Loading...
Plans (4) 0 --itz BUP2016 - 00062 M RECEIVED FEB 2 4 2016 CITY OF TIGARD EXPERIS BUILDING DIVISION TENANT IMPROVEMENT Architecture Interiors --------------- tip + LINCOLN TOWER Planning Engineering N 10260 BW GREENBURG RD Portland,OR 503.224.950 TIGARD, OREGON Vancouver,WA iE 360.695.7879 +4y_ INDEX OF DRAWINGS '�___..� :_::::::_::��_:__:______ :>_. ���y .:... :::.:::.: .= Seattle,WA m 206.749.9993 T1.1 DEMO PLAN, KEY PLAN, SITE PLAN AND NOTES www.mcknze.Com A2.1 PARTIAL FIFTH FLOOR PLAN, DIMENSIONED ELECTRICAL PLAN, ENLARGED IT EQUIPMENT PLAN AND NOTES MACKENZIE A5.1 CABINETRY ELEVATIONS, DETAILS AND SCHEDULES DESIGN DRIVEN I CLIENT FOCUSED + , ;i '+ +28+ .ri3 A6.1 DEMO REFLECTED CEILING PLAN, REFLECTED CEILING PLAN AND NOTES Client 284.:1 -- -- A8.1 DETAILS AND ELEVATIONS -- A8.2 DETAILS AND ELEVATIONS ,i+ A"L i =r:NEMA ; . ._ . SCOPE OF WORK .� 44:�_3 - A;------------ '=u;_ H ; r: ;�______________�,_._____. __ ;� THE SCOPE OF WORK FOR THE PROJECT INCLUDES INTERIOR TENANT IMPROVEMENTS fiaa_�., ;iii ' jFRSFTOT W 30:AMP :._: : ` a.✓,.,. t'v'4, - ,.., �.,t+..d-s f44 ;3 FOR AN APPROXIMATELY 5,530 SQUARE FOOT TENANT ON THE FIFTH OF TWELVE FLOORS. +8i aE i i+44 WORK TO INCLUDE DEMOLITION, NEW WALLS, DOORS AND RELITES, AND NEW CABINETRY. 444:. DOCUMENTS ARE BASED ON TENANT'S 11/24/15 DESIGN SET. LATER UPDATES AS CONVEYED IN TENANT'S 12/2/15 DESIGN SET ARE ALSO REFLECTED IN THIS SET. „ CONTAC."IrS. Project i: FE y Y.J 4_.__a ___IL:::: - �-- ---�:::=-- ' '__-_____ _______ EXPERTS FE a V ARCHITECTURAL PROJECT MANAGER: SUITE 5 KIM FORD, 503.224.9560, KFORD@MCKNZE.COM T'ENAN'T • e� I IMPROVEMENT -----------::::_:: ---::.--- EXP RIS PROJECT MANAGER: ERIC BABULA, 414.906.7116 (OFFICE), ERIC.BABULAOCBRE.COM UNCOXN TOWER DESIGN INTENT CONTACT: 10260 SW GPEENBUM RD CINDY CHRISBAUM, 414.881.0209, CINDY.CHRISBAUM©CREATIVEBUSINESSINTERIORS.COM 11CARD, OFIF' ON +, EXPERIS TECHNOLOGY COORDINATOR/PROJECT PROFESSIONALS. JOANNA ROGERS, 414.906.7400, JOANNA.ROGERSOMANPOWERGROUP.COM A � WILLIAM SEAWALL, 414.906.6241, WILLIAM.SEAWALL@MANPOWERGROUP.COM CORPORATE CARPET CONTACT: L K =t; - +8 DENISE KIRSCHMAN, 262.442.6604, DENISE.KIRSCHMANGSHAWINC.COM .� is ���- � F� �`z• �,�� �L:� 13 TENANT APPROVAL: PORT D, 0 • TENANT TO REVIEW DOCUMENTS AND PROVIDE APPROVAL THAT DESIGN INTENT, ELECTRICAL/DATA ROUGH IN LOCATIONS AND IT EQUIPMENT REQUIREMENT INFORMATION 1 DECO PLAN REPRESENTED ACCURATELY. 1 OF HAS BEEN DESIGN/CODE DATA MACKENZIE 2016 ALL RIGHTS RESERVED GOVERNING CODE: 2014 OSSC THESE DRAWINGS ARE THE PROPERTY OCCUPANCY: $ OF MACKENZIE AND ARE NOT TO BE USED OR REPRODUCED IN ANY MANNER, CONSTRUCTION TYPE: TYPE I—B WITHOUT PRIOR WRITTEN PERMISSION TENANT AREA (APPROX): APPROX. 5,530 S.F. OCCUPANCY LOAD: 56 REVISIONS: z 20 REVISIONS REVISION DELTA 2 REQUIRED EXITS, 2 EXITS PROVIDED CM OF TGARD > THIS CLOSING DATE BETWEEN 1/3 OBOTH EXITS ARE NEW AND WILL HAVE APPROPRIATE EXIT SIGNAGE tEVIE'OGED FOR CODE COMPLTMCF o SHEET DISTANCE 1 F DIAGONAL EXITS = 4BETW" 42 F D BUILDING IS FULLY SPRINKLED AND HAS NEPA SMOKE DETECTION ,Appy WITH ON SITE EMERGENCY GENERATOR FOR FIRE, LIFE/SAFETY BACKUP POWER OTO t 4,— SW i.awel Spent ._ .._- .. DEFERRED SUBMITTAL u s' �'`> Iir2014 OSSC SECTION 107.3.4.2 (by separate pelttj I#fi FIRE SPRINKLER Br. �+ FIRE ALARM «+• .7 't `/. STRUCTURED PAitKWG.. �l F: ;L :, - MECHANICAL ELECTRICAL IF CCP ' ETAa LJ ¢'z` � ,� PLUMBING SHEET TITLE: h ax Sfp rS 1 EXIT ILLUMINATION DEMO PLAN, KEY E NOTE: DESIGN BUILDERS FOR M.E.P. AND FP. ARE FULLY RESPONSIBLE FOR THE DESIGN AND CODE PLAN SITE PLAN ¢ R, r COMPLIANCE OF THESE SYSTEMS/COMPONENTS. THESE SYSTEMS/COMPONENTS SHOWN ON DOCUMENTS AND NOTES :. �SCHEMATIC ONLY: THEY ARE NOT INTENDED TO REPRESENT FINAL/CODE COMPLIANT DESIGN. 4 _ PROVIDE DESIGN DOCUMENT SUBMITTAL TO ARCHITECT OF RECORD FOR REVIEW OF GENERAL LAYOUTS Y $Ny ONLY PRIOR TO JURISDICTION SUBMITTAL. IN ADDITION TO SUBMITTAL TO ARCHITECT OF RECORD, PROVIDE K lawDESIGN DOCUMENT SUBMITTAL TO DESIGN INTENT CONTACT FOR REVIEW & APPROVAL 0F ALL EXP RI E S SPECIFICATIONS PRIOR TO JURISDICTION SUBMITTAL. � n . AREA OF WORK . .. :'°. _ `I STRUCT6RED PARKING 9T(t6CTURED PAfI"G LEGEND .. DRAWN BY. LER Q AREA OF WORK ==- == EXISTING CONSTRUCTION TO BE DEMOLISHED SWoSkB> CHECKED BY: SBH/PDK �. -__ SHEET: EXIT REQUIRED EXIT 2 KEY PLAN 3 SITE PLAN 111 FIFTH FLOOR NTS -n.1 NTS DEMOLITION GENERAL. NOTES TRUE PLAN TRUE A. ALL EXISTING CONDITIONS TO REMAIN, UNLESS NOTED OTHERWISE. NORTH NORTH NORTH B. CAP ALL ABANDONED PLUMBING, ELECTRICAL CONDUIT AND OTHER SLAB UTILITIES AS REQUIRED. JOB N0. C. PATCH AND REPAIR ALL EXISTING WORK TO BE LEFT IN PLACE THAT IS DAMAGED DURING 2150954.15 DEMOLITION OPERATIONS. D. RETURN ALL UNUSED ITEMS TO LANDLORD. PERMIT SET- 02/19/2016 215095415\4_DRAW►NGS\ARCHITECTURAL\15_T1.1.DWG LER 02/18/16 14:59 1:96.00 CITY 0,77 TIGARD Approve' '- Planning Date: 4 / ) La Initials: P-1 0 +, 23 01� . 10'-5" 11'-5" 10'-5"± 4'-8" OFFICE QII Architecture Interiors o 8 Planning Engineering INTERVIEW OFFICE 1 ROOM 3 502 503 I 504 soSA s t 502A 5 5 503A 504A Portland,OR 1 -_° wizu � 503.224.9560 EXIT 7 RECEPTION 506A 5 17 TIP 7 Ca Vancouver,WA 14 > 3 360.695.7879 6 3 EXIT 6 00 A2.1 Seattle,WA 9'-4"t -I 17'-10" 206.749.9993 8'-0" 1 8'-1" 1 Sorg 4!_0" www.mcknze.com `i IT EQUIPMENT rn , CR 7'gDV77"' - MACKENZIE. DESIGN DRIVEN I CLIENT FOCUSED 3 519A _ ''+`521A I B B513K IWA512 G16 15 ii� Client co A C " I IT OPEN _: CR � I °° A5.1 22 51oA I N AGE OFFICE - - -- 8all2 O .� \_bOR 11 +i 20'-6" HALL 5 13 5'_O 9 d- >f TYP. M ! !! k w >; 519 52oA OFFICE WORK/ 5 2 CLR. 2'-11" 8 _vF CR 32 -11 LZ 3 h 2l 20 COPY cy HALL CLOSET 1 }� ^ I tv 520 _-- 514 sA TYP, 18 :t= + r { �� 509 510 So TVP. 21 13 CONFERENCE 518A 515A 6'-9" 0 13'-4" 5 17 TYP. 5 A 5 -fl 19'--6" 518 15'-10" 6'-5" 11'-4"f b (° '9k 0 OFFICE o 17 TYP. o Project CL-: 508 18'-4"± ± o EXPERTS co OFFICE 517A 5 " 517 13 5o7A ��?, 4'-0" :d. ►- SUn�E i �, O TENANT 13 OPEN o TVP. IMPROVEMENT - - - - - - 515 CONFERENCE 13 5 0 TYP. 24 507 4,_ „ 21 s'-2" �`' 21'-10" L KX)LN TOWER 4 ° ® 102W SW 0AEE WRG RD COFFICE 516A 5 TYP ' "17'-2" 16#-7 -11"" 11' TIGARD, OREGON I I516 " `� 8 ,w cv 4p-O" rn d 18 2 19 13'-6"f TYP. TYP. TYP 8 9 W 1 23 PARTIAL FIFTH FLOOR PLAN ri DIMENSIONED ELECTRICAL PLAN • PORT REG A211 1/8"-1'-0" A211 1/8"-1'-0" LEGEND GENERAL NOTES KEYNOTES F NEW WALL TO UNDERSIDE OF GRID, SEE 5fA8.1 A. ALL EXISTING CONDITIONS TO REMAIN, UNLESS NOTED 1. ALIGN NEW WALL WITH EXISTING WALL. O ALL CKENZI RESERVED ORIGHTSTHERWISE, 2. ALIGN NEW WALL WITH EXISTING COLUMN. THESE DRAWINGS ARE THE PROPERTY B. DIMENSIONS REFLECT FACE OF FINISH TO FACE OF FINISH, 3. CONFIRM EXISTING WALL TERMINATES AT STRUCTURE. IF NOT, EXTEND TO STRUCTURE AND PROVIDE NEW WALL TO STRUCTURE, SEE 3fA8.1 OF MACKENZIE AND ARE NOT TO BE UNLESS NOTED OTHERWISE. INSULATION IF REQUIRED. USED OR REPRODUCED IN ANY MANNER EXISTING 2 HOUR RATED WALL TO REMAIN, SEE DETAIL 4/A8.1 C. WALL THICKNESS ARE NOMINAL, UNLESS NOTED OTHERWISE. 4. CENTER NEW WALL WITH EXISTING MULLION, SEE DETAIL 6/A8.1. MODIFY EXISTING WINDOW COVERINGS AS WITHOUT PRIOR WRITTEN PERMISSION D. ALL INTERIOR WALLS TO GO TO UNDERSIDE OF GRID UNLESS REQUIRED. EXISTING 1 HOUR RATED WALL TO REMAIN, SEE DETAIL 4/A8.1 NOTED OTHERWISE. 