Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans (3)
BUP2016 00216 { 's IRIEC EIVE P JUL 5 2616 IT 11" IV` Architecture Interiors i - - Planning n Engineering <---TO PORTLAND CARMAN DR. 1-5 EXIT#291 t (� �► r r `�`'^► # c� Portland,OR _ -....... 503.224.9560239 23�o- TENANT IMPROVEMENT Vancouver,WA OREGON ACIrr 360.695.7879 - (2401 g BUSINESS Beattie,WA 8----�--� 238z� PARD I[ {,; PACIFICCORPORE CENTER BUILDING 4 206.749.9993 wwv+r.mcknze.cam 18 HOME _ t ) 242 72{24 ) { { �{ DEPOT _ 15353 SW SEQUOIA PKW M AC K E N Z 1 E. DESIGN DRtYiN !CLIENT FOCUSED GO -d _ C PORTLAND OREGON ._ _ 2 ) � PACIFIC FIC { 15 _ - � - (233) - {228) - g� (211 (112) ..�1 � � INDEX OF DRAWINGS CORPORATE c2�2) s == {2a,) � _ � 4 � - {2, t, CENTER _ 3 (210) `., - T1.1 SITE MAP, KEY PLAN AND NOTES - T1.2 PROJECT SPECIFICATIONS {229) zSV 7275 A2.1 PARTIAL FIRST FLOOR PLAN, SCHEDULES AND NOTES - �Usuuuuu>uuusuua,uuuxnruwutuu�uil r A5.1 ENLARGED TOILET ROOM FLOOR PLAN, DETAILS, ELEVATIONS AND NOTES ►rir A5.2 CABINETRY ELEVATIONS AND DETAILS - I__.,_ A6.1 PARTIAL REFLECTED CEILING PLAN AND NOTES FhOlTz . °" A8.1 DETAILS SITE, BUILDING 4 A8.2 DETAILS AND WALL ELEVATION 1 } A8.3 OVERHEAD DOOR DETAILS SITE MAP A8.4 OVERHEAD DOOR DETAILS T1,1 NTs } TRUE SCOPE OF WORK I NORTH THE SCOPE OF WORK FOR THE PROJECT INCLUDES INTERIOR TENANT IMPROVEMENTS FOR AN APPROXIMATELY 9,425 SQUARE FOOT TENANT ON .THE FIRST FLOOR. WORK TO INCLUDE NEW WALLS, DOORS, RELITES AND CABINETRY. } TENANT APPROVAL.` Project OFFICE "B" LONGEST COMMON PATH OF EGRESS INSPIRED.RESULTS OCCUPANCY PATH OF EGRESS 44" MIN,. PROVIDESUITE 100 i TRAVEL = 48'-10" CODE COMPLIANT LIGHTING DESIGN/CODE DATA TENANT IMPOROVEMEN GOVERNING CODE: 2014 OSSC EXIT EX OCCUPANCY: B CONSTRUCTION TYPE: TYPE III--B EOLC*G 4 TENANT AREA (APPROX): APPROX. 9,425 S.F. FULLY SPRINKLED 1 3 SW S_EOU014_P`KW ? OCCUPANCY LOAD: 95 , OREC;OM 2 REQUIRED EXITS, 3 EXITS PROVIDED ALL EXITS ARE EXISTING AND HAVE APPROPRIATE EXIT SIGNAGE F�w BUILDING IS FULLY SPRINKLED J f , - �„'� ^€�� F' �: '*� �.`'v`tsa ,,,,+x.��'�y .�, °'�:>sc"�,.is�yc..'�'�.."u,,a.�S-£^.' .>�. �' ADii1`{f .. 1 ;1 . r10- -•. - ��,.�"�-+ �"` �,�. DEFERRED SUBMITTAL � A',•1 ,1'r�,'� 3 -�, '�- ,.s.`��£�- -_ .rte` _ - �'� ,'. ! ti_ • .i.t+-a}i4 �'},y. _ 2014 OSSC SECTION 107.3.4.2 (by separate permit) r' FIRE SPRINKLER NSI 5 0 FIRE ALARM MECHANICAL ELECTRICAL a � PLUMBING `�, E.;� EXIT MACKENZIE 2016 <Ys '° '� EXIT ILLUMINATION Q ALL RIGHTS RESERVED ,.� � ate '" 3+ :. .s*'2"�•s �` :*' --.`� THESE DRAWINGS,ARE THE PROPERTY . " _ < _-� MACKENZIE AND ARE- NOT TO BE USED � r ����{ � � __ s �i� -•�� .; ,�.,:�.� : -� .�,�; NOTE: DESIGN BUILDERS FOR M.E.P. AND FP. ARE FULLY.RESPONSIBLE FOR THE DESIGN OR REPRODUCED IN ANY MANNER,. H S / OF THESE SYSTEMS/COMPONENTS. THESE SYSTEMS COMPONENTS SHOWN ON DOCUMENTS WITHOUT PRIOR WRITTEN PERMISSION SYSTEMS/COMPONENTS I <: r -`°�`; Sfi� spa" ',:c...,+x�r ry .`� �s .�-: .r... may, - _: - ,, �� REPRESENT ARE SCHEMATIC ONLY, THEY ARE NOT INTENDED TO S FINAL fCODE CUMPIIANT DESIGN. PROVIDE DESIGN DOCUMENT SUBMITTAL REVISIONS: S MI A! TO ARCHITECT OF RECORD FOR REVIEW i �xs PRIOR TO sUBM1TTAL 'a % RI"VISION3tEYiSiON. DELTA 5*t-c 1..L..> �. •tzy,xa. }+•w-. . �5. ' -3" c* w �. >t"` '3v,G '" � 6 THIS CLOSING DATE GHEE JrrS.GT 4 �<,.y��<��s zs'-.., Tt £�`~`.x*,• ,s:,mac-'�-.t --,.7..-< "S-'."�y`.>n.sr',*",�.s r��+ �„�,- "-,>"'�i ,,. *sx,,"" •�G-' z'.' PLUMBING. CALCULATIONS 1 n x PLUMBING 95 OCCUPANTS TOTAL. 1 1 PER TABLE 2902.1, 1 PER 25 FOR THE FIRST 50 AND 1 PER 50 FOR THE REMAINDER 95 OCCUPANTS j 2 — 48 CITY OF TIO.ARD 2 REQUIRED WATER CLOSET FIXTURES PER SEX REVIEWESHEET TITLE:D FOR CODE COMPLIANCE 3 WATER CLOSETS ARE PROVIDED FOR WOMENAPPraved: [ = SITE. MAP, KEY PLAN 2 WATER CLOSET AND 1 URINAL ARE PROVIDED FOR MENpTC; Ll� AND NOTES LAVATORYi REQUIREMENTS: 1 PER 40 FOR THE FIRST 60 Permit#: Address: Gt��2Q r � 2 REQUIRED lAVATORIE5 PER SEX - 2 LAVATORIES ARE PROVIDED FOR WOMEN Suite M r 2 LAVATORIES ARE PROVIDED FOR MEN By., Date: f OFFICE COPS' DRAM BY: ALC ' 2 KEY PLAN 3 CHECKED BY: MRT, AJS T1.1 FIRST FLOOR SHEET: PLAN i NORTH CITY OF TIGARD r Appra�reu b Planning T115.1 INSPIRED RESULTS z Date: 7 SZ 14 Initials: 1416 _ JOB NO. 2160267.03 Pr7r1k Arr r 1r"r. :PNQ/nn lin i _ .. - - 2 _ 01 00 00 GENERAL DATA 09 21 00 GYPSUM BOARD I I 110 00 00 SPECIALTIES HVAC-BID PROCEDURE I I 1 6. EXIT LiGHTS:RUUD LIGHTING"PLASTIC LED EXiT SIGN"MODEL EXPBURWH RED LETTERS WHITE HOUSING . GENERAL REQUIREMENTS GENERAL, f 10 28 13 REST ROOM ACCESSORIES(MULTI OCCUPANCY,) 1. FOR BIDDING PURPOSES,THE HVAC CONTRACTOR WILL ASSUME THAT EXISTING HVAC EQUIPMENT IS IN WITH BATTERY BACKUP. r ' A PROPER WORKING ORDER. 7 4. ALL GYPSUM BOARD WALLS: ONE LAYER 518"TYPE X GYPSUM WALLBOARD,EITHER AT RIGHT ANGLES OR 1. NOT USED, . WHERE NEEDED.CONTRACTOR TO FURNISH AND INSTALL NEW DRY TYPE TRANSFORMERS TO PROVIDE~ 1. ALL CONSTRUCTION WORK SHALL BE DONE IN COMPLIANCE WITH THE LATEST EDITION OF THE OREGON 2. INVENTORY EXISTING H.VAC.ROOFTOP UNITS AND IT TO ARCHITECT CONDITIONS . PARALLEL TO FRAMING ON EACH SERE OF METAL STUDS SPACED AT 24"O.C. FASTEN WITH 1"TYPES O 1 SUBMIT ARC ETEC A Cp DI EONS REPORT OF EACH 2O8V1120V POWER FROM THE 4$OV/277V SYSTEM. SIZE TO BE BIDDER DESIGN, STRUCTURAL SPECIALTY CODE,INTERNATIONAL BUILDING CODE AS AMENDED BY THE STATE OF 2, PAPER TOWEL DISPENSER AND WASTE SEMI RECESSED(ONE PER REST ROOM}8OBRICK 8-3944 UNIT DRYWALL SCREWS 8"O.C.TO VERTICAL EDGES AND 12"O,C.TO TOP AND BOTTOM RUNNERS AND WASHINGTON,AND ALL OTHER STATE OR LOCAL CODE REQUIREMENTS THAT APPLY. I a. TRANSFORMERS TO BE ENERGY STAR LABELED. INTERMEDIATE STUDS, STAGGER ALL VERTICAL AND HORIZONTAL JOINTS 24"O.C.(OR ONE STUD SPACING), < 3. TOILET PARTITIONS:POWDER COATED STEEL,FLOOR ANCHORED WITH CONTINUOUS BRACKETS,FULL 3, LIST TONNAGE OF EACH UNIT, 2. VERIFY ALL DIMENSIONS AND CONDITIONS SHOWN ON DRAWINGS AND AT THE EXISTING BUILDING AND EACH SiDE AND OPPOSITE SIDES. CANTILEVER ONLY. NO CEILING ATTACHMENT OR HEAD RAIL OVER DOORS.ACCURATE OR APPROVED. b, CASE TO BE TOTALLY ENCLOSED WiTH LOUVERS TO PREVENT FOREIGN OBJECTS INTO THE INTERIOR. 1. NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO STARTING THE WORK, S INSTALL USING FACTORY PROVIDE SCREWS ONLY, PROVIDE BACKING 1N WALL TO SUPPORT WALL HVAC-DESIGN PROCEDURE . 5, ALL OFFICE GYPSUM BOARD TO RECEIVE ONE TAPE COAT AND TWO FINISH COATS WITH SANDING BETWEEN 4. ENCLOSED AND VENTILATED,AIR COOLED TYPE,CLASS H INSULATION,DESIGNED FOR II 5 DEGREES C 3. CONTRACTOR AND ALL SUBCONTRACTORS SHALL PERFORM DUE DILIGENCE INSPECTION OF ALL EXISTING FINISH COATS. APPLY USG SHEETROCK BRAND FIRST COAT. PAINT AS INDICATED. 1 BRACKETS. USE EXISTING AND/OR NEW EQUIPMENT TO DESIGN MECHANICAL H.V,A.C.SYSTEM PER DESIGN STANDARDS TEMPERATURE RISE ABOVE 40 DEGREES C AMBIENT TEMPERATURE AT FULL LOAD CONTINUOUS CONDITIONS PRIOR TO SUBMITTAL OF A PROPOSAL.SUBMITTAL OF A PROPOSAL SHALL BE CONSIDERED 1 4. LAVATORY MOUNTED SOAP DISPENSER 34 FL OZ„6"$POUT LENGTH BOBRICK B-8226(ONE AT EACH SINK) LISTED BELOW, OPERATION. EQUIP WITH 2-1/2 PERCENT ANFC TAPS AND FOUR 2-1/2 PERCENT BNFL TAPS, MAXIMUM • 6, ALL OTHER GYPSUM BOARD TO RECEIVE ONE TAPE COAT AND ONE FINISH COAT WITH SANDING AFTER FINISH, CONFIRMATION THAT SUCH INSPECTION HAS BEEN MADE,AND NO FURTHER COMPENSATION SHALL BE DUE PRIOR TO AWARD OF CONSTRUCTION CONTRACT,H,V,A. CONTRACTOR SOUND LEVEL SHALL BE NEMA STANDARD WITH ISOLATION DAMPERS BETWEEN THE CORE AND COIL COAT. PAINT A5 INDICATED. � 5. TOILET SEAT COVER DISPENSER,SANITARY NAPKIN,DISPOSAL AND TOILET TISSUE DISPENSER BOBRICK 8-357 S C C,C TACTOR SHALL SUBMIT TO ARCHITECT FOR THE CONTRACTOR FOR CLAIMS ARISING AS A RESULT OF FAILURE TO PERFORM SUCH INSPECTION. WOMEN'S MOUNTS IN PARTITION REVIEW AND APPROVAL A FULL DESIGN SCHEMATIC FOR THE TENANT SPACE INCLUDING BOTH ASSEMBLY AND CASE. Architecture w Interiors 7. IN FINISHED SPACES FVRR-OUT BUILDING COLUMNS AND EXTERIOR WALLS WITH 5/8"GYPSUM BOARD OVER f ( ) 4. BY SUBMITTING A PROPOSAL,CONTRACTOR AND ALL SUBCONTRACTORS CERTIFY THAT THEY HAVE : NEWlRENOVATED WORK AND SYSTEMS UNTOUCHED BY THE TENANT IMPROVEMENT AS APPLICABLE. 9. NOT USED. METAL STUDS, 16, TOILET SEAT COVER DISPENSER,SANITARY NAPKIN DISPOSAL AND TOILET TiSSUE DISPENSER BOBRiCK EXAMINED THE SITE AND INCLUDED iN THEIR PROPOSAL ALL WORK NECESSARY TO COMPLETE THE WORK - INCLUDE THE FOLLOWING: Planning RI Engmeering DESCRIBED OR REASONABLY IMPLIED IN THESE DOCUMENTS, THiS INCLUDES BUT MAY NOT BE LIMITED TO 8. PROVIDE ACOUSTIC GASKETS WHERE WALL INTERSECTS STOREFRONT,QUIETJOiNT SHH WHERE WALL B 3574 WOMEN'S (MOUNTS SIDE WALL OF SINGLE COMPARTMENT} 10,LOW VOLTAGE SYSTEMS(TELECOMMUNICATION AND DATA}BY FUTURE TENANT. A MATERIALS AND INSTALLATION DISPOSAL OF EXCESS MATERIALS USEABLE FINISH MATERIALS SHALL BE MEETS MULLION AND QUIETJOINT SHG WHERE WALL MEETS GLAZING,COLOR SELECTED BY ARCHITECT.. 17. TOILET SEAT COVER DISPENSER AND TOILET TISSUE DISPENSER BOBRICK B-347 MEN'S MOUNTS IN a. DUCTING AND SIZES 11,LIGHTING ENERGY MANAGEMENT IS REQUIRED IN ALL BUILDINGS, ' LEFT IN THE TENANT SPACE AS DIRECTED BY PACTRUST CLEANING AND ALL PREPARATION OF SUBSTRATE , PARTITION ( b. SUPPLY AND RETURN LOCATIONS AND CFM AT EACH GRiLL OR DIFUSER )' 9, EXISTING WALLS,REMOVE ALL NAILS,SCREWS,FASTENERS,ETC.LEFT BY PREVIOUS TENANT AND PATCH 1 ) 12.LIGHTING ENERGY MANAGEMENT IS REQUIRED IN BUILDING AREAS 5,000 SF AND LARGER. SURFACES PRIOR TO INSTALLATION,AS WELL AS FINAL CLEAN UP, HOLES READY FOR PAINT. 18. TOILET SEAT COVER DISPENSER AND TOILET TISSUE DISPENSER BOBRICK B-3474 MEN'S (MOUNTS SIDE C. ROOF EQUIPMENT,SIZES AND LOCATIONS it. UNITS REQUIRING DUCTED SM DETECTION 13.OCCUPANCY CONTROL DEVICES SHALL BE LEVITON OR WATT STOP. 1. 