Report (29) r5UP)4 ? - C)0f7i e' ao 5b.%) ,ki)--±rr Scope of work is for the design of the sign pole and the foundation. .`$EO PROs eN See following pages for structural notes. C. rG t N E�"J/o i 4, 7252 -E' di LOADING: WIND: ASCE7-10 120 MPH,EXP B MAXIMUM HEIGHT(h)= 7.50 ft Pr t•N o° O (3 second gust) GUST FACTOR(G)= 0.85 `4�f ry K1 = 0.00 (ASCE 7-10 Figure 26.8-1) ",.Cr�t' 0% . ���Q K2= 1.00 (ASCE 7-10 Figure 26.8-1) F=qz*G*Cr0.6:(allowable) JOSEPH K3= 1.00 (ASCE 7-10 Figure 26.8-1) Kz qz F(psf) h Kzt= 1.00 (ASCE Eqn.26.8-1) 0.57 17.86 = 13.2 0-8 ft EXPIRES:12-31-2018 Kd= 0.85 (ASCE 7-10 Table 26.6-1) Cf= 1.45 (ASCE 7-10 Figure 29.4-1) 8,-0„ s= 7.50 ft s/h= 1.00 B= 8.00 ft B/s= 1.07 0.2*B= 1.60 ft(code offset,for wind load) offset= 0.00 ft(horizontal cabinet offset) FORCES: w/%5*H Height to Height to Area Wind load Force Height to Moment 10 3" DIA. Width bottom(ft) top(ft) (sq.ft.) (psf) (lbs) center(ft) (ft-lb) I SCH. 40 I- PIPE I 8.00 I 0.00 7.50 60.0 13.2 791 4.13 3263 E= 791 E= 3263 SIGN POLE: (Single Pole) Try a 3"SCH40 sign pole - Z= 2.19 in3 T= 1266 ft-lb =791*(1.6'+0') I Milt 2,500 PSI Fy= 35000 psi Tc= 3601 ft-lb 7--) CONCRETE Mx= 3263 ft-lb 0.35 >0.2 comb.stresses req. FOOTING My= 0 ft-lb Mc= 3825 ift-Ib =35000*2.19/12/1.67 2'-6" 3825>3263 OK Comb.= 0.977 <1.00 OK SQ. I Use a PIPE 3"SCH40 sign pole CSI GN E LE VA TI ON NTS FOUNDATION CHECK: Mnet= 1.07 k-ft =(3263)/1000-2.19ft-k P= 0.791 k Applied lateral force h(effective)= 1.36 ft distance from ground surface to P q= 300 psf/ft allowable soil-brg., q=2(150)=300* Footing shape: Rectangular *Allowable w/1/2"movement at groundline b= 2.5 ft (in the plane of the page) L= 2.5 ft (into the page) b'= 3.54 ft diagonal dimension of a 2.5'sq.footing d(estimated)= 3.00 ft Estimated embedment Unconstrained Condition volume of concrete= 0.7 yd S_1 = 300 psf q*d_est/3 footing wt= 2.8 k A= 1.74 ft 2.34*P*1000/(S_1*b) sign wt= 0.50 k d= 2.7 ft A/2*(1+(1+4.36*h/A)^.5) Total wt(DL)= 3.31 k 2.70<3'OK eccentricity of load to reaction(e)= 0.66 ft=2.19/3.31 maximum resistive moment available based on soil bearing,Mes.= 2.19 ft-k Use 2'-6"square x 3'-0"deep 2500 psi concrete footing 9570 SW Barbur Blvd Solutions Yes Monument Sign Project Name 9 Project# 170605 Suite One Hundred - MPS Portland,OR 97219 MkLocation 8300 SW Hunzinker Street, Tigard, Oregon MILLER Client Security Signs Phone 503.246.1250 CONSULTING Fax 503.246.1395 SMH5/9/17 1 of 3 www.miller-se.com By Ck'd Date Page ENGINEERS GENERAL THE CONTRACTOR IS RESPONSIBLE FOR VERIFICATION AND CORRELATION OF ALL ITEMS AND WORK NECESSARY FOR COMPLETION OF THE PROJECT AS INDICATED BY THE CONTRACT DOCUMENTS. SHOULD ANY QUESTION ARISE REGARDING THE CONTRACT DOCUMENTS OR SITE CONDITIONS, THE CONTRACTOR SHALL REQUEST INTERPRETATION AND CLARIFICATION FROM THE ENGINEER BEFORE BEGINNING THE PROJECT. THE ABSENCE OF SUCH REQUEST SHALL SIGNIFY THAT THE CONTRACTOR HAS REVIEWED AND FAMILIARIZED HIMSELF WITH ALL ASPECTS OF THE PROJECT AND HAS COMPLETE COMPREHENSION THEREOF. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONFORMANCE TO ALL SAFETY REGULATIONS DURING CONSTRUCTION. THE CONTRACT DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE. UNLESS OTHERWISE SPECIFICALLY NOTED, THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION OR CONSTRUCTION LOADS. ONLY THE CONTRACTOR SHALL PROVIDE ALL METHODS, DIRECTION AND RELATED EQUIPMENT NECESSARY TO PROTECT THE STRUCTURE, WORKMEN AND OTHER PERSONS AND PROPERTY DURING CONSTRUCTION. THE CONTRACTOR SHALL, AT HIS OWN EXPENSE, ENGAGE PROPERLY QUALIFIED PERSONS TO DETERMINE WHERE AND HOW TEMPORARY PRECAUTIONARY MEASURES SHALL BE USED AND INSPECT SAME IN THE FIELD.ANY MATERIAL NOT AS SPECIFIED OR IMPROPER MATERIAL INSTALLATION OR WORKMANSHIP SHALL BE REMOVED AND REPLACED WITH SPECIFIED MATERIAL IN A WORKMANLIKE MANNER AT THE CONTRACTOR'S EXPENSE. THESE PLANS, SPECIFICATIONS, ENGINEERING AND DESIGN WORK ARE INTENDED SOLELY FOR THE PROJECT SPECIFIED HEREIN. MILLER CONSULTING ENGINEERS DISCLAIMS ALL LIABILITY IF THESE PLANS AND SPECIFICATIONS OR THE DESIGN, ADVICE AND INSTRUCTIONS ATTENDANT THERETO ARE USED ON ANY PROJECT OR AT ANY LOCATION OTHER THAN THE PROJECT AND LOCATION SPECIFIED HEREIN. OBSERVATION VISITS TO THE JOB SITE AND SPECIAL INSPECTIONS ARE NOT PART OF THE STRUCTURAL ENGINEER'S RESPONSIBILITY UNLESS THE CONTRACT DOCUMENTS SPECIFY OTHERWISE. NON STRUCTURAL PORTIONS OF PROJECT, INCLUDING BUT NOT LIMITED TO PLUMBING, FIRE PROTECTION, LAND USE, SITE PLANNING, EROSION CONTROL, ELECTRICAL, MECHANICAL, FLASHING AND WATER-PROOFING ARE BEYOND THE SCOPE OF THESE DRAWINGS AND ARE PROVIDED BY OTHERS. EXISTING STRUCTURAL ELEMENTS ARE DESIGNED BY OTHERS. SPECIAL INSPECTION OF WELDS AND POST INSTALLED ANCHORS ARE TO BE PROVIDED BY A SPECIAL INSPECTION AGENCY AS REQUIRED BY THE BUILDING OFFICIAL FOR ELEMENTS OF THE PROJECT THAT DO NOT MEET THE APPROVAL OF CONSTRUCTION OF A MINOR NATURE OR AS WARRANTED BY CONDITIONS IN THE JURISDICTION (SECTION 1704.2, EXCEPTION 1). CONTRACTOR TO VERIFY ALL CONDITIONS PRIOR TO FABRICATION OR INSTALLATION. ENGINEER OF RECORD FOR THE PROJECT IS TO BE NOTIFIED IF CONDITIONS DIFFER FROM WHAT IS SHOWN ON THE DRAWINGS. BUILDING CODE ALL PHASES OF THE WORK SHALL CONFORM TO THE 2014 OREGON STRUCTURAL SPECIALTY CODE, BASED ON THE 2012 INTERNATIONAL BUILDING CODE, INCLUDING ALL REFERENCE STANDARDS, UNLESS NOTED OTHERWISE. DESIGN LOADS THE FOLLOWING ARE THE DESIGN REQUIREMENTS: STRUCTURAL DESIGN CRITERIA ,`�ti PRO,e,n RISK CATEGORYII \S ac, % N FF // WIND DESIGN DATA ' 7252 E e BASIC WIND SPEED(3 SEC GUST) 120 MPH EXPOSURE B ^ • o / 11 o 9�lFS 44. /r os , JOSEPH\ EXPIRES:12-31-2018 9570 SW Barbur Blvd Project Name Solutions Yes Monument Sign Project# 170605 Suite One Hundred Portland,OR 97219 gla Location 8300 SW Hunzinker Street, Tigard, Oregon MILLER Client Security Signs Phone 503.246.1250 CONSULTING Fax 503.246.1395 SMH ( 5/9/17 2 of 3 www.miller-se.com By Ck'd Date Page ENGINEERS FOOTINGS FOUNDATION CRITERIA CONTRACTOR SHALL VERIFY SOIL CONDITIONS AT THE FOOTINGS AND MAKE ANY NECESSARY CORRECTIONS TO PLACE THEM ON FIRM NATIVE SOIL OR STRUCTURAL FILL COMPACTED TO 95% OF MAXIMUM DENSITY AT OPTIMUM MOISTURE CONTENT PER AMERICAN SOCIETY FOR TESTING AND MATERIALS, ASTM D698 (STANDARD PROCTOR), OR ASTM D1557 (MODIFIED PROCTOR). THE COMPACTION SHALL BE