Loading...
Plans (2) BUP2016 00222 Architecture Interiors Planning Engineering TENANT IMPROVEMENT RECE1q]) : JUL 12 2016 Portland,OR TRIANGLE ICITY 503.224.9560 � �(j� '����� Vancouver,WA �UjL )1JJTD1'VIS101V 360.695.7879 13221 SW. 68TH PARKWAY Seattle,WA 206.749.9993 www.mcknze.com TIGARD, OREGON MACKENZI E. DESIGN DRIVEN I CLIENT FOCUSED .INDEX CSF DRAWINGS DEFERRED SUBMITTAL (DESIGN BUILD) LEGEND client T1.0 CODE SUMMARY PLAN AND NOTES 2014 OSSC SECTION 107.3.4.2 (by separate permit) FIRE SPRINKLER A2.1 PARTIAL FOURTH FLOOR PLAN, REFLECTED CEILING PLAN, KEY PLAN AND NOTES _ FIRE ALARM. EXIT REQUIRED EXIT A8.1 DETAILS AND SCHEDULES MECHANICAL ELECTRICAL CS RICHARD EL.L,IS PLUMBING NOT IN SCOPE OF WORK EXIT ILLUMINATION SCOPE OF WORK NOTE. DESIGN BUILDERS FOR M.E.P. AND FP. ARE FULLY RESPONSIBLE FOR THE DESIGN THE SCOPE OF WORK FOR THE PROJECT INCLUDES INTERIOR TENANT IMPROVEMENTS OF THESE SYSTEMS/COMPONENTS. THESE SYSTEMS/COMPONENTS SHOWN ON DOCUMENTS EXIT SIGN LOCATION Project FOR AN APPROXIMATELY 4,202 SQUARE FOOT TENANT ON THE FOURTH OF FIVE FLOORS. ARE SCHEMATIC ONLY: THEY ARE NOT INTENDED TO REPRESENT FINAL/CODE COMPLIANT SUITE 440/4JO WORK TO INCLUDE NEW WALLS, DOORS, AND CASEWORK. DESIGN. PROVIDE DESIGN DOCUMENT SUBMITTAL TO ARCHITECT OF RECORD FOR REVIEW FIRE EXTINGUISHER LOCATION TENANT IMPROVEMENT _ PRIOR TO SUBMITTAL TENANT APPROVAL: TRIAWX E m 1322'1 SE WTFI PARKWAY DESIGN/CODE DATA TICAM, OR 97223 GOVERNING CODE. 2010 OSSC OCCUPANCY. B _V CONSTRUCTION TYPE: TYPE I-B TENANT AREA (APPROX): APPROX. 4,202 S.F. '�' ¢1ALTO OCCUPANCY LOAD: 43 y 1 REQUIRED EXIT, 2 EXITS PROVIDED RT D, OREGON i ALL EXITS ARE EXISTING AND HAVE APPROPRIATE EXIT SIGNAGE BUILDING IS FULLY SPRINKLED AND HAS NFPA SMOKE DETECTION THROUGHOUT . WITH,ON SITE EMERGENCY GENERATOR FOR FIRE, LIFE/SAFETY BACKUP POWER OF O COMMON PATH OF © MACKHTSJE 2016 SER ALL RIGHTS RESERVED EGRESS TRAVEL: 44'--4" THESE DRAWINGS ARE THE PROPERTY OF MACKENZIE AND ARE NOT TO BE USED OR REPRODUCED IN ANY MANNER, OF DIAGONAL = 31'--1" WITHOUT PRIOR WRITTEN PERMISSION _ _ I Cl'TX OF VGART� REVISIONS: �D FOR CODE COMPLYMN03 Z s w. rl�vtNc Approved: : t,�''' �� REVISIONS REVISION DELTA UTC: �'t +���' LuQ SHEET THIS CLOSING DATE 4�T Address: � Suite#: By: '� Bate: ,�0 97 40 & dt- -f�- y •' •• w.: OFFICE COPY' ,� .�� TRIANGLE SHEET TITLE: CORPORATE PARK - CODE SUMMARY BUILDING III PLAN AND NOTES DRAWN BY: SYB _ CHECKED BY: DMR, PPA NOS SHEET: CITY OF TIGARD DISTANCE BETWEEN DOORS = 48'--6" , Approved by Planning Date: 7 /f z/o, Initials: "''`/i CODE SUMMARY PLAN VICINITY SAP T1.4 1/16"=1'-0" JOB N0. 