Loading...
Report (35) f$ 2-v -Ooo,/ (, (y'-f5— 3 4) C cac4" S A-InBuildingRiser Series IBR s AME S In-Building Risers It d *. t_ FIRE Sizes: 4" - 10" (100-250mm) } LEAD FREE* 1. TEST CAI'. `I m i • Building Floor BuildingBuilding• perimeterewall :- NATIAZINSI rt � Qat Flow I Features Series IBR In-Building Risers are used to connect the main fire supply to • Cost savings the building overhead fire system. The fitting passes under the foundation • Corrosion resistant stainless steel without joints and extends up through the floor. Provided with installation construction,type 304 tabs, the unit has a CIPS (Cast Iron Pipe Size) coupler for easy connec- • Ease of installation and light weight tion to the underground supply(AWWA C900 PVC and Ductile Iron Pipe) allows one person to position and and industry standard grooved-end connection (AWWA C606) on the handle the riser building side for easy connection to the overhead fire sprinkler system. • Minimal site preparation;joint restraint one-piece construction reduces time Ames In-Building Risers are precision engineered and manufactured to and labor; no missing parts, no leaks; provide exceptional reliability and reduce installation time& labor costs easily identifiable for approvals associated with field assembly. In accordance with NFPA 24-2007, the • Includes Test Cap and Coupler UL/FM approved In-Building Risers replace numerous fittings, elbows • UL/FM approved &spools and reduces the possibility of leaks or failure in comparison to • Sizes: available in 4"-10" traditional installation methods and materials. Factory tested integrity (100-250mm)with various ensures the highest quality installation. The use of stainless steel signifi- lengths to meet all local requirements cantly increases the reliability and life of the riser. • Designed to meet NFPA 24-2007 Section 10.6.5 *The wetted surface of this product contacted by • AWWA C900 Inlet/DIP consumable water contains less than one quarter • AWWA C606 Outlet of one percent(0.25%)of lead by weight. Job Name Contractor Job Location Approval • Engineer Contractor's P.O.No. Approval Representative • Ames product specifications in U.S.customary units and metric are approximate and are provided for reference only.For precise measurements,please contact Ames Technical Service.Ames reser to change or modify product design,construction,specifications,or materials without prior notice and without incurring any obligation to make such changes and modifications on Ames prodi'- subsequently sold. www.amesfirewater.com , 3 Specifications Standards In-Building Riser shall be installed as indicated on the NFPA — Designed to allow the contractor to conform plans. Riser shall be composed of a single extended to NFPA 24-2007 Section 10.6.5: 90 degree fitting of fabricated 304 stainless steel tub- Where a riser is close to building foundations, under- ing, maximum working pressure 200psi (14 bar). The ground fittings of proper design and type shall be used to fitting shall have a grooved-end connection on the avoid pipe joints being located under the foundations. outlet (building) side and a CIPS coupler on the inlet NFPA 24-2007, 10.1.1, 10.6.7 (underground) side. The grooved end shall include a coupler and cap to facilitate testing of the underground I. piping. The In-Building Riser shall be an Ames Fire & Waterworks Series IBR. End Connections Horizontal End: Mates with Ductile Iron Pipe and Approvals AWWA C900 Pipe (PVC Pipe with Ductile Iron Pipe Fittings FM class 1920 Equivalent OD's) UL HKQA(4"-10") Utilizes Gasket conforming to UL 157 with "Lock in" ® ® gasket configuration SIZE(DN) MATING PIPE OD in. mm in. mm Dimensions — Weights 4 100 4.8 122 6 150 6.9 175 -- H -A 8 200 9.1 230 V Grooved End 10 250 11.1 282 _ (Flange Optional) B 0 Vertical End: Meets AWWA C-606 dimensions for roll grooved pipe Meets AWWA C-207 class D for flanges Ratings CIPS Coupling Meets AWWA C-900 pressure class 200, DR 14 Pipe Tie-Rod Bracket Testing Welds are 100% leak tested at the factory N C s I SIZE DESIGN PROOF PRESSURE in. mm psi bar 4 100 1000 70 6 150 1000 70 A(OD) B C 8 200 800 56 in. mm in. mm ft. cm ft. cm lbs. kg 10 250 800 56 4 100 41 114 6 183 6 183 71 32 6 150 65/8 168 6 183 6 183 98 44 8 200 8% 219 6 183 6 183 129 59 10 250 103/4 273 6 183 6 183 202 92 Consult factory for custom leg dimensions. IMPORTANT:Inquire with governing authorities for local installation requirements. A. gU�p,Nc �� r A M E S ''''MB'''' 9001-2000 " FIRE&WATERWORKS www.amesfirewater.com CERTIFIED A Watts Water Technologies Company USA: Backflow-1427 N.Market Blvd•Suite#9•Sacramento,CA 95834•T:916-928-0123•F:916-928-9333 Control Valves-18550 Hansen Road•Houston,TX 77075•T:713-943-0688•F:713-944-9445 Canada: 5435 North Service Rd.•Burlington,ONT.L7L 5H7.T:905-332-4090•F:905-332-7068 ES A-InBuildingRiser 0935 ©2009 Ames Fire&Waterworks , ,5 CARBONEFPP FJ G�I FireLock® Butterfly utterfly Valve `Ous ® VdSS ,31. SERIES 705 WITH WEATHERPROOF ACTUATOR The Series 705 Butterfly Valve features a weatherproof actuator housing Approved for pfig indoor or outdoor use,a ductile iron body and disc with Nitrile seats. Designed for fire "� protection services only.Victaulic FireLock Series 705 Butterfly Valve is cULus Listed, 11 LPCB Listed, FM and VdS Approved for 300 psi/2068 kPa service. Contact Victaulic for details of agency approvals. t APPROVALS AND LISTINGS Approval/Listing Service Pressures Series 705 Butterfly Valve cULus FM 2750mm up to 300psi/2068kPa n/a pOCR si up to 300psi/2068kPa up to 300psi/2068kPa 2 1/2/65mm up to 300psi/2068kPaup to 300psi/2068kPa n/a upto 3 00psi/2068kPa 76.1 mm up to 300psi/2068kpa up to 300psi/2068kPa up to 300psi/2068kPa = up to 300psi/2068kPa 3/80mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 4'/100mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 57125mm up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 139.7mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 67150mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kpa up to 300psi/2068kPa 165.1mm up to 300psi/2068kpa up to 300psi/2068kPa n/a up to 300psi/2068kPa 8/200mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 10'/250mm up to 300psi/2068kPa up to 300psi/2068kPa n/a 127300mm u.to 300.si/2068kPa u•to 300•si/2068kPa n/a up to 300psi/2068kPa u•to 300•si/2068kPa JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2010 VICTAULIC COMPANY.ALL RIGHTS RESERVED. uct.a LJI11C° REV C 10.81 IPS CARBON STEEL PIPE—FIRE PROTECTION VALVES FtreLoc.. , Butterfly SERIES 705 WITH WEATHERPROOF ACTUATOR MATERIAL SPECIFICATIONS Body: Ductile iron conforming to ASTM A-536,grade 65-45-12 End Face, 2—6750— 150mm: Ductile iron conforming to ASTM A-536,grade 65-45-12 Seal Retainer,8— 127200—300 mm: Ductile iron conforming to ASTM A-536,grade 65-45-12 Coating: Black alkyd enamel Disc: Ductile iron conforming to ASTM A-536,grade 65-45-12,with electroless nickel coating con- forming to ASTM B-733 Seat: • Grade"T3"Nitrile Stems:416 stainless steel conforming to ASTM A-582 Stem Seal Cartridge:C36000 brass Bearings:Stainless Steel with TFE lining Stem Seals:Nitrile Stem Retaining Ring:Carbon steel Actuator: • 2-8'/50-200mm: Brass or bronze traveling nut on a steel lead screw, in a ductile iron housing • 10- 12/250-300mm:Steel worm and cast iron quadrant gear, in a cast iron housing www.victaulic.com �Ctaulic VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2010 VICTAULIC COMPANY.ALL RIGHTS RESERVED. REV 1PI.g1 2 IPS CARBON STEEL PIPE- FIRE PROTECTION VALVES I V.a 1 F:ireLock ® Butterfly Valve SERIES 705 WITH WEATHERPROOF ACTUATOR - DIMENSIONS- rr Size Dimensions Inches/millimeters MIME Outside end toy SI"g>> liametet and 2 2.375 4.25 228 6.41 4.00 4.22 4.50 2.12 11 60 3. I .3 3 1:I- 579 162 8 101 6 07.2 114.3 53.8 IligiBil I. 2%" 2.875 3.77 2.28 Z54 4.00 4.22 4.50 1.77 lip, 73 mm 73.095 8 579 91.5 01.6 072 14.345.0 3.000 3.77 579 Z 1. E 4.00 4.22 4.50 77 76.1 mm � 76.1 95.8 579 191.5 101.6 07.2 4.50 45.0 F 3" 3.500 3.77 2.53 7. 4.50 422 4.50 77 G 88.9 mm I 88.9 95.8 64.3 ! 197979 - 114.3 107.2 1143 45.0 I 4.250 4.63 2.88 8.81 5.50 4.22 4.50 2.20 08 mm 108.0 117.6 73.2 223.8 397 107.2 14.3 55.9 w�u� +\ -4" 7 4.500 4.63 2.88 8.81 _ 5.50 4.22 4.50 220 114.3 mm l 114.3 1176 73.2 223.8 139.7 072. 114.3 55.9 i �•� 0H I 5.250 5.88 3.35 0.88 6.56 6.19 6 30 2.58 ��n��r./ 133 mm 133.0 149.4 85.1 276.4 166.6 157.2 160.0 65.5 I 5.500 5.88 3.35 10.88 6.56 6.19 6.30 2.58 1397 494 85.1 2764 666 572 600 656 5" 5563 588 335 1088 656 6.19 630 258 1413mm 1413 149.4 851 2764 1666 1572 600 655 I1397mm 6250 588 384 38 041 752 619 630 258 159 mm 59.0 149.4 97.5 289.1 10.4 191.0 1572 160.0 65.5 I I 3 TJI 6 500 5.88 3.84 11.38 0.41 7.52 6.19 6.30 2.58 E+` ~A D 165.1 mm I 165.1 149.4 975 2891 0.4 91 0 157.2 160.0 65.5 6" 6.625 •5.88 3.84 11.38 0.41 752 6.19 6.30 1.90 Note:Optional i/z"Y15mm tap available. 168.3 I 168.3 149.4 975. 289.1 10.4 191.0 1572 160.0 483 Contact Victaulic for details. 8" 8.625 5.33 5.07 13.53 0.80 147 10.00 6.19 8.10 233 299.1 mm I 219.1 135.4 128.8 343.6 203 373 254.0 1572 205.7 592 10" 10.750 640 6.37 15.64 1.41 1.81 ' 12.25 8.10 9.00 273 mm 1E 273.0 162.6 161.8 397.3 35.8 46.0 311.2 205.7 228.6 12" 12.750 6 50 736 6.64 230 2.80 14.25 8.10 9.00 323.9 mm 323.9 65.1 1869 422.7 58.4 71.1 362..0 205.7 228.6 J www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2010 VICTAULIC COMPANY.ALL RIGHTS RESERVED. �Cta11LlIIC_ RFV C. 10xi3 IPS CARBON STEEL PIPE FIRE PROTECTION VALVES J.V.0 J. c) 8 . FireLoc ® utterfly Valve SERIES 705 WITH WEATHERPROOF ACTUATOR PERFORMANCE The chart expresses the frictional resistance of Victaulic Series 705 Butterfly Valve in equivalent feet/ meters of straight pipe. Size Size Actual - Actual Nominal Outside Nominal Outside Size DiaMeter Equiv. Size Diameter Equiv.47 . dies echo • Feetiei inches Indies Feetim mm mm of Pipe .trim mm of Pipe 2 I 2.375 6 6 6.625 14 50 60.3 1.8 150 168.3 4.2 - I 21/2 2.875 614 159 mm ! 159 mm 4.3 65 73.0 1 8 3.000 6 165.1 mm 6.500 14 76.1 mm 76.1 1.8 165.1 4.2 3 I 3.500 7 8 8.625 16 80 88.9 2.1 200 219.1 4.9 4 4.500 8 10 10.750 18 100 114.3 2.4 250 I 273.0 5.5 8 1212.750 19 108 mm 108 mm 24 300 I 323.9 5.8 5 5.563 12 --1 125 141.3 3.7 12 133 mm 133 mm 3 7 139.7 mm 5.500 12 139.7 3.7 www.victaulic.com \ict.aulic• VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2010 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 10111 4 REV C IPS CARBON STEEL PIPE—FIRE PROTECTION VALVES 1 U.8 A. , ir . .c Butterfly SERIES 705 WITH WEATHERPROOF ACTUATOR PERFORMANCE Cv values for flow of water at+60°F/+16°C with a fully open valve are shown in the table below. For additional details,contact Victaulic. Formulas for Ci,Values: AP = Q2 Where: C z Q=Flow(GPM) AP=Pressure Drop(psi) Q = Cv x 4P C =Flow Coefficient Size cc,C Size Size C� Actual Actual Aatfitl +immal Outsida Nominal Outside - Nominal Outsi le Sizes ammeter Sze Diaaihete(� xk Diall Iter n �, inches illg Inches inches rhes Inches m � mm 1F open) � m 2 (Fut( ppen mak ,mm, (Full open) 2 2.375 70 5 5.563 200 8 8.625 3400 60.3 125 141.3 200 219.1 21/2 2.875 260 133 mm 133 mm 200 10 ' 10.750 5800 65 73.0 250 273.0 76.1 mm ! 3 000 260 39.7 mm i 5.500 200 12 1 12.750 76.1 139.7 300 323.9 9000 80 __.i 3 3.500 440 6 6.625 1800 889 150 1683 4 4.500. 100 114.3 820 159 mm 159 mm 1800 08 mm 108 mm 820 165.1 mm E 6.500 1800 165.1 Formulas for Kv Values: AP = Q2 Where: K 11 Q=Flow lTIT/ Q = K x 4P AP=Pressure(bar) K =Flow Factor Size Kv Size Kv Size Kv Actual Arcual " kcal Nominal outside = nominal 0Autuide xr Nom al Outside maize DiameterDiameter nche aache5` Inehes In hes k y'inches _ inmeter mm mm (Fii Opere, m in ) fFulio#)pen) m mm`' (Full Open) 2 2.375 47 5 5.563 1040 8 j 8.625 2940 60.3 125 41.3 200 219.1 2Yz 2.875 10 10.750 65 73.0 225 133 mm 133 mm 1040 250 273.0 5020 '. 3.000 5.500 12 12.750 76.1 mm 701 225 139.7 mm 1397 1040 300 3239 7790 1 3 I 3.500 380 6 6.625 1560 80 889 150 68 3 4 4.500 100 114.3 710 59 mm_i,,, 159 mm 1560 108 mm 108 mm 710 165.1 mm . 665 1560 J www.victaulic.com VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2010 VICTAULIC COMPANY.ALL RIGHTS RESERVED. jctaulic. 10 RI RFV r. IPS CARBON STEEL PIPE- FIRE PROTECTION VALVES 1 U.0 1 FireLock® Butterfly valve SERIES 705 WITH WEATHERPROOF ACTUATOR SWITCH AND WIRING 1.The supervisory switch contains two single pole,double throw, pre-wired switches. 2.Switches are rated: 10 amps @ 125 or 250 VAC/60 Hz L 0.50 amps @ 125 VDC 0.25 amps @ 250 VDC 3.Switches supervise the valve in the"OPEN"position. 4.One switch has two#18 insulated wires per terminal,which permit complete supervision of leads (refer to diagrams and notes below).The second switch has one#18 insulated wire per termi- nal.This double circuit provides flexibility to operate two electrical devices at separate locations, such as an indicating light and an audible alarm, in the area that the valve is installed. 