Report (4)
Jet Fire Protection Page 1 iFLY SKYDIVING TIGARD SECOND FLOOR CALC Date HYDRAULIC CALCULATIONS for Project name: iFLY SKYDIVING TIGARD SECOND FLOOR CALC Location: 10655 SW Greenburg Rd Drawing no: FP2.0 Date: 03/18/15 Design Remote area number: 3 Remote area location: Flight Chamber Occupancy classification: mixed Density: 0.10 -Gpm/SqFt Area of application: 1035-SqFt Coverage per sprinkler: 180 -Sq Ft Type of sprinklers calculated: upright No. of sprinklers calculated: 15 In-rack demand: -GPM Hose streams: 100 -GPM Total water required(including hose streams): 443.555-GPM @ 63.9384- Psi Type of system: Wet Volume of dry or preaction system: -Gal Water supply information Date: Location: - Source: Tualatin Water District Name of contractor: Jet Fire Protection Address: 1935 Silvertom Rd NE/PO Box 7362/Salem, OR 97301 Phone number: 503-363-2334 Name of designer: Authority having jurisdiction: Notes: (Include peaking information or gridded systems here.) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C ' Jet Fit Protection Page 2 iFLY SKYDIVING TIGARD SECOND FLOOR CALC Date • City Water Supply: Demand: Cl -Static Pressure : 109 D1 - Elevation : 14.076 C2- Residual Pressure: 20 D2-System Flow : 343.555 C2- Residual Flow : 8423 D2-System Pressure : 63.938 Hose( Demand ) : 100 D3-System Demand : 443.555 Safety Margin : 44.678 150 140 130 P 120 C1 R110 E 100 S 90 S 80 r u 70 D2 R 60 D3' E 50 40 i 30 C2 20 10 D1 10 Percent Under 1000 2000 3000 4000 5000 6000 7000 8000 9000 FLOW ( NA1.85 ) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary Jet Fire Protection Page 3 iFLY SKYDIVING TIGARD SECOND FLOOR CALC Date Fitting Legend Abbrev. Name 1/2 ' 1 1% 11/2 2 21/2 3 3% 4 5 6 8 10 12 14 16 18 20 24 Bvca B Fly Vic 705 6 6 7 8 12 14 16 18 19 E NFPA 13 90'Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F NFPA 13 45'Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 T NFPA 13 90'Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 ✓ 90'Ell Firelock#001 0 0 0 0 0 3.5 4.3 5 0 6.8 8.5 10 13 0 0 0 0 0 0 0 Zaf Ames 3000SS Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *. The fittings marked with a *show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a *will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 - Flow Summary - NFPA 2007 Jet Fire Protection Page 4 • iFLY SKYDIVING TIGARD SECOND FLOOR CALC Date SUPPLY ANALYSIS Node at Static Residual Available Source Pressure Pressure Flow Pressure Total Demand Required Pressure TEST 109.0 20 8423.0 108.616 443.56 63.938 NODE ANALYSIS Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes HD1 32.5 5.6 10.33 18.0 1 32.5 5.6 11.52 19.01 2 32.5 5.34 11.35 18.0 K=K @ EQ1 3 32.5 11.7 4 32.5 5.6 11.83 19.26 5 32.5 5.6 14.42 21.26 6 32.5 5.6 20.39 25.29 7 32.5 20.68 9 32.5 5.34 15.18 20.82 K=K @ EQ1 10 32.5 5.6 16.3 22.61 11 32.5 20.35 13 32.5 5.6 21.33 25.86 14 32.5 22.37 18 32.5 5.6 22.29 26.44 19 32.5 23.25 • 22 32.5 5.34 16.27 21.55 K=K @ EQ1 23 32.5 5.6 17.46 23.4 24 32.5 21.92 26 32.5 5.6 13.91 20.89 27 32.5 21.22 28 32.5 27.9 30 32.5 31.72 8 32.5 23.38 12 32.5 23.54 15 32.5 23.6 16 32.5 5.34 23.86 26.1 K=K @ EQ1 17 32.5 5.34 24.32 26.35 K=K @ EQ1 20 32.5 24.52 21 32.5 5.34 25.02 26.73 K=K @ EQ1 25 32.5 25.32 29 32.5 29.26 31 32.5 32.93 32 32.5 34.08 FM2 32.0 42.36 FM1 16.0 49.97 TWR 16.0 51.79 BWR 4.0 57.56 UG1 0.0 59.64 UG2 0.0 59.92 TEST 0.0 63.94 100.