 40 10 r. ti 35F 2 :',.,1769 r 10 , � 1; x 2-1/2 35F 3024 1.95 4 8 2.7L Fig. 35T 3- Tee i*,4 Size' Par Nu ber' ,"µx Packing ~, ; Weight in x in '.� Inner " .,_.Y Master h,, Ib"' aMl4 IA1/2 35T 3004 1.13 80 160 0.3 35T ®•. - X331 r3[1 '.- 60 { 0.a 1 351 3010 1.50 25 50 0.7 I� �I 4.T-1-y4, 35t 39#1 "x 1t 5 .i0 201;,..'''..! 1 A A1-112 35T 3014 1.94 10 20 1.5 g 2; " 35T1 020 , . 2.20,. '4" 5;., , .£4 -1#-.'• 4 2-1/2 35T 3024 2.70 4 8 4.3 111 SMITH-COOPER INTERNATIONAL' • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com `._= Ductile Iron Fittings- Class 300 UL/FM .F: M j Q444412' 4' C 00us '® APPROVED Fig. 35RT3-Reducing Tee LISTED Size : " A: B C ,.Packing Weight Na in Part Number :n ,� in .[n in Inner Master lb I C 3/4 x 1/2 35RT3006004 1 20 1.20 1 22 60 120 0.4 _ i I , x 1/2 144 35RT301f 904 , 126 1..26 1.36 39 '''' 60 0.6 1 x 1/2 x 1 35RT3010004010 1.50 1.36 1.50 30 60 0.6 i t44x3/4 r 1' 35AT3010Q,9e ,1.38 138 x....1.45 =25 ,,m `53„ ,,..0.6 . a B A 1 x 3!4 x 3/4 35RT3010006006 1.38 1.31 1.45 35 70 0.6 x 0;4x1 ,355RT30101( 010,,...,,,1.56..„0 1�r; 1 0 .,, '•' 0 0,7,. 1-1/4 x 1/2 35RT3012004 1.34 1.34 1.53 20 40 6:8 1-1441/ 014 ,35RT301 40 2 1.75 1, 1,53,,,',..„1.7&'''',„',A,25'..1":`,,,,, 50 ; ..0.S`,, 1-1/4 x 3/4 35RT3012006 1.45 1.45 1.62 15 30 0.9 4 35RT3012006612 1.75 1:62 1 76 '" 20 1-1/4 x 1 35RT3012010 1.58 1.58 1.67 15 30 1.0 ' 1,4x 1, 35RT301",35080:1101.9:0154,,,4,1 34. :1.g.§1i _1.541/4,:444 2,,644""a.4 Q .144 0.7;.. 1-1/4 x 1 x 3/4 35RT3012010006 1.45 1.38 1.63 20 40 0.8 141-414:x ii 25RT t112 100' . f.:40 158 1 49 40 0.9 �_ w 1-1/4 x 1 x 1-1/4 35RT3012010012 1.75 1.69 1.75 15 30 1.0 1-12 35 30`'400 $44 101 Al 65 alti ' ..,••82 .,, 1.0-1 0 r, 1 1/2 x 1/2 x 1-1/4 35RT3014004012 1.81 1.56 1.88 24 48 1.1 T`1/2xJ2 1-1 3R1`14vo46114. f:64" ' ".1.66 T.94 94 ..I , 24 1.2 1 1/2 x 3/4 35RT3014006 1.52 1.52 1.75 16 32 1.1 1- 'x3/4x '1/4 13 `30.4.. 112n).941, x"1.60- ,1:- } 2f.' 40 4T 1-1/2 x 3/4 x 1-1/2 35RT3014006014 1.94 1.75 1.94 18 36 1.2 r1h -112 x 1 ' , ,k, . -T.40 -,11.65...:''''1.65 1..a` 1*` 24 '1. 1-1/2 x 1 x 1/2 35R13014010004 1.44 1.25 1.69 20 40 0.8 y 1 tix'I x 37 . , -714p1 406, =5Q 1.44` x°75 -16i"� °32^" '0::6'1' 1-1/2 x 1 x 1 35RT3014010010 1.65 1.50 1.80 16 32 1.0 ,,,,,,a21/:, 1 `i,#1/4".„ . iT 14C 1 1 2 1767i" ' � 4 724 vm 1-1/2 x 1 x 1-1/2 35RT3014010014 1.94 1.80 1.94 12 24 1.3 1-1Dk f21/4.,,A,; 35F014012 2W :17e2 ; 8 n.12; '' 24Y:4 1-1/2 x 1-1/4 x 1/2 35RT3014012004 1.41 1.34 1.66 16 32 0.9 1 v1, -x" /4,'r #/4 35RT30140 06„ 1.5221-1.4w '-',1;t616 .02 '''w'14f 1-1/2 x 1-1/4 x 1 35RT3014012010 1.65 1.58 1.80 16 32 1.1 r 1 112 x 14/4 1 1 f `3RT3014012Q12 .1 1.82- 1,, 51 ` 1" , , ' 1 1-1/2 x 1-1/4 x 1-1/2 35RT3014012014 1.94 1.88 1.94 14 28 1.4 ,x „ ;.:. r "0-4 :14 '1.,4 .,.1, 1 ti' 1O..,r 20 -1,,,C: 2 x 3/4 35RT3020S06 1.60 1.60 1.97 10 20 1.6 1r2 x 1 9:43(44'1-3.0.PP. 1.73R 73 }' .02*„..5::8 16 � '''',.'''1'..