5. NEW 2'-0"t WIDE TEMPERED RELITE TO MATCH BUILDING STANDARD, SEE DETAIL 8/A8.1. REVISIONS: E. ALL INTERIOR DOORS AND FRAMES TO MATCH EXPERIS 6. PATCH AND REPAIR EXISTING CORRIDOR AS NEEDED, MATCH EXISTING FINISHES TO BUILDING STANDARD. NEW i HOUR RATED WALL, SEE 3/A8.1 STANDARD UNLESS NOTED OTHERWISE. SEE DOOR SCHEDULE ON 7. PROVIDE DOOR BELL AND DOOR BELL CHIMES. CONFIRM FINAL SPECIFICATIONS AND LOCATION OF DOOR oh REVISIONS REVISION DELTA A5.1. BELL AND DOOR BELL CHIMES WITH TENANT. PROVIDE APPROPRIATE NUMBER OF CHIMES TO BE HEARD >-J THIS CLOSING DATE EXISTING DEMISING WALL TO REMAIN, SEE DETAIL 4/A8.1 an SHEET F. OUTLETS INDICATED ARE EXISTING UNLESS NOTED OTHERWISE. THROUGHOUT THE SUITE. COORDINATE REMOTE DOOR RELEASE WITH TENANT IF REQUIRED. -, M" : V41t ->; MA. -� '- -- - - NEW WHITEBOARD PAINT, WP-1 SITE VERIFICATION HAS BEEN PERFORMED (ON 02/12/2016, 8. CONFIRM FINAL LOCATION OF FLUSH FLOOR ELECTRICAL AND DATA ROUGH IN LOCATION WITH TENANT. WHILE VACANT) AND PLAN, ELECTRICAL AND CEILING 9. PROVIDE 1-1/2" CONDUIT FOR VGA RUN. CONFIRM FINAL REQUIREMENTS AND LOCATIONS WITH TENANT. D ® NEW BASE FEED, (2) CIRCUITS INFORMATION HAS BEEN UPDATED (OBSERVATION IS LIMITED 10. PROVIDE PLYWOOD PHONE BOARD. SEE DETAIL 10/A8.1 FOR ADDITIONAL INFORMATION. + + NEW FLUSH FLOOR ELECTRICAL AND DATA ROUGH IN LOCATION TO VISIBLE/ACCESSIBLE AREAS). CONTRACTOR TO FIELD VERIFY 11, PROVIDE STANDARD 8-GAUGE WIRE TO ACCOMODATE TENANT PROVIDED IT EQUIPMENT RACK GROUNDING. r-EXPERIS RACK AND CONFIRM ADDITIONAL REQUIREMENTS WITH TENANT. CONFIRM FINAL LOCATION AND REQUIREMENTS WITH TENANT. 32.5"x13.5" EXISTING QUADRUPLEX OUTLET G. ELECTRICAL, DATA AND SWITCHING LOCATIONS INDICATED ARE 12. PROVIDE CONDUIT FROM BUILDING DEMARC TO RISER CLOSET TO TENANT'S DEMARC (IT EQUIPMENT ROOM rv' SHOWN TO CONVEY GENERAL INTENT ONLY. COORDINATE 521). CONDUIT FROM BUILDING DEMARC SHOULD BE THE WIDEST THE LANDLORD WILL GIVE. IF LESS THAT (1) DEDICATED D ° NEW 120V/20 AMP DEDICATED QUADRUPLEX OUTLET ELECTRICAL/DATA AND SWITCHING REQUIREMENTS (INCLUDING 4"-5" THEN (3) WILL BE NEEDED. CONDUIT FROM RISER CLOSET TO TENANT'S DEMARC SHOULD BE AT 120V/20AMP -.-_--------- 2) DEDICATED LIGHT ZONES) WITH TENANT AND PROVIDE DRAWINGS BY LEAST 1-3/4"-2". FOR SECURITY 120V120AMP c NEW QUADRUPLEX OUTLET DEFERRED SUBMITTAL. CONTRACTOR TO CONFIRM WITH DESIGN 13. PROVIDE BLOCKING TO ACCOMMODATE TENANT PROVIDED WALL MOUNTED FURNITURE/EQUIPMENT. SEE D NEMA D D F PHONE INTENT CONTACT FOR FINAL DIRECTION TO OFFSET OUTLETS, DETAIL 11/A8.1. 1 , 11 A '*tr I BOARD 9A NEW OUTLET AND VOICE/DATA ROUGH IN LOCATION DATA & SWITCH LOCATIONS AT A MINIMUM OF 24" WHEN 14. PROVIDE BLOCKING TO ACCOMMODATE TENANT PROVIDED SIGNAGE. SEE DETAIL 12/A8.1, COORDINATE WITH SHEET TITLE: z£ ° NEW 120V/20 AMP DEDICATED OUTLET LOCATED IN SHARED WALLS TO STRUCTURE BETWEEN OFFICES TENANT AND TENANT'S VENDOR FOR FINAL SIGN SPECIFICATIONS AND LOCATION. PARTIAL FIFTH AND ADJACENT SPACES FOR ACOUSTICAL PURPOSES. VERIFY 3 11 ALL ELECTRICAL ROUGH IN LOCATIONS WITH TENANT PRIOR TO 15. PROVIDE (5) /4 THICK ADJUSTABLE WHITE MELAMINE SHELVES ON DOUBLE SLOT STANDARDS AND FLOOR PLAN (1) NEMA " NEW NEMA 5-20R 20 AMP DEDICATED OUTLET BRACKETS. ASSUME STANDARDS AND BRACKETS TO BE SPACED AT 2'-0" INTERVALS. SHELVES TO BE ' WIRE PLACEMENT AND COVER. EQUALLY SPACED AT V-O" INTERVALS STARTING AT 1'-0" AFF. PROVIDE BLOCKING AS REQUIRED. REFER DIMENSIONED 5-20R 20NEW LIGHT SWITCH WITH OCCUPANCY SENSOR H. ALL ELECTRICAL AND MECHANICAL DEVICES AND COVERPLATES TO PLAN FOR DEPTH AND WIDTH DIMENSIONS. REFER TO DETAIL 1/A8.2 FOR ADDITIONAL INFORMATION. ELECTRICAL PLAN, AMP CIRCUIT SHALL BE WHITE. 16. PROVIDE SHELF AND ROD, REFER TO 6/A5.1. ENLARGED IT NEW LIGHT SWITCH WITH SLIDING DIMMER FOR NEW RECESSED CANS I. ALL ELECTRICAL/DATA/VOICE ON WALLS NOT BEING USED, PROVIDE AND INSTALL CORNER GUARDS, CG-1, ON ALL OUTSIDE CORNERS OF ALL VARYING DEGREE BEHIND BLANK PLATE OR IN A WALL TO BE DEMOLISHED ARE ANGLES, TYPICAL.17. EQUIPMENT PLAN TO BE REMOVED. WHERE ALL ELECTRICAL/DATA/VOICE BLANK 18 CONFIRM ALL EXTERIOR WINDOWS HAVE EXISTING BLINDS. REPAIR OR REPLACE ANY MISSING OR DAMAGED AND NOTES NEW PROJECTION SCREEN CONTROL SWITCH PLATES ARE REMOVED, WALL IS TO BE PATCHED, REPAIRED AND PREPPED TO RECEIVE NEW PAINT. BLINDS TO MATCH EXISTING AS REQUIRED. w NEW WINDOW COVERING CONTROL SWITCH J. FURNITURE IS SHOWN FOR SCHEMATIC PURPOSES ONLY. 19. PROVIDE AND INSTALL AUTOMATIC ROOM DARKENING ROLLER SHADES, WC-1, AT ALL CONFERENCE 507 DRAWN BY: LER > CR TENANT OR TENANTS VENDOR TO CONFIRM BUILT CONDITIONS WINDOWS. MUST BE INSTALLED WITH ABILITY TO CLOSE ALL TOGETHER OR CLOSE EACH WINDOW rY 4 CARD READER LOCATION FOR SPATIAL REQUIREMENTS AND FINAL LAYOUTS. INDIVIDUALLY. NEW ROLLER SHADE ENCLOSURE TO ALLOW EXISTING MINI-BLINDS TO REMAIN AND FUNCTION a3 ENLARGED PLAN 0 K. NO VOC PAINT SYSTEMS TO BE UTILIZED, TO INCLUDE PRIMERS INDEPENDENTLY. ROOM DARKENING ROLLER SHADES TO BE CONCEALED. REFER TO DETAIL 2/A8.2. CHECKED BY: SBH/PDK AS WELL A I FINISH PRODUCTS. 20. FURNITURE AND EQUIPMENT NIC. TYPICAL WHERE HALF TONED. TENANT OR TENANT'S FURNITURE VENDOR A�.i•� ® IT EQUIPMENT 521 1/4"=I'-O" ¢ KEY NOTE FOR REFERENCE L. ALL DIMENSIONS SHOWN AS PLUS/MINUS (f) ARE FOR TO CONFIRM BUILT CONDITIONS FOR SPATIAL REQUIREMENTS AND FINAL LAYOUT. SEE 4/A8.2 FOR SHEET: 4' GENERAL LAYOUT AND REFERENCE ONLY. VERIFY AND CONFIRM ADDITIONAL INFORMATION. ALL DIMENSIONS AND CONDITIONS PRIOR TO START OF WORK. 21. COORDINATE ALL WORKSTATION POWER AND DATA ROUGH-IN LOCATIONS AND REQUIREMENTS WITH TENANT NUM INTERIOR ELEVATION FOR REFERENCE NOTIFY ARCHITECT/ENGINEER OF ANY DISCREPANCIES PRIOR AND TENANT'S FURNITURE VENDOR. A21TO START OF WORK. 22. REFER TO APPLIANCE INFORMATION ON i/A5.1. M. ADD SOUND INSULATION IN ALL NEW WALLS, CONFIRM EXISTING 23. CONFIRM INSULATED SEAL EXISTS AT EXISTING COLUMN. IF NOT, PROVIDE NEW BUILDING STANDARD SooA DOOR NUMBER SYMBOL WALLS HAVE INSULATION. IF NOT, PROVIDE INSULATION. INSULATED SEAL. N. CONTRACTOR TO PROVIDE ALL CABLEAOW VOLTAGE CONDUIT. 24• CONFIRM FINAL NUMBER OF SWITCHES WITH DESIGN INTENT CONTACT TO ACCOMMODATE SEPARATE JOB NO. EXIT REQUIRED EXIT ALL CABLE/LOW VOLTAGE CONDUIT WORK COMPLETED BY SECTIONS OF WINDOW COVERING CONTROL. 2150954.15 EXPERIS CABLE VENDOR. 