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams - 2007 Jet Fire Protection Page 5 iFLY SKYDIVING TIGARD SECOND FLOOR CALC Date Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftng's Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqv. Ln. Total Pf/Ft Pf *EQ1 HD1 32.500 5.60 18.00 1 E 2.0 2.500 120 10.332 to T 5.0 7.000 0.0 EQ1 32.500 18.0 1.049 0.0 9.500 0.1071 1.017 Vel = 6.68 0.0 EQ1 18.00 11.349 K Factor= 5.34 *LINE1 1 32.500 5.60 -8.78 1 0.0 6.000 120 11.519 to 0.0 0.0 0.0 2 32.500 -8.78 1.049 0.0 6.000 -0.0283 -0.170 Vel = 3.26 2 32.500 5.34 18.00 1 0.0 11.333 120 11.349 K= K @ EQ1 to 0.0 0.0 0.0 3 32.500 9.22 1.049 0.0 11.333 0.0311 0.352 Vel = 3.42 3 32.500 0.0 1 E 2.0 2.167 120 11.701 to 0.0 2.000 0.0 4 32.500 9.22 1.049 0.0 4.167 0.0310 0.129 Vel = 3.42 4 32.500 5.60 19.26 1 0.0 10.333 120 11.830 . to 0.0 0.0 0.0 5 32.500 28.48 1.049 0.0 10.333 0.2504 2.587 Vel = 10.57 . 5 32.500 5.60 21.26 1 0.0 8.917 120 14.417 to 0.0 0.0 0.0 7 32.500 49.74 1.049 0.0 8.917 0.7021 6.261 Vel = 18.46 • 0.0 7 49.74 20.678 K Factor= 10.94 6 32.500 5.60 25.29 1 0.0 1.417 120 20.394 to 0.0 0.0 0.0 7 32.500 25.29 1.049 0.0 1.417 0.2004 0.284 Vel = 9.39 7 32.500 49.74 1.25 T 6.0 0.833 120 20.678 to 0.0 6.000 0.0 8 32.500 75.03 1.38 0.0 6.833 0.3951 2.700 Vel = 16.09 0.0 8 75.03 23.378 K Factor= 15.52 1 32.500 27.79 1 2E 4.0 6.000 120 11.519 to 0.0 4.000 0.0 26 32.500 27.79 1.049 0.0 10.000 0.2391 2.391 Vel = 10.32 0.0 26 27.79 13.910 K Factor= 7.45 *LINE2 9 32.500 5.34 20.82 1 E 2.0 6.000 120 15.181 K= K@ EQ1 " to 0.0 2.000 0.0 10 32.500 20.82 1.049 0.0 8.000 0.1401 1.121 Vel = 7.73 10 32.500 5.60 22.61 1 0.0 7.417 120 16.302 to 0.0 0.0 0.0 11 32.500 43.43 1.049 0.0 7.417 0.5463 4.052 Vel = 16.12 11 32.500 0.0 1 T 5.0 0.833 120 20.354 to 0.0 5.000 0.0 12 32.500 43.43 1.049 0.0 5.833 0.5462 3.186 Vel = 16.12 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 , Final Calculations - Hazen-Williams Jet Fire Protection Page 6 iFLY SKYDIVING TIGARD SECOND FLOOR CALC Date _ Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt -to or Ftng's Pe ******* Notes ****** Node2 EIev2 Fact Qt Act Eqv. Ln. Total Pf/Ft Pf 0.0 12 43.43 23.540 K Factor= 8.95 *LINE3 13 32.500 5.60 25.86 1 0.0 5.000 120 21.328 to 0.0 0.0 0.0 14 32.500 25.86 1.049 0.0 5.000 0.2092 1.046 Vel = 9.60 14 32.500 0.0 1 T 5.0 0.833 120 22.374 to 0.0 5.000 0.0 15 32.500 25.86 1.049 0.0 5.833 0.2095 1.222 Vel = 9.60 0.0 15 25.86 23.596 K Factor= 5.32 *LINE4 18 32.500 5.60 26.44 1 0.0 4.417 120 22.286 to 0.0 0.0 0.0 19 32.500 26.44 1.049 0.0 4.417 0.2180 0.963 Vel = 9.82 19 32.500 0.0 1 T 5.0 0.833 120 23.249 - to 0.0 5.000 0.0 20 32.500 26.44 1.049 0.0 5.833 0.2181 1.272 Vel = 9.82 0.0 20 26.44 24.521 K Factor= 5.34 *.LINE5 22 32.500 5.34 21.55 1 E 2.0 6.000 120 16.266 K= K @ EQ1 to 0.0 2.000 0.0 23 32.500 21.55 1.049 0.0 8.000 0.1494 1.195 Vel = 8.00 23 32.500 5.60 23.40 1 0.0 7.667 120 17.461 to 0.0 0.0 0.0 24 32.500 44.95 1.049 0.0 7.667 0.5821 4.463 Vel = 16.69 24 32.500 0.0 1 T 5.0 0.833 120 21.924 to 0.0 5.000 0.0 25 32.500 44.95 1.049 0.0 5.833 0.5822 3.396 Vel = 16.69 0.0 25 44.95 25.320 K Factor= 8.93 *LINE6 26 32.500 5.60 48.67 1 0.0 10.833 120 13.910 to 0.0 0.0 0.0 - 27 32.500 48.67 1.049 