5. IT iS DA INTENT OF THESE CONTRACT DOCUMENTS TO MATCH AND MAINTAIN EXISTING BUILDING 10,PSUM BOARD AT REMOVED ELECTRICAL RECEPTACLES OR DATA BOXES AND FINISH READY FOR PAINT $ WALL OF SINGLE COMPARTMENT OKE ETEC ION 1 STANDARDS FOR ALL EXISTING PRODUCTS AND SYSTEMS. UPON DISCOVERY OF A DISCREPANCY TO THIS „ 14,TEST ALL LIGHTING CONTROL SYSTEMS TO ENSURE THAT CONTROL DEVICES,COMPONENTS,EQUIPMENT 9, MIRROR STANDARD SIZES 1/4"PLATE MIRROR WiTH EDGES FLAT GROUND"BOTTOM EDGE SUPPORTED BY A e. THERMOSTAT ,' INTENTION,THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY. 11,REMOVAL OF WALL BASE,REMOVE RESIDUAL ADHESIVE AND PREP WALL TO PAINT READY CONDITION. " „ HERMOS T LOCATIONS AND ZONElUNIT ASSOCIATED THEREWITH AND SYSTEMS ARE CALIBRATED,ADJUSTED AND OPERATE IN ACCORDANCE WITH APPROVED PLANS AND �• I CONTINUOUS BRIGHT CHROME J METAL,5/16 X 3!8 (HEIGHT OF EXPOSED FACE)WITH CONCEALED LEG T N 6. FURNISH ALL NEW MATERIALS EXCEPT WHERE SPECIFICALLY NOTED OTHERWISE. WALL CONSTRUCTION MATERIALS SPECIFICATIONS. SEQUENCES OF OPERATION SMALL BE FUNCTIONALLY TESTED O SCREWED TO THE WALL TO CARRY THE WEIGHT OF MIRROR. f. ANY SUPPLEMENTAL EXHAUST FANS OR SPECIAL SYSTEMS ENSURE THEY OPERATE Portland,OR iN ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. 5Q3 224.9S6ta 7. COORDINATE THE WORK OF ALL TRADES, PROVIDE CARPET"WALK-OFF MATS"TO PROTECT EXISTING 1. PROVIDE STUDS,TRACKS,BRACING.FASTENING AND OTHER ACCESSORIES NECESSARY FOR COMPLETE i I10.GRAB BAR SATIN FINISH BOBRICK B-6806 SERIES g. ZONE DIAGRAM iS.REQUIRED IN DIVISION 15,PROVIDE MONITORING OF HVAC EQUIPMENT PER CODE. Vancouver, � CARPETS. INSTALLATION. 1 10 28 13 BREAK COUNTER HVAC DESIGN STANDARDS W 16.REMOVE ALL UNUSED DATA AND POWER BOXES AND INFILL WITH GYP BOARD. EXCEPTION-UNUSED DATA ' S. NOT USED. 2. FRAMING MEMBERS SHALL HAVE THE STRUCTURAL PROPERTIES INDICATED WHERE PHYSICAL STRUCTURAL THE FOLLOWING ARE MINIMUM DESIGN STANDARDS:' - PROPERTIES ARE NOT INDICATED,THEY SHALL BE AS NECESSARY TO WITHSTAND ALL IMPOSED LIVE LOADS, 11. PAPER TOWEL DISPENSERS,SURFACE MOUNTED(KITCHEN/BREAK ROOM)BOBRICK B-262 L ND S. BOXES UNDER WINDOW SILLS TO REMAIN. ALL BLANK COVER PLATES TO BE BUILDING STANDARD FINISH. 360.695.7579 9. NOT USED. I DESIGN FRAMING IN ACCORDANCE WITH AISI SG-673. 12. CUP DISPENSER-BOBRICK B-235 1. 350 SQUARE FOOT PER TON(UNLESS OTHERWISE APPROVED IN WRITING BY PACTRUST). 17.REMOVE ALL UNUSED LOW VOLTAGE WIRING(TELEPHONE AND DATA)FROM THE RECEPTACLE TO THE Seattle, . iO.KEEP THE AREA OF WORK FREE OF GARBAGE AND DEBRIS ON A DAILY BASES INCLUDING DOCK ACCESS DISTRIBUTION BOARD.LEAVE PULL STRINGS FROM THE BOX TO THE SPACE ABOVE THE CEILING. A SECTION �� AREAS AND COMMON AREA. FLOORS TO BE SWEPT OR VACUUMED DAILY. 3. COLD-FORMED FRAMING SHALL BE GALVANIZED METAL CONFORMING TO ASTM A4461A 446 M GRADE A(33000 1 10 4416 FIRE EXTINGUISHERS 2, ADDRESS LOADS BY SPECIFIC LOCATION AND USE,AS WELL AS CRITERIA PROVIDED TO PACTRUST BY OF THE EXISI7NG LOW VOLTAGE WIRE MAY BE LEFT IN LIEU OF A PULL STRING 206,749,9993 PSI)060. ' 1. FIRE EXTINGUISHER 2,010 SG (WALL MOUNTED OR IN SEMI RECESSED CABINET AS INDICATED ON PLAN} TENANT PRIOR TO CONSTRUCTION: G I I,PROVIDE ADEQUATE PROTECTION TO ALL EXISTING IMPROVEMENTS INCLUDING BUT NOT LIMITED TO I a. EXTERIOR EXPOSURE AREAS OFFICE LIGHTING . 4. PROVIDE THE LISTED GYPSUM BOARD PRODUCTS BY U.S.GYPSUM,GEORGIA PACIFIC,NATIONAL GYPSUM OR WWW.tllGkn2e.COtn COMMON CORRIDORS AND STAIRS,BUILDING ENTRANCES,SUITE ENTRANCES,ETC. THE CONTRACTOR WILL 2, FIRE EXTINGUISHER CABINET: JL INDUSTRIES ACADEMY SERIES MODEL#C1027V10. BE RESPONSIBLE FOR THE REPAIR OF ANY DAMAGES TO EXISTING IMPROVEMENTS DUE TO CONSTRUCTION AN APPROVED EQUAL. I b, INTERIOR AREAS,SIZE AND USE L-1:LiTHONIA,2BLT2 4OLHE ADSMT LP835(OFFICE) 11 00 00 EQUIPMENT ACTiViTiES, 5. STANDARD GYPSUM BOARD SMALL BE TYPE'X',518"THICK WITH TAPERED EDGES CONFORMING 70 ASTM o. CONFERENCE!TRAINING ROOMS L-2:LITHONIA,LDN6 351 10 L06AR(TOILET ROOM) �" w' "'� M C36 i 1. DISHWASHER: GE GLDT690JSS STAINLESS STEAL-ENERGY STAR RATED. M AG K E N Z 1 E• 12.PROVIDE TEMPORARY SANITARY FACILITIES, CONSTRUCTION WORKERS SHALL N07 USE BUILDING i d. COMPUTER/SERVER AND TELEPHONE ROOMS P L-3:FIN LITE S16-LED-ED-DCO-Oft-2E-V-835-OPEN(BREAK&OPEN OFFICE) , RESTROOM FACILITIES. 6. WATER RESISTANT GYPSUM BOARD SHALL BE 518"THICK WITH TAPERED EDGES. CONFORMING TO ASTM E 2. GARBAGE DISPOSAL:WSINKERATOR BADGER V 1/2 HP - E 00 S TO HAVE PROVISION FOR LOW AMBIENT OPERATION Ft AND 24 HOUR USE.VERIFY NEED FOR A SEPARATE SPLIT SYSTEM TO MAINTAIN TEMPERATURE, L-4:FiNELITE S17-LED-ACF-PF-4ft-S-8-35(VANITY) DCS{ON DRIVEN {CI tRNT FOCUSED C 630. 1 3, SYSTEM DESIGN CRITERIA-SIZE ZONES F - 13.STORAGE AND STAGING OF CONSTRUCTION MATERIALS SHALL BE LIMITED TO AREAS AS DESiGNAT£0 AT 12 00 00 FURNISHINGS C Z ES qR 3 5 T UNITS BASED PRE-CONSTRUCTION MEETING. UNDER NO CIRCUMSTANCES SHALL BUILDING UTILITY AREAS OR ANY OTHER 7, AT TOILET ROOMS USE 518"USG FIBERROCK BRAND AQUATOUGH INTERIOR PANEL FROM FLOOR TO 4W A,F,F, ON 5 ON USE& LIT INTO M CRITERIA. L 1. CLEAN!REFURBISH EXISTING BUILDING STANDARD BLINDS AT ALL EXTERIOR GLASS. PACKAGED OR SPOT SYSTEM EQUIPMENT GREATER THAN 5 TONS SHALL BE SPLIT INTO MULTIPLE ZONES. COMMON BUILDING AREA BE USED FOR STORAGE. ON WALLS BEHIND OR ADJACENT TO PLUMBING FIXTURES, NO SUBSTITUTES.(EXCEPTION:EXCEPTION AT ! VAV OR WATER SOURCE HEAT PUMP SYSTEMS GREATER THAN 3 TONS SHALL BE SPLIT INTO MULTIPLE 28 30 00 ELECTRONIC DETECTION AND ALARM LOCATIONS TO RECiEVE PLASTIC LAMINATE OR TILE WAINSCOT.) 1 2. REPLACE BUILDING STANDARD BLINDS AT ALL EXTERIOR GLASS AND PROVIDE BUILDING STANDARD BLINDS ZONES.14.KEEP THE ROOF FREE OF DEBRIS(I.E.NAILS.SCREWS,BOTTLES,ETC.)AT ALL TIMES. GENERAL I TO MATCH AT NEW EXTERIOR GLASS. BLINDS SHALL BE PER CURRENT PACTRUST STANDARD(WHITE, - IS.ALL DIMENSIONS ARE TO FACE OF GYPSUM BOARD UNLESS OTHERWISE NOTED. $' NOT USED. I 9. NOT USED. ' VERTICAL,NON�I-PERFORATED.)CONTRACTOR SHALL VERIFY THE BUILDING STANDARD AND CONFIRM WITH 4. ALL ENCLOSED ROOMS OR OFFICES TO HAVE DUCTED SUPPLY&RETURN GRILLES. FOR HORN/STROBE DEVICES USE"SYSTEM SENSOR"SPECTRALERTADVANCE DEVICES,OR APPROVED EQUAL 16.CONFIRM SiZES OF ALL OPENINGS REQUIRED FOR THE INSTALLATION OF STRUCTURAL,MECHANICAL, THE ARCHITECT BEFORE ORDERING. 5, VACANT SPACE SHALL HAVE DEDICATED GAS SERVICE FOR FUTURE BUILD-OUT OR FREEZE PROTECTION. ELECTRICAL AND PLUMBING WORK PRIOR TO FRAMING OR CUTTING FOR INSTALLATION. 10.TRIM ACCESSORIES SHALL COMPLY WITH ASTM C-1047. 1 13, NOT USED. 6. UNITS: LENNOX,TRANE,YORK OR CARRIER-71/2-TON MAXIMUM UNIT SiZE. ANY UNiT IN EXCESS OF 71/2 171EAVE THE PROJECT CLEAN AND READY FOR OCCUPANCY, I I.USE GEORGIA PACIFIC DENSGLAS GOLD ON EXTERIOR FACE OF EXTERIOR WALLS AND COAT WITH STO FiNISH ' 4, INSTALL BUILDING STANDARD ADDRESS AND/OR SUITE NUMBER LABELS TO ALL EXTERIOR DOORS. TONS SHALL HAVE SPECIAL WRITTEN APPROVAL FROM PACTRUST. 18.CLFAN ADJACENT EXTERIOR AREA.I.E.WALKS,EXTERIOR GLASS,ETC. SYSTEM. 7, HVAC UNITS EQUAL TO OR GREATER THAN 5-TONS TO HAVE DUCT SMOKE DETECTORS AND BE CONNECTED 12 23 16 CABINET SPECIFICATIONS WALL CONSTRUCTION EXECUTION TO A MONITORING STATION WITHIN THE BUILDING. 19.FILL ALL PAPER AND SOAP DISPENSERS IN RESTROOMS AND BREAK AREAS. 11, ALL CABINETRY TO BE INSTALLED OVER FINISH FLOOR AT ALL RESILIENT FLOORING LOCATIONS. , 10.FASTEN FRAMING MEMBERS TOGETHER BY WELDING OR BY USING SELF-DRILLING OR SELF-TAPPING s 8. ROOF TOP UNITS SHALL BE PLACED 24 MINIMUM FROM ROOF EDGE TO CENTER OF UNIT. MULTIPLE UNITS - 20.CLEAN ALL SUPPLY AND RETURN DIFFUSERS AT PROJECT COMPLETION. (co-ordinate with DIV 15) SCREWS. WELDING SHALL CONFORM TO AWS 013 WELDING PROCEDURE, ELECTRODES AND SCREW i 2. AWI CUSTOM GRADE STANDARDS FOR CASEWORK AND COUNTER TOPS U.N,O SHALL BE PLACED SYMMETRICALLY IN A LINE:BASED ON LOAD CALCULATIONS BY STRUCTURAL ENGINEER. , 21.PROVIDE"AS-BUILT"DRAWINGS OF THE WORK AT THE CONCLUSION OF CONSTRUCTION.AS-BUILT" CONNECTIONS SHALL BE AS REQUIRED AND INDICATED IN THE DESIGN CALCULATIONS. DO NOT FIELD WELD HIGH PRESSURE LAMINATE P-LAM HPL ALL EXTERIOR SURFACES INCLUDING 4"TOE KICK. EDGE BANDING DRAWINGS MAY BE IN THE FORM OF TWO COPIES OF CONSTRUCTION DOCUMENTS MARKED-UP WITH RED MATERIALS LiGHTER THAN 18 GA 3• ( } G 9. CURBS: 14"HIGH CURBS. ASSEMBLED AND LEVELED TO ROOF,ANCHORED TO STRUCTURAL MEMBERS (MATCHING PVC ACCEPTABLE),FIN ENDS,DOORS,AND LiGHT VALENCE ETC. UPPER CABINET BOTTOMS BELOW ROOFING. PEN.DELIVER RECORD DRAWINGS TO THE ARCHITECT. COMPLETE OPERATION AND MAINTENANCE MANUALSOPTIONAL HPL FINISH,STANDARD MELAMINE FINISH. OPEN CABINETS OPTIONAL HPL FINISH,STANDARD 11 PROVIDE ACCURATELY ALIGNED RUNNERS AT TOP AND BOTTOM OF PARTITIONS. ANCHOR TRACKS AS SHALL BE PROVIDED FOR ALL MECHANICAL,ELECTRICAL AND PLUMBING EQUIPMENT.PACTRUST MAY HOLD MELAMINE FINISH, a, PROFESSIONALLY ROOF IN ALL CURBS AND PENETRATIONS BY PACTRUST APPROVED ROOF CONTRACTOR'S FiNAL PAYMENT UNTIL"AS BUILT"DRAWINGS AND O&M MANUALS HAVE BEEN RECEIVED INDICATED IN THE DESIGN CALCULATIONS. BUTT WELD JOINTS IN TRACKS OR SPLICE WITH STUD INSERTS. CONTRACTOR. SEE DIVISION 1 GENERAL NOTES THIS PAGE. a Is a : . AND APPROVED. FASTENERS SHALL BE AT LEAST 3 INCHES FROM THE EDGE OF CONCRETE SLABS. 4. TOE KICK PLYWOOD 4"H WtTH P-LAM COVER b NI ST L E L I ` i I I , I I I 1 . I I. -_.-3. 12.CUT STUDS SQUARE AND SET WITH FIRM BEARING AGAINST WEBS OF TOP AND BOTTOM TRACKS. POSITION UNIT MU BE EV L,SEA ED WITH NO AIR LEAKS AND COUNTER FLASHED. I. .. I; R t1y Asopclf�k. L P • 22,17 IS THE INTENT OF THE CONTRACT DOCUMENTS THAT THE CONTRACTOR PROVIDE A COMPLETE, 1 5. DOORS AND DRAWER FRONTS PLASTIC LAMINATE OVER 11/16"PARTICLE BOARD WITH MATCHING P-LAM OR ' FUNCTIONING PROJECT INCLUDING ALL GENERAL,MECHANICAL AND ELECTRICAL CONSTRUCTION REQUIRED STUDS VERTICALLY IN TRACKS AND SPACE AS iND€CATED IN DESIGN. DO NOT SPLICE STUDS, PROVIDE AT I PVC EDGES. c. CONDENSATE MUST BE TRAPPED AT UNIT. TO FULFILL THAT INTENT. ALL ITEMS REQUIRED SHALL BE FURNISHED AND INSTALLED REGARDLESS OF LEAST TWO FULL HEIGHT KING STUDS AT DOORS AND OTHER OPENINGS 2 FEET WIDE OR LARGER. PROVIDE i 10.SEISMICALLY ATTACH UNIT TO CURB IN CODE-APPROVED METHOD. 