5.A#14 insulated ground lead (green) is provided. Switch#1=S1 For connection to the supervisory circuit of a UL Listed alarm control panel Switch#2=S2 Auxiliary switch that may be connected to auxiliary devices, per the authority having jurisdiction Normally Closed: (2)Blue S1 Common:(2)Yellow Normally Closed: Blue with Orange Stripe S2 Normally Open: Brown with Orange Stripe Common:Yellow with Orange Stripe LISTED JUNCTION BOX FIRE ALARM TO END-OFLINE RESISTOR, CONTROL PANEL OR NEXT INDICATOR CONDUIT SUPERVISORY CIRCUIT i '..!'411110r f .. NO. COM. �•' , ',� SWITCH _. •� -• CONTACT RATING. _, I IMIE A'NPi 10A AT 125 AND r� I CONDUIT CONNECTORS 250VAC, NM O.SAT125VDC, 025 AT 250VDC Mil NM BELL WIRE NUTS OR Mil MI HORN VOLTAGE TAGE SOURCE Switch 1:2 leads per terminal Switch 2:1 lead per terminal NOTE:The above diagram shows a connection between the common terminal (yellow-S1 and yellow-with-orange stripe-S2)and the normally closed terminal (blue-S1 and blue-with-orange stripe-S2). In this example,the indicator light and alarm will stay on until the valve is fully open. When the valve is fully open,the indicator light and alarm will go out.Cap off any unused wires (e.g. brown with orange stripe). Only S1 (two leads per terminal)may be connected to the fire alarm control panel. The connection of the alarm switch wiring shall be in accordance with NFPA 72 and the auxiliary switch per NFPA 70(NEC). www.victaulic.com \iCtaulic VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2010 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 10 R1 6 REV C P 13i30 TkcT FireLock® Butterfly Valve SERIES 705 WITH WEATHERPROOF ACTUATOR WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. INSTALLATION Reference should always be made to the installation sheet included with the valve.Verify you have the latest revision by visiting our website at www.victaulic.com. Further reference can be found in the 1-100 Victaulic Field Installation Handbook. For complete contact information,visit www.victaulic.com 10.81 5662 REV C UPDATED 12/2010 ,Ctaull(: VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2010 VICTAULIC COMPANY.ALL RIGHTS RESERVED. V� lo.Rn s ,: Ire o ® Check Valves c . us 1 (vds) LPCB SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS SERIES 717—cULus, FM,VdS, LPCB SERIES 717H HIGH PRESSURE—cULus, FM,VdS, LPCB ._ .... .- The FireLock Series 717 Check Valve and Series 717H High Pressure Check Valves are CAD- ViAle. —‘4-- designed for hydrodynamic efficiency and available in 2"/50mm—3"/80mm(Series 717H)and 21/2"/65mm—12"/300mm(Series 717)sizes. Series 717H valves are cULus Listed and FM Approved for service up to 365 psi/2517 kPa.See •r chart below for approved services for the Series 717 valves. In both valve designs,the single-disc mechanism incorporates a spring-assisted feature for non- Series 717 slamming operation.This spring-assisted,single-disc design achieves a leak-free seal with as (2' —3165—80mm) little as 5ft/1.5m of head.Series 717 and 717H FireLock Check Valves can be installed either .•'•'•'•••l•I•'""""" 0. vertically(flow upwards only)or horizontally.A cast flow arrow indicator is provided to assist with - 1 ■ Vic : ■ proper valve orientation. Both valves include upstream and downstream pressure taps.Each . valve is factory-tested to the rated working pressure. For systems requiring a Riser Check option, ■ refer to publication 10.09. ■ "^' ■ Grooved ends allow fast,easy installation with just two Victaulic couplings or the valve may be ■ ■ mounted to flanged(ANSI CL.150)equipment using either to Victaulic Style 741 Vic-Flange®or ■ Style 744 FireLock flange adapters on either end. ■ ■ x ■ U ■ Series 717 ■ (4—121100—300mm) . i. Approval/Listing Service Pressuresc ' PON Series 717H Size cULus FM LPCB Vds 2750 mm up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa 21/2"/65 mm up to 365ps1/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa 76.1 mm up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa Series 717H High Pressure Check Valve 3/80mm up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa (2—3150—80 mm) 47100 mm r/an/a n/a n/a 5'/125mm n/a n/a n/a n/a 139.7mm n/a n/an/a n/a 67150 mm Na n/a n/a n/a 165.1 mm n/a n/a n/a r✓a 87200 mm n/a n/a n/a n/a 107250 mm n/a n/a n/a n/a 127300mm n/a n/a n/a n/a Approval/Listing Service Pressures Series 717 .k^5"'F`h FM'.r i VdS `` z Size ',���'. cULus k„ %s,`� .�w�" 'rim ,"; .,#f�.'8...... i ;; 2750mm n/a n/a n/a n/a 21/'/65 mm up to 250 psi/1725 kPa n/a up to 365 psi/2517 kPa n/a 76.1 mm up to 250 psV1725 kPa n/a up to 365 psi/2517 kPa up to 16bar/232 psi 3780 mm up to 250 psV1725 kPa n/a up to 365 psi/2517 kPa up to l6bar/232 psi 47100 mm up to 365 psV2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 16bar/232 psi 57125 mm up to 365 psV2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa n/a 139.7 mm up to 365 psV2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 16bar/232 psi 67150 mm up to 365 psV2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 16bar/232 psi 165.1 mm up to 365 psV2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa n/a 87200 mm up to 365 psV2517 kPa up to 365 psi/2517 kPa up to 348 psi/2400 kPa up to 16bar/232 psi 10"/250 mm up to 250 psV1725 kPa . up to 250 psi/1725 kPa up to 1725 kPa/250 psi n/a 127300 mm up to 250.sV1725 kPa up to 250 psi/1725 kPa up to 1725 kPa/250 psi n/a JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved v Date WWW.VICTAULIC.COM CtaUIiIC VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2011 VICTAULIC COMPANY.ALL RIGHTS RESERVED. REV P - 10 CIA I IPS CARBON STEEL PIPE - FIRE PROTECTION VALVES 1 V.va y ' Lock() Check Valves SERIES 717-cULus, FM,VdS, LPCB SERIES 717H HIGH PRESSURE-cULus, FM,VdS, LPCB DIMENSIONS-Series 717 A B 1 t Size Approx Dimensions Inches/millimeters Wgt.Ea the �� �AcWal � - 0 *nal Olaurniseidele sizes 0 C 1n+Ates E W£ s r Lbs --'� gym " m ,A 6 C ;. , C " l TYPICAL 21-3"/65-80 MM 2%z 2.875 3.88 4.26 3.57 3.6 s, 65 73.0 99 108 91 1.6 76.1 mm 3.000 3.88 4.26 3.57 _ 3.6 R A t 76.1 99 08 91 1.6 1 3 3.500 4.25 5.06 4.17 4.5 80 88.9 108 129 106 - 20 IJI��III�_� 4 4.500 9.63 6. 3.88 2.75 3.50 2.00 4.50 3.50 3 35 20.0 �I III III D 00 114.3 245 99 70 860811966077 9 51 114 89 85 9.1 �� I •- 5 5.563 10.50 6. 4.50 4.17 2.15 5.88 4.08 3.98 27.0 B� I O 125 141.3 267 1:5880332000 114 106 55 149 104 1011 123 /K"NPT U stream D©in 139.7 mm 5.500 10.50 6. 4.50 4.17 2.15 5.88 i 408 3.98 27.0 1 p 39.7 267 114 06 55 149 104 01 12.3 O Y'NPT Downstream Drain 6 6.625 11.50 8.00 5.00 _ 4.50 2.38 667 473 3.89 38.0 0 2"NPT(Drain Optional) 50 168.3 292 203 127 114 61 169 '200700044388 0 99 172 TYPICAL 4-8"/100-200 MM 65.1 mm ( 6.500 1.50 8.00 5.00 4.50 2.38 6.67 4.73 3.89 38.0 165.1 292 203 127 114 61 169 ° 120 99 17.2 8 8.625 14.00 9.88 6.1.1:5j: 5.05 5.65 2.15 8.85 5.65 5 75 64.0 41"1. r i sl 200 219.1 356 251 28 144 55 225 44 46 29.0 1411) III /� I 4 10 10.750 700 12.00 7.09 5.96 6.69 2.15 10.92 6.73 100.0 250 --1 273 0 432 305 180 151 170 55 277 171 45.4 II� " I 12 � 12.750 19.50 j 14.00 8.06 6.91 764 2.51 2.81 773 140.0 I\I II - E 300 I 323.9 495 356 205 176 94 64 925 196 63.5 lc 1,-K-�I '4 i p -B -9-3 0' 'NPT Upstream Drain 0 Y"NPT Downstream Drain TYPICAL 10-12"/250-300 MM DIMENSIONS-Series 717H Size Approx. Dimensions Inches/millimeters tionlinat Wgt Ea. A '4 IIII iir ! i C G1 2 8.66 • 6.46 3.23 48 3.02 2.80 4.25 10.7 11110.017- �, �� 11111 E \\ // 60.3 219.8 164.1 821 37.5 76.7 71.0 1.1r 108.0 49 �� �� 2Yz 9.37 6.94 3.31 1.66 3.40 3.38 4.38 13.8 �R 73 238.0 176.3 84.1 42.2 86.4 . 85.9 111.3 6.3 76.1 mm 937 6.94 331 66 3.40 3.38 4.38 3.8 238.0 76.3 84.1 42.2 86.4 85.9 - 11.3 6.3 TYPICAL 2"/60.3 mm-3"/88.9 mm 3 -1 9.62 744 3.53 1.91 3.65 3.38 _ 4.63 20.0 88.9 244.3 189.0 897 48.5 92.7 85.9 17.6 9.1 • www.victaulic.com VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2011 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ✓c'taUllc 1CIORR 2 REV P IPS CARBON STEEL PIPE- FIRE PROTECTION VALVES 1 V.Ua FireLock° Check Valves SERIES 717—cULus, FM,VdS, LPCB SERIES 717H HIGH PRESSURE—cULus, FM,VdS, LPCB MATERIAL SPECIFICATIONS Body: Ductile Iron conforming to ASTM A-536,grade 65-45-12. Ductile iron conforming to ASTM - A-395,grade 65-45-15, is available upon special request. Body Coating:Series 717H Body: Black Paint Series 717H Endface: Electroless Nickel Series 717(21 —3"): PPS Coating Series 717 (4—12"): Black Paint Body Seat:Series 717H—Nitrile 0-ring installed into an electroless nickel plated endface Series 717 (21/2—3"): PPS Coated ductile iron Series 717 (4—12"):Welded Nickel Disc Seal or Coating: • Grade"T"Nitrile(Series 717H ONLY) Nitrile(Orange color code).Temperature range—20°F to+180°F/-29°C to+82°C. Recommended for petroleum products,air with oil vapors,vegetable and mineral oils within the specified temperature range;except hot,dry air over+140°F/+60°C and water over+150°F/+66°C. NOT RECOMMENDED FOR HOT WATER SERVICES. • Grade"E" EPDM(Series 717 ONLY) EPDM (green color code).Temperature range-30°F to+230°F/-34°C to+110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. NOT RECOMMENDED FOR PETROLUEM SERVICES. * Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Discs: • Series 717H (2—3150—80 mm): CF8M Cast Stainless Steel • Series 717(21 —3"):Aluminum bronze with elastomer seal • Series 717(4—12'/100—300 mm) Elastomer-coated ductile iron Shaft: • Series 717H (2—3150-80mm): Brass • Series 717(21/2—3"):Type 416 Stainless Steel • Series 717(4—12'/100—300 mm)Type 316 Stainless Steel Spring:All sizes Type 302/403 Stainless Steel Shaft Plug: • Series 717H (2—3'/50—80 mm):Type 416 Stainless Steel • Series 717(21/2—12'/65—300 mm):Carbon steel zinc plated Pipe Plug: • Series 717H (2—3'/50—80 mm):carbon steel zinc plated • Series 717 (4—12'/100—300 mm):Carbon steel zinc plated www.victaulic.com �Ctaulic. VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2011 VICTAULIC COMPANY.ALL RIGHTS RESERVED. OR 71 RFV P IPS CARBON STEEL PIPE - FIRE PROTECTION VALVES1 V.V8 m _ r .Loc: SERIES 717-cULus, FM,VdS, LPCB SERIES 717H HIGH PRESSURE-cULus, FM,VdS, LPCB - FLOW CHARACTERISTICS 1.:6,. & ti� 3 The charts below express the flow of water at 60°F/16°C through valve. S717H/717HR 10 vi Y a v. O 1 ��� ��F o�� LLJ �$ CCVI w C a 0.1 10 100 FLOW RATE-G.P.M. ILI CC S717H/717HR yon ° �o� 100.00 a H V/ 10.00 �� F H w C a 1.00 100 1000 FLOW RATE(Litres/Min) 1000 10000 www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2011 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ✓ctalulic° 10 OR 4 REV P IPS CARBON STEEL PIPE - FIRE PROTECTION VALVES 1U.U0 r FireLock® Check Valves SERIES 717—cULus, FM,VdS, LPCB SERIES 717H HIGH PRESSURE—cULus, FM,VdS, LPCB FLOW CHARACTERISTICS The charts below express the flow of water at 60°F/16°C through valve. 5717/717R 10 F AL Al O: �c� F F F o��6� til cer (12 ti ti N 0, 3 O Qr A vi 4r 4' o H 1 �� h. p. v� �ti� ut 1 ccH / W a 0010Alio /� 0.1 10 100 1000 10000 100000 FLOW RATE-G.P.M. 5717/717R 100.00 To. O. F F F F F F F vi ^(F , of , hF o� n`s ooF I 10.001/4Y 4r v vv W N r) a 4 47 S titi cc D viH W cca 1.00 10.00 100 1000 10000 100000 FLOW RATE(Litres/Min) www.victaulic.com ictaulic VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2011 VICTAULIC COMPANY.ALL RIGHTS RESERVED. '"'"" irl_OR 5 RFV F' FireLocke Check Valves SERIES 717—cULus, FM,VdS, LPCB SERIES 717H HIGH PRESSURE—cULus, FM,VdS, LPCB INSTALLATION Series 717 and Series 717H Check Valves can be installed either vertically(flow up only)or horizontally (with hinge on top)-making sure the flow arrow matches the flow direction through the pipeline. Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing.Handbooks are included with each shipment of Victaulic products for complete installation and assembly data,and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. For complete contact information,visit www.victaulic.com 10.08 1479 REV P UPDATED 6/2011 VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2011 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ictaUlllc' 10.08 o,P ,T ,meq s ,,::wt,. *, ..., �'': „ .:: cOus ® LPCB vds FireLock® SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS SERIES 728 IIIMINIIIIIIIBIIIIIMINIMIMMINII■ The Series 728 FireLock valve is a full port,ball valve that is UUFM rated for 0 ■ 41 31 '` ■ 365psi/25 BAR service in all sizes(LPCB and VdS listed for 20 BAR services). Available with grooved or threaded ends(NPT),the valve body is brass.The ball is a chrome plated brass with a stainless steel stem.Reinforced seats aid ease of _ - , operation and provide a durable,corrosion-free seat. Flow characteristics exceed UL Specification 1091 and FM Approval Standard 1112.The valve is approved for °"� ,, ■ indoor and outdoor use. I ■ ■ �. ■ _ I ■ MI I dMI■I■I.I.I.I■I.I.I■I.r DIMENSIONS Approx. H Size Dimensions Inches/mm Wgt Each -.1,1_, G 7 iii/ 3 K ■i I, ' 1iominat : E o E Height � 1c B iii.r.ll�i l 4 Iiiimmi Inches/um A 8� D ,, 7 2.84 4.74 0.91 1.67 1.82 2.40 3.15 4.86 0.68 1.42 3.00 5.1 ._ F ��� e 1/25 Thd.X Thd. II i� ° 72 120 23 42 46 61 80 123 17 36 76 2.3 �) .I si ' 1'/a/32 Thd.X Thd 3.31 4.95 1.10 1888 2.20 2.61 3.15 4.86 0.68 1.65 3.00 5.8 'I ii'I' i 84 26 28 48 56 66 80 23 17 42 76 26 E 36625 5.13 1.29 2.06 2.58 2.79 3.15 4.86 0.68 1.83 3;360 6.6 A h/40 Thd.X Thd. 130 33 52 66 71 80 123 17 47 3 0 GROOVED X GROOVED 2/50 Thd:XThd. 4.33 549 1.69 2.42 3368 : 3.15 3.15 4.86 068 2.16 3;06(,) 8.5 H 110 40 43 62 80 80 123 7 55 3.9 1 G--.1 a/32 Grv.X Grv., 7.25 4.95 1.10 1.87 2.20 2.61 3.15 4.86 0.68 3.19 3.00 7.5 184 126 28 48 56 66 80 123 17 81 76 3.4 jI� iii 7- -1.' --..L 7.25 5.17 1.29 2.10 2.58 2.83 3.15 4.86 0.68 3.19 3.00 8.5 _/ �, \ K i�) " 1/x/40 Grv.X Grv.* 184 131 33 53 66 72 80 123 17 81 76 3.9 la 11)31�! ;:°'III�N�III _.. 1 1,1 a 7.25 5.47 1.69 2.40 3.38 3.13 80 4.86 0.68 3.19 3.00 10.5 ��. 2/50 Grv.XGrv.* 184 139 43 61 86 80 80 123 17 81 76 4.8 i• i ` ' F f 0_��1111V.q i D ' 'Ph and 2"/40 and 50mm sizes feature a' '/12mm tap(Groove by Groove only). t-.t4 j E THREADED X THREADED PERFORMANCE SIZE Equivalent SIZE Equivalent Nominal Inches/mm Feet/meters of Pipe Nominal Inches/mm Feet/meters of Pipe 0.7 1/25 Thread X Thread 0.5. 1 Ya/32 Groove X Groove 0.2 1.00.7 1'//40 Groove X Groove 11/4/32 Thread X Thread 0.3 3 0.2 X Groove 0.7 11/2/40 Thread X Thread 1.0 3 2/50 Groove0.2 2/50 Thread X Thread 1.0 0.3 JOB/OWNER CONTRACTOR ENGINEER _ System No. Submitted By Spec Sect Para Location Date Approved _ Date www.victaulic.com \iCtauIic VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2011 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 10.17 1 REV H IPS CARBON STEEL PIPE-FIRE PROTECTION VALVES 1 U. I / it . B an Valve SERIES 728 - SWITCH AND WIRING 1.The supervisory switch contains two single pole,double throw,pre-wired switches. 2.Switches are rated: 10 amps @ 125 or 250 VAC/60 Hz 0.50 amps @ 125 VDC 0.25 amps @ 250 VDC 3.Switches supervise the valve in the"OPEN"position. 