0. ALL VGA CONDUIT LOCATIONS MUST BE 1-1/2". PERMIT SET: 02/19/2016 215095415\4 DRAWINGS\ARCHITECTURAL\15_A2.1.DWG KJF 02/19/16 08:23 1:96.00 NOTE; A. FINISH ENDS, TYP D. ALL CABINET FACES AND DOORS, PL-2 H. MICROWAVE SHELF TO ACCOMMODATE 26"W X 20"D 19" U.N.O. D O 0 R S C H E D U L E B. CONFIRM CLEARANCE REQUIREMENTS AND E. ALL EXPOSED LAMINATE FOR UPPER AND LOWER X 14"H CLEAR OPENING FOR CONTRACTOR PROVIDED +----- SIZES FOR ALL EQUIPMENT/APPLIANCES CABINETRY TO BE PL-2. STAINLESS STEEL MICROWAVE (2) ADJ. WHITE DOOR DOOR DOOR DOOR FRAME HDWR DETAILS RATING COMMENTS AND REQUIRED CABINETRY DEPTHS WITH F. SHIM AS REQUIRED 1. PROVIDE (1) WATERLINE FOR CONTRACTOR PROVIDED MELAMINE SHELF OPENING SIZE THK TYPE MAT'L FINISH MA7'L FINISH GROUP STAINLESS STEEL REFRIGERATOR W/ ICE (1) 501A 3'-0"x8'--11"t -- GL GL -- ---- ---- 9/A&I H-4 20 MIN 1,5 TENANT, PRIOR TO CONSTRUCTION OF G. CONTRACTOR 70 PROVIDE DEDICATED OUTLET FOR � ' CABINETRY CONTRACTOR PROVIDED STAINLESS STEEL #GLDA696FSS WATERLINE FOR TENANT PROVIDED COUNTERTOP Ld 0 502A 3 -O x8 -8 f 1-XFL/R SC S HM P-2 8/A8.1 H-1 -- -- COFFEE MAKER AND (1) WATERLINE FOR TENANT I -' � �" --w P-LAM FACES 503A 3'-0"x$'-8"f 1FL/R SC S HM P-2 8/A8.1 H-2 2 C. ALL COUNTER TOPS, EDGES AND ADA DISHWASHER OR SIMILAR. MUST HAVE BOOSTER � _ BACKSPLASHES, PL-1 PROVIDED COUNTERTOP WATER COOLER. CONFIRM w - 504A 3'-0"x8'-8"f 1, " FL/R SC S HM P-2 8/A8.1 H-1 - _ HEATER & SANITIZING CYCLE. FINAL LOCATIONS & REQUIREMENTS WITH TENANT. -- 505A 3'-O"x8'-8"f 1 FG SC S HM P-2 7/A8.1 H-2 -- Architecture Interiors PROVIDE FASCIA BOARD ON UPPER SOBA 3'-0"x$'--$"f IX" FG SC S HM P-2 7/A8.1 H-3 -_ 1 Planning Engineering A5.1 A5.1A5.1 A5.1 A5.1 CABINETS TO HIDE CONTRACTOR 507A 3'-O"x8'-8"f 1-X" FL/R SC S HM P-2 8/A8.1 H-1 -- -- e. 3'-0" 6'-5"t 6'-i"f "-4" 8'-1"± 3'-2"f 3'-0" __ PROVIDED UNDER COUNTER LED 508A 3'-0"x8'-8"t 1�" FL/R SC S HM P-2 8/AS.i H-2 2 P.L. TOP (6) EQ. (6) EQ. (6) EQ. (3) EQ. LIGHTING FIXTURE -- > 31" 509A 3'-0"x8'-8"t 1�" FG SC S HM P-2 7jA8,1 H-3 1 LLJ SIDE SPLASH WHERE OCCURS 510A 3'-0"x8'-8"f 134" FL SC S HM P-2 7/A8.1 H-1 -- -- -N w 511A 3'-0"x$'--8"t IX" FL SC S HM P-2 7/A$.1 H-2 -- -- Portland,ON 515A '-0"x '- "f 1 " FL/R SC S HM P-2 8 A8 1 H-3 -- i 503.224.9560 _ ._. . . 3 8 8 00 00 P LAM COUNTER TOP AND /+4 ._ _. - ._. _. _- _ _. 1 _. n. ._. ____ .. .. ._ 516A 3 -0 x8 -8 f 1 FL/R SC S HM P-2 8/A8.1 H-2 -- 2 Vancouver,WA Wit , 4 F - -- -� SPLASH WITH SELF EDGE 517A 3'-O"x8'-8"f 1X" FL/R SC S HM P-2 8/A8.1 H-2 -- 2 360.695.7879 By MCI IMMOMUIRI __._ ___.___. _______._By am DRAWER AS OCCURS 518A 3'-O"x$'-8"f i-X" FL/R SC S HM P-2 8/A8.1 H-1 -- -- Seattle,WA �i °j �I E ucl I` I ( � IN ELEVATION 519A 3'-0"x8'-8"f 1�" FL/R SC S HM P-2 8/A8.1 H-3 20 MIN 1,3,6,7 206.749.9993 CNN (cep' a"w I _ _ I I � E www.mcknze.com a (1) ADJ WHITE MELAMINE SHELF 521A 3'--0"x8'-8"f 1 FL SC S HM P-2 7/A8.1 H-3 1,3,4 .._ Ld c I I w HARDWARE GROUPS, ABBREVIATIONS {REF fl 3-/A8. oNS} MACKENZIE. c� _ .._._.-- N REVIATIO ERT 2 FOR ELEVATI --- - H-1: PASSAGE 5'-2"f '-0" 3'- 4'-5"f ,_3„t w3'_0" N - LATCHSET F75 GRADE 1, FG IST FULL TGLAZED VISION PANEL ING ofslaN nelvfN ! CLIENT FOCUSED (6) EQ. (4) EQ. (3} EQ, 2) EQ. P-LAM BUTTS, SEAL, STOPS FL FLUSH Client i H-2: LOCKING DOOR 4" BACKSPLASH, OPEN BELOW VINYL BASE FL/R FLUSH WITH ADJACENT RELITE LOCKSET F82 GRADE 1, TYP. PER CODE INSULATE EXPOSED Y SEAL, STOPS HM HOLLOW METAL (CONFIRM GAUGE W/ TENANT) A. ELEVATION B. ELEVATION PIPES PER ADA CODE C, ELEVATION " o BUTTS, P PAINT 2 -6 3 3 H-3: CARD READER S STAIN, k !VOTE: ASSUME ARCHITECT TO REVIEW ALL CASEWORK SHOP DRAWINGS FOR DESIGN INTENT Y i LOCKSET F86 GRADE 1, BUTTS � � r-i**�CABINETMY ELEVATION 2 CABINET SECTION W SC SOLID CORE WOOD v ONLY. CLIENT TO PROVIDE FINAL REVIEW & APPROVAL OF ALL CASEWORK SHOP DRAWINGS. m UJ SEAL STOPS, ELECTRIC STRIKE, . " > "_ " N & REQUEST TO EXIT ON SIDE GL FULL BUTT GLAZED DOOR WITH ADJACENT BUTT �A5.1) 0 BREAK 513 AND WORK/COPY 514 1/4"=1 -0 w A5.i TYPICAL 3/4 -1 -0 Q WITHOUT CARD READER GLAZED RELITE H-4: NEW MAGLOCK W/ CARD READER ON DOOR SCHEDULE NOTES: 13" U.N.O. 13" U.N.O. 13" U.N.O. ENTRY SIDE & REQUEST TO EXIT ON A. ALL DOORS/CLOSURES TO BE CHECKED, (1) ADJ. WHITE _ TENANT SIDE. COMPLY W/ OSSC SECTION ADJUSTED, AND/OR REPLACED TO BE IN Project MELAMINE SHELF (2) ADJ. WHITE (2) ADJ. WHITE 1008.1.9.8 FOR ACCESS CONTROL EGRESS COMPLIANCE WITH ADA. EXPERTS iDOOR CONCEALED CLOSER PROVIDE DEADBOLT B. ALL TENANT ENTRY DOORS TO RECEIVE A MELAMINE SHELF i MELAMINE SHELF NEW DOOR WITH MORTISE LOCKSET AS SUE JOQ �? - l W/ THUMBTURN 0BOTTOM DOOR RAIL, DETERMINED BY LANDLORD, UNLESS NOTED Et�U�►NT w P-LAM FACE a P-LAM FACES UJ --' SIGNAGE ABOVE DOOR THESE DOORS SHALLOTHERWISE. IMPROVEMENT w w ! w P-LAM FACES REMAIN UNLOCKED DURING BUSINESS HOURS" C. ALL SECONDARY DOORS TO HAVE DEADBOLTS w -- PROVIDE FASCIA BOARD ON UPPER w - -= REMOVED, INSTALL COVERPLATES OR CHANGE I i MICROWAVE, NIC cn i cn DOORS AS AVAILABLE. LINCOLN TOWER CABINETS TO HIDE CONTRACTOR X. i .f PROVIDE FASCIA BOARD ON UPPER DOOR SCHEDULE COMMENTS: D. ALL DOORS AND FRAMES TO MATCH EXPERIS26t! 3W GREEBl1RG RD PROVIDED UNDER COUNTER LED CABINETS 70 HIDE CONTRACTOR 1. PROVIDE ELECTRIFIED HARDWARE AND KEY CARD ACCESS STANDARDS (DOOR FINISH MATCH KNOLL MAW, OREGON --- P-LAM UNDERSIDE AND LIGHTING FIXTURE INSIDE OPENING PROVIDED UNDER COUNTER LED SYSTEM. AUTUMN ON CHERRY FURNTIURE FINISH). > > SIDE SPLASH WHERE OCCURS LIGHTING FIXTURE 2. PROVIDE AND INSTALL COAT HOOKS AT OFFICE SIDE OF DOOR E. ALL NEW DOOR HARDWARE TO MATCH J 20" ELF .w,,, �► > 25" P.L. TOP (MATCH EXISTING BUILDING STANDARD OR H.B. IVES 582MB26 BUILDING STANDARDS. w SIDE SPLASH WHERE OCCURS w 25 U.N.O. NEW SINK & CONTROLS w SIDE SPLASH WHERE OCCURS WARDROBE HOOKS). COORDINATE INSTALLATION HEIGHT WITH F. VERIFY DOOR HEIGHT DIMENSIONS. ��� w 25" U.N.O. PER CODE {DOUBLE BASIN) w TENANT. AT DOOR 505A, INSTALL COAT HOOK ON WALL APPROXIMATE MEASUREMENTS BASED ON � w ,, 0 w BEHIND DOOR. CONFIRM FINAL LOCATION WITH TENANT. FIELD OBSERVATION. U G P-LAM COUNTER TOP AND N _.__�.__ P-LAM COUNTER TOP AND 3. PROVIDE CLOSER AT DOOR. SPLASH WITH SELF EDGE --- - P-LAM COUNTER TOP AND SPLASH WITH SELF EDGE 4. PROVIDE FULL HINGE AT DOOR. -- - - -- --- SPLASH WITH SELF EDGE -- - ---- -- 5. NEW BUILDING STANDARD FULL GLAZED DOOR W/ ADJACENT _--DRAWER AS OCCURS I - - --- -- - DRAWER AS OCCURS FULL GLAZED 3'--0" WIDE RELITE. DOOR AND RELITE TO POR D, IN ELEVATION _ �'� WRAP ALL EXPOSED PIPE IN ELEVATION OCCUR AT EXISTING ENTRY AND RELITE LOCATION. PROVIDE TEMPERED GLASS AT DOOR AND RELITE. PER CODE OF > i (1) ADJ WHITE MELAMINE SHELF = (1) ADJ WHITE MELAMINE SHELF 6. NEW SOLID CORE DOOR WITH ADJACENT FRAMED TEMPERED w I r 8" -J T- � GLASS RELITE. w _ - ' z �v P-LAM FACES w = ._ 7. PROVIDE SPLIT FINISH OF DOOR STAIN AND FRAME. CORRIDOR LU z w - j ,°,, SIDE OF DOOR AND FRAME TO MATCH EXISTING BUILDING MACKENZIE 2016 - e I _ w @ ALL RIGHTS RESERVED 1 cn a- CORRIDOR STANDARDS. I P-LAM f ''? to z P-LAM 4 THESE DRAWINGS ARE THE PROPERTY - - N C OF MACKENZIE AND ARE NOT TO BE t ( VINYL BASE 6" OPEN BELOW PER CODE i VINYL BASE I N I S H S C H E D U L E USED OR REPRODUCED IN ANY MANNER F R 0 0 M WITHOUT PRIOR WRITTEN PERMISSION ti TOE KICK AND VINYL C d FLOOR BASE N. WALL E. WALL S. WALL W. WALL CEILING 2'-0" 3 v 2'-0" BASE BEYOND 2'-0" 3 ca ROOM r CEILING REVISIONS: g w NO ROOM NAME MAT L MAT L MAT'L MAT'L MAT L MAT'L HT FINISH z CABINET SECTION CABINET SECTION 5 CABINET SECTION FINISH FINISH FINISH FINISH FINISH FINISH MAT'L COMMENTS o-J REVISIONS REVISION DELTA w W 501 RECEPTION CPT--1 VB-1 GB P-1 GB P-1 GB/P-1 GB/P-1 EXIST SAT W W THIS CLOSING DATE A&1 TYPICAL 3/4"=1'-0" ca A51 TYPICAL 3/4"=1'-0" ¢ ��f TYPICAL 3/4"=i'-0" M 502 INTERVIEW CPT-2 VB-1 P-1 GS/P-1 GB/P-1 P-1 EXIST SAT v v 503 OFFICE CPI-2 VB-1 P-1 P-1 GB/P-1 GB/P-1 EXIST SAT 504 WAR ROOM CPT-2 VB-1 WP-1 GB/P-1 GB/P-1 WP-1 EXIST SAT 2 F ; 505 IT OFFICE CPT--2 VB-1 P-1 P-1 P-1 GB/WP-1 EXIST SAT 2 506 IT OPEN OFFICE CPT-1 VB-1 GB/P-1 P-1 GB/P-1 GB/P-1 EXIST SAT CONTINUOUS MITE f SCHEDULE OF INTERIOR FINISHES 507 CONFERENCE CPT-2 VB-1 GB/P-1 GB/P-1 P-1 GB/P-1 EXIST SAT .