MMD2017-00014 NOTICE OF TYPE I DECISION MINOR MODIFICATION MMD2017-00014 's TERRAFIRMA TIGARD 120 DAYS =June 1, 2017 SECTION I. APPLICATION SUMMARY FILE NAME: TerraFirma CASE NO.: Minor Modification (MMD) MMD2017-00014 PROPOSAL: The applicant is proposing a minor modification to an existing development at 7920 SW Hunziker Road.Specifically,the applicant proposes to expand an existing concrete loading dock on the northwest façade of an approximately 15,000-square- foot industrial building. No changes to the on-site parking or landscaping are proposed. APPLICANT: TerraFirma Attn: Scott Kovalik 7910 SW Hunziker Road Tigard,OR 97223 OWNER: Wall Street Industrial,LLC 7900 SW Hunziker Road Tigard,OR 97223 LOCATION: 7920 SW Hunziker Road;WCTM 2S101CA,Tax Lot 200 ZONING DESIGNATION: I-L: Light Industrial District. The I-L zoning district provides appropriate locations for general industrial uses including industrial service, manufacturing and production, research and development,warehousing and freight movement, and wholesale sales activities with few, if any, nuisance characteristics such as noise,glare,odor,and vibration. APPLICABLE REVIEW CRITERIA: Community Development Code Chapters 18.360.060.0 SECTION II. DECISION Notice is hereby given that the City of Tigard Community Development Director's designee has APPROVED the above request. The findings and conclusions on which the decision is based are noted in Section IV. MM D2017-00014 I'crraFirma 1 THIS APPROVAL SHALL BE VALID FOR 18 MONTHS FROM THE EFFECTIVE DATE OF THIS DECISION. SECTION III. BACKGROUND INFORMATION Site Information: The project is located at 7920 SW Hunziker Road; southwest of SW Hunziker Road, and northwest of SW Wall Street. The site is also located directly adjacent to the TriMet Westside Express Commuter Rail,and Potso Dog Park. The 6.69-acre property is made up of one tax lot,and contains two industrial buildings, on-site parking, and associated landscaping. The property is located in the Light-Industrial (I- L) zone. SECTION IV. APPLICABLE REVIEW CRITERIA AND FINDINGS MINOR MODIFICATION OF SITE DEVELOPMENT REVIEW: Section 18.360.060.0 states that a Minor Modification shall be approved, approved with conditions or denied following the Director's review and as follows: 1. The proposed development is in compliance with all applicable requirements of this title; and FINDING: The applicant proposes to expand an existing concrete loading dock on the northwest facade of an approximately 15,000-square-foot industrial building. No changes to the on-site parking or landscaping are proposed. Based on the applicant's submitted site plan, staff finds the proposal meets all applicable development standards for the I-L zone, as outlined in TDC Table 18.530.2, including minimum setback requirements. Upon review of the applicant's plans and narrative, staff finds that all other applicable requirements are met. This criterion is met. 2. The modification is not a major modification. FINDING: Staff finds that the changes listed in TDC 18.360.050.B.1-11 are either satisfied or do not apply. Therefore, the proposed development is not a major modification.This criterion is met. CONCLUSION: The proposal is a Minor Modification of existing site development and