07/27/1976 - Packet AGENDA
Aftw Tigard Site Development Plan & Architectural Design Review Board
July 27, 1976 - 5 : 00 P.M.
General Telephone Building
12460 SW Main St . , Tigard, Oregon
1 . CALL TO ORDER:
2 . ROLL CALL :
3. APPROVAL OF MINUTES :
4 . COMMUNICATIONS :
5. DESIGN REVIEW
5 . 1 SDR 22-76 (Atlas Land Company)
A request for review of a new 16, 000 square feet industrial
building at 9380 S.W. Tigard St .
A. Site Development Plan
B. Architectural Design
5. 2 SDR 24-76 (Gaffers Pub)
A request for review of a 4250 sq. ft . expansion and remodel
of a restaurant/pub in the Tigard Plaza Shopping Center at
S .W. Pacific Hwy. and S .W. Hall Blvd.
A. Site Development Plan
B. Architectural Design
5 . 3 SDR 25-76 (Byers Photo Equipment Company)
A request for review of a new 20 space parking lot at
6955 SW Sandburg Road.
A. Site Development Plan
B. Architectural. Design
5.4 SDR 26-76 (Payless Shopping Center)
A request by Payless Northwest , Inc . and Albertsons for
review of a proposed department/grocery store at SW Main St .
and SW Scoffins St .
A. Architectural Design
Agenda
Tigard Site Development Plan & Architectural Design Review Board
July 27, 1976
Page 2
5. 5 SDR 28-76 (Fahlman Greenhouse)
A request for review of a 1200 sq. ft . greenhouse at
12555 SW Hall Blvd.
A. Site Development Plan
B. Architectural Design
STAFF RT!:-'PORT
Tigard Site Design Plan
and Architectual Design Review Board
July 13, 1976
General Telephone - 5:00 p.m.
Tigard, Oregon
DOCKET: SDR 22-76
REQUEST: For site and architectual review of a proposed
150001 industrial building.
LOCATION: 9350 SW Tigard Avenue.
APPLICANT: Atlas Land Company
BASIC FACTS:
1. Site is designated as general industrial on the Neighbor-
hood Plan II and zoned 114-4 (Industrial Park) .
2. The surrounding land use consists of an existing industrial
warehouse building on the east, the Oregon Electrical
Railroad tracks on the north, Fanno Creek flood plain on
the south, and a five unit single story apartment building
to the west.
3. Fanno Creek flood plain at this site is approximately 1511 .
4. Sd Tigard Street is designated as an arterial in the
Neighborhood Plan II and the Tigard T�Tunicipal Code requires
a 201 center line setback prior to measuring the required
401 front setback.
5. Sir^T Tigard Avenue is presently 40' right way.
6. Section 15.60.120 Tigard Municipal Code requires one
parking space per 1000 square feet industrial uses.
FUTDINGS:
1. All setbacks have been satisfied.
2. Minimum of 15 parking spaces need to be provided on the
site. 12 are shown on the site plan. The other three can
be added to the front of the building when the loading
areas are further desigated.
3. Applicant proposed a 36' curb cut to be used jointly
by the existing building and the new building which are
on separate tax lots. The code requires that the tax
lots either be combined or a cross agreement be executed.
4. S7".J' Tigard Street is presently in a substandard condition
and needs improvement in the near future.
Staff Report
Design Review Board
July 13, 1976
Page 2
5. SW Tigard Street is presently 401 right way whereas a
601 right way is called for in code. An additional
101 dedication appears to be necessary.
6. Section 18.58.080 Tigard 14unicipal Code requires that all
areas not occupied by paved roadways, structures or walk-
ways be landscaped. The applicant has shown landscaping
in all the mentioned areas except immediately adjacent
to the building on the Tigard Street side.
Section 18.58.080 also requires that a minimum of the
front 20 feet of the lot be landscaped. The site plan
shows Tam Juniper, Azalea, Birch and Shore Pine. The
selection of material appears to be adequate although the
Juniper appears to have too large of spacing.
C�
7. The site plan proposes 41 to 51 tall Shore Pine along the
west side of the new building. This should adequately
screen the industrial building from the existing apart-
ment building.
