8P8 4s 9s Ei SCOPE OF WORK SITE RF4Cg INSTALL A NEW SPRINKLER MONITORING SYSTEM WHICH INCLUDES SPRINKLER W FLOW AND TAMPER VALVE MONITORING, CENTRAL STATION OFF-SITE REPORTING, A MANUAL PULL STATION, AND SMOKE DETECTOR. ' ` �f17 1 GENERAL NOTES < on OF- GAiv illtillii „ 1. THE ARE ALARM SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 72 AND NFPA 70, ARTICLE 760, POWER LIMITED SYSTEMS. a �\ VI 2. ARE ALARM WIRE INSTALLED IN VERTICAL RUNS AND PENETRATING MORE z Fn �n THAN ONE FLOOR SHALL BE RISER RATED. n �p 3. FIRE ALARM WIRE RUN IN DUCTS OR PLENUMS SHALL BE PLENUM RATED. BY OTHERS �I 1 �_ 4. ONLY SYSTEM WIRING CAN BE RUN IN THE SAME CONDUIT. �Q4- 14 - q -� I lit III - 5. A SYSTEM GROUND MUST BE PROVIDED FOR EARTH DETECTION ANDE" Yvvw�Y, I_ __ LIGHTNING PROTECTION DEVICES. J 4? WALL MOUNT 6. DEDICATED BRANCH CIRCUIT(S) AND CONNECTIONS SHALL BE MECHANICALLY # Ilir ''LII 0 II ISI SHOWER aveRre D(�-1PROTECTED. 158 OCATION `=1' j7. CIRCUIT DISCONNECT MEANS SHALL HAVE A RED MARKING, IDENTIFIED AS - '=•=•=••.•••• M-6 "FIRE ALARM CIRCUIT". �I� SII' 8. AUDIBLE ALARMS SHALL CONFORM TO SECTION 18.4.3 PUBLIC MODE :••:•:•-_ •:•_• ELEC. MECH CIRC. (NEPA 72). 13011 [302J 1112 LL-1 9. CENTRAL STATION MONITORING SHALL BE DOCUMENTED UPON COMPLETION CITY Or TIGtRJnD F M-3 OF THE PROJECT IN ACCORDANCE WITH SECTION 26.6.3 (NFPA 72). _ - 10. A RECORD OF COMPLETION SHALL BE PROVIDED TO THE FIELD INSPECTOR 'S + `D AOR CODE COMPLIANCE WF MRI MECH AT THE ACCEPTANCE TEST INSPECTION IN ACCORDANCE WITH UTILITY M-4 FAC U M-2 - SECTION 14.6.2.4 (NFPA 72). Approved: t I. � pi 5 DOC 11. A LOCKABLE DOCUMENT STORAGE CAN SHALL BE PROVIDED. OTC: r (,�'Ulj�M-5 FACPIII Permit#: ! _1 -„Pii CIRC. J - Address: t %fL,'...� 1 I,5� BREAK i] I=- 3 Z NOTIFICATION CIRCUIT SCHEDULE Suite# ' 1 c Ce c_ - VOLTAGE DROP CALCULATIONS BY: �a �a Date: ,„�, Q o RR OFFICE br-- H NO NOTIFICATION REQUIRED 1541 Z �113j 0 z �'//1� W CKT DEVICE LOCATION / AREA CIRCUIT TOTAL WIRE WIRE VOLT VOLT ACCL'i LU VOLT " (n J z ORIGIN AMPS DIST SIZE DROP AT EOL DROP DROP X L U N O O N-1 SPARE SPARE FACP 0.000 0 14 0.00 20.40 YES 0.002 RECEPTION - 0 CLC N-2 SPARE SPARE FACP 0.000 0 14 0.00 20.40 YES 0.00% J RR j 1P2 LOZ *****END-OF-UNE METHOD OF CALCULATION W t[) OFFICE COPY OFFICE [1o3J a0 CK 0 LLI FIRE ALARM EQUIPMENT SYMBOL LIST ® L Z J SYMBOL DESCRIPTION PART # ROUGH-IN / NOTE MOUNTING HEIGHT CIRC. N z Et FACP FIRE ALARM CONTROL PANEL NOTIFIER SELF-CONTAINED SURFACE MOUNT 54" TO TOP OF HIGHEST O Z NAY-50 19"H X 16.65"W X 5.25"D USER FUNCTION AFF n FIRE ALARM COMMUNICATOR 