is in compliance with the applicable requirements of this Title. SECTION V. PROCEDURE AND APPEAL INFORMATION Notice: Notice was posted at City Hall and mailed to: X The applicant and owners X Affected government agencies Final Decision: A Minor Modification is a Type I procedure. As such, the Director's decision is final on the date it is mailed or otherwise provided to the applicant,whichever occurs first. The Director's decision may not be appealed locally and is the final decision of the City. MMI)2017-00014 Terral�irma 2 THIS DECISION IS FINAL ON MAY 4, 2017 AND BECOMES EFFECTIVE ON MAY 5, 2017 Questions: If you have any questions,please contact Lina Smith at(503) 718-2438 or LinaCS@tigard-ot . --� � May 4.2017 APPROVED BY: Lina Smith Assistant Planner MMD2017-00014 TerraFirma n RECEtVED City of Tigard APR 2 6 2017 111111 . COMMUNITY DEVELOPMENT DEPARTMENT TIAEtiCdfRINGF 71GAR Minor Modification Type I Appi TIGARD Yr PROPOSAL SUMMARY (Brief description) VX'Ft,�tdc4G� �J ac-lk.FXi5T1" 1oJ%.M � REQUIRED SUBMITTAL �_JJ ELEMENTS Owner's Signature/Written Authorization Title Transfer Instrument or Deed Site Plan(2 large plans drawn to scale 1 and one reduced to 8.5"x111/2") Property / O -761.10 SW Hunz 4 ke✓ S7• %Applicant's Statement/Narrative Pro er address to tions ,� ! D 617 7�13 (2 copies)Address criteria in: TDC 18.360A50.B.1-11 Tax map and tax lot #(s): W NO$'la / Filing Fee Site size: 1 Ottaa RAA ()\11'111 I I �I. \L1 Applicant`: SC;s"tf 11.-vy sk Case No.: Ntl�lPU11— I f Address: 711(0 6,0 irkv✓lL,ar- J��• Related Case No.(s): City/state: T`► rcA- *1704435k Email: Zi frh Zip: X14 l-1(74115 .51(f (:K Tc/ • , < A•CAP vl Application Fee: Phone:514 Application accepted: Lf PROPERTY OWNER/DEED HOLDER(S)= CI Same as Applicant By: - Date: ('1 Name: 1\1‘(...- 4' C h r 4 S \i►G` L Application determined complete. /, • Address: 7400 5 W H n L:(tCi S+• By: fes. Date: 7�` �Y 19— City/state: T f G1!of 0/ p: - ,113 I:\CURPLN\Masten\land Use Applications Rev.11/24/2014 . � zip: ` / Contact name: 5 V t o-k Phone number: 503 ' S.t q ^ O S j.a =When the owner and the applicant are different people,the applicant must be the purchaser of record or a lessee in possession with written authorization from the owner or an agent of the owner.The owner(s)must sign this application in the space provided on the back of this form or submit a written authorization with this application. APPLICANT'S STATEMENT The applicant's statement must include a summary of the proposed changes. Criteria in either 18.360.050(B) or 18.330.020(B)(2) must be addressed with a detailed response to each criterion. Failure to provide the information needed to process the application would be reason to consider an application incomplete and delay review of the proposal. In addition,the Director must find that the proposed change is in compliance with all applicable requirements of Title 18 of the Tigard Development Code.To complete this review,the Applicant's proposal must include a discussion indicating how the site expansion/change will continue to comply with the maximum setback,building height,parking,and landscaping standards. Other requirements of this title such as clear vision,solid waste storage,non-conforming situations,signs,and tree