Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report
1c2c'/?- 0&2-4> 7&?(i 5AlC6 W 50VT—C Comfort' 14 SEER Single—Packaged Heat Pump CCarrie-ID System with Puron® (R-410A) Refrigerant Single Phase 2-5 Nominal Tons (Sizes 24-60) Three Phase 3-5 Nominal Tons (Sizes 36-60) turn to the experts Product Data Durable,dependable components aag �»jj)�)) Scroll Compressors are designed for high efficiency. Each l\\ l\� compressor is hermetically sealed against contamination to help promote longer life and dependable operation. Each compressor _ also has vibration isolation to provide quieter operation. All compressors have internal high pressure and overcurrent _- protection. ECM Motor is standard on all models. Direct-drive, PSC (Permanent Split Capacitor)condenser-fan motors are designed to help reduce energy consumption and provide for cooling operation down to 40°F(4.4°C)outdoor temperature.Motormaster® II low ambient kit is available as a field installed accessory. 'Ii Innovative Unit Base Design On the inside a high-tech composite material will not rust and . 0incorporates a sloped drain pan which improves drainage and helps 1 inhibit mold,algae and bacterial growth.On the outside metal base 111[. c: rails provide added stability as well as easier handling and rigging. 0 O O Thermostat Controls designed to work as a system with Carrier's small packaged product. A09034 Refrigerant system is designed to provide dependability. Liquid Fig.1- Unit 50VT-C filter driers are used to promote clean,unrestricted operation.Each Single-Packaged Products with Energy-Saving Features and unit leaves the factory with a full refrigerant charge. Refrigerant Puron RO refrigerant. service connections make checking operating pressures easier. • Up to 14.5 SEER High and Low Pressure Switches provide added reliability for the • Up to 12.0 EER compressor. • 8.0 HSPF Indoor and Outdoor coils are computer-designed for optimum • ECM Motor-Standard heat transfer and efficiency. The indoor coil is fabricated from •Certified to leak 2%or less of nominal air conditioning CFM deliv- copper tube and aluminum fins and is located inside the unit for ered when pressurized to 1-in.W.C.with all present air inlets,air out- protection against damage.The outdoor coil is internally mounted lets,and condensate drain port(s)sealed. on the top tier of the unit. FEATURES/BENEFITS Low sound ratings ensure a quiet indoor and outdoor One-piece Heat Pump unit with optional electric heater, low environment with sound ratings as low as 73dBA. installation cost,dependable performance and easy maintenance. Easy to service cabinets provide easy 3 panel accessibility to serviceable components during maintenance and installation. The Efficient operation High-efficiency design with SEERS (Seasonal Energy Efficiency Ratio)of up to 14.5. base with integrated drain pan provides easy ground level installation with mounting pad. A nesting feature ensures a Puron Environmentally Sound Refrigerant is Carrier's unique positive basepan to roof curb seal when the unit is roof mounted.A refrigerant designed to help protect the environment. Puron is an convenient 3/4-in. wide perimeter flange makes frame mounting HFC refrigerant which does not contain chlorine that can harm the on a rooftop easy. ozone layer.Puron refrigerant is in service in millions of systems, proving highly reliable,environmentally sound performance. Convertible duct configuration Easy Installation Unit is designed for use in either downflow or horizontal i applications. Each unit is converted from horizontal to downflow Factory-assembled package is a compact, fully self-contained, with the two standard duct covers. Downflow operation is easily sr heat pump unit that is prewired, pre-piped, and pre-charged for provided in the field to allow vertical ductwork connections. The minimum installation expense. These units are available in a basepan utilizes seals on the bottom openings to ensure a positive variety of standard capacity ranges with voltage options to meet seal in the vertical airflow mode. residential and light commercial requirements. Units are lightweight and install easily on a rooftop or at ground level.The Cabinets are constructed of heavyduty, phosphated, zinc-coated high tech composite base eliminates rust problems associated with prepainted steel capable of withstanding 500 hours in salt spray. ground level applications. Interior surfaces of the evaporator and electric heater compartments are insulated with cleanable semi-rigid insulation board, which keeps the conditioned air from being affected by the outdoor ambient temperature and provides improved indoor air quality. (Conforms to American Society of Heating,Refrigeration and Air 1 t T , Conditioning Engineers No.62P.)The sloped drain pan minimizes standing water in the drain.An external drain is provided. Short-Cycling protection for the compressor is incorporated into our defrost control board ensuring a five minute delay (+/-2 minutes) before restarting compressor after shutdown for any reason. TABLE OF CONTENTS FEATURES/BENEFITS 1 MODEL NUMBER NOMENCLATURE 2 AHRI CAPACITIES 3 PHYSICAL DATA 4 OPTIONS AND ACCESSORIES 5 ROOF CURB ACCESSORY DIMENSIONS 6 BASE UNIT DIMENSIONS 7-8 U SELECTION PROCEDURE 10 PERFORMANCE DATA 11-24 TYPICAL PIPING AND WIRING 25 APPLICATION DATA 26 ELECTRICAL DATA 28 TYPICAL WIRING SCHEMATICS 30-35 CONTROLS 36 GUIDE SPECIFICATIONS 37-38 MODEL NUMBER NOMENCLATURE 50VT — C 24 --- 3 1 -- Type of Unit Options 50VT—Single Packaged Heat Pump LT— 2%air leakage,tin plated indoor coil hairpins System and louver metal outdoor grille. TP—Base unit with tin plated indoor coil hairpins (Single Phase Only) N/A See Price Page for full list of factory options. Only used if ordering an option Major Series Nominal Cooling Capacity 24—2.0 Tons Minor Series 30—2.5 Tons 36—3.0 Tons 42—3.5 Tons 48—4.0 Tons 60—5.0 Tons Electrical Supply 3—208/230-1-60 5—208/230-3-60 6—460-3-60 N/A rumsu_loi CERTIFIED Use of the AHRI Certified � A IE C oL US TM Mark indicates a manufacturer's COMPLIANT LISTED participation in the program For verification of certification for individual products,go to www.ahridirectory.org. 2 AHRI* CAPACITIES COOLING CAPACITIES AND EFFICIENCIES UNIT NOMINAL TONS STANDARD CFM COOLING CAPACITY EER SEER 24 2 800 23000 12.0 14.5 30 2.5 1000 28600 11.5 14.0 36 3 1200 34200 11.5 14.0 - 42 3.5 1400 41000 11.5 14.0 48 4 1600 48000 12.0 14.0 60 5 1750 57500 11.5 14.0 HEAT PUMP HEATING CAPACITIES AND EFFICIENCIES HEATING CAPACITY(BTUH)@ COP @ 47°F HEATING CAPACITY(BTUH)@ COP @ 17°F UNIT47°F(8.3°C) (8.3°C) 17°F(-8.3°C) (-8.3°C) HSPF 24 22600 3.7 12000 2.30 8.0 30 28400 3.7 15600 2.35 8.0 36 34400 3.6 18600 2.30 8.0 V 42 40000 3.6 22600 2.40 8.0 1 48 46000 3.6 25800 2.40 8.0 j 60 57500 3.7 33000 2.45 8.0 0 U, LEGEND Notes: dB-Sound Levels(decibels) 1. Ratings are net values,reflecting the effects of circulating fan heat. db-Dry Bulb Ratings are based on: SEER-Seasonal Energy Efficiency Ratio Cooling Standard:80°F(26.7°C) db,67°F(19.4°C)wb indoor entering- wb-Wet Bulb air temperature and 95°F(35°C)db outdoor entering-air temperature. COP-Coefficient of Performance 2. Before purchasing this appliance,read important energy cost and effi- HSPF-Heating Season Performance Factor ciency information available from your retailer. *Air Conditioning,Heating&Refrigeration Institute. **At"A"conditions-80°F(26.7°C) indoor db/67°F(19.4°C)indoor wb& 95°F(35°C)outdoor db. t Rated in accordance with U.S.Government DOE Department of Energy) test procedures and/or AHRI Standards 210/240. 