4.One switch has two#18 insulated wires per terminal,which permit complete supervision of leads (refer to diagrams and notes below).The second switch has one#18 insulated wire per terminal. This double circuit provides flexibility to operate two electrical devices at separate locations,such as an indicating light and an audible alarm,in the area that the valve is installed. 5.A#14 insulated ground lead(green)is provided. Switch#1=S1 For connection to the supervisory circuit of a UL Listed alarm control panel Switch#2=S2 Auxiliary switch that may be connected to auxiliary devices,per the authority having jurisdiction Normally Closed:(2)Blue S1 Common:(2)Yellow Normally Closed: Blue with Orange Stripe S2 Normally Open: Brown with Orange Stripe Common:Yellow with Orange Stripe UL[GILD JUNCTION BOX FIRE ALARMPAN TO END-OF-LINE RESISTOR, CONTROL PANEL OR NEXT INDICATOR CONDUCT , SUPERVISORY CIRCUIT r ��il �- 1��� NO. COM. h'NPT `•�' CONTACT RATING: WI _ ® CONDUITCONNECTORS , 10A A50AC, 0125, O SA AT 125 VDC, __ 0 25 AT 250 VDC WIRE NUTS BEELRL VOLTAGE SOURCE HORN Switch 1:2 leads per terminal Switch 2:1 lead per terminal NOTE:The above diagram shows a connection between the common terminal(yellow-S1 and yellow- with-orange stripe-S2)and the normally closed terminal(blue-S1 and blue-with-orange stripe-S2). In this example,the indicator light and alarm will stay on until the valve is fully open.When the valve is fully open,the indicator light and alarm will go out.Cap off any unused wires(e.g.brown with orange stripe). Only S1(two leads per terminal)may be connected to the fire alarm control panel. The connection of the alarm switch wiring shall be in accordance with NFPA 72 and the auxiliary switch per NFPA 70(NEC). MATERIAL SPECIFICATIONS Valve Body: Brass ASTM B124 Ball: Chrome Plated Brass Ball Valve Stem:316 Stainless Steel Seat: Carbon Filled (TFE)tetrafluoroethylene Stem Nut: Brass ASTM B-16 C36000 Actuator: Brass traveling nut,on a steel lead screw, in a ductile iron housing www.victaulic.com VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2011 VICTAULIC COMPANY.ALL RIGHTS RESERVED. jCtaUiiCa 10.17 2 REV H • • FireLock° Valve SERIES 728 INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you - are installing.Handbooks are included with each shipment of Victaulic products for complete installation and assembly data,and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. For complete contact information,visit www.victaulic.com 10.17 2226 REV H UPDATED 05/2011 Irtcal✓fliC VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2011 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 10.17 I FIS ?RC/DUCTS :.. Fired ® Zone Control Riser Module ® E) SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS SERIES 747M Designed for NFPA 13 commercial requirements,the Victaulic Series 747M Zone Control Riser Module features a cast body,and is compact and easy to install in zoned wet sprinkler systems. ,` - The integrated module body consists of a shut off valve,test and drain valve combination and different orifice sizes(K factors),a UL Listed and FM Approved Flow Switch,and a Pressure • Gauge.The Series 747M FireLock Zone Control Riser Module is available in sizes from 11/2 through 6"/32mm- 150mm with grooved ends on the main pipe for installation in the horizontal or vertical up-flow positions with UL Listed, FM Approved Victaulic grooved couplings. 1 / -2"modules have an NPT drain port.2 / 6"modules have a grooved drain port. The Series 747M FireLock Zone Control Riser Module is FM Approved and UL and ULC Listed for working pressures up to 365psi/2517 kPa.An optional pressure relief valve kit is available STYLE 747M for all sizes.The Pressure Relief Valve is FM Approved and UL and ULC Listed for working PATENT PENDING pressures up to 175psi/1200kPa. ......■..............■.■.■...■.■. ■ -_ ._..__.. ._. --.__.. _____._ _.. ____ - ______ _. ..._.. ._...__........ _. _.._-. __ _ .----._____ _______ ._.__.__. ■ ▪ DIMENSIONS ■ Module Body Size. Dimensions Inches/mm Aprx Weight ' I=. i ■ - :, Each } � } aka ' ■ a. � 7 �a 4 �) etIftg U s '� 1 's° ' ■ 3 e r. , 1.660 ,,., ^,,,' . X,- �1 f a y is �,1"� ;. no-F.. 024.44. T- 11.45 7.20 5.77 3.50 10.05 7.48 2.54 15.2 ' D "i a ':.i% , 1 I 32 42.2 33.4 290.8 182.9 146.5 88.9 255.3 190.0 64.5 6.9 ■ i 11,,.... :---311/1 C 11 1.900 1 11.45 7.32 5.77 3.50 10.05 7.48 2.54 15.5 l . 40 48.3 33.4 290.8 185.9 146.5 88.9 255.3 190.0 64.5 7.0 + I 2 2.375 1 11.45 7.55 5 77 3.50 10.05 7.48 2.54 19.9 ■ , ;. - -- I 50 60.3 33.4 290.8 191.8 146.5 88.9 255 3 190 0 64.5 9.0 ■ E G ■ 2' 2.875 1 '/4 12.00 8.41 6.18 4.25 9.76 11.87 4.25 22.7 65 73.0 , 42 305 214 157 108 248 302 108 10.3 ■ I A 3 3.500 1 1/4 12.00 9.42 6.18 4.25 9.76 11.87 4.25 23.2 I '-'.'.''1+1.i 1"P32,5b Alai RotnIfiA Slier''1"'•'_'■ 80 88.9 42 305 239 157 108 248 302 108 10.6 4 4.500 2 12.00 9.90 7.25 5.00 10.15 12.62 4.21 30.3 ® I100 114.3 60 305 252 184 127 258 321 107 13.8 '41.�i ._.. _..... __. ... __.. 6 6.625 2 12.00 10.85 8.31 6.00 10.15 13.62 4.24 36.7 B 150 168.3 60 305 276 211 154 258 346 107.7 16.7 1t n li ' li Div;55,4„, 1 Onfices iFir � 4�I ` G 1 C 1.25 K5.6 r12447:17 ; 1.5 K5.6 F rr„',o2 K5.6 Cr 2.5 K5.6 K6.9 K8.0 K11,2 E i i 3 K5.6 K6.9 K8.0 K11.2 I 4 K5.6 K6.9 K8.0 K11.2 K14.0 K16.8 6 K5.6 K6.9 K8.0 K11.2 K14.0 K16.8 A --.- 21/2-6765.0-150 mm Nominal Sizes (Valves shown above in the"test"position. Nominal Size Drain Type Drain Size Shown with optional Pressure Relief Valve Kit nches installed) 1.25 NPT 1" Hose Clamp 1.5 NPT 1" 2 NPT, 2.5 Grooved 4 1%4" 1" Pressure Relief Valve 3 Grooved Barbed Fitting 4 Grooved 2 Hose Clamp ~-DrainTubin 6 Grooved 2' Close Nipple 9 Elbow Barbed Fitting Optional Pressure Relief Valve Kit Detail JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved - Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2010 VICTAULIC COMPANY.ALL RIGHTS RESERVED. jctaulic'--- RFV I 10c16 1 FireLock® o s , Module SERIES 747M MATERIAL SPECIFICATIONS Module Body:Cast from ductile iron conforming to ASTM A-536,grade 65-45-12 with integral Victaulic grooved ends. Finish:orange enamel. Shut-off and Test/Drain Valve:Chrome plated brass ball,S 37700 brass clapper,416SS or 410SS shafts, Delrin orifice,virgin Teflon*,enhanced Teflon and EPDM rubber seals. *Teflon is a registered trademark of Dupont Coupling:Any UL Listed, FM Approved Victaulic IPS-sized coupling may also be used. Note: Couplings not included with product. Waterflow Detector:System Sensor Model WFD/WFDTH vane type waterflow detector with sealed retard,visual switch activation,and mechanical delay adjustment.Cover includes tamper resistant security screws and tool. Note: ULC models WFDA/WFDTHA include cover tamper switch. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. WARNINGx p Y • This product must be installed by an experienced,trained installer, in accordance with the instructions provided with each valve.These instructions contain important information. c Failure to follow these instructions may result in serious personal injury, - , property damage,or valve leakage. If you need additional copies of this product literature or the valve installation instructions,or if you have any questions about the safe installation and use of this device,contact Victaulic Company, P.O. Box 31, Easton, PA 18044-0031 USA,Telephone:001-610-559-3300. For complete contact information,visit www.victaulic.com 10.96 3089 REV I UPDATED 7/2010 •CtaUlic VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2010 VICTAULIC COMPANY.ALL RIGHTS RESERVED. If)9 Angle Hose Valves UL, ULC and FM Approved F P P ' Description Angle hose valves feature all brass*construction with forged or cast bodies �� for rigidity and light weight. Typical uses are in rack assemblies or any other application which requires a listed fire hose valve.Available in rough brass or polished chrome finish with a red hand wheel. UL, ULC and FM Approved. ` Rated 300psi . " � �� . ,. , ortte m Y l Installation Install in accordance with customary installation practices. Use an approved Specifications thread sealant such as PipeFit Thread Sealing Paste with PTFE on the male Body Material: s threads to which the valve is being installed. Cast or Forged Brass' I Finish: DO NOT OVER TIGHTEN. Over tightening of the valve during installation Rough Brass to the male pipe threads may crack or deform the valve body. Only use Polished Chrome* tools suitable for the installation of this product. Do not use pipe wrench Threads: extenders to increase leverage on , " g pipe wrenches.This may result in valve 2/z FNPT x FNPT r damage as well as personal injury. FNPT x MNST* MBCT MAST MONT MPHX MTEM x MCLV Z1/2"GRV x FNPT GRV x MNST 11/2"FNPT x FNPT FNPT x MNST i Friction loss is less than 3 psi thru an equivalent length of pipe per UL Standards. *Contains lead.Not for use in water systems intended for human consumption. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL+1 800 344-1822 �L FM © FAX+1 800 344-3775 c • ©2012 Fire Protection Products,Inc. LISTED LISTED APPROVED fTllII. 91 . IT , , SprinklerS are Headp Storage Cabinet Description Fire Protection Products, Inc. Spare Sprinkler Head Cabinets are designed to allow for spare sprinkler head storage as required by NFPA guidelines. The Spare Sprinkler Head Cabinets are available Specifications in six configurations. Three head, six head, six head ESFR, twelve Material: Ma head, twenty-four head and thirty-six head. All six styles are Paintedl: plain steel manufactured with "knockouts" to accommodate the most common size sprinklers. The shelf is located to allow for the storage of a Finish: typical sprinkler head wrench. Each cabinet is finished with a red Red enamel enamel fi nish. Each spare head cabinet comes with a hinged door which remains closed to protect the spare sprinklers from the Styles: elements and features two holes on the back panel to allow for 3 Spare sprinklers, attachment to most surfaces utilizing the appropriate fasteners. 1/2 or 3/4 Not intended for exposed or harsh environments. 6 Spare sprinklers, 1/2 or 3/4 6 Spare, ESFR, Installation1/2 3/4 or 1" , Select the correct Spare Once the correct Spare Sprinkler I Sprinkler Head Cabinet in Head Cabinet has been select- 12 Spare sprinklers ._ or 3/4; /2 accordance with the Automatic ed, installation is accomplished ...... ,,......,..- 1 Sprinkler Systems Handbook. by inserting the correct fastener 24 Spare sprinklers As per the 1989 Edition the in each of the two holes inside 36 Spare sprinklers correct number of spare the cabinet, securing the cabinet sprinkler is as follows: securely to the wall. The insert the correct number and type of "0-300 sprinklers, not less than 6 sprinklers in accordance with the 300-1000, not less than 12 "handbook". 1000 or more, not less than 24. *Final determination is subject to approval Stock of spare sprinklers shall by the AHJ. include all types and ratings installed."* l „% • '%%' Fire Protection Products, Inc v 6241 Yarrow Dr.,Suite A,Carlsbad,CA 92011-1541 ©2000-2007 Fire Protection Products,Inc(FPPI) F.,•P,.P.i! For questions: 1 800 344-1822• 1 800 344-3775 fax•www.fppi.com F.: Q � . � ��GT D4�TR$ "x mak; d, V38 K5 6 ® Az. 0 @P ILPCBJ (ECD Adjustable Concealed Standard Spray Pendent Standard and Quick Response SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS V3801 STANDARD RESPONSE V3802 QUICK RESPONSEOft - This concealed,designer style sprinkler allows up to' 713 mm adjustment to accommodate concealment needs. The "standard"design provides a consistent hemispherical spray pattern. The separate two-piece mounting cup/cover plate allows easy installation and testing prior to ceiling installation. It also permits removal of suspended ceiling panels without system shut- down. The design incorporates state-of-the-art, heat responsive,frangible glass bulb design ter (standard or quick response)for prompt, precise operation. This sprinkler is available in various temperature ratings(see chart on page 2)and finishes to V3801 AND V3802 meet many design requirements. SPRINKLER OPERATION: The operating mechanism is a frangible glass bulb which contains a heat responsive liquid. During a fire,the ambient temperature rises causing the liquid in the bulb to expand.When the ambient temperature reaches the rated temperature of the sprinkler,the bulb shatters.As a result,the water- way is cleared of all sealing parts and water is discharged towards the deflector. The deflector is designed to distribute the water in a pattern that is most effective in controlling the fire. CO VERAGE: — _ .__ __ For coverage area and sprinkler placement, refer to NFPA 13 standards. TECHNICAL SPECIFICATIONS: Models:V3801, V3802 _____---"- ACCESSORIES Style:Adjustable concealed,ordinary hazard, Installation Wrench: (1.\i,i;j� light hazard • Concealed: V38-4 or V38-5 Nominal Orifice Size: � /13 mm Sprinkler Finishes: jK-Factor:5.6lmp./8.1 Imp./8.1S.1.^ ��� 1 Plain Brass(only) , Nominal Thread Size: '/15mm Cover Finishes: 4Looio..00.00. � 11i''�(� �/ Max. Working Pressure: 175 psi/1200kPa • Chrome Plated ,�j13 Factory Hydrostatic Test: 100% @ 5 foal , 00 psi/ White Painted 3450kPa • Flat Black 11' Min. Operating Pressure: 7psi/48kPa Tem era Custom Painted . flik I� % Temperature Rating:See chart on page 2. • MATERIAL SPECIFICATIONS ^ For K-Factor when pressure is measured in ® Deflector: Bronze per UNS C22000 Bar, multiply S.I. units by 10.0. i 0 1 Cover Plate: Fusible solder Teflon is a registered trademark of Dupont Co. /� Bulb:Glass with glycerin solution. 