+ + MELAMINE EDGE 508 OFFICE CPT-2 VB-1 GB/P-1 GB/P-1 GB/P-1 GB/P-1 EXIST SAT WHITE MELAMINE ON ALL °. 509 HALL CPT-1/VCT-1 VB-1 GB/P-1 GB/P-1 GB/P-1 GB/P-1 EXIST SAT 1 EXPOSED SURFACES, z: NOTE: FINISH SUBMITTALS TO BE REVIEWED AND APPROVED BY TENANT. 510 CLOSET CPT-1 VB-1 GB/P-1 GB/P-1 GB/P-1 GBIP-11 EXIST SAT STEEL HANGRAIL ;� 511 STORAGE CPT-1 VB-1 GB/P-1 GB/P-1 GB/P-1 GB/P-1 EXIST SAT CPT-1: SHAW, COLLECTION: MIX IT UP, STYLE. ECLECTIC 5A164, COLOR: TORTOISESHELL 64740, 512 WAITING CPT-1 VB-1 P-i GB/P-1 GB/P-1 GB/P-1 EXIST SAT - FOR ORDERING REFER TO CORPORATE CARPET CONTACT INFORMATION ON TIA 513 BREAK VCT-1 VB-1 GB/P-1 GB/P-1 GB/P-1 GB/P-1 EXIST SAT 1 SHEET TITLE: = CPT-2: SHAW, COLLECTION: MIX IT UP, STYLE: MELD 5A165, COLOR: TORTOISESHELL 64740, FOR 514 WORK/COPY VCT-1 VB-1 P-1 GB/P-1 GB/P-1 GB/P-1 EXIST SAT CABINETRY leftORDERING REFER TO CORPORATE CARPET CONTACT INFORMATION ON T1.1 5i5 OPEN OFFICE CPT-1 VS-1 GB/P-1 GB/P-1 P-i GB/P-1 EXIST SAT ELEVATIONS, 516 OFFICE CPT-2 VB-1 GB/WP-1 GB/P-1 I P-1 P-1 EXIST SAT 2 DETAILS AND VCT-1: MANNINGTON COMMERCIAL, TOUCHSTONE PREMIUM, COLOR: 9143 FLAX, SIZE: 12"X12" 517 OFFICE CPT-2 VB-1 GB/P-1 GB/P-1 GB/P-1 P-1 EXIST SAT SCHEDULES io VTS-1: JOHNSONITE TRANSITION/ADAPTORS TO BE THIN PROFILE, COLOR: MATCH JOHNSONITE 47 518 CONFERENCE CPT-2 VB-1 P-1 GB/P-1 GB/P-1 P-1 EXIST SAT 519 HALL CPT-1 VB-1 GB/P-1 GB/P-1 P-1 GB/P-1 EXIST SAT c BROWN w 520 OFFICE CPT-2 VB-1 GB/P-1 GB/P-1 GB/P-1 GB/P-1 EXIST SAT VS-1: JOHNSONITE, COLOR: 47 BROWN, 4" COVE THROUGHOUT 521 IT EQUIPMENT VCT-1 VB-1 GB/P-1 GB/P-1 GB/P-1 GB/P-1EXI T SAT 1 PL-1: PIONITE, MINERAL TALC AG383 SUEDE FINISH SCHEDULE NOTES: ABBREVIATIONS: 11/2" WOOD BLOCKING A. PATCH AND REPAIR ALL EXISTING WALLS WHERE CPT CARPET DRAWN BY: LER PL-2: PIONITE, CRESSIDA AT371 SUEDE AFFECTED BY NEW WORK. PROVIDE PRIMER PAINT EXIST EXISTING 5 18 1/2 THROUGHOUT AS REQUIRED TO FULLY COVER EXISTING GB GYPSUM BOARD CHECKED BY: SBH/PDK P-1: BENJAMIN MOORE HC-82 BENNINGTON GRAY, EGGSHELL FINISH AT WALLS AC(FNT PAINT. PAINT NEW AND EXISTING WALLS. P PAINT ,�. PROVIDE NEW FLOOR FINISH AND RUBBER BASE VB VINYL BASE SHEET: END & INTERMEDIATE d -j P-2: BENJAMIN MOORE HC-82 BENNINGTON GRAY, SEMIGLOSS FINISH AT ALL DOOR AND RELITE THROUGHOUT. BRACKETS - SPACE TO FRAMES VCT VINYL COMPOSITION TILE ALLOW MAX. 36" SPAN. FINISH SCHEDULE COMMENTS: VTS VINYL TRANSITION STRIP 4'-O"H AFF 3/4" PART. BD. - ANCHOR CG-1: IPC, SIZE: 2"x2", COLOR: CHINO, TO RUN FROM TOP OF VINYL BASE TO -Y4 HEIGHT OF THE 1. PROVIDE VTS-1 WHERE VCT MEETS CARPET. WB WHITESOARD PAINT A5,1 TO ENDWALLS OF CLOSET WALL ON ALL EXTERIOR CORNERS, INSTALL WITH SCREWS SAT SUSPENDED ACOUSTICAL TILE 2. REFER TO 1/A.2 FOR WP-1 LOCATIONS, INDICATED BRUSHED CHROME ROD WC-1: MECHOSHADES, BY -. ALL WALLS SHOULD BE PREPPED AND EQUINOX BLACKOUT 0100 SERIES (OPAQUE}, COLOR: TBD, MUST BE CONCEALED, ! - i CONFIRM FINAL SPECIFICATIONS WITH TENANT CLEANED PER MANUFACTURER'S SPECIFICATIONS, JOB NO. PRIOR TO APPLICATION. 6 COAT CLOSET SHELF AND ROD 21509 .1 F... WP-1: IDEAPAINT CREATE IN WHITE, (LEVEL 5 FINISH REQUIRED AT WALL PRIOR TO APPLICATION) p A5� 3"=I'-O" a PRIMER: IDEAPAINT IN WHITE PERMIT SET= 02/19/2016 0 215095415\4_DRAWINGS\ARCHITECTURAL\15_A5.1.DWG KJF 02/19/16 08:24 yf.01 yr r4 ;i ,I - I t Li• , , I t _-_J_..--., I uuiI • , , , , , r ,, .M;rr.kTI[ ^ FS ____ Architecture_I____ ' . - - ----- - Planning Engineering -____ ------ _ ___ _____ ..aawawaA ,..__ + • , t t , t „ • r t r-----r_____r_---- f r_____t_____ i....: r_____,___ • , , , , a , Portland,OR t ..._....., _ _. , . _ _ ,.... ___. ... � . . 503 224 9560 14 r..._.;.-----i----- ----. }___._�__.__ _____}_____}__________________i_____;_____ ._.__�_.___1____{_____, ', / f Vancouver,W tJ' �) ' (a C , Vancouv A ' „ , EQ 360.695.7879 _ t a_ _ _ _ I tom`.• ' ^ , I I , I I < r I .... le, WA v__a.�_a_ .t,. _ I I Y_ Y._.._ 206.749.9993 Seatt I I I r i ..... ...........J. www.mcknze.com ' I ; o ® 0 7 cknae.com ----------------- ----- ----- ---- - ------------ -- -- -- i" a ; , I , I , I • I I , I V7 ,. I ` _ Y . i, 4 t , • i , ,.."� ,. ., ,. t,- _. -„r,-._._.,___._.,_____�_____r-'-";”—','__'__• ------------ya.a.,',aaaac{._____� }>..: i_"__'- i_..._'.;.._ ACKEN � 1 t ----- DESIGN OgIVEN 1 CLIENT FOCUSED t ' • , ,.i ' s' ♦'� I •�.} ; MIS' . 8 FS j Client , I , , t I I : i r [ t , I ' ; , • t , r , • t v. ,,,.- x t t ..;.,:, • • " 'fit 9 m£ s, s. s s, is s , , v. • t , , , .1 , I t ♦ t t ' t r , ..++,•..... Y r w' , as _ _ _.._. .... t . .. _-__. .,a... _..___ _____ __._. t. ......:r ......4... ..•h___ ._ __ _ __ `____--___� fes' j, l } i i G""""'-`•� Y �+^^^^•r-----,___•_Y_•_••------------4 of _ _} aY• - _ __ _ T t•T' J a f y, +hY/ Jr • ; , t ' : : �i t t ' t t , t t t f , ' t , ; , I , , t , [ t , � • , e t t , + , , t , t t t t r t a t , e [ • r- , t , . t r a t ' t -v , , Y Y r , + r -.- r , r r , , -' } _ _ _ __y„a� ..... t r • f f • , • , i 1,n, t t , { �, � < t • t t e , , , }[, , , • i ; ; t t , , i+ t t t : , i 1 / i } `, , t , , i i S i"• j t , , , t , t t t t i F , , t ♦ • , t a • , ; ' / $ ,T al i -uan+�wvvi� i! S •3: q:. ♦ , -- t ^. , t . t . , , t • ' , t e t , , t t t : ,`Ir ."a a .,. `s>.r , , , t ♦ , : t , , , s t , ♦ �aaaa� r e e , , - ' • i ..yaaaaWaaa« . � . -. ... �:.v ____ _____ ____ J.aaaa ' 3..._.t_____' . r t t t , , , t' "Y • t , t i 1 , , t t ±.,, y ,,'` t r , 1� t ,-t x.'a�,rr'v�I,t_ ..}.,,•v �-_____i_ -fiaaaa '�_____t_____ti�awu�.aaaa�_.__.i_.-__ __f_ {M , ••,S<a' + int'' i 1`(- l i i`f' I �•f' I ,"i`f-' F �'! {{ ,! !` f � ,,% F f r fw f T r t , t . , t •`, t t , t , ' r t . � I' t t t ` r , `r �r , Q 4 r �*•� t • , r , - , t , • ------I.._ _- ..a.,aaaa.•1_....... ' .,.aa.aA__ __}_____, + 4:x ' S:x.:,f...:YC__._.i__.-__�_ ' awa� s • , .; +.. ; � , „ t ; < / /. .... -------------------- 4 -- SJ, , : ; : : ; t: .+$ ''r' i t'- A r , t , r , I , ; r • , I --r I , I : r , I r • • , .___Y ____�..w.,..y....,,..,.{ Y r r , -r .._-r .,__ -Y_ __�_ __•__ _,_-----------__ ,-_.__.y-.....,.y..._..•__ _,_. _ _ _ _ _ - _ _ _- -y--:-, • • . . I , I , , , I , , I , [ , , , I I I I I „ , I • h ,n I I I <. i « 4 - — ----- •----- _____.,. ,y,` Yi 'y„r,., -..�+',.�..y,,,'r_ r., ,.,o .t , I I • r I , 1 t , , , I , • , , I tl ' � M I , , 1 Y -=-z ., �__ O O O _ I t ' , , `.' ,� , • 'I , " " , , I , .may, I t I , • • , , I I I t ; ; I ; r ^, I _ __ EXPERTS , I _____ 5.:.•:'...1 _____ __.__'.____'___... Sraa'a«aai .._..'_____ _____ ______4Se+< .•.::`al____.J-----_l__._.'_ . _. _. ............ __ __ __ _L_._._i-----'.............. _ .. .. .... r I : I t r I I �; _____________ ------ ----- --- ------ -- ----- -- - I ' I , I I I � SUITE 500 y i �:....}....tiTENANT -----------Jr...........:«. t i - ` ac `^". d__._..._..-r- . .. .. R—�^^; i `---------- Fs; O IMPROVEMENT Ea , > + ,, • r ' , ____Sb== ,••N_____' t:••• s••e1'__.._' '__.'