3G DC 5.4" X 8.8" X 2.2" ALIGN WITH OTHER EQUIPMENT CL BATTERY CALCULATIONS 07 CEI WATER FLOW SWITCH BY OTHERS MONITORED BY NMM-100P NOTIFIER N FW-50 (MECH 30 2) REVERED/APPR 01ED' Q TAMPER SWITCH BY OTHERS MONITORED BY NMM-100P PART # DESCRIPTION QTY STANDBY STANDBY TOTAL ALARM ALARM TOTAL e;1---2 - NFW-50 MAIN CIRCUIT BOARD 1 0.1200 0.1200 0.2000 0.2000 BEN BREIT - 4460LEA ® ADDRESSABLE INPUT MODULE - MINI NOTIFlEI2 SINGLE GANG ALIGN WITH OTHER EQUIPMENT DWG REV / DATE NMM-100P NOT-BG12L.X PULL STATION ADDR 1 0.0003 0.0003 0.0003 0.0003 0 05/25/17 SINGLE GANG, OR GANG NP-100 PHOTOELECT ADDR HEAD 1 0.0003 0.0003 0.0065 0.0065 .. El ADDRESSABLE MANUAL PULL STATION NOT-BG12LX DOUBLE NOTIFIER 4" SQUARE,ANG BACK BOX 46" TO CENTER AFF NMM-100P MINI MONITOR MODULE 4 0.0004 0.0016 0.0050 0.0200 STANDBY TOTAL 0.1222 ALARM TOTAL 0.2268 24 PHOTOELECTRIC SMOKE DETECTOR NOTIFIER 4" OCT OR SINGLE GANG CEIUNG MOUNT *CALCULATIONS BASED ON 24 HR STANDBY TIME & 5 MIN ALARM TIME* DRAM BY: NP-100 AMPS (A) X TIME (H) = AMP-HRS (All) 20X DEBATE TME P. STANDBY 0.1222 X 24 = 2.9328 - CHECKED BY: B 120 VOLT WATER FLOW BELL BY OTHERS BY OTHERS BY OTHERS ALARM 0.2268 X 0.0833 = 0.0189 BJB nTOTAL AH - 2.9517 3.5420 FILE NAME DOCUMFLASH ENT ENCLOSURE WITH INTERNAL SPACE AGE SSU00685 USER FUNCTION AFF 12"W X 13"H X 2-1/4"D 54" TO TOP OF HIGHEST FA.dwg BATTERIES TO BE INSTALLED: 7.0 AH DRAWNG ft *****WP - WEATHERPROOF DEVICE LF - LOW FREQUENCY DEVICE FA-1 C - CEILING MOUNT ORIG. SHEET SIt : 11"x 17' /OF DwGS WA SET SHEET 1 OF 3 888 s .z 1 :: FIRE ALARM OPERATIONAL MATRIX i SYSTEM OUTPUTS ADDRESS SCHEDULE Ig8. ADDRESS DEVICE LOCATION / AREA 10) �p4 e D-1 PHOTO MECH 302 �7S e�p4dt 4rt y0•ct• �p�4 + M-2 MONITOR MECH 302, COMM TROUBLE 11110 ��a M-3 PULL ELEC 301, PULL STATION *IMI iv GO CJS 5r M-4 FLOW ELEC 301, WATER FLOW �oG" ? �, 4 y � ' M-5 TAMPER ELEC 301, TAMPER SWITCH g �O Q�i q49 Q� Q. O M-6 MONITOR ELEC 301, PW M c9 dee N.' -09� 0.yy�,44 4'1)5;2 6 A-7 SPARE SPARE pkFe4cg p. 0 ���66 0'3'4'4 a p,sts ce A-8 SPARE SPARE I M y. S pQv pQc. Qi. y1(. A-9 SPARE SPARE SYSTEM INPUTS p�"p �P cA4, 43'P -Q pG�,P�,P�,? ���� e� A-10 SPARE SPARE 447 NOTES: •** SPARE CONTINUES *** PULL STATION • • • • SMOKE DETECTOR • • • • A-50 I SPARE ISPARE SPRINKLER FLOW SWITCH • • • • • D- DETECTOR W SPRINKLER TAMPER SWITCH • • AM- MODULE- SPARE !