%4-.:7": 2 x 1 x 2 35RT3020010020 2.25 2.02 2.25 8 16 1.9 x 17)143' $3 T3k Obit, 1.90 „11,„„90 w 1210 =8 16 r 1#,9 %^' 2 x 1-1/4 x 2 35RT3020012020 2.25 2.10 2.25 8 16 2.0 x 1 i/2 ' ,302'0014xr 2.02 . 2;02,4 2-16 S 16' .. 1 4443 2 x 1-1/2 x 1/2 35RT3020014004 1.49 1.41 1.88 10 20 1.3 2 x 1/2 x 3/4 y ;RT*20014006. 1.66' 1.S2 1.97 ,,!,4020 , _ 2 x 1-1/2 x 1 35RT3020014010 1.73 1.65 2.02 8 16 1.5 � ,2x /2x1-1f4' R' 21014012 1,93 4.2 `x.10f 16 „`1/7 2 x 1-1/2 x 1-1/2 35RT3020014014 2.02 1.94 2.16 8 16 1.8 Fig. 35BT3-Bull Head Tee Size .� :' �� A B 4-C Packing Weight �, Part Numher ,.. �,.1i� in 1n "1n 1n Inner Master, �tb . 3/4 x 1 35BT3006010 145 1.45 137 30 60 0.6 _ IC 1 x171/4 , ` 351bT3010Q12 ,141167.' '4.67 ';. '...6....' ,20 40 , ,0.9 x n# -�-_ 1 x 1-1/2 F1x.1-1/ 35BT3010014 1.80 1.80 1.65 15 30 1.0 ra. E A ,F B , 1-1/4 x 23 3 T301201..0014' 1.0.6 1,10?' 1, ,: 15 20 1. 1,2 1-1/4 x 1-1/2 35BT3012014 1.88 1.88 1.82 15 30 1.3 :1.1/4 x 2 '''''''35BT301,202( '' 2,10 ;'2;1011.0 a 10 T 20 1.6 1-1/2 x 1-1/4 x 2 35BT3014012020 2.16 2.10 2.02 10 20 1.8 y,- 14/2 x2 'tc.8T 014020, , 2.16 2,16. 2.0z fr , ;16 t,,,,,,- i# .. SMITH-COOPER INTERNATIONAL' • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com 112 CARBON..7: 7777STEEL_PIPE CUT_PRODUCTS _ *F FireLock® - c©ua <> vas LPCB ...SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLE 922 The Style 922 Outlet-T provides a convenient method of incorporating'h,3/4,and 1"/15,20 and 25mm outlets for directly connecting sprinklers,drop nipples,sprigs,gauges,drains and other outlet products.Available for 1'/4 through 76.1 mm/32 to 76.1 mm piping systems,Style 922 outlets are UL/ULC Listed,LPCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. fir The locating collar engages into the hole prepared in the pipe.When tightened,the assembly compresses the gasket onto the OD of the pipe.The Style 922 Outlet-T is UL/FM rated up to 300 psi/2068 kPa and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard,lightwall,Schedule 5 and other specialty pipes.* Contact Victaulic for other optional coatings. *Consult Section 10.01 for specific listings/approvals. MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536,grade 65-45-12.Ductile iron conforming to ASTM A-395,grade 65-45-15, is available upon special request. Gasket: • Grade"E"EPDM-Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc.and Approved by Factory Mutual Research for wet and dry(oil free air)sprinkler services up to the rated working pressure using the Grade"E"Type A Gasket System. Bolts/Nuts:Heat-treated plated carbon steel,trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Housing Coating: • Orange enamel(North America, Latin America,Asia Pacific) • Red enamel(Europe) JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. /CtaUiiC.