8. The applicant proposes to locate three landscaped islands
in the parking lot. The two at the front should adequately
cut off the visual impact of the two parallel buildings
with parking in between and should eliminate the "bowling
alley" effect, as will the landscaped island adjacent to
the new building.
9. The site plan proposes to have Sycamores, 8 to 10 feet
tall, in the planting islands with an evergreen ground
cover and flowering shrubs. Visual impact across Fanno
Creek is minimized by the location of the existing oak
C)
and ash trees along Fanno. These will remain.
10. The code requires 611 wheel blocks on parking stalls.
11. No signing program has been submitted.
12. No irrigation system for maintenance of the landscape
is shown.
13. The Tigard Municipal Code requires sidewalks serving all
parcels. No sidewalk is shown on the site plan.
14. Tigard Municipal Code requires all utilities to be under-
ground.
Staff Report
Design Review Board
July 13, 1976
Page 3
Staff recommends approval of the following conditions:
1. Either a cross easement agreement be recorded assuring
joint use of the access drive or the tiro lots be combined
to form one tax lot.
2. An agreement to participate in future improvements to SW
Tigard St. be filed with the city Recorder.
3. A dedication of 101 along S5'i Ti-ard St. be completed for
future widening.
4. Landscaping along the front of the building be continued
up to the building.
5. Tam Juniper be planted 41 on center.
6. The landscape islands be curbed.
7. 611 wheel blocks be provided for all parking stalls.
8. The signing program consist of a 321 directory sign with
wall mounted identification signs not to exceed 121 .
"N" 9. Irrigation plan be submitted to Staff for approval.
10. A 51 sidewalk be placed adjacent to the property line.
11. All utilities serving the site be placed underground.
w*
STAFF REPORT
Agenda 5 .2
Tigard Site Development Plan and Architectural Design Review Board
July 27, 1976 - 5: 00 P.M.
General Telephone
12460 SW Main Street - Tigard, Oregon
DOCKET: SDR 24-76
REQUEST: Site plan and architectural design review of a proposed
remodel and expansion of Gaffer ' s Fish and Chips .
LOCATION: 206 Tigard Plaza
APPLICANT: Gaffers, Inc .
BASIC FACTS :
1 . The site is designated Retail Commercial on the Neighborhood
Plan II and zoned C-3 General Commercial .
FINDINGS :
1 . The existing site is in the southwest corner of the Tigard
Plaza.
2 . The request is for expansion of the Gaffers Restaurant into
another portion of the existing building with landscaping
and signing of the existing site.
3. The area shown to be landscaped on the site plan is presently
covered with asphalt paving thus there is a need for adequate
site preparation and the 12" top soil recommended in the
site plan will not be adequate for root growth.
4 . The site proposes the addition of primarily pines with three
rhododendron shrubs . The addition of more colorful shrubs
would greatly enhance the site.
5 . Site plan shows the extension of the existing sidewalk. Any
extension of the sidewalk should also make provision for a
wheelchair ramp .
6 . The Mugho pine are shown to be 2 ' tall . They should be a
minimum of five gal .
7 . The existing 30 ' x 30" sign on the east side of the, Oti*tlding
is shown to be replaced with a 24 ' x 36" sign to be mounted
on the new front of the building. The sign is shown to
project out from the building approximately one foot . This
should be flush with the building or a part of the overhang.
In order to conform to the signing program for the remainder
of the Tigard Plaza and that projecting signs are not
allowable in this zone.
Staff Report
Agenda 5 . 2
July 27, 1976
Page 2
8 . No irrigation system is shown for the landscaping areas and
no hose bibbs exist on the exterior of the building at
this site .
STAFF RECOMMENDATIONS :
Staff recommends approval with the following conditions :
1 . The extension of the existing sidewalk terminate in a
wheelchair ramp .
2 . The landscaped areas be supplemented by the addition of
colorful shrubbery such as creeping broom, azeleas , poten-
tilla.
3. Mugho Pine be a minimum of five gallon.
4 . The existing sign be placed flush with the building or
part of the overhang.