11 I 3 , • PHYSICAL DATA 24 30 36 42 a6 60 Unit Size 2 2.5 3 3.5 4 5 Shipping Weight(Ib) 365 395 440 475 500 515 (kg) 166 179 200 215 227 234 Compressor Quantity 1 Type Scroll Refrigerant R-410A Refrigerant Quantity(Ib) 7.5 9.0 8.9 11.2 9.9 11.9 Quantity(kg) 3.4 4.1 4.0 5.1 4.5 5.4 Indoor Ac- - curater, Indoor TXV,Out- Refrigerant Metering Device Indoor TXV,Outdoor Dual Accuraters Outdoor door Dual Ac- Dual Ac- curaters curaters Orifice ID(in) N/A 0.080(1) N/A (mm) 2.03(1) Orifice OD(in) 0.032(2) 0.035(2) 0.040(2) 0.046(2) 0.046(2) 0.052(2) (mm) 0.81 (2) 0.89(2) 1.02(2) 1.17(2) 1.17(2) 1.32(2) Outdoor Coil Rows...Fins/in, 1..21 1..21 1..21 1..21 1..21 2...21 U face area(sq.ft.) 15.4 18.8 17.5 23.3 23.3 17.5 I Outdoor Fan Nominal Airflow(cfm) 2500 3000 3600 4000 4000 3800 o Diameter(in.) 24 24 26 26 26 26 u7 Diameter(mm) 610 610 660 660 660 660 Motor hp(rpm) 1/12(810) 1/10(810) 1/5(810) 1/5(810) 1/5(810) 1/4(810) Indoor Coil Rows...Fins/In, 3...17 3...17 2...15 3...17 3...17 3...17 face area(sq.ft.) 3.7 3.7 5.6 4.7 4.7 5.6 indoor Blower Nominal Airflow(cfm) 800 1000 1200 1350 1600 1750 Size(in.) 10x10 10x10 11x10 11x10 11x10 11x10 Size(mm) 254 x 254 254 x 254 279 x 254 279 x 254 279 x 254 279 x 254 Motor hp(rpm) 1/2 1/2 1/2 1/2 1 1 High Pressure Switch(psig) Cutout 650+/-15 Reset(Auto) 420+/-25 Loss-of-Charge/Low Pressure Switch(psig) Cutout 20+/-5 Reset(Auto) 45+/-10 Return Air Filters 1 each 24x16x1 in. 1 each 24x14x1 in. 1 each 24x16x1 in. disposable 2 each 20x12x1in. 610x406x25 mm 610x356x25 mm 610x406x25 mm 508x305x25 mm 24x18x1 in. 24x16x1 in. 24x18x1 in. 610x457x25 mm 610x406x25 mm 610x457x25 mm *Required filter sizes shown are based on the larger of the AHRI(Air Conditioning Heating and Refrigeration Institute)rated cooling airflow or the heating airflow velocity of 300-350 ft/minute for throwaway type or 450 ft/minute for high-capacity type.Air filter pressure drop for non-standard filters must not exceed 0.08 - IN.W.C. t If using accessory filter rack refer to the filter rack installation instructions for correct filter size and quantity. A-WEIGHTED SOUND POWER LEVEL(dBA) UNIT SIZE STANDARD TYPICAL OCTAVE BAND SPECTRUM(dBA without tone adjustment) RATING(dBA) 125 250 500 1000 2000 4000 8000 24 74 55.1 54.3 56.7 54.9 51.7 47.2 42.9 30 75 52.7 53.0 57.9 58.7 54.8 52.2 43.2 36 74 61.9 63.3 58.9 59.9 58.7 56.2 52.4 42 73 52.7 56.9 61.5 60.7 56.7 54.1 47.9 48 74 _ 57.4 57.1 60.9 63.2 57.8 54.8 46.1 60 75 59.3 62.2 62.1 64.1 59.4 55.8 50.2 NOTE:Tested in accordance with AHRI Standard 270-1995(not listed in AHRI). Ilb .. 4 ECONOMIZER HVAC Unit Compressor Cover Replacement Panel Shipped with Economizer COIL ��i:�' ` NOTE:On units with base �`�� � rails this compressor ``==�, cover is shipped with the ' ��II�Iif III�II�IIIIII:111111 IIIIIIII����� HVAC unit. FILTER I I I I I I 11111111 1111111 I I I I Chamlber Panel Shipped with Economizer 1T ECONOMIZER 0 ,,'' 4 1 7 4 , . CAULK BOTTOM CORNER / Hood C in OF ECONOMIZER SIDE VIEW ON EACH SIDE . FILTER Vertical Economizer COIL ECONOMIZER <iii111111111 Filter Door giL.:1I/ 'eloZ%AReplacement BASE �'� Panel �FLANGE IIIIIIIIIIII101 IIII� � Economizer ON BASE DETAIL IIIIIIIIIII' IIIIIIIII1II� /� Economizer rommetfor Wir ng PI __ 01 h,,,,05,...1 _ FILTER RACK „4„1.,q BEND FLANGE AT 90-SCREW TO �" DIVIDER WITH 1-IN.(25mm)SCREW �'l% Horizontal Economizer TOP FILTER RACK �r� �^ EVAPORATOR �9 COIL r'�f�f ��� MANUAL OUTSIDE AIR DAMPER I r� PANEL rir r �ir � �-fir:-,I::, � • MANUAL OUTSIDE � �r����^ AIR HOOD � �r�r!�r 7.....'.%,,:.".."',7--- / DAMPER I !b:IH1!Jhi _ BLADErrr o �� 1 �r �� BOTTOM FILTERl ii RACK o o i ' r At 411 . A09375 6 c N 9 z 11 - UNIT ELECTRICAL UNIT W1. UNIT HEIGHT IN/MM CENTER OF GRAVITY IN/MM F.1 CHARACTERISTICS LB KG _ 'A' N I 2 M.4 5081-C24---30 208/230.1.60 311 141.0 47-3/4 1213 20-1/2 521 15-1/2 394 16-1/2 119 4 i 5001-C30---30 208/230-1-60 351 159.2 51-3/4 1315 20-1/2 521 151/2 394 16-1/2 419 NNN���yyy UNIT VOLTAGE CORNER WEIGHT LB/KG " 'I' Z 9-15/16•.-21-9/16-., 9.15/16-0-- 24 208/230 46.7 21.2 62.2 28.2 93.3 42.3 108.9 49.4 1251.1] [517.7] 1152.11 30 208/230.52.7 23.9 70.2 31.8 105.3 47.8 122.9 55.7 I.�y 3-7/16 81.3] * O 11111 Z 2-3/4 RETURN SUPPLY CA 169.9110 111o 1 J; S .- .-51Ni 1 1 1 'OPTIONAL K OPTIONAL pECA� 10 CpB61HE MAI- RETURN - SUPPLY 15-15/16 AIR AIR INCHES[MM] W [101.81 OPENING - /'ENING TOP OF UNIT II 1355.61 C) DUCT SIDf OF UNIT 2 150.81 �(j i SIDE OPPOSITE DUCTS I/1355.61 •,;.-10 I ill ELECTRICALUNIT 0 PANEL 36 1914,11 U EB. -CUJEAFIIB OUTDOOR COIL) .Y, F� ' F. INCHES IMM] BETWEEN UNITS,POWER ENTRY SIDE 42 11066.8] t./14M-T• 1 • • To UNIT AND UNGROUNDED SURFACES,POWER ENTRY SIDE 36 1914.0] �- UNIT AND BLOCK OR CONCRETE WALLS AND OTHER /Jr 01086010 SURFACES,POWER ENTRY SIDE 42 11066.8] / * 112 1®181 QF.ARAFLE FOR ROM=N SERW 1G _f INCHES IMM] INDOOR COIL UTDOOR COIL EVAP.COIL ACCESS SIDE 36 1914.0] TOP VIEW P09CR ENTRY SIDE 42 11066.81 (EXCEPT FOR NEC REOUIREMENTSI UNIT TOP 48 11219.21 SIDE OPPOSITE DUCTS 36 1914.01 DUCT PANEL 12 1304.810 31.3/16 •MININUN DISTANCES:IF UNIT IS PLACED LESS THAN 12 1304.81 FROM WALL 1792.2] 2-5/8 1613/16 SYSIEM,IHEN SYSTEM PERFORMANCE MAYBE COMPROMISED. J [66.7] 11189.0] DIMENSIONS IN II ARE IN MILLIMETERS IIIIIII1 IIIIIIIIIIIIIIIIII4 JIIIIIIIIIIII 9 1-3/4 144.5]DIA. K.O. POMER ENTRY SUPPLYDUCT • RETURN IG illE 11403�21 OPENING DUCT • OPENING t. 1-1/1I'15/81181.2]_ 12-73/16 ,192.1] / : ,- - - - [315.4] rf 7-3/8 �-• - • T .Or_�.