11 WHE HER OR NOT SHOWN ON THE DRAWINGS. JACK STUDS OVER OPENINGS,AS NECESSARY,TO MAINTAIN INDICATED STUD SPACING. PROVIDE TRIPLE { 6. MELAMINE(LOW PRESSURE LAMINATE/LPL)ALL INTERIOR AREAS,DRAWER PARTS,SHELVING ETC, T STUDS AT CORNERS,POSITIONED TO RECEIVE INTERIOR AND EXTERIOR FINISHES. FASTEN STUDS AT TOP ' 7. FLUSH OVERLAY/FRAMELESS STYLE CONSTRUCTION, 11.ALL GAS PiPING SHALL BE STANDARD BLACK STEEL PIPE W/SUPPORTS PER CODE. PiPING SHALL BE RUN . 23,ITEMS OR WORK NOT TO BE FURNISHED OR ACCOMPLISHED BY CONTRACTOR ARE NOTED"N.I.C.". AND BOTTOM TRACKS BY WELDING OR SCREWING BOTH FLANGES TO THE TRACKS.PROVIDE LONG LEG INSIDE OF BUILDING W/LEAD FLASHINGS A7 ROOF PENETRATIONS. LEAD ROOF JACKS TO BE SEALED AND TRACK AT TOP OF WALL TO ALLOW FOR DEFLECTION WHERE WALL MEETS STRUCTURE ABOVE. 8. HiNGES-BLUM#75M3580,110 DEG.SELF CLOSING CLIP ON(OR EQUAL), CLAMPED(STAINLESS STEEL WORM GEAR). 24."ALIGN"AS USED IN THESE DOCUMENTS,MEANS TO ALiGN THE FINISHED FACES OF ELEMENTS IN THE SAME I PLANE,EITHER IMMEDIATELY ADJACENT TO ONE ANOTHER OR ACROSS AN OPENING. 13.INSTALL ALL INTERIOR AND EXTERIOR GYPSUM BOARD PRODUCTS AND ACCESSORIES AS REQUIRED FOR 19, DRAWER SLIDES-BLUM #230M SERIES EXTENSION(OR EQUAL)75 LBS.MIN.FOR STANDARD DRAWERS. 12.ALL EXISTING AND NEW GAS PIPING EXPOSED TO THE EXTERIOR TO BE PROTECTED FROM RUST AND THE PROJECT. L . ACCUR►DE#4032(OR EQUAL)HD/FULL EXT 150 LBS,MIN,FOR HD AND FILE DRAWERS.. CORROSION WITH OIL BASED PAINT(COLOR GREY), ' 25.DO NOT DISASSEMBLE SETS OF CONSTRUCTION DRAWINGS,DRAWINGS ARE INTERRELATED. L 14.NOT USED, 110.PULLS-96 MM C-TO-C WIRE PULLS. FINISH TO MATCH DOOR HARDWARE. 13.LOW VOLTAGE IN SEALTITE CONDUIT FROM BELOW ROOF LINE DIRECT TO UNIT. DO NOT EXCEED BEND 26.SUBMIT SAMPLES OR DRAW DOWNS FOR ALL FINISHES REQUESTED TO THE ARCHITECT OF RECORD WITHIN E RADIUS OF MANUFACTURER'S GUIDELINE. • TWO WEEKS OF PROJECT AWARD.PRODUCTS INSTALLED WITHOUT APPROVED SAMPLES ARE SUBJECT TO 1$.COMPLY WITH USG GYPSUM CONSTRUCTION HANDBOOK AND MANUFACTURER'S RECOMMENDATIONS. ; 11•GENERAL CONTRACTOR TO PROVIDE CABINET MAKER WITH SINK TEMPLATE(SPEC SHEETS)FOR EACH SINK. REPLACEMENT AT CONTRACTOR COST.AN APPROVED SUBMITTAL DOES NOT CHANGE THE CONTRACTUAL I SINK CUTOUT SHALL BE DONE IN SHOP WHEN FEASIBLE AND BEFORE BACK SPLASH IS INSTALLED IN ALL 14.ECONOMIZER TO MEET CODE AND AS FOLLOWS: " REQUIREMENT TO PROVIDE THE SPECIFIED ITEMS UNLESS SPECIFICALLY NOTED AS A SUBSTITUTION BY THE 16.FINISH QUALITY: CASES TO ALLOW CUT OUT TO BE POSITIONED PROPERLY,'ALL RAW EDGES OF CUT OUT AND BACK SPLASH CONTRACTOR AND SPECIFICALLY APPROVED BY THE ARCHITECT AS SUCH.REPLACE SUCH PRODUCTS AS AREA PROCESS TRADE NOMENCLATURE TO BE SEALED. MINIMIZE COUNTERTOP BUILD UPS AT FRONT AND BACK OF SINK CUT OUT TO a, 6 TONS AND ABOVE MUST HAVE ECONOMIZER, DIRECTED AT CONTRACTOR'S COST. OFFICE/OTHER AREAS TAPE/2 FINISH COATS*1 SMOOTH FINISH TAPED i ACCOMMODATE PLUMBERS SINK CLAMPS CLEARANCE. b. PROVIDE Economizers on all units AS REQUIRED BY WASHINGTON STATE MECHANICAL CODE. . 27,SUBMIT COMPLETE SHOP DRAWINGS FOR MILLWORK,SPECIAL SYSTEMS,MECHANICAL.ELECTRICAL AND 12.KITCHEN/BREAK ROOM CABINETS-BASE CABINET WITH P-LAM TOP ON PLYWOOD DECKING AND 4"BACK c. BAROMETRIC RELIEF ON 5-7112 TON UNITS. _J USG"FIRST COAT- •SAND AFTER TAPE I FINISH COAT(S) SPLASH. ALL CABINETS TO HAVE DOORS AND DRAWERS,U.N.O. UPPERS 12"D X 36 H-ATTACH TO WALL d. 8 TONS AND ABOVE MUST HAVE POWER EX PLUMBING SYSTEMS{INCLUDING FERE PROTECTION SYSTEMS}. SUBMIT A MINIMUM OF TWO COPIES OF ALL p R EXHAUST. SHOP DRAWINGS FOR REVIEW AND APPROVAL TO THE ARCHITECT OF RECORD.ARCHITECT WILL RETAIN ONE 17.FINISH EXPOSED INTERIOR GYPSUM BOARD WALLS AND CEILINGS SMOOTH STRAIGHT READY FOR FINISH AS WITH FRENCH CLEAT,COUNTER AND COUNTERTOPS 26"DEEP. MICROWAVE SHELF 18"D WITH 3"RADIUS 'Project COPY AND ONE COPY WILL BE RETURNED TO THE CONTRACTOR. SHOWN ON PLANS, i OUTSIDE CORNERS. P-LAM AT TOEIBASE. ALL SHELVES ADJUSTABLE.PROVIDE HOLES AND POSTS(1 AT e, 1 112 THRU 4-TON OSA INTAKE WITH DAMPER. BASE,2 AT UPPERS). INSPIRED RESULT 28.THE DESIGN OF FIRE PROTECTION SYSTEMS IS THE RESPONSIBILITY OF THE FIRE PROTECTION SYSTEMS 09 31 00 PORCELAIN TILE _ 15,ALL UNITS TO MEET OR EXCEED CURRENT ENERGY EFFICIENCY CODE REQUIREMENTS. { CONTRACTOR.ALL FIRE PROTECTION SYSTEMS SHALL BE DESIGNED BY A PROFESSIONAL ENGINEER 13,WORK/COPY/STORAGE CABINETS-BASE CABINETS WITH P-LAM TOP ON PARTICLE BOARD DECKING. SCRIBE 16 DROP CANS TO BE SAME SIZE AS CURB OPENING AND TO EXTENDED TO WITHIN 2'OF SUSPENDED COILING. SUITE 1 1. NOT USED. COUNTERTOPS TO WALLS. ALL CABINETS OPEN MELAMINE STANDARD INTERIORS WITH DRAWERS,U.N.O. LICENSED BY THE APPROPRIATE JURISDICTION FOR THE DESIGN OF THIS TYPE OF SYSTEM, COORDINATE MINIMUM 26 GAUGE FOR SUPPLY AIR. SEAL EDGES OF SUPPLY AIR. INTERFACT;WITH EXISTING BUILDING SYSTEMS AND WITH ARCHITECT, ALL SPRINKLER HEADS SHALL BE 2. NOT USED. UPPERS AT 15"a X 30"H -ATTACH UPPERS TO WALL WITH FRENCH CLEAT. BASES AT 24"D X 36"H. P-LAM AT TENANT IMPOROVEMEN CENTERED iN CEILING TILE(OR 2 x 2 MODULE OF A SECOND LOOK 11 TYPE OF CEILING TILE WHERE I TOE/BASE. ALL SHELVES ADJ.HOLES AND POST(1 AT BASE,1 AT UPPERS). ITDiSTRIBUTION DUCTWORK: . APPLICABLE). LOCATION OF THOSE IN GYPSUM BOARD CEILINGS SHALL BE PRE-APPROVED IN WRITING BY 3. FOLLOW MANUFACTURER,LATICRETE,CROSSViLLE AND TCNA PRINTED INSTRUCTIONS FOR TCNA F115 AT ; FLOOR AND BASE. WHERE INSTRUCTIONS CONFLICT,USE MOST STRINGENT. JOINTS TO BE UNIFORM 1/8" 14,WORK COUNTER TOPS-COUNTER TOPS WITH P-LAM ON PARTICLE BOARD DECKING. SCRIBE COUNTERTOPS a. SPIRAL DUCT PERMITTED ONLY IF EXPOSER THE ARCHITECT PRiOR TO INSTALLATION. WIDE AT THE FLOOR TILE.CENTER THE WALL AND BASE TILE JOINTS ON THE FLOOR TILE JOINTSSPACE TO WALLS. PROVIDE GROMMET HOLES ABOVE ALL POWER AND DATA LOCATIONS. PROVIDE STEEL MID SPAN 29.COORDINATE ALL CONSTRUCTION SEQUENCING WITH PACTRUST AND SCHEDULE ALL SERVICE UNIFORMLY AS INDICATED. 1 SUPPORTS AS NEEDED EQUAL TO WORK STATION BRACKETS AS MFG.BY A&M HARDWARE,INC b, 28 GAUGE OR TO SMACNA STANDARDS WHERE DUCT IS CONCEALED ABOVE A CEILING. . INTERRUPTIONS OUTSIDE NORMAL BUSINESS HOURS TO MINIMIZE INCONVENIENCE TO CURRENT TENANTS. 4, PROVIDE SCHLUTER EDGE TRIM APPROPRIATE FOR FINISHES AT TRANSITIONS. PROVIDE PHYSICAL (888-647-0200). c. WRAP CONCEALED SUPPLY DUCTWORK IN NON-CONDITIONED AND SEMI-CONDITIONED SPACE WITH BUL�4 E 15.RESTROOM LAVATORIES(WHERE APPLICABLE)-24"0 P-LAM TOP ON PLYWOOD DECKING WITH 4"H P-LAM MINIMUM R4.2 INSULATION WITH FSK BARRIER, , SW SBQ� � GENERAL SUBMITTAL OF PROPOSED TRIM TO ARCHITECT FOR APPROVAL I BACK SPLASH. 5"H FACE MOUNT AT 34"A.F,F. SEE PLANS IF REQUIRED. d. HANGERS 12 GAUGE WiRE OR 18-GAUGE V WIDE STRAP. EXPOSED DUCT MUST HAVE ALL THREAD 1. NOT USED. 5. CLEAN TILE AND GROUT AND SEAL WiTH MiRACLE SEALANTS$11 IMPREGNATOR SEALER. RESTRICT TRAFFIC i HANGERS AND FULL DIAMETER STRAP UP TO 18"0. LARGER THAN 18"MUST HAVE SADDLE TYPE CLAMP, � OREGON 2. ALL ROOF PENETRATIONS FOR ELECTRICAL,LOW VOLTAGE,GAS PIPING,ETC.SHALL BE SLEEVED THROUGH FOR 4 DAYS AFTER COMPLETION. !21 00 00 FIRE SUPPRESSION : DESIGN/BUILD 1. PROVIDE SPRINKLERS THROUGHOUT SPACE AS REQUIRED BY CODE. SPRINKLER HEADS SHALL BE e, BRANCH DUCTS SHALL BE PLUMB AND SQUARE(NO OCTOPUS), TEES SHALL BE MAXIMUM OF 45 A LEAD ROOF BACK,CLAMPED WITH A STAINLESS STEEL CLAMP AND SEALED WITH VULKEM 921 09 83 00 SusPEI�DEC?ACOUSTICAL CEILING DEGREES, POLYURETHANE SEALANT. SILICONE SEALANT NOT PERMITTED. CENTERED IN 2 X 2 CEILING TILE.LAYOUT OF SPRINKLERS BY CONTRACTOR. SPRINKLER LAYOUT IN ALL HARD 1. COMPLY WITH CURRENT SEISMIC REQUIREMENTS OF THE INTERNATIONAL BUILDING CODE. I CEILING AREAS(GYPSUM BOARD/PLASTER)TO BE REVIEWED AND APPROVED BY ARCHITECT PRIOR TO I. EACH BRANCH DUCT TO HAVE BALANCE DAMPER iN Y BRANCH. � ¢ 01 73 29 CUTTING AND PATCHING INSTALLATION, 4 2. FOLLOW MANUFACTURERS PRINTED INSTRUCTIONS FOR THE DELIVERY AND INSTALLATION OF CEILING g. ALL DISTRIBUTION DUCT WORK TO BE INSTALLED MIN.24"ABOVE FINISH CEILING. a ►' 1, PERFORM CUTTING AND PATCHING WITH SKILLED CRAFTSMEN EXPERIENCED WITH THE TYPE OF WORK SYSTEM,INCLUDING GRID,PANELS,AND HANGARS AND ACCESSORIES, 12, IN NEW CEILING GRID SYSTEMS OVER 144 SF PROVIDE FLEXIBLE HEADS FOR MINIMUM SEISMIC MOVEMENT. - 18.FLEX DUCT WELL BE NO LONGER THAN 6 FROM RIGID DUCT DOWN TO DIFFUSER. �� BEING UNDERTAKEN. 3. USE ALL PRODUCTS FROM ARMSTRONG WORLD INDUSTRIES,INC. d NO"OOPS RiNGS ALLOWED". Z 2. PROTECT EXISTING CONSTRUCTION TO PREVENT DAMAGE. INCLUDING N I 19.DIFFUSERS ADAM J. 0.1 - I... . 4. CO-ORDINATE CEILING WORK WITH INSTALLERS OF RELATED WORK INCLUD G BUT NOT LIMITED TO 13. PROVIDE AUTOMATIC FERE SPRINKLER FLOW INDICATOR SIEMENS CU-MHU-MCS-W OR EQUAL.SEE PLAN FOR 3. PERFORM CUTTING USING METHODS LEAST LIKELY TO DAMAGE ELEMENTS TO BE RETAINED. INSULATION.GYPSUM BOARD,LIGHT FIXTURES,MECHANICAL SYSTEMS,ELECTRICAL SYSTEMS AND FIRE I LOCATIONS. a. SUSPENDED CEILING SYSTEM(T-BAR)-PERFORATED FACE ADJUSTABLE CURVED BLADES-DESIGN r� SPRINKLERS : TITUS PCS SUPPLY AND TITUS PAR RETURN OR APPROVED EQUAL. 08 10 00 DOORS AND WINDOWS 22 00 00 PLUMBING: DESIGN I BUILD a .--.- � . S. PRODUCTS: b. GYPSUM BOARD CEILING:SUPPLY-CURVED BLADE Wi OBD DESIGN TITUS 250;RETURN-BAR TYPE- ,M n ''[},'�REUf '� 1. NOT USED. t GENERAL REQUIREMENTS DESIGN TITUS 350;EXHAUST-METAL OR ALUMINUM-112 x 1/2"EGG CRATE DESIGN TITUS 50F. a, GRID-PRELUDE 24 XL 15116"EXPOSED TEE(HEAVY DUTY} � r 2, APPROVED DOOR,FRAME,AND HARDWARE SUPPLIERS INCLUDE: i 1. CONTRACTOR TO SUBMIT LAYOUT ON ELEVATIONS AND PLANS PROVIDED FOR ALL SHUT OFF VALVES,CLEAN c. ALL SUPPLY REGISTERS TO HAVE MANUAL VOLUME DAMPERS LOCATED IN DUCT AT OR NEAR CLOSEST r 5 A.!;`,•' b. TILES-ARMSTRONG FISSURED ITEM#705,24 x 24 x 518"WI ANGLED TEGULAR EDGE OUTS,ACCESS DOORS,AND FLOOR DRAINS TO THE ARCHITECT FOR APPROVAL PRIOR TO INSTALLATION. WYE BRANCH, I') r+'�`� a. BAXTER AND FLAMING. (503)225-0486 ## � Iss c " C. ACCESSORIES-MANUFACTURERS'STANDARD €2. PLUMBING CONTRACTOR TO PROVIDE AND INSTALL(1)MASTER SHUT OFF VALVE FOR EACH SET OF d. CLEAN OR REPLACE ALL SUPPLY AND RETURN AIR GRILLS AND THEIR HOUSINGS AT PROJECT () b. D&0 DOOR (503)205-5533 RESTROOMS. LOCATE VALVE BEHIND HANDICAP WATER CLOSET IN MEN'S TOILET ROOM. COMPLETION.