2080243.39 NORTH PERMIT SETS C?6/29/1f 20$024339\4_DRAPSNGS\ARCHITECTURAL\39-T1A.OWG SYS 06J29/18 10:08 1:96.00 GENERAL NOTES LEGEND A. DIMENSIONS REFLECT FACE OF FINISH.TO FACE OF FINISH, UNLESS NOTED OTHERWISE. Architecturew Interiors { OFFICE OFFICE 6?_©FFICE CONFERENCE B. WALL THICKNESS ARE NOMINAL, UNLESS NOTED.OTHERWISE. EXISTING: WALL TO REMAIN FS{ 406 405 404 403 C. COORDINATE ELECTRICAL REQUIREMENTS WITH OWNER, ALL ELECTRICAL- DRAWINGS Planning Engineering { WILL BE BY DEFERRED SUBMITTAL. W UNDERSIDE RID, SE A8.1 NEW ALL TOOF G E 1 j OFFICE { D. ALL NEW INTERIOR WALLS TO GO TO UNDERSIDE OF GRID UNLESS NOTED OTHERWISE. - EXISTING: ? HOUR RATED WALL TO REMAIN 408 { 4 4 4 E. ALL NEW INTERIOR DOORS TO BE SOLID CORE FLUSH WOOD DOORS TO MATCH EXISTING: J 406A 405A 404A -- -- ~----~ --~- F. OUTLETS INDICATED ARE EXISTING UNLESS NOTED OTHERWISE. CONTRACTOR TO FIELD VERIFY EXISTING DEMISING WALL TO REMAIN 408A AND CONFIRM ADDITIONAL REQUIREMENTS WITH OWNER. EXISTING PARTIAL HEIGHT WALL TO REMAIN Portland,OR OPEN �.:�;. ; .:. .;ati.;T3 :<.•. :,�...;; .::<:• :,�}�, } �: 4o3A OFFICE '; '`"'" .''..z.:""'`` ti J G. LOWER VOC PAINT SYSTEMS TO BE UTILIZED, TO INCLUDE PRIMERS AS WELL AS FINISH PRODUCTS. 503.224.9560 Vancouver,WA 3 { H. VERIFY AND CONFIRM ALL DIMENSIONS AND CONDITIONS PRIOR 70 START OF WORK. ''-- EXISTING OUTLET AND TELEPHONE/DATA OFFICE ) 409A r: >'• •�" :, :•_ - • ";�' '' 11 J I. PATCH AND REPAIR EXISTING WORK DAMAGED DURING CONSTRUCTION TO NEW CONDITION. 360'695'7879 409 ';:; {" :•`�: • ' ' :: =rt: { J. MECHANICAL, ELECTRICAL AND PLUMBING DESIGN/BUILD BY OTHERS: �� NEW OUTLET AND VOICE/DATA ROUGH IN LOCATION Seattle,WA 206.749.9993 K. REUSE ALL DEMOLISHED COMPONENTS WHERE POSSIBLE. SERVICE OR REPAIR TO PROVIDE NEW QUADRUPLEX OUTLET OPEN OFFICE J 'LIKE NEW OPERATION AND APPEARANCE. r; www mcknze.com DEMOLISHED OUTLET AND TELEPHONE/DATA L. . THE CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE OR REQUIRED CLEANING _. ^' '' .'. �.�`.' .'}�' _ ! ! - . C ) MACKENZIE, a;.� =' 'x.,... ' yyyy THROUGHOUT THE STRUCTURE DEEMED TO BE THE RESULT OF THEIR WORK. THE t EXISTING BASE FEED 2 CIRCUITS 'ar=+=L •••" �• - "• �- ��,.�_: i - CONTRACTOR WILL CLEAN UP ALL AREAS AFFECTED BY DUST OR ANY MATERIALS, , - - DESIGN DRIVEN 1 CLIENT FOCUSED :�:,;��:� - $READ: `' _ -� = J CONFERENCE EXISTING FLUSH FLOOR ELECTRICAL AND DATA ROUGH IN LOCATION )C41 _ BOTH DURING CONSTRUCTION AND UPON COMPLETION OF THE PROJECT.PHONE CLOSET 41 :: { ., ':' : ; .' ,AREA' .-•CLOSET• 402 Client X15.' ; 416 ' • . . M. ALL DIMENSIONS SHOWN AS PLUS/MINUS (f) ARE FOR GENERAL LAYOUT AND REFERENCE ONLY. r :,OFFICE411 414 ::: :: .:.Y .. ,,TD EXISTING DEDICATED QUADRUPLEX OUTLET 411A VERIFY AND CONFIRM ALL DIMENSIONS AND CONDITIONS PRIOR TO START OF WORK.