�O • �.... Q. 11 66.71 GG • ' ' 'DRAIN OUTLET 12-13/16 LONER I 3/16 1 3/4' 119.01N.P.T. 1325.11 COMPRESSOR PANEL 3-7/16 f1.81 3.1/16-.i %7/8' 122.01 DEEP PANEL ELECTRICAL [87.31 [87.3] ACCESS PANEL 7/8 122.2]DIA. HOLE 32-5/8 18-3/16 4-13/16 CONTROL ENTRY 9-1/8 215/8 9-7/8 [826.7] [1221.01 [122.21 1250.8] [549.31 1250.81 LEFT SIDE VIEW FRONT VIEW RIGHT SIDE VIEW REAR VIEW 50VT500410 n Sn 0 in co 01 50VT-C ROOF CURB ACCESSORY DIMENSIONS B Deehed linea show crow eopPorl \, location for large basepan unite. HVAC unit HVAC unit C'' Z base rails basepan 0 Sealing - 411111% �\ 1 Gasket �/Roofcurb ?1' ., Anchor screws:i 17 ` Wood nailer' A F Flashing field supplied Rion b* / . Insulation Roofing material (field supplied) `' field supplied r'1 E Cant strip field supplied ti \\\moi , / U \ A09413 SMALL/COMMON CURB / c *Provided with roofcurb tr) A09090 ROOF CURB DETAIL G \�C \ # 49,4.. , w SMALL \ BASE \ UNIT 4 /1 44 ill 4, / ,,P/: -F A , LARGE •`a' a BASE UNIT D UNIT PLACEMENT ON / .. COMMON CURB A09094 LARGE CURB A09415 SMALL OR LARGE BASE UNIT A09414 UNIT CATALOG A B(small/common B(large base) C D E F G H SIZE NUMBER (mm) IN.(mm)* IN.(mm)* (mm) IN.(mm) IN.(mm) (mm) IN.(mm) IN.(mm) Small Lara 9r CPRFCURB011 A00 14(356) 10(254) 14(356) 16(406) 47.8(1214) 32.4(822) 2.7(69) 30.6(778) 46.1 (1170) i Large CPRFCURB013A00 14(356) 14(356) 43.9(1116) 42.2(1072) *Part Number CPRCURB011 A00 can be used on both small and large basepan units.The cross supports must be located based on whether the unit is a small basepan or a large basepan. NOTES: 1.Roof curb must be set up for unit being installed. 2.Seal strip must be applied,as required,to unit being installed. 3.Roof curb is made of 16—gauge steel. It 4.Attach ductwork to curb(flanges of duct rest on curb). 5.Insulated panels:1—in.(25 mm) thick fiberglass 1 lb.density. 9 ELECTRICAL DATA VOLTAGE NOMINAL NOMINALRANGE COMPRESSOR OFM IFM ELECTRIC POWER SUPPLY MODEL V-PH-HZ HEAT MIN MAX RLA LRA FLA FLA kW FLA MCA MOCP -/- -/- 21.3 30 24 208/230-1-60 197 253 13.5 58.3 0.6 3.8 3.8/5 18.1/20.8 43.9/47.3 45/50 5.4/7.2 25.9/30 53.7/58.8 60/60 7.5/10 36.1/41.7 66.4/73.4 70/80 -/- -/- 22.1 35 3.8/5 18.1/20.8 44.8/48.1 45/50 30 208/230-1-60 197 253 14.1 73 0.7 3.8 5.4/7.2 25.9/30 54.5/59.6 60/60 7.5/10 36.1/41.7 67.3/74.3 70/80 11.3/15 54.2/62.5 89.9/100.3 90/110 -/- -/- 25.8 40 3.8/5 18.1/20.8 48.4/51.7 50/60 208/230-1-60 197 253 16.7 79 1 3.8 5.4/7.2 25.9/30 58.1/63.2 60/70 7.5/10 36.1/41.7 70.9/77.9 80/80 U 11.3/15 54.2/62.5 93.5/103.9 100/110 1 36 -/- -/- 18.2 25 > 208/230-3-60 197 253 10.4 73 1 4.1 3.8/5 10.4/12 31.2/33.2 35/35 p 7.5/10 20.8/24.1 44.2/48.3 45/50 in 11.3/15 31.2/36.1 57.2/63.3 60/70 -/- -/- 11 15 460-3-60 414 506 5.8 38 0.5 3.2 10 12/12 26/26 30/30 15 18/18 33.5/33.5 35/35 -/- -/- 29 45 3.8/5 18.1/20.8 51.6/55 60/60 208/230-1-60 197 253 19.3 112 1 3.8 5.4/7.2 25.9/30 61.4/66.5 70/70 7.5/10 36.1/41.7 74.1/81.1 80/90 11.3/15 54.2/62.5 96.7/107.1 100/110 15/20 72.2/83.3 119.2/133.1 125/150 -/- -/- 22.1 35 42 3.8/5 10.4/12 35/37 35/40 208/230-3-60 197 253 13.5 88 1 4.1 7.5/10 20.8/24.1 48/52.2 50/60 11.3/15 31.2/36.1 61/67.2 70/70 15/20 41.4/47.9 73.8/81.9 80/90 -/- -/- 11.2 15 460-3-60 414 506 6 44 0.5 3.2 10 12/12 26.2/26.2 30/30 15 18/18 33.7/33.7 35/35 20 24.1/24.1 41.4/41.4 45/45 -/- -/- 33.2 50 3.8/5 18.1/20.8 55.8/59.2 60/60 208/230-1-60 197 253 19.6 130 1.1 7.6 5.4/7.2 25.9/30 65.5/70.7 70/80 7.5/10 36.1/41.7 78.3/85.3 80/90 11.3/15 54.2/62.5 100.9/111.3 110/125 15/20 72.2/83.3 123.4/137.3 125/150 -/- ---- 25.8 35 48 3.8/5 10.4/12 38.8/40.8 40/45 208/230-3-60 197 253 13.7 83.1 1 7.6 7.5/10 20.8/24.1 51.8/55.9 60/60 11.3/15 31.2/36.1 64.8/70.9 70/80 15/20 41.4/47.9 77.5/85.7 80/90 -/- -/- 12.3 15 460-3-60 414 506 6.2 41 0.5 4 10 12/12 27.3/27.3 30/30 15 18/18 34.8/34.8 35/35 20 24.1/24.1 42.4/42.4 45/45 -/- -/- 39.5 60 3.8/5 18.1/20.8 62.1/65.5 70/70 208/230-1-60 197 253 24.4 144.2 1.3 7.7 5.4/7.2 25.9/30 71.9/77 80/80 7.5/10 36.1/41.7 84.6/91.6 90/100 11.3/15 54.2/62.5 107.3/117.6 110/125 15/20 72.2/83.3 129.8/143.6 150/150 -/- -/- 28.7 40 60 3.8/5 10.4/12 41.7/43.7 45/45 208/230-3-60 197 253 16 110 1 7.6 7.5/10 20.8/24.1 54.7/58.8 60/60 11.3/15 31.2/36.1 67.7/73.8 70/80 15/20 41.4/47.9 80.4/88.5 90/90 j -/- -/- 14.3 20 460-3-60 414 506 7.8 52 0.5 4 10 12/12 29.3/29.3 30/30 _ 15 18/18 36.8/36.8 40/40 20 24.1/24.1 44.4/44.4 45/45 See Legen•and Notes. 28 S U B M I T T A L , MicroMeti Part Number: • 0A2-SDSML-CD FORM NO.7945-1 D I 10/20/2014 Submitted To: ,� Company: a. � Job Name: ' 1.29.925," Notes: � ° A Motorized Air Hoods 4jj1I !i • ....,, ,,,,. I .., ., .... .. NOTES15 925" 8.5 O\ • CFM is Dependent Upon Duct Static Pressure,Air Velocity, �� Duct Size and Damper Position. • When Used In A Horizontal Application,Hood Must Be [44114 11 I Secured Over A Field Cut Opening In The Side of A Field Supplied Return Air Duct. • • Please Add The Suffix"FI:'To Part Number For Water Entrainment Filters,Call Factory For Details&Cost. • For Best Results,Wire Motor To 24 Volt AC Indoor Fan. 24-114" � FILTER RACK SIZE Supply air 1"Filters (2)12"x 20"x 1" FEATURES cover panel. • 2"Filters (1)10"x 20"x 2" Shipped on gilliii � ' . (1)12"x 20"x 2" HVAC unit • Hood Is Completely Factory Assembled And Painted. "1"Filters shipped with package IIIIIIIIIIIIII ��I�II • Includes Sealing Gasket and Installation Hardware 41� 1 Illlr :'��.0 • Outside Isolation Provided By Means of Screen Or Mesh / On the newer %T.I ;', is units,this • Filter Rack Included,Designed For Easy Installation. ` a / / is( 2)separate panels • Two Positions Only—Open or Closed. Coil • Can Be Used In Vertical,or Horizontal Applications. `� / 0/A I 0 Hood Panel,Shipped Hood e panel is shipped with the with Package Sid HVAC unit. Remove to install H0 -ID filter rack and replace filters. TOP VIEW THIS DOCUMENT IS THE PROPERTY OF MICROMETL CORPORATION AND IS DELIVERED UPON THE EXPRESS CONDITION THAT THE CONTENTS WILL NOT BE DISCLOSED OR USED WITHOUT MIROMETL'S WRITTEN CONSENT MicroMetl Corporation... Indianapolis Indiana — 1-800-662-4822, Sparks Nevada — 1-800-884-4662, Longview Texas— 1-903-248-4800 //�� SUBMITTAL DATA: SLZ-KA15NA & SUZ-KA15NA I��YF-S ER I E S 15,000 BTU/H CEILING-CASSETTE HEAT-PUMP SYSTEMS �MITSUBISHI ELECTRIC Job Name: System Reference: Date: ~ Electrical Requirements Power Supply 208/230V,1-Phase,60 Hz Recommended Fuse/Breaker Size 15 A ( , Voltage I dor OtdSAC 208/ .140 :---. .'''''''N. IndoorIno --Outdooruoor S2-S31-S2 DC±24V230V � OPERATING CONDITIONS t ' Indo • or Intake Air Outdoor Intake AirTemp. Temp. Indoor Unit SLZ-KA15NA Outdoor Unit:SUZ-KA15NA Maximum 90°F(32°C)DB 115°F(46°C)DB Cooling4 73°F(23°C)WB Minimum 67°F(19°C)DB 14°F(-10°C)DB 57°F(14°C)WB GENERAL FEATURES Maximum 80°F(27°C)DB 75°F(24°C)DB • Four-way 2'x2'ceiling-cassette indoor unit for ceiling recessed Heating 67°F(19°C)WB 65°F(18°C)WB applications Minimum 