{consider deleting thts here in favor of having a tower paid sub do it in DIV 1) c. BENSON INDUSTRIES (503)907-2200 6, ALL TiLE CUTS SHALL BE DONE WITH RAZOR SHARP KNIVES, CUTIfRiM TILE EDGE TO CREATE TEGULAR EDGE CONDITION SO THAT CEILING TILES LAY FLAT. 3. ALL DOMESTIC WATER PIPING TO BE TYPE L COPPER-NO EXCEPTIONS, ALL EXPOSED PIPING TO BE 20.THERMOSTAT: ALL EXISTING MERCURY TYPE THERMOSTATS TO BE REPLACED. NEW THERMOSTATS TO BE d. GRANT SUPPLY (360)887-0647 7. AT CEILINGS OVER 144 SF PROVIDE HORIZONTAL RESTRAINT WiRE OR RIGiD BRACING. INSULATED. HONEYWELL COMMERCIAL GRADE VISiONPRO 8000 TOUCH SCREEN MODEL TB822OU1003 WHERE POSSIBLE. 4. WATER HEATER(ELECTRIC 30 GAL AND LARGER 277V LESS THAN 30 GAL 12OV. PROVIDE HUB DRAIN AT APPROVED SUBSTITUTE: TOTAL-LINE SIGNATURE COMMERCIAL TRI=RMOSTAT MODEL NO.P3742800 -7 DAY 3. DOOR AND RECITE FRAMES SHALL BE(select appropriate)WESTERN INTEGRATED MATERIALS(WIM},ALPHA 8, INSTALL CEILING GRID WITH TWO EDGES ATTACHED TO ADJACENT WALLS. THE OTHER TWO EDGES SHALL BE N F FF } PROGRAMMABLE WITH L CKOUT FUN TI -AUTO CHANGEOVER ONLY. MOUNT AT ADA H I H MAY ALUMINUM PRODUCTS,INC.(AAP),TIMELY,TIMELY 11,OR APPROVED. SUBMITTAL REQUIRED PRiOR TO LOCATION OR BLOW O " " MACKENZiE 2016 ATTACHED 70 WALL MOLD USING SERC2 CLIPS ALLOWING THOSE TWO SIDES TO FLOAT. 1 REQUIRE CHANGING HEIGHT AT REPLACEMENT LOCATIONS). CONTRACTOR SHALL PROGRAM QC ORDERING MATERIAL.NEW FRAMES TO 8E FACTORY FINISH CUSTOM COLOR. 15, POiNT OF DEMAND WATER HEATER-BOSCH POWER STREAM PRO-MODEL RP2P 277V/30A. ADJUST WATER THERMOSTATS AND BALANCE SYSTEM. ALL RIGHTS RESERVED 9, NOT USED. FLOW SETTING TO PROVIDE A HEATING RANGE OF 105 TO 120 DEGREES, CONTACT MESHER SUPPLY FOR 4. NOT USED. 2t,THERMOSTAT LOCATIONS TO BE REVIEWED BY ARCHITECT PRIOR TO INSTALLATION. THESE DRAWINGS ARE THE PROPERTY 10.PROVIDE RIGID STRUTS TWELVE FEET ON CENTER EACH WAY BEGINNING WITHIN SIX FEET OF PERIMETER AVAILABILITY,(503)236 4148. 5. FIELD VERIFY EXISTING DOOR,FRAME AND HARDWARE FINISH PRIOR TO ORDERING. ALL NEW DOORS, EDGE, INSTALL SWAY BRACING EACH STRUT ALONG FIXED EDGE IN ALL FOUR DIRECTIONS 22.WAREHOUSE NEAT: MACKENZIE AND ARE NOT TO BE USED FRAMES AND HARDWARE TO MATCH EXISTING BUILDING STANDARDS. 6. FLOOR DRAINS SHALL BE INSTALLED IN TOILET ROOMS CONTAINING TWO(2)OR MORE WATER CLOSETS OR 2 OR REPRODUCED IN ANY MANNER, 11.NOT USED. OR MORE WATER CLOSETS AND URINALS IN COMBINATION. THE FLOOR SHALL SLOPE TOWARD THE FLOOR a, ,GAS FIRED UNIT HEATERS USED IN NON-CONDITIONED AREAS SHALL COMPLY WITH CURRENT STATE WITHOUT PRIOR WRITTEN PERMISSION 6. ALL INTERIOR DOORS SHALL BE SOLID CORE WOOD UNLESS NOTED OTHERWISE. 12.TUNE UP GRID SYSTEM TO WITHIN PLUS OR MINUS 0,5 INCHES OF LEVEL. I DRAIN. ENERGY CODE REQU€REMENTS, PROVIDE ADJUSTABLE T-STAT FOR EACH UNIT. 7. DOOR HARDWARE SHALL BE SCHLAGE AL SATURN OR D RHODES SERIES U.N.O. ., 17. FLOOR DRAINS TO BE INSTALLED WITH PRIMER VALVE WITH ISOLATION VALVE. NO ATMOSPHERIC PRIMERS. 23.EXHAUST FANS: S. ALL DOOR HARDWARE SHALL 8E INSTALLED WITH A 5"BACKBIT. 09 65 19 RESILIENT FLOORING VINYL COMPOSITION TILE 1 DRAiNS TO BE PREMED FROM TOILET FIXTURES UNLESS OTHERWISE APPROVED BY PACTRUST. PROVIDE A REVISIONS. i. FINISH FLOORING TO EXTEND UNDER CASEWORK... I MIN,12"x 12"ACCESS DOOR. a. CEILING MOUNTED EXHAUST FANS SHALL HAVE A MINIMUM PERFORMANCE TO MEET THE CURRENT 9. DOOR FINISH SUBMITTAL:CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR DOOR FRAMES,DOOR i CODE REQUIREMENTS INCLUDING INTEGRAL BACKDRAFT DAMPER AND VENTING TO THE EXTERIOR. o HARDWARE AND DOORS AS WELL AS A CONTROL SAMPLE OF THE FINISHED DOOR SKIN W1 STAIN AND FINISH 2. INSTALL TILES IN QUARTER TURN PATTERN, 1 PLUMBING-RESTROOM FIXTURES(MULTI OCCUPANCY) COOK GEMINI SERIES 100 OR EQUAL:80 CFM WITH A SONE RATING OF 1.6 OR LESS,100 CFM WITH A vt REViSI0tt8tEYLSiON DELTA APPLIED(IF NEW DOORS ARE BEING PROVIDED). BEFORE FINISHING OF DOORS IS COMMENCED ARCHITECT 09 91 23 PAINTING '1. NOT USED. SONE RATING OF.9 OR LESS.200 CFM WITH A SONE RATING OF 1.6 OR LESS. W W THIS CLOSING DATE SHALL APPROVE CONTROL SAMPLE. FINISHED PRODUCT IS SUBJECT TO REJECTION BY ARCHITECT IF THIS cc d PROCESS IS NOT FULLY ADHERED TO AND FIELD PRODUCT DOES NOT MATCH THE APPROVED CONTROL INTERIOR: i 2. COUNTERTOP LAVATORY KOHLER K=2196 4 OR AMERICAN STANDARD RONDALYN ts. SINGLE FIXTURE RESTROOMS,JANITOR'S CLOSETS OR SINGLE SHOWER ROOMS TO HAVE CEILING MOUNTED EXHAUST FANS,WIRED PER DIVISION 16 AND SWITCHED WITH THE LIGHTS. SAMPLE. i. WALLS; 3, LAVATORY FAUCET-DELTA 501 DST c. MULTIPLE FIXTURE RESTROOMS.COMBINATION RESTROOM&SHOWER,AND LOCKER ROOMS TO HAVE I i 11 10.ALL INTERIOR GLAZING SHALL BE TEMPERED. a. PRIME NEW DRYWALL WITH MILLER'S HIGH-BUILD"SUPER SEAL"PRIMER. 4, TOILET W/FLUSHOMETER-AMERICAN STANDARD AS 2234.015 AT NON ACCESSIBLE STALLS AND 2305.100 AT ROOFTOP MOUNTED EXHAUST FAN,FACTORY CURB AND BACKDRAFT DAMPER,WIRED PER DIVISION 16, - 11.NOT USED, I ACCESSIBLE LOCATIONS. FLUSHOMETER SLOAN FLUSH VALVE 111 OR TANK TYPE TOTO CST744SL AS CONTROLS AS REQUIRED BY DESIGN,COOK ACE-D SERIES OR EQUAL. b. NEW AND EXISTING DRYWALL TO BE FINISHED TO ACHIEVE UNIFORM COVERAGE WITH MILLER'S 6200 OR I INDICATED ON PLAN. ! .i 12.PATCH AND REPAIR ALL HOLES OR DAMAGE TO EXISTING STOREFRONT WINDOWS AND DOORS.TOUCH UP 4480 WITH A TIGHT ROLLER STIPPLE FINISH, RESTROOM FINISHES TO BE MiLLER'S SIG LATEX ENAMEL. d. SPECIALTY ROOMS REQUIRING EXHAUST SHALL MEET THE ABOVE MINIMUM REQUIREMENTS• } FINISH FOR AS NEW LOOK. 2, DOORS AND FRAMES: 15. TOILET SEAT: BEMIS 1955SSC OR OLSON(TE 10SSCT INDIVIDUAL ROOMS WITH AN EXHAUST REQUIREMENT GREATER THAN 250 CFM,SHALL HAVE A 13.GLAZED OVERHEAD DOORS;WAYNE DALTON K-AL,CLEAR SATIN ANODIZED ALUMINUM 6063-T6;HIGH-LIFT 16, AT BACK TO BACK TANK TYPE TOILET INSTALLATIONS US 3"VENT THROUGH ROOF ROOFTOP MOUNTED FAN: . a. NEW HOLLOW METAL-PRIME,SAND,AND FiNISH WITH TWO COATS OF SEMI-GLOSS OIL. 1 OPERATING STYLE(MATCH EXISTING)WITH TRACK AND HARDWARE OF HOT-DIP GALVANIZED STEEL. 17. URINAL-TOTO UT447,AMERICAN STANDARD WA$HBROOK 6501,010,OR KOHLER K-5016-ET W/FLUSH VALVE 24,HVAC TESTING. OPERATION;PULL ROPE FOR DOORS TO 10'TALL,CHAIN HOIST FOR TALLER DOORS.GLAZING/PANELS TO b. EXISTING HOLLOW METAL-SAND,FILL IMPERFECTIONS WITH RONDO,SAND AND PRIME PATCHES WiTH SLOAN 188-1 a. CONTROL SYSTEMS SHALL BE TESTED TO ENSURE THAT CONTROL DEVICES,COMPONENTS, MATCH EXISTING, ALKYD PRIMER,AND FINISH WITH SEMI-GLOSS OIL ENAMEL. 18, NOT USED. EQUIPMENT AND SYSTEMS ARE CALIBRATED,ADJUSTED AND OPERATE IN ACCORDANCE WITH 09 00 00 FINISHES C. WOOD(painted)-PRIME WITH ALKYD OIL UNDER-COATER,SAND,FiLL ALL FASTENING HOLES WITH 1 APPROVED PLANS AND SPECIFICATIONS. { { PAINTER'S PUTTY,CAULK ALL CRACKS IN CASINGS AND BETWEEN JAMBS AND WALLS USING DAP LATEX 9. NOT USED. GENERAL CAULK,AND FINISH WITH SATIN OIL ENAMEL. b, SEQUENCES OF OPERATION SHALL BE FUNCTIONALLY TESTED TO ENSURE THEY OPERATE IN 1. CLEAN,SEAL AND WAX All RESILIENT FLOORS PER MANUFACTURERS SPECIFICATIONS. 10.PROVIDE ONE FLOOR DRAIN IN EACH RESTROOM LOCATED UNDER TOILET PARTITION, ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. d, WOOD(stained)-STAiN,SEAL AS REQUIRED,AND VARNISH WITH SATIN VARNISH. 111.SEALANT AT PLUMBING FIXTURES: C. A COMPLETE COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND 2. SUBMIT SAMPLES OR DRAW DOWNS FOR THE FOLLOWING: 3. CEILINGS: FILED WITH PACTRUST, a. FLOOR COVERINGS,BASE;AND TRANSITION STRIPS 1 a. ALL SEALANT SHALL MATCH GROUT COLOR AT TELE SURFACES. SHEET TITLE; a. NOT USED. ! b. SUBMIT SEALANT COLOR PRIOR TO INSTALLATION FOR ARCHITECT APPROVAL FOR ALL OTHER 25.PROJECT CLOSE OUT DOCUMENTS REQUIRED: PROJECT b. PLASTIC LAMINATES b. NEW GYP BOARD I PLASTER -PRIME WITH SUPER SEAL AND FINISH TO ACHIEVE UNIFORM COVERAGE I APPLICATIONS. a. AutoCAD FILE SHOWING AS-BUILT INFORMATION. SPECIFICATIONS•�• C. ALL NATURAL WOOD(INCLUDING DOORS AND CASEWORK} WITH MILLER'S 6200 OR 4480. =PLUMBING-BREAK ROOM FIXTURES b. ELECTRONIC PDF FILE OF THE AutoCAD FILE ABOVE. SPECIFICA 1 #ONS d. PAINT 4. GENERAL NOTES: 1 1, NOT USED. c. HARD COPY OF AutoCAD FILE ABOVE. e, TELE,GROUT AND SCHLUTER TRIMS a, KEEP ALL HARDWARE,HINGES,AND DOOR KNOBS CLEAN OF ALL PAINT SPLATTERS,DRIPS,OR ROLLER 2. BREAK ROOM SINK ELKAY GECR2521 d. OPERATIONS MANUALS FOR ALL EQUIPMENT,INCLUDING T-STATS. f. TOILET PARTITIONS SPRAY. b. ALL SURFACES TO BE SANDED BETWEEN COATS,PRIOR TO INSTALLATION OF NEXT COAT. 11 KITCHEN FAUCET DELTA 100-DST e. COLORED ZONE MAP WITH THERMOSTAT LOCATIONS INDICATED. . g, HARDWARE 4. INSTANT HOT WATER DISPENSER IN-SINK-ERATOR MODEL#H770-SS 26 00 00 ELECTRICAL: DESIGN I BUILD ' 3. FINISH FLOORING 70 EXTEND UNDER ALL NEW CASEWORK. C. DURING PROGRESS OF WORK,KEEP JOB SITE CLEAN OF ALL PAINT MATERIALS,RUBBISH,CANS,AND RAGS AT THE END OF EACH DAY. 15. 114"COPPER WATER LINE W/SHUT OFF VALVE FOR COFFEE MAKER AND REFRIGERATOR,SEPARATE LINES IF GENERAL . . 4. PROVIDE A TRANSITION STRIP WHERE EVER TWO DIFFERENT FLOOR MATERIALS MEET { REQUIRED d, UPON COMPLETION OF WORK,CLEAN ANY PAINT SPLATTER BY USING PROPER METHODS OF WASHING I 1. ALL ELECTRICAL FEEDS TO OUTLETS,SWITCHES,ETC,MUST BE VERTICAL DROPS FROM ABOVE EXCEPT FOR 5. PROVIDE SCHLUTER METAL TRIM AT ALL EXPOSED EDGES OF TILE(EXCEPT AT BULLNOSED EDGE)OF TILE AND SCRAPING,USING CARE NOT TO SCRATCH OR DAMAGE FINISHED SURFACES. PROJECT CLOSE OUT DOCUMENTS REQUIRED: HORIZONTAL RUNS UNDER WINDOWS AND RECEPTACLES ON THE SAME STUD. (CERAMIC,QUARRY OR PORCELAIN) e, PROTECT WORK OF OTHER TRADES. 