0.0 10.833 0.6744 7.306 Vel = 18.07 27 32.500 0.0 1 E 2.0 7.917 120 21.216 to 0.0 2.000 0.0 •28 32.500 48.67 1.049 0.0 9.917 0.6744 6.688 Vel = 18.07 28 32.500 0.0 1.25 E 3.0 18.500 120 27.904 •to 0.0 3.000 0.0 30 32.500 48.67 1.38 0.0 21.500 0.1774 3.814 Vel = 10.44 30 32.500 0.0 1.25 T 6.0 0.833 120 31.718 to 0.0 6.000 0.0 31 32.500 48.67 1.38 0.0 6.833 0.1774 1.212 Vel = 10.44 0.0 31 48.67 32.930 K Factor= 8.48 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Jet Fire Protection Page 7 iFLY SKYDIVING TIGARD SECOND FLOOR CALC Date Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftng's Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqv. Ln. Total Pf/Ft Pf • *MAIN 8 32.500 75.03 2.5 0.0 9.583 120 23.378 to 0.0 0.0 0.0 12 32.500 75.03 2.635 0.0 9.583 0.0169 0.162 Vel = 4.41 12 32.500 43.43 2.5 0.0 1.417 120 23.540 to 0.0 0.0 0.0 15 32.500 118.46 2.635 0.0 1.417 0.0395 0.056 Vel = 6.97 15 32.500 25.86 2.5 0.0 4.583 120 23.596 to 0.0 0.0 0.0 16 32.500 144.32 2.635 0.0 4.583 0.0567 0.260 Vel = 8.49 16 32.500 5.34 26.10 2.5 0.0 6.000 120 23.856 K= K @ EQ1 to 0.0 0.0 0.0 17 32.500 170.42 2.635 0.0 6.000 0.0772 0.463 Vel = 10.03 17 32.500 5.34 26.35 2.5 0.0 2.000 120 24.319 K= K @ EQ1 to 0.0 0.0 0.0 20 32.500 196.77 2.635 0.0 2.000 0.1010 0.202 Vel = 11.58 . 20 32.500 26.44 2.5 0.0 3.917 120 24.521 - to 0.0 0.0 0.0 21 32.500 223.21 2.635 0.0 3.917 0.1271 0.498 Vel = 13.13 . 21 32.500 5.34 26.72 2.5 0.0 1.917 120 25.019 K= K @ EQ1 . to 0.0 0.0 0.0 25 32.500 249.93 2.635 0.0 1.917 0.1570 0.301 Vel = 14.70 - 25 32.500 44.95 2.5 0.0 18.500 120 25.320 to 0.0 0.0 0.0 29 32.500 294.88 2.635 0.0 18.500 0.2130 3.940 Vel = 17.35 29 32.500 0.0 2.5 V 5.903 11.333 120 29.260 to 0.0 5.903 0.0 31 32.500 294.88 2.635 0.0 17.236 0.2129 3.670 Vel = 17.35 31 32.500 48.68 2.5 0.0 4.083 120 32.930 to 0.0 0.0 0.0 32 32.500 343.56 2.635 0.0 4.083 0.2826 1.154 Vel = 20.21 32 32.500 0.0 2.5 2V 11.807 8.500 120 34.084 to Bvca 8.237 20.044 0.217 FM2 32 343.56 2.635 0.0 28.544 0.2825 8.063 Vel = 20.21 FM2 32 0.0 4 V 8.954 16.000 120 42.364 to 0.0 8.954 6.930 FM1 16 343.56 4.26 0.0 24.954 0.0273 0.680 Vel = 7.73 FM1 16 0.0 4 5V 44.768 22.000 120 49.974 to 0.0 44.768 0.0 TWR 16 343.56 4.26 0.0 66.768 0.0272 1.817 Vel = 7.73 TWR 16 0.0 4 V 8.954 12.000 120 51.791 to 0.0 8.954 5.197 BWR 4 343.56 4.26 0.0 20.954 0.0273 0.571 Vel = 7.73 BWR 4 0.0 4 V 8.954 4.000 120 57.559 to 0.0 8.954 1.732 UG1 0 343.56 4.26 0.0 12.954 0.0273 0.353 Vel = 7.73 UG1 0 0.0 4 0.0 10.000 120 59.644 to 0.0 0.0 0.0 UG2 0 343.56 4.26 0.0 10.000 0.0273 0.273 Vel = 7.73 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 . Final Calculations - Hazen-Williams Jet Fire Protection Page 8 iFLY SKYDIVING TIGARD SECOND FLOOR CALC Date • Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt • to or Ftng's Pe ******* Notes ****** ' Node2 Elev2 Fact Qt Act Eqv. Ln. Total Pf/Ft Pf UG2 0 0.0 6 Zaf 0.0 321.000 140 59.917 to G 4.304 64.556 2.712 * * Fixed Loss= 2.712 TEST 0 343.56 6.16 E 20.084 385.556 0.0034 1.309 Vel = 3.70 4F 40.168 100.00 Qa = 100.00 TEST 443.56 63.938 K Factor= 55.47 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 low et isWIN JJ jet 4 G - Y _ r �„ r as MAI. ELECTRICAL HEATING EIRE PROTECTION PLUMBING MAINTENANCE E 'ODD PRODUCTS "Solutions for a streamlined project" /<<,' PROXG�NEF9 �b� 54 9Pi/ %/l /00, ER; 15, 20 \(< Fy CYN N SSP' EXPIRES: 06-30-2016 JET FIRE PROTECTION 1935 SILVERTON RD SALEM, OR 97301 503-363-2334 Job Name : iFLY SKYDIVING TIGARD PENTHOUSE CALC Building : FP5.0 Location : 10655 SW Greenburg Rd System : 1 Contract : 15-0125 Data File : iFLY PENTHOUSE CALC.