— I LOSS OF AC POWER AT FACP • • v, V ^^ OPEN CIRCUIT • • LU !! DISCONNECTION OF BATTERIES • • V GROUND FAULT • • I } ! n LL Y — SLC - \ / SLC - TO NEXT DEVICE 0 Q O FROM FACP SLC INOR SLC OUT OR Z O PREVIOUS DEVICE (TYPICAL 152C) (TYPICAL tow TO FACP FOR SLC + SLC + OPTIONAL CLASS A 0 Z NJ Z FIRE ALARM RISER DIAGRAM _0 1- v�io (TYPICAL) CAUTION: l� LU" U7 a DO NOT LOOP WIRE UNDER jl I Il n TERMINAL 1 OR 2. CL D-01 M-2 M-3 M-4 M-5 M-6 BREAK WIRE RUN TO PROVIDE Cl. SLC • G. © 4M Imo► SUPERVISION OF CONNECTIONS. O 0 O O % 18/2C FPLR FAC © Q 0� _ _ I Y 1 2 3 4 Y • 120VAC 0 � BY OTHERS �p GAUt�� � � � E � 7 EOL_ EOL EOL EOL ; . 3 , , 11 „ 4 0 L 4.71([1° 4.7 e 4.71((1° 4.71(8 ° t�!�t¢x g in LL FACPI Or! 0_ (MECH 302 I , • �l Q SLC 1 SPARE----ZZ EOL_ 1.351([1 O O O O 18/2C FPLR l NOTIFlER ° 3OWE REV. / DATE RJSLC NFW-50 2 SPARE---ZZ—�2 EOL, .351(8 0 05/25/17 FA_ UM W/INTEGRAL El DACT TYPICAL NAC 14/2C FPLR \\ 13.9 DRAWN BY: ' 120VAC DEDICATED PULL STATION TME CFECICw BY: BJB GI PULL STATION FILE NAME SCALE: NTS FA.dwg DRAWING# FA-2 ORIG. SHEET SIZE 1rx 17' #OF OWES IN SET: SHEET 2 OF 3 888 442 5 1 �.198E4 igg La tn v iNip Iosi 16 \ � FROM FACP E OR PREVIOUS DEVICEI it it TO MONITOR MODULE I SLC - NEXT DEII n n SLC INTO FOR (TYPICAL 18/2C) O OFNAL CLASS A . • 0 O C SLC + SLC - SLC - \\'1J FROM FACPOR SLC IN SLC OUT O PREVIOUS DEVICE (TYPICAL 1820) (TYPICAL 1820) W 0 • SLC + • SLC + T7 (-) HMONITOR MODULE !^ T9 T2( (+) N W TB T9 67� I=F-1 678 T7 ,':L L, , T4 TO NEXT DEVICE 2�i�\ ADDRESS a 4I ) w TS '-� • /1 4 T6 '/� ++ am OR :41P :410) . TO FACP FOR � r� 2q M w ' o \OPTIONAL CLASS A 1 21 '� o °Ns SLC - TENS Ell ONES H V Q O O SLC OUT • • loime • • n/ Y z s. (TYPICAL 1820) LiL. d U U \ SLC + (-) (+) (+) (-) 0 < W CA \ YELLOW VIOLET RED BLACK Z O O \ TYPICAL tax \. / r`A' OI Z TYPICAL 1812C //,/ N J PADDLE FLOW SWITCH PAM-2 TYPICAL 18/2C \ / U 3 z OR WHITE BLUE Q N O TAMPER SWITCH / •OV(-) C in o W In GREY YELLOW ^ --• NC NC •— •+24V©0.015 A NC S I n/ • C C • 0 I.L ra �4e / RED •+12V@O.015 A NO • ORANGE � • I /--• NO NO L 1 EOL eK0 H Y LLO Z POWER SOURCE *"*FOR USE WITH FLOW SWITCH*** Ct (BY OTHERS) n \ TYPICAL 1820 1..1� \ e 120VAC 120VAC \, POWER FLOW BELL[ \ ,---, V / e OUT PWR(IN) (BY OTHERS) e e a m o a e m a s m m m m m OGG m o s s m O�O PWR(OUT) _L- _- A A - CA - n N N N N G O + A D D 0 ; 2 2 2 ; N w A A A N ; SAFE OFF N W +• Z Z GM < i \ Kw...4 UNUSED CONDUCTORS .I DWG REV. / DATE PWR(IN) PWR(OUT) TERMINAL BLOCKS O ER SUPPLY 0 05/25/17 O O PGM4 IS OPTIONAL BECAUSE uDIAL TONE IS NOT GENERATED WHEN CELL SIGNAL IS LOST DRAM BY: TME CHECKED BY: O PIV, FLOW OR TAMPER SWITCH MONITOR • COMM TROUBLE MONITOR BEs FILE NAME: SCALE: NTS SCALE: NTS FA.dwg DRAWING it FA-3 ORIG. SHEET SIZE: 11'x 17' I OF DWGS M SET: SHEET 3 OF 3