� �' fIm 111 nU 402A 7NOTIFY ARCHITECT/ENGINEER OF ANY DISCREPANCIES PRIOR TO START OF WORK. EXISTING FIRE STROBE N. THE CONTRACTOR SHALL COORDINATE .MECHANICAL, ELECTRICAL AND FIRE SPRINKLER DRAWINGS_ _.—_ —...,.,......... � NEW LIGHT SWITCH WITH OCCUPANCY SENSOR r WITH ARCHITECTURAL TENANT IMPROVEMENT DRAWINGS. ADVISE ARCHITECT/DESIGNER PROMPTLY EXISTING LIGHT SWITCH 8 { OF ANY CONFLICTS BETWEEN DISCIPLINES. CB RICHARD ELLIS RECEPTION { 0. PROVIDE SOUND ATTENUATION BATT AT ALL NEW AND EXISTING WALLS. 401 L_.._—,—_ � KEY NOTE FOR REFERENCE P. THE CONTRACTOR SHALL SUPPLY ALL ADDITIONAL DRAWINGS AND SPECIFICATIONS REQUIRED 1 FOR ALL OTHER PERMITS. J Q. THE CONTRACTOR SHALL PROVIDE ADEQUATE PROTECTION OF ALL FURNISHINGS, FINISHES, 200A DOOR NUMBER SYMBOL I} ORK COPY 401A a BUILDING STRUCTURE, EQUIPMENT, , AND SYSTEMS AS REQUIRED. 412 R. TENANT DOOR HARDWARE SHALL BE BUILDING STANDARD, IF APPLICABLE, WITH FINISH TO r 7'� EXISTING LVT TO REMAIN Project 413A 412a MATCH BUILDING STANDARD. L SUITE 4r�0/ 0 S. THE CONTRACTOR SHALL CAREFULLY EXAMINE CONSTRUCTION DOCUMENTS FOR THE WORK. '�> ` NEW LVT LOCATION, SEE SPECIFICATION TENANT IMPROVEMENT ANY CONFLICTS, INCLUDING BUT NOT LIMITED TO BUILT CONDITIONS OF M.E.P. AND FIRE ALARM TORAGE IT IN THE PLANS SHALL BE CALLED .TO THE ATTENTION OF THE ARCHITECT/DESIGNER PRIOR TO 413 OF A COST FOR CONSTRUCTION, SO THAT THE CLARIFICATION CAN BE ISSUED. EXISTING CEILING GRID TO REMAIN " T. COORDINATE ELECTRICAL REQUIREMENTS WITH TENANT, ALL ELECTRICAL DRAWINGS ITMNCLE III WILL BE BY DEFERRED SUBMITTAL. NEW OR RELOCATED SUSPENDED LIGHT FIXTURE, FLUXWERX PROFILE 1322 SE 6M PARKWAY U. HVAC CONTRACTOR TO PROVIDE FULL SHEET OF THE FLOOR AFFECTED UPON COMPLETION. FINISHES TO MATCH EXISTING. 'nGARD, OR 97223 CONTRACTOR IS RESPONSIBLE TO PROGRAM THE OVERRIDE HVAC BUTTON _ rT� P'ARTIAL FOURTH ( PLAN V. LIGHTING LAYOUT IS SHOWN FOR PRELIMINARY_DESIGN INTENT ONLY. �� 0 o EXISTING:DECORATIVE PENDANT LIGHT .FIXTURE TO REMAIN + FINAL LIGHTING LAYOUT IS DEPENDANT ON OREGON ENERGY CODE ALLOWANCES AND �V �AV) 1/8»=)'-0" EXISTING BUILDING INFRASTRUCTURE IN CEILING. EXISTING EXIT SIGN TO REMAIN W. IF SEISMIC UPGRADE IS NECESSARY, ONLY EVALUATED/APPROVED SHOT–IN ANCHORS 3041 ALLOWED FOR USE IN SEISMIC OVERHEAD INSTALLATION. . CONTRACTOR TO SCHEDULE - "- EXISTING UNOERGOUNTER LED LIGHT FIXTURE TO REMAIN P ALTO SPECIAL INSPECTIONS REQUIRED BY CODE IF USING SHOT–IN ANCHORS. ►—� 0 EXISTING RECESSED SQUARE CAN LIGHT FIXTURE TO REMAIN X. SUSPENDED ACOUSTICAL TILE CEILINGS AT 9 —0 t (EXISTING) AFF, LINO.. ORTUIND, 4 E60N , Y. PROVIDE OCCUPANCY SENSORS AT ALL