70°F(21°C)DB -4°F(-20°C)DBS • Built-in drain mechanism for condensate removal;lifts to 19-11/16" 60°F(16°C)WB -5°F(-21°C)WB • Wide air-flow pattern for better air distribution • Design features ventilation air intake knockout °Applications should be restricted to comfort cooling only;equipment cooling applications are not • Long-life air filter included with indoor unit recommended for low ambient temperature conditions. g 'System cuts out at-9°F(-27°C)to avoid thermistor error and automatically restarts at-4°F(-20°C). • Indoor unit powered from outdoor unit using A-Control • Choice of fan speed:Low,Medium,High • Automatic restart following a power outage • Limited warranty:five years parts and seven years compressors Indoor Unit MCA 1 A Fan Motor Output 20 W ACCESSORIESFan Motor(ECM) 0.28 F.L.A. Indoor Unit o Condensate PumpBlueDiamond X87-711/721;115/230 Airflow(Lo Med-Hi) 280-320-390 Dry CFM o Condensate Pum (Saermann SI30-115/230;115/230 o -290-e H0oneycomb Wet CFM � Air Filter Polypropylene Honeycomb o Grille(SLP-15AAUW;required-shipped with unit) Sound Pressure Level(Lo-Med-Hi) 31 -35-40 dB(A) Outdoor Unit DIMENSIONS UNIT INCHES/MM GRILLE ❑ Three-pole Disconnect Switch(TAZ-MS303) INCHES/MM o Air Outlet Guide(MAC-889SG) W 22-7/16/570 25-5/8/650 ❑ Mounting Base(DSD-400P) D 22-7/16/570 25-5/8/650 o Mounting Pad(ULTRILITE1) H 9-1/4/235 13/16/20 o Wall Mounting Bracket(QSWB2000M-1) Weight(Unit/Grille) Controller Options kgs. 16.5/3 o Wireless Controller(MHK1) External Finish(Unit/Grille) Galvanized-steel Sheets/ o Wired Remote Controller(PAR-32MAA-J) Munsell 6.4Y 8.9/0.4 o Wireless Interface for kumo cloudTM(PAC-WHSO1 WF-E) Field Drainpipe Size O.D. 1-1/4"/32 mm • Thermostat Interface(PAC-US444CN-1) o Hand-held Wireless Remote Controller (PAR-FL32MA;req.PAR-FA32MA-E) Outdoor Unit o Wireless Signal Receiver Module PAR-FA32MA Compressor DC Inverter-driven Twin Rotary (for PAR-FL32MA-E) MCA 12 A MOCP 15 A Fan SPECIFICATIONS Sou dotor Pressure Level 0 50 F.L.A. Cooling' Cooling 49 dB(A) Rated Capacity 15,000 Btu/h Heating 51 dB(A) Minimum to Maximum Capacity Range 3,800-17,700 Btu/h SEER 16.0 Btu/h/W DIMENSIONS INCHES/MM EER 10.2 Btu/h/W W 31-1/2/800 Total Input 1,460 W D 11-1/4/285 Heating at 47°F2 H 21-5/8/550 Rated Capacity 18,000 Btu/h Minimum to Maximum Capacity Range 3 100-22,200 Btu/h Weight 80 lbs./36 kg HSPF 9 6 Btu/h/W External Finish Munsell No.3Y 7.8/1.1 COP 2 71 Refrigerant Type R410A Total Input 1,950 W Refrigerant Pipe Size O.D. Heating at 17°F3 Gas Side 1/2"/12.7 mm Rated Capacity 10,200 Btu/h Liquid Side 1/4"/6.35 mm Rated Total Input 1,310 W Max.Refrigerant Pipe Length 65'/19.8 m COP 1 99 Max.Refrigerant Pipe Height Difference 40'/12.2 m 4 Maximum Capacity" 12,000 Btu/h Connection Method Flared Maximum Total Input 1 970 W 'Cooling I Indoor:80°F(27°C)DB/67°F(19°C)WB' 'Cooling I Outdoor:95°F(35°C)DB/75°F(24°C)WIT 2 Heating at 47°F I Indoor:70°F(21°C)DB/60°F(16°C)WE 2 Heating at 47°F I Outdoor:47°F(8°C)DB/43°F(6°C)WIT 3 Heating at 17°F I Indoor:70°F(21°C)DB/60°F(16°C)1NE 3 Heating at 17°F I Outdoor:17°F(-8°C)DB/15°F(-9°C)WB' •Rating Conditions perAHRI Standard "Maximum Capacity is at full speed and performance for INVERTER-driven System. Specifications are subject to change without notice. 0 2016 Mitsubishi Electric US,Inc. IIIIk. A • DIMENSIONS: SLZ-KA15NA Unit: inch (mm) _ I Co. Fresh air I Detail drawing of fresh air intake intake y 03-15/16(0100) 1 25 \ / QS2-7/8073.4) e \ 20-7/8t530) / 3-01/8(02.8) c t Cut out hole E Burring hole TL \$uspensio1l bolt pitch/ ■- T.) c'') 0 o« `\ � / I M N _ �/ I M o _-_-_-_-_-_- __-_--____ ._ (zO 4 N N /) II • coR 50 r C /' 1 s\ M r O co \` 11,%; N. u, N N •22-7/16570)\• v ��— o • N 4111 / I \ rn N 9 - Ceiling surface N I I 2 LOI j 7-27/32(199) N 13-27/32(352) r 13-3/16(335) N N 19/32-1-15/32(15-37) 22-11/16-24-13/32(576-620) Ceiling hole 19/32-1-15/32(15-37) Drain pipe Wiring entry co VP-25 connection Refrigerant 21/32(17) 7-15/16 202 9-1/16 230 (O.D.01-1/4(032))) co:,' pipe(gas) ' Suspension bof M10 or W3/8 `1 l! IlliM. !ti II r) Refr erant � c5 pipe iquid) 111.?5, ill =Rik VI r=:': I .. rr c171) . 1E1 III I/ ., �� _ I L.4 iif4 ��J TM COa _ • - la c, m ° Terminal block Grille N N co 0 Ceiling surface v � V. °o) m0 1n CD y'O C') N N at + N SO m Models Refrigerent pipe Refrigerent pipe 25-19/32(650) (liquid) (gas) co 11-27/32(301)co 1/4 inch 3/8 inch co Air outlet hole Brand label SLZ-KA09NA (�6.35mm) (95 9.52mm) ��/Grille flared connection flared connection Lo y Drain hole 1/4 inch 3/8 inch co • m • SLZ-KAl2NA (56 6.35mm) (¢9.52mm) N Al, • Auto vane flared connection flared connection - 1/4 inch 1/2 inch p d SLZ-KA15NA (0 6.35mm) 0 12.7mm) o IC co t flared connection flared connection N N-C _. N 0) 52 c1 d ___ _._ - (2 N N O N 8 N ` 4 Q 4 . , IJY1 -'?1 r 1I., 1 Air intake grille -Vane motor 14-27/32(377) Air intake hole 1-3/8(35) . 2-5/32(55) Specifications are subject to change without notice. ®2016 Mitsubishi Electric US,Inc. DIMENSIONS: SUZ-KA15NA 15-3/4 Drain hole 01-5/8 Unit: inch cl 0.Air in _ ,-v r .0 A- A r� 7 M — Air in b 7 -a?-41 z t cn • N 1311141614114141614111 i y V V A 1-9/16 bAir out 2-3/8 x 13/16 Oval hole 7/8> 29/32 . 11-1/4 ,17/32 handle /� IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII of IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII - ---- 111111111111111,1111111111111111111111 .... N M illlllllllllllllllllllllllllllllllllllFt: IIIIIIIIilllllllllllllllllllllllllllll _AL 00Ipi�1 Liquid pipe :1/4(flared) IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII J' Gas pipe :3/8(flared)(KA09/12) V v v — - _i w _k 1/2(flared)(KA15) CV11-29/32 6-23/32 <5-15/15 '19-11/16 < 31-1/2 > .2-23/32 REQUIRED SPACE Basically open 4 inch or more without any obstruction in front and on both sides of the unit. of mote 4 gin' 4ihor ,77oc, IN IIp/fi 1 �400e h oi- 8.0. r� , e Open two sides of left, right,or rear side. MITSUBISHI /_ ELECTRIC 4 COOLING & HEATING 1340 Satellite Boulevard.Suwanee,GA 30024 Toll Free:800-433-4822 www.mehvac.com R/CERTIFIED, cE �ry=m�P - us FORM#SLZ-KAI5NA-SUZ-KA15NA-201604 -.....—_ m.-- Intertek Specifications are subject to change without notice. 0 2016 Mitsubishi Electric US,Inc. PA- SLAMS SUBMITTAL DATA: SLZ-KAl2NA & SUZ-KAl2NA MITSUBISHI 12,000 BTU/H CEILING-CASSETTE HEAT-PUMP SYSTEMS ELECTRIC Job Name: System Reference: Date: ENERGY STAR® Yes ENERGY STAR products are third-party certified by an EPA-recognized Certification Body. - _ Electrical Requirements Power Supply 208/230V, 1-Phase,60 Hz Recommended Fuse/Breaker Size 15 A ,A A, Voltage ,.