Loading...
Permit (69) 1 CITY OF TIGARD MASTER PERMIT II.. ` COMMUNITY DEVELOPMENT Permit#: MST2017-00161 Date Issued: 05/15/2017 T[G 1, P 0 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 2S109AB00600 Jurisdiction: Tigard Site address: 14031 SW ALPINE CREST WAY Subdivision: None Lot: None Project: OTIS Project Description: Solar photovoltaic system. Electrical permit applied for: ELC2017-00319 BUILDING Floor Areas Required Setbacks Required Stories: Bedrooms: First: sf Basement: sf Left: Parking Spaces: Height: Bathrooms: Second: sf Garage: sf Front: Smoke Right: Detectors: Dwelling Units: Third: sf Ri 9 Total: sf Value: $0.00 Rear: PLUMBING Sinks: Water Closets: Washing Mach: Laundry Trays: Rain Drain: Urinals: Lavatories: Dishwashers: Floor Drains: Sewer Lines: SF Rain Storm Sewer: Tubs/Showers: Garbage Disp: Water Heaters: Water Lines: Drains: Catch Basins: Bckflw Prevntr: Footing Drain: Ice Maker: Hose Bib: Backwater Value: Other Fixtures: Drywell-Trench Drain: Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: Clothes Dryers: Heat Pump: N Hoods: Other Units: Furn<100K: Vents: Woodstoves: Gas Outlets: Furn>=100K: ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'I 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: N Other Description: Roof top PV system Ecompasing: N BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: ALT SF VB R-3 Owner: Contractor: OTIS,BRIAN D&LORRAINE M Required Items and Reports(Conditions) 14031 SW ALPINE CREST WAY TIGARD,OR 97224 PHONE: PHONE: FAX: Total Fees: $428.48 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may o in-e-copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. A.,'" „� ('fes Issued By:/ 1 / )) Permittee Signature: C,��. .---Q- 4:77 �en" (.. Call 503.639.4176 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Application Residential ,1 FOR 011 1( 1: 1 51:(l.I.) City of Tigard4. Received ,Rece v �/I! Permit No.: ,M r �,,/ 7 13125 SW Hall Blvd.,Tigard,OR 972>ib riN1 Plan Review,........... �Gi9. v ' ■ Phone: 503.718.2439 Fax: 503.598.1'"t t- Date/By: -)'� Otter Permit: t �.. ,�1 2-i _ I,n Inspection Line: 503.639.4175 �N`� Kyo II a Ready/By: /// Juris: See Page 2 for Internet: www.tigard-or.gov ',,l ..ed/Method: 3 /i' f 7 7.--c,,,, Supplemental Information 0 New construction o De ition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ®Addition/alteration/replacement ❑Other: equ•ipment,materials,labor,overhead,and the profit for the r" work indicated on this application. .„ Valuation: $ ®1-and 2-family dwelling 0 Commercial/industrial ❑Accessory building 0 Multi-family Number of bedrooms: ❑Master builder 0 Other Number of bathrooms: ` tookv as ;:n 4 s , ft a . Total number of floors: Itt,f„'4•-1,7 "-,;,••,4:41'.:,"!_-•.,:,41.:47•; 1 4. _" ....,.»m.: a .. ... ..^,...w.�. a ., o-'fi.,.4� _ :%�t. Job site address:14031 SW ALPINE CREST WAY New dwelling area: square feet City/State/ZIP:TIGARD OR 97224 Garage/carport area: square feet Suite/bldgJapt.no.: Project name:OTIS RESIDENCE Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet Subdivision: Lot no.: Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all Tax map/parcel no.: equipment,materials,labor,overhead,and the profit for the reit- .y z�...."r- .fir-ter` °, ,,� ...,.,<s -fir.. g... ), ?-_ ' _,,,,,,,_,,,,44r_._,,,.. ..„. �` ,s i,,,<r',.` PW � work indicated on this application. ADD 16.2 KW ROOFTOP__-- PV SY�SSSTEM Valuation: $ /�iez-Tri GO- i T G'f�t . i J[5..6`4-4 Facisdng building area: square feet / -+'rte,, f, New building area: square feet I t a � 7 _, s , - -, Number of stories: Name:BRIAN OTIS Type of construction: Address:14031 SW ALPINE CREST WAY Occupancy y groups: City/State/ZIP:TIGARD OR 97224 Existing: Phone:(503)504-2185 Fax:( ) New: Business name:PREMIER ENERGY,INC Structural plan review fee(or deposit): Contact name:DAN TRACY FLS plan review fee(if applicable): Address:556 SOMMERSET ROAD City/State/ZIP:WOODLAND WA 98674 Total fees due upon application: Phone:(503)828-9500 ( Fax::(503)410.7110 Amount received :..>.