5. Irrigation system be subject to staff approval .
6 . That improved top soil surround the root balls and a hole
dug for the roots to be 12 to 2 times the size of the root
ARW system.
7 . That the landscape plan be revised according to the altera-
tions marked in red by staff on the submitted landscape
plan .
-arrw
STAFF REPORT - Agenda 5. 2
Tigard Site Development Plan and Architectural Design Review Board
July 27, 1976 - 5: 00 P.M.
General Telephone
12460 SW Main Street - Tigard, Oregon
DOCUMENT: SDR 26-76
REQUEST: Architectural Review only of proposed Albertsons/Payless
Store in the proposed Payless Plaza.
LOCATION: SW Main and SW Scoffins
APPLICANT: Payless Drug Stores
BASIC FACTS :
1 . The site is designated retail commercial on the Neighborhood
Plan I and zoned C-3M Plan Development .
2 . The planned development allowing this shopping center was
approved by the City Council on November 10, 1975, with the
following conditions :
1 . Payless provide storm sewer :subject to Public Works
approval .
,*AW 2 . That no left turns be permitted from or onto Pacific
Highway between Main St . and Hall Blvd. and that a no
left turn island be provided by the applicant on
Pacific Hwy.
3. The land be dedicated for public street right of way as
shown for SW Scoffins St . widening and the main street
realignment .
4 . That Scoffins St . be developed to a 36 ' roadway and a
60 ' right of way to the south property line.
5. That each street improvement recommendation contained in
exhibit C above be executed and placed by the applicant .
6 . That all streets, public facility improvements be made
to meet City standards including but not limited to
curbs, sidewalks and storm drainage .
FINDINGS :
1 . The applicant is requesting architectural review of a pro-
posed 70, 000 sq. ft . building to be occupied by a Payless
Drug Store, an Albertsons grocery store and four lease spaces .
2 . The face of the building is shown to be primarily concrete
block with a cedar shake overhang.
Staff Report
July 27, 1976
Page 2
3. The Albertsons and Payless areas of the building are to be
off-set 20 ' as per a recommendation by the Design Review
Board during the preliminary review. The overhang is not
shown on site plan to be continued around this corner.
During wet weather this 20 ' gap in the canopy would be
undesirable. This horizonal feature should be continued
the entire length of the building and wrapped around the
corners much the same as done on the west portion of the
building.
4 . No east or south elevation of the Payless building are
shown and no east elevation of the lease space adjacent
Albertsons .
5 . The site is below grade of the Pacific Hwy. overpass thus
the traveling public has a direct view onto the flat roof
of the proposed building. Normally this area is dotted
with air-conditioning units and other mechanical features.
The submitted architectural plan does not specify mechanical
location nor does it show screening which may be necessary.
They should be either located in the rear of the building,
or if on the roof they should be effectively screened.
6. No signing program has been submitted by the applicant .
The only information provided on the signing are on the
elevations provided. These two signs show a 32 ' by 5 '
Albertson sign and a 52 ' by 5 ' Payless sign, both on a
white stucco background.
7. The front face of the building (York Block and Split-Face
Concrete Block) should be continued the entire face of
the building much the same manner as the cedar shake over-
hang and the spacing of the wood beam columns have .
8 . There is evidence of illegal subdivision on the site. This
is not a major factor in the Architectural review but should
be remedied prior to any submission for site plan review.
9 . In that there is a 7, 000 sq. ft . lease building to the
rear of the building the architectural amenities depicted
for the front portion of the building should also be pro-
vided for the rear . For example the chainlink fence shown
for the rear of the Albertsons should become an extension
of the building ( ie broken face block) . The parking lot
to the rear leads staff to the conclusion that entry from
either side should be provided for at least one of the
two stores . Payless is most favorably situated for this
purpose.
STAFF RECOMMENDATIONS :
Staff recommends approval of the front ans southwest elevation
and denial of the rear elevations with the following conditions :
Staff Report
July 27, 1976
Page 3
1 . The concrete block and York block face of the building
be continued the entire length of it .
2 . The cedar shake overhang be continued around the corner
between Payless and Albertson ' s much the same as on the
west elevation of the building.