-°� ,d '"I Indoor-Outdoor S1-S2 AC 208/230V -' Indoor-Outdoor S2-S3 DC±24V • Indoor Unit:SLZ-KAl2NA Outdoor Unit:SUZ-KAl2NA OPERATING CONDITIONS Indoor Intake Air Outdoor Intake Air Temp. Temp. Maximum 90°F(32°C)DB 115°F(46°C)DB GENERAL FEATURES Cooling* 73°F(23°C)WB • Four-way 2'x2'ceiling-cassette indoor unit for ceiling recessed67°67°F(19°C)DB 14°F(-10°C)DB applications 57°F(14°C)WB • Built-in drain mechanism for condensate removal;lifts to 19-11/16" Maximum 80°F(27°C)DB 75°F(24°C)DB • Wide air-flow pattern for better air distribution 67°F(19°C)WB 65°F(18°C)WB • Design features ventilation air intake knockout Heating 70°F(21°C)DB -4°F(-20°C)DB • Long-life air filter included with indoor unit Minimum 60°F(16°C)WB 5°F(-21°C)WBS • Indoor unit powered from outdoor unit using A-Control • Choice of fan speed:Low,Medium,High °Applications should be restricted to comfort cooling only;equipment cooling applications are not • Automatic restart following a power outage recommended for low ambient temperature conditions. • Limited warranty:five years parts and seven years compressors 5 System cuts out at-9°F(-27°C)to avoid thermistor error and automatically restarts at-4°F(-20°C). ACCESSORIES Indoor Unit Indoor Unit ❑ Condensate Pump(BlueDiamond X87-711/721;115/230V) MCA 1 A ❑ Condensate Pump(Sauermann SI30-115/230;115/230'd) Fan Motor Output 20 W ❑ Grille(SLP-15AAUW;required-shipped with unit) Fan Motor(ECM) 0 28 F.L.A. Airflow(Lo-Med-Hi) 280-320-390 Dry CFM 1 250-290-350 Wet CFM Outdoor Unit Air Filter Polypropylene Honeycomb o Three-pole Disconnect Switch(TAZ-MS303) Sound Pressure Level(Lo-Med-Hi) 30-34-39 dB(A) o Air Outlet Guide(MAC-889SG) o Mounting Base(DSD-400P) , GRILLE ❑ Mounting Pad(ULTRILITEI) DIMENSIONS UNIT INCHES/MM INCHES/MM o Wall Mounting Bracket(QSWB2000M-1) W 22-7/16/570 25-5/8/650 _ Controller Options D 22-7/16/570 25-5/8/650 o Wireless Controller(MHK1) H 9-1/4/235 13/16/20 o Wired Remote Controller(PAR-32MAA-J) o Wireless Interface for kumo cloud TM'(PAC-WHSO1 WF-E) Weiigsht(Unit/Grille) 36/7 o Thermostat Interface(PAC-US444CN-1) o Hand-held Wireless Remote Controller kg 16.5/3 (PAR-FL32MA;req.PAR-FA32MA-E) External Finish(Unit/Grille) Galvanized-steel Sheets/ 0.4 o Wireless Signal Receiver Module PAR-FA32MA Field Drainpipe Size O.D. Munsel1-1/4"8.9 2/mm (for PAR-FL32MA-E) SPECIFICATIONS Outdoor Unit Cooling' Compressor DC Inverter-driven Rated Capacity 11,100 Btu/h MCA 12A Minimum to Maximum Capacity Range 3 400-13,300 Btu/h MOCP 15 A SEER 15.4 Btu/h/W Fan Motor(ECM) 0 50 F.L.A. EER 12.0 Btu/h/W Sound Pressure Level Total Input 920 W Cooling 49 dB(A) Heating at 47°F2 Heating 51 dB(A) Rated Capacity 13,600 Btu/h Minimum to Maximum Capacity Range 3 100-17,100 Btu/h HSPF 9 6 Btu/h/W DIMENSIONS INCHES/MM COP 3 38 W 31-1/2/800 Total Input 1,180 W D 11-1/4/285 Heating at 17°F3 H 21-5/8/550 Rated Capacity 8 300 Btu/h Rated Total Input 930 W COP 2 62 Weight 77 lbs./35 kg Maximum Capacity" 8 300 Btu/h External Finish Munsell No.3Y 7.8/1.1 4 Maximum Total Input 1 310 W Refrigerant Type R41 OA 'Cooling Indoor:80°F(27°C)DB/67°F(19°C)WB' RefriGas Side PPipe Size O.D. 3/8"/9.52 mm 'Cooling I Outdoor:95°F(35°C)DB/75°F(24°C)WB' Liquid Side 1/4"/6.35 mm 2 Heating at 47°F I Indoor:70°F(21°C)DB/60°F(16°C)WB' Max.Refrigerant Pipe Length 65'/19 m 2 Heating at 47°F I Outdoor:47°F(8°C)DB/43°F(6°C)WB' Max.Refrigerant Pipe Height Difference 40'/12 m 3 Heating at 17°F I Indoor:70°F(21°C)DB/60°F(16°C)WU Connection Method Flared 3 Heating at 17°F I Outdoor:17°F(-8°C)DB/15°F(-9°C)WB' •Rating Conditions per AHRI Standard "Maximum Capacity is at full speed and performance for INVERTER-driven System. Specifications are subject to change without notice. 0 2016 Mitsubishi Electric US,Inc. t , DIMENSIONS: SLZ-KAI2NA Unit: inch(mm) i , P. Fresh air I Detail drawing of fresh air intake ,s, intake s IL :+)' I frw• i c63-15/16(¢100) 1 25 02-7/8(pl73.4) ` .\ 20-7/80530) /,. 3- 1/8(02.8) Cut out hole cBurring hole .2 \Suspension bolt pitch/ ED ,�nc ` VJr oN \ / I \m \ \ Z d iI ` M N MM cy / \ N .22-7/16570) cl(/) N ' :72- ildAi., / /' I 2 fNCO r. �e�` \ N m N Ceiling surface N N N 7-27/32(199) 7-1. E 13-27/32(352) N N 13-3/16(335) 19/32-1-15/32(15-37) 22-11/16-24-13/32(576-620) Ceiling hole 19/32-1-15/32(15-37) Drain pipe Wring entry 21/32(17) 7-15/16 202 9-1/16 230 VP-25 connection Refrigerant (0.0.01-1/4(032)) N pipe 1gas) I pension bolt M10 or W3I8 !ii iliiillh=riLjJ m�5 '-.11=111 VI a OD m co• ° Terminal block Grille N co Ceiling surface N N N ga, M O' CmN N 5.- + N 59 O • Models Refrigerent pipe Refrigerent pipe 25-19/32(650) (liquid) (gas) m 11-27/32(301) 1/4 inch 3/8 inch Air outlet hole Brand label SLZ-KAO9NA (0 6.35mm) (0 9.52mm) r 1 . Grille flared connection flared connection y@Co- 4 .1' _Drain hole 1/4 inch 3/8 inch N —_ SLZ-KAl2NA (0 6.35mm) (0 9.52mm) N — Auto vane flared connection flared connection 1/4 inch 1/2 inch g ^° / a SLZ-KA15NA (95 6.35mm) ($12.7mm) ro ll L N s t flared connection flared connection 12 N YJ N C A L- N •-.1 Q - T „ ll i'',Silk intake grille -Vane motor j 14-27/32(377) Air intake hole 1-3/8(35) 2-5/32(55) Specifications are subject to change without notice. 0 2016 Mitsubishi Electric US,Inc. DIMENSIONS: SUZ-KAl2NA 15-3/4 Drain hole 01-5/8 Unit: inch M ,Air in '_v _eft Frr=i i- c A v C7 cc N • Air in c> co z "a? • c) ' inumpuulaumuumuumuuur i '-v v A 1-9/16 b Air out 2-3/8 x 13/16 Oval hole 7/8>4 29/32 . 11-1/4 17/32 handle 7 I 111111111111111111111111111111111111111111 ^� IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII oo IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII -1IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII N c%1 IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII ^,� Liquid pipe :1/4(flared) IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII �� �„ -7 i Gas pipe :3/8(flared)(KA09/12) r r` ,_ 1/2(flared)(KA15) cy 11-29/326-23/32 co <5-15/1 , 19-11/16 31-1/2 2-23/32 REQUIRED SPACE Basically open 4 inch or more without any obstruction in front and on both sides of the unit. 01 mple A gin' 1640/ .07 • `�!�— mole II ,j in or 8`n,01 r' °re -.........741....7.