removal may also be applicable depending on the type and location of the proposed modifications. City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • wwwtigard-or.gov • 503-718-2421 • Page 1 of 2 APPLICANTS To consider an application complete,you will need to submit ALL of the REQUIRED SUBMITTALELEMENTS as described on the front of this application in the"Required Submittal Elements"box. THE APPLICANT(S) SHALL CERTIFY THAT: • The above request does not violate any deed restrictions that may be attached to or imposed upon the subject property. • If the application is granted,the applicant will exercise the rights granted in accordance with the terms and subject to all the conditions and limitations of the approval. • All of the above statements and the statements in the plot plan,attachments,and exhibits transmitted herewith,are true;and the applicants so acknowledge that any permit issued,based on this application,may be revoked if it is found that any such statements are false. • The applicant has read the entire contents of the application,including the policies and criteria,and understands the requirements for approving or denying the application. SIGNATURES of each owner of the subject property required. Ale II; i 7 Applicant's signature Print name Date Owner's signature Print name Date Owner's signature Print name Date ADDITIONAL OWNER/DEED HOLDER INFORMATION Name: Name: Address: Address: City/state: Zip: City/state: Zip: Signature: Signature: MINOR MODIFICATION APPLICATION City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • www.tigard-or.gov • 503-718-2421 • Page 2 of 2 Building Permit Application • aI FOR OFFICE USE:ON1.1 City of Tigard Damn) i U 13125 SW Hull Blvd.,Tigard,OR 97223 Received Ptah Review Other Permit:1111 503,7181439 fox: 503.598.1960 R,tc!lt Permit No.: Inspection Line: 503,639.4175 Doe Iteady(Ry: orris: 6d See Page 2 for T I G i1 R.D llama trtvw.tigard•ar,gov N tiRed/Method: Supplemental information - r�.r:. �t. .,.� ..•:•:,' _ _ :•;a,=::'s;.'';n;�.:k°� - 1 b` �'�'. 1=-ifl!ID 3+;:: i:`�'= _� i_J.�U.:;'-: , ,3��j�',',x K2„�0�'*�'^�:44,t� •i.�•tr�'PE��F�����.,.1�.,�.�a v5'�:� r�`r t�'i;re n;�*:i�,`�.t m..? ,- %���.: ::::�,'�eA:,��.-.�..:_�1._... —�._;..•. _ .....e,•.� f E l New construction 0 t eriiolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all 0 Addition/alteration/replacement ❑Other: equipment,materials,labor,overhead,and the profit for the ,-i. ,,d..:1,,_ �.. 4j•+�y�.,,•,— - s r.� Tei, .+k •r• ,. ;- - z,rir` ; work indicated on this application. Valuation: S ❑ l-and 2-family dwelling ®Commercial/industrial Number of bedrooms: ❑Accessory building 0 Multi-family Number of bathrooms: 0 Master builder 0 Other: r .i - 2?= : c-777:- dVB� relMs Total number of floors: 2 r.DL , 4 l � s-_. '- Job site address,7920 SW Hunzlker St New dwelling area: square feel City/State/ZIP:Tigard,OR 97223 Garage/carport area: square feet Suite/bldg/apt.no.: Project name:Terra Firma Office Covered porch area: square feet Cross street/directions to job site: Deck area: square feel - Other structure area: square feet Subdivision: I Lot no,: Permit fees''are based on the value of the work performed, Indicate the value(rounded to the nearest dollar)of all Tait map/parcel no.:W408819 equipment,materials,labor,overhead,and the profit for tile c:1�4:;'C:-r :4si e� ,rl ;cam cii'vki'i�-' Y .:ti_ a�^�_Y-::9i'^lSz ��r� ':s=�r:'sY.c-:i.;� :1�:. :v� .rp�, r.:��'<. indicated on ,= ,, ,,� . ,�;� �-...,,:� �-�;r,,`: work This application .gip 10 t E a"vE'.