Loading...
Plans (12) PLM2017 - 00042 ( I DESIGNATED BY NDITION OF 70 S 54/ Aecrjy' Z ® THIS SYMBOL PLUMBING FIXTURE SCHEDULE PLUMBING SYSTEMS MSR TO I N BUILDING.CON CONELD VERIFY EISTING TRACTOR TO CUT, CAP, 3 10117 DIRECT INDIRECT ADJUST, AND REROUTE PLUMBING SYSTEMS AS NECESSARY TO r/iWdf/c S FIXTURE NO. SUPPLIED BY TYPE MANUFACTURER: MODEL WASTE WASTE VENT CW HW REMARKS ACCOMMODATE TENANT IMPROVEMENT WORK AND (/(•� P-1 PC WATER CLOSET KOHLER:HIGHLINE K-3979/3979-RA 3" - Z' 1/7' - ADA, 1.6 GPF,WITH K-4650-A OPEN FRONT SEAT&ANGLE STOP MAINTAIN FULLY FUNCTIONING PLUMBING SYSTEM IN P-3 PC LAVATORY KOHLER:PINOIR K-2035-4 7' - 1-1/2" 1/7' 1/7' ADA,PROVIDE K-15182-P FAUCET W/METAL DRAIN&BRASS P-TRAP;0.5 GPM ADJACENT TENANT SPACES. Ken McCracken, P-4 FSE HAND SINK ADVANCE TABCO:7-PS-62 2" - 1-1/2" 1/2" 1/7' - Architect SWANSTONE:MS-2424 BASIN CHICAGO:8 7' 1-1/2" 3/4" 3/4" INTEGRAL VACUUM BREAKER-VERIFY ACCESSORIES W/OWNER Architecture•Program Management•Permitting P-5 PC MOP SINK FAUCET: - P-6 PC FLOOR DRAIN ZURN: T:89210-NT(ADJUSTABLE) 3" 1-1/7' 5"s NPE W NICKEL BRONZE TOP W/TRAP PRIMER CONNECTION AND/OR Z238 16219 SUITE SE I h STREET FUNNEL AS INDICATED VANCOUVER, WA 98683 P-7 PC FLOOR SINK ZURN:FD-2370-DS-H 3" - 1-1/2' - - 17k12"x8"DEEP,SINGLE PIECE W/ 1/2 GRATE AND DOME STRAINER 75 GPM,616 LB.CAPACITY,RECESSED W/INTEGRAL FLOW CONTROL. LIQUID Contact: Martin D. Lakey P-8 PC GREASE TRAP Schier.GB-75 grease intercpetor 4" - T - - CAPACITY: 125 GALLONS,IAPMO LISTED A 112.14.3 P-155'-5" F.0.8. ken.mCCraCken@ComcaSf.net(360)719-1952 '-4" P-9 PC FLOOR CLEANOUT ZURN:ZN-1400(ADUSTABLE) 3' - - - - NICKEL BRONZE TOP 9 10 �\`� P-10 FSE 3-COMPARTMENT SINK ADVANCE TABCO:T9-83-60-18RL 2" - 1-1/2" 3/4" 3/4" VERIFY WITH EQUIPMENT INSTALLER 1 ` P-11 FSE PREP SINK ADVANCE TABCO:TKMG-305 - 2" - 3/4" 3/4" VERIFY WITH EQUIPMENT INSTALLER F.0.6. P-12 FSE WASHER KENMORE:61532/71532 T - 1-I/2" 1/2" 1/2- WALL BOX BY PLUMBING CONTRACTOR GUY-GRAY:WB200-HATM W/INTEGRAL WATER HAMMER ARRESTOR V�[ O P-13 PC WALL CLEANOUT ZURN:Z-1441 2' - - - - W/STAINLESS STEEL WALL COVER - CW CW W CW 2"%W CW CW CW - cW - CW CW W - C11�- TER: LOC. ESTIMATED \ cw - Cw w - �- cw 3"W P-15 PC WATER HEATER RINNAI RI-755(GAS) - - - 1-1/4" 1-1/4" GAS,TANKLESS 180 GPH RECOVERY @ 100°F RISE \ \ ly' V/ Go Q�, o SS SS SS �- 2"V P-17 11 12 S� �ED AR/1�� P-17 PC FLOOR DRAIN ZURN:FD-2210-NT(ADJUSTABLE) 3" 1_1/7' S'0 TYPE'S'NICKEL BRONZE TOP W/TRAP PRIMER CONNECTION AND/OR 2238 NOT A PART a. x f v // co (. FUNNEL AS INDICATED i cW CW cW 2 lYs'V -1 / Z'W SS SS