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 JET FIRE PROTECTION Page 1 iFLY SKYDIVING TIGARD PENTHOUSE CALC Date - HYDRAULIC CALCULATIONS for Project name: iFLY SKYDIVING TIGARD SECOND FLOOR CALC Location: 10655 SW Greenburg Rd Drawing no: FP5.0 Date: 03/18/15 Design Remote area number: 1 Remote area location: MECH PENTHOUSE Occupancy classification: MISC Density: 0.20-Gpm/SqFt Area of application: 968-SqFt Coverage per sprinkler: 108 -Sq Ft Type of sprinklers calculated: UPRIGHT No. of sprinklers calculated: 9 In-rack demand: -GPM Hose streams: 100-GPM Total water required(including hose streams): 457.92-GPM @ 82.82- Psi Type of system: Wet Volume of dry or preaction system: -Gal Water supply information Date: Location: - - Source: Tualatin Water District Name of contractor: Jet Fire Protection Address: 1935 Silvertom Rd NE/PO Box 7362/Salem, OR 97301 Phone number: 503-363-2334 Name of designer: Authority having jurisdiction: Notes:(Include peaking information or gridded systems here.) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C • • JET FIRE PROTECTION Page 2 iFLY SKYDIVING TIGARD PENTHOUSE CALC Date ► City Water Supply: Demand: Cl -Static Pressure : 109 D1 - Elevation : 29.018 C2-Residual Pressure: 20 D2-System Flow : 279.751 C2-Residual Flow : 8423 D2-System Pressure : 80.861 Hose( Demand ) : 100 D3-System Demand : 379.751 Safety Margin : 27.851 150 140 130 P 120 Cl R 110 E 100 S 90 D2 S 80 31 U 70 D C • R 60 E 50 40 30 o D1 C2 20 • 10 10 Percent Under 1000 2000 3000 4000 5000 6000 7000 8000 9000 FLOW ( NA1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary JET FIRE PROTECTION Page 3 iFLY SKYDIVING TIGARD PENTHOUSE CALC Date Fitting Legend Abbrev. Name 1/2 '/ 1 1% 11/2 2 212 3 3% 4 5 6 8 10 12 14 16 18 20 24 E NFPA 13 90'Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F NFPA 13 45'Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 T NFPA 13 90'Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 ✓ 90'Ell Firelock#001 0 0 0 0 0 3.5 4.3 5 0 6.8 8.5 10 13 0 0 0 0 0 0 0 Zaf Ames 3000SS Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *. The fittings marked with a *show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a*will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Summary - NFPA 2007 JET FIRE PROTECTION Page 4 • iFLY SKYDIVING TIGARD PENTHOUSE CALC Date SUPPLY ANALYSIS - Node at Static Residual Available Source Pressure Pressure Flow Pressure Total Demand Required Pressure TEST 109.0 20 8423.0 108.712 379.75 80.861 NODE ANALYSIS Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes 1 67.0 5.6 7.17 14.99 2 67.0 5.6 7.72 15.56 3 67.0 5.6 9.76 17.49 4 67.0 5.6 14.48 21.31 5 67.0 15.44 7 67.0 5.6 7.28 15.11 8 67.0 5.6 7.84 15.68 9 67.0 5.6 9.91 17.63 10 67.0 5.6 14.69 21.47 11 67.0 15.67 13 67.0 5.6 7.81 15.65 14 67.0 5.6 8.4 16.23 - 15 67.0 5.6 10.61 18.24 16 67.0 5.6 15.71 22.2 17 67.0 16.76 - 19 67.0 5.6 14.54 21.36 20 67.0 5.6 15.6 22.12 21 67.0 5.6 19.52 24.74 22 67.0 20.46 6 67.0 18.75 12 67.0 19.02 18 67.0 20.32 23 67.0 23.66 FM4 67.0 44.65 FM3 54.0 50.97 FM2 32.0 60.91 FM1 16.0 68.14 TWR 16.0 69.38 BWR 4.0 74.97 UG1 0.0 76.94 UG2 0.0 77.13 TEST 0.0 80.86 100.