„�tti:1, -•':3 ,i i' i;,t,_, ry" rf r Q. :q: __r : . &$000 -�`�.�.�-�r^.3iB .�C��'i5'1(l..i]::(..�L�:_:... it{i• rte. 2''C' !-•s... .{"�s:i� c Extending existing loading dock Valuation: Existing building arca square feet New building area: square feet — '4 e "' 71 7 �' — Number of stories y�-_f ._iia r +'� ��" .r4c.�-�r�� P1�.I�q ..,l�K..: - �'.: . Name:Ryan Beckley(TerraFirma Foundation Systems) Type of construction: Address:7920 SW H,mxiker St. OccuPantY groups: City/State/ZIP:Tigard,OR 97223 Existing: Picone:(503)4436866 Fax:(503)941-5301 New: -vt5. 74- fi _ M Sa`� � M 4x, ; :i�a=r_ '-4 �rT iiintailr yy: ir 44 rAgre ![riyllcn Business name;TerraFlrma Foundation Systems Structural plan review fee(or deposit): Contact name:Scott Ktnnlll - FLS plan review fee(if applicable): Address:7910 SW Hu nziker St. Total fees due upon application: City/StatelZlP:Tigard,OR 97223 Amount received: Phone:,(541)8174873 Fax::(503)941-5301 mss: ,. �. ::;;: :Hq R'P >iln ¢ t174 s y';.5: E-mail:skovalik@ierraflrmafs.coru - '' " '�>`:".� "'"-r`: ,`,.'„r.•: ._=4 •,ye .R.,..w.k�=s+=-W-'+<-4• <,,� .�'+s`_' 4:* yam'° rzzi.,;ri<a Commercial and residential prescriptive installation of "°= x '` • -.. .' C "Oh ' 'i-.If&`may' `'6` .A.k. t roof-topmounted Photovoltaic Solar Panel System. Business name:TerrflFirtnn FoanflatiOn Systems Submit two(2)sets of roof plan with connection details and fire department access,along with the 2010 Oircgori Address:7910 SW Hutuiker St. Solar Installation Specially Carle checklist. City/State/ZIP:Tigard,OR 97223 Permit Fee(includes plan review S180.00 and administrative fees):. Phone:(503)4436866 Fax:(503)941-5301 State surcharge(12%of permit fee): 521.60 CCB lie.:173547 • Total fee due upon application: S201.60 Authorized signature: P ''"/'y This permit application expires if a permit is not obtained �,.qr�s,� within 180 days after It has been accepted as complete. LPrint name: 1T t! Date:4-24-2017 `Fee methodology set by Tri-County Building Industry Nt� 1 /?o i CCS 1 Sri-vice Board. :tBuildrng11'cnnitslBUP-RL'SPthmilApp.doc 02/24/2011 _ � r'_ ' ill) c c i`._-. jf/.\4•,P14'/ ....O n EV 6/30/" =y ; .. j., zW i ,:,.0 noes a°e A1.a.w,nu.,�.,M x�.ca°.a r.+....•„M1.„own n.0 wn p,..x... ..O MI i t i NEW 1.001.01 .ar..,,,...ngr....,,.....,.„a..x„,11MMO.a�. J ,. ' 46' ®VICINRY MAP .,..a,.,.,.,�..m, /c� \ / • ‘-""""'".."""”"""”" le \•\\‘‘ . ,==,........„...,,,,-...-..-..,...„.,..,,,.„...,„,. ,° : �,v ��� ��� CITY OF TIGARD .,.....,„..,..°,._°,_.r._„..,..,.."......°„°°„,.... \ V% A b p rov e d b Planning °w w:"""""'"";"'"""L"`r":'""'"" ,.,,,z.r.,��...,, \ / Date: 5 �`- z 2 _,..„...47,- v\ �/ Initials/ / : i- S o € 30 ,.,,.. �. BUILDING :/c a_ .2 OJ \ „ N n_ww, .M1...°.�w n„c, .,,uon,an,u.u�m.,,.pR°..�m°.r.ue,e \ \ '• .%/tPt 1./.1.146,11,1+r...n, rws,wn.,,nm w+m.+t+-m 5 • \ % o 111-'‹ d \ g ■7 1011x°. Z/� �T�V■ 17074 ZDRAW. C1.11,00 �.. J ' ' ' DM AS/DH 1 SRE PUN T ” 11.1 04.20.2017 SIO w......