- ,, �z �r E-mail:rltl a remiersoiarnw tom . s ' ;,*s ' i ,,, s - � � � , � Commercial and residential prescriptive installation of 4.' ., }ass t l .z tit 4 , :� h , roof-top mounted Photo Voltaic Solar Panel System Business name:PREMIER ENERGY,INC Submit two(2)sets of roof plan with connection details and fire department access,along with the 2010 Oregon Address:556 SOMMERSET ROAD Solar Installation Specialty Code checklist. City/State/ZIP:WOODLAND WA 98674 Permit Fee(includes plan review $180.00 and administrative fees): Phone:(503)828-9500 Fax:(503)410-7110 State surcharge(12%of permit fee): $21.60 CCB lie.:195595 Total fee due upon application: $201.60 Thispermit applicationexpires if a permit is not obtained Authorized signs�Te�� PP Ji& e„,.....-- within 180 days after it has been accepted as complete. *Fee methodology set by Tri-County Building Industry Paint name:DANIEL'TRACY Date:4-26-2017 Service Board. I:Building\Permits\BUP-RESPermitApp.doc 02124/2011 440-4613T(11/02/COM/WEB) City of Tigard '' Building Division ' • 13125 SW Hall Blvd,Tigard, OR 97223 RECEIVED Phone: 503.718.2439 Fax: 503.598.1960 TIGARD Inspection Line: 503.639.4175 MAY 3 2017 www.tigard-or.gov CITY OF TIGARD SUILDING DIVISION 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: 14031 SW ALPINE CREST WAY City: TIGARD Zip: 97224 Owner's Name: BRIAN OTIS Date: 4-26-2017 Contractor's Name: PREMIER ENERGY, INC CCB #: 195595 Design Parameters of the Property/Structure If"Yes",does not Flood Hazard Is the installation E] Yes qualify for the Area Located in a flood prescriptive path, follow plain/flood way? ® No OSSC or ORSC for design requirements. 1 Yes Is the wind exposure If"Yes",quali Wind Exposure fies for "C"or less? (J No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes", qualifies for family townhomes ® Yes the prescriptive path. and/or their accessory Ground structures. ❑ No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? structures other than If"Yes",qualifies for ® Yes the prescriptive path. above ❑ No 1 I:Building/Forms/PhotoVoltaic-Checklist.docx Is the construction IZ material wood and does Yes Type of the construction qualify If"Yes",qualifies for Construction as "conventional light ❑ No the prescriptive path. frame"construction? Is the spacing 24 inches or less? If"Yes",qualifies for Pre-engineered trusses. ® Yes the prescriptive path. ❑ No Roof framing members Is the spacing 24 inches or less? Nominal lumber. If"Yes",qualifies for ® Yes the prescriptive path. ❑ No Is the combined weight ® Yes of the PV modules and If"Yes",qualifies for racking less than or ❑ No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation layout in accordance Yes with Section 305.4(3)of If"Yes",qualifies for the 2010 Oregon Solar ❑ No the prescriptive path. Code? ❑ Metal Single layer If roofing material is Roofing Check the type of 0 of wood one of the three types material roofing material shingle/shake checked,qualifies for Max. two layers the prescriptive path. 1 of composition shingle. Is the roof mounted ® Yes Connections of solar assembly the solar assembly connected to roof If"Yes",qualifies for ❑ No the prescriptive path. to the roof framing or blocking directly? 2 I:Building/Forms/PhotoVoltaic-Checklist_docx ❑ Yes If"Yes",qualifies for Is the gauge 26 or less? ❑ No the prescriptive path. / 115 lbs for 60 inch spacing or less? If"Yes",qualifies for ❑ Yes the prescriptive path. ❑ No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If"Yes",qualifies for ❑ Yes / the prescriptive path. ❑ No Attachment of roof mounted If the spacing falls solar systems Spacing of clamps? Minimum 24 inches within 24 inches and 60 directly to inches Maximum 60 inches inches,qualifies for the standing seam prescriptive path. metal panels Width of roofing If the width of the panel panels? ,x'18 inches or less is less than 18 inches, qualifies for the inches ,,F'' prescriptive path. {,/ Minimum#10 at 24 inches o/c? Size and spacingr`of If"Yes",qualifies for fastener? ❑ Yes the prescriptive path. ❑ No Is the roof decking of WSP men. 1/2"thickness, ❑ Yes dec ng connected to If"Yes",qualifies for aming members ❑ No the prescriptive path. w/min. 8d nails @ • 6"/12"o/c? ,. Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes",qualifies for solar modules module to the roof ® Yes the prescriptive path. surface. ❑ No 3 I:Building/Forms/PhotoVoltaic-Checklistdocx Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines, and, as applicable,flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing(rafter size,type, and spacing) and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer: SOLARWORLD Model Number: SW300 Listing Agency: UL 4 I:Building/Forms/PhotoVoltaic-Checklist.docx