0 Bulb Nominal Diameter: ® • Standard:5,0 mm • Quick Response:3,0 mm � ; _ Load Screw: Bronze per UNS C65100 Pip Cap: Bronze per UNS C65100 Exaggerated for clarity Spring:Stainless steel per UNS S30100 Seal: Teflon*tape Frame: Die cast brass 65-30 Pins:Stainless steel per UNS S30400 Cup:Cold rolled steel,zinc chrome plated Cover/Escutcheon: Brass per UNS C26000 Lodgement Spring:Stainless steel per UNS S30200 Protective Cap: Polyethylene JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Location Spec Sect Para _ Date Approved Date www.victaulic.com VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2013 VICTAULIC COMPANY.ALL RIGHTS RESERVED. REV N �Ctau�iC® 40.50 1 FIRE PROTECTION PRODUCTS--AUTOMATIC SPRINKLERS 4V. V ::.t Adjustable Concealed Standard Spray Pendent Standard and Quick Response V3801 STANDARD RESPONSE V3802 QUICK RESPONSE Model APPROVALS/LISTINGS 1 v382 y,' Orifice Size(inches)Kh'.... _ 13 13 Orifice Size(mm) ..,Sb _ 5.6 Nominal K Fa ctor Imperial 8.1 8.1 Nominal K Factor S.1^ Standard Quick# 3mm bulb Response 5mm bulb Concealed Concealed Pendent Deflector Type Pendent Adjustment Approved Temperature Ratings FIC'by Agency 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 175°F/79°C 1750F/79°C UL 200°F/93°C 200°F/93°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 175°F/79°C 200°F/99 3°C ULC 105°F/ °C 200°F/93°C 155°F/68°C# 175.F/79°C# FM# 200°F/93°C# 135°F/57°C 135°F/57°C 135°F/57°C 1550F/680C 175°F/79°C NYC/MEA#62-99-E 175°F/79°C 200°F/93°C 200°F/93°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 175°F/79°C 2 CSFM#7690-0531:112 05°F/ °C 200°F/93°C 200°F/99 3°C 155°F/68°C Sprinkler/138°F/59°C Cover 1557/68°C Sprinkler/1387/59°C Cover 175°F/79°C Sprinkler/1657/74°C Cover LPCB 175°F/79°C Sprinkler/165°F/74°C Cover 200°F/93°C Sprinkler/1657/74°C Cover 200°F/93°C Sprinkler/165°F/74°C Cover 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 175°F/79°C VNIIPO 175°F/79°C 2000F/930C 2000°F/993°C 286°F/141°C 286°F/141°C ZSTDY NONE CCCf 155°F/68°C #Recognized by FM as standard response only t Listings and Approvals as of printing.All are approved open,except for areas designated"No". ^For K Factor when pressure is measured in Bar,multiply S.I.units by 10.0 www.victaulic.com \iCtauli VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2013 VICTAULIC COMPANY.ALL RIGHTS RESERVED. EV N 4(}.5Q 2 FIRE PROTECTION PRODUCTS- AUTOMATIC SPRINKLERS 4U.0t) ° 6 Adjustable Concealed Standard Spray Pendent Standard and Quick Response V3801 STANDARD RESPONSE V3802 QUICK RESPONSE - RATINGS All glass bulbs are rated for temperatures from-67°F/-55°C to those shown in table below. Sprinkler Sprinkler-V3801,V3802 Cover-V38 Temperature -°PC s Temperature-°J C Maximum Vicfaulic Nominal Ambient yi aufis Nominal Ambient Temperature Part Temperature Te er ture Wass BulbarkTempeatte T per Lu e1aassification Identification Ratingsowed Color identification Rating 7" dowel{ Ordinary A 35 100 57 38 Orange q* 35(d 100 ®_..._.__ 57 38 Ordinary C 155 100 Red D# 165 150 68 38 74 65 Intermediate i E 175 150 79 65 Yellow intermediate F 200 150 93 65 Green *A For use with Standard or Quick Response Concealed Sprinkler 135°F/57°C or 155°F/68°C. #D For use with Standard or Quick Response Concealed Sprinkler 175°F/79°C or 200°F/93°C. Custom Finish—Customer to provide paint specification,allow 4-6 weeks for samples, 0 138°F/59°C per LPBC • ORDERING INFORMATION Please specify the following when ordering: Sprinkler Model Number Style Temperature Rating y K-Factor Thread Size Quantity Cover Finish Wrench Model Number WARNING • • Proper temperature rated cover must be used with the correct sprinkler rating per the Temperature Chart Ratings. • The plastic shipping cap must be removed for the sprinkler to operate properly. • If shipping cap is replaced over an installed sprinkler for purposes of painting or plaster- ing,then the fire protection system shall be considered out of service,the Authority Having Jurisdiction notified,and a firewatch is suggested. Failure to do so may result in failure of sprinkler to operate causing serious personal injury or property damage. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2013 VICTAULIC COMPANY.ALL RIGHTS RESERVED. RFV N 40.50 3 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS 4V. V , V38, Adjustable Concealed Standard Spray Pendent Standard and Quick Response V3801 STANDARD RESPONSE V3802 QUICK RESPONSE WARNING4,0, ,_,.,_ , ,, ... NI„,,,,,,or.,„,,.,, „ , .v ,,,.,,,,l'''' ''.'"r.ex, • Always read and understand installation,care,and maintenance instructions,supplied with each box of sprinklers, before proceeding with installation of any sprinklers. c • Always wear safety glasses and foot protection. • Depressurize and drain the piping system before attempting to install, remove,or adjust any Victaulic piping products. Ir. � • Installation rules,especially those governing obstruction, must be strictly followed. • Painting, plating,or any re-coating of sprinklers(other than that sup- 0 pliVictaulic)is not allowed. could result in serious Failureed to follow these instructions personal injury and/orby property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the current National Fire Protection Ationalssociation pamaintenancmphlet, that d,escribesand care and maintenance of sprinkler _ systems. In additione ,testingthe authority having jurisdiction may have addi- inspection requirements that must be followed. If you need additional copies of this publication,or if you have any questions about the safe installation of this product,contact Victaulic World Headquarters: P.O. Box 31, Easton, Pennsylvania 18044-0031 USA,Telephone: 001-610-559-3300. www.victaulic.com \iCtaulic* VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2013 VICTAULIC COMPANY.ALL RIGHTS RESERVED. uN 4(l.5() 4 RFV FIRE PROTECTION PRODUCTS --AUTOMATIC SPRINKLERS T n U.hU V38, K5.6 �.I V Adjustable Concealed Standard Spray Pendent Standard and Quick Response V3801 STANDARD RESPONSE V3802 QUICK RESPONSE DIMENSIONS Models V3801,V3802(drawings not to scale) 2%//68 mm Max.Hole r_23AAA, 6o/ mm in.Hole ___.1 I I wiiii 001 iiiiaa� � 25//'/59 mm 1����� �I 1� 11'/38 mm riga '��,4 j;'�A Typical Ceiling Tile �� ����� 1 MINIMUM EXTENSION Finished Surface 33/5"/80 mm _111W_ nia 213/,6771 mm —11 Io �� �sm )� 2751 mm 1/2"/13 mm Adjustment MAII igy.�d Typical Ceiling Tile 31/'/83 mm Cover Plate Finished Surface MAXIMUM EXTENSION AVAILABLE WRENCHES • _.. Sprinkler Type Recessed Concealed Pendent-V3801,V3802 V38-4 or V38-5 www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2013 VICTAULIC COMPANY.ALL RIGHTS RESERVED. �Otalllll0® REIIN 40.50 5 "38, Adjustable Concealed Standard Spray Pendent Standard and Quick Response V3801 STANDARD RESPONSE V3802 QUICK RESPONSE DISTRIBUTION PATTERNS Models V3801,V3802 K5.6 standard concealed pendent distribution patterns—trajectory 10' l•:!'rl ���w • 444 �4 4. 44 6 •' 1.8m .4.. 44 4' \� 4 1.2m • 4• 44, 2' €. 0.6 m • 0 2 4' 6 8' 10' 12' 14' 0.6m 1.2m 1.8m 2.4m 3.0m 3.7m 4.3m NOTES: 1 Data shown is approximate and can vary due to differences in installation. 2 These graphs illustrate approximate trajectories,floor-wetting,and wall-wetting patterns for these specific Victaulic FireLock automatic sprinklers.They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation. Refer to the appropriate NFPA National Fire Code or the authority having jurisdiction for specific information regarding obstructions,spacing limitations and area of coverage requirements. Failure to follow these guidelines could adversely affect the perfor- mance of the sprinkler and will void all Listings,Approvals and Warranties. 3 All patterns are symmetrical to the centerline of the waterway. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. For complete contact information,visit www.victaulic.com 40.50 2558 REV N UPDATED 06/2013 lctauIic® VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2013 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 40.50 V27, K 5. 6 ® FM ® IL,PCBJ �« SEE VICTAULIC PUBLICATION 10.01 FOR DET® Standard Spray; Upright, Pendent and Recessed Pendent " MODELS/S.I.N. V2703 AND V2707 STANDARD RESPONSE MODELS/S.I.N.V2704 AND V2708 QUICK RESPONSE ■ ■ These Model V27 standard spray sprinklers are designed to produce a ■ ■ i^ dM hemispherical spray pattern for standard commercial applications. They are ' available with either standard or quick response bulbs. The design incorporates • . ' ~' state-of-the-art, heat responsive,frangible glass bulb design (standard or quick I F ,r,, response)for prompt, precise operation. UPRIGHT I PENDENT RECESSED The die cast frame is more streamlined and attractive than traditional sand cast •( V2703 AND -(V2707 AND PENDENT frames. It is cast with a hex-shaped wrench boss to allow easy tightening from many -■ V2708) V2704) v2708l (v2707 AND angles, reducing assembly effort. This sprinkler is available in various temperature ■.....,..■, ratings(see chart on page 2)and finishes to meet many design requirements. The recessed pendent should be utilized with a Model V27 recessed escutcheon which provides up to 3/4719 mm of adjustments. SPRINKLER OPERATION The operating mechanism is a frangible glass bulb which contains a heat responsive liquid. During a fire,the ambient temperature rises causing the liquid in the bulb to expand. When the ambient tem- perature reaches the rated temperature of the sprinkler,the bulb shatters.As a result,the waterway is cleared of all sealing parts and water is discharged towards the deflector.The deflector is designed to distribute the water in a pattern that is most effective in controlling the fire. • COVERAGE For coverage area and sprinkler placement, refer to NFPA 13 standards. TECHNICAL SPECIFICATIONS Models/S.I.N.:V2703,V2704,V2707,V2708 Style: Pendent, Upright or Recessed Pendent ACCESSORIES B Nominal Orifice Size: 1 "/13 mm • K-Factor:5.61mp./8.1 S.I.^ Installation Wrench: Nominal Thread Size: 1/2" NPT/15mm • Open End:V27 Max. Working Pressure: • Recessed:V27-2 175psi/1200kPa FM Global Finishes: 0250 psi/1725kPa UL • Plain brass Factory Hydrostatic Test: • Chrome plated 100% 500psi/3450kPa • • White painted** U \ Min. Operating Pressure: 7psi/48kPa • Black painted** ?ill Temperature Rating:See charts on page 2&3. • Custom painted** • Proprietary nickel Teflon*coating** ^_ ) ig MATERIAL SPECIFICATIONS • For 155,200,and 286°F Standard U n h Response Only,wax coated** p t Deflector: Bronze per UNS C22000 Pendent Deflector: Bronze per UNS C51000 For cabinets and other accessories refer to Bulb:Glass with glycerin solution. separate sheet. Bulb Nominal Diameter: • Standard: 5.0 mm NOTE:Weather resistant recessed escutcheons Quick Response:3.0mm available upon request. \ ® Load Screw: Bronze per UNS 065100 ^ For K-Factor when pressure is measured in Pip Cap: Bronze per UNS C65100 Bar, multiply S.I. units by 10.0. Spring: Beryllium nickel * Teflon is a registered trademark of Dupont Co. Exaggerated for clarity Seal:Teflon*tape **UL Listed for corrosion resistance in all Frame: Die cast brass 65-30 configurations. Lodgement Spring:Stainless steel per UNS S30200 • JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Location Spec Sect Para Date Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ictaulic° REV 1 40-10 1 FIRE PROTECTION PRODUCTS- AUTOMATIC SPRINKLERS 4V. 1V t Standard Spray; Upright, Pendent and Recessed Pendent MODELS/S.I.N.V2703 AND V2707 STANDARD RESPONSE MODELS/S.I.N.V2704 AND V2708 QUICK RESPONSE Model APPROVALS/LISTINGS ,.„ .Fy,, „ , 12707 " ' I7 4 ' 8 v 7o8r Orifice Size o Size(inches) 3 3 3 3 3 Orifice13 Size(mm) 5.6 5.6 5.6 5.6 mi 5.6 5.6 Nominal 81 81 81 8.1 8.1 8.1 Nominal K Factor S.I.al K Factor Imperial Response Standard Standard Standard Quick Quick Quick pRecessed Recessed Pendent Upright Pendent Pendent Deflector Type Upright Pendent up to 1/4" Adjustment Approved Temperature Ratings F°/C°by Agency$ 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 35°F/57°C 55°F/68°C 55°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C 55°F/68°C 75°F/79°C 75°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 75°F/79°C Ul 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 286°F/141°C 286°F/141°C 286°F/141°C 286°F/141°C 286°F/141°C 360°F/182°C 360°F/182°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 35°F/57°C 55°F/68°C 55°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C 55°F/68°C 75°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 75°F/79°C ULC 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 286°F/141°C 286°F/141°C 286°F/141°C 286°F/141°C 286°F/141°C 360°F/182°C 360°F/182°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 1357/57°C 155°F/68°C 155°F/68°C 135°F/57°C 155°F/68°C 155°F/68°C 155°F/68°C 175°F/79°C 175°F/79°C 55°F/68°C 175°F/79°C 175°F/79°C 75°F/79°C FM M 200°F/93°C 200°F/93°C 75°F/79°C 200°F/93°C 200°F/93°C 200°F/93°C 286°F/141°C 286°F/141°C 200°F/93°C 286°F/141°C 286°F/141°C 360°F/182°C 360°F/182°C °C°F/57 135°F/57°C 135 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 55°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C 175°F/79°C 175°F/79°C 55°F/68°C NYC/MEA#62-99-E 75F/ ° ° ° 175°F/79°C 200F/93 ° 200°F/93°C 286°F/141°C 286°5/141°C 286°F/141°C 286°F/141°C 286°F/141°C 360°F/182°C 360°F/182°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 55°F/68°C 55°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C 175°F/79°C 175°F/79°C 55°F/68°C CSFM#7690-0531:112 75F/79 175°F/79°C ° ° 175°F/79°C 200F/93 ° C 200°F/93°C 286°F/141°C 286°F/141°C 286°F/141°C 286°F/141°C 286°F/141°C 360°F/182°C 360°F/182°C 135°F/57°C 135°F/57°C 155°F/68°C 135°F/57°C 155°F/68°C 135°F/57°C None 175°F/79°C 175°F/79°C 75°F/79°C 175°F/79°C None LPCB 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 286°F/141°C 286°F/141°C 360°F/182°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 135°F/57°C 155°F/68°C 155°F/68°C 135°F/57°C 175°F/79°C 175°F/79°C 55°F/68°C 175°F/79°C 175°F/79°C 175°F/79°C VNIIPO 200°F/93°C 200°F/93°C 175°F/79°C 200°F/93°C 200°F/93°C 200°F/93°C 286°F/141°C 286°F/141°C 200°F/93°C 286°F/141°C 286°F/141°C 360°F/182°C 360°F/182°C ZSTZ ZSTX K-ZSTZ K-ZSTX 155°F/68°C 155°F/68°CNone 155°F/68°C 155°F/68°C None CCC 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C #Listings and Approvals as of printing.All are approved open,except for areas designated"No". ^For K Factor when pressure is measured in Bar,multiply S.I.units by 10.0 #FM Approved with 1/2"adjustment escutcheon only-quick response www.victaulic.com iCtalili VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. EV 4(1. 