Loading...
Report (34)The equation in the 2015 National Design Specification for Wood Construction (NDS), Chapter %` E 16 — Fire Design of Wood Members to determine the fire rating of the exposed wood decking City of Tigard Community Development pp— Attn: Jeff Grove 2" member. 13125 SW Hall Blvd Reff= 1.2Rn/to.187= 1.2(1.5)/ 1= 1.8] v') Tigard, Oregon 97223 a—+ L_ Table 16.2.1.A, of 1.8. (T): 503.718.2436 Section 16.2.5 — Provisions for Timber Decks places a 1/3 reduction on the effective char rate t5 JeffG@Tigard-OR.gov WWW.11-ED.corr 16 -May -2017 (A � Mr. Grove, C— C:) Below is the response to your field inquiry on May 16, 2017, as relayed to me by the general Q C;) contractor Dave Whitney of Radian Construction, regarding the fire resistance rating of the . , exposed wood decking of the second floor. Cll P`_ LL' r—I In accordance with the 2014 Oregon Structural Specialty Code, Chapter 7 — Fire and Smoke Protection, Section 722 — Calculated Fire Resistance, Sub -Section 722.1— General: "...The o CL calculated fire resistance of exposed wood members and wood decking shall be permitted in 4-j D accordance with Chapter 16 of ANSI / AF&PA National Design Specification for Wood m Construction (NDS)."; as published by the American Wood Council. CL Ln The exposed wood floor decking is calculated as shown on Sheet G102 under Fire Calculations the floor assembly is calculated to have a fire rating of sixty (60) minutes, as Z3 E required by Table 601— Fire Resistance Rating Requirements for Building Elements in Chapter (ll i- 6 — Types of Construction in the 2014 Oregon Structural Specialty Code for Type V-A LL rL construction. I The equation in the 2015 National Design Specification for Wood Construction (NDS), Chapter %` E 16 — Fire Design of Wood Members to determine the fire rating of the exposed wood decking is as follows: 3" Tongue & Groove Decking (2-5/8" actual dimension) has an effective char rate of 1.8 for a 2" member. V Reff= 1.2Rn/to.187= 1.2(1.5)/ 1= 1.8] v') Meeting the requirements of an effective char rate for an 1 -hour rating, in accordance with a—+ L_ Table 16.2.1.A, of 1.8. Section 16.2.5 — Provisions for Timber Decks places a 1/3 reduction on the effective char rate t5 for exposed wood decking. For a 2-5/8" member this reduces the fire rating to 52 minutes. M 2.625" / 2" = 1.31 1 1.31 x 60 min. = 78.6 min. 1 75 min. (67%) = 52.66 min. j However in the technical report published by the American Wood Council regarding the UL E testing for the 2015 NDS, the 3x6 tongue & groove decking is placed between 45 — 54 minute fire ratings. For the purpose of our calculations the 45 minute fire rating was used; and when coupled with the diaphragm sheathing (5 minute rating) and the flooring subfloor (10 minute rating) the exposed wood floor assembly achieves the required 60 minute fire rating as 4= V shown on sheet G102 under the Fire Calculations. fCI Cl.. If you have any questions, please contact me at the information below. Thank you, Nate Carter, Architect Eleven Engineering & Design 971.344.1919 Nate.Carter@ll-ED.com 1of1