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams - 2007 JET FIRE PROTECTION Page 5 iFLY SKYDIVING TIGARD PENTHOUSE CALC Date • - Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftng's Pe ******* Notes ******- Node2 Elev2 Fact Qt Act Eqv. Ln. Total Pf/Ft Pf *LINE1 1 67 5.60 14.99 1 0.0 7.167 120 7.169 to 0.0 0.0 0.0 2 67 14.99 1.049 0.0 7.167 0.0763 0.547 Vel = 5.56 2 67 5.60 15.56 1 0.0 7.167 120 7.716 to 0.0 0.0 0.0 3 67 30.55 1.049 0.0 7.167 0.2849 2.042 Vel = 11.34 3 67 5.60 17.49 1 0.0 7.167 120 9.758 to 0.0 0.0 0.0 4 67 48.04 1.049 0.0 7.167 0.6584 4.719 Vel = 17.83 4 67 5.60 21.31 1.25 0.0 2.833 120 14.477 to 0.0 0.0 0.0 5 67 69.35 1.38 0.0 2.833 0.3417 0.968 Vel = 14.88 5 67 0.0 1.25 T 6.0 0.667 120 15.445 to E 3.0 9.000 0.0 6 67 69.35 1.38 0.0 9.667 0.3415 3.301 Vel = 14.88 0.0 6 69.35 18.746 K Factor= 16.02 *LINE2 • 7 67 5.60 15.11 1 0.0 7.167 120 7.280 to 0.0 0.0 0.0 8 67 15.11 1.049 0.0 7.167 0.0774 0.555 Vel = 5.61 8 67 5.60 15.67 1 0.0 7.167 120 7.835 to 0.0 0.0 0.0 9 67 30.78 1.049 0.0 7.167 0.2890 2.071 Vel = 11.43 9 67 5.60 17.63 1 0.0 7.167 120 9.906 to 0.0 0.0 0.0 10 67 48.41 1.049 0.0 7.167 0.6678 4.786 Vel = 17.97 10 67 5.60 21.47 1.25 0.0 2.833 120 14.692 to 0.0 0.0 0.0 11 67 69.88 1.38 0.0 2.833 0.3463 0.981 Vel = 14.99 11 67 0.0 1.25 T 6.0 0.667 120 15.673 to E 3.0 9.000 0.0 12 67 69.88 1.38 0.0 9.667 0.3463 3.348 Vel = 14.99 0.0 12 69.88 19.021 K Factor= 16.02 *LINE3 13 67 5.60 15.65 1 0.0 7.167 120 7.807 to 0.0 0.0 0.0 14 67 15.65 1.049 0.0 7.167 0.0827 0.593 Vel = 5.81 14 67 5.60 16.23 1 0.0 7.167 120 8.400 _ to 0.0 0.0 0.0 15 67 31.88 1.049 0.0 7.167 0.3082 2.209 Vel = 11.83 15 67 5.60 18.24 1 0.0 7.167 120 10.609 to 0.0 0.0 0.0 16 67 50.12 1.049 0.0 7.167 0.7119 5.102 Vel = 18.61 16 67 5.60 22.19 1.25 0.0 2.833 120 15.711 to 0.0 0.0 0.0 17 67 72.31 1.38 0.0 2.833 0.3692 1.046 Vel = 15.51 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams JET FIRE PROTECTION Page 6 iFLY SKYDIVING TIGARD PENTHOUSE CALC Date Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftng's Pe ******* Notes ****** - Node2 Elev2 Fact Qt Act Eqv. Ln. Total Pf/Ft Pf 17 67 0.0 1.25 T 6.0 0.667 120 16.757 to E 3.0 9.000 0.0 18 67 72.31 1.38 0.0 9.667 0.3690 3.567 Vel = 15.51 0.0 18 72.31 20.324 K Factor= 16.04 *LINE4 19 67 5.60 21.36 1 0.0 7.167 120 14.542 to 0.0 0.0 0.0 20 67 21.36 1.049 0.0 7.167 0.1471 1.054 Vel = 7.93 20 67 5.60 22.11 1 0.0 7.167 120 15.596 to 0.0 0.0 0.0 21 67 43.47 1.049 0.0 7.167 0.5471 3.921 Vel = 16.14 21 67 5.60 24.74 1.25 0.0 2.833 120 19.517 to 0.0 0.0 0.0 22 67 68.21 1.38 0.0 2.833 0.3311 0.938 Vel = 14.63 - 22 67 0.0 1.25 T 6.0 0.667 120 20.455 to E 3.0 9.000 0.0 23 67 68.21 1.38 0.0 9.667 0.3312 3.202 Vel = 14.63 0.0 23 68.21 23.657 K Factor= 14.02 *MAIN 6 67 69.35 2 0.0 7.083 120 18.746 to 0.0 0.0 0.0 12 67 69.35 2.157 0.0 7.083 0.0388 0.275 Vel = 6.09 12 67 69.88 2 0.0 9.250 120 19.021 to 0.0 0.0 0.0 18 67 139.23 2.157 0.0 9.250 0.1409 1.303 Vel = 12.22 18 67 72.31 2 0.0 10.917 120 20.324 to 0.0 0.0 0.0 23 67 211.54 2.157 0.0 10.917 0.3053 3.333 Vel = 18.57 23 67 68.21 2 0.0 41.000 120 23.657 to 0.0 0.0 0.0 