VERIFIED BY A QUALIFIED INSPECTOR APPROVED BY THE BUILDING OFFICIAL. COMPACTED STRUCTURAL FILL FOR DEPTHS GREATER THAN 12 INCHES SHALL COMPLY WITH PROVISIONS OF AN APPROVED GEOTECHNICAL REPORT. ASSUMED SOIL BEARING PRESSURE 1500 POUNDS PER SQUARE FOOT(PSF). CONCRETE CONCRETE MIXING, PLACING AND CURING OF CONCRETE SHALL BE IN ACCORDANCE WITH THE AMERICAN CONCRETE INSTITUTE, ACI 318 AND IBC CHAPTER 19. CONCRETE SHALL BE 3000 POUNDS PER SQUARE INCH (PSI) MINIMUM AT 28 DAYS. (DESIGNED FOR 2,500, NO SPECIAL INSPECTION REQUIRED) STRUCTURAL STEEL STRUCTURAL STEEL ALL STRUCTURAL AND MISCELLANEOUS STEEL SHALL BE ASTM A992 FOR W-SECTIONS AND ASTM A36 FOR ALL OTHER SECTIONS, PLATES AND BARS.ALL RECTANGULAR HSS SECTIONS SHALL BE ASTM A500, GRADE B, FY=46000 PSI AND ALL ROUND HSS SECTIONS SHALL BE ASTM A500, GRADE B, FY =42000 PSI. ALL STRUCTURAL STEEL PIPE SHALL BE ASTM A53, GRADE B, TYPE E OR S, FY= 35000 PSI. ALL STEEL IN CONTACT WITH ALUMINUM TO BE STAINLESS OR HAVE A PROTECTIVE BARRIER TO PREVENT CORROSION. UNLESS NOTED OTHERWISE, ALL BOLTS TO BE ASTM A307 AND ALL ANCHOR RODS TO BE ASTM F1554 GRADE 36, WITH MATCHING NUTS. ALL FASTENERS IN CONTACT WITH ALUMINUM TO BE TYPE 304 STAINLESS STEEL WITH MATCHING NUTS OR HAVE A PROTECTIVE BARRIER TO PREVENT CORROSION. NUTS SHALL BE TIGHTENED TO A SNUG TIGHT CONDITION PER RESEARCH COUNCIL ON STRUCTURAL CONNECTIONS (RCSC) SPECIFICATION FOR STRUCTURAL JOINTS, SECTION 8.1. ALL STRUCTURAL STEEL SHALL HAVE ONE COAT OF PRIMER, EXCEPT SURFACES TO BE EMBEDDED IN CONCRETE OR MASONRY. EMBEDDED SURFACES SHALL BE FREE OF CONTAMINANTS. ALL ZINC (GALV.) COATINGS ON IRON AND STEEL PRODUCTS SHALL CONFORM TO ASTM A123. REPAIRS OF GALVANIZED COATINGS ARE TO CONFORM TO ASTM A780. ALL EXPOSED STRUCTURAL STEEL TO HAVE ONE FINISH COAT OF RUST INHIBITING PAINT, COLOR BY OWNER. ALL WELDING SHALL CONFORM TO AMERICAN WELDING SOCIETY (AWS) D1.1 USING E70XX ELECTRODES. WELD LENGTHS SHOWN ARE EFFECTIVE AS SPECIFIED PER THE SPECIFICATIONS OF THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC). WELDING SHALL BE PERFORMED BY AWS CERTIFIED WELDERS FOR WELD TYPES SPECIFIED. WHERE WELD LENGTHS ARE NOT SHOWN, THE WELD SHALL BE FULL LENGTH OF MEMBERS BEING JOINED. ALL BUTT WELDS SHALL BE FULL PENETRATION WELDS UNLESS NOTED OTHERWISE ON STRUCTURAL DRAWINGS.ALL WELDS SHALL RECEIVE THE SAME FINISH COAT AS THE MEMBER BEING WELDED. STRUCTURAL APPLICATIONS RETENTION OF 0.60 LBS PER CUBIC FOOT OF ACQ OR 0.31 LBS PER CUBIC FOOT OF CA- B BASED ON AWPA USE CATEGORY STANDARD UC4B. FOR ABOVE GROUND, CONTINUOUSLY PROTECTED FROM LIQUID WATER APPLICATIONS (SILL PLATE) RETENTION OF 0.25 LBS PER CUBIC FOOT OF ACQ OR 0.10 LBS PER CUBIC FOOT OF CA-B OR 0.25 LBS PER CUBIC FOOT BASED ON AWPA USE CATEGORY STANDARDS UC1 UC2. 503) PROFF , \ �G 1 N Eck .c, '4 7252 'E P e o '` 9'pl �► oa ti��� Fs"OSEN* ate EXPIRES:12-31-2018 9570 SW Barbur Blvd Project Name Solutions Yes Monument Sign Project# 170605 ' 04 Suite One Hundred Portland,OR 97219 MkLocation 8300 SW Hunzinker Street, Tigard, Oregon MILLER Client Security Signs Phone 503.246.1250 CONSULTING Fax 503.246.1395 SMHOM 5/9/17 3 of 3 www.miller-se.com By Ck'd Date Page ENGINEERS