ENCLOSED ROOMS AS REQUIRED BY CODE. L EXISTING LITHONIA 2x4 LIGHT FIXTURE TO REMAIN EXISTING TRACK LIGHTING FIXTURE TO REMAIN OF Q ' Q MACKENZIE 2016 OFF vrriLtx ALL RIGHTS RESERVED 4C6 4 5 04 O THESE DRAWINGS ARE THE PROPERTY OF MACKENZIE AND ARE NOT TO BE KE.. i 1VC)TES USED OR REPRODUCED IN ANY MANNER, F; C WITHOUT PRIOR WRITTEN PERMISSION - 4, 8 �; 1. CENTER NEW WALL WITH EXISTING COLUMN. REVISIONS: OPE 2. ALIGN NEW WALL WITH EDGE OF EXISTING COLUMN. z ' IC cI I 3. ALIGN NEW WALL WITH EXISTING WALL. REVISIONS REVISION DELTA FF 4. NEW 6'x4' BUTT GLAZED RELITES, SEE ELEVATION 2/A8.10 SHEETft CLOSING DATE F; C 10 10 5. EXISTING LVT TO REMAIN. ° ° 6. PROVIDE NEW LVT TO MATCH EXISTING, ALIGN WITH EDGE OF WALL. O 0 a 7. PROVIDE POWER/DATA AND BACKING FOR TENANT PROVIDED TV. OP N 8. INSTALL LOCK ON BOTTOM CABINETS UNDER THE BREAK ROOM SINK. 4 7 9. INSTALL NEW GARBAGE DISPOSAL .AT THE BREAK ROOM SINK. 10. ELECTRIC OUTLETS/DATA AT CEILING FOR TENANT PROVIDED WI—FI. ON Ef3 N E 11. PROVIDE NEW LVT TO MATCH EXISTING, ALIGN WITH OUTER EDGE OF DOOR FRAME AT OFFICE 404. PH ONE' CO T RA CL SET 0 F IC 11 41 41 16 AREA OF WORK SHEET TITLE: PARTIAL FOURTH FLOOR PLAN, RECEPTION -Rkd t : =r REFLECTED CEILING k PLAN, KEY PLAN s ; � TaAND NOBS a� a r 5xr %OR O ,: f "tit�{n'ar,. S•F s«`,a s res 5rr t '? -t,s.,.r. s:..�'. � .35 +�xi N4.,1('' . i.'- s.:(•c a a. y'... 'asap'. �j� ' DRAWN BY:AG SYB CHECKED BY: DMR, PPA 13 L_r SHEET: A2ml 2 PARTIAL FOURTH FLOOR REFLECTED CEILING PLAN 3 KEY PLAN A2.1A2.1 ry Ts JOB N°'2080243.39 NORTH PERMIT SET: 06/29/16 208024339\4 DRAWINGS\ARCHITECTURAL\39-A2.1.OWG SY8 06/29/16 09:33 1:96.00 - ATTACH FRAME AS PER ATTACH CHANNEL AS PER SOUND ATTENUATION BATT AS OCCURS 3 MFR RECOMMENDATIONS TYP; 4 MFR RECOMMENDATIONS TYP GYP BD WALL AS OCCURS HOLLOW MTL KNOCK A8.2 ATTACH STUD TRACK DOWN FRAME, TYP _ THROUGH GRID TO 12" 6'-0" t / BRACE ABOVE - SUSPENDED CLG -ASSEMBLY / / '�----DOUBLE STUD AT JAMB, TYP Architecture * Interiors 45 3 Planning ■ Engineering A8.1 o TIMELY HOLLOW MTL KNOCKDOWN CUT TILE FOR TIGHT 25 GA 3 1/2" METAL STUD BRACING j / / _ FRAME; MATCH BLDG STD FIT AT WALLS TO FLOOR STRUCTURE AT 8'-0" OC W/ (2) #8 SHEET METAL z v CASING BEAD USG 200-A �� Portland,OR GYP 8D EA SIDE SCREWS AT EACH END. BRACING p 503.224.9560 TO BE PROVIDED WHERE DISTANCE Vancouver,WA SOUND ATTENUATION BETWEEN PERPENDICULAR INTERSECTING m 360.695.7879 AT ALL NEW WALLS, TYP. WALLS OR HORIZONTAL BRACINGAV cr w p� � - Seattle,WA BETWEEN WALLS EXCEEDS 8'-0" OC o o 206.749.9993 METAL STUDS METAL STUDS SEE WALL HEIGHT w = www mcknze.com w v TEMPERED ¢ . GYP BD EA SIDE TABLE FOR GAUGE AND SPACING m BUTT GLAZING C Z I E CONT