--....... scar.i.a / Ev6,orn G p t rztt > o . SI .0 o. 2 mo v m Z7 Z Scott Kovalik From: David Miller <dmiller@haY 9 den-en ineers.com> R E(1 1 I �` �J ED Sent: Thursday,April 13, 2017 2:05 PM APR 2 To: Curtis McFeron 6 2G 7 Cc: Scott Kovalik CITY OF TIGARD Subject: RE: Loading Dock Extension PLANNING/ENGINEERING Scott, I'm working on getting a more correct site plan put together. Here are the answers to the City's planning questions on. 18.360.050 B. Evaluation criteria. The director shall determine that a major modification(s)will result if one or more of the following changes are proposed.There will be: 1. An increase in dwelling unit density,or lot coverage for residential development; This is not a dwelling property 2.A change in the ratio or number of different types of dwelling units; This is not a dwelling property 3.A change that requires additional on-site parking in accordance with Chapter 18.765; There is no change to onsite parking, the aerial photos shows marking for the loading dock area. These are not regular parking spots. The site has 36 existing spots. 4.A change in the type of commercial or industrial structures as defined by the Uniform Building Code; There is no change to the type of structure. 5.An increase in the height of the building(s)by more than 20%; There is no change to the structures height. 6.A change in the type and location of access ways and parking areas where off-site traffic would be affected; There is no change. 7.An increase in vehicular traffic to and from the site and the increase can be expected to exceed 100 vehicles per day; No 8.An increase in the floor area proposed for a nonresidential use by more than 10%excluding expansions under 5,000 square feet; There is no change. 9. A reduction in the area reserved for common open space and/or usable open space which reduces the open space area below the minimum required by this code or reduces the open space area by more than 10%; There is no change. 10.A reduction of project amenities below the minimum established by this code or by more than 10%where specified in the site plan: a.Recreational facilities; Th ere is no change. b. Screening;and/or There is no change. c. Landscaping provisions. Th ere is no change. 1 11.A modification to the conditions imposed at the time of site development review approval which are not the subject of paragraphs No. David Miller I Senior Structural Drafter HAYDEN ENGINEERS STRUCTURAL I CIVIL From:Curtis McFeron Sent:Wednesday,April 12,2017 4:17 PM To: David Miller<dmiller@hayden-engineers.com> Subject: FW: Loading Dock Extension Can you provide whatever it is the City of Tigard is requesting? Curtis McFeron Hayden Consulting Engineers (503) 968-9994 ph From: Scott Kovalik [mailto:SKovalik@terrafirmafs.com] Sent: Wednesday, April 12, 2017 4:06 PM To: Curtis McFeron Subject: RE: Loading Dock Extension Hello Curtis, They just want the 11 items with the arrow next to them on section B, and a site plan to scale showing setbacks from property lines to the loading dock. This is for the planning permit prior to applying for the building permit. Thanks, Scott Kovalik — North Logistics Coordinator TERRAFIRMA FOUNDATION SYSTEMS 7910 SW Hunziker St. I Tigard, OR 197223 (503) 443-6866 I (503)941-5301 FAX I (541)492-2431 DIR I (541)817-4873 CELL 11 TOP WORK PLACES t7,hc(1)tc¢onian . • 2 55.5.2p5 N • h• .111./ NtISp Wading Rapids ''‘;'0 NW on On.norAO \Som R bM p El EXP: 6/30/17 G IRM.