ElTree location verified per approved site plan.
I:\Building\Forms\StreetTreeCertificate 05/30/2012
Oregon Residential Specialty Code R318.2
MOISTURE CONTENT ACKNOWLEDGEMENT FORM
I, f,tk\ CA YVti
am the general contractor or the owner-builder
at the following address:
Site Address: \ L Li) kr -.
City: '-i J it,.ez1
Permit#: 433
Subdivision/Lot#: NIA (A.1 yk rz_vk L
�T
and/or
Map and Tax Lot#:
To conform with the 2008 Oregon Residential Specialty Code(ORSC), Section R318.2 and
OAR 918-480-0140, I am notifying the building official that I am aware of the moisture content
Requirement of ORSC Section R318.2 and have taken steps to meet this code requirement.
[Section R318.2 is provided for reference].
R318.2 Moisture Content: Prior to the installation of interior finishes, the building
official shall be notified in writing by the general contractor that all moisture-sensitive
wood framing members used in construction have a moisture content of not more than 19
percent by dry weight of dry framing members.
Signature: � /" ��---__..... Date: CI S� /
General Contractor or Owner-:'T der
I:\Building\Form\RES-MoistureSensitiveWood.doc 09/25/08
Oregon Residential Specialty Code N1107.2
HIGH-EFFICIENCY INTERIOR LIGHTING SYSTEMS
•
L{ 7
Permit No.: Jurisdiction:
Site Address:
Subdivision/Lot#: \h. I IAA
4 41, LA,
and/or
Map and Tax Lot#:
By my signature below, I certify that a minimum of fifty(50)percent of the permanently
installed lighting fixtures in the above mentioned building have been installed with compact or
linear fluorescent, or a lighting source that has a minimum efficacy of 40 lumens per input watt.
(Oregon Residential Specialty Code N1107.2)1
Signature: d�'
� Date: (r15 1'"I
07'7/General Contractor/ orized Agent
Print Name: y k () Vi /(J
1 ORSC Section N1107.2.High-efficiency interior lighting systems. A minimum of fifty(50)percent o the
permanently installed lighting fixtures shall be installed with compact or linear fluorescent,or a lighting source that
has a minimum efficacy of 40 lumens per input watt. Screw-in compact fluorescent lamps comply with this
requirement.
The building official shall be notified in writing at the final inspection that a minimum of fifty percent of the
permanently installed lighting fixtures are compact or linear fluorescent,or a minimum efficacy of 40 lumens per
input watt.
I:\Building\Forms\RES-HighEfficiencyLighting.doc 07/01/08
Building Airtightness Test Form
Customer Information: Wes Boisvert—503.488.9602 cell
Name: Riverside Home Address: 17933 NW Evergreen Pkwy—Suite 370
City: Beaverton State/Zip: OR 97006
Phone: 503.645.0986 Email: wboisvert@riversidehome.com
Building Address:(if different from above): Lot#5
Street: 12863 SW 133'Ave City/State/Zip: Hillsboro,OR 97223
Building and Test Conditions:
Date: 05/31/2017 Time: 8:00 Atmospheric Conditions: Calm
Floor Area (ft2): 2,885 Volume(ft3): 24,432 Exterior Surface Area (ft2): 5,524
#Bedrooms:5 #Occupants:6 Wind Shielding: Low
BAS: 2,309 ACH@BAS: 5.7 BAS@70%: 1,616 ACH@70%: 4.0
Test#1 : Fan Model/SN: Minneapolis Blower Door
Depress: X Press Pre-test Baseline Press: -0.1 (Pa) Post-test Baseline Press:-0.2 (Pa)
Bdlg Press:(Pa) -50.0 Flow Ring Installed: A Fan Press:(Pa) 120 Flow:(cfm) 1,967
Results:
CFM50: 1,967 CFM50/ft2: 0.68% Mpls Leakage Ratio: 0.36%
Comments:
Test#2 : Fan Model/SN:
Depress: X Press_ Pre-test Baseline Press: (Pa) Post-test Baseline Press: (Pa)
Bdlg Press:(Pa) -50.0 Flow Ring Installed: Fan Press:(Pa) Flow:(cfm)
Results:
CFM50: ACH50: CFM50/ft2: Mpls Leakage Ratio:
(Pa):Pascal a pressure unit-(CFM):cubic feet per minute-(CFM50):cubic feet per minute at 50 Pascal
(ACH50):Air Changes per Hour at 50 Pascal - (BAS)Building Airflow Standard
(CFM50/ft2):%air leakage per square foot—(Mpls Leakage Ratio)—%air leakage per exterior surface
ASHRAE Standard 62.2,and is only appropriate for low-rise residential structures.
Recommended Whole Building Mechanical Ventilation Rate:This value is the recommended whole
building ventilation rate to be supplied on a continuous basis using a mechanical ventilation system.
The recommended mechanical ventilation rate is based on 7.5 CFM per person(or number of bedrooms
plus one—whichever is greater), plus 1 CFM per 100 square feet of floor area.This guideline assumes
that in addition to the mechanical ventilation,natural infiltration is providing 2 CFM per 100 square
feet of floor area.
ACH at 70%BAS or Below=Air Changes per Hour at 4.0 ACH or Below Installation of Mechanical
Ventilation Strategy is Required—