FM4 67 279.75 2.157 0.0 41.000 0.5121 20.995 Vel = 24.56 FM4 67 0.0 4 V 8.954 28.000 120 44.652 to 0.0 8.954 5.630 FM3 54 279.75 4.26 0.0 36.954 0.0186 0.688 Vel = 6.30 FM3 54 0.0 4 0.0 22.000 120 50.970 to 0.0 0.0 9.528 - FM2 32 279.75 4.26 0.0 22.000 0.0186 0.410 Vel = 6.30 FM2 32 0.0 4 0.0 16.000 120 60.908 to 0.0 0.0 6.930 - FM1 16 279.75 4.26 0.0 16.000 0.0186 0.298 Vel = 6.30 FM1 16 0.0 4 5V 44.768 22.000 120 68.136 to 0.0 44.768 0.0 TWR 16 279.75 4.26 0.0 66.768 0.0186 1.243 Vel = 6.30 TWR 16 0.0 4 V 8.954 12.000 120 69.379 to 0.0 8.954 5.197 BWR 4 279.75 4.26 0.0 20.954 0.0186 0.390 Vel = 6.30 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams JET FIRE PROTECTION Page 7 iFLY SKYDIVING TIGARD PENTHOUSE CALC Date Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftng's Pe ******* Notes ******- Node2 Elev2 Fact Qt Act Eqv. Ln. Total Pf/Ft Pf BWR 4 0.0 4 V 8.954 4.000 120 74.966 to 0.0 8.954 1.732 UG1 0 279.75 4.26 0.0 12.954 0.0187 0.242 Vel = 6.30 UG1 0 0.0 4 0.0 10.000 120 76.940 to 0.0 0.0 0.0 UG2 0 279.75 4.26 0.0 10.000 0.0186 0.186 Vel = 6.30 UG2 0 0.0 6 Zaf 0.0 321.000 140 77.126 to G 4.304 64.556 2.840 * * Fixed Loss=2.84 TEST 0 279.75 6.16 E 20.084 385.556 0.0023 0.895 Vel = 3.01 4F 40.168 100.00 Qa = 100.00 TEST 379.75 80.861 K Factor= 42.23 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 jet NiAi 26 71315 %al ELECTRICAL HEATING FIRE PROTECTION PLUMBING MAINTENANCE WOOD PRODUCTS "Solutions for a streamlined pjest" �?' 0 PROA- �� �\GIN4�si0 Qi / 5 4 ' 19- cb IIRFAV r, v.,0'15,VC)PJ�� LYNN S'( EXPIRES: 06-30-2016 Jet Fire Protection 1935 Silvertom Rd NE PO Box 7362 Salem, OR 97301 503-363-2334 Job Name : iFLY SKYDIVING TIGARD THIRD FLOOR CALC Building : FP3.0 Location : 10655 SW Greenburg Rd System : 2 Contract : 15-0125 Data File : iFLY THIRD FLOOR CALC.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Jet Fire Protection Page 1 iFLY SKYDIVING TIGARD THIRD FLOOR CALC Date HYDRAULIC CALCULATIONS for Project name: iFLY SKYDIVING TIGARD SECOND FLOOR CALC Location: 10655 SW Greenburg Rd Drawing no: FP3.0 Date: 03/18/15 Design Remote area number: 2 Remote area location: HALL 2 AREA Occupancy classification: mixed Density: 0.10-Gpm/SqFt Area of application: 945-SqFt Coverage per sprinkler: 100 -SqFt Type of sprinklers calculated: PENDANT No. of sprinklers calculated: 15 In-rack demand: -GPM Hose streams: 100 -GPM Total water required(including hose streams): 331.62 -GPM @ 71.090 - Psi Type of system: Wet Volume of dry or preaction system: -Gal Water supply information Date: Location: Source: Tualatin Water District Name of contractor: Jet Fire Protection Address: 1935 Silvertom Rd NE/PO Box 7362/Salem, OR 97301 Phone number: 503-363-2334 Name of designer: Authority having jurisdiction: Notes:(Include peaking information or gridded systems here.) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C Jet Fire Protection Page 2 iFLY SKYDIVING TIGARD THIRD FLOOR CALC Date City Water Supply: Demand: Cl -Static Pressure : 109 D1 -Elevation : 23.387 C2-Residual Pressure: 20 D2-System Flow : 231.621 C2-Residual Flow : 8423 D2-System Pressure : 71.090 Hose( Demand ) : 100 D3-System Demand : 331.621 Safety Margin : 37.686 150 140 130 P 120 - C1 R 110 E 100 S 90 S 80 D2 U 70 R 60 D3 E 50 40 30 20 D1 _ _ C2 • 10 i• • 10 Percent Under 1000 2000 3000 4000 5000 6000 7000 8000 9000 FLOW ( NA1.85 ) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary Jet Fire Protection Page 3 iFLY SKYDIVING TIGARD THIRD FLOOR CALC Date Fitting Legend Abbrev. Name '/2 % 1 1% 1% 2 21/2 3 3% 4 5 6 8 10 12 14 16 18 20 24 Bvca B Fly Vic 705 6 6 7 8 12 14 16 18 19 E NFPA 13 90'Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F NFPA 13 45'Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 T NFPA 13 90'Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 ✓ 90'Ell Firelock#001 0 0 0 0 0 3.5 4.3 5 0 6.8 8.5 10 13 0 0 0 0 0 0 0 Zaf Ames 3000SS Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *. The fittings marked with a *show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a *will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 - Flow Summary- NFPA 2007 Jet Fire Protection Page 4 • iFLY SKYDIVING TIGARD THIRD FLOOR CALC Date SUPPLY ANALYSIS Node at Static Residual Available Source Pressure Pressure Flow Pressure Total Demand Required Pressure TEST 109.0 20 8423.0 108.776 331.62 71.09 NODE ANALYSIS Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes HD1 54.0 5.6 7.0 14.82 1 54.0 5.11 12.45 18.01 K=K @ EQ1 2 54.0 5.11 13.38 18.67 K=K @ EQ1 3 54.0 5.11 15.3 19.97 K=K @ EQ1 6 54.0 5.11 8.42 14.82 K=K @ EQ1 7 54.0 5.11 9.17 15.46 K=K @ EQ1 8 54.0 5.11 11.6 17.39 K=K @ EQ1 9 54.0 5.11 11.66 17.44 K=K @ EQ1 10 54.0 5.11 13.02 18.42 K=K @ EQ1 14 54.0 5.11 12.78 18.26 K=K @ EQ1 15 54.0 5.11 13.44 18.72 K=K @ EQ1 19 54.0 5.11 17.15 21.15 K=K @ EQ1 22 54.0 5.11 10.2 16.31 K=K @ EQ1 23 54.0 5.11 11.09 17.0 K=K @ EQ1 24 54.0 15.97 4 54.0 16.57 11 54.0 16.79 13 54.0 17.52 16 54.0 18.34 20 54.0 18.69 25 54.0 25.08 26 54.0 34.11 27 54.0 41.5 FM3 54.0 42.07 FM2 32.0 52.0 FM1 16.0 59.14 TWR 16.0 60.02 BWR 4.0 65.49 UG1 0.0 67.39 UG2 0.0 67.52 TEST 0.0 71.09 100.0 • Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams - 2007 Jet Fire Protection Page 5 iFLY SKYDIVING TIGARD THIRD FLOOR CALC Date Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftng's Pe ******* Notes ******- - Node2 Elev2 Fact Qt Act Eqv. Ln. Total Pf/Ft Pf *EQ1 HD1 54 5.60 14.82 1 E 2.0 12.000 120 7.000 to T 5.0 7.000 0.0 EQ1 54 14.82 1.049 0.0 19.000 0.0747 1.419 Vel = 5.50 0.0 EQ1 14.82 8.419 K Factor= 5.11 *LINE1 1 54 5.11 18.01 1 0.0 8.667 120 12.446 K= K @ EQ1 to 0.0 0.0 0.0 2 54 18.01 1.049 0.0 8.667 0.1073 0.930 Vel = 6.69 2 54 5.11 18.68 1 T 5.0 3.000 120 13.376 K= K @ EQ1 to 0.0 5.000 0.0 4 54 36.69 1.049 0.0 8.000 0.3998 3.198 Vel = 13.62 0.0 4 36.69 16.574 K Factor= 9.01 3 54 5.11 19.97 1 T 5.0 4.833 120 15.298 K= K @ EQ1 to 0.0 5.000 0.0 4 54 19.97 1.049 0.0 9.833 0.1298 1.276 Vel = 7.41 0.0 ` 4 19.97 16.574 K Factor= 4.91 *LINE2 6 54 5.11 14.82 1 E 2.0 8.000 120 8.419 K= K @ EQ1 to 0.0 2.000 0.0 7 54 14.82 1.049 0.0 10.000 0.0747 0.747 Vel = 5.50 7 54 5.11 15.46 1 0.0 8.667 120 9.166 K= K @ EQ1 to 0.0 0.0 0.0 8 54 30.28 1.049 0.0 8.667 0.2803 2.429 Vel = 11.24 8 54 5.11 17.38 1 T 5.0 3.000 120 11.595 K= K @ EQ1 to 0.0 5.000 0.0 11 54 47.66 1.049 0.0 8.000 0.6489 5.191 Vel = 17.69 0.0 11 47.66 16.786 K Factor= 11.63 9 54 5.11 17.44 1 E 2.0 11.417 120 11.662 K= K @ EQ1 to 0.0 2.000 0.0 10 54 17.44 1.049 0.0 13.417 0.1010 1.355 Vel = 6.47 10 54 5.11 18.42 1 T 5.0 4.833 120 13.017 K= K @ EQ1 to 0.0 