--- REVD 1o.sz1 IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS 10.52 Firt,o1,,/s''' OutletT STYLE 922 Nominal Size Hole Approx. Dimells.",-inches/millimeters -- ' ' - - - DIMENSIONS Y Z--1 r . 1321/4 I i u'nc FAh inches/mm liT r n 1;11/25 : 4:0°;*00°3306/.1141:05 Ta 1.V83 1.10 3.87 V 6.75.3_.Z.c 0.65 33.0 3 87 2.56 Wei,g071.1h..54.t105Ea.11 _ 0 3/4 • V 2.....„ .,..,...s. 20 I ...TOL As.:,:i 4 P. 1 1330/.2,66 3112..23580 42416.68;8355 2211.7.711..0909 0.9,95.88..,3733 2 56 01.5.24 1 3/16 1.52 6.0 30.2 38.6 55.4 27.9 -8 2.56 1.2 25 • WIP)F1' VVI 121 Y2 9 1.22 4.08 1 3/16 1.42 1.5 31.0 103.6 65.0 0.54 1 1/2 15 30.2 36.1 493 2.56 1.2 40 3/4 1 3/16 1.40 1.95 1.22 4.08 0.54 49.5 31.0 103.6 65.01 3 1 20 1330/.126 31.5646 2.30 17.1202 140.0386 625.5.06 0.5.9 41.7 58.4 i' 2.56 1.3 2 0 ,5 1330/126 1.66 2.19 1.46 .'11-1.:8 65.0 0.59 2 x 15 30.2 42.2 55.6 , 37.1 50 1.4 1.64 2.19 1.46 ,,.1.:08 625'5.06 0.64 3/4 1 3/16 55.6 37.1 ' 1.5 1 20 1330/.126 41.7 25 1 3/16 1.91 2 44 14;14 137.2 65.0 U./ 30.2 41.78.88 64.52.54 37.11.46 1541..46608 262.5.55606 0.2.6_638 26'51/2 X ir; 30.2 41.88.95 26.24.40 1.71 15:2 625.5.06 0.731.6 48.0 62.0 43.4 203/4 1330/.21 6 1 13/16 54.12.13270.799 413,2.41 137.25.4026. 06 1.6 . 30.2 0.73 25 , 1/2 1 3/16 1.91 2.44 1.71 5.50 625.5.06 , 0.731.6 76.1 torn X 15 1 30.2 48.5 62.0 43.4 139.7 1 20 i 330/.216 415.8.09 2. 622.74.904 1 411.377.411 55.5500. 22‘.5566 0.800.7311.76 ; 54.1.31 70.9 43.4 139.71397 65.065.0 1 1 3/16 2 - 25 , 30.2 foruse with this Victaulic product.Failure to verify threadsfema i ethreaded productsmale harreeaddeesdiggnregdd gtoctascwcol tmh ms goedcai atlef estaat nu dr easr,ds uNcPhTaosr gBrSoPbTe(so,optional)pen- de , aeln)- mt Victaulica ale epipe stintatbsiplitriyniknleards,veatncc.,eshmoauyldrebseglyteinrifaiessdeamsbsulyitparboleblemsor leakage. *Center of run to engaged pipe end for NPT threads(dimensions are approximate). ..--- www.victaulic.com \/.actaulie VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED 10,52 2 REV G IPS CARBON STEEL PIPE- HOLE CUT PRODUCTS 10.52 (R) FireLock Outlet-r STYLE 922 • PERFORMANCE Equivalent Length of 1 inch Schedule 40 Steel Prue(per UL Run Size n Outlet Size 213,Section 16)(C,--120)*,FT Inchestnim Feet/meters 1 X 2518.5 322.6 1½ 1 8.5 X 40 25 2.6 2 X 1 8.5 50 25 2.6 21/2 X 1 j 8.5 65 25 2.6 1 8.5 76.1 mm X 25 2.6 *Hazen-Williams coefficient of friction is 120 www.victaulic.com ‘/CtaUlie VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.02009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. REV G 10523 t�v Fi ") Outlet STYLE 922 INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing.Handbooks are included with each shipment of Victaulic products for complete installation and assembly data,and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. • For complete contact information,visit www.victaulic.com 