3. A signing program for the entire site be submitted to
Design Review prior to the issuance of any sign permit .
4 . The location of exterior mechanical units be approved by
the Design Review Board with particular concern for the
screening of roof mounted units .
5. Violations of the subdivision ordinance be rectified prior
to site plan review.
6 . The elevation found lacking in staff finding number 4
be submitted for approval .
STAFF REPORT
Agenda 5 . 3
Tigard Site Development Plan and Architectural Design Review Board
July 27, 1976 - 5 :00 P.M.
General Telephone
12460 SW Main Street - Tigard, Oregon
DOCUMENT: SDR 24-76
REQUEST: Site plan review of a proposed 20 space parking lot
LOCATION: Byer ' s Photo Equipment - 6955 SW Sandberg Rd.
APPLICATION: Don Byer - Byer ' s Photo Equipment
BASIC FACTS :
1 . The site is designated General Industrial on the Tigard
Community Plan and zoned M-4, Light Industrial .
2 . The site is presently in turf with unkept landscaping along
the north portion of the site . There are two large old
cherry trees and two large Douglas Fir in the area of the
parking lot . These are shown to remain .
Surrounding land use in this immediate area is Torro Manufacturing
on the west and Hyster Manufacturing to the immediate north.
FINDINGS :
1 . The parking spaces shown on the site plan are 9 ' wide .
Section 18 . 60. 160 requires parking stalls be 916" wide. This
can be accomplished by moving the parking area either east
or west .
2 . The site plan shows that the parking area will have "new
asphalt paving" , but no cross section of paving is shown .
Section 18 .60. 170 of the Tigard Municipal Code requires
parking lots to be improved to local street standards .
3 . The two planting islands in the parking lot are shown to be
three feet wide . This is a rather small area and should be
expanded to 51 ; especially with the type of Pin Oak that
are shown for the landscaping strips . Pin Oak has a span
of 40 ' and a trunk width at maturity of three to four feet .
4 . No groundeover is shown in the planter strips. The addition
of ivy would be adequate .
5 . The driveway is shown to enter at the street at 281 .
Section 18 . 34 . 030 of the Tigard Municipal Code requires that
curb cut to be 301 . Upon inspection it was discovered that
the distance between the two Douglas Fir trees is less than
25 ' . A driveway constructed at that point and not disturb-
ing the Douglas Fir is desirable . This can be achieved by
Staff Report
Agenda 5. 3
Design Review Board
July 27, 1976
Page 2
a variance to the Tigard Municipal Code issued by the
Planning Commission .
6. Adequate back space for the eastern portion of the site
is provided.
7. The site plan proposes to use the original landscaping plan
at the time of construction of the building, June 22 , 1973 .
Site plan shows Photinia Fraseria which are presently on
the site . Any which are in that area of the proposed
parking should be moved back and retained . Also the addi-
tion of the same type of Baltic ivy as existing on the
Hyster site planting strip adjacent to this planting area
be also continued.
8. There are presently three coast pine to immediately east of
the parking lot one of which is dead. This should be replaced
by a similiar size tree.
9 . There is an approximately 10 ' change of elevation from the
Douglas Fir trees down to the existing parking area. This
presently is in barkdust and a few low evergreens . Evidence
of erosion is apparent . The driving of cars in the general
area will tend to increase that erosion . The addition of
landscaping such as ivy or juniper would help stabilize
that bank.
10. There is one hose bibb on the north side of the building.
This will be no closer than 60 ' from the landscaping.
STAFF RECOMMENDATIONS :
Staff recommends approval with the following conditions :
1 . The planting strip be widened to 51 .
2 . All parking spaces be 9 '6" in width .
3 . The original landscape plan be adhered to with the addition
of ivy along the area between Hyster and the parking lot
and replacement of dead coast pine along the east perimeter
of the parking lot .
4 . Asphalt paving be to standard for local streets .
5 . Irrigation plan be submitted to staff for approval .
6. Groundcover be added to the sloped area from around the
north edge of the existing parking lot .
7 . A variance be acquired reducing the width of the curb/cut
from SW Sandberg in order to save the two existing Douglas
Fir trees.