--- Open it Open two sides of left, right,or rear side. MITSUBISHI 4 MIL ELECTRIC COOLING & HEATING 1340 Satellite Boulevard.Suwanee,GA 30024 - Toll Free:800-433-4822 www.mehvac.com ti:di CERTIFIED. c i- us FORM#SLZ-KAl2NA-SUZ-KAl2NA-201604 -.,—., .....,..,..",-- Intertek Specifications are subject to change without notice. ©2016 Mitsubishi Electric US,Inc. -'" PEAD-A30AA5 & PUZ-A3ONHA6 (-BS) MITSUBISHIP-SERIES30,000 BTU/H HORIZONTAL-DUCTED HEAT-PUMP SYSTEMMWE Job Name: System Reference: Date: ` " Electrical Power 208/230V, 1-Phase,60 Hz Requirements C Minimum Circuit Am (MCA) Y t Indoor Unit:PEAD-A30AA5Indoor/Outdoor A 2.73/25 Outdoor Unit PUZ-A3ONHA6(-BS) Indoor Unit UNIT OPTION: Blower Motor(ECM) F.L.A. 2.18 o Standard Model PUZ-A3ONHA6 Blower Motor Output w 121 o Seacoast(BS)Model PUZ-A3ONHA6-BS SHF/Moisture Removal 0.68/8.6 pt./h ACCESSORIES: External Static Pressure In.WG 0.14-0.20-0.28-0.40-0.60 Indoor Unit Drain Lift Mechanism H:In. 27 9/16 o Condensate Pump(BlueDiamond X87-711/721;115/230V) (Included) o Condensate Pump(Sauermann SI30-115/230;115/230V) o Filter Box&MERV 13 Filter(FBM2-3) ❑ Disconnect Switch(TAZ-MS303) Outdoor Unit Outdoor Unit Compressor DC INVERTER-driven Twin Rotary ❑ Wind Baffle(WB-PA2an Motor(ECM) F.L.A. 0.75 *Allows operation to 0°F(-18°Cr.) o Air Outlet Guide(PAC-SG59SG-E) MOCP A 40 o Mounting Base(QSMS1201) ❑ Wall Bracket(QSWB2000M-1) Airflow Rate(Low-Mid-Hi) Controls Indoor DRY 618-742-883 ❑ Wireless Controller(MHK1) (Cooling) ❑ Advanced Wired Controller(PAR-31 MAA) WET CFM 565-671-812 ❑ Simple Wired Controller(PAC-YT53CRAU) ❑ M-NET Adapter(PAC-SF83MA-E) Outdoor DRY 1,940 ❑ Temperature Sensor(PAC-SE41TS) Sound Pressure Level SPECIFICATIONS: Indoor(Low-Mid-Hi) 30-34-39 - Rated Conditions(Capacity/Input)* Cooling dB(A) 48 Outdoor _ Cooling Btu/h/w 30,000/3,850 Heating 50 Heating at 47°F Btu/h/W 32,000/2,990 External Dimensions Heating at 17°F Btu/h/W 23,000/2,750 9-7/8 x 43-5/16 x 28-7/8 Indoor(H x W x D) 'Rating Conditions per AHRI Standard: (250 x 1,100x732) Cooling I Indoor:80°F(27°C)DB/67°F(19°C)WB;Outdoor:95°F(35°C)DB/75°F(24°C)WB In.(mm) Heating at 47°F I Indoor:70°F(21°C)DB/60°F(16°C)WB;Outdoor:47°F(8°C)DB/43°F(6°C)WB 37-1/8 x 37-3/8 x 13+ 1-3/16 Heating at 17°F I Indoor:70°F(21°C)DB/60°F(16°C)WB;Outdoor:17°F(-8°C)DB/15°F(-9°C)WB Outdoor(H x W x D) (943 x 950 x 330+30) Capacity Range External Finish Cooling Btu/h 12,000-30,000 Indoor Galvanized-steel Sheet Heating at 47°F Btu/h 12,000-34,000 Outdoor Munsell No. 3Y 7.8/1.1 Operating Range Cooling 0°F**to 115°F(-18°C to 46°C) DB Net Weight Indoor 73(33) Heating 12°F to 70°F(-11°C to 21°C)DB Lbs.(kg) Outdoor 165(75) '*The minimum temperature will be 23°F(-5°C)DB if optional wind baffle accessory is not instated. Refrigerant R410A; 6lbs., 10oz. AHRI Efficiency Ratings -ER 7.7 Refrigerant Piping(Flared) SEER 15.5 Liquid(High Pressure) 3/8(9.52) In.(mm) HSPF 9.4 Gas(Low Pressure) 5/8(15.88) COP at 47°F 3.13 Maximim Total Ft.(m) 165(50) COP at 17°F 2.45 Refrigerant Pipe Length Maximum Vertical Ft.(m) 100(30) Separation Specifications are subject to change without notice. ©2015 Mitsubishi Electric US,Inc. s DIMENSIONS: PEAD-A30AA5 & PUZ-A3ONHA6 (-BS) Ventilation air intake 0100(3-15/16) ▪ PEAD-A30AA5 Drain pipe(O.D.032(1-1/4)) - 378(12-7/161 - 153(6-1/16 knock out hole Note 4 Unit mm(inch) (Emergency draining) 20 i , , 3-02.9(1/8)mounting hole - �n 01• 25 . S4-16/16) '0 y, m m �� - . ',n Suspension bolt hole (13-5/16) 4-i4x3019/16X1-3/161 Slot 18(3/4) 210 y 1 5/8 r H 2xE-02.9(1/8) AR.. TI I � 1 1. I. + I il ° Air filter AirC. Air �Ir .; � outlet inlet .- m ft•: 4 r..111 • 10(7/16) I u "f ;I mN1 m (Suspension bolt pitch) F2- & a I 57(2-1/4/ - 643125-3/e) - ModelA B - C 0 E - F G H J K L M N OGas pipe®Liquid pipe PEAD-A24,30AA4 1100 1154 1200 1060 11 1000 1058 1200 49 330 4 990 10 (43-5/16)(45-7/16) (47-1/4) (41-314) (39-3/8) (41.111161(47-1/4)(1-15/16) (13) (391 (715.88 09.52 1400 1454 1500 1360 14 1300 1358 1500 54 320 5 1280 12 (5/8 ) (3/8) PEAD-A36,42AA4 (55-1/8) (57-1/4)(59.1/16)(53-9/16) (51-3/16) (53.1/2) (59-1/16)(2-3/16) (12-5/8) (50.7/16) NOTE 1.Use M10 screw for the Suspension bolt(field supply). l 2.Keep the service space for the maintenance at the bottom. 3.This chart indicates for PEAD-A24.3036-42AA4 models,which have 2 fans. 4.In case of the inlet duct is used,remove the air filter(supplied with the unit),then install a filter(field supplied)at suction side. PUZ-A3ONHA6(-BS) Unit:mm(inch) ti s 8. 0'1 PA 943<37-1/8> - __ 81<3-3116> 219<8-5/8> 473<18-5/8> m 23<29/32> 30<1-3/16> 330 413> �1:, _ _ _ 1. Q w 2 S0- 4111Itel lil 1.4 4, __ ill l±. iii; 1<2-13116' D O `� p mimial •1 443<17-7/16> m 8 —_v g n g g T m 8 ii 0 N 45<1-25/32> 'x •1 447<17-19/32> g c 4- " o—53<2-3/32> 111 56<2-7/32> g 3 g _ - 870<26-3/8> moa Q `m -(---g: _ _ 8 I "28<13/32>I 370<14-9/16> 19<3l4> v_ v� 417<16-13/32> ' Ea MITSUBISHI �,( ,- M% ELECTRIC * , COOLING & HEATING I' - • NOTES: SEACOAST PROTECTION • External Outer Panel:Phosphate coating+Acrylic-Enamel coating 1340 Satellite Boulevard.Suwanee,GA 30024 • Fan Motor Support:Epoxy resin coating(at edge face) - • Separator Assembly;Valve Bed:Epoxy resin coating(at edge face) Toll Free:800-433-4822 www.mehvac.com • Screws(used outer side):Zinc nickel coating 5pm+ Polyvinylidene chloride coating "Blue Fin"treatment is an anti-corrosion treatment that Is applied to the condenser coil to protect it against airborne contaminants.. .S•..�1 CERTIFIED_ SUS US orw s0m•mnwzau . ," Intertek FORM#PEAD-A30AA5-PUZ-A3ONHA6(-BS)-201511 Specifications are subject to change without notice. 0 2015 Mitsubishi Electric US,Inc. '' PEAD-A36AA5 & PUZ-A36NHA6 (-BS) • MITSUBISHI '�'-SERIES 36,000 BTU/H HORIZONTAL-DUCTED HEAT-PUMP SYSTEM AM ELECTRIC Job Name: System Reference: Date: Electrical Power 208/230V, 1-Phase,60 Hz Requirements } • Minimum Circuit Ampacity(MCA) Indoor Unit PEAD-A36AA5 Indoor/Outdoor A 3.3/25 Outdoor Unit:PUZ-A36NHA6(-BS) Indoor Unit UNRC OPTION: Blower Motor(ECM) F.L.A. 2.64 o Standard Model PUZ-A36NHA6 Blower Motor Output W 244 ❑ Seacoast(BS)Model PUZ-A36NHA6-BSp SHF/Moisture Removal 0.75/7.9 pt./h ACCESSORIES: External Static Pressure In.WG 0.14-0.20-0.28-0.40-0.60 Indoor Unit ❑ Condensate Pump(BlueDiamond X87-711/721;115/230V) Drain Lift Mechanism H:In. 27-9/16 o Condensate Pump(Sauermann SI30-115/230;115/230\0 (Included) o Filter Box&MERV 13 Filter(FBM2-4) o Disconnect Switch(TAZ-MS303) Outdoor Unit Outdoor Unit Compressor DC INVERTER-driven Twin Rotary ❑ Wind Baffle(WB-PA2I* Fan Motor(ECM) F.L.A. 0.75 *Allows operation to o°F(-18° ). o Air Outlet Guide(PAC-SG59SG-E) MOCP A 40 o Mounting Base(QSMS1201) o Wall Bracket(QSVVB2000M-1) Airflow Rate(Low-Mid-Hi) Controls Indoor DRY 847-1,024-1,201 ❑ Wireless Controller(MHK1) (Cooling) o Advanced Wired Controller(PAR-31 MAA) WET CFM 777-953-1,130 ❑ Simple Wired Controller(PAC-YT53CRAU) ❑ M-N ET Adapter(PAC-SF83MA-E) Outdoor DRY 1,940 ❑ Temperature Sensor(PAC-SE41TS) Sound Pressure Level SPECIFICATIONS: Indoor(Low-Mid-Hi) 33-38-42 - Rated Conditions(Capacity/Input)* Cooling dB(A) 48 Outdoor _ Cooling Btu/11 35,000/4,850 Heating 50 Heating at 47°F Btulh 37,000/3,290 External Dimensions Heating at 17°F Btu/h 25,000/2,810 Indoor(H x W x D) 9-7/8 x 55-1/8 x 28-7/8 *Rating Conditions per AHRI Standard: (250 x 1,400 x 732) Cooling I Indoor:80°F(27°C)DB/67°F(19°C)WB;Outdoor:95°F(35°C)DB/75°F(24°C)WB In.