02 FIRE PROTECTION PRODUCTS. AUTOMATIC SPRINKLERS 40. 10 K5.6 Standard Spray; Upright, Pendent and Recessed Pendent MODELS/S.I.N.V2703 AND V2707 STANDARD RESPONSE MODELS/S.I.N.V2704 AND V2708 QUICK RESPONSE RATINGS All glass bulbs are rated for temperatures from-67°F/-55°C to those shown in table below. Victaulic Temperature—°F/°C ,. Sprinkler Temperature Part Nominal Temperature Maximum Ambient Classification Identification Rating Temperature Allowed Glass Bulb Color Ordinary A 135 100 S7 38 Orange Ordinary 55 100 68 38 Red Intermediate E 75 50 79 65 Yellow ntermediate F 200 50 93 65 Green High J 286 225_ 141 107 Blue Extra High# K 360 300 182 149 Purple -# M Open No Bulb #Standard response only. All are approved open,except for areas designated"No". —150/65 if wax coated. ORDERING INFORMATION Please specify the following when ordering: Sprinkler Model Number Style Temperature Rating K-Factor -I Thread Size Quantity Sprinkler Finish Escutcheon Finish Wrench Model Number www.victaulic.com VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ��itaull lr'® REV I 40.10 3 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS 4V. 1V V27 K5 6 Standard Spray; Upright, Pendent and Recessed Pendent MODELS/S.I.N.V2703 AND V2707 STANDARD RESPONSE MODELS/S.I.N.V2704 AND V2708 QUICK RESPONSE Al'4/''''0''"40P'4%4'If'' Aft+,,7,i .l''"" A ''', ' - 'x T ks' °fes a WARNING ate. �a ' ,�o- ,•' „' ' �s ,. 2114ter , "�aaY,�:_ �e ems. _ • Always read and understand installation,care,and maintenance instructions,supplied with each box of sprinklers, before proceeding with installation of any sprinklers. c • Always wear safety glasses and foot protection. • Depressurize and drain the piping system before attempting to .‘1? install, remove,or adjust any Victaulic piping products. • Installation rules,especially those governing obstruction, must be strictly followed. 0 • Painting, plating,or any re-coating of sprinklers(other than that sup- plied by Victaulic)is not allowed. Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the current National Fire Protection Association document NFPA 25 that describes care and maintenance -- of sprinkler systems. In addition,the authority having jurisdiction may have additional maintenance,testing,and inspection requirements that n• mustbe followed. If you need additional copies of this publication,or if you have any questions about the safe installation of this product,contact Victaulic World Headquarters: P.O. Box 31, Easton, Pennsylvania 18044-0031 USA,Telephone:001-610-559-3300. DIMENSIONS Standard Pendent—V2707,V2708 Standard Upright—V2703,V2704 1 III— 1,A67 37 mm 2r^/ f--- r� j y — 60 mm "/ T 1 4115/m'm �'� 2/"� LiltII 60 m ® 1"/ Illimmt 25 mm 1/2"Adjustment Recessed—V2707,V2708(drawing not to scale) 2W/60 mm -4—Max.Hole--..- 2/51 '2"/51 mm "•-•Min.Hole - 1- 1 1 Ma"/ I ` + I/l�QlAll!I I I%lDA 34m 1 '�y�l l�� Typical Ceiling Tile j . /) 1 �d7/ IIIF,�a ll P'/� , Finished Surface ��� 30 m 43 mm �:r� MAXIMUM RECESS - 75 mm MAXIMUM EXTENSION • www.victaulic.com viGtsulic VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. REV 0-10 4 FIRE PROTECTION PRODUCTS -AUTOMATIC SPRINKLERS 40. 1 U V27 K5 6Standard Spray; Upright, Pendent and Recessed Pendent MODELS/S.I.N.V2703 AND V2707 STANDARD RESPONSE MODELS/S.I.N.V2704 AND V2708 QUICK RESPONSE DIMENSIONS 3/4"Adjustment Recessed—V2707,V2708(drawing not to scale) 2/e"/60 mm Max Hole —" 2751 mm Min.Hole } isAs"/ + U■■.—®ali 1,A,../ 24 mm Gd/ �Z, �� yp 9 07Ard1,I a i1, 37 mm 18�m /�, f, `�— ` Typical Ceiling Tile I �/�� �;� I�/LI1/1 se"7 -41$ Finished Surface 24 mm MAXIMUM RECESS --- Zs/1s"/ 75 mm MAXIMUM EXTENSION AVAILABLE WRENCHES Sprinkler Type V27-2 Recessed V27 Open End V2707,V2708 Pendent yes yes V2707,V2708 Recessed Pendent yes V2703,V2704 Upright yes yes DISTRIBUTION PATTERNS Models/S.I.N.V2707,V2708 K5.6 standard pendent and recessed pendent distribution patterns—trajectory 1a0 3.0m '. ••„.:°*.**** • • l .., ,` ..• ♦ 1.8m ... f.,,.,n. n�♦ ,.�♦ $ , s ♦ ., i. .,. . 4... .. _ ....., ♦♦ 4' ` 444 • E . • , 1.2m ... `... ,., ♦' .... s... .,. .. ♦ • , ` ♦ 2' i ♦♦ t •♦ 2 4 6 8' 10' 12' 14' 0.6m 1.2m 1.8m 2.4m 3.0m 3.7m 4.3m 7 psi l•• •" 15 psi 30 psi 48 kPa 103 kPa 207 kPa • See notes on next page. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. �Cta______ REV I 40.10 5 V27, K5.6 Standard Spray; Upright, Pendent and Recessed Pendent MODELS/S.I.N.V2703 AND V2707 STANDARD RESPONSE MODELS/S.I.N.V2704 AND V2708 QUICK RESPONSE DISTRIBUTION PATTERNS Models/S.I.N.V2703,V2704 K5.6 standard upright distribution patterns—trajectory 1a 3.0m! . •♦♦♦ •• ♦♦♦ y • 4.♦ 1.2m S i ♦♦ 2' , s ` € ♦♦ 0.6m { ♦ ,. �♦ • 2' 4' 6' 8' 10' 12' 14' 16' 0.6m 1.2m 1.8m 2.4m 3.Om 3.7m 4.3m 4.9m 7 psi •• 15 psi 30 psi 48 kPa 103 kPa 207 kPa NOTES: 1 Data shown is approximate and can vary due to differences in installation. 2 These graphs illustrate approximate trajectories,floor-wetting,and wall-wetting patterns for these specific Victaulic FireLock automatic sprinklers.They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation. Refer to the appropriate NFPA National Fire Code or the authority having jurisdiction for specific information regarding obstructions,spacing limitations and area of coverage requirements. Failure to follow these guidelines could adversely affect the perfor- mance of the sprinkler and will void all Listings,Approvals and Warranties. 3 All patterns are symmetrical to the centerline of the waterway. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. For complete contact information,visit www.victaulic.com 40.10 2544 REV I UPDATED 04/2012 IctauIoC VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 40.10 ., ,, iRE P R p.T. FT),911...,:r.ft.PRU,CTS UT .. A,-- ^8 '' : V27, �L ® �Cµ ,W...,LPCB IE VNIIPO SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS Standard Spray Horizontal Sidewall and Recessed Horizontal Sidewall Standard and MIMINEMIMIMIMMMINIMIMIMIEVEllr Quick Response MODELS/S.I.N.V2709 AND V2710 , il ,: ,::-:,-.°Z,114‘..%. low $7.4 il These Model V27,standard spray horizontal sidewall sprinklers are designed for up to ordinary ■ I l l I` f .n' ■ Hazard per NFPA 13,and can be used for standard or recessed installations.The design provides • _. :\ � a crescent-shaped water discharge pattern for installation along a wall or under a beam or ceiling. ; g The design incorporates state-of-the-art,heat responsive,frangible glass bulb design(standard or - STANDARD HORIZONTAL SIDEWALL ■ quick response)for prompt,precise operation. ■ (v2709,v2710) ■ OIMMIMOMMEMEMMOMOMMMIMEM The die cast frame is more streamlined and attractive than traditional sand cast frames.It is cast with a •,• , a hex-shaped wrench boss to allow easy tightening from many angles,reducing assembly effort. This sprinkler is available in various temperature ratings(see chart on page 2)and finishes to meet many design requirements. The recessed pendent should be utilized with a Model V27 recessed escutcheon which provides up - �' to 3/4719 mm of adjustments. (1 Chl I f g ;' V • zj, RECESSED HORIZONTAL SIDEWALL (V2709,V2710) SPRINKLER OPERATION: The operating mechanism is a frangible glass bulb which contains a heat responsive liquid.During a fire, the ambient temperature rises causing the liquid in the bulb toa expand.When the ambient temperature reaches the rated temperature of the sprinkler,the bulb shatters.Asa result,the waterway is cleared of all sealing parts and water is discharged towards the deflector.The deflector is designed to distribute the water in a pattern that is most effective in controlling the fire. COVERAGE: For coverage area and sprinkler placement,refer to NFPA 13 standards. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date .. Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2010 VICTAULIC COMPANY.ALL RIGHTS RESERVED. iCtaUIic REV I 40.11 1 FIRE PROTECTION PRODUCTS 40. 11 AUTOMATIC SPRINKLERS , V27, Standard Spray Horizontal Sidewall and Recessed Horizontal Sidewall Standard and Quick Response MODELS V2709 AND V2710 ___, TECHNICAL SPECIFICATIONS: ModeIs/S.I.N.:V2709,V2710 ACCESSORIES Style: Horizontal Sidewall or Recessed Installation Wrench: Horizontal Sidewall • Open End:V27 / Nominal Orifice Size: 1/2713 mm Recessed:V27-2 K-Factor:5.6 Imp./8.1 S.I.^ Sprinkler Finishes: Nominal Thread Size: 'k'Y15mm • Plain brass i Max.Working Pressure: • Chrome plated 175 psi/1200kPa FM Global • White painted** 250 psi/1725 kPa ULFlat black painted** • Factory Hydrostatic Test: 100%CP 500 psi/ • Custom painted** 3450kPa • Proprietary Nickel/Teflon* Coating** Min. Operating Pressure:7psi/48kPa Temperature Rating:See chart on page 2. �� i For cabinets and other accessories refer to • MATERIAL SPECIFICATIONS separate sheet. J Horizontal Deflector:Commercial bronze per NOTE:Weather resistant recessed escutcheon _��' available upon request. UNS 022000 ^ For K-Factor when pressure is measured in a' Bulb:Glass with glycerin solution. Bar, multiply S.I. units by 10.0. 11111_,)— Bulb Nominal Diameter: • Standard: 5.0 mm * Teflon is a registered trademark of Dupont Co. 1\_t--) • Quick Response:3.0mm **Also, UL Listed for corrosion resistance in all Load Screw: Low Silicon bronze per configurations. UNS 065100 Pip Cap: Low Silicon bronze per UNS C65100 Exaggerated for clarity Seal:Teflon*tape Spring: Beryllium nickel Frame: Die cast brass 65-30 Lodgement Spring:Stainless steel per UNS S30200 ictaulic° VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2010 VICTAULIC COMPANY.ALL RIGHTS RESERVED. REV I 40.71 2 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS 4U. 11 V27, K5 6 Standard Spray Horizontal Sidewall and Recessed Horizontal Sidewall Standard and Quick Response MODELS V2709 AND V2710 • APPROVALS/LISTINGS Model v2709 V2709 Recessed r,; V2710 2710 Recessed V2710 Recessed Orifice Size(inches) _. Y2" 2 Orifice Size(mm) 13 13 13 13 13 ... Nominal K Factor Imperial 5.6 5.6 5.6 5.6 5.6 Nominal K Factor S.I^ 8.1 8.1 8.1 8.1 8.1 Response Standard Standard Quick Quick Quick Recessed Recessed Recessed Deflector Type Horizontal Horizontal Horizontal Horizontal Horizontal Sidewall Sidewall* Sidewall Sidewall(up to'k" Sidewall(up to 3/4" adjustment) adjustment) 135°F/57°C 1550F/68°C 1350F/57°C 135.F/57°C 35°F/57°C 135°F/57°C UL 17.50F/79°C 55°F/68°C 155°F/68°C 155°F/68°C 155.F/68°C 200°F/93°C 175°F/79°C 175°F/790C 175°F/79°C 175°F/79°C 286.F/141°C 2000F/93°C 200°F/93°C 2000F/930C 200°F/93°C 3600F/18200 286°F/141°C 1350F/57°C 155°F/68°C 135°F/57°C 135°F/570C 1350F/57°C 135°F/57°C ULC 175°F/79°C 55°F/68°C 155°F/68°C 155.F/68°C 1550F/68°C 2000F/93°C 175°F/79°C 17.50F/79°C 175°F/79°C 175°F/79°C 286°F/141°C 200°F/93°C 2000F/93°C 200°F/93°C 200.F/93°C 3600F/1820C 286°F/141°C 135°F/57°C 155.F/68°C 135°F/57°C 135°F/570C 135°F/57°C 155.F/68°C 155°F/68°C 175°F/79°C 55oF/ ° CFM# 200°F/93°C 175°F/79°C 1750F/790C None 020°F/93°C 2860F/141°C 200°F/93°C 286°F/141°C 200°F/93°C 360°F/1820C 1350F/57°C 155°F/68°C 135°F/570C 1350F/57°C 135°F/57°C 1350F/570C NYC/MEA#62-99-E 175°F/79°C 155°F/68°C 155°F/68°C 175°F/79°C 1550F/68°C 155°F/68°C 200°F/93°C 175°F/79°C 200°F/93°C 1750F/79°C 175°F/79°C 2860F/141°C = 200°F/93°C 200°F/93°C 200°F/93°C 3600F/182°C 2860F/141°C 135°F/57°C 155°F/68°C 135°F/57°C 1350F/570C 135°F/570C 135°F/57°C CSFM#7690-01175°F/79°C 155°F/68°C 550F/680C 155°F/68°C 155°F/68°C 200°F/93°C 175°F/79°C 75°F/79°C 175°F/79°C 175°F/79°C 286°F/141°C 200°F/93°C 200.793°C 200°F/93°C 2000F/930C3600F/182°C 360°F/182°C 286°F/141°C 135°F/57°C LPCB#104b/O1 155.F/68°C 35°F/57°C 75°F/79°C 155°F/68°C #104b/02 200°F/93°C None 75°F/79°C None None 286°F/141°C 200°F/93°C 360°F/182°C 286°F/141°C 135°F/57°C 55°F/68°C 35°F/57°C 35°F/57°C 135°F/57°C VNIIPO 75°F/79°C 55°F/68°C 155°F/68°C 550F/68°C 200°F/93°C 75°F/79°C1175°F/79°C 75°F/79°C None 2860F/141°C 200°F/93°0 200°F/93°C 200°F/93°C 360°F/182°C 286°F/141°C CCCf ZSTBS None 155.F/68°C None None None # Listings and Approvals as of printing.All standard responses are approved open. ^ For K Factor when pressure is measured in Bat multiply S.I.units by 10.0 # Light Hazard ONLY www.victaulic.com VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2010 VICTAULIC COMPANY.ALL RIGHTS RESERVED. �Ct'a1UI1G° REV I 40.11 3 FIRE PROTECTION PRODUCTS-- AUTOMATIC SPRINKLERS V27, K5.6 Standard Spray Horizontal Sidewall and Recessed Horizontal Sidewall Standard and Quick Response Models V2709 and V2710 RATINGS All glass bulbs are rated for temperatures from—67°F/-55°C to those shown in table below. Temperature-"F7°C Victaulic Sprinkler Temperature Part Nominal Temperature Maximum Ambient Classification Identification Rating Temperature Allowed Glass Bulb Color 135 100 Orange Ordinary A 57 38 155 100 Red Ordinary C 68 38 175 150 Yellow Intermediate E 79 65 200 150 Green Intermediate F 93 65 286 225 Blue High 141 107 360 300 Purple Extra High t K 182 149 _.$ M Open — No Bulb #Standard response only. All standard responses are approved open. ORDERING INFORMATION Please specify the following when ordering: Sprinkler Model Number Style Temperature Rating K-Factor Thread Size Quantity Sprinkler Finish Escutcheon Finish Wrench Model Number �CtaUI�Ce VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2010 VICTAULIC COMPANY.ALL RIGHTS RESERVED. REV 40.11 4 FIRE PROTECTION PRODUCTS- AUTOMATIC SPRINKLERS `, 40. 11 V27 K5 6 Standard Spray Horizontal Sidewall and Recessed Horizontal Sidewall Standard and Quick Response MODELS V2709 AND V2710 WARNING =-,,,-4-- ,,,-,,,, ,:-,.., ,: :, t : ,, I:1 „ 1 ,„.