Ir- Ss 3"W CO KENNETH J. P-18 N/A DISHWASHER AUTO-CHLOR:AS WATER SAVER - 7' 1-1/2" - 1/7' VERIFY WITH EQUIPMENT INSTALLER �/ � / ly"V SEWER: LOC. ESTIMATED M RACK NOTES: SS SS - SS - SS = SS SS f SS S SS - SS -5- SS � S - SS - SS 1.ALL FIXTURES MAY BE SUBSTITUTED WITH APPROVED EQUAL. CONTACT OWNER FOR APPROVAL. AMS, WA _ uR 5599 PC=PLUMBING CONTRACTOR. FSE=FOOD SERVICE EQUIPMENT SUPPLIER. > 7 x SS cense 2„W < �A PIPING MATERIALS KEYNOTE NOTES 3 P 12 OF y "w y " "w V�, V 'yam / 3 17 01/31/17 � N f NEW WATER SHUT-OFF VALVE. CONNECT TO 1"MIN. (OR PER CODE) WATER LINE- 3"VTR K�Mn448 1. SANITARY SEWER AND VENT PIPING: 5 7/ " T-6 3 1 1/4" WarerHaater 1 PLUMBING CONTRACTOR TO VERIFY SIZE AND SCOPE FOR REPLACING WATER LINE IF a. SERVICE WEIGHT, CAST IRON BELL AND SPIGOT PIPE AND FITTINGS. NECESSARY. NO-HUB SERVICE WEIGHT PIPE AND FITTINGS MAY BE USED ABOVE GRADE ^ WHEN PERMITTED BY LOCAL CODE. CONNECT TO 4"MIN. (OR PER CODE) SANITARY LINE-PLUMBING CONTRACTOR TO > Sea O VERIFY SIZE AND SCOPE FOR REPLACING SANITARY LINE IF NECESSARY. N 12 b. SCHEDULE 40, GALVANIZED STEEL PIPE AND BANDED MALLEABLE IRON SCREW FITTINGS. TANKLESS WATER HEATER PER O CONNECT TO THE EXISTING 3"VENT THROUGH ROOF IF POSSIBLE-MAINTAIN MIN. 10' 6 4 W P 6 ly"V c. SCHEDULE 40 AND 80 PVC OR ASB PIPING WITH DWV PATTERN FITTINGS FROM ANY AIR INTAKES. PLUMBING FIXTURE SCHEDULE Sn n MAY BE USED WHERE ALLOWED BY LOCAL CODE. FOAM CORE PVC PLUMBING CONTRACTOR TO RUN 3/4"DRAIN LINE FROM WALK-IN COOLER,THROUGH l2 x f I W PIPING WILL NOT BE APPROVED. _ 4 WALL, AND INTO FLOOR DRAIN W/AIR GAP. DRAIN LINE SHALL HAVE TWO (2) INCH P-18 E 2. WATER PIPING-TYPE: - MINIMUM VERTICAL FALL PER 12 INCHES OF HORIZONTAL RUN. P-7 a. "L"HARD COPPER WITH WROUGHT COPPER FITTINGS AND VALVED AT xiJ L� O 3 W GREASE TRAP. LOCATION SHOWN IS FOR REFERENCE ONLY. DRAIN LINES FROM SINK H - HW > HW -� o ® I FIXTURES. 11 SHALL BE INSTALLED TIGHT TO BOTTOM OF BOWL. VERIFY EXACT ROUTING IN FIELD. V V x I f -----____ b. PLUMBING CONTRACTOR MAY USE PEX PIPING FOR ALL INTERIOR b b --- DOMESTIC WATER PIPING IF APPROVED BY LOCAL AUTHORITY HAVING 6 CUT END OF INDIRECT WASTE PIPE ABOVE FLOOR SINK AT 450 ANGLE. ly"V V �>< JURISDICTION-VERIFY IN FIELD. O V S-- ss > S�__���I Ss 6* / 4 3. PIPING INSULATION REQUIREMENTS: 7 VENT DRYER PER LOCAL CODE AND MANUFACTURER'S SPECIFICATION. VERIFY 2^V 4„W-1 IE- y E I a. PROVIDE MINIMUM 1.5"INSULATION WITH MAXIMUM K-FACTOR VALUE OF O LANDLORD APPROVAL OF VENTING METHOD PRIOR TO INSTALLATION. 