(mm) Heating at 47°F I Indoor 70°F(21°C)DB/60°F(16°C)WB;Outdoor 47°F(8°C)DB/43°F(6°C)WB 37-1/8 x 37-3/8 x 13+ 1-3/16 Heating at 17°F I Indoor:70°F(21°C)DB/60°F(16°C)WB;Outdoor:17°F(-8°C)DB/15°F(-9°C)WB Outdoor(H x W x D) (943 x 950 x 330+30) Capacity Range Net Weight Cooling Btu/h 12,000-35,000 Indoor 91 (41) Heating at 47°F Btu/h 12,000-38,000 Lbs.(kg) Outdoor 165(75) Operating Range External Finish Cooling 0°F**to 115°F(-18°C to 46°C) DB Indoor Galvanized-steel Sheet Heating 12°F to 70°F(-11°C to 21°C)DB Outdoor Munsell No. 3Y 7.8/1.1 **The minimum temperature will be 23°F(-5°C)DB if optional wind baffle accessory is not installed. Refrigerant R410A;6lbs., 10oz. .AHRI Efficiency Ratings -:ER 7.2 Refrigerant Piping(Flared) SEER 15.0 Liquid(High Pressure) 3/8(9.52) In.(mm) HSPF 9.8 Gas(Low Pressure) 5/8(15.88) COP at 47°F 3.29 Maximim Total Ft.(m) 165(50) COP at 17°F 2.60 Refrigerant Pipe Length Maximum Vertical Ft.(m) 100(30) Separation Specifications are subject to change without notice. 0 2015 Mitsubishi Electric US,Inc. y • DIMENSIONS: PEAD-A36AA5 & PUZ-A36NHA6 (-BS) Ventilation air intake 0100(3-15/16) PEAD-A36AA5 Drain pipe(O.D.032(1-1/4)) • 378(12-7/161 153(6-1/16 knock out hole Note 4 Unit mm(inch) (Emergency draining) 25 ip _ 4,fi 3-02.9(1/8)mounting hole 022 4-15/16) e- 111 N g, - _ =- mith Suspension bolt hole (g_5/16) 4-14x3019/16X1-3/161 Slot 18(3/a) z10 S 1 s/6 of H • 2xE-02.9(118)1 49- a , r ry 4 f M + LL 1111:a • w + a J Air filter Alar + • Air < .`sa v c2 milli 68- S ••§ outlet inlet Irl ad -- N ii 10(7/16) ,3 C.- (Suspension bolt pitch) - a 57(2-1/4) 643(25-3/8) Model A BCDEF GHJ K LMN ()Gas pipe®Liquid pipe PEAD-A24,30AA4 1100 1154 1200 1060 111000 1058 1200 49 330 4 990 10 (43-5/16)(45.7/16) (47-1/4)-(41-3/4) (39-3/8) (41.11116)-(47-1/4)(1-15/16) (13) _ (39) 015.88 09.52 1400 1454 1500 1360 14 1300 1358 1500 54 320 5 1280 12 (5/8) (3/8) PEAD-A36,42AA4 (55-1/8) (57-1/4)(59-1/16)(53-9/16) (51-3/16) (53-1/2) (59-1/161(2-3/16) (12-5/8) (50-7/16) NOTE 1.Use M10 screw for the Suspension bolt(field supply). 2.Keep the service space for the maintenance at the bottom. 3.This chart indicates for PEAD-A24.30-36-42AA4 models,which have 2 fans. 4.In case of the inlet duct is used,remove the air filter(supplied with the unit),then install a filter(field supplied)at suction side. PUZ-A36NHA6(-BS) Unit:mm(inch) K P n 2 •943<37-1/8> - \ /I 81<t-3/16> 219<8-5/8> 473<18-5/8> m ��V ■_/iI _ 23<29/32> 30<1-3/16> 330 13> P� I-II � a 7111 I 1 r315,4 �. } __ === _ C 1. • mg. I') ii,•- g.. �_ 1 a •1 443<17-7/16> m i• ETi i `d,' g gg --*F,,. •1 447<17-19/32> - t°- 9 N 45<1-25/32> c$ 5.12-53<2-3/32> II 56<2-7/32> g 3 2; SA _ - 670<26-3/8> � :o S[. c m 28<1-3/32>' 370<14-9/16> 19<3/4> 5 m o Q: ;,1 A 417<1613/32> m � , 2 . MITSUBISHI t �( /111k ELECTRIC COOLING & HEATING - - - - NOTES: SEACOAST PROTECTION • External Outer Panel:Phosphate coating+Acrylic-Enamel coating 1340 Satellite Boulevard.Suwanee,GA 30024 • Fan Motor Support:Epoxy resin coating(at edge face) - • Separator Assembly;Valve Bed:Epoxy resin coating(at edge face) Toll Free:800-433-4822 www.mehvac.com • Screws(used outer side):Zinc nickel coating 5pm+ Polyvinylidene chloride coating T "Blue Fin"treatment is an anti-corrosion treatment that is applied to the c 1 us condenser coil to protect it against airborne contaminants.. LAW P U �nZ1 Nidi - ..,.. ..m..,-,_� Intertek FORM#PEAD-A36AA5-PUZ-A36NHA6(-BS)-201511 Specifications are subject to change without notice. ©2015 Mitsubishi Electric US,Inc. Honeywell Automatic Round Dam erp (ARD) PRODUCT DATA FEATURES • Adjustable damper position range stops. • - • Single-blade damper. zre • Shipped as power closed/spring return open damper. ( /, • Galvanized steel. • Can be field-converted to power open/spring return :311,4 closed damper. • Blade closes off tightly against gasket for minimal leakage. • Rated to operate up to 1 in.wc.(see specifications). • Male(crimped)and female(uncrimped)ends to APPLICATION connect to any rigid or flexible round duct. The ARD is a round damper with a 24 Vac,spring-return damper motor used to control circulating air in heating, cooling,and ventilating systems. The damper is shipped as a powered closed/spring return open damper.The damper can be field-converted to a power open/spring return closed damper when used as an independent zone or for fresh air intake for ventilation or combustion make-up air. Contents Application 1 Features 1 Specifications 2 Ordering Information 2 Installation 3 Wring 3 Checkout 4 1111111111111111111 • 68-0260-02 . AUTOMATIC ROUND DAMPER(ARD) SPECIFICATIONS IMPORTANT Nominal Motor Timing at 77°F(25°C)Ambient: The specifications given in this publication do not Energized at rated load: 30 seconds. include normal manufacturing tolerances. Therefore, De-energized(spring return):10 seconds. this unit may not exactly match the listed specifica- tions.Also, this product is tested and calibrated Motor Ambient Temperature Rating:40°to 140°F(5°to under closely controlled conditions, and some minor 60°C). differences in performance can be expected if those conditions are changed. Leakage: Less than 1%at 1/2 in.wc. Construction: Pressure Drop: Maximum at full open:0.0329 in.wc at 800 Frame: Galvanized steel spiral duct, crimped on downstream ft/min. side. Sizes:5 in., 6 in., 7 in., 8 in., 9 in., 10 in., 12 in., 14 in., 16 in., Maximum Static Pressure: 1 in.wc for all models except 0.3 18 in., and 20 in.diameters. in.we for ARD20. Gauges:ARD5-ARD12:24 Gauge frame, and 22 Gauge blade Motor Shaft Rotation Direction: Clockwise,when ener- ARD14-ARD20: 22 Gauge frame, and 20 Gauge blade. gized and viewed from the base or shaft end. Motor Electrical Rating:24 Vac,60 Hz,6VA. Motor Mounting Means: Direct connection to damper shaft. Motor Electrical Connection:4 in. leadwire. Motor Mounting Position: Multi-poise. Motor Nominal Angular Rotation:90°. Motor Dimensions: See Fig. 1. Motor Torque: Minimum 60 in.-oz.(423 milli-newton meters) output torque available when motor is energized and device is at the spring return initial start position. * Nominal Device Dimensions(see Fig. 1.). A B C D E F in. 3-1/2 3 2-3/8 1-1/2 * ** mm 89 76 60 38 * ** *Diameter is derived from the part number,i.e.ARD10 has a 10 in. diameter. **Length is equal to the diameter plus 2 in. (51 mm) j1=_ ' B Fig.1.Motor dimensions in in.