1, PROVIDE AS-BUILT INFORMATION TO ARCHITECT AT PROJECT COMPLETION.INCLUDE THE FOLLOWING: 2, ALL ELECTRICAL FEEDS TO OUTLETS AND DATA BELOW WINDOW SILLS TO BE ROUTED THROUGH BUILDING 5, PROVIDE"WET PAiNT"SiGNS AS REQUIRED TO PROTECT NEWLY PAINTED FINISHES, I a. DIMENSIONS (HORIZONTAL AND VERTICAL)OF BUIRED PLUMBING LINES INSTALLED OR DISCOVERED SHELL WALLS. DO NOT FEED FROM PERPENDICULAR INTERIOR PARTITIONS. BY THIS CONSTRUCTION. I 3. PROVIDE LABELS AT EACH ELECTRICAL RECEPTACLE IDENTIFYING CORRESPONDING PANEL AND BREAKER. DRAWN BY: ALC j b. LOCATION OF SHUT OFF VALVES 3. PROVIDE TYPEWRITTEN UPDATED SCHEDULE AT PANEL TO IDENTIFY CIRCUIT BREAKERS. 23 00 00 HVAC: DESIGN/BUILD 4. VERIFY ELECTRICAL METER AND TAG METER WITH THE TENANTS ADDRESS OR SUITE NUMBER. METER CHECKED BY: HRT, AJS 1GAS METER i IDENTIFICATION NUMBER AND TENANT ADDRESS INFORMATION SHALL BE GIVEN TO PACTRUST PRiOR TO I TENANTS MOVE-IN. i 1, CONTRACTOR TO VERIFY GAS METER AND TAG METER WITH THE TENANTS ADDRESSOR SUITE NUMBER. S. ELECTRICAL CONTRACTOR TO PROVIDE EMERGENCY LIGHTING IN EXIT PATH SHOWN ON PLAN EQUAL TO SHEET' METER IDENTIFICATION NUMBER AND TENANT ADDRESS INFORMATION SHALL BE GIVEN TO PACTRUST PRIOR 1-FOOT CANDLE. . TO TENANTS MOVE-IN. . . : # a - I : I 5 I I . . I . . . T142 . I . I . 1 , I JOB N0. � C�Z �. . t - a 1•_ » i aEXIT ,d _ - • a , 13 it 0„ w 4a IN. O► CaM F_[ N1SH SCHEDIlhE DC +ORHED► tJL. E Q - Architecture Interiors co � 10 703~ 10 FLOOR BASE N. WALL E. WALL S. WALL W. WALL CEILING OFFICE OFFICE i ROOM , , , CEILING DOOR DOOR DOOR FRAME HOWR Planning # f ! I ? ROOM NAME MAT'L MAT L MAT L MAT'L MAT'L MAT'L FINISH DOOR DETAILS RATING COMMENTS 9 Engineering NO HT. OPENING SIZE THK TYPE MAT'L FINISH MAT'L FINISH GROUP ^� -�w 1 C PT TVP.E-`�- �`i---� `-I FINISH FINISH FINISH FINISH FINISH FINISH MAT L COMMENTS 101A PR 3,---0„xS,--0»f EXISTING DOOR i L. �. __ ._... 123A f f # 7 € ( -_ _ _J 101 RECEPTION SG RB-2 GB P-1 __ GB P-1 G 10'-0" SAT » , » / 125A ! __.. € r r 102A 3 -Q x8-0 t - G G G -- -- 1 A8.2 H-2 --- -- BREAK _ t� T f ( # # ( t 102 CONFERENCE CPT RB-1 GB/P-? GB/P-1 GB/P-1 GB/P-1 10,-0" SAT 102$ 3'-0"x8'-0"t - G G G -- -- 1/A8.2 H-2 -- ;. ( ( # ( # 103 OPEN OFFICE CPT/SC RB-1,2 , , » � 122 �� PC r - -_ 2 P-1 P-1 GBfP-i GBjP--? EXIST QTS 103A 3 --0 x9 -0 t EXISTING DOOR s o j OPEN ( # '- ~--� -` 104 OFFICE CPT RB-1 GB P-1 GB P-1 GB P-1 G$ P--1 , , , » " _ __ Portland,OR . OFFICE r 1 r r 10-- SAT 104A 3-0 x8 -0 t 1 FL SC S AWF CAA 1q/A8:? H-1 124A OFFICE OFFICE f- -� .._ ,� -103 _ __ _.� -#� _ #__ .. 145 OFFICE CPT RB-1- GBjP--i GB/P-1 GB/P-1 G8 P-1 101-01, SAT 145A 3'-0"x8'-q"f 1 " FL $C S AWF CAA 10/A8.1 H-1 _ ---- 5Q3.224.956 + . =- r• ` .I ! �� � € 106 OFFICE CPT RB-1 G$ P 1 G8 P 1 GBP ? GBP 13'-0"x8'-O"± 3 „ __ __ Vancouver.W?► ' 124 ?26 1- -� # ( I ___� # _ J / / _ / -- / -- ? - SAT 106A 1 FL SC S AWF CAA 10/A8.1 H-1 r._ _ RB-? GB P-i GB P-1 GB P-i GB/P ►_ » I » » s „ 360.695.7879 �I L t,.! f # s 10 16►_0„ 15,_8,► '^ € ( ( # f 107 OFFICE CPT r r / r SAT 107A 3 -0 x8 �-0 t 1 FL SC S AWF CAA 101A8.1 H-1 _.. _... ! .- , ( # ( , # ( 108 HALL SC RB-2 --- GB/P-? -- GB/P-? EXIT QTS 109A 3'-0"x8'-4"t 1 " FL SC S AWF CAA 8/A8.1 H-i __ __ Seattle,WA E OFFICE CPT RB-1 GB/P-1 GB/P-1 GB/P-1 GB/P-i '_ " S T ?10A 3'-0"x8'-0"f 1 " FL SC S AWF CAA 8/A8.1 H-i 206.749.999: �' 1 ( ( . #. f ( { CP 109 r -�-•--«--CPT -- -- i F 5.,,_` ,r HALL PC L , Lr .� J" ??0 OFFICE CPT RB-1 GB/P-? GB/P-1 GB/P-1 GB/P-1., ,_ » , I, » » A5 f o _.. ,, __. - -,-.•-. ,, ,� #, AT IIIA 3 -0 x8 -0 t 1 Y FL SC S AWF CAA 8/A8.1 H-i -- www.mcknae.con� » 127A » , 6 ?0 -0 10 -a 10 --0 - - -- - '; 0-1 - 111 OFFICE CPT RB-1 GB/P-1 GB/P-1 GB/P-1 GB/P-1 1 '..p" SAT 1?3A 3'-0"x8'-0"f 1�" FG/R SC S AWF CAA 10/A8.? H-1 __ __ - SC SC 112 OPEN OFFICE CPT/SC RB-1,2 GB/P-? P-1 GB/P-1 GB/P-1 EXIST OTS 114A 3'-O"x8'-4"f 1Y4" FG SC S AWF CAA 9/A8.1 H-1 -- -- M A K E N Z 1 E M. 4 - ,,I 107A OOs 105A 104A ( SC 113 OFFICE CPT: RB-1 GB P-1 P-1 P-1 GB/P-1 10'-0" SAT 115A 3'-0"x8'-0"t 1%-F'- FL/R SC S AWF CAA 101A8.1 H-1 r • --- 114 OFFICE CPT RB-1 GB/P-i GB/P-i P-1 P-1 1 " SAT , » , » 3 » -- -'" OBS4QN DRIVEN 1 CLIENT fOCU56D = - 117A 3 -O x8 -0 t 1 FL SC S AWF CAA 9 A8.1 H-1 A5.1 r . L__._,-.. .� CP SC fF---�f -1 1 MEN 121A - �. PT 10 10 C PT 10 10 C `_. �� r!l�-I 115 OFFICE CPT RB-1 GB/P-1 GB/P-? GB/P-1 P-1 '-- SAT 128A 3'-q"x8'-0"f I%" FL SC S AWF CAA 9/A8.1 H-1 -- -- 121 . 102~ �- 116 WORK COPY VCT RB-2 GBjP-1 GB P-1 GBfP-1 P-1 SAT 6 '-- » 119A 3'-0"x9'-O"f 1 f" SF G G AWF CAA 9jA8.1 H-4 --_ 2 -. _ - 1i7 SERVER VCT RB-2 GBjP-? GBfP-1 GB/P-1 P-1 '-. A7 120A 3'--0"x8'-0"f 1 " FL SC S AWF CAA 9jA8.1 N-3 OFFICE OFFICE OFFICE OFFICE I ? �( ( f `il I 118 OFFICE VCT RB-2 GB P-1 GB P-1 GB P-1 GB P-1 ' » , » , » » ,� { r 11 / / r / AT 121A 3 -0 x8-0 t 1 FL SC S AWF CAA 91A8.1 H-3 � o a CT ' 107 ► 106 105 104 �.� ,�,cr 11 ' • "3 ( ( # " r r EXIST OTS - 119 HALL SC R8-2 -- GB B/P --- GB P-i. » , » » 122A 8 -0 x10-0 f 1� OH ---- -_ AWF CAA 2/A8.3 --- -- 3 • ' � - - � TYP.! - 120 WOMEN PT-1 PT-2 PT 3/GB - GB/P-1 GB/P-1 AQjGBjF-1 �_ " g » , » „ i 123A 3 -Q x8 -0 t -- o o ti HALL r RE EPTION 121 MEN PT-1 PT-2 GB/P-1 GB/P-1 PT-3/(B/P-1 A01GB/P-1 GB 124A 3 -0 x8 -0 t ? E!ZR SG S AWF CAA 10 A8.1 H--1 �> r s 48 GtS FEI?EN 10 122 BREAK SC RB-2 GB/P--1 GB/P-1 GB/P-1 P-1 EXIST OT 125A 3'-O"x8'-0"t 1 FL/R SC S AWF. CAA 104A8.1 H . 1 --- -- 120A ; ` EXIT - 1p - 4 1 1o1A 123 OFFICE CPT RB-1 GB/P--I GB/P-1 GB/P-1 GB/P-1 10'-0" SA 126A 3'-0"x8'-0"t i 4" FL R SG S AWF CAA 101A8.1 ---- I 1 ( ff A8.2 124 OFFICE CPT RB-1 GB/P-1 GB/P-1 GB/P-1 GB/P-1 ,_ I' 5AT WOMEN 125 OFFICE CPT RB-1 GB P-1 GB P-1 GB P-? GB P-1 ,_ y 120 r Iti f f r r / / SA7 HARDWARE GROUPS: ADQhF�VIATIQNS; S ` To :.. .__ --- -»-. .M-..... ..» . I_ _ ,� a`^ 126 OFFICE GPT RB-1 GB/P-1 GB/P--1 GB/P-1 GB/P-1 '- " AT H-1: PASSAGE AWF ALPHA WIM FRAMES Pri Alm / ' f 127A HALL SC RB-2 GB/P--1 --- GB/P-1 -- 1t7A t8A � 3 OFFICE OFFICE aI 3 OFFICE o _� �� ' � f ( f 9 ►�'. -. -.., LATCHSET F75 GRADE 1 VC -Sc 111 110 109 11 � � �•-�.-.•--- f CAA CLEAR ANODIZED ALUMINUM --, FINISH SCHEDULE NOTES: A�BRYL9TiQ� � BUTTS, SEAL, STOPS EXIST EXISTING Q SERVER OFFICE HALL TYP. [ ( A. ALL INTERIOR FINISHES BUILDING STANDARD, COLORS AQ AQUATOUCH PAINT H-2; PUSH/PULL FF FACTORY FINISH 117 118 i 19 8 CP PT 8 CPT 8 12 CPT SC .. _i ( TO BE COORDINATED WITH OWNER. CPT CARPET PIVOTS, NO LOCK FG FULL GLAZED VISION PANEL ,r toga _ --- 1 B. PATCH AND REPAIR ALL EXISTING WALLS WHERE EXIST . EXISTING H-3: TOILET ROOM FL FLUSH FL/R FLUSH WITH ADJACENT RELITE EQ. EQ. 111a 1toA tosA C AFFECTED BY NEW. WORK. PAINT NEW AND EXISTING GB GYPSUM BOARD. LATCHSET / WALLS. OTS OPEN TO STRUCTURE G GLASS EQ SC SC EQ. SC 4 ( BUTTS, STOP, CLOSER, OH OVERHANG DOOR ow _ __t _._ �,. ___ C. PROVIDE NEW PAINT, RUBBER BASE, AND FLOOR FINISH P PAINT KICK PLATE S STAIN WORK COPY - t --1-- -1 F--1-- -t r-7- -7 THROUGHOUT. PT PORCELAIN TILE 116 � ,_... __.. � ....� �. .�T._ _.} C-....�.. .. .-_ t � ! ._.._� .� � SC SOLID GORE WOOD 1� H-4. EXTERIOR ° f f f # r- ,� w __.. . _ _._ __ I 1 ( f f - C T RB RUBBER BASE M 6 CP �- CPT _� f I LOCKSET GRADE I *- A5.1 # # l f I ! f 1 ( i ( f f ! ( i SC SEALED CONCRETE BUTTS SEAL STOP CLOSER SF STOREFRONT Project 5 f # _ OPEN;~ _'' I i ' SAT SUSPENDED ACOUSTIC TILE INSPIRED.RESULTS �.,.__1 � L__.._ _r # �_ �_.� . MATCH EXITING STOREFRONT OFFICE { VCT VINYL COMPQSITIQN TILE HARDWARE SUITE �..#.._ TENANT IIVIPORC�1lEMEN TM __ _ DOOR SCHEDULE COMMENTS: DOOR SCHEDULE NOTES: t15A I-- - -- f r� f - f �- --- -- -_ r -- f - 9. EXISTING EXTERIOR DOOR A. ALL DOORS/CLOSURES TO BE CHECKED, ADJUSTED, CP ,� ( # f # 7 f { 2. NEW EXTERIOR STORE FRONT AND/OR REPLACED TO BE IN COMPLIANCE WITH ADA 'd OFFICE BUL�I�IQ 4 I _ : f # # # # f `- `-- ---1 DOOR TO MATCH EXISTING B. ALL DOORS, FRAMES AND HARDWARE TO MATCH 115 10 - , 3 <._ _�. � � ��_1 -. L.. J.- J L.._L_, �� J STOREFRONT TENANT BUILDING STANDARDS. PCffn-AND OREODN 20'-0"f MIN.. 1 # 3. NEW OVERHEAD DOOR ► 113A 10 7 DOOR FINISHES S DOOR: PACIFIC ARCHITECTURAL WOOD PRODUCTS, QUARTER SLICE, AFRICAN 'q i MAHOGANY, COLOR PAC AMBER AOA 0. M 1£ OFFICE OFFICE HARDWARE: 605 POLISHED BRASS OR 613 OIL RUBBED BRONZE OR POLISHED CHROME 114 113 _ OR 626 SATIN CHROMEMEMIN a 2 ; FRAMES: PAC RED OR SMOKE WHITE OR BROWN TONE OR CLEAR ANODIZED vqp s 25'-O 22,-7»t MACKEN2IE 2016 Q ALL RIGHTS RESERVED THESE DRAWINGS ARE THE PROPERTY MACKENZIE AND ARE NOT TO BE USED OR REPRODUCED IN ANY MANNER, WITHOUT PRIOR WRITTEN PERMISSION f r REVISIONS: PARTIAL. FiRt"mr FLOOR PLAN z z ig< REVISIONS2EVISION DELTA �AV) 1/8"-1'-Q" _ ( iaw THIS -� . CLOSING DATE ! ma SKEET 7- GENERAL t NNOTES KEYNOTES LEGEND GE ERAL A. DIMENSIONS REFLECT FACE OF FINISH TO FACE OF FINISH, UNLESS NOTED OTHERWISE, 1. ALIGN NEW WALL WITH EXISTING WALL: EXISTING WALL TO REMAIN B. WALL 'THICKNESS ARE NOMINAL, UNLESS NOTED OTHERWISE. 2. CENTER NEW WALL WITH EXISTING MULLION, SEE DETAIL 7/A8.1. MODIFY EXISTING NEW WALL TO 12'--0" AFF, SEE 6/A8.1 C. ALL INTERIOR WALLS TO GO TO UNDERSIDE OF GRID UNLESS NOTED OTHERWISE. WINDOW COVERINGS AS REQUIRED. D. ALL INTERIOR DOORS TO BE SOLID CORE FLUSH WOOD DOORS TO MATCH BUILDING 3. ALIGN NEW WALL WITH EDGE OF EXISTING COLUMN, NEW WALL TO UNDERSIDE OF GRID. SEE 4/A$.i SHEET TITLE: 4. ALIGN NEW WALLS. PARTIAL FIRST STANDARD UNLESS NOTED OTHERWISE. NEW DEMISING WALL TO STRUCTURE, -SEE 5jA8.1' 5. NEW P-LAM UPPER AND LOWER CABINL I RY. R PLAN, E. OUTLETS INDICATED ARE EXISTING UNLESS NOTED OTHERWISE. SITE VERIFICATION 6. NEW UPPER AND LOWER CABINTERY, SINK, FLOODSTOPPER, DISHWASHER, MICROWAVE T( NEW OUTLET AND VOICE/DATA ROUGH IN LOCATI6N HAS NOT BEEN PERFORMED AND PLAN, ELECTRICAL AND CEILING INFORMATION HAS NOT SHELF AND PLUMBING. SCHEDULES AND BEEN UPDATED (OBSERVATION IS LIMITED TO VISIBLE/ACCESSIBLE AREAS). CONTRACTOR 7. WORK STATION BY OTHERS. COORDINATE!POWER REQUIREMENTS WITH TENANT. J. NEW LIGHT SWITCH WITH OCCUPANCY SENSOR NOTES TO FIELD VERIFY AND CONFIRM ADDITIONAL REQUIREMENTS WITH TENANT. 