5.000 0.0 11 54 35.86 1.049 0.0 9.833 0.3833 3.769 Vel = 13.31 0.0 11 35.86 16.786 K Factor= 8.75 *LINE3 L 14 54 5.11 18.26 1 0.0 6.000 120 12.782 K= K @ EQ1 to 0.0 0.0 0.0 15 54 18.26 1.049 0.0 6.000 0.1098 0.659 Vel = 6.78 15 54 5.11 18.72 1 T 5.0 7.083 120 13.441 K= K @ EQ1 to 0.0 5.000 0.0 • 16 54 36.98 1.049 0.0 12.083 0.4057 4.902 Vel = 13.73 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 -Final Calculations - Hazen-Williams Jet Fire Protection Page 6 ' iFLY SKYDIVING TIGARD THIRD FLOOR CALC Date Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt - to or Ftng's Pe ******* Notes ****** - Node2 Elev2 Fact Qt Act Eqv. Ln. Total Pf/Ft Pf 0.0 16 36.98 18.343 K Factor= 8.63 *LINE4 19 54 5.11 21.15 1 T 5.0 5.667 120 17.152 K= K @ EQ1 to 0.0 5.000 0.0 20 54 21.15 1.049 0.0 10.667 0.1443 1.539 Vel = 7.85 0.0 20 21.15 18.691 K Factor= 4.89 *LINE5 22 54 5.11 16.31 1 0.0 9.917 120 10.204 K= K @ EQ1 to 0.0 0.0 0.0 23 54 16.31 1.049 0.0 9.917 0.0892 0.885 Vel = 6.05 23 54 5.11 17.00 1 0.0 14.583 120 11.089 K= K @ EQ1 to 0.0 0.0 0.0 24 54 33.31 1.049 0.0 14.583 0.3344 4.877 Vel = 12.37 24 54 0.0 1 T 5.0 20.250 120 15.966 to E 2.0 7.000 0.0 25 54 33.31 1.049 0.0 27.250 0.3345 9.114 Vel = 12.37 0.0 25 33.31 25.080 K Factor= 6.65 *MAIN 4 54 56.66 2 0.0 7.917 120 16.574 to 0.0 0.0 0.0 11 54 56.66 2.157 0.0 7.917 0.0268 0.212 Vel = 4.97 11 54 83.52 2 0.0 5.167 120 16.786 to 0.0 0.0 0.0 13 54 140.18 2.157 0.0 5.167 0.1424 0.736 Vel = 12.31 13 54 0.0 2 0.0 5.750 120 17.522 to 0.0 0.0 0.0 16 54 140.18 2.157 0.0 5.750 0.1428 0.821 Vel = 12.31 16 54 36.98 2 0.0 1.583 120 18.343 to 0.0 0.0 0.0 20 54 177.16 2.157 0.0 1.583 0.2198 0.348 Vel = 15.55 20 54 21.15 2 0.0 23.583 120 18.691 to 0.0 0.0 0.0 25 54 198.31 2.157 0.0 23.583 0.2709 6.389 Vel = 17.41 25 54 33.31 2 0.0 25.000 120 25.080 .to 0.0 0.0 0.0 _26 54 231.62 2.157 0.0 25.000 0.3611 9.028 Vel = 20.34 26 54 0.0 2 V 4.307 16.167 120 34.108 to 0.0 4.307 0.0 27 54 231.62 2.157 0.0 20.474 0.3611 7.394 Vel = 20.34 27 54 0.0 4 2V 17.907 14.500 120 41.502 to Bvca 10.534 28.441 0.0 FM3 54 231.62 4.26 0.0 42.941 0.0131 0.563 Vel = 5.21 FM3 54 0.0 4 V 8.954 22.000 120 42.065 to 0.0 8.954 9.528 FM2 32 231.62 4.26 0.0 30.954 0.0131 0.407 Vel = 5.21 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams a Jet Fire Protection Page 7 • iFLY SKYDIVING TIGARD THIRD FLOOR CALC Date - t Node1 EIev1 K Qa Nom Fitting Pipe CFact Pt to or Ftng's Pe ******* Notes ****** - Node2 Elev2 Fact Qt Act Eqv. Ln. Total Pf/Ft Pf FM2 32 0.0 4 0.0 16.000 120 52.000 to 0.0 0.0 6.930 FM 1 16 231.62 4.26 0.0 16.000 0.0131 0.210 Vel = 5.21 FM1 16 0.0 4 5V 44.768 22.000 120 59.140 to 0.0 44.768 0.0 TWR 16 231.62 4.26 0.0 66.768 0.0131 0.876 Vel = 5.21 TWR 16 0.0 4 V 8.954 12.000 120 60.016 to 0.0 8.954 5.197 BWR 4 231.62 4.26 0.0 20.954 0.0132 0.276 Vel = 5.21 BWR 4 0.0 4 V 8.954 4.000 120 65.489 to 0.0 8.954 1.732 UG1 0 231.62 4.26 0.0 12.954 0.0131 0.170 Vel = 5.21 UG1 0 0.0 4 0.0 10.000 120 67.391 to 0.0 0.0 0.0 UG2 0 231.62 4.26 0.0 10.000 0.0131 0.131 Vel = 5.21 UG2 0 0.0 6 Zaf 0.0 321.000 140 67.522 to G 4.304 64.556 2.936 ** Fixed Loss=2.936 TEST 0 231.62 6.16 E 20.084 385.556 0.0016 0.632 Vel = 2.49 4F 40.168 • 100.00 Qa = 100.00 TEST 331.62 71.090 K Factor= 39.33 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087