„,;,,,,,„Nz..,,%1-7. .!, ' 4• Always read and understand installation,care,and maintenance instructions,supplied with each box of sprinklers,before proceeding with installation of any sprinklers. c • Always wear safety glasses and foot protection. • Depressurize and drain the piping system before attempting to install, remove,or adjust any Victaulic piping products. • Installation rules,especially those governing obstruction,must be strictly followed. • Painting,plating,or any re-coating of sprinklers(other than that supplied by Victaulic)is not allowed. 0 Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition.For minimum maintenance and inspection requirements,refer to the current National Fire Protection Association pamphlet that describes care and maintenance of sprinkler - systems.In addition,the authority having jurisdiction may have additional maintenance,testing,and inspection requirements that must Vac be followed. If you need additional copies of this publication,or if you have any questions about the safe installation of this product,contact Victaulic World Headquarters:P.O.Box 31,Easton,Pennsylvania 18044-0031 USA,Telephone:001-610-559-3300. www.victaulic.com ‘Actaulic* VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2010 VICTAULIC COMPANY.ALL RIGHTS RESERVED. REVI 401] 5 FIRE PROTECTION PRODUCTS- AUTOMATIC SPRINKLERS 4V. 11 6 V27, . Standard Spray Horizontal Sidewall and Recessed Horizontal Sidewall Standard and Quick Response MODELS V2709 AND V2710 DIMENSIONS Standard HSW—V2709,V2710 3"/89 mm - 21"757 mm 1 -F-- ;�-iii ,�/ --- I, �'' I 11 mm j�- 32 ,6", /mm I�. I® 8mm-�-- I'��C1 I �,l Iuf L— i/z"Adjustment Recessed—V2709,V2710(drawing not to scale) 11/16"/ 117mm 11/16" 11/15"/ 23/16"/ 43mm 30mm 1yy56 mm��y/ ����// pp 4ffeartgartire fFinished Ceiling I 0 Finished Ceiling 4-12"/102-305mm ,� 4-12"/102-305 mm ' Per NFPA Iy Per NFPA ���///��A 1 ~ J�III 1 2"/51 mm 23/8"/60 mm �� lith` 2"/51 mm 23/8"/60 mm 215/16"/ IC��lil'l Min.Hole Max.Hole ' -.,���i11111 Min Hole Max.Hole 75 mm ', C I 10 re Alizo Finished Surface Finished Surface I ` _..i{ 1---Typical Wall -.{ ~Typical Wall MAXIMUM EXTENSION MAXIMUM RECESS 3/4"Adjustment Recessed—V2709,V2710(drawing not to scale) 15/16"/ 24 mm 7/16" 5/16' a .23/l6"/ 9/16"/18 mm 56 mm 37mm 37mm WASSAITIT ��eit IpA Finished Ceiling I Ift Finished Ceiling 4-12/102-305 mm 4-12"/102-305 mm Per NFPA I 4 Per NFPA t ��II 2^/51 mm 23/8"/60 mm lli!Ili! 2"/51 mm 23/8"/60mm27.;',,. I 215/16"/'I i Ili\• Min,Hole Max-Hole ((.:��ryi1.-l1 Min.HoleMax.Hole 75 mm 'i ili ipr ip Finished Surface A Finished Surface L Typical Wall 4.- Typical Wall MAXIMUM EXTENSION MAXIMUM RECESS a ✓ctaulic VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2010 VICTAULIC COMPANY.ALL RIGHTS RESERVED. REV I 40.11 6 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS 4V■ I p i - .. . Standard Spray Horizontal Sidewall and Recessed Horizontal Sidewall Standard and Quick Response MODELS V2709 AND V2710 AVAILABLE WRENCHES V27-2 V27 Sprinkler Type Recessed Open End Noi escutcheon yes yes With escutcheon f yes DISTRIBUTION PATTERNS Models V2709,V2710 K5.6 Standard Horizontal Sidewall and Recessed Horizontal Sidewall Distribution Patterns-Trajectory i 2.4 m , �• ,,. ♦'' 1.8 m ►♦ 0,6m ♦` 4' 6' 8' 10' 12' 14' 16' 1 ' 20' 22' 2 ' 26' 0,6m 1,2m 1,8m 2.4m 3.0m 3.7m 4.3m5.5m 6.1m 6.7m 7.3m 7.9m 7psi _••_•• 15psi �� 30psi 48 kPa 103 kPa 207 kPa Models V2709,V2710 K5.6 Standard and Recessed Horizontal Sidewall Distribution Patterns-Plan View 2' 4' 6' 8' 10' 12' 14' 16' 18' 20' 22' 24' 26' 28' 0.6m 1.2m 1.8m 2.4m 3.0m 3.7m 4.3m 4.9m6.im 6.7m 7.3m 7.9m 8.5m o' � r ■ ■ 1.8 m ■ ■ 2.4m • ■ ■ • 3.7 m 14' 4.3m - -. ♦♦ 16' 4.9 m 7psi ate•. ... 15 psi 48 kPa 103 kPa 30 psi . 207 kPa www.victaulic.com VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2010 VICTAULIC COMPANY.ALL RIGHTS RESERVED. iCtaLJIiC® REV 40.11 7 V27, K5.6 Standard Spray Horizontal Sidewall and Recessed Horizontal Sidewall Standard and Quick Response MODELS V2709 AND V2710 WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE 1. Data shown is approximate and can vary due to differences in installation. 2. These graphs illustrate approximate trajectories,floor-wetting,and wall-wetting patterns for these specific Victaulic FireLock Automatic Sprinklers.They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation.Refer to the appropriate NEPA National Fire Code or the Authority Having Jurisdiction for specific information regarding obstructions,spacing limitations and area of coverage requirements. Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings,Approvals and Warranties. For complete contact information,visit www.victaulic.com 40.11 2545 REV I UPDATED 07/2010 ictaUIiC VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2010 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 40.11 FireLock® Expansion Plates FOR RECESSED OR CONCEALED SPRINKLERS • The FireLock Expansion Plate for V27,V34,and V36 recessed sprinklers is designed to allow a \ , minimum of 1" lateral clearance between the sprinkler and ceiling opening.The expansion plate _ meets most clearance requirements for seismic applications. Refer to local building codes and L .Y _ the Authority Having Jurisdiction for specific seismic requirements. The FireLock Expansion Plate is compatible with all V27,V34,and V36 recessed sprinklers. The addition of the expansion plate does not affect the takeout dimensions of the V27,V34,or V36 RECESSED recessed sprinkler model being installed. Use of the FireLock Expansion Plate does not alter ""- Listings and Approvals of the V27,V34,or V36 recessed sprinklers. The FireLock Expansion Plate for V26,V27,V36,V38,and V39 concealed sprinklers is designed - - to allow a minimum of 1" lateral clearance between the sprinkler and ceiling opening.The ! f �` ■ expansion plate meets most clearance requirements for seismic applications. Refer to local _■ building codes and the Authority Having Jurisdiction for specific seismic requirements. ■ The FireLock Expansion Plate is compatible with all V26,V27,V36,V38, and V39 concealed ■ sprinklers. Please note,the addition of the concealed expansion plate does affect the takeout ■ CONCEALED dimensions of the V26,V27,V36,V38,or V39 concealed sprinkler model being installed. See ■ - concealed sprinkler plate dimensions on page 2. Use of the FireLock Expansion Plate does not ■ alter Listings and Approvals of the V26,V27,V36,V38, or V39 concealed sprinklers. The FireLock Expansion Plate is available in various finishes to meet many design requirements. TECHNICAL SPECIFICATIONS: Material:Cold Rolled Steel Finishes: • Chrome • White"* • Custom** NOTE:Weather resistant escutcheons available upon request. *"UL Listed for corrosion resistance in all configurations. For escutcheon submittal information, please see appropriate sprinkler model literature. JOB OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2006 VICTAULIC COMPANY.ALL RIGHTS RESERVED.PRINTED IN THE USA. �CCaIUlIC° QCAI Q An OA 1 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS 40.84 - xpansioN _ FOR RECESSED OR CONCEALED SPRINKLERS Aft- a * :3 RECESSED CONCEALED DIMENSIONS 4//114 mm Recessed Sprinkler Plate Max.Hole 37/8"/99 mm _ Min.Hole 1"/25 mm Clearance See Note See Note c>V/ �"/A, Typical Ceiling Tile Finished Surface See Note 1 �V I V Expansion Plate 23A6"/ Recessed Escutcheon 75 mm 5'7 127 mm NOTE Refer to submittal of specific Victaulic sprinkler to be used for other recessed dimensions. DIMENSIONS 47/8"/124 mm Concealed Sprinkler Plate Max.Hole • 4//108 mm• _J Min.Hole 1725 mm Clearance A:11001,1 IBM iii tSee Note Finished Ceiling %873 mm* 5i1/2"/136 mm Expansion Plate Typical Concealed Cover Assembly NOTE:Refer to submittal of specific Victaulic sprinkler to be used for other concealed dimensions. *The sprinkler drop length must be lengthened to accommodate the thickness of the concealed expansion plate. www.victaulic.com ` /cta ulicm VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2006 VICTAULIC COMPANY.ALL RIGHTS RESERVED.PRINTED IN THE USA. vim-'^^""'"'"'w"""""°`""" acv a Aft OA "2 FGRE PROTECTION PRODUCTS- AUTOMATIC SPRINKLERS L0.84 Fir. : ® Expansion . s FOR RECESSED OR CONCEALED SPRINKLERS RECESSED CONCEALED ORDERING INFORMATION Please specify the following when ordering: Finish Quantity Recessed or Concealed www.victaulic.com VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2006 VICTAULIC COMPANY.ALL RIGHTS RESERVED.PRINTED IN THE USA. �Ct`dUlIC® DCA/ Ct nn QA 5 9 .orf`".'.5` .... •. n. w.. +��e_: r.. ... FreLock® Expansion FOR RECESSED OR CONCEALED SPRINKLERS 164 RECESSED CONCEALED WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. US&WORLD HEADQUARTERS CANADA CENTRAL,AND SOUTH AMERICA P.O. Box 31 905-884-7444 1-610-559-3300 Easton, PA 18044-0031 USA 905-884-9774(fax) 1-610-559-3608(fax) 4901 Kesslersville Road viccanada@victaulic.com vical@victaulic.com Easton, PA 18040 USA EUROPE ASIA PACIFIC 1-800-PICK-VIC(1-800-742-5842) 32-9-381-15-00 86-21-54253300 1-610-559-3300 32-9-380-44-38(fax) 86-21-54253671 (fax) 1-610-250-8817(fax) viceuro@victaulic.be vicap@victaulic.com pickvic@victaulic.com UNITED KINGDOM MIDDLE EAST www.victaulic.com 44(0) 1438741100 971-4-883-88-70 111111111011111111111111111111111111 44(0) 1438313883 (fax) 971-4-883-88-60(fax) WCAS-6QEFD2 viceuro@victaulic.be UPDATED 7/2006 40.84 3907 REV BictauI1C° VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2006 VICTAULIC COMPANY.ALL RIGHTS RESERVED.PRINTED IN THE USA. A P5 Q A g7g1§01. 1) P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 100 REVERSIBLE BEAM CLAMP 3/4" MOUTH kiiii711111111M SIZE-3/8"rod-4"pipe max. 1/2"rod-8"pipe max. MATERIAL-Ductile iron. FINISH-Plain,E.G. and H.D.G. LISTINGS- cOu$ LISTED 203-EX 2551 •• FM Approval guide-Pipe Hangers SI FUNCTION-Hanger assembly attachment to steel flange with thickness of less than 3/4". INSTALLATION- Per NFPA 13 with set bolt up or down. Torque-3/8"=60 inch lbs. or 1/2"= 125 inch lbs. In the absence of a torque wrench,engage set bolt finger tight then additionally tighten 1/4 turn. Caution-Do not over tighten set bolt. FEATURES _= *Maintains CONSTANT HANGER CENTER-LINE,with set bolt up or down. *Flat throat back to prevent twisting on structure during installation. ORDERING-Part#,rod size and finish. 7/09 ZEgg M P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 300 RING HANGER 1 ,, .. .4.. „._ - ,,,, ,,,, , , „ , , , , „ , , , ) , , , ) , / , / ,,,,' 1 thru 4 Inchp i e 1/2&3/4 Inch pipe p LISTED FOR STEEL/CPVC 5 thru 8 inch pipe NFPA 13 UL 1 WT. 5 WT.+250 TEST PIPE ROD LOAD 1 3/8 30.75 403.75 750 11/4 3/8 43.95 469.75 750 11/2 3/8 54.15 520.75 750 SIZE-ROD-3/8" or 1/2" 2 3/8 76.95 634.75 750 SIZE-SYSTEM PIPE- 1/2" thru 8" 21/2 3/8 118.35 841.75 850 MATERIAL-Carbon Steel,Mil. Galvanized to G-90 spec. 3 3/8 162.30 1061.50 1050 LISTING/APPROVAL- 4 3/8 246.00 1480.00 1500 5 1/2 349.45 1996.75 2000 CON LISTED 203-EX 2551 1"-8" 6 1/2 476.35 2631.75 2650 <>Approval guide-1"-8" 8 1/2 711.00 3805.00 4050 OSHPD OPA-0601 See Website. CONFORMS WITH:Federal Specification WW-H-171E,Type 10. Manufacturers Standardization Society ANSI/MSS-SP-58 Type 10. MAXIMUM TEMPERATURE-650°F. FUNCTION-Pipe hanger component of an AFCON hanger. To support steel,CPVC or copper pipe. INSTALLATION-Per NFPA 13, 13R, 13D,these instructions and PIPE A B 1 1.8]93 2.5259 the CPVC or copper pipe manufacturers instructions. 1,4 2,382 2.7850 FEATURES- T2 2.26]3 2.970 * Sized and listed exclusively for use with#310 Surge Restrainer. B 2 2.60 46 3.25'6 A * Band edge is offset for EASY pipe insertion. / SII/ SII✓ 3 3.7845 4.4311 2112 3.4920 4.1150 * Custom fit swivel nut for better retention in ring. � 4 4.3582 4.9992 ORDERING-Part#,pipe size. 6 6 0666 6.6'6° 8 7.5768 8.3290 a 11/09 �010: 0 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 077 ATTACHMENT FITTING LOCKING I........■........■.................. 11■ ; it 17/32" ; ; ▪ 17/32" ■ I %.4.Qirns ill • e . '"Ntilli e° ■ 0 ■ o■ I \.. V I ■ I • o o I SIZE-7 BRACE PIPE I-1" and 1 1/4" Sch.40 MATERIAL-Carbon Steel,Ductile Iron or S.S.(Type 304). FINISH-Plain or E.G. LISTING/APPROVAL- 0D$203A-EX2625 LISTED FM Approved <>OSHPD OPA-0601-07 See Website. Horizontal Load Ratings FUNCTION- Structure attachment fitting of an AFCON sway brace assembly. ase MFM UL Sway brace assemblies are intended to be installed in accordance with DuctMaterial NFPA 13 and the manufacturer's installation instructions. Steellle 1--- 2015 INSTALLATION-Per these instructions including NFPA 13 and 13R. -_ 2015 Load rating-see chart. The required type,number and size of fasteners used to structure attachment fitting shall be in accordance with NFPA 13. ASSEMBLY Combine with proper AFCON components. Insert brace pipe into fitting against the pivot bolt. Tighten set bolt until head contacts bracket. Torque pivot bolt to 40 ft. lbs. FEATURES * Swivel allows attachment at any angle. *Visual inspection,verifies proper installation. *Larger fastener hole available.-Consult factory. ORDERING-Part#,pipe size and finish. Specific AeFCOeNproducts are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners,resulting ine a listed sway brace,restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER-AFCON will NOT warrant against the failure of its products when used in combination with other products,parts or systems not manufactured or sold by AFCON.AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect,incidental or consequential damages of any kind,including but not limited to loss of business or profit,when non-AFCON products have been,or arc used. 6/11 4Z7., 0 0E P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org • 087 SWAY BRACE ADAPTER 6' Maximum 1/2' `of • 07/7 v 'v . 078--/, 1/2" % 01 111111111111111MIMMIMMIN ,.` . 410 er— SIZE- 1/2"bolt. MATERIAL-Carbon Steel or Ductile(Pictured). L----1 FINISH-Plain or E.G. "� ,. PATENT-No.6,629,678. </_ LISTING/APPROVAL- cOus 203A-EX 2625,203-EX 2551 DSTED FM FM Approved-1950 Q OSHPD OPA-0601 See Website. FUNCTION-Sway brace adapter for an AFCON sway brace assembly. Designed to attach to the vertical or horizontal flange of a steel structural member. IllW7 Sway brace assemblies are intended to be installed in accordance with NFPA 13 and the manufacturer's installation instructions. Additionally listed as an 6"hanger attachment. INSTALLATION-Per NFPA 13 and these instructions. Load rating-see chart. Combine with proper AFCON components-see disclaimer below. 