-°el Ww - o Tr >_ GENERAL NOM Iia w J i y u 0 DESIGN STANDARD .20140(0000 SRUC1111AL SPECIALTY CODE ).Z = O P N /P{ d , U Li C SCOPE Of TIER TM SCOPE OF WOR PERTAINS 1011E WEND OF DEWI ENG 11.11.110.DTONING DOCK ZZ ' 62 CENRAL ` F Lk, •a c I. SPECIFICATIONS AND CODES REFERENCED NTIESE HORS ARE TIE VERSIONS MOST RECENTLY ADOPTED NINE PRMIMG AUTHORITY 0 pppppp..,.. 0 7. L KRE10N PRIM0EDCOEMUOf PRMIN AIRIES 2ll WAS RLDVFR51 DMD.11.01 *EV Of DINNTRACOREDDSML Ibisl,C�.y0 n O SWUM PRIOtNOIAMICNIONO AMR DE D.All DNENWMANIIENP MO BEVAI NS CLESIS TO RR DEM _ppp 22c N0RE0WMF1. OPIn5.1.• C. S 5 . ITI `� ]. APPLY.51ACE ERECT OR INV..PRODUCE ANDMAIRMU N ACCORDANCE MID,MDMJACRRRS161R4CISM. •_ O Y; 1. ALL WEAMERN00.0I PUHA PROTECTION RAUSE IT OTROSs NF1 S. ALL TEMPORARY SNORING SMALL N IT OTTERS. \ PROLCT 114A FOUNDATIONS / I FO \\ - LOCATION / \ &DA1pNCRIEHA \ \ ALLOWOIIF SOEIEARNG PRESSURE 1550551 \\\ \ 2 PIACI FOO1Ncs 0214 MIN.MIRED IcoMPACAO ROCK RE / \ \ 1. MOM PLACEMENT O CONCRETE.REMOVE ALL 068111IFDSOI ROMFOOING gCAVAMNI. / \ <AANfLACE CONCRETE / \ \\ P •\ \ I. ALL CONCRETE WORE SHALL CONFORM TO ACI 301. \ 2 PREPARE MEe FOR EACNME OF CONCRETE. NEW POR1pNOP \ \\ SN a PROPOR1APES ITREIN MIOIAIOET NWIAICH OR FEB gEEREIEC5 METHODS MING MATERIALS.N IAL9EP/RIOTED ON THE LOADPOG ' \ \\ WORD FOR EACH CLASS OfCONCRETE RE01BED AS SPECIE N AG TRI. \ Is CHMiLL M AED WORTS SIE N• RD FOR EACH PROPOAO MCH l FOt EAME Of WON Of DP SECTION. c.CONAACIOI...MP CONCRETE MI DESIGNS ALONG%TNMT DATA FOR A MMM OF PR WAD OA]A MINIM O I]7 , 5 \\ ®VICINITY MAP MIS PRIOR 10 1.<114 CONCRETE. \ \ \ Nls ACT0000 GAG&INACCODMCE WM ASIMCRIOAM WAIEPEEOUCMG ADMMRES CONFORMING TO MINN1Law N / .\ \\ / ERICA ACCORDANCE INN OE ANTRACIIRERS RECOMMMADONI MAY BE 015151 RATED M CONGER DESIGN MOS. / $ \ b.ANMBTUDI•IG AG&TC0MO1ANG TO AAM CIBMALL BE WED II CONCRETE WS FOR EISRIOR HORONIAL SURFACES ' \/ TO REAMER. ENTRAINED EM.BE aFFf�ANDSHALL CONFORM TO A�M�AM MML�IIMIED TOGA IS%TM/3MM IT CEMENT WEIGHT / TERRAFIRMABUILDING %4�! \\ E. USE PORTLAND GEMINI TYPE IOR R CORORMMEIH AAM C ISO.SUNYEIOMOE IIT SOURCE. // `l \\ \ \ S. AGGREGATES PALL CONFORM MN ASTM C 33 AND RE INOROUGN.9 CLEANED AM WAR.PRIOR.LSE \ K CONCRETE SIIl11GW611WLN AS fp LOWS. / \ \\\\ Tc=1 _000 PSI AT Ie DAYS FOR 2500 PER. ~[\ \\ b.SUIS: Ic 4 AMIN AT a DAR(OFSIGNFO FORT RD RR R7 \ a WAIU: to 1010111AT ID DAYS(OEAGNED FOR 2500 PST. \ \\ I. MAXIM.SLUMP FOR cOSKREO(mum 4^nus01 M1US l°. \ / IL NO WAIF.SIMV M ADDED ID ME CONCRETE O11ER MAN MAI REOUE IT THE M DESIGN APPROVED IT 1F.Noe.of RECON. 13 \ \ \\\ / 9. 8111005.OPENNGS.C0(010 AND OMR EMEDDED REM N0I SHOWN ON DE STRUCTURAL 052084G51HALL N APPROVED N THE `1■Y■ / FNGN[RORKORD TROP TO POUMG. \ \\\ 10. COMDR EMEDED N SUNS SHALL NOT N URGER MAN II IAO IR SWIHCDNW AND SHALL NOT IE SPACED CLOSER..151 \ \\ / DIAMETERS ON CENTER \\ \ \\\ / / 11. PROVEN IV OMBRERS ON ALL FWOSED CONCRETE EDGES UNLESS HOOD ONBMN. CITY OF TIGARD CONCRETE RBIOICNG SED: \ / \ \ / z I. RBEWCNGSOELAMLLIFODMMOEA6COMORMIGIOAMA ANS.GRADE WURESSN01W011FM6E. \ �' / Approved by PI nning ° / ^(J Z W N 7. 