(mm). ORDERING INFORMATION When purchasing replacement and modernization products from your TRADELINE®wholesaler or distributor, refer to the TRADELINE®Catalog or price sheets for complete ordering number. If you have additional questions, need further information,or would like to comment on our products or services, please write or phone: 1. Your local Honeywell Automation and Control Products Sales Office(check white pages of your phone directory). 2. Honeywell Customer Care 1885 Douglas Drive North Minneapolis, Minnesota 55422-4386 In Canada—Honeywell Limited/Honeywell Limitee,35 Dynamic Drive,Toronto,Ontario M1V 4Z9. International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, Germany,Japan, Mexico, Netherlands, Spain,Taiwan, United Kingdom, U.S.A. 68-0260-02 2 i u AUTOMATIC ROUND DAMPER(ARD) INSTALLATION Adjusting a Motor 1. When viewed on end,the lower lever is normally posi- tioned to the extreme left and the upper lever is to the Before Installing this Product... extreme right. See Fig.2.This position provides com- l. Read all instructions before installing this product. Fail- plete shutoff when the damper is closed. ure to follow the instructions can damage the product or 2. To prevent complete closure of the damper, loosen(do cause a hazardous condition. not remove)the wing nut on the bottom of the motor and 2. Check the ratings given in the instructions and on the move the upper lever to the left until the desired position product to make sure the product is suitable for your is reached.Tighten the wing nut. In the extreme left posi- application. tion,the damper should stay open approximately 40° 3. Installer must be a trained,experienced service techni- when powered shut. clan. 3. The lower lever is normally positioned to the left to allow 4. Install the product in an area that is easily accessible for the damper to fully open 90°when de-energized. See checkout and service. Fig. 2. 5. After completing installation,use these instructions to 4. To restrict the air flow in the open position,loosen(do not check out the product operation. remove)the wing nut and move the level to the right until the desired position is reached.Tighten the wing nut. In the extreme right position,the damper should open Installing the Round Damper approximately 50°with the power off. 1. Insert the crimped end of the ARD into the uncrimped end of the rigid round duct and secure with rigid sheet metal screws(not provided).When using flexible duct, slip the duct over the end of the ARD and secure it with duct straps(not provided). 2. When installing the damper in a horizontal application, make sure the motor actuator is located on the side or IP UPPER LEVER top of the damper. Do not locate the motor on the bottom of the damper.The damper can be mounted in a vertical duct. .I' WING NUT WIRING \ I LOWER LEVER M20155 • CAUTION Fig.2.Air flow adjustment. Personal Electrical Shock Hazard. = Can cause electrical shock or equipment damage. Wiring a Single ARD (Power Open)to a Disconnect power before beginning installation. Thermostat The damper motor has a 24 Vac,50/60 cycle,6 VA rating.The spring-return ARD damper requires 24 Vac to the two motor leads to power the damper.The damper then returns to its normal position. See Fig.3 and 4 wiring diagrams. NOTE: Multiple ARD can be wired in parallel. Wiring a Motor See Fig. 3 and 4 for motor wiring hookups. Changing a Motor 1. Disconnect the motor wiring. • R • w p v OG 2. Loosen the large socket head cap set screw located between the faceplate and the motor coupling. 3. Remove the motor. 4. Ensure damper blade is in the open position with the set I!! IMI=1[10 screw pointing toward the open position on the label. 5. Attach new motor to the coupling;be sure the standoff on motor is positioned in the grommet on the faceplate and AT140 TRANSFORMER the set screw is aligned with the motor shaft hole. ARD CONFIGURED 6. Tighten the set screw. AS POWER OPEN M24048 Fig.3.ARD configured as power open. 3 68-0260-02 - • AUTOMATIC ROUND DAMPER(ARD) Wiring a Single ARD (Power Closed)to a 3. Pinch and push grommet(with hole)to remove. 4. Exchange the positions of the grommet and the plug. Control Panel 5. Manually place damper blade to open position. 6. Place motor on opposite side of damper. (This side M6 CLOSED should now have the grommet with the hole.) • 7. Tighten the cap screw. (Make sure the blade is in the 0 M4 OPEN open position.) 8. If using a zoning panel,change the power wires from • M1 COMMON M1 and M4 to M1 and M6. CO CHECKOUT ! CAUTION ARD CONFIGURED AS POWER CLOSED Possible Equipment Damage M14843 Do not manually open or close the damper as this can damage the actuator. Fig.4.ARD configured as power closed. To check out the ARD: Changing ARD Power Closed to Power Open 1. With 24 Vac applied to the motor leads, observe the 1. Remove power to motor(damper blade in open posi- motor powering the damper to the closed position. tion). 2. When energized,verify that the actuator connection 2. Loosen socket head cap set screw and remove motor. coupling rotates in a clockwise direction(as viewed from 3. Pinch and push grommet(with hole)to remove. the operator base end)and that the damper shaft turns 4. Push out plastic plug. with the coupling. 5. Exchange the positions of the grommet and the plug. 3. With power removed, observe the damper returning to 6. Manually place damper blade in closed position. the normally-open position. 7. Place motor on opposite side of damper. (This side should now have the9 rommet with the hole.) NOTE: To remove power,disconnect one wire from the 8. Tighten thescrew. (Make sure the blade is in the motor. 9 cap closed position.) 9. If using a zoning panel,change the power wires from 4. If the motor does not operate smoothly and without hes- itation throughout the complete opening and closing M1 and M6 to M1 and M4. P P 9 g stroke,examine the damper and the shaft for free Chan in ARD Power Open to Power Closed Irota- tion within perthe duct. Changing p 5. If the full opening and closing is not achieved,check (Factory Default) that the lower adjustment lever is to the extreme left and 1. Disconnect the motor wiring(damper blade in closed the upper lever is to the extreme right. See Fig.2. position). 2. Loosen socket head cap set screw and remove motor. Automation and Control Solutions Honeywell International Inc. Honeywell Limited-Honeywell Limitee 1985 Douglas Drive North 35 Dynamic Drive Golden Valley, MN 55422 Toronto, Ontario M1V4Z9 customer.honeywell.com Honeywell ®U.S.Registered Trademark ®2008 Honeywell International Inc. Printed in U.S.A.on recycled „ j s paper containing at least 10 68-0260-02 M.S. Rev.11-08 �� post-consumer paper fibers.