10.52 3355 REV G UPDATED 12/2009 ictaullc VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 10.52 VERTICAL MOUNT SAMMYS ' SAMMYS° for Wood Not less than Wood Flooring 2"nominal width Product Features (1-1/2") ! I—/ 4 •No pre-drilling required. Not less than •Quick to install using the Sammy 13°nominal thickness(2-1/2°) Nut Driver with an 18V cordless (depth or side Wood Joist drill/driver. of vertical member) •Saves time from traditional Double Sheeftock 4 methods. .. . Ceiling For vertical use- q install in center of lover face. I.° •Reduces installation cost. btnimum 2°embedment into base material for NFPA 13 compliance. Composite I Truss •Made in the U.S.A. Consult truss manufacturer for "t t recommended instslation point fi. 'Pre-willing may be required for GST 25-380.Tooi avaf�ble ortpage 10. A. Approvals Rod Part Model Screw Ultimate UL Test FM Test Box Case Size Number Descriptions Pullout(lbs) Load Obs) Load(lbs) Qty Qty s. — 1/482957 x .1.,...,T 100 , 1/4x1"' 210(7/16"OSB) '° " " 25 12r: �.r '? w 670(3/4:Ply) .,. I 1/4" 8003957 GST 200 1/4 x 2" 1760(Fir) 25 125 =11, '.,,)004957 T .GST 300 i;: 1/ x3" 2060(Fir", ,` a'<'-, 25 ';',1 *- 3/8" 8006957 GST.75 1/4 x 3/4" 564 (3/4"Ply) 25 125 '' ., ,' 3/8" 8007951 GST 10 1/4 x 1'„"" 210(7116"OSB} 300 " 125 ,' 4v'_ ,,4. `, ., 87°,(3/4"311) `.a. , ..,�. • ' , — �7 3/8" 8008957 GST 21 1/4x2" 1760(Fir) 850 1475 25 125 3/8" 8068925 GST 07,ss ;C"1/4x2" 1760(Fir) 850 "13;7 'ri522, '125 3/8" 8009925 GST 25-380 3/8 x 2-1/2" 2113 (Fir) 1500 25 125 /P- ' tz.3/8 ,�8,01t057''' GST 30 1/4x3" `' ; 2060(F *,-- 1500 1475 2i'. '".*'''' 125;,* #14 Black Q Nut Driver 3/8" 8069925 GST 30-SS 1/4 x 3" 2060(Fir) 25 125 Part#8113910 3/8 ` 6011925 GST 4011,1i1" 2180:1W*, 25 ".',1 3/8" 8012925 GST 60° 1/4 x 6" 2230(Fir) 25 125 :04.3i,,--8013925 ` GST 2 : , 114 x 2" 1760(Fir) * '• -� 25 1125"'. — 1/2" 8014925 GST 2.5-380 3/8 x 2-1/2" 2113 (Fir) 25 125 "12" . 8015925 " GST3 114x3. 15 r _< _ X 25 125 — 1/2" 8016925 GST 4 1/4 x 4 2180(Fir) 25 125 r 1/2" ' 8017925 GST6 -, ; 1/416" f 2230(Fir} :,. %. ,, >f: '25': 1i" #14 SW Red Nut Driver Part#8114910 SAMMY Swivel Head' for Wood Product Features •Eliminates distortion of threaded rod. •Saves time from traditional methods. Illiii •Accommodates up to 3'/a"x 12 pitch roof. •Reduces installation cost. •Allows 17°deflection from vertical. •Made in the U.S.A. Approvals Rod Part Model Screw Ultimate UL Test FM Test Min Box Case Size Number Descriptions Pullout Obs) Load(lbs) Load{lbs) Thickness Qty Qty u^ C ,*„.**,i....*'13/8'' 8139957" 'SH-GSB 20 1/4,,x 2 1257 "' `' 1050'-:,, ;1475 25. ;.K;i.125' 125 3 4.' 3/8" 8141957 SH-GST 30 1/4 x 3" 1720(Fir) 1500 1475 25 125 #14 Black Nut Driver SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time.When the face of the driver comes into part#8113910 contact with the material you are installing into,continue drilling until nut driver spins free.Installation is then complete.Warranty requires the use of the appropriate nut driver for installations. 