087D Horizontal Load Ratings a �� °S FM The structural members design will dictate specific attachment criteria. LISTED ASSEMBLY- See drawing. Parallel 30°thru 90° 2765 3250 Install set bolts finger tight,then additionally tighten 1/2 turn or torque to 125 inch Perpendicular 30°thru 90° 2765 3250 pounds. Attach AFCON sway brace assembly with 1/2"bolt. FEATURES *Design conforms to angular geometry at panel point. 087S Horizontal Load Ratings a �� us * Fits 1/2" max.flange thickness. LISTED ORDERING-Part#and finish. Parallel 30°thru 90° 2015 - Perpendicular 30°thru 90° 2015 Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners,resulting in a listed sway brace,restrainer or hanger assembly. Be advised the following warranty restriction will apply.DISCLAIMER-AFCON will NOT warrant against the failure of its products when used in combination with other products,parts or systems not manufactured or sold by AFCON.AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect,incidental or consequential damages of any kind,including but not limited to loss of business or profit,when non-AFCON products have been,or are used. 9/11 , a5 v.v 01) P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 411 SWAY BRACE FITTING Part#077— 411M ® 1 7 Part#078 44i ti /# Nrilr ORT Part#411 — �� f f SIZE-SYSTEM PIPE:Nominal Pipe Size ` t � 1" -12" varies-see chart `! MATERIAL-Carbon Steel FINISH-Plain or E.G. Horizontal Load Ratings PATENT-No.7,140,579 Size UL FM LISTING/APPROVAL 1"-8" 2765 2700 10" 2765 --- Ous us 203A-EX 2625 usreo 12" 3740 --- 0 Listed only for use with AFCON products. •••a���FM Approved OSHPD OPA-0601 See Website. System Pipe Size UL FUNCTION-Longitudinal fitting of an AFCON sway brace assembly. 1"- 12" Sch.40 Steel Sway brace assemblies are intended to be installed in accordance with 1 1/4"- 12" Sch. 10 Steel NFPA 13 and the manufacturer's installation instructions. Size FM INSTALLATION- Per NFPA 13 and these instructions. Load rating-see chart. 1"-8" Sch.40 Steel Align brace pipe parallel to system pipe. 1"-8" Sch. 10 Steel ASSEMBLY-See drawing. 1"-8" Lt. Wall Steel Combine with proper AFCON components. Tighten until fastener flanges engage or torque to 40 ft. lbs. 078 is a preferred assembly component. FEATURES * Improved assembly-ears compress for superior strength. * Patented design-eliminates bending of ears during installation. * Visual inspection-proper installation when fastener flanges engage. ORDERING-Part#,pipe size and finish. Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners,resulting in a listed sway brace,restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER-AFCON will NOT warrant against the failure of its products when used in combination with other products,parts or systems not manufactured or sold by AFCON.AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect,incidental or consequential damages of any kind,including but not limited to loss of business or profit,when non-AFCON products have been,or are used. 1/11 .4Zg7g-g§,§il P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 001/020 SWAY BRACE FITTING MODEL E Part#077 %' �' 1 l. `'I„ '►.� 1"min. .p �a c Horizontal Load Ratings Size © ® `ani" SIZE-SYSTEM PIPE: Nominal Pipe Size Soh.10 Soh.40 Sch.10-40 Steel 1" thru 4" Sch. 10 and Sch.40 1 250 1000 2015 11/4 250 1000 2015 SIZE-BRACE PIPE: 1" or 1 1/4" Sch.40 1 1/2 250 1000 2015 MATERIAL-Carbon Steel or S.S.(Type 304). 2 loon lino 2015 2 1/2 800 1300 2015 FINISH-Plain or E.G. 3 Ron 1300 2015 LISTING/APPROVAL 4 800 1500 2015 c 41. as 203A-EX 2625 LISTED Listed only for use with AFCON products. Special Note:Listed as restraint device on 1"thru 2"Allied Dynaflow per NFPA 13. FM FM Approved OSHPD OPA-0601-07 See Website. FUNCTION- Lateral fitting of an AFCON sway brace assembly. Sway brace assemblies are intended to be installed in accordance with NFPA 13 and the manufacturer's installation instructions. INSTALLATION-Per these instructions including NFPA 13 and 13R. Load rating-see chart. Align brace pipe perpendicular to system pipe. ASSEMBLY-See drawing. Combine with proper AFCON components. Insert brace pipe through rod bend and under channel bracket to achieve minimum 1"extension. Tighten hex nuts until gage spring lays flat and torque to 165 in.-lbs. FEATURES *Visual inspection,verifies proper installation. ORDERING-Part#,size-system pipe,size-brace pipe and finish. fi" Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners,resulting in a listed sway brace,restrainer or hanger assembly. Be advised the following warranty restriction will apply.DISCLAIMER-AFCON will NOT warrant against the failure of its products when used in combination with other products,parts or systems not manufactured or sold by AFCON.AFCON shall NOT be liable under any circumstances whatsoever for any director indirect,incidental or consequential damages of any kind,including but not limited to loss of business or profit,when non-AFCON products have been,or are used. 8/11 P.O. Box 3365 South EI Monte, CA 91 733 626.444.0541 Fax 626.444.3887 www. Afcon.org 400 RISER CLAMP IRON PIPE A PIPE STOCK MAX.REC. c —+�---Mite, SIZE A B C SIZE LOAD LBS. 1 1/2" 10::: 3/8" 1 1/2" 3/16"x 1 ::: 255 2" 10 3/8" 2" 3/16x1 255 5" 14 1/2" 1/2" 4" 1/4"x1 1/2" 1160 6" 15 1/8" 1/2" 4 1/2" 1/4"x2" 1570 8" 181/2" 5/8" 513/16" 3/8x2" 2500 NOTE:MAXIMUM TEMPERATURE:650°F SIZE- 1/2 thru 20 inch pipe. MATERIAL-Carbon Steel. FINISH-Plain, E.G.,H.D.G. and S.S. LISTING/APPROVAL- c®,. EX 2551 11/2"-8"pipe. OSHPD OPA-0601 See Website. CONFORMS WITH: Federal Specification 1. WW-H-171E,type 8,3/4 thru 20 inch,and ",41 Manufacturers Standardization Society SP-69,type 8. FUNCTION-Used for supporting vertical piping. ORDERING-Part#,pipe size and finish. 1/08 BELLS POTTER The Symbol of Protection PBA-AC & MBA-DC UL,ULC,and FM Approved Sizes Available: 6"(150mm),8"(200mm)and 10"(250mm) itapH, ) Voltages Available: 24VAC 120VAC 12VDC(10.2 to 15.6)Polarized 24VDC(20.4 to 31.2)Polarized Service Use: Fire Alarm General Signaling Burglar Alarm Environment: Indoor or outdoor use(See Note 1) -40°to 150°F(-40°to 66°C) (Outdoor use requires weatherproof backbox.) Termination: AC Bells-4 No. 18 AWG stranded wires DC Bells-Terminal strip 0 * Finish: Red powder coating Optional: Model BBK-1 weatherproof backbox Model BBX-1 deep weatherproof backbox These vibrating type bells are designed for use as fire,burglar or general Notes: signaling devices. They have low power consumption and high decibel 1. Minimum dB ratings are calculated from integrated sound pressure ratings.The unit mounts on a standard 4"(101mm)square electrical box measurements made at Underwriters Laboratories as specified in UL for indoor use or on a model BBK-1 weatherproof backbox or BBX-1 Standard 464. UL temperature range is-30°to 150°F(-34°to 66°C). deep weatherproof backbox for outdoor applications. Weatherproof 2. Typical dB ratings are calculated from measurements made with a backbox model BBK-1,Stock No. 1500001. conventional sound level meter and are indicative of output levels in an actual installation. 3. ULC only applies to MBA DC bells. Size inches Voltage Model Stock Current Typical dB at Minimum dB at (mm) Number Number (Max.) 10 ft.(3m)(2) 10 ft.(3m)(1) 6(150) 12VDC MBA126 1750070 .12A 85 76 8(200) 12VDC MBA128 1750080 .12A 90 77 10(250) 12VDC MBA1210 1750060 .12A 92 78 6(150) 24VDC MBA246 1750100 .06A 87 77 8(200) 24VDC MBA248 1750110 .06A 91 79 10(250) 24VDC MBA2410 1750090 .06A 94 80 6(150) 24VAC PBA246 1806024* .17A 91 78 8(200) 24VAC PBA248 1808024* .17A 94 77 ..•I ZSp�. ,.21 A. '•.P Ai�1•.lel a:•..1 A-.•....4.........75.•.•. ■ 6(150) 120VAC PBA1206 1806120* .05A 92 83 j •�7266'}' ' "P*BA1l68" IS*•�1-A7s. •••99••• .....g�...... 10(250) 120VAC PBA12010 1810120* .05A 99 86 All DC bells are polarized and have built-in transient protection. *Does not have ULC listing. In outdoor or wet installations,bell must be mounted with weatherproof backbox,BBK-1 or BBX-1.Standard electrical boxes will not provide a weatherproof enclosure.If the bell and/or assembly is exposed to moisture,it may fail or create an electrical hazard. Potter Electric Signal Company,LLC•2081 Craig Road,St.Louis,MO,63146-4161•Phone:800-325-3936/Canada 888-882-1833•www.pottersignal.com PRINTED IN USA MFG.#5400776-REV Y PAGE I OF 2 5/08 . , P POTTER BELLS ® The Symbol of Protection PBA-AC & MBA-DC Bells Dimensions Inches(mm) Wiring(rear view) Fig. 1 Fig.3 A.C.BELLS ]�" WHITE(IN) Ailill WHITE(OUT) (250) i0 1^—�1—-� 8" r , , (200) I FROM CONTROL 6 PANEL OR(11) � PRECEDING BELLtillkiji 1 / _ . r_ BLACK(]N) _l/ BLACK(OUT) CAUTION: 2))/I6+= WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND OUT LEADS AS SHOWN. (68) DWG#776-1 NOTES: I.WHEN USING AC BELLS,TERMINATE EACH EXTRA WIRE SEPARATELY AFTER LAST BELL. 2.END-OF-LINE RESISTOR IS NOT REQUIRED ON AC BELLS. DWG,/776-I Weatherproof Backbox Dimensions Inches(mm) Fig.2 FACP Box has one threaded 1/2"conduit entrance i --I— igt Iii IIIL11.. C 5 3/4" 0 _ 3 3/8" 5" J. (146) (86) (127) _ To Next Device or End-of-Line ..i -J �— � ��■� Resistor 1 5/8" 3 3/8" 41) (86) f- 4 1/4" ,i 08 ) Installation DWG#776-2 1. The bell shall be installed in accordance with NFPA 13,72,or local AHJ.The top of the device shall be no less than 90"AFF and not less than 6"below the ceiling. 2. Remove the gong. 3. Connect wiring(see Fig.3). ' a / 4. Mount bell mechanism to backbox(bell mechanism must be OD mounted with the striker pointing down). 5. Reinstall the gong(be sure that the gong positioning pin,in the 01. mechanism housing,is in the hole in the gong). o �� 6. Test all bells for proper operation and observe that they can BBxa ti be heard where required(bells must be heard in all areas as designated by the authority having jurisdiction). Failure to install striker down will prevent bell from operating. PRINTED IN USA MFG.#5400776-REV Y PAGE 2 OF 2 5/08 (,-;lif., ,,F.',1,i,-- ,';,':* -,-*',,,,,,,i,,,,,,.. 4,,!,,''.. -- ': ,, - - -- - 1 - ci ' ,$ Ed r b. ae y;,r'' 4 04 0. 0 ;,,k ,,.��;. t ,...0:0,0,04,41;;:•,,,,%,,,,,•44: •••=..!..'# t. r. Na,, ,; Ductile Iron Threaded Fittings 5 C,. . ,oF--,-,'", ,_4. m,f ,:iia'?::*;�C,#�.��.,W. ,. ;�n:,. ... *C"IfOlfilea CI » • The branded Ductile Iron threaded fittings are UL Listed and FM Approved at 500 psi • Rated to 300 WSP UL • Ductile Iron castings conform to ASTM A536 C US • Fitting dimensions conform to ASME B16.3 LISTED • Bushings and plugs conform to ASME B16.14 41/> • Fittings are 100% air tested APPROVED • NPT threads on all fittings conform to ASME B1.20.1 • Independent lab verification that fittings meet applicable chemical &physical properties • Manufacturing facilities are ISO 9001:2000 and ISO 14001 Temperature Working Pressure,.Nonshock PSIG Degrees F 300#Class Threaded Fittings -20 to 100 500 200 480 25fl . 0: • s 300 440 3 420 400400 450 . 3 0 500 360 550 n . 840 600 320 650 300 ,. , ' 1 ucti e ron fittings - ass I I I 7 ifa r cI3us A Fig. 35E 3-90°Elbow LISTED APPROVED �� Size Part Number: a Packing i Ile ht 9 IN - 1N Inner, ' Master .LB --1 '• 1/2 35E 3004 1.13 100 200 0.2 11 i 7., '_1- 3/4 . .. " 5E-0006 , 31 4,, PO 14" _ //moi I � k� ... �� �, '_"x�� :� ��. � / A 1 35E 3010 1.50 40 80 0.5 I■li j i i-1/4 7.-''''' '_ 0012 'fit'' " .r, 1-1/2 35E 3014 1.94 18 36 1.1 1" 2 h+ , 44...t-4E4029. :114-,z.'.4g,5),, 1""., 0' .,. 2c1 M'', 7 2-1/2 35E 3024 2.70 4 8 3.2 Fig. 35RE3- 90°Reducing Elbow B Sizer A g Packing Wei ht ' ' Number 9 lig .row,--...,� ,n IN ." 1N' IN" inner;"'Master,.:, LBn,.": i•� 3/4 x 1/2 35RE3006004 1.20 1 22 80 160 0.3 . .. , 0 ,x 2 va3 Ep1 ©4 - z ,� 1$6 0 140 t' WA. �/ A 1 x,.314 35RE3010006 _1.38, 1.45, 50 100 0.4 1'q'�� ; 1i41/2 " 3 E 41004 144` , ,1.A 1".53 . �I la ,` ,s,: Ex t=;�+ .+' t..s.. "� � 0754,„. 1-1/4x3/4 35RE3012006 1.45 1.63 35 70 0.6 va 17)/4:1rr". f`***1 1% ,' .6 5 '07: a7 s : . '' 0 1-1/2 x 1/2 35RE3014004 1.52 1.75 30 60 0.6 "; fljiiz s3 -*4010,00f' 7, "`. r "45 . "15, f: 1-1/2 x 1 35RE3014010 1.65 1.80 20 40 0.8 -1*4,114 3 E 1 a�I .' 1I.8 A° 1,/,':t$'8 .µµ= 10 t 6" 41 . i 2 x 1/2 35RE3020004 1.60 1.97 18 36 1.0 .- ' ?`xi4 ` = 4.§R, .f b. , ; . 16r 'iw = k9?: * 1 8is 36V 1#; 2 x 135RE3020010 1.73 2.02 16 32 1.2 ti , " x -,1/4 ,. 10300,24,9:1 #;„,K 1..00 i 10 .,s F4 '4. 4 ., i‘,',1' 2 x 1-1/2 35RE3020014 2.02 2.16 10 20 1.5 x -10, x -1# °,3= *414 `14 �:16 f ,1 . .: 2, x7,_,. 1: IP ;�. : 2-1/2 x 2 35RE3024020 2.39 2.60 6 12 2.5 Fig. 35F 3-45°Elbow Size : ; A" °, Packing° ' r Weigh Ii 't Part�w ber ry ; .� InnerMaster 7 / , ok1/2 35F 3004 0.88 150 300 0.2 #,40.444, 4 ,,m3` 3*i., 1' 0. ': $0ms`s: ,: / "v . .,u..35F 3010/� -�� 1 1.13 40 80 0.5 '•I ,) IA 1 1/2 35F 3014 1.44 20 40 1.0 , A_..,A `3F 3�0 fir 3 1 # : 41 0 ' - 1. 2-1/2 35F 3024 1.95 4 8 2.7 Fig. 35T 3- Tee Size Part Number racking x Weight lisle( 1N °r xi ; IAN , inner , . ,.,Masterla .. ...N. ii- iA 1/25T3004 1 13 80 160 0.3 ' 3l14 - 35 366. f~1 3�f ' , b0,f ,u64 ". ,,,:.513513010 1 50 25 50 0 7 ��`�.� 1,,z1/44.-' M 31 30120c1 10 A A 1-1/2 3513014 1.94 10 20 Illb 1.5 ,? 5:r � 381;30264*, ""' m 22' : _ 73. ;x,56 ,Y . -*� ,z(. 2-1/2 351 3024 2.70 4 8 4.3 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com -'ICI '''::::'' Ductile Iron Fittings - Class 300 UL/FM c (21us LISTED APPROVED Fig. 35RT3-Reducing Tee a __ . Site .i7,,„ A .;, B :. C. Packing. Weight _ Partumber Imp r � o: �� ;� :1N IN � its �Inner ,Master'-` -,''t131., 1 \1.1 C 3/4 x 1/2 35RT3006004 1.20 1.20 1.22 60 120 0.4 - 1 (1/2 .. :t,ef AR01 0b04 1.29„.:ft-k 1 a .;166 x. _. 414, ,; 9 6` - - �-- II of 1 x 1/2 x1. 35RT3010004010 1.50 1.36 1.50 30 60 0.6 W�ti��� \ 11.x 4/4 .," ,3 3RT34i1 00 1..38 1 tv At,: „ 2 50 T, ,:.. 