------ '.�... '• ------------------------.•_____i.�._..1_____J_____J-_____4_.___4___._'.__'-'____-i_____3_____i_____�_____a__�>.__.»_ �.____«�.__- J-____J______�__'_'}-_-__i_____:______�____.i____. -._�__ , : 2 3 __--�_____ ,a„a,�',,,,,,•�� '------ _.._..,.-_._..•�.�,._____' ---__i_____ar _ _. _ . _ __-- ,,ay',.aa p,'_____i__..__ _____r_____Y .:j.....' ____}____.tl. ' _. _. ' .>: ' ____ _ _ _ ___ ___ ___ _ ��/)/��rR %, •` .^' .r.. ..J,.0 r ..,...:Y' ",R, ter...�• aaiaa t '�•.�I. 7D VYPI f -� a UNC:OUV TO t _ .. .. - .. -- . - __ __ _ _. as -- as 10281} SW GiREEi�IAURG RQ _ •- ' -- - - - - - as as - -- - __ e t t t t t t C?��EM '' • • a� __r _ �.a'asyaa`aV,._ _.j.. _.�ri'xi{x rn�__ .�i��'a.�va s+� ,ia'v� 'wa�.- ice_ t t , , t , • a , [ t , , -----L-----1-----i,----.4...___t-__-_a.._._J--_---'-----r---__a-----,-_---.,.._._.,. ___ __ _ __ -----------------_____ ____ _____ _____ _____ ____ _ __ ____ _ __» .. .-_ -_ _ ift t � t r • -�„aaaaaj..asn+y--•_..-_ ..-.�.._. -�_ -__ ....Y.. _- _____ •------ -. _ _ -- .- 1 ---- - ---- ---- --- ..Jr. __-- -_. - .y..... -•-_4__...t<„ ,.yt_____4_____l.____3______f tJ '( i` ,, •I �•�_ " ��• `z.wa,}.waa�_ 4 _4_ .�a. ..�.i .,•�w ..�.w. „�. i J, fw t ^, i t ,, Y . "------ks...�f....r� 1':....x.>A - �`�a..`aaa.:. f aaaa.aa..2- —h - ,mss. p .�f - ; F i`�aaayva.aaa }- .{::.>.�aa.ti:i -�s:..aya.a:�f - �:..>.f.::r < 0 0 `"+�E LE , . . . . . . t ' r - -r —r m"__ -J-mm . S G K",� DEMO REFLECTED CEILING PLANri� REFLECTED CEILING PLAN • Poor , ORL �AW) 1/8"=1,-0" A6.1 1/8"=1'-0" 9+ OF GENERAL NOTES LEGEND MACKENZIE 2016 A. SUSPENDED ACOUSTICAL TILE CEILINGS AT 8'-11"± (EXISTING) AFF, UNLESS NOTED OTHERWISE. EXISTING CEILING GRID AND TILE © ALL RIGHTS RESERVED B. FOR SEISMIC BRACING OF SUSPENDED CEILING AND INTERSTITIAL EQUIPMENT SEE DETAIL 1/A8.1. THESE DRAWINGS ARE THE PROPERTY C. CENTER ALL DOWN LIGHTS, FIRE SPRINKLER HEADS, SMOKE DETECTORS AND ALL OTHER CEILING PENETRATIONS IN CENTER OF MACKENZIE AND ARE NOT TO BE OF 2x2 TILE, UNLESS NOTED OTHERWISE. USED OR REPRODUCED IN ANY MANNEF D. COORDINATE ELECTRICAL REQUIREMENTS WITH TENANT, ALL ELECTRICAL DRAWINGS WILL BE BY DEFERRED SUBMITTAL. { EXISTING CEILING GRID AND TILE TO BE DEMOLISHED WITHOUT PRIOR WRITTEN PERMISSION E. HVAC CONTRACTOR TO PROVIDE FULL SHEET OF THE FLOOR AFFECTED UPON COMPLETION. CONTRACTOR IS RESPONSIBLE REVISIONS: TO PROGRAM THE OVERRIDE HVAC BUTTON. NEW CEILING GRID AND TILE MATCH EXISTING F. LIGHTING LAYOUT IS SHOWN FOR PRELIMINARY DESIGN INTENT ONLY. FINAL LIGHTING LAYOUT TO BE PROVIDED BY THE oQ REVISIONS REVISION DELTA ELECTRICAL CONTRACTOR AND IS DEPENDANT ON OREGON ENERGY CODE ALLOWANCES AND EXISTING BUILDING >'I THIS CLOSING DATE INFRASTRUCTURE IN CEILING. ELECTRICAL CONTRACTOR TO REVIEW ALL REQUIRED LIGHTING LEVELS AND DISTRIBUTION ® Ww SHEET AND NOTIFY ARCHITECT OF ANY CONCERNS OF FOOTCANDLES WITHIN ANY AREA OF THE SPACE. NEW OR RELOCATED BUILDING STANDARD 2'x4' FLUORESCENT LIGHT FIXTURE G. G. PROVIDE FINAL HVAC PLACEMENT/ZONING DIAGRAM FOR DESIGN INTENT CONTACT REVIEW AND APPROVAL PRIOR TO FINAL �.- HVAC INSTALLATION. rDEMOLISHED 2'X4' FLUORESCENT LIGHT FIXTURE TO BE RELOCATED H. PROVIDE FINAL SWITCHING/LIGHTING PLACEMENT/ZONE MAP FOR DESIGN INTENT CONTACT REVIEW AND APPROVAL PRIOR "------ -"J TO FINAL SWITCHING/LIGHTING INSTALLATION. ASSUME UP TO (3) LIGHTING ZONES PER CONFERENCE ROOM. 0 NEW FLUORESCENT RECESSED CAN LIGHT ' I. REPLACE DAMAGED AND SOILED CEILING TILES TO "LIKE NEW" CONDITION THROUGHOUT AND WHERE AFFECTED BY CONSTRUCTION TO MATCH EXISTING. c NEW RECESSED MR16 DIRECTIONAL CAN LIGHT (HALO, MODEL # 2450 J. AT ALL SUPPLY DUCT PENETRATIONS OF WALLS TO STRUCTURE, PROVIDE ACOUSTIC SEALANT AT GYP BOARD AND 26 ADJUSTABLE SLOT APERTURE, 30 DEGREE TILT, WHITE FINISH) GAUGE SHEET METAL CLOSURE COLLAR W/ SEALANT TO DUCT, PLENNUM AND WALL. AT ALL RETURN AIR PENETRATIONS THROUGH WALLS TO STRUCTURE, SEAL AS NOTED FOR SUPPLY DUCTS OR PROVIDE "U" SOUND BOOT FOR UNDUCTED EXISTING SUPPLY/RETURN VENT TO REMOVED/RELOCATED RETURN AIR, K. ALL ROOMS TO HAVE SUPPLY/RETURN. SHEET TITLE: L. ALL CONFERENCE ROOMS TO HAVE SEPARATE HVAC CONTROLS FROM GENERAL OFFICE. FS EXISTING FIRE STROBE TO BE REMOVED/RELOCATED DEMO REFLECTED KEYNOTES EXISTING EXIT SIGN TO BE REMOVED/RELOCATED CEILING PLAN, 1. PROVIDE DATA/ROUGH IN LOCATION AT CEILING. COORDINATE FINAL LOCATION WITH EXPERIS TECHNOLOGY COORDINATOR NEW EXIT SIGN — DESIGN BUILDER TO PROVIDE DEFERRED SUBMITTAL REFLECTED CEILING PLAN AS LISTED ON T1.1. EXISTING SPRINKLER HEAD TO BE REMOVED/RELOCATED AND NOTES 2. PROVIDE AND INSTALL CEILING RECESSED MOTORIZED PROJECTION SCREEN AND NECESSARY TRIM KIT (DA—LIGHT COSMOPOLITAN ELECTROL, SIZE: 120"W x 96"H). PROVIDE BRACING AND ELECTRICAL AS REQUIRED. COORDINATE FINAL A NEW VOICE/DATA ROUGH IN LOCATION AT CEILING LOCATION WITH EXPERIS TECHNOLOGY COORDINATOR AS LISTED ON TIA. 3. PROVIDE BRACING AND ELECTRICAL AS REQUIRED TO ACCOMMODATE TENANT PROVIDED CEILING MOUNTED PROJECTOR. NEW OUTLET AT CEILING INSTALL TENANT PROVIDED PROJECTOR BRACKET AS REQUIRED. COORDINATE FINAL LOCATION WITH EXPERTS TECHNOLOGY COORDINATOR AS LISTED ON T1.1. PROVIDE 1-1/2" CONDUIT FOR VGA RUN TO CONNECT TO FLOOR MONUMENT. CONFIRM NEW RECESSED PROJECTION SCREEN DRAWN BY: LER FINAL LOCATION AND REQUIREMENT WITH TENANT. ASSUME PROJECTOR TO BE CENTERED WITH CENTER OF PROJECTION SCREEN. CHECKED BY: SBH PDK 4. PROVIDE SEPARATE 1-1.5 TON LIBERT SUPPLEMENTAL COOLING UNIT (TO PROVIDE MINIMUM 24,000 BTU, 24 HOURS A PROPOSED EGRESS LIGHTING PATH DAY, 365 DAYS A YEAR). UNIT TO BE LOCATED OUTSIDE OF THE ROOM AND DUCTED INTO THE ROOM. MECHANICAL SHEET: CONTRACTOR TO PROVIDE EXPERIS' PROJECT MANAGER A PROPOSAL FOR MAINTENANCE ON SUPPLEMENTAL COOLING UNIT. — — + — UNDER CABINET LIGHTING 5. PROVIDE AND INSTALL WHITE NOISE/SOUND MASKING (LENCORE) THROUGHOUT THE ENTIRE SUITE. COORDINATE FINAL LOCATIONS OF CONTROL KNOBS AND SPEAKERS WITH TENANT. CONTRACTOR TO CONFIRM IF LOCATED WITHIN IT — — --- NEW MECHOSHADE, SEE DETAIL 2/A8.2 A61 EQUIPMENT ROOM. IF SO, COORDINATE FINAL LOCATION WITH TENANT. 6. EXTEND CORRIDOR CEILING GRID AND TILE AS REQUIRED AT CORRIDOR EXTENSION TO ALIGN WITH EXISTING. MATCH BUILDING STANDARD CORRIDOR FINISHES. 7. PROVIDE NEW 2x2 BUILDING STANDARD CEILING GRID AND TILE THROUGHOUT SUITE. CENTER GRID AND TILE WITHIN JOB NO. ROOM, UNLESS NOTED OTHERWISE ON 2/A6.1. ADJUST ALL PENETRATIONS PER GENERAL NOTE "C." 2150954.15 8. NEW UNDER CABINET LIGHTING. REFER TO 2,3,4,5/A5.1 FOR ADDITIONAL INFORMATION. 9. CONFIRM NEW LIGHT PLACEMENT DOES NOT INTERFERE WITH EXISTING WALL. RELOCATE LIGHT IF REQUIRED. PERMIT SET: 02/19/2016 215095415\4—DRAWINGS\ARCHITECTURAL\15_A6.1,DWG KJF 02/19/16 08:24 1:96.00 FLOOR OR ROOF STRUCTURE POP RIVET RUNNER TO 7/8- WALL ANGLE AT 2 LINCOLN TOWER STUD SIZE: 3-5/8" AT WALLS INDICATED ONE HOUR RATED ON PLANS BERC 2 8" MAX. PROVIDE UL DESIGN #0465 INCLUDING: FIRE SAFING AT RATED ADJACENT WALLS, FASTEN CLOSURE ANGLE WITH #6 CLIP WALLS BETWEEN FLUTES, SCREWS DIRECTLY TO WALL FRAMING OR PROVIDE STRUT NO FIRE SAFING REQUIRED STABILIZER BAR BETWEEN ALL MEMBERS AT PERIMETER LIMITING WALL HEIGHT TABLE AT DEMISING, NON-RATED WALLS ADDITIONAL #12 WIRE SUPPORT AT ALL MEMBERS NTEFMR NON SERI TUT NON-CMAPOSME WALLS L/240 0 5psf < WITHIN 8" OF PERIMETER DEFLECTION HEAD W/ DEFLECTION SPACE %0 DESKM110N SPACE MAX. WALL HE304T 11E4 WD LATERAL BRACING WITH APPROVED VERTICAL 1(`DD NOT FASTEN STUDS COMPRESSION STRUT AT 12'-0" OC EA WAY 8"+F 250SI25-18 24" 8P-4" 1. 