8. NEW 5'-O"t WIDE TEMPERED RELITE AT W-O" AFF. CENTERED ON WALL BETWEEN F. FURNITURE IS SHOWN FOR SCHEMATIC PURPOSES ONLY. TENANT OR TENANT CORNER AND DOOR. TO MATCH TENANT $UILDING STANDARD, SEE DETAIL 8/A8.1. 1 KEY NOTE FOR REFERENCE 9. NEW (6) EQUAL BUTT GLAZED PANELS FdR A TOTAL OF APPROXIMATELY 23'-10", SEE VENDOR TO CONFIRM BUILT CONDITIONS FOR SPATIAL REQUIREMENTS AND FINAL { LAYOUTS. DETAIL 1/A8.2 G. LOWER VOC PAINT SYSTEMS TO BE UTILIZED, TO INCLUDE PRIMERS AS WELL AS 10. NEW 3'-0"t RELITE AT 4" AFF. NEW BLINDS TO MATCH EXISTING, IF APPLICABLE, SEE x INTERIOR ELEVATION FOR REFERENCE DETAIL 14/A8.1. � NUM- FINISH PRODUCTS. 11. FURNITURE AND EQUIPMENT NIC. TYPICAL WHERE HALF TONED. TENANT OR 'TENANT DRAWN BY:ALC* H. ALL DIMENSIONS SHOWN AS PLUS/MINUS (f) ARE FOR GENERAL LAYOUT AND VENDOR TO CONFIRM BUILT. CONDITIONS �"flR SPATIAL REQUIREMENTS AND. FINAL 1oaA DOOR NUMBER SYMBOL REFERENCE ONLY. LAYOUT- f CHECKED BY. MRT, AJS 12. PROVIDE POWER AND BLOCKING Al WORK FOR TENANT PROVIDED TV. COORDINATE FINAL EXIT REQUIRED EXIT LOCATION WITH TENANT. ( SHEET: 13. NEW 10'X1O' CONCRETE PATIO WITH CONNECTOR WALK TO DOOR 119A WALKWAY. 14, MODIFY EXISTING EXTERIOR GLAZING TO ACCOMMODATE NEW 8'-0"W X 10'-0"H � NEW FIRE EXTINGUISHER LOCATION • OVERHEAD DOOR, 3 -A2 # ■ JOB NO. 2160267,03 PF- WAIT P ": OA/9q/1 F 15#-7pt } 18 -10" 2r-7n 2r-6"4 15" 3 - it193 7 VC 3 5 -0" '� 0 14 •w � Architecture Interiors 1 Planning Engineering 0) 13 18 9 _ 8 a 6 4 5'--0 2'-7„ 2'--6" 5'_0,r TP 1, TYP. 10 CEILING i x l 1 _ ,_ ' --j ;.. .= 7_. 1_�.. ` Portland,OR _. i 5 f I4_ i .J _.._.f i //// D17 503.224.9560 Vancouver,WA 2 1 _. _ _.. _ 1_ _ 14 360.695.7879 O 1 O O � � I � �' 1 ; # � I i g Seattle,WX► 1 4 �` • f __ 8 9 � 6 � I ! ' I �� ..._.._.. � 206J49.999�� 13 , ca 18 www.mcknze.com 1 °' 3 5 - 4'-0" x { 5 P MACKENZI E' - 7 D _HV _I i F_T_ , - .� _ � Dfi516N DRIVEN 1 CLIENT FQCURfiO { 2 1g A5.1 B `� '-6 4'--10" 20-7C18) 15 16 TYP. C - z 0 X, z _ ¢ A B C D a -- w 0 1 ' o ENLARGED TI��T ROS PLAN z TOL�ET ROOM ELEVATIONS -- WOMEN ,... 1 1/4"=1'--O" WOMEN 120 3 1 4"=1f-0,. > - A5. z ASJ / W 1 w �.R kit. OUST, i NOTE: ALL ACCESSORIES TO BE ADA AND MATCH PACTRUST STANDARDS EE T1. � S 2. 1 -0 3 - 3p-O" /� 1Y2" TP-1, TYP. 0 5'-0" 2'-6" 2'-7" 5'-0" CEILING -r �I �l rI ¢ �- Project INSPIRED RESULTS f 17 4 SUITE-100 14 r # T 6 1 3 TYPICAL ACCESSIBLE STALL GRAB BAR SECTION WATER CLOSET ADA URINAL TENANT IMPORUYEMEN 19 BUILDING 4 -1 5350 SW SEGUQIA P'KW, � Q o OREGON - -- M Z a > O M X }, - '-3' '-3 2'-7" 4'-1 C!" '-6 13 SOAP PAPER TOWEL. SAN.NAP. PAPER TOWEL! RECESSED SEAT COVER TOIL.PAPERI GRAB BAR MIRROR y 1 TYP, � DISPENSER DISPENSER DISPENSER DISPENSER/ TOWEL DISPENSER SEAT COV.DISP./ z DISPENSER SAN.NAP. A $ C DISPOSAL r ADAM J 0' , LJ o o fMAIND.CRCG,3N K�3WALL ELEVATIONS ? 4 TOILET ACCESSORIES ANCA FIXTURES0 6635 - "=If-on > 1 A5. ) OMEN 121 F 1/4 w �AW) MOUNTING HEIGHTS AND DIMENSIONS 1/4"=1'-�0" o ° L. L. © MACKENZIE 2016 SCHEDULE OF INTERIOR FINISHES GENERA NOTES ALL RIGHTS RESERVED - THESE DRAWINGS ARE THE PROPERTY MACKENZIE AND ARE NOT TO.BE USED GPT--1: MOHAWK GROUP, CROSS KNIT BC375 / 81375 - (COLOR TBD), DIRECT GLUE A. VERIFY AND CONFIRM ALL DIMENSIONS AND CONDITIONS PRIOR TO START OF OR REPRODUCED IN ANY MANNER, I WORK. NOTIFY ARCHITECT/ENGINEER OF ANY DISCREPANCIES PRIOR TO START WITHOUT PRIOR WRITTEN PERMISSION VCT-1: ARMSTRONG FAFFIA, (COLOR TBD), 12"X24"X " OF WORK, ,. B. SEE DETAIL 4/A5.1 FOR ACCESSIBILITY DETAILS & MOUNTING HEIGHTS. REVISIONS: QUARTZ SPLASH I RB-1. FLEXCO, 4 FLAT RUBBER BASE, (COLOR TBD), AT ALL CARPET AREAS. z C. DIMENSIONS REFLECT FACE OF FINISH TO FACE OF FINISH U.N.O. < Iz�vSIONMEVISION DELTA " D. DO NOT SCALE DRAWINGS TO DETERMINE SIZES ON DIMENSIONS. n THIS CLOSING DATE QUARTZ TOP AND SKIRT EDGE RB-2: FLEXCO, 4 FLAT RUBBER BASE, (COLOR TBD), AT ALL HARD SURFACES. SHEET ON PLYWOOD / PT FRAMING E. WALL THICKNESS ARE NOMINAL U.N.O. an P--1: MILLER, 4480 PREMIUM SATIN (COLOR TBD), SATIN LATEX F PROVIDE SOLID BLOCKING / BACKING FOR ALL TOILET ROOM EQUIPMENT p t (GRAB BARS, COUNTERS, ETC.) ` s P-2: MILLER, 4480 PREMIUM SATIN (COLOR TBD), SATIN LATEX (ACCENT COLOR) G. CLEARANCES TO ACCESSIBLE SANITARY FIXTURES ARE MEASURED FROM THE '" ~ LAVATORY SINK- UNDER MOUNT 1 PL-1: FORMICA (COLOR TBD) ALL SURFACES FACE OF FINISH OF MATERIALS. ___. ...... TRAP- WRAP TRAP AND DOMESTIC HW CENTER 6" TILE H. WHERE ITEMS ARE SHOWN IN MULTIPLE PLANS AND/OR ELEVATIONS, ON WALL PL-2: FORMICA (COLOR TBD) COUNTER, B.S AND SELF-EDGE IMPROVEMENTS TO BE MADE AS NOTED ON OTHER PLANS, SUPPLY W/ INSULATION KIT o o - � 1 I. ALIGN FLOOR, BASE AND WALL TILE JOINTS WHERE MODULATION PERMITS. I SS-1: PENIAL QUARTZ (COLOR T80), TOILET ROOM COUNTER, B.S AND SELF-EDGE STRETCH FLOOR JOINTS AS NECESSARY TO MATCH WALL JOINTS TP-1: HADRIAN POWER COATED - (COLOR TBD) PAINTED GYP. BD. WALL BEYOND - KEYNOTES SHEET TITLE; PT--1: CROSSVILLE,' SHADES AV243 FOG UPS 12 X 24 (FLOOR TILE) » ENLARGED TOILET 1. 36 GRAB BAR. ELEC, OUTLET FACE PLATE & BOX - PT-' 2: CROSSVILLE, SHADES AV243 FOG UPS 4 X 24 SINGLE BULLNOSE (WALL. BASE) Z, 42" GRAB BAR. ROOM FLOOR PLAN, MOUNT AS HIGH AS POSSIBLE 3. VERTICAL GRAB BAR. DETAILS, I PT-3 DAL TILE, 0790 MATTE ARCTIC WHITE WALL 4 X 12 (WALL TILE) 4. NEW SINK AND FAUCET, 5. NEW P--LAM VANITY TOP, SEE 5/A5.1,WRAP PIPES TYPICAL. ELEVATIONS AND GROUT: TEC 915 LIGHT SMOKE 1/8" (EPDXY) 6. NEW UNFRAMED MIRROR ABOVE SINK, FULL LENGTH OF COUNTER TO CEILING. NOTES PORC LAIN TILE FLOORIN BASE uy 7. NEW TOILET PARTITION TO 'MATCH EXISTING BUILDING STANDARD. z 8. NEW FLOOR MOUNTED ADA TOILET. FULL 12x24 TILE, ¢ 9. NEW FLOOR MOUNTED STANDARD TOILET. � TYP a 10. NEW ADA URINAL. w 11. NEW TILES AT WALL, PT-2. DRAWN BY:ALC COUNTER SEf.".."TION 6 TOILET` ROOM FINISH PLAN, 12. NOT USED. 13. NEW SURFACE-MOUNTED TOILET PAPER AND SEAT COVER DISPENSER. A�.1 14. NEW SURFACE-MOUNTED OR RECESSED PAPER TOWEL DISPENSER. CHECKED BY: MRT, AJS > w 15. NEW TILE FLOORING, PT-1. 16. NEW 4- TILE SHEET: 1 17. NEW WALL MOUNTED PVANITY LIGHT FIXTURE, L-4, FIXTURE TO MOUNT ON WALL BEHIND MIRROR 1 18. NEW FLOOR DRAIN. SLOPE FLOOR TOWARD FLOOR DRAIN. 19. NEW AQUATCUGH PAINT AT WALL TO 48" AFF. A5ml i - I .5 } JOB N0' 2160267.03 limns 14 VOTES: NOTES: { { A. FINISH ENDS, TYP D. SHIM AS. REQUIRED A. FINISH ENDS, TYP i C. SHIM AS REQUIRED 13" CLR. (1) ADJ, B. CONFIRM REQUIREMENTS AND SIZES E. ALL CABINET FACES AND DOORS, PL--# B. ALL COUNTER TOPS, EDGES AND D.` ALL CABINET FACES AND DOORS, PL-1 j U.N.O. MELAMINE SHELVES FOR ALL EQUIPMENT/APPLIANCES F ALL EXPOSED EDGES AT DOORS- AND SHELVING BACKSPLASHES, PL-2 E. ALL EXPOSED EDGES AT DOORS: AND SHELVING (2) ADJ. MELAMINE SHELVES PRIOR TO CONSTRUCTION OF TO BE P-LAM TO MATCH ADJACENT TO BE P-LAM TO MATCH ADJACENT > AT SIMILAR CABINETRY VERTICAL. SURFACES. VERTICAL SURFACES. � -LAM FACES C. ALL COUNTER TOPS, EDGES AND G. PROVIDE WATERLINE FOR TENANT PROVIDED w P BACKSPLASHES, PL-2 COFFEE MAKER, r 2 M Architecture a Interiors rGRowavE, NIC - Planning a Engineering P-LAM UNDERSIDE AND 6 SHE II INSIDE OPENING LLJ> F 3 4 5 5 N SHELF S A5.2 A5.2 A5.2 IM. w A5.2 SIDE SPLASH WHERE OCCURST LU . CEILING CEILING W ALIGN W/ LOWERS 25" TOP Portland,OR - ; ALIGN W/ LOWERS U.N.O. 503.224.9560 P-LAM COUNTER TOP AND Vancouver,WA € SPLASH WITH SELF EDGE 360.695.7879 Seattle WA I r I 06.749.9993 RF}MMUTOR REFRIGERATOR I I 1 i 1YA T, www mcknze.c©m INSULATE EXPOSED o (1) ADJ MELAMINE II I . I PIPES PER ADA COD „1 w SHELF, NO DRAWER OR j E 1 I 1 cv - E t SHELF AT SINK LOCATION M MC K E N Z E C, E - - - - -- - PROVIDE DISHWASHER - - - lwi.f - _ DESIGN DRIVER i CLIENT FOCUSED , DMWA7F� 1 I 1 .w-._--- P--LAM FACES C4 Cq RUBBER BASE (3) EQ. 2 -p 3t-(?" (3) EQ, (3) EQ. o -, 4'-0" 4' ri ""� CABINETRY ELEVATION CAB N x L TI+aN 3C B_ I ETRY EVA CABINET SErION w �► 0 BREAK 122 1/4"_1._0,, w �1 Jr-. 0 WORK/COPY 116 f 1/4"--1`-0" > A5 TYPICAL 3/4"=1'--p" amt LU ,13" CLR. ,, U% .N.O. 13 CLR. I N. ; . U. Iacs!iO.Rtr1set�ci . 1 (2) ADJ MELAMINE _ (2) ADJ. > I SHELF, TYP LU � � a � MELAMINE SHELF w > 1— W w 1 P--LAM FACES w _ I UPPER CABINETS, DEPTH MAY VARY AS REQ'Dt P--LAM FAGSSEE CASEWORK ELEVATIONS LLA-1 w 25" P.L. TOP U.N.Q. > 25" P.L. TOP w I V-5"-5 MAX SIDE SPLASH WHERE OCCURS SIDE SPLASH WHERE OCCURS Project To FAUCET w I INSPIRED RESULTS CONTROLS SUITE 100 P-LAM COUNTER TOP AND _ �_ P--LAM COUNTER TOP AND TENANT IMPQROVEMEI� - SPLASH WITH SELF EDGE SPLASH WITH SELF EDGE WRAP ALL EXPOSED PIPE NO DRAWER AT SIM CONDITION - ►� � PER CODE _I � 4.. 535(? SW SEt?UM I�C1f11;. 1 ADJ MEL MINE > ( � PORTLAND O N iv P-LAM FACES w SHELF; NO DRAWER OR t SHELF AT SINK LOCATION W W 8 `i Uj P-LAM ctQ „ a t`1 Z RUBBER BASE cel TOE KICK AND RUBBER AAAtsA,. S 2t-p" 3 BASE BEYOND , " 2 0 o r ll 1 I�3RTL.4t� C • �, REG'�PE r4� CABINET SECTION COUNTER SECTION W A5,2 TYPICAL 3/4 =1 -0 AJ.` TYPICAL 3/4 =1 --0 MACKENZIE 2096 ALL RIGHTS RESERVED THESE DRAWINGS ARE THE PROPERTY MACKENZIE AND ARE NOT TO BE USED OR REPRODUCED IN ANY MANNER, WITHOUT PRIOR WRITTEN PERMISSION 3 REVISIONS: i vvs< FMIONSREVISION DELTA a 5� THIS CLOSING DATE I w w SHEET t F i f s . 2I 4 f' k SHEET TITLE: CABINETRY ELEVATIONS AND DETAILS DRAWN BY:ALC CHECKED BY: MRT, AJS SHEET: A5,2 s JOB NO. 2164267.03 W EQ. --- Ilk k i;. Architecture a Interiors 4/-4,/ 4P-4° Planning Engineering TYP. 2 TYP. Portland,OR 503.224.9560 Vancouver,WA OTS -� 10'—O" 0 360.695.7879 - w Seattle,WA 206.749.9993 G'� r°•-"`� '.y, ;.,�•��••�•+:'••�•.•GY!''.; ;.;:,•:,:•4,.' WVif W.t11CICnZe.GQt11 . . .• y'•;••j :• •+ '.:s. .i.%,•.•' m DCYt6N DRIVEN 1 CLIENT FOCUSED `t` -fi'a:•a I ot1•.N• 'r 44•ts �a.i. `si r"•r �r-0» I w :..,t�;j- ,. •...:" :.::" TYP. { Cf MR7 mod 6m LO f-rY =LML a , 1 f ?