4"W I Z 0.27 BTU PER INCH/H 'SQ.FT.' DEGREE F, OR AS REQUIRED PER CURRENT Ge8$Up°" II I - II I ENERGY CODE. W4-HmiNiewS„ePlrune 8 PROVIDE HOT WATER MIXING VALVE, WATTS MODEL MMV-Ml OR APPROVED EQUAL- m > I 14bdE Webr auP H Llne id re.awwine r e° SET OUTLET TEMP AT 110°F. r GW -PWI f / Z PLUMBING LEGEND KEY O CONNECT GAS PIPE TO (E) GAS PIPE. CONTRACTOR TO FIELD VERIFY SIZE AND SCOPE P 8 I I 3E k � /> � ¢ K 1&r- Pr.aeereRepWsor FOR REPLACING GAS PIPE IF NECESSARY. I > &4'een V.I. �j 2"\/ 5 > I an 114'Union C4wletin,Pump CW cW Cy/ �`yf CW ' r F- m v7 W pv cn'Union ea a�nv�e 10 TANKLESS GAS WATER HEATER:RINNAI RL75i (OR APPROVED EQUAL) N F � Q POINT OF CONNECTION Pee°eare ReW Vanee Hge„ep VINs 3 P-9 r=ri===ii w w � 11 PROVIDE JOSAM MODEL 88300 TRAP PRIMER AND EXTEND 1/2"PIPING TO FLOOR DRAIN. I. i. .I > Q a COORDINATE ACCESS PANEL WITH G.C. N P-10 > _ -L__u=Jj a O Z OX PLUMBING KEYNOTE (r=ri=_ z t] ? m 12 INSTALL FIXTURE FLUSH WITH FINISHED FLOOR-SEE FINISH SCHEDULE ON SHEET A2.1 a clY cw cW - cW \ / II ;; ;i i; w w o WATER HEATER DETAIL 14 ow ow L_LL_JJ U = m CL io g r= --___� cW_ COLD WATER LINE N.T.S. lye"V a FtW HW a iI rt II o 21W V V - I 6 P-11 -------J w HW HOT WATER LINE CW gyfCw- ply J --- u n n i;r-'i =i�-',,� ¢ C-4N a0 c� GENERAL NOTES HW - HW HWS- HW_ P-13 , , ;; 0 N 0 P-4 8 11 o 0 SS SANITARY SEWER LINE 1. PLUMBING CONTRACTOR MAY USE PEX PIPING FOR ALL INTERIOR DOMESTICTHREE COMPARTMENT SINK ly"VENT W Y < GREASE TRAP WATER PIPING IF APPROVED BY LOCAL AUTHORITY HAVING JURISDICTION- P-13 / V GW VERIFY IN FIELD. IN WALL n A AV3TW lyz'V SANITARY SEWER LINE i \ / i 71W V VENT LINE 2. PRIOR TO BID,THE CONTRACTOR SHALL REVIEW THE MECHANICAL, ELECTRICAL V 8 1/2- 12 P-7 P 13 AND KITCHEN EQUIPMENT DRAWINGS. THE CONTRACTOR SHALL INCLUDE IN HIS CLEAN TS / P-4 8 BID ALL RELEVANT WORK IN THE ENTIRE SET OF DOCUMENTS AND REPORT ALL IN ENDS I 2 2 I 14'-0 3/4" 5'-8 1/2" 9'-2 3/4" CONDENSATE LINE DISCREPANCIES BETWEEN THESE DRAWINGS TO THE ENGINEER PRIOR TO OF PIPE CLEANOU O.B. BIDDING FOR CLARIFICATION. IF DISCREPANCIES REMAIN UNRESOLVED DUE TO A SHORT TIME FRAME,THE CONTRACTOR SHALL INCLUDE THE MOST WORK AND 3 V 2„ GAS GAS LINE THE HIGHER COSTS IN THE BID. SOLUTIONS TO UNREPORTED DISCREPANCIES FLOOR WILL BE DETERMINED BY THE ARCHITECT/ENGINEER,WITH NO ADDITIONAL o COMPENSATION DUE TO THE CONTRACTOR. 