7< I MIN OR GYP BD TO RUNNER) Architecture w Interiors COUNTERSLOPE HANGERS IF MORE THAN 1:6 OUT OF PLUMS CONT 18 GA METAL E 2505I25-18 16" 9P-7" FASTENED TO DECK 0 2'-0- Planning Engineering "ATTACHED 01 2505I25-27 24" 9'-10" METAL DECK OC STAGGERED WALL" Q AS OCCURS 1 MIN FIREDAM SPRAY TYP, 2505I25-18 16" 11'-3" EACH SIDE OF TRACK OR 362SI25-18 24" 13#-5" FASTEN RUNNER TO FIRE SAFING SEALANT TYP -'\C SOUND ATTENUATION INSULATION A -ELM EDW AT WAIL NTS 0 2'-0" OC 362S125-18 16" 14'-4" Portland,OR "��N�OTE. FOR UNATTACHED WALLS PROVIDE A 112" 503.224,9560 - - - - - - - - - - TO 3/4- GAP BETWEEN EDGE OF ANGLE AND CLIP 3625I62-33 16" 16'-5" 5/8" TYPE 'X' GYP. BD. EA. SIDE DO NOT SCREW BERC 2 CLIP TO TRACK METAL STUDS, SEE WALL ATTACH WITH IN LONG TYPE S SCREWS Vancouver,WA LSLI 362SI62-43 16" 18P-O" SPACED 8" OC ALONG EDGES AND 12" 360.695.7879 ,E TABLE MAX. LENGTH 600SI62-33 16- 24'-6- HEIGHT TABLE FOR GAUGE OC IN THE FIELD OF THE BOARD. Seattle,WA CROSS RUNNERS FIT BETWEEN MAIN RUNNERS 112- DIA CONDUIT EMT) 5'-10" i AND SPACING JOINT TAPE AND COMPOUND 2 COATS 206.749-9993 MAIN RUNNERS AT 4'-0" OC IN71ER11011 NON STRLCTLIRAL NON-COMPCOM WALLS TO JOINTS AND SCREW HEADS) www.mcknze.com 6'-0" MAX SUPPORT WITH #12 WIRE AT 4'-0- OC OR I DIA CONDUIT (EMT) go-gor BOTTOM TRACK TO FINISH FLOOR DIA CONDUIT 044T) 7F-8p# W17H CERAIMC TILE FACING L/360 ® 5 psf WITH #10 WIRE AT 5'-0" OC EA WAY SGL 1625I25-33 MTL STUD 12'-0" WITH POWDER DRIVEN ANCHORS MACKENZIE, LATERALLY BRACE MAIN RUNNER TO (1-518"x20GA) DESIGNATIONSPACING MAX- WALL HEJG-ff AT 4'-0" O.C. NO SEALANT DESIGN PROVEN I CLIENT FOCUSED cn A T SIM COND NOTE: STRUCTURE AT 12'-0" OC EA WAY. BACK TO BACK 162SI25-33 15'-0" 362SI25-18 16" 12'-4" — ALL GRID MEMBERS AND BEGIN BRACING WITHIN 6'-0" OF MTL STUDS (1-5/0"x20GA) 362SI25-33 16" 14'-3" CONT ACOUSTIC SEALANT Client SGL 250SI25-33 MTL STUD 139-6" _J CONNECTION DEVICES TO BE OF AN PERIMETER AND 2" FROM CROSS MEMBER LU I I I EACH SIDE AGAINST TRACK ]i m APPROVED TYPE AND HAVE A 180# IN AREAS GREATER THAN 1,000 SF (2-112"x2OGA) < CAPACITY. ALL LATERAL BRACING SECURE ALL HANGERS TO BLDGWALL TABLES ARE BASED ON WALLS SHEATHED BOTH SIDES FULL HEIGHT WITH BACK TO BACK 2505I25-331 15'-0" CONCRETE SLAB STRUCTURE. TRAPEZE DUCT WORK 112- - "GYPSUM BOARD ATTACHED WITH #6 SCREWS MIN. AT 12 -0O.C. MAX WIRES TO HAVE A 200# CAPACITY. MTL STUDS (2-112 x20GA) AND OTHER LARGE OBSTRUCTIONS 2 1—HOURT�SUSPENDED CEILING BRACING z �WALL HEIGHT TABLE r3"*� WALL 3 r . 4. s ruJ r NOTE: PROVIDE SEISMIC SEPARATION JOINTS IN CEILINGS GREATER NTS TO STRUCTURE 3"=1'-0" ��8.1 z �A&1) '\�8_1 THAN 2,500 SF. PROVIDE HEAVY DUTY GRID SYSTEM. i 0 Project EXPERIS ATTACH STUD TRACK A SUITE WALL AS OCCURS WO THROUGH GRID TO GYP BD PARTITION SEE PLAN TENANT BRACE ABOVE SOUND ATTENUATION BATT IMPROVEMENT SUSPENDED CLG AT ALL WALLS, TYP. SOUND ATTENUATION BATT SOUND BATT AS OCCURS ASSEMBLY AS OCCURS GYP BD LINCOLN TOWER A Z LINE OF SILL AS OCCURS GYP BD WALL AS OCCURS 10260 SW GREENBURG RD 45* TIGAW, OREGON I x IV V maim CUT TILE FOR TIGHT METAL STUD BRACING ALUMINUM TRIM PIECE "CEE" OD TO FLOOR STRUCTURE A T 8 -0" FIT AT WALLS W1 1)6- RETURNS, FINISH 4j E CASING BEAD OC W1 (2) #8 SHEET METAL TO MATCH WINDOW FRAMES DOUBLE STUD AT JAMB, TYP A 318 RESILIENT CHANNEL SCREWS AT EACH END. STUD SIZING L I PAINTED DOOR FRAME 0 24" O.C. HORIZONTAL USG 200-A (ANODIZED BUILDING EXISTING DEMSING, PER SPAN TABLE. BRACING TO BE STANDARD) -HR SOUND ATTENUATION ,­`� PROVIDED WHERE DISTANCE BETWEEN 1-HR, OR 2 PAINTED DOOR FRAME WALL AS OCCURS5/8 GYP BOARD AT ALL NEW WALLS, TYP. PERPENDICULAR INTERSECTING WALLS PORT D, 0 OR HORIZONTAL BRACING BETWEEN NEOPRENE SEAL WALLS EXCEEDS 8'-0" OC OF jil", METAL STUDS SEE WALL HEIGHT GYP BD EA SIDE 'NL TABLE FOR GAUGE AND SPACING y CONT ACOUSTIC SEALANT STOREFRONT GLAZING MACKENZIE 2016 -- SIDE LIGHT AS OCCURS @ All RIGHTS RESERVED EA SIDE AGAINST TRACK SYSTEM NO SEALANT AT SIM COND WITH 1/4" TEMP CLASS THESE DRAWINGS ARE THE PROPERTY 112- MAX& OF MACKENZIE AND ARE NOT TC BE 1p USED OR REPRODUCED IN ANY MANNEF EE BOTTOM TRACK TO FINISH WITHOUT PRIOR WRITTEN PERMISSION --------- CONCRETE SLAB FLOOR W1 POWDER DRIVEN QREVISIONS: =3 ANCHORS AT 4"'-0" OC z �TY z wWREVISIONS REVISION DELTA EXIS*TING WALL 5 *�NNON-BEARING WALL z r6%�WALL r7 NTYP INTERIOR DOOR r8 P INTERIOR DOOR 1 THIS CLOSING DATE I J I I w SHEET 3'v=l'-O' _J �A&1) AT FLOOR AND SUSPENDED CEILING 3"=1 0" �3 A&1) 0 EXTERIOR MULLION 3"= 0" A8.1 HEAD SIMILAR 3"=1#-O" A8.1 JAMB SIMILAR 3"=1*-0" 0 NEW BASE TO SOUND ATTENUATION BATT MATCH EXISTING AS OCCURS NEW VINYL BASE 4'-8" 1/4" TO RECEIVE VINYL PLYWOOD WALLBOARD ENTIRE LENGTH BASE COVE OF WALL EQ. EXPERIS EQ. 10 SIGNAGE t (0 BLOCKING SHEET TITLE: 4- CLEAR SILICONE SEAL = C4 DETAILS AND AT PERIMETER, TYP. -1 0 ELEVATIONS2 I VI 0 -----,-­—GROUND BAR - SEE NOTE #2 c0 (0 BASE AT JAMB 1/4- TEMP BUTT GLAZED FLUSH WITH GYP BD; ADJACENT RELITE F-L.—SINGLE NEMA 5-20R - SEE NOTE #1 PROVIDE "J" MOLD AT —FULL GLAZED DOOR TOP OF BASE FOR (1) 120 / 20AMP FOR SECURITY - SEE NOTE #3 NOTES: GYP AND KNIFE EDGE MILLWORK BLOCKING -CONTRACTOR TO INSTALL EXPERIS REVEAL RAIL OF FULL SIGNAGE 5' AFF AND CENTERED WITHIN GLAZED DOOR TELEPHONE/SERVER ROOM NOTES: GENERAL CONTRACTOR IS RESPONSIBLE FOR ADDING WALL IN SHARED RECEPTION 501. BUILDING STANDARD 1. INSTALL (1) 20 AMP CIRCUIT CENTERED UNDER THE PLYWOOD BOARD. BLOCKING BEHIND ALL MILLWORK, WALLMOUNT TV'S, SMART BOARDS ETC. -ELEVATION NOT TO SCALE. DRAWN BY: LER NEW BASE TO 41, DOOR HARDWARE SEE PLAN FOR CORRECT LOCATION. (I SEPARATELY FUSED CIRCUIT THAT REQUIRES BLOCKING MATCH EXISTING FOR SINGLE NEMA 5-20R OUTLET. *COORDINATE FINAL BLOCKING LOCATION AND REQUIREMENTS FOR TENANT CHECKED BY: SBH/PDK 1/4- TO RECEIVE VINYL 2. INSTALL (1) BUILDING GROUND CIRCUIT FOR THE TELEPHONE SYSTEM PROVIDED WHITE BOARDS AT CONFERENCE 507 AND 518. GENERAL CONTRACTOR TO HANG EXPERIS SIGNAGE. BASE COVE CENTERED UNDER THE PLYWOOD BOARD. FURNITURE BLOCKING - STEP 1: TAKE MEASUREMENTS TO FIT SIGN APPROPRIATELY ON THE WALL AREA. SHEET: 3. INSTALL (1) DEDICATED 120 / 20AMP FOR SECURITY (CENTERED, LEFT, JUSTIFIED, ETC.) NEW VINYL BASE 4. REFERENCE SHEET A2.1 FOR LOCATION OF IT EQUIPMENT RACK AND 2 TYPICAL BLOCKING - OFFICES 503, 508, 517, 520 - STEP 2: SET PAPER PATTERN ON WALL ACCORDINGLY AND LEVEL. DEDICATED 120V / 20 AMP QUADS. - STEP 3: DRILL 6-1/4"HOLES IN WALL SURFACE (MINIMUM 2"DEEP) RUN BLOCKING FROM BACK WALL/END OF WALL FORWARD 60- & FROM 42- AFF TO 72" AFF - STEP 4: SCREW IN MOUNTING STUDS INTO BACK SIDE OF SIGN. A8,1 - STEP 5: REMOVE BLUE MASKING ON TAPE FROM BACK SIDE AND APPLY SILICONE NEMA 5-20R OUTLET 0 GLUE ONTO STUDS, THEN SET SIGN ONTO WALL; MAKE SURE IT IS LEVEL. cr_ NOTE: BLOCKING IS FOR OVERHEADS THAT MAYBE ADDED IN THE FUTURE -z- A - STEP 6: CLEAN SIGN WITH NON ABRASIVE CLEANER (WINDEX, ETC.) V z JOB NO. BLOCKING� EOUIPIVIENT ELEVATION w 15W .1i'*� GLAZED DOOR K10 ELEVATION � 12 SIGNAGE ELEVATION �A&1) TYPICAL TYPICAL �8.1 �A&1) 0 IT EQUIPMENT 521 w �A&1) 1/400=k��WIT SET: 02/19/2016 JLI _J ...................I UJ 215095415\4-DRAVANGS\ARCHITECTURAL\15-A8.1.DWG LER 02/19,/IE 10:01 1:96.00 FIRE TREATED 2X ELECTRO°/2 BLOCKING FOUR WINDOW STANDARD BLIND SUPPORT BRACKET SIANQ RD SHELVING — PL,6N VIEW: �: SAT PER PLAN; ROLLER TUBE AND SHADE TRIM CLG TILE - BAND ASSEMBLY (REGULAR ROLL) MOTOR � � AT EDGE OF ,.