- 2k OTS "" Pro ject INSPIRED RESULTS '00-0" SUITE 100 TENANT IMPOROVEMEN 4'-5" 6'-0" TYP. TYP. BANG 4 v 5350 SW SEOUOIA PKW POI TL M, OREGON 4 40", SolJA aa MACKENZIE 2016 # ALL RIGHTS RESERVED i REFLECTED CEILING PLAN THESE DRAWINGS ARE THE PROPERTY MACKENZIE AND ARE NOT TO BE USED �A6.1) -OR REPRODUCED IN ANY MANNER, j Jg„ t-0" WITHOUT PRIOR WRITTEN PERMISSION REVISIONS: z c r);• REVISIONFEVISION DELTA ECd THIS CLOSING DATE SHEET GENERAL NOTES KEYNOTES A. SUSPENDED ACOUSTICAL TILE CEILINGS AT VARIOUS HEIGHTS, UNLESS' • 1. PROVIDE SOUND ATTENUATION BATT ABOVE CEILING TILES, 2'-0" ON INSIDE WALL AT NOTED OTHERWISE. ALL NEW CONFERENCE ROOM WALLS. B. FOR SEISMIC BRACING OF SUSPENDED CEILING AND INTERSTITIAL EQUIPMENT 2• OPEN TO STRUCTURE. SEE DETAILS 1/A8.1. C. CENTER ALL DOWN LIGHTS, FIRE SPRINKLERS HEADS, SMOKE DETECTORS AND ALL OTHER CEILING PENETRATIONS IN CENTER OF TILE, UNLESS NOTED OTHERWISE. LEGEND F D. COORDINATE ELECTRICAL REQUIREMENTS WITH TENANT, ALL ELECTRICAL - E DRAWINGS WILL BE BY DEFERRED SUBMITTAL. NEW CEILING GRID . E. HVAC CONTRACTOR TO PROVIDE FULL SHEET of THE FLOOR AFFECTED UPON COMPLETION. CONTRACTOR IS RESPONSIBLE TO PROGRAM THE OVERRIDE HVAC BUTTON NEW 2x2' FLUORESCENT LIGHT FIXTURE, L-1 SHEET TITLE;. E F. LIGHTING LAYOUT IS SHOWN FOR PRELIMINARY DESIGN INTENT ONLY. 0 NEW RECESSED CAN LIGHT FIXTURE, L-2 PARTIAL.REFLECTEC FINAL LIGHTING LAYOUT TO BE PROVIDED BY THE ELECTRICAL. CONTRACTOR AND IS CEILING PLAN AND r DEPENDANT ON OREGON ENERGY CODE ALLOWANCES AND EXISTING BUILDING NEW 1x4 LIGHT FIXTURE, L-3 NOTES INFRASTRUCTURE IN CEILING. NEW VANITY LIGHT FIXTURE, L-4 9 NEW EXIT SIGN BATT INSULATION ON WALL NEW GYPSUM BOARD CEILING r-- € DRAWN BY: ALC LIGHTING SCHEDULE CHECKED BY: MRT, AJS L--1: LITHONIA, 2BLT2 40LHE ADSMT LP835 x SHEET: t L-2; LITHONIA, LDN6 35/90 L06AR 7=o t L--3: FINELITE S16—LED—ID---DCO-4ft--2E—V-8-35—OPEN A61 } L-4 FINELITE S17—LED—ACF—PF--4ft—S-8-35 # l JOB NO. 2160267.03 FLOOR OR ROOF STRUCTURE , POP RIVET RUNNER TO 7 8" WALL ANGLE AT 2 TRACK BLOCKING Wj 1 1/2" FLANGES. / BERC 2 :, ADJACENT WALLS, FASTEN CLOSURE ANGLE WITH #6 8 MAX. CLIP SIZE & GAGE TO MATCH METAL STUD . . u p '-- SCREWS DIRECTLY TO WALL FRAMING OR PROVIDE STRUT CEILING JOISTS. LOCATE IN EVERY LIMITING WALL HEIGHT TABLE STABILIZER BAR BETWEEN ALL MEMBERS AT PERIMETER WH SPACE FOR STUDS 0 16" cc & 3� EACH END OF WALL. WERIOR NON STRUCTURAL COMPS WALLS L/240 0 5psf ADDITIONAL #12 WIRE SUPPORT AT ALL MEMBERS o l DESIGNATION SPACING MAX. WALL HEIGHT WITHIN 8" OF PERIMETER :NOTE. CEILING�J*IST MAX SPANS ' LATERAL BRACING WITH APPROVED VERTICAL 600S137-33 METAL STUD CEILING 362S125-18 24" 13'-5 COMPRESSION STRUT AT 12'-0" OC EA WAY %8 ;JOIST 0 16" cc MAX SPAN 17,-6" " " COUNTERSLOPE HANGERS IF MORE THAN 1:6 OUT OF PLUMB '` ,$ Wj 200U5©-54 U—CHANNEL AT MIDSPAN 3625125-18 16 14--4 Architecture � Interiors `3625125-18 METAL STUD CEILING JOIST 362S162-33 16" 16'-5" Planning Engineering "ATTACHED , I0 16" cc MAX SPAN 7'-9" ( I 362S162-43 16" n WALL .� ` 18 —0 (� ` •Q 13625137-33 METAL STUD CEILING JOIST 600S162--33 16" 24'-6" _0 16" cc MAX SPAN 10'-8" AT WALL �f /07NCELM EDW WH NON STRUCTURAL COMPOSITE WALLS A " Portland,OR 1 °/ 'x H CEI�AMIC TILE FACING L/360 0 5psf NOTE: FOR UNATTACHED WALLS PROVIDE A 1/2 ; A TO 3/4" GAP BETWEEN EDGE OF ANGLE AND CLIP ;METAL STUD CEILING JOIST / " 503.224.9560 !SEE MAX SPAN MOTE ABOVE- / -- DO NOT SCREW BERC 2 CLIP TO TRACK , DESIGNATION SPACING ..MAX. WALL HEIGHT Vancouver,WA 360.695.7879 LENGTH �U—CHANNEL -- 362S?25-18 16 12 —4 TABLE MAX. Seattle,WA „ ' -- CROSS RUNNERS FIT BETWEEN MAIN RUNNERS " 'AS REQ'D 362S125-33 16" 14'-3" 1/2" DIA CONDUIT EMT 5 —10 206.749.9993 MAIN RUNNERS AT 4'-0" OC 3 4' RIA CONDUIT EMT 7'-8 " SUPPORT WITH ?2 WIRE AT 4'--0" OC OR �. ., wwwmcknze.com 6 -0 MAX # " 1 DIA CONDUIT EMT WITH #10 WIRE AT 5'-0- OC EA WAY , SGL 1625125-33 MTL STUD 127 i MACKENZIE., LATERALLY BRACE MAIN RUNNER TO 1-5 8"x2OGA 1 x " „ ( #10 SMS AS SHOWN, WALL. TABLES ARE BASED ON WALLS SHEATHED BOTH SIDES FULL HEIGHT WITH DEA16N DRIVEN r CLIENT FOCUSED ' STRUCTURE AT 12 --0 OC EA WAY. BACK TO BACK 1625125-33 15 —0 SEE SPECS 1/2" GYPSUM BOARD ATTACHED WITH #6 SCREWS MIN. AT 12"-0" O.C. MAX. ALL GRID MEMBERS AND BEGIN BRACING WITHIN 6'-0" OF MTL STUDS 1-5 8"x20GA CONNECTION DEVICES TO BE OF AN PERIMETER AND 2" FROM CROSS MEMBER SGL 2505125-33 MTL STUD 13'-6" " GYP BD SEE w APPROVED TYPE AND HAVE A 180# IN AREAS GREATER THAN 1,000 SF 2-1 2"x2OGA REFLECTED CEILING co CAPACITY. ALL LATERAL BRACING SECURE ALL HANGERS TO BLDG - �_ ,► PT STRUCTURE: TRAPEZE DUCT WORK BACK TO BACK 2505125 33 15 0 PLANS FOR HEIGHTS S ; WIRES TO HAVE A 200# CAPACITY, MTL STUDS (2-1/2"x20GA AFF AND OTHER. LARGE OBSTRUCTIONS _ � K�_1� SUSPENDED CEILING BRACING zILI JtISTRAMII� I HALL HEIGHT TABU NOTE: PROVIDE SEISMIC SEPARATION JOINTS IN CEILINGS GREATER NTS z METAL STUDS WITH MIDSPAN SUPPORT AND BLOCKING NO SCALE .�,� A .1 AW J A8. .� THAN 2,500 SF, PROVIDE HEAVY DUTY GRID SYSTEM. c� f 12'-0" A.F.F. RO-d A. .......� A. . ATTACH STUD TRACK THROUGH GRID TO4 a METAL BECK AS OCCURS ' - � - � � GYP BD PARTITION SEE PLAN BRACE ABOVE j SOUND ATTENUATION BATT SUSPENDED CLG DEFECTION SPACE AT ALL WALLS, TYP. ASSEMBLY (DO NOT FASTEN STUDS 80OS200-54 METAL STUDS p OR GYP BD TO RUNNER) ® 24" O.C. WITH 45. BLOCKING ® 4'-0". O.C. LINE OF SILL AS OCCURS s 1" MIN. f CUT TILE FOR TIGHT METAL STUD BRACING CONT 18 GA METAL FIT AT WALLS TO FLOOR STRUCTURE AT 8'-0" FASTENED TO DECK AT 2'-0 —ALUMINUM TRIM PIECE "CEE" Project OC Wj (2) #8 SHEET METAL OC STAGGERED W/ 1 RETURNS, FINISH INSPIRED RESULTS CASING BEAD ,� r SCREWS AT EACH END. STUD SIZING TQ MATCH WINDOW FRAMES USG 200—A ---FASTEN RUNNER TO � PER SPAN TABLE. BRACING TO BE GYP BD AT 2'-4" OC S.A.T. (ANODIZED BUILDING SURE �� SOUND ATTENUATION PROVIDED WHERE DISTANCE BETWEEN EA SIDE SEE 1/A6.1 STANDARD) TENANT #MPOROYEMEN' AT ALL NEW WALLS, TYP. PERPENDICULAR INTERSECTING WALLS f SOUND ;BATT INSULATION AS OCCURS SAT TYP AT DEMISING WALL OR HORIZONTAL BRACING BETWEEN BOTTOM TRACK TO FINISH FAI NEOPRENE SEAL WALLS EXCEEDS 8'-0" OC V' :� METAL STUDS SEE WALL HEIGHT GYP BD EACH SIDE FLOOR WITH POWDER DRIVEN BUILDING 4 GYP 80 EA SIDE METAL STUDS SEE WALL HEIGHT � TABLE rOR GAUGE AND SPACING ANCHORS AT 4'-0" OC 5354 SW SEOJUTA PKW' 3 1/2" METAL STUDS PORTL.ANQ, OREGON BASE AS OCCURS, SEE TABLE FOR GAUGE AND SPACING' CONT ACOUSTIC SEALANT PER 1/A1.1 x� FINISH PLAN CONT ACOUSTIC SEALANT EA SIDE AGAINST TRACK STOREFRONT GLAZING EA SIDE AGAINST TRACK {+ NO SEALANT AT SIM COND N SYSTEM � . c NO SEALANT AT SIM COND # CONCRETE SLAB` $ 1/2" MAX 1/2" MAX BOTTOM TRACK TO FINISH ___ I .—�--BOTTOM CUT TAPER OFF GYP BD ' ,� ^ r , BOTTOM TRACK�TO .FINISH r, l•• ��- • CONCRETE SLAB FLOOR W/ POWDER DRIVEN CONCRETE FLOOR W/ POWDER DRIVEN AT WALLS WHICH RECEIVE ANCHORS AT 4'-0" OC I L qy. � FLAT BASE rW NOWBEARING WALL GYPD PARTITIOI�Jt METAL DECK 6 PARTIAL. HEIGHT WALL. ;` INAL.L AT EXTERIORz �' °- MULLION , AT FLOOR AND SUSPENDED CEILING 3"=?'-0" ` 3"~1'-0" AT FLOOR ANO SUSPENDED CEILING 3»=1'-0" "_ , „ _' ' � A8i1 A8. ; A81 A&1 3 —? -O ,Q l i © ALL RIGHTS RESERVED MACKENZIE 2016 THESE DRAWINGS ARE THE PROPERTY i MACKENZIE AND ARE NOT TO BE USED OR REPRODUCED IN ANY MANNER, WALL AS OCCURS WITHOUT PRIOR WRITTEN PERMISSION , REVISIONS: SOUND ATTENUATION BATT ' --- SOUND BATT AS OCCURS METAL DOOR FRAME TO AS OCCURS � GYP BD v�"ir` 4. REVISIQN3tEVISION DELTA THIS CLOSING DATE MATCH BUILDING STANDARD GYP BD WALL AS OCCURS -- � SHEET r DBL STUD AT JAMB TYP d- I --DOUBLE STUD AT JAMB, TYP 1 1 TIMELY HOLLOW MTL KNOCKDOWN F FRAME; MATCH BLDG STD TIMELY FRAME: MATCH BLDG STD 1 SHEET TITLE: DETIALS SIDE LIGHT AS OCCURS WITH 1/4" TEMPERED GLASS SIDE LIGHT AS OCCURS WITH 1/4". TEMP GLASS �i # DRAWN BY:ALC K� $ TYP INTERIOR RECITE TYP INTERIOR DOOR Eo TYP INTERIOR DOOR A&l HEAD SIMILAR 3"=1'-0" w A&1 HEAD SIMILAR j 3"=?'-0" o A&l JAMB SIMILAR 3„-1,-0„ o CHECKED BY: MRI, AJS 4: CC F O q SHEET: I A841 I s 1 Job Na. 2160267.03 t Pppw.A1T ._ qs;/ --- TOP OF WALL DETAIL PER - ? 91A1.1 ,. I 362S125-43 STUD BRACING i TO UNDERSIDE OF EXISTING � I I SOUND ATTENUATION BATT : . . \ FLOOR/' ROOF 0 6'--0" oc . AS OCCURS , ALTERNATING WI (2) #B . .f WALL BEYOND \ \\ I SMS At EA END \ \ Architecture Interiors l \ \ I \ \ Planning Engineering ng TEMPERED GLAZING PER \ \ \ I I SPECIFICATION \ \ n 362S125-18 @ 16 oc TEMPERED GLASS LIGHT \ I AS OCCURS BUTT GLAZED SIDE \ BRUSHED ALUMINUM 45' I 45 Portland,OR CHANNEL 503.224.9560 . t SAT CEILING PER PLANS RESILIENT SPACER - FULL GLASS DOOR ,� f I - Vancouver,WA " © ATTACHMENT 360.695.7879 1/4 TEMP GLASS I I LIGHT AS OCCURS o Seattle,WA . FLOOR FINISH 206.749.9993 w f B GYP BD www mcknze.com - _ B'-10" AFF GYP BD MAG[f N DESIGN DRIVEN I CLIENT FOCUSED 3 IN . i GLAZ GHNCANEL s TEMPERED GLAZING PER SPECIFICATION FLOOR SYSTEM - �' WALL BEYOND z i l i 1 GLAZED DOORK�2 RECITE SILL DETAIL ATLCJOR f3UT!" GLAZING HEAD CONDITION A8.2 3"=I'—O" o A8.2 1 1/2 1 A8.2 1 1/2 1 0 Rtat �ststaei ' . j ff 1 I I 3 , CEILING j t IProject INSPIRED RESULTS I SUITE 100 t J : TENANT IMPOROVEMEN o 1 BUILDING 4 � A8.2 \ � \�. ..4:;± �' I P5350�SWN$EQUC)IA PKW 00 , OREGON J' 3 f ; • \ r 3r-2" L (6) EQ. 2r " ILA 5 A8.2 23 —8 f 5 - 4 CONFERENCE WALL ELEVATION ;. A8.2 0 CONFERENCE 102 � w MACKENZIE 2016 { © ALURIGHTS RESERVED THESE DRAWINGS ARE THE PROPERTY OT O BE i MACKENZIE REPRODUCED INNTED ANYMANNER OR WITHOUT PRIOR WRITTEN PERMISSION I REVISIONS: � z NFa- REVISIONREVISION DELTA THIS CLOSING DATE SHEETi . 1 i { ! i l ! � S SHEET TITLE: DETAILS AND . WALL ELEVATION , 1 t i I DRAWN BY:ALC CHECKED BY: MRT, AJS SHEET: 1 a 7 A80-2 , I JOB N0. 216027.03 I t mrnk�rr n=T. n*/on mg � r _ # 1 a D E I _ 2" VERTICAL 1 DOOR TRACK EXISTING BRICK Architecture Interiors ti I I i i, i ! t 3 # I# I # I I l... ?_l_l: s .__ -{ -al- - f M L STUD i �:If , � 'f E }({f;�r, ;!jtiFlS � '}� f � ` � ��� t� i }I �1 T ( _ Planning Engineering ' i..�..1.1_t ....t ..�J. t...1?.j.L1_I 1 .i. . _. . , � .i � ! �.�_ f� 1 �� :2.^":": '_ ", :",_.._;.::'Y.'•_.5:"�:_.!:.'""�"1.,.:"}. _x:..�b:.'"':1:�';.`t.:,.a.. ,T:;..,t. _t:-.i.;'.;'...�._:L'::1'�_1._..3._ _":.t"t"r::`»J. ..i....L,. "'7._:T.