0 w (pis For the most up to date information,visit www.sammysuperscrew.corn 4 Threaded Accessories B3205 - Threaded Rod (right-hand threads - both ends) (TOLCO Fig.103) �\., B3205L - Threaded Rod (right& left hand threads) TLSA�� �� Size Range: 3/8"-16 thru 3"-4 rod Specify Length 1��� 'L' Material: Steel Function: Recommended for use as a hanger support in hanger assemblies. TL -1 th Rd is threaded on b ends th available with left a do right handithr ads-specify Fig.B3205L w en oright hand threads of the lengthorderi 91so r\\111 A Thread Size Maximum Temperature: 750°F(399°C) . Finish: Plain.Contact B-Line for alternative finishes and materials. Order By: Part number, rod size, length and finish r Standard Design Load Thread Size Thread Length TL 650°F(343°C) 750°F(399°C) Part No. A in. (mm) Lbs. (kN) Lbs. (kN) ,B3205-3/8 x'L'11 3/8"-16 21/2" (63.5) 730 (3.25) 572 (2.54) B3205-1/2x'Vt.°°;,. 1/2"-13 21/2" (63.5) 1350 (6.00) 1057 (4.70) *3208-5/8 it' -- 5/8"-11 21/2" (63.5) 2160 (9.61) 1692 (7.52) 1 ti Jtit'il 3/4"-10 3" (76.2) 3230 (14.37) 2530 NM ,03206-7/a X11.1 s„ 7/8"-9 31/2" (88.9) 4480 (19.93) 3508 (15.60) B3205-1;. 'Lilt . 1"-8 4" (101.6) 5900 (26.24) 4620 (20.55) 83205-11/8 x'L' = 11/8"-7 41/2" (114.3) 7450 (33.14) 5830 (25.93) • B3205-14 x'L' 11/4"-7 5" (127.0) 9500 (42.25) 7440 (33.09) I"-.1/2 X' ' 11/2"-6 6 (152.4) 13800 (61.38) 10807 (48.07) • B320545/4 x'L' 13/4"-5 7" (177.8) 18600 (82.73) 14566 (64.79) 05-2 x'L' 2"-41/2 8" (203.2) 24600 (109.42) 19625 (87.29) 03205-21/4 x'Lt. 21/4"-4112 9" (228.6) 32300 (143.67) 25295 (112.51) B3205-21/2`x'L' 21/2"-4 10" (254.0) 39800 (177.03) 31169 (138.64) 133205-28/4 x'L' - 23/4"-4 11" (279.4) 49400 (219.73) 38687 (172.08) `03205-3 X'L'„s ' 3"-4 12" (304.8) 60100 (267.32) 47066 (209.35) ATR-All Threaded Rod 120" (3.05m) Lengths (TOLCO Fig.loo) Fig.99 -All Threaded Rod Cut To Length �� � ; Size Range: 3/8" 16 thru 11/2"-6 rod in 120"(3.05m)lengths or cut to length a ����l',1110" ',;������1�11��11111 Material: Steel ll�����1�11" Maximum Temperature: 750°F(399°C) ^'' Gni'i Finish: Plain.Contact B-Line for alternative finishes and materials. din Order By: Part number, rod diameter and finish $ 4 Part No.-Size x Length Threads Recommended Load Approx.WtJ100 Ft. ATR Fig.99 Per Inch Lbs. (kN) Lbs. (kg) kill/4.1120'i 99-1/4"x length; 20 240 (1.07) 12 (5.44) ATA 3/s"x 120., 99-3/8"xtlength`` 16 730 (3.24) 29 (13.15) A1I1,1/2"X 120' ;99-1/2"x length,,„ 13 1350 (6.00) 53 (24.04) • r'ATR 5/a";x 120 99-5/s"x length 11 2160 (9.60) 89 (40.37) ATR 3/4"X,1 20 .; x 99-3/4"X length: 10 3230 (14.37) 123 (55.79) ATR Y/e" 120 10=1 9 4480 (19.93) 170 (77.11) • ATR 1"X 120 ti' 99-1"x length,; 