�' �_� NOt�""�"i f.r J` '' H0LL0w METALpR"t� BLOCKING Architecture al Interiors INSIDE TUBE a „ „ T f CLEAR GLASS _ �P� CLEAR Planning w Engineering 4 `14 a VINYL COVE BASE � C VINYL COVE&A-51E-51ENOTE: WINDOW MULLION j f� m (BY OTHERS) I I I Portland,OR � � 3 / 4" X 12" FINISHED MELAMINE SHELVES MOUNTED ON DOUBLE SLOT ��_`. 503.224.9560 STANDARDS AND BRACKETS. PROVIDE SOLID BACKING IN WALLS AS REQUIRED. "FL/R" "FG" Vancouver,WA FLUSH SMM Haas t100R w/ADJAMT REt M f1119k saw CORE DOOR w/FULL GLAM %%ION PAN& 360.695.7879 _ Seattle, WA STANDARD SHELVING ELEVATION: STANDARD SHELVING — SECTION CUT. � � ��\,\\ - ��`f� 206.749.9993 REFER TO PIAN WWW.mcknze.com SHADECLOTH WILDI ter STANDARD TRACK/MRDwARE LU � MACKENZIE, EXISTING MINI--iI ' "` aAss 12" OR 18" OR 24" BLENDS 'ys DESIGN DRIVEN r CLIENT FOCUSED DEEP SHELVING — I 1z SEE ELEVATION FOR $ FASCIA SNAPLOCO w Client DETAILS 1 34" 14" UJ o ` HEM BAR 511" Q I or --BUILDW STANDARD HARawARE E- SEALED o INSIDE 1 SHADECLOTN f SHADECLOTH E E x r IN DOWN "GL" 4 w 1 POSITION FILL BUTT CLAM DOOR w/ADdACWT MM CLAW REUTE w K�1� SHELVING ELEVATION 2 MECHO POCKET SHADE o 3 TYPICAL DOOR ELEVATIONS I \\,A8.2) 0 CLOSET 510 1/4"=1'-0" w A8a2 "=�'-°" AU 1/4"=1 P-O" w Project EXPERTS SUITE 500 TENANT IMPROVEMENT .:. ._ ►Secticl & aaflectn & 'Wor'4 ,. t1 eQnCe1 , •Data & Data Worldnq wI UNOOLN TOWER SS?w #vya ECIaAA Rt h aEWictrical To order 2 DtxartSne ktcation,gnanriy esti tirait of '5dxt Paver tiarnees modabt(8712XX), RG RD i t -: : Goncensys Ca nac�eme • 1. I>euerstmte,shitds der�ttieal►psoott you..tli dapikaec. Faux-'Tbm cob+eg tB71o)c?Q aur Pam Tions Cable Management �� use after COW41ti g your decaidao sad X DDeoennint the approptiaoe ctmia and use of Barrows(On 1 VQ rids the last two digo concen fns Eledrical Applications •A 8carued decodcittn meat make 00004 Cow •the Pawed iv all panch adiaaeat to cable capacitiesce6de Cepar3da ' =10pouort pG'6�ur support bolatsd,L�iaual and Sepata:s a aospooding wash the panel width luta • •C,once"pent:ac 1IL 1I"Listed., to a EtipplY is � for Routing in for Routing in T1LBl'iRQy Vf7G\.TJIM F ' covTontor positioned. Flactraal oDaapaoeepl ue UL LIsiad aril fSsl *10 power alt pauteb at a•IEE*romtction, *lre&aaIs and Lateral Pita, under as •llsefotudnsudt Berta appruint. irbuchthe is llae u r mLeatantYotasrtfasearsmwtbeand;ads waluutdseta,maytens, sotae 7erclsttology "t Tanelsfogy x (44401 bNsRttraV3 Cmumd) 4, Spueify apptaptita�e Power tiatrrxea`nail iruti+ti orbit&aR is tats int • Panels Ptuuisftom -..•� -..� �`�•. - 3+11 option Ps:-11tra CAbleal approrima dy 3"m tramverse IVA CRCJSS, a M ��� •R is tits cull oc aers twpoes"ty to ensure i1tOSS,rt ixast xtrD Fowts l�ooeues nwa inaccessible,sod may prohibit tee of at Boldine � } _ �lr - 2+2 on 5, Daetmioe td r lacaano,gttanticy ami of Sol.tsad Btreudtd Cxmntrwrs: a be seed gramme Bas+of Panel 'app type Sttaigbt that rue of the(se wired etxuia!syatat,the i5ide Yiavr} t o� -C.o+gb tD Battfini, Knod our dm seine c ��V h lilantasnu will to 3Y4" m an Fotsrriremt r and Yhreectcmr C•xvar Cst,t+. # •11te three-ttrrme aymem Power ht•fted nlssded. Wanbtr of mapotda used on#glveR Carrott, uP / span • t• . .r' 8,araed at Yth'iaurfw�e I M, 2.htD'W x 1.37rN c (3-fiorJ3 NaattaY2 Cround) �t and c:> am to a bml&q;power soup, Tl S7 RAMI panel Qnoseztiwa caaspaoenx(wtiuh suffix"A"?cannot be used '�'A'�� Lwd kkh(.lrierni7 r ^fir.+lort2 tr V1 `f' z= be in cosnpuatam wrap an 1••scai and satioad '7trlraa=old*I$`tN panda aro caaemctod at ooIIaha c 'taste sv h d 5c 72'Dw."a, addsoostsl W Yeas n . eleckacalaodes, ip� I y Rana. Ftesroonnsct'"Fiectrieal�t5-y�~_-' options You can afro choose a sE¢m a verse,a8#tawttx system that Ewa a � r� tdam#•yy� �� _ s"1EE• OSS"omoeeaiom,rn • 1bn►cabix tilted A Q. l'bE b•DMGlttiit.Y vaite dLtSllCal Syaseof wtdriY oend dedicatal lJGeRTaI for esetY hot Cittait.l�ht tdY'eefittnit CgmpWteFits - '':11ree " it;so �neu'� c - 6%figRaiok ?f trussed by btatdtsdsof ttssausawk of end-users.'ThispsDrm system have maddJ ttmnbeea wilds as"A's>dfDrae3 appear in a 8*aT beer ffi this I at7bpaadR4'delle, o delivers fou dwaits for every power inked in either a 3+1 a 2+2 Pie 1 2 3 '• sf a dela is amp 24arr4t ... t.Yefaadsnes e+er.apnaow Dupisrs RaaPte conligutarlraa Tbc isolesdtdcd eared deaden arc ideal#tw xttsa+x r^1 ,F Electrigt Povwer Hsrnos► •15 amP nada con6�csaan •: ''' t I--1; �i -r •lNadeh$71601 and 87160tH have a ri' a' Y � t g 4 P0 D, EGON �P equipment.while the mrssttnota aisettitu are sasabe for tonnes Copi rs.sasltiigbaand other palipbencls.Baththe 3+I sod 2+2 ' '» iii` 20—Prada-6gutapoca-q lad ' p' G�yaBs Sectional Vtewll of cable Mana�sro9►rt 4 �+ aymmseastthesousptewindooetpadEaa, it easy tos4=as 1hathewsckeusiyaegrtrnleettetrlp4sl� ionlsSwisrsaSopdou' a €p "^, by ansae cattle Management--ctotra•5eetiorael%f�aws � ' destttsal ne9eh rdtauttgc cheer ptxlrltdta sawxxds,#ns saltie of the dorsa alts'%leve' s ' :' rA e fw flocull"I w Har i.. s Ph bedc-toolIack leen rice YtNtar Blocks)of Pawn and Pass-71st r!z'tiro 14.'se�G"obnRtatd _ T rtpc pssha,.saar�tOrl oDaC uEis' In-Feed p!i 0 Na ver a, rte wa. ! T s •Iabebd Duh the provided aroatte Gneiss connected to the Isolated h F+sad Cshie :x.t`,(,C} + 11 FSttir-ei +'1 Roc de tyti p «; •Used so&nn meepower in panda 24"W cad widee Caouzed azo idaAi6ed with�w�srtiangag circuits the do eat r}( � .h� 2 f(.,1.� }tis :\ � r 4 ismtbrt t A�s ',1 t/usd a enc ffi i} tboatilt tlis4 pr 41.` •Can be mooted in Ila hasepadmay and above the wodowrfane_ dam a acutta or goand ban an arsage ciecuic nsmtbd 2 $ a rpm v�✓, ;iris` )i�j INC) decdbasian len aides �essticc ="g, rfae v»re titCura - t 1 et r Specify Power Iiateeas m needs pod width. Power 1mfood Bsrse/Caft Modeba 879072. _'ry h r'Y ti ;r , 011 2 otAr+exttttaracec .� 2,` t .?JC,.� wMACKENZIE 2016 Tbt 3.1 option is tbt daowcal sundard used oR AlJdod systema CeMCtsT t tamer t 060* 00 •Doublovdodt ceoeptsds><can be maned two both aids of Power 879072A,$79169 acrd 8741689 -" a�+ ,.. w. ALL RIGHTS RESERVED P' for amw 7a+s in start itesalla<rioos.