ACOUSTIC �+ SEALANT .,� M A KEN _ EA SIDE AGAINST TRACK - �.,,,� - - DESIGN DRIVEN 1 CLIENT RQCUSED NO SEALANT AT SIM COND - " BUTT GLAZED SIDE LIGHT AS OCCURS Client 1/2" MAK FIN FLR 1/4" TEMP GLASS BOTTOM TRACK TO FINISH SEE DOOR CONCRETE SLAB FLOOR W/ POWDER DRIVEN SCHEDULE ANCHORS AT 4'-0" OC A FLUSH DOOR W RELITE cy ; C: E N CBS RICHARD ELLIS ri` NOWBEARING WALLK2`� DOOR ASSEMBLY w 3 TYP INTERIOR DOOR �8-1AT FLOOR AND SUSPENDED CEILING 3-=I'-O- Cf A .�I 1/2 -1 -0 o AS.I HEAD SIMILAR 3 =1 -Q 4 z o Project SUITE 440/454 TENANT IMPROVEMENT ATTACH STUD TRACK pp R Q O. M FINISH - SCHEDULE THROUGH GRID TO DOOR SCHEDULE / BRACE ABOVE DOOR DOOR DOOR FRAME HD WR FLOOR BASE N. WALL E. WALL S WALL W. WALL CEILING SUSPENDED CLG �' / / DOOR OPENING SIZE THK TYPE MAT'L FINISH MAT'L FINISH DETAILS GROUP RATING COMMENTS OOM ROOM NAME MA MAT'L MAT'L MAT'L MAT'L MAT'L CEILING FINISH TFIANGLE III ASSEMBLY ` '� / / 401A 3'-0"x8'-0" EXISTING DOOR 1 NO FINISH FINISH FINISH FINISH FINISH FINISH HT' MAT'L COMMENTS 13221 68TH PARKWAY 402A 3'-O"x8'-O" EXISTING DOOR --- 401 RECEPTION EXIST EXIST EXIST EXIST EXIST EXIST OTS -- -- TIGARD, C)R 97223 45' 403A 3'-0"xB'-O" EXISTING DOOR -- 402 CONFERENCE EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST -- - 404A 3'-0"x8'-0" IX" FL/R SC S HMK FF 31A8.1 H-1 -- 2 403 CONFERENCE EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST -- CUT TILE FOR TIGHT 25 GA 3 1/2" METAL STUD BRACING 405A 3'-o"x8'-O" i FL/R SC S HMK FF 31A8.1 H-1 -- 2 404 OFFICE EXIST RB GL P P GBP GBP EXIST EXIST A 406A 3'-O"x8'-0" 1-X" FL/R SC S HMK FF 3 A8.1 H-1 -- .2 405 OFFICE EXIST RS GL/P G8/P GB/P GB/P EXIST EXIST A FIT AT WALLS EACH END AND CENTERLINE OF NEW 3041 v OPENING 408A 3'-0"x8'-0" EXISTING DOOR -- 406 OFFICE EXIST RB. GL/P GBP GBP GBIP EXIST EXIST A �' 40REGON'. O ] 409A 3'-O"x$'-O" EXISTING DOOR 407 OPEN OFFICE EXIST R8 EXIST GB/P EXIST EXIST EXIST EXIST A C� 5/8" GYP BD. - 408 OFFIGE EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST -- 410A 3'-0"x8'-o" EXISTING DOOR --- 411A 3'-O"x8'-O" EXISTING DOOR -- 409 OFFICE EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST -- i ORTLAND, � BOX HEADER W/ (2) 412A 3'-0"x8'-0" EXISTING DOOR 1 410 OFFICE EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST -- -GYP BO 413A 3'-0"x8'-O" EXISTING DOOR --- 411 PHONE EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST 362T20 -43 AND (2) 414A 3'-0"x8'-0" EXISTING DOOR -- 412 WORK COPY EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST �-- ' OF Og' 362T2Q0--43 W/#10 SCREWS \—GLAZING CHANNEL 416A 3'-O"x8'-O" EXISTING DOOR 413 STORAGE IT EXIST EXIST EXIST EXIST EXIST EXIST EXIgT EXIST -- C�D16" O.C. — TEMPERED GLAZING - 414 CLOSET EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST -- HARDWARE GROUPS: ABBREVIATIONS: 415 BREAK AREA XIST/LVT- RB GB/P EXIST EXIST EXIST EXIST EXIST A Q MACKENZIE 2016 EXIST EXISTING ALL RIGHTS RESERVED WALL BEYOND H-1: LOCKING OFFICE 416 CLOSET EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST -- THESE DRAWINGS ARE THE PROPERTY LOCKSET F82 GRADE 1, FF FACTORY FINISH 417 OPEN OFFICE EXIST EXIST GB/P EXIST EXIST EXIST EXIT EXIST A OF MACKENZIE AND ARE NOT TO BE ' BUTTS, SEAL, STOPS FL/R FLUSH DOOR WITH ADJACENT RELITE USED OR REPRODUCED IN ANY MANNER, A FL FLUSH FINISH SCHEDULE NOTES: ABBREVIATIONS: WITHOUT PRIOR WRITTEN PERMISSION HMK. HOLLOW METAL KNOCKDOWN A. PATCH, REPAIR, AND PAINT ALL EXISTING WALLS WHERE EXIST EXISTING m S STAIN AFFECTED BY NEW W GB GYPSUM BOARD REVISIONS: SC SOLID CORE WOOD . � E WORK. PAINT.NEW WALLS. GL GLAZING �a K`4BUT/ ;LAZING HEAD CONDITION j Lvr LUXURY VINYL TILE 5-j THIS REVISIONS REVISION DELTA 1 7/2"=1'-0" �c s�, THIS CLOSING DATE ww SHEET A8+1 DOOR SCHEDULE COMMENTS. DOOR SCHEDULE NOTES: PS PAINT TO STRUCTURE 1. EXISTING<DOOR AT EXISTING A. ALL DOORS/CLOSURES TO BE CHECKED, ADJUSTED, RB RUBBER BASE p RATED CORRIDOR AND/OR REPLACED TO BE IN. COMPLIANCE WITH ADA LIMITING WALL HEIGHT TABU 2. CHERRY FINISH B. ALL SECONDARY DOORS TO HAVE DEADBOLTS REMOVED, INTERIOR NON STRUCTURAL COMPOSITE WALLS L/240 0 5psf INSTALL COVERPLATES OR CHANGE DOORS AS AVAILABLE DESIGNATION SPACING MAX WALL HEIGHT C. ALL'DOORS, FRAMES AND HARDWARE TO MATCH TENANT BUILDING STANDARDS. 362S125-18 24" 13'-5" SECTION 09 65 00 - RESILIENT FLOORING 362S125-18 16" 14'-4" 1. RESILIENT FLOORING LVT-1: DEVINE CONTRACT, PRESS IN PLACE, DEVINE SHERWOOD OAK,' 30-05 PLANK 99919—C. SHEET TITLE: 362S162-33 16" 16'-5" NOTE: PROVIDE METAL TRANSITION STRIP BETWEEN MATERIALS. BRICK INSTALL. DETAILS AND 362S162-43 16" 18'-0" 2: RUBBER BASE SCHEDULES 60OS162-33 16" 24'-6" RB-1: FLEXCO 4" STRAIGHT BASE 9ITEF�OR NON STRU=RAL COMPOSITE WALLS L/36o c� 5psf WITH CERAMIC TILE FACING DESIGNATION SPACING MAX. WALT_ HEIGHT SECTION 09 90 00 — PAINT AND COATINGS 1. P-1: BENJAMIN MOORE PM-3 DECORATORS WHITE (GENERAL PAINT) 362S125-18 16" 12'-4" 362S125-33 16" 14'-3" NOTE: NO VOC, LATEX SATIN PAINT TO BE USED ON GYPSUM BOARD WALLS DRAWN BY: SYB UNLESS NOTED OTHERWISE. CHECKED BY: DMR, PPA SHEET: WALL TABLES ARE BASED ON WALLS SHEATHED BOTH SIDES FULL HEIGHT WITH 1/2" GYPSUM BOARD ATTACHED WITH #6 SCREWS MIN. AT 12"-0" O.C. MAX. m -A8,1 F-- ' cz�a JOB NO * 0. WALL HEIGHT TABLE _ 200243. A8.1 Q PERMIT SET: 06/29/16 3 208024339\4_DRAWINGS\ARCHITECTURAL\39-AS.I.DWG SYB 06/28/16 16:29 1:1.00 I