STAFF REPORT
Agenda 5. 5
Tigard Site Development Plan and Architectural Design Review Board
July 27, 1976 - 5 : 00 P.M.
General Telephone
12460 SW Main Street - Tigard, Oregon
DOCKET: SDR 28-76
REQUEST: Site plan and architectural review of a 1200 sq. ft . greenhouse
LOCATION: 12555 SW Hall Blvd
APPLICANT: Michael D. Fahlman
BASIC FACTS:
1 . The site is designated Urban-Medium Density Residential Neighbor-
hood Plan I and zoned A-2 Multi-Family Residential .
2. A conditional use permit for the greenhouse was approved by
the Planning Commission November 25, 1975, and approved with
the following conditions :
1 . Approval subject to Design Board review as such time as
expansion is undertaken . Providing a commercial access
is to be from SW Scoffins St . The site has one residential
dwelling and an existing greenhouse . Surrounding land
use is apartments behind and to the south .
3 . The setback requirements in a A-2 zone are; front yard set-
back of 20 ' and sideyard setback of 5 ' . The Tigard Municipal
Code further requires in Section 18 . 12 . 100 that a 40 ' additional
setback along SW Hall Blvd be required thus not allowing any
permanent structures 60 ' from the center line. Site plan
shows the front yard distance to be less than that .
4 . The exterior of the greenhouses is proposed to be plastic .
This should be effectively screened from both the apartments
to the south and the traveling public on SW Hall Blvd. The
plantings of either arbor vitae or other 5 to 8 ' evergreen
plant material would be adequate .
5 . The Tigard Municipal Code requires all business activity to
be carried on within structures . The site presently has out-
side display areas . These are in violation of the code and
should be remedied.
6. The exterior finish of the greenhouse is proposed to be
visqueen. This is a thick plastic and is very temporary
with a very limited life and tends to age and deteriorate
rapidly. This appears to be an inadequate exterior finish
and should be a fiberglass or glass exterior which would be
more attractive and lasting on the site.
Staff Report
Agenda 5 . 5
July 27, 1976
Page 2
STAFF RECOMMENDATIONS :
Due to the inadequate setback from SW Hall and the inferior
exterior material staff recommends DENIAL.
`wrr
M}'MORANDU
TO: Design Review Board
FROM : Planning Staff
RE : City Attorney Opinion on Design Review Board authority
over signs .
At the June 22nd meeting, the question as to the role and
authority of the Design Review Board in reviewing signs arose.
Upon your directive, an opinion from the City Attorney was
sought . His verbal reply to the Planning Director was as
follows :
1 ) Si ;-ns attached to a building are part of that structure
and are thus revin able as a part of tate building
architecture .
2) Free standing signs are structures within the standard
definition used in the Tigard Municipal Code , Uniform
� Building Code and numerous courtc-ases on the subject .
Therefore signs, either free stranding or attachVd , are
reviewable and within the jurisdiction of the Desig&, Review
Board to regulate. Signing programs will now be unifbrmily
required as past of the submission .
burr
'OEMORA\D1314
To : Design Review I3oard
From: Planning Commission Staff
Pe : 1 Street Improvement for SW Church of Christ
In reviewing the detail plans for construction and
street improvements for the Southyest Church of Christ at
Sod Durham Road and SW 98th Avenue (SDR, 1.8--76 approved
5,/25/76) the Engineering Department has reqs.ested that
condi_tion nu;�ber 5 "A half street i r_provement be made
from the access .point, on SW 98th Avenue around to the
Durhnm Road right-of-way line; street improvements on
SW 98th Avenue to be provided during the later phases of
the church development" be modified . This re c onmendation
is basad primarily on the reasoning that normally the
improvement of such a short segment of a. collector is not
cost efficient .
Three alternative options readily present themselves :
1 . Require an agreement to participate in an L. I .D.
on SI'v 38th Avenue :for future street improvement. .
2 . Inprove the entire length of Sid 98th Avenue
along the subject property at this time .
3. Improve the entire length of SW 98th Avenue
along the subject property as the parcel further
develops and a no -re-iionsl _ ance agreement
at this t.i in
.The Planning staff recommends the third option .