•psis--S("—pttrvadcs t eirtRd 3 D D P A * :�( i_ " t. 2. Blactts. •Used to ctrattsez the rtiacotipl ,�?'' dam usalityorcuatsplus anagaw&dedicaudcutuitfix nxtte a z.t •Uscpo-crharnessainall panchcoarWredadla=9wI9"Wl� sysamwflat building decuial ,lj THESE DRAWINGS ARE THE PROPERTY (if run is m he dcarifed}, • 4f . w J�. t rot, soasid"eguipanartt.arcuit 2lors of the 3 eomoma cimiks SMr ,"mwa"`r'c: .. CA c Paie1 97916 Ain e'9168a ' t:� � < y t OF MACKENZIE AND ARE NOT TC BE t 4 ahatugattearraEvrwepcamantbsuredwtthaaglePhastbtuldso8 r wrtroer tmraw sVV�seais S79E6 USED OR REPRODUCED IN ANY MANNEF t� tws t+assRia tlattakul supply f batSrkal free ttxu Gtsiar y 4' S I t+_ �2yc,<--�� f`_. nC,x: -- +aota�maaz a4At - _ '4t' �. ,s tache dwttiral �:...._ ._,C r r X41 r rTHOUT PRIOR WRITTEN PERMISSION tteaG�a t _ +oppty,is a Collinsoati+zplest� $ for 53.22'rGa.cables. Space for 39.224 ills_Cables. Space for 40 22,tic tablas_ ares.pb y re t"r featvar tlartrrwrt3ttaaaf paMsanOas►na scree +ro•s VGA - a ssrud.te7ptDtecauxseparately. htotfe1870070 Model870t171 ��. •A iieesed clteDtirian sada nsakt arrystactiaas m s ck arical .; 9 wnetatatv�rAa t entwan otaaxrr o�cst s oeraCAirD Pasri't bans Gab4 Withatr Dtgdcsr Capacsty PtatadCommcaioatio n POW 1 Power/ 3.775 asi.IrL ` T REVISIONS: ftiswrs r for see im18'W Panels or whmna a to wPpEy8 8 aq.M. Z is a f' cwmaesys Recoprtadia Usage s teo�tade to�u�•SAeeifY •Plap uany s 4,5 00"C' mile rter}xsrde position;an be created k&or rtghr tea urt4ant os Pile suffix r c{ owe rmm•t-z.. ,._ .... taw - •1ou4iraa oompocena and dttte•G toait "r aq ' ad • UL Based,puck,Liyuidl as (aoeside disunwtor` { - Q onurlw ger _ tutu +Aiiottspowe 3StribttriaethratsShpersclavnc�ctotgaaclasranssttthe • C+1TWfra >J REVISIONS CLOSING DATE DELTA s ranrE a•nw.r _ tow Rea tF►Nts,1!0 amp[t 5 amp cAsaaativas}aiottrGaal aysersns a re aftsaaxl a a r Cable kamb cannot be sar tcha >4.} � t x U)F- ascan rraro ... +xw ElacnieatSystem Cara n RecoptadaGP•ety stdfsa piRDottbe Pa YStandarSH EET MCI Nounit A Matt be.poddow dtronb a neocrude ope q iA dw base e+4 4r „» Fan an. nw eore;psiottosarixmaan mtbe sottoce ' SLUE rar.a _._.._ uoA co ntnon c o"nort Convrron bolDerlarad •t a► persepet of the two rpmetm an •T 1$'1F paaleis arc Conaelted ua"IRE`a•Qt05S o S TT _ . Cormeemr Bracket Model CCK to w porn drtuit 3+1 t3 ttrtt-1 Caa+h-2°! Cireun 3 C1tvAn 4 _..tray loeY d7 ns 1> its ptsrapttieo,anadditie eel iR'%4 Pea ilsss t abbe o naQoned. ; » r hatasndtlrottra 4 riotfZ Naxu4dlY OnwNf 671591 tr?t5t12 071509 tty7504 Potwar In-Feed Moda(871472 and 8714729 tea nm �1 :; � 24 � _.._._ .. ....._. _. _.. orssas to , O8 peeps coermnn Common saotsaad Wow conpo�ofaf snothes seer�. � 6leetricd Pass 3htu Harnaasss i?T M *Used m tbaw.ct the paid daaeetl system to tht building electrical eae+swtca M rsautral vrirast 2+2 Csrwit•1 C+rtu i 2 C"'va 3 Grait•4 .AUsnad mode{suabem am printed oo c� Y,cf�y 1,.i �.r,i 7 supply. atew*w I x ELL Four-circuit, 2+2 Recepltade Option a715at tm so2 Ylt306 mea the VL Eabels,and compoamts ant color r ' � PwTsru Hunan w •A licensed cla�itisnanauxtsnake connoedass to a building cieariwi `s L a 1 Y 3 4 tt Hotl$'Nrtrtrd/Y Gt rand :vrliotwt w ,. r 1"rct4lt t Clteti tr2 CistWt.3 NEA r Pl Tltieedrctalt gab Common Commas : to"to n; ' .r Mrddantae " y paws paxawa3' Csb4eMaaimumSend Radius at tine err•+ -k 40 tnulrah ; the&Fmcnt compocrnts h �� � for t2 w tv ndr��.��t, • into the ted of a block.[he Fed a#-Fonar base i 1 i CK 4k?�4 i 0715019 ,c 8l1302A ionliam' ewer can be field cut to provide ansocess port jai"- ro 11,t y�uSs n�wwat trirral• l .Pour edrtust compwomts bave.blade t r <w tYr ,,; J c1}Ciscust•2 kava of de 3 cosamao ataits sb Pi I •Mailer%uses U &u csWt coodus--ao earn be left I . .e k.'�,.., ;� _. r� '!'lac 2+2 tan is a ears 'at that a the mal wiW Damn be used with a si.•tglel)aasc b "6C Pam "m fl c .z.l, tparr l'bro Nasaaa Watt t3 lest C.apacty: ,/ Fortran ` .�. .. TEE .. tics tyre stn' r3ri tea *three cacattrt team nets sett *Por arc ir.24"W and untie tntpostd 4 M + d t wiring Pwv' tu} �2 sod recepoidt in p s7p xccspudm required. aka msta8atiaa dtvstirs orad two isolated sera fat eters exvseivc pPl'r• po h= panda' v Use rwp applirauoue terminal ro i r Ute wbea tpeafling bads tiw and elelvrin; hddioe hdSbc Power tmfaod Modals 871412.571912A, j -4 ti~t V` 5r 1 9 g w, w 871918 and 87141$9 8 r0 r i'o ib y' Added librate!m capacit+fat ams teuxpmca a each side of s pend ' a,sxweecn,etr Cnc;r t :•4 Duplex Reakpts des �r' �;t� f� leatru a offers kaesmc expeoson and is an ahcaative to Power •Uxxi to coraact the pend electrical syn e n toft � 4 Data Port iGt iCt)PS t } Hee Me Hes wee. tartaric sautwaa tsaArea rasxA rn Typical power,ttsaaget by the most eantrnonly'Specified office equipment '. �J building electrical supply,in a caths$plm=arca. / Knod'.out dinwwotvs; 2 4 ver m e s '` Power Pale 870071 mnu be ordered C3tv55 s p s3 EOUWMENT AMPS EOUiPMENT AMPS fi*"ENT AMPS p C1 toy Iww x atdY 2.t1 i'Wa1.377'H s ?u� rr%traa rtu w» o o t� as y Elecn4pl.iL Gbift ' iq erg Cap tles w atptr •A licensed elachicisn=w make conseeticee M s rapfeawtaJ.r of For addi8twtal dais ds,the Ceuetedees RotRl ea Coptarts Ftttc NNaddnaa d ` •Connect power from base IvAwsy m beltrae n needed.Jumper cable deco ial supply. � Data Port KA(CDP)can be field When routing table ham caWoway top x r conA Naeebooir� _,.__ » _•,-3 lkdcooptapace »_. _._..15 7ukJetPatt _._._ __ katthaw1 t5 power block end ofelectricalpowerhataeaareitarical PEagsinmthecardofa Voda instaiwdForTechnologyPatelordythrough nnMw.; veru ttrttpReoaptacdr intD • 'TEE'or'CRO$S"ConrtaeOoeta atom w t Caeapotrr.. .«. „_.3 Console Copier .. _.20 Zttermal Paz. ._ ...« .lees titan 1 t Etna atkditiatd erld beard ars *Ate+ Nwrea earn owner `" ;ziaa s , mha�oes •Mt 4raatlpl e�erafkearat,dt l �'"— ` tN r SHEET TITLE: x lUa aleta ease t as+e "er-s tau Monitan C apter lalwttwe..»,. .. 3U Plain paper i az. _._. ».».».».»S ,p 4 .y 1971336 s 39•w jot np from tsuc pathway so hd liuc. Nate hrttr�cibks hued ahwm be fietdcot an desired 24 CAT SE with Etartsieal am nwdad.Order moria!CCK—W$a t d2. 4 D x s 4 mdF length. SE w d o r fkac*altal 13'Color hfoaittrt.».. . ..» 2 Prmtars Tads Lights o ca r, •ylt l$713 is 78'and used w ssxisttaia powtr at ttettl nc at 90' Isemorc LL L #{JSt$aaatic label:tui ort onto the,cable icer ttat�c rot-, to A 17"Ceclor bkonitear.....»..........._...... Dot Matrix... ......._...._. ?ens stun 1 36"Ch nueaereec'..,,.,__._0JJbWb 3. tgxsiti 8t}r, CAT . Ca-ere^G•and tira:+W >;. co:arect+an. ;Lower Base Pathway , 21`Color.,ascan..... ..............„..4 iakjer_.,...,,.,........,......._.._.Ic a than 1 48”T8 Flncrew rr,__,,_.»A 131btdb M wtp� ELEVATIONS A�ONS >x� 7 D ALS AND Pu►%tea!Levret err 1.P.1)...:..». »:.9 (Required by some ,. ,< All elutrcab pnw:r:sr:rtsx.�and}rags-thea baraczacx u41i ztrctCh 35• (203 tom.in.below Paws Btoci:, �,• t o-J t,.,ys e.!"..Rncsrrx.,NY W oracgroup l etre a-1 FD.......»»...t C large Copiers) no spas ixuertetxions and Doti neaiaas.Jm;xn span Tram bcw ere so 6.27 sq.in_w/o Power Block far Cable i+lan sgamaM Tray 1.54 i ts$IFceW' Symms-212005 baseline,around corners and back m bekiine o tt ng Leta Cables.) roe aJ` � oksc•face 1.5. I A1r Systems-2!2405 Systems-2J2005 allsteelokfice.eomr 1 1.53 Systems-212005 allsteeloflice,eom l 1,51 tJ W 4 EXPERIS FURNITURE SPECIFICATIONS 1 1 98.2 NTS U_ DRAWN BY: LER CHECKED BY: SBH/PDK SHEET: A8,2 JOB NO, 2150954.15 PERMIT SET: 02/19/2016 215095415\4_DRAWINGS\ARCHITECTURAL\l5_A8.2.DWG KJF 02/19/16 08:27 1:96.00