3"P-TRAP DW 11Q0 IV IF WALL CLEANOUT CUT AND PATCH � FLOOR IF EXISTING 4„ FLOOR CLEANOUT LOCATE GREASE TRAP IN FLOOR 4 C/) (") WHERE TOP CAN BE EASILY REMOVED FOR CLEANING 1: it FIXTURE AND WATER CALCULATION ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT FIELD CONDITIONS ORii N NAME:PAPA MURPHY'S HOT AND COLD WATER WASTE MEET LOCAL CODE REQUIREMENTS. UTILIZE HUBLESS CAST IRON PIPE, FITTINGS /' It Q a 0 .9 IY AND CONNECTORS FOR SINK CONNECTIONS. CONNECT GREASE TRAP FROM 8 :-~ O MID POINT OF SINK: PROVIDE P-TRAP IF GREASE TRAP IS MORE THAN 4' FROMLIU ° U `i t+� w s TOTAL FIXTURE UNITS Z � " w w � � H SINK. � ty 4L lL Q 6' Z LL LC M � MARK DESCRIPTION CW HW O P-1 WATER CLOSET(TANK) 1 2.5 2.5 - 2.5 3' 1 4.0 4.0 >< 3-COMP SINK DETAIL N.T.S. 1 1 , i 0 P-3 LAVATORY 1 1.0 0.75 0.75 1.0 1-1/2' 1 1.0 1.0 P-4 HAND SINK(b) 2 2.0 3.00 3.00 4.0 1-1/2" 2 2.0 4.0 0 P-5 MOP SINK(b) 1 3.0 Z25 2.25 3.0 7' 1 3.0 3.0 P-6 FLOOR DRAIN(b) 1 _ - 3' 1 2.0 2.0 GREASE TRAP SIZING P-7 FLOOR SINK(b) 2 - - 3" 2 3.0 6.0 GPM&FLOW RATE CALCULATION F P-8 GREASE TRAP 1 - - 31 1 - - FIXTURE TYPE NUMBER OF COMPARTMENTS LxWxH GPM FLOW RATE(b) P-10 3-COMPARTMENT SINK(b) 1 3.0 3.0 3.0 3.0 T 1 4.0 4.0 (1-MIN DRAIN) IN) CAPACITY(Ibs) � P-11 PREP SINK(a) 1 3.0 3.0 3.0 3.0 Z' 1 2.0 0 (a) 3-COMP SINK 3 28x20xl2 38 193 P-12 WASHING MACHINE 1 4.0 3.0 1 3.0 4.0 Z' 1 3.0 3.0 MOP SINK 1 24x24x10 5 -�/ Project Number P-17 FLOOR DRAIN 1 - - 3' 1 2.0 2.0 FLOOR SINK 2 12xl2x8 2 FLOOR DRAIN 1 3"dia. 1 PPM 16049. l P-18 DISHWASHER (a) 1 1.5 - 2.0 1.5 Z' 1 2.0 0 (a) HAND SINK 2 l0x14x5 1 TOTALS 14 - 17.50 17.00 22.00 14 - 29.0 TOTAL 47 193 Sheet Name GREASE TRAP WITH 75 GPM CAPACITY PROVIDED TOTAL WATER FIXTURES 22.00 NOTES: PLUMBING TOTAL DEMAND GPM ANY QUESTIONS OR REQUESTS FOR SUBSTITUTIONS SHOULD BE (GPM .7.50 Note: (a) Formula:{LxWxH}/231 x 0.75=GPM SUBMITTED THRU THE GENERAL CONTRACTOR. THE GENERAL PRESSURE AVAILABLE: 50 PSI (a): Routed to floor sink. If Draining Multiple Sinks Into One Grease Trap: CONTRACTOR SHOULD THEN ISSUE AN OFFICIAL REQUEST FOR PLAN & LOSS AT METER 5.0 PSI (b):Routed to grease trap. INFORMATION TO THE ARCHITECT. 1. Determine the flow rate for each sink to be serviced(a) by the grease trap using the some SCHEDULES LOSS AT BACKFLOW PREVENTER: 10.0 PSI calculations as a single sink. LOSS DUE TO BLDG.HEIGHT: HEIGHT: 10 FEET x 0.433=4.3 PSI 4.3 PSI PRESSURE REQUIRED AT FIXTURE: 15.0 PSI 2. Add together 100%of the largest flow rate,50%of the second largest,and 25%of all others. NORTH Sheet Number PRESSURE AVAILABLE FOR FRICTION LOSS: 5.7 PSI 3. The result is the recommended flow rate (in GPM) of the grease trap.FRICTION LOSS FACTOR 3.5PSI/100FT (b) GPM @ 100%x 2=Flow Rate Capacity(Ibs) LENGTH OF PIPE RUN (FT) 100 FT Code Based on 2014 Oregon Specialty PlumbingPLUMBING PLAN 1/4"=1'-D" 4 [Pil