8 5900 (26.24) 225 (102.06) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B- Pipe Hangers&Supports Revised4/29/2014 Line 236by E'A•M Pipe Hangers • ®ToLc:a- r. Fig"200- "Trimline"Adjustable Band Hanger (B-Line Fig.B317ONF) Fig.200F- "Trimline"Adjustable Band Hanger with Felt Lining (B-Line Fig.B317ONFF) Fig.200C- "Trimline"Adjustable Band Hanger with Plastic Coated (B-Line Fig.B317ONFC) CC LISTE Fig.200S - "Trimline"Adjustable Band Hanger with Non-Captured Nut 11> Size Range: Fig.200 - 1/2" (15mm)thru 8" (200mm)pipe Material: Steel, Pre-Galvanized to G90 specifications s Function: For fire sprinkler and other general piping purposes. Knurled �� swivel nut design permits hanger adjustment after installation. ��. Features: _ \\ k.• (1/2" (15mm)thru 2" (50mm)) Flared edges ease installation for all pipe ,f=` types and protect CPVC plastic pipe from abrasion. Captured design _+_ ;I keeps adjusting nut from separating with hanger. Hanger is easily ne installed around pipe. , For hanger with non-captured nut order Fig. 200S. A j' • (21/2" (65mm)thru 8" (20omm)) Spring tension on nut holds it securely in \` hanger before installation.Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" (15mm)thru 8" (20omm)) in the USA(UL)and Canada(cUL)for steel and CPVC plastic pipe and Fig.200 /2.200-1/2 Factory Mutual Engineering Approved(FM) (3/4" 120mm)thru 8" (200mm)). Fig.2001to200-2 Fig.200-21/2 to 200-8 Conforms to Federal Specifications WW-H-171 E&A-A-1192A,Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69&SP-58, s+. Type 10. Maximum Temperature: 650°F 1343°C) Finish: Pre-Galvanized. Stainless Steel _ materials will be supplied with (2) hex nuts in place of a knurl nut. of To Order By: Figure number and pipe sizey Designed to meet or exceed requirements of FM DS 2-0. .. Fig.200 Fig.200C Fig.200F Pipe Size Rod Size A B Approx.Wt./100 .,. Part No. in. (mm) in. (mm) in. (mm) lbs. (kg) 200-1/2 1/2" 115) 3/8"-16 31/a" (79.4) 25/a" (66.7) 11 (5.0) r . 1 200-3/4 3/4" 1201 3/8"-16 31/8" (79.4) 21/7 (63.5) 11 (5.0) /' t 200-1 1° 125) 3/8"-16 33/8" (85.7) 25/8" (66.7) 12 15.5) ",x7 200-11/4 11/4" (32) 3/8"-16 33/4" (94.0) 27/8" (73.0) 13 (5.9) i 200-11/2 1112" (40) 3/8"-16 37/8" (98A) 27/8" (73.0) 14 (6.4) 41 200-2 2" (50) 3/8"-16 41/2" (114.3) 3" (76.3) 15 (6.9) 11 200-21/2 21/2' (65) 3/8"-16 55/8" (142.9) 41/8" (104.7) 27 (123) 200-3 3" (75) 3/8"-16 57/8" (149.1) 4" 1101.6) 29 (13.3) Fig.200S 200-31/2 31/2" (90) 3/8"-16 73/8" (1873) 51/4" (1333) 34 (15.6) 200-4 4' (100) 3/8"-16 73/8" (187.3) 5" 1127.0) 35 (16.0) 200-5 5 (125) 1/2"_13 91/8" (231.8) 61/4" (158.7) 66 (30.2) 200-6 6" (150) 1/2"-13 101/8" (257.2) 63/4' 1171.4) 73 (33.4) ! 200-8 8" 1200) 1/2"-13 131/8" (333.4) 83/4" (222.2) 136 (62.3) x All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. Fire Protection Solutions 21 B-Line by Fii a