«..X. .,, •':_7_..s.... ... _ _'... _i_'='G.�,X:.__ .__:L ..:'.• .'_'-T..,_t_:»:..L...«T..'!.. �+-/ ._L_.7. t _ L 1. _,! .� I.. L._.L m#_ .7.., ?_. _e_..:. t__.L_t_ � ..�., 1. 1,..wi:. .Tw' _i�_�T,..4 t.. ? ..i' S _i_ .? L C'..��.J.. '._C._.T..S ..t ?',..t_»_E_.__? i t i_:_E_`r L 1.��r _7 .1_..I....T I ..i. _I� I.'T ±.:7_ T_...J t t r .�: r _ _.l.....C:-.r:.,,.x._ J..,....,,:..-#-•--1_,.-t.. .i: i.. ,7. .x..: ._..I.,.#....}..,....:_ ..;�.:._...,.. -- _": .i-,__£_ , .I. ,.T_"..I'_,...C..:# _f ....,_t.._ ..3.. wi_ T l.. T - ?.._.�.._7_ x_. rx__,;Y _ ! r.. #..,..t _.7.__,.. ;.... _._}, ;. .�.. *..,,._._r �#...z. x_...t a_ r a, s_r. r- _ BATT INSULATION 1,. S_. T - ; y i.,.. . Tr.Cyl S. 3 rL.. . ,-.#_t v, t. ? ! #. T_ NC� S...I` # '' _.�. _ L: - �.. t_ 7- .I-J t.._ I "�1-L7 T EXISTING BRICK ? . .L .r r a._ �:;...! -f`x;`. .T� "--_1,.z_x .�, z`c`��, _ ANCHOR :.., s.?_ . _.�.. ...?_ c-` r HORIZ. TRACK r ••r--t- -, r r , 7 «. _ f ..x'�. .amT_r�'�:.T �--r-I--}-._ 't., ,.%r_ ..L.,..}:'� #_;_ ,: x .,r..,_..�._-.._.�_ -t.,._L.. r.-L. I x aM. :`_s,':,, _.` .:'°1. _: i__ _;_. . _._ _?_ ..a !. -cc .a._ r _� fir 'r -r `z. . .__ `-rLx r rr SUPPORT ,..1. .1_�f..rL:,_;,...,t �"�i.:.,t...C_ .I_....�..r.. ��..ri " :I' _::....# ., i.,�_,_i ._�_r_i.,_�,_,_I_ ..__-'` �,.t ..i:ti.�:. I'..�7`�.,�_ „x.L••':C �..}✓� _L. �....1 -1. �_7_ 'Z � ADP E - HE LAT L T..' Z C,S ,. .L. .7_r,_:w !..,I,r..t_r_,.., ;_ ,, _.: , r;_. 7_ #7 _.7w_I. ..L _!.. 7 a rT _.a r T p r j�.,..__. _k. x. ..' s_ r _.Iw s,. .r. ~�. .. re_s .rix. Portland OR I ��Y, _�. _ ', T T-w.r._L �l�.: _r T.. S _.,1 r ._ ..v7 r.,.- ..i.,,_]. .. 4_....-r .._w_:._ t =-r' t T z.. _-J.-__ L L �. :_r,_.1_,.�. I__ .a•.. a..,..., a, L _?_.j #. J_ a.. T a _t.. #., ��. r, �r . J x~-I. �iL LAS . so .zz4.9560 I t"'t-i -t "#_- Z ,..,T. r. .t -t •r" r _ - � :l`..x_ s...s.. :�.- �I- �--1..`.z-;z�.. .c :`� r_.,"x._:r: -,-J... ,x--r-a~� r -:X__:L.. i.r.L . .# .._3�",7;':r._r,• i :.'.•' _ L .0 t_: I . 4 , ' -,, 1... .i__.1_.r �,.' r .-t.x�.1 r.i..#.k_ ; �, ._k, •.:_�, r S SzT L L. ,7. .a_I T_ �. T� w T r r r P'T .r_ p`i ' t. .T I t -' :r.: T I. [..I r zt r i r I X r t # Iii #r- I Ell ;��{r , # .�( II; I :z__;, r_w;?=' _ r Ej�# ►III I I ! I Vancouver WA s_1. r 360.695 7879 '�' r., ri_-•_ _ r..i_ s ,1. _,J...... _ ..i. _.t_ _ ..1 t �� _ .._#., ._3__.,_`._,-T'...J.._•_,_,_4,_ ;a`.r-.._.Y,-�4_..-.'�..,...J...,"�;'.r..l. ..r.,.�_ _•. .,..;__5..,..__._.._. > �:~� � .�.L_r. -.i'..�l„ .�.,'`._�• ..I.. : _..� ..7 � - .. ..... .. ,-.t.r -- . • • t_ ;.., s _ . _ �.,.. _ �- -. �- "' �..r` .a•--� • � � Seattle WA . -S..._L___I_._:?-•:`r-��s::`:t--:� �._.,_-,-, ,_.,,,.__• ... ,.Z:,..: r --x•.s .,c. I-a-x_�._`� �.,._ .r r:-; --�T t , ,c.., _ �. : wx.. .1._L., _. ..,. ... -s t .. ,,Z_ 1_ .....,TL-_ ,S i L .L -_ i 3i F r� _.t I t - ? ._#._L C_ .,__._ .L _,.. ?._. - r (-.,_.; .I',.i.-_ I t_ '_..f ,.t.,.-I :-} 'r.%, r_T _ J- -_ ..I. #_ 7 "T I sr. 7 T J -1 0 _.�:. �-r �•� �#• 206:749,9993 ��. _L'"`..1:. x,_3.,•.7,± �..,.,a:.�1r_T �L . � .L. �I;� T.'. _E_ T -.:�. _��,..I,. _.r, _ .,_,•.t:i-i: :#;- ,..,�,� -� I`.�.�.. 7: i, �. •.� �x�--r- -s., -t-,L�Z Z _ __:L..T' _3._ _C' •.....r�"•- .l.. - • ry Y I' � _ �t � „ .#µ..ms# ._�•.,_. .a_ u.-.x_ __i�:f-- i . :�..-�,i......i_.�; .i.„#.a : '3•. _ _ �..r:`. �..i t.>.. �. tT T11 , T - `j OL 9 T r.� x�__ *.r`?.rr. `�.# r_s x;x ..x, x_ .._t.z; r _..::r r `�., 3# .{_:.i T ,.Y f __ - www.mcknze.com i_...i. -r_Z --,..�,`�,-S. ._ T/OPENING MLx_r r�,_r._ . r �J._r�I � a r ;e _iMACKENZIE r...,_ _t 4..•C-_ r -Ir s..,_Z,._._ Tn_.._# t_,_L. r�.r. ,. t `r` ' # DEMO ISTING- STOREF NT ao -h 1/2„ DENSGLASS BACKER ROD 011510"DR1V11" f CURT RDCV6110 "a-'a-. __ _.; HORIZONTAL a ..�. £.;.�. ..w.._: w DOOR TRACK & SEA ANT __r,a_..._r:Z...�,,z�•s_ta _"a h;t ,_'k_-r.,.�.r.--I IIa_r---t_:.},.;.�r.`r_ a.". ,rwr--i"�.i.�a_.',, • ; �r�:,j1.. ' WEATHER BARRIER v . ...t-. .t1..,.. ..�,. .r.:. " BRAKEM.7tOVERHEAD DOOR k-`_ a-J., / / � / 4•. - " - 7^T,.`,.i - z�_:L. .Z_r �_ r�. .a i._•._,��_.,,.-.'.i__..;,. 1' r ,i;.:•L,....�_ �,.... i_�:..i..'_r_., _:r:'..;.n'-•_:.i,rs. i i - "�' �Q�, �- » „ _.O.-0„ TIACK LENGTH, REFER TO MF R, �. T/FINISH FLOOR EXISTING DOOR o „ +/- V-6 „ EXISTING STOREFRONT _, 3 x 6 HSS COLUMN _ }. fj7 i O IV l�tTNC, �.SN1TNELEVATION INFILL FURRING -- "� „_ ._ „ w W/BATT INSUL I Off ERNEAD DOOR HEAD „ , . A$ 3 E 1 j4 --1 0 + A$,3 3 --I -0' a { ' . o LEAVE EXISTING BRICK #:,-S•FI;._-_.s_,„..II._,,.`_�#j.-t7i._..j_%�N..._L.3-�#L-_.-�,r..k..,...--I.#_.�-.!a_.�._IT_._,.y..�#1-.�#L..I�..rL;.�.{.'....�rT.',._il_._.,rA.x,_..JiI..,,._.�,I.�,I7:w.�t_�....._�,,#. _,,.. 3I:. �,.t, ,�.,.__`:._,��#, I$�; ��17.i.__,#�!�;, r,I L �s::ifi:1{t ,[ I` rMI t:. :5_.'.?t._,a_.a.. -.z..:�:: _..r.x.••-..`(�.af' r••�- •.r_i�r_ -a._.�_..�.rt1-(x_f 1 VERTICAL DOOR TRACK#{ U. ,� . LLt_ ` _ rl. -t � _ T +j 1 -6 /2 T' C, I.. _I_ _rte L ,k._T i _C .3 :, ? ] _t_.r _L l _ I �:_i,:. .:,.,,.,,L _t.,,..I--r:i` _.i.:�..;.. �L' 1"��is�:#�,_.._ _�.r.J..� 7 ?: ...�. _'.I," Y, ""1_.r- _1" :z._.... .1_..� r. i . z..r. �. t ` ; _ t_.T rW.•__ r__.:., -.� ;.:. .,,.., r r �. 7 . ,a: �,r 1. ,_ r: # `, _.. x...1�f VERTICAL ,_.a_ r i_r_L. ...,_,r �. r _�. �..__az._,Wt,t _.c,a ,-x_r_ _�. .�„z.,,.__ .... =- - z_..._• r.. t�-� .i._..7 z.. i_.a _� .r _ra_ Z _ �c. WIDTH OF NEW -.T7L_-7.77r`�__.'"T_..f r,'_7.r.a.r._._._Zr,.LL___..:.,�,i:,.�__.r:_�.,•.__-�.r�-._.,rIIf_.';_y.Ttf_'..1_�r r"_-I=.�._.`.._-_za__-.._.7t.r�__r_._,,_._..._.�S.,�Lc_�.r':..,__.irLr_.7x_..-Tr'Ii_:Z_MI_,..i;_yk.'.:,7.-L_,..'-..<r?I":._,.'�Yrr,�TIlr_.:.�.�Lr..`.zx.i 1.....,1T r k-Z?:,;.._.._...,,,.,L„"....}LL,,_..__.x,>'".t r-•fit1 7' -x_,,�-C STDREFRONr TRACK ND j_7_.__tr _ DOOR WALL BEYO WALL FLUSH C avrr =;:cs�_t_z, jr.IaLr Y r .7 . 1r PSINroUS1 eITPc#EI RE100.rr_t_ rLr.s ;= £ .; -2. - ,A `' T , , EXISTING BRICK ENANTD IM RPEOSRULOTVSE MENT �i it ,Hill � VIII 11 I 'r' r c' _ �a' wl I` ,II �( � Ii ' �' i � I . : _.r .r _ t_` , Lr,i_ E I -� r r -'..G,. 7_ ..C.....;__T `;:_ �a-:4.:,.i..". r,,;i,T.L. y l._.Z, a_ L_ _.� .Tf :;_ r ?::` �'C_ 3 , 1 ., #.3..r. _.L.;. ,- -!_#_.. . rJ_ ._ 1 �... x .z �z x z__ :s _ c. c0) GRIND SLAB. S_J.__.r. : .rrx_,.' rix"= _ -1- -r OVERHEAD DO .ri C_T 1..�!_. T 5.._I. 7 * , i :r:�:. _<: 1._.�- _,T��:7 w� �_ T T •.I .t , 7 _ ST. . -- TO SLOPE �Q.DIN . 4 �` .t.7 ,.T f �. : .y I 1I # r I AND SEAL GUT REMOVE SEQUOIA.PKW . ___. - ��_. _::�_ . r -► r ._,_:~ . ^T #_ :I: #; f r .I k i _�.� � I � rfi fi� 1 �� � SW T QPEIVING r_': _ NGLE P��11.1�ND C}1 :� C}N TIOPENING L., 3.. r• -°- DOOR BOTTOM ; R OPENING F II I':L= i fir' _ 3 =1 `I; '�I ,:}. "r i._f s"F'.; _.Cy{ t EA VE I.- r .,_ T L, =`- __r �-`r / =_:, _^, r_.,_.-=_._,_ �: AS EEDED .y T T 6 SEAL _. I rTa �s r �_W _ c EXISTING r QTµ - �, :x. �; ` , `-r. t L* EXISTING SLAB ON GRADE __ A8.3 „ , �. , I � ,.__ a ...� i �, �Iic r n .r / f TOREFRONT ' �:. � � _#..z_. y-� , ,f /; j4 CHAMFER YT+:;3Tr-' `r'*'i-' I NEW PATIO t I 7 AT OVERHEAD SLOPE :}' f. : __�. SLAB OVER s ,;+ r _ 7 ?. „a ,�'` DOOR, TYP. 7 _ 7 4I- 1 y� w _ r_ ,>• �-t_:t."I. !:. 1,�_ .:_r, ;•;�- � �/ �/' � ,_ .. a � •.. _ ..,_ CRUSHED ROCK � ADAM,l 4 d A8.3 _.s_t L' ::,:'-�_s.r_s" _? _.L_t_z.r.z:r r,,_ ,za.. r _ s #_� ` r '? f / //i M I:. 1_ 7 _ r ""-r f T # _ s A wt .3 F ;i. 1w,w-rw� N d !r }{•� fI .,T , ,i.,.. t r^- :,.. .�._,_._,.v. 0REV N _ y� .�• ,e• ,, R , `h �� � �.. I � �__�. 4 •�: 4 .. ..._r.. r-.4 �._ ,..:-r.s.I, _T _ _,"_ f f •w _w,+•....,_-t 4 111 aj„ v Q, -5�i4b3Y 'r k z.. _ NEW SF a . . _ _ r _ Lof .T_._I_._ S ,3._ L.r_ :S 3. _7. 1tt A' a A q i_ C 7, F. #._ L,I T._- M� = - �''' T T T T1>1 j �� .:t: -I i �1 I I•---••-I I �•--•---•-I I 1=1 � I�I I I=L :-== _ .. •� Q' t' ,.. I I nw:,,.v T/FINISH FLOOR ( ( a ___�. �I �I 4 Q BICKER"ROD " II I III d AEXISTING DOOR NEW SF NEW OVERHEAD 5 NEW PATIO SLAB MACKEN ZIE2016 ALL RIGHTS RESERVED Z OVERHEADDOOR ELEVATION W SECTIO ,` C� _jTHESE ©RAWINGS ARE THE PROPERTY' 3 QVERh��ADD �R � 0 O rR��AD DOOR V �� (r) MACKENZIE AND ARE NOT TO 6E USED _ I OR REPRODUCED IN ANY MANNER, A$.3 {/¢„"'I'--p„ O A$.3 t/2"-1'-©„ A8.3 3"=1'-Q" ? WITHOUT PRIOR WRITTEN PERMISSION UI p E REVISIONS: k _ - - - Z P.T. BEAM ABOVE REVISIONS REVISION DELTA ��.d I „ 5:-j THIS CLOSING DATE 2 VERTICAL TRACK ASSEMBLY as 'SHEET ; II I II OVERHEAD E D DOOR EI 3 II 3 5/8MTL STUD i II II „ „ fit. , cr II L, I II 3 x 6 x HSS w II�HORIZONTAL DOOR TRACK # II BRAKE METAL COLUMN SEE DETAIL A$,4/5 TO MATCH SHEET TITLE: II ; II ti: STOREFRONT s OVERHEAD (( VERTICAL DOOR ITRAC t, f DOOR DETAILS f 7 II OVERHEAR II P.T. BEAM STOREFRONT WINDOW ►• + A8,3 II DOOR = II q8,3 ` 1/2 DENSGLASS ( ( SHEATHING - ---- - I - BACKER ROD & SEALANT ---BATT INSULATION DRAWN BY: JAW ' ''; ? .:. .;�.. : •' , ' , . ,► +, • . STOREFRONT $ OPENING WIDTH CHECKED BY: AJS WINDOW BRICK FACING r:• 'EQ A , •:• i EQ wry SHEET: m } QVERH�A� DC��R JAMSirs fJVERNAD DCCR PLANK`7Q A$.3 i A883 , A$.3 T - o JOB NO. 2160267.03 PFRUIT I=T: nA/9A/16 i ANCHOR BOLT M Architecture interiors ! Planning Engineering z - � 1 Portland OR. . f 1" GAP - �• � r 3x10x3/8" 503.224.9560 ' r. Vancouver,WA �r 360.695.7879 Seattle,WA .206.749.9993 { www.mcknze.com BOLT w " MACKENZIE.' - - TRACK @SLIP - r � - � VISION ORIVCN!C4iBNT ROcuslo CONNECTION ## f 3 x 6 x " HSS j COLUMN ( l F. ^.c- -R 0 a HSS TOP CONNECTION DETAIL ,r r " 3 =1 -•O o A8.4 � > o I 3 x 6 x 3/8" HSS COLUMN t - Project INSPIRED RESULTS r EA. SUITE 100 SIDE TENANT IMPORQVEMENI f E31.IIt.,M 4 5350 SW SEOUOIA MW L4x8x318" POR'T1.AND UFfiE�C►N • W{/rr-n 2) 112"'0 ANCHOR BOLTS 4 MIN EMBEDMENT �f t f Def " •z to MACKENZIE 2016 jt q Q ALL RIGHTS RESERVED { uSS THESE DRAWINGS ARE THE PROPERTYJ # IBOTTOM CONNECTION Dr—TA MACKENZIE AND ARE NOT TO BE USED; OR REPRODUCED IN ANY MANNER, WITHOUT PRIOR WRITTEN PERMISSION REVISIONS: N5< REVISIONS REVISION DELTA } &I THIS CLOSING DATE { W SHEET t o t I _ - t ! f j { { I a SHEET TITLE: tJVERHEAD f DOOR DETAILS DRAWN BY: ' JAW CHECKED BY: AJS SHEET: A8w* 4f f JOB No. 2160267.03