1BEOICNG STEEL SHALL IF DEEMED.ACCORDANCE MINDS WEST WPM Of DE A<S115'DEIMSMo MARINO CONCRETE \ / ' ' /� W I-1� IFKOfCEAENP. \ / / • //// h O, ate: • • X ]. REIEORCNG STEEL SHALL 51001110 fOLLOVMGPROTECMF ttFMMCFI: / 1 {... W W Z a CONCRETE CAA AGANSI AND'FERMATE/PEI DPOSFD TO EAERt \\ j C LS • Y Y O i ALL RIMORCIIG SEE r / Initials• V Z w b.CONCRETE ESPOSF1IOEMMAr50 NEARER: O i PSIAP,VOI OR DSI PORE AND SMAUR, r / �1 T.NITER*ROUGH MEM: T \ a APS=O a CONCRETE NOT gPOSED TO MAHER OR.CONROY.IH MRMc V STAG WAII3.AM SOME / / O L Z 3 Q 2 tU 1M AND IMAM. %. \ / it 0 N ce E RAM AM(lI12 \ EXISTING / / Ce O Q O< I. WART1 CEPOIT5T: TI BUILDING / / 11 N O P \ / / H J H E. UNLESS NOTED ORERNRE ALI RRIFORCfMPM LAP SPLICES SHALL IE M FOLLOWS'. ' / MIP YE M lf,1504PIE SPLICE11poD59 \•::.;.;:e '6 / / u• n \ /1 / P1 ]r' 31' \ PS 3r / Pe r Y' ' Pe ro• \ / a.THESE LENGTMAI APPLY 010 U1C1AIFDD MNE REINFORCING SONOR MAL WWOWCONCRETE.CUM SPACNG REINE& NOT / LESS N 1211AR DIAAEI95DS AND CLEAR COW NOT LESS MLIGHTWEIGHT 111101 DIAMETER.FOR HGHT CONCRETE 0I REDUCED \ / / SPACING/COVER.AIMTRY LENGTHS IT 1.1 b FOR TOP IAB RIMS WIMP RE MM MOIr O FRESH CONCRETE CMT.LOW IR .ERL IA.1 I LENGTHS ISP I S. \ % W / MSR S 1Ab/e1D E: 25101C10020D 0 SPFCML NSPFCTON6 \ / / / Red Nowt,/Account P: RI56090 I. MOILINPFCIIOD 54141 N PERFORMED PER 0411101 IR OREGON SRUCORM SPECIALTY CODE FOR ME FOLLO0NO: \ / / SEI A1DIIU: 7920 SW HUNDKER RD.TIGARD DR.97713 Z REM a.CONCRETE PLACEMENT b.SMSON SETH.'ACMES.PER IOC REPORT 131-23(a \ /'J' J Z / O W CI- \ / / S LLI H R E CE I V \cI/ 0 V, \ ,, 17074 DRAWN CHECKED ® SITE PLAN APR 26 2017 DDATE M AS01 ERN qMA_RASEIWG E 1.•e0d 04.20.2017 REVISIONS CITY OF TIGARD PLANNING/ENGINEERING E`, SHEET1 R S1 .0o02 • av ,6GINE /, •'7'' .. nom . EXP: 6/30/17 Zy�yr ' ' YV P w Ww ' 5ZE 0,, a _z6 W N W e -a( W pp< R) P 3. eh SIM. §_ ITI _L L 3 H /fC01K.5LA6 W! f P 2 R40ITOfC FA WAY �..� HFM CSN VON I--I11.111 N5� — I 9 S20 i G c ' Q ON D REAP 1P.`t17 L IT IL FV DOCK FTbKNI J 120 EX 49-. WHO 100-0t ® PARTIAL PLAN scAle 3r:=ra Z O,_ 37' CONC.SLAB,PER PLAN 94 DOWELS 0 12'0/C 6 32'MIN.LAP Z LLJ w CA DO 3714 DOWELS 017'0/C / W/4"EMBED INTO EMI.SLAB SLAB DOWELS,PER 1.1.1 I— II/( USING SIMPSON SET-HP'ADHESIVE . 2/52.0 x H(/. R4 CONTAT EDGE w Z MATCH EXIST.M. ' / Y Y 0(3,6'il _ - �_ U C/ imion U LLJ O z w . • Z'O E(2)N CONT.AT TOP J/ ce 6"CONC.WALLW/#4 ''�f -.• O L O @IT'O/C EA.WAY AVERT. - -._ Q Q CENTERED IN WALL) - EXIST.CONC. o—0 "NO SPLICES IN NERTS! ' ' '" H OJ f\I— HOOKED N FOOTING•• i,0-+ NEW STRUCTURAL WALL PANEL // ALL COMPACTED TO 95% N�.' OF PROCTOR EXIST.PAVING, EXBT.PAVING, }'1'. - --- REMOVE/REPLACE REMOVE � , ' _e AS REO'D s r i10 36'0/C AS REGI'D ti`' —EXBT.CONC. WAIL PANEL 2'-0'UP,WP, t r� _ .: CONTNOUS AT EV92Y • r X4)04 COM. THROBAR Id- / -�- SAWCUI I'DEEP �/DBCONiNUE RERIF. MN. 04 CONT. r r 1,0' I J YCL • ' \I .ii. �I '1, csfi tfi vS ciAT',fe-PAI � iii in CRUSHED/COMPACTED - 1'-0" • STRUCTURAL FM PER 2/2A GRAVEL BASE f4 DOWELS TO MATCH HORD.RHNF. t£ ---\ W/4-EMBED INTO EXBT.SLAB 0 Z 3.q,. USING SIMPSON'SRI-XP'ADHESIVE r Q / / T J h LL 2 SECTION 3 SECTION 4 CONTROL JOINT S2.0 ,F,.,.F,Id.-....0 SCALE%,-1-0 52 •.0 at.rm.-lAiUw SCALE:C"•1'-O 52.0 11,1^•row._'•4•O." SCALE:57=1'47 JOB N0 17074 DRAWN CHECKED DM AS/DH DATE 04.20.2017 REVISIONS • a P ii SHED S2.00F2 V