1 x 3/4 x 3/4 35RT3010006006 1.38 1.31 1.45 35 70 0.6 u. B A X-::',1!,,,,--.'-f.:'1-., ...; -:$�p0 6 1 5o.,j_. r_14, , 5 ::;!..2 .,..,...i.' _.x 5O 01; 1-1/4 x 1/2 35RT3012004 1.34 1.34 1.53 20 40 0.8 . ; y,1 7 ..2 59.t . .Q 9 1 1/4x1x I=�1/4�, 3�T �� n:44�2 �;.��,, W� ,. � : 1-1/4x3/4 35RT3012006 1.45 1.45 1.62 15 30 0.9 1-1/4 x"3/ w 1x=1/4 ..3 =8�1120,p6012.. 75 4 "T 1 , $.20 , °„ 40r, " , -4 .;; 1-1/4 x 1 35RT3012010 1.58 1.58 1.67 15 30 1.0 `... 111/4 it x 1/2. 3S T8 12 fl964 1,34. 1 ` `e 1 25''„ 007:4' ' O y 1-1/4 x 1 x 3/4 35RT3012010006 1.45 1.38 1.63 20 40 0.8 .�1i4i1‘ RT291*6049 'l,* r 1.' v 1'0 ,, ? . .° 0 :, 709 1-1/4 x 1 x 1-1/4 35RT3012010012 1.75 1.69 1.75 15 30 1.0 1,1 x 11 T, R' !x1 i 4 T x141. $ 1 f T 4:4::::!:4,4;4!:4,4;4:4,',A,P7 1-1/2 x 1/2 x 1-1/4 35RT3014004012 1.81 1.56 1.88 24 48 1.1 1-114/ 1- , 5 .'.i Iip ®1 •6� ' $ :5,..:.,'2'..':*1 ',.:4: 1 :i 1-1/2 x 3/4 35RT3014006 1.52 1.52 1.75 16 32 1.1 1-f/2x /4r?. 1.. l 0 ...w1�.n.. 4 6 X 188 .',4: 0 ` .;,,47.1',' " T ;. 1-1/2 x 3/4 x 1-1/2 35RT3014006014 1.94 1.75 1.94 18 36 1.2 1 } " aRf 0140 ;, :Y„ 6. ,; 80 7> ,.12. . '.n. 4.m. ..., 1 2 1-1/2 x 1 x 1/2 35RT3014010004 1.44 1.25 1.69 20 40 0.8 11 1 3 5. r `a ic1 -,,..,.e...,.::,. Al$40 44,70);:;:, 16 :; ' 2 ,...,:-„A",. .'.... 1 1/2 x 1 x 1 35RT3014010010 1.65 1.50 1.80 16 32 1.0 'i4 f/2 ,1I r 0 b31 012,v { 2 -' f0 'x'88"'" 12 x .:,17i4':...7: 1 ,,i 11. 1-112 x 1 x 1-1/2 35RT3014010014 1.94 1.80 1.94 12 24 1.3 14 2 x -i ~.. !443 .4 ,.1' 8 . Egis 1.8:$ 12~n .24 T.' ,1 ?. 1-1/2 x 1-1/4 x 1/2 35RT3014012004 1.41 1.34 1.66 16 32 0.9 14/2.4 .( x 4, 5 0 0TO:.,,,:::-...,,,...40,.. T4,7 z..,, '"!).6.,'....r.''. ::-.W71,-,.:2 , 1 1-1/2 x 1-1/4 x 1 35RT3014012010 1.65 1.58 1.80 16 32 1.1 . 1-,1/2 x 1 4 1 �...'"R .14 ;1 2 ;'1 1% 1.714,' t88 :.: 14.4 4,., '1 34 1-1/2 x 1-1/4 x 1-1/2 35RT3014012014 1.94 1.88 1.94 14 28 1.4 1�- 5 0 .E . ,< ,:i4 ..: ?, 4 3 �'4:-g '''':",:',: :C. ':i 2 x 3/4 35RT3020006 1.60 1.60 1.97 10 20 1.6 ' 4t,, 0 `I1I3 7 , !3 3 4' !0 .. 8 , 46 1 2 x 1 x 2 35RT3020010020 2.25 2.02 2.25 8 16 1.9 ak ,44):11.i74''' x3T3P,°, 2 '',:''',':*•.:e..: 19Q 04 f:„ W . tx lieV 3.a 2 x 1-1/4 x 2 35RT3020012020 2.25 2.10 2.25 8 16 2.0 1 fix .7481113 If' , .. .,.:, .1* 2 x 1-1/2 x 1/2 35RT3020014004 1.49 1.41 1.88 10 20 1.3 2x 1-1>t ; 35 Tab 00 4,006 ;1 61: -1:4U.75.4f.,; ,.,3.14 M,r. . 1, ';.,,rn1 2 x 1-1/2 x 1 35RT3020014010 1.73 1.65 2.02 8 16 1.5 2 x ::1/2 x 1`I4. 3 T3 0040 83 ` 2- , :f, 8`4 74:1 o-: fti lig..;;Aii 2 x 1-1/2 x 1-1/2 35RT3020014014 2.02 1.94 2.16 8 16 1.8 Fig. 35BT3 Bull Head Tee Sizes ' B Packing ; Weight Part Number In : IN Inner j Master' .B . 01 i :1�1 �, C I I -/' 1 C 3/4 x 1 35BT3006010 1.45 1.45 1.37 30 60 0.6 dill -- - %1X11,1/4; 30T lei 2; i"1:# " 1 ' .,!.l, t: .` - ' Ti 4b -... A.§71,7f.:.'. ,,,,,�,,,, l''''","'''''''' x 1-1/2 35BT3010014 1.80 1.80 1.65 15 30 1.0 e A B 1 1/4 1 t-1.QQ. 3 87801 01 014., , 1.88 h„ 1,$0 i.82 ,1.5 ". .,x.30. i;1 2.. _ 1-1/4 x 1-1/2 35BT3012014 1.88 1.88 1.82 15 30 1.3 1-1/4 0 ';;4; 5BT303.120 .. ,1 a:M 210 :`.2.14.T$- ..,.1490,,,,;.` :.4.10,4:,,..:f { 0 . i 1 6 1-1/2 x 1-1/4 x 2 35BT3014012020 2.16 2.10 2.02 10 20 1.8 "..",i',.."4,,..1/21 ' 39I t4 4 11 em , #16 *" 1;:,02:i.,,, ''''''''b',.:,, '"":i'r,- SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com Ductile Iron Fittings - Class 300 UL/FM fr" *41 4-rik c my us LISTED APPROVED • A Fig. 35CP3-Straight Coupling with Ribs Part Number 1.8 < , Size 2' A 4 Packing .41/11eigi!t, ' < IN <, A - IN Inner Master - - 1/2 35CP3004 1.38 200 400 , 0.1 3/4, , 35.09„30;()6,. 100 200 1 35CP3010 1.75 60 120 0.4 1114. N '35CY3Q120 200b000 " 79 07.5 1-1/2 35CP3014 2.19 25 50 0.7 ,4§6p3Q20". 45 29 11, 142 2-1/2 35CP3024 3.00 9 18 2.2 Fig. 35RC3-Hex Reducing Coupling Size A 2 A -Packing Weight JN fart Nurtijier, A A IN 'Inner Pilaster 4 LB N7-7-70. 4, 5 k InrA 1 x 1/2 35RC3010004 1.69 80 160 0.3'1414;314' 'E. A,34ti06.bit00k .q4"."113'9417 :Oa 4 z.4 4 '0.04 r 1-1/4 x 3/4 35RC3012006 2.06 40 80 0.6 kg--NA 23(,1todih0x), -„.StiotbS5o*, 4E14-2;41 -40 Fig. 35HB3-Hex Bushing Size - PartXutiber A 4 WeightB IN <4 " - e-, Inner vaster LS x 1/2 35HB3010004 1.06 180 360 0.2 - 14‘3/4,-44' 160:1340:1-4\i it" 4.z; 4.11.05... A .;,A *0 AA lit 9.1 1-1/4 x 1 35HB3012010 1.19 90 180 0.2 1,112.;1 'g35k-IE401l0tO r1'45: 4; K75 460* 1-1/2 x1-1/4 35H83014012 1.25 75 150 0.3 ,151ii402Q914, ,043: 49 64§ .1.1 2 x 1-1/4 35HB3020012 1.38 40 80 0.6 wt," .4.5748 di)24.0:14 ":41844" 4,s, lk 49 A 0:9 Fig. 35SP3-Square Head Plug =1; Size -"" A Packinó Weight Part Numbe IN 'inner A 'Master 1/2 35SP3004 0.94 600 1200 1, 0.07 fi(44 IA -1" 7,.2/1:' :22 41, -25§,P316.;< *4< 4:7 11 't5q1 ,4 4A '60,1-44A44, 1 35SP3010 1.25 200 400 0.1 1:711* 'z :.?5$1531'-',44?,-, 170374 "100A- 162 49.3 1-1/2 35SP3014 1.44 80 160 0.4 2 t ;35:60602.9: 4' 17567, ,0450 79.6fr" ':0"- 00.61* Fig. 35U3- Union with Brass Seat A Size " A 4, Packing Weight"' PartNumber IN IN, inner Master < LB 1 35U 3010 2.19 20 40 1.0 1-1/4 4 5U3025 ;<.?e,- 20 t. 15 0 4,2 4 '" 1-1/2 35U 3014 2.62 10 20 1.7 2xlekk *850 3020'i AA.1., 6:16A, Aj6 12 " " SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • wwwsmithcooper.com tiPi ,' '$ Ductile Iron Fittings - Class 300 UL/FM T.. red c 13 us 11> LISTED APPROVED A A Fig. 35X 3— Cross V— � size Pail Number AN . Packing Weight \,d� IN° Inner Master LB � fry `�.� I �� A 1 35X 3010 1 50 20 40 0.9 y - I - t5X 430i ' ,1::7`5 -, ---i--- �� 1 =I 1-1/2 35X 3014 1.94 8 16 1 8 A 5 2 6. 1221 ; r ...t � ' �� � 35X�02tI. Ao � tII E B f B Fig. 35RX3 Reducing Cross A g Packing ,Weightxm. .,, Sine ,��!94IA Part Numller .._IN, 0. Inner,; Mas eery:z , . r:. 1 1 1-1/4 x 1 3;1)(3°112010 1.67 1.58 15 30 1143.2 — ''''''''I'12/2x"1 1 /4" 1-11. _ '3 I a r-°� `1 Batt/ 4.,1.1P . '110 ' `� . IA 2 x 1 35RX3020010 2.02 1.73 8 16 2.0 fpr Fig. 35C3— Cap Wei ht Size{ A Packing q •�..� _ w nr, Part Number m N . Inner ''. Master LB itlEMP4 1/2 35C 3004 0.87 300 600 031 A 7 ?0 220 1, I I I I� 1 35C 3010 1.16 110 0 2 4 3A 13/4 1 x `{`2.�. x. 70 f0 1-1/2 ....!'F... 5C 3014 1 33 50 100 0 5 4 ... btu 7 :35L a' 7 `k 1 '01.86 2-1/2 35C 3024 1.70 18 36 1.6 Fig. 35BC3 Beam Clamp 0=i Packing : 'Vsg t. _��" P Size Part Number'. ��� INS �� �. I� Inner ':`� Masfe�r Al ■ 3/8 35BC3003 0 75 100 200 , 0 3 r5 9,1 5 we NEA Ad G .1 .: 3B01 r, 7 _ f} 8(3 ,x' - .r 1 .. 0 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com �V � k Warrantyand 1�1tat10ri� b��Lia1�a SMITH-COOPER INTERNATIONAL(SCI)warrants to its initial purchaser only,that its products which are delivered to this initial purchaser will be of the kind described in the order or price list and will be free of defects in workmanship or material for a period of five years from the date of delivery to our initial purchaser. Should any failure to conform to this warranty appear within five years after the date of the initial delivery to our initial purchaser,SCI will,upon written notification thereof and substantiation that the goods have been stored,installed,maintained and operated in accor- dance with recognized engineering and piping practices and industry standards,correct such defects by suitable repair or replacement (which alternative shall be at the discretion of SCI)of product at SCI's own expense upon return of the defective part to SCI. In the event that SCI elects to replace the defective product,SCI shall pay up to$50 per defective product for total cost of replacement. In the event of multiple claims,such payment shall be no greater than$1,000 for each installation project. This warranty applies only during normal use that meets the above referenced conditions of installation and operation and is absolutely void if the product has been damaged after purchase or if it has been misused,repaired,altered or modified in any manner whatsoever. SCI shall not warranty any of its products if any portion of the product including without limitation,any component,gasket,housing or bolt has been modified,altered,remanufactured or replaced in any manner by any customer,user of the product or third party. Correction of non-conformities,in the manner and for the period of time provided above,shall constitute fulfillment of all liabilities of SCI to our initial purchaser,with respect to the goods,whether based on contract,negligence,strict tort,or otherwise. It is the intention of SCI that no warranty of any kind,whether expressed or implied shall pass through our initial purchaser to any other person or corpora- tion. No returns will be allowed unless prior written permission of SCI is first obtained. Buyers shall be responsible for all costs of transporta- tion as well as a restocking charge. This warranty is exclusively for the benefit of the initial purchaser of this product from SCI and,except to the extent prohibited by ap- plicable law,the foregoing warranty is in lieu of all other warranties,express or implied,including but not limited to warranties of fitness or merchantability. LIMITATIONS OF LIABILITY:SCI shall not under any circumstances be liable for special or consequential damages such as,but not limited to damage to loss of other property or equipment,loss of profits or revenue,cost of capital,cost of purchased or replacement goods, claims of customers of our initial purchaser,any labor cost for repair or replacement of the product or damage caused by the product. The remedies of our initial purchaser,and all others,set forth herein are exclusive,and the liability of SCI with respect to same shall not, except as expressly provided herein,exceed the price of the SCI products on which such liability is based. ©2010 Smith-Cooper International® 84 SmI nr4 'FOIX,EFHRIt.IrS0001%66(100076. •F i43,t13)98904 45& •wwwwsmi hopopeonam 84 . T FireLock EZ® Rigid Coupling 4tauiicr Style 009N 10.64 Material Specifications: /.. Housing: • Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. PATENTED Housing Coating: Approvals/Listings: 0 Orange enamel (North America, Asia Pacific) 0 Red enamel (Europe) c ri,us ® 1LPCB 030 Optional: Hot dipped galvanized LISTED See Victaulic Publication 10.01 for more details. Gasket: Grade "E" EPDM (Type A) Product Description: FireLock EZ products have been Listed by Underwriters p �- The FireLock EZ Style 009N Installation ReadyT" Laboratories Inc., Underwriters Laboratories of Canada Limited,and Approved by Factory Mutual Research for Rigid Coupling is for use in the fire protection market. wet and dry(oil free air)sprinkler services within the rated The coupling's unique design eliminates loose parts, working pressure. promotes consistent installation and provides substantial Bolts/Nuts: gains in productivity. IMPORTANT Zinc electroplated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and FireLock EZ Style 009N couplings are recommended for physical requirements of ASTM A-183. use ONLY on fire protection systems. Job/Owner Engineer System No. Spec Section Location Paragraph Contractor Approved Submitted By I Date Date - victaulic.com I Couplings I Rigid I Style 009N I Publication 10.64 10.64 7072 Rev F Updated 03/2014 ©2014 Victaulic Company.All rights reserved. 1 4tauiic victaulic.com I Couplings I Rigid I Style 009N I Publication 10.64 Listings/Approvals 1 The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Nominal Size cULus FM Vds LPCB Sch.5 Sch.10 Sch.40 Sch.5 Sch.10 Sch.40 _ inches psi I psi psi psi psi psi psi I psi mm kPa kPa kPa kPa kPa ( kPa kPa kPa 11/4 232 365 365 175 363 363 3 5 365 32 1600 2517 2517 1205 2502 2502 51 77 2517 11/2 232 365 365 175 363 363 365 365 40 1600 2517 2517 1205 2502 2502 2517 2517 2 363 365 65 175 363 i 363 365 365 50 2502 2517 2517 1205 2502 2502 2517 2517 2365 ..__._ N/A 365 175 363 363 365 365 65 2517 2517 1205 2502 { 2502 2517 2517 3652 76.1 mm N/A 2517 N/A N/A 3633 N/A 365 365 ! 2502 I 2517 2517 365 3 N/A 365 175 363 363 365 365 2517 2517 1205 2502 2502 2517 2517 365365 175 100 N/A 363 363 365 365 2517 2517 1205 2502 2502 2517 2517 108.0 mm N/A N/A N/A N/A 363 363 N/A N/A 2502 I 2502 5 290365 125 N/A N/A 363 3632502 N/A N/A 2000 2517 __. 133.0 mm Refer to Submittal 10.61 139.7 mm Refer to Submittal 10.61 165.1 mm Refer to Submittal 10.61 — — A 6 290 1 365 363 363 150 N/A 2000 2517 N/A 2502 2502 N/A N/A 8 290 365 200 N/A 2000 2517 N/A 363 363 N/A N/A — --- 1__... 2502 2502 Listed/Approved for wet and dry pipe systems(> 40°F/-40°C)for continuous use in freezing conditions,use of silicone gaskets is recommended. Please refer to the Victaulic Installation Manual(I-009N/009H)for details concerning when supplemental lubrication is required. 2 cULus listed for DIN 2458 2.6 mmm pipe wall. 3 FM approved for BS 1387 Medium 3.6 mm pipe wall. Speciality Pipe Pipe Size Pressure Rating Pipe I Size Pressure Rating Pipe Size Pressure Rating cULus FM cULus FM cULus FM Sch. inches psi psi Sch. inches psi psi Sch. inches psi psi kPa kPa kPa kPa kPa kPa 300 365 300 365 BLT 1'/a 2 2068 2517 EZT 1'/a 2 2068 2517 MT 1'/a-2 300 365 2068 2517 DF 1'/a-4 300 365 5 FF 1 Y4–4 300 365 � 365 2068 2517 2068 2517 MLT 1 /a–2 N/A f 2517 DT 300 365 11/4–2 2068 2517 FLF I 1 Y4–4 N/A 365 ST 1 Y4–2 N/A 365 2517 EF 1 Y4–4 5 175 FLT 1'/4 2 N/A 365 1 365 1206 1206 4 2517 STF 1 /4–4 N/A 2517 EL 11/4–2 300 365 FLTL 1 Y4–2 N/A 365 TF 2Y–4 N/A 365 2068 2517 2517 2517 300 65 ET40 1 Y4–2 365 GL 1 Y4–2 300 365 � 300 5 2068 2517 I I 2068 2517 WLS 1/4–2 2068 2517 EZF 3–4 300 2068 251 MF 300 1 Y4–4 I 2068 5365 17 WST 11/4–2 N/A 365 2517 XL 1Y4-2 300 365 2068 2517 10.64 7072 Rev F Updated 03/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 2 ✓Ctaulic° victaulic.com I Couplings I Rigid I Style 009N I Publication 10.64 Style 009N Dimensions: Y rZ-1 < YY rzl _ila/ N i$ is'// - R. Style 009N Pre-Assembled Style 009N Joint Assembled (Push On Condition) Dimensions Pre-assebled Approx. Actual Maximum Maximum Allow. (Push On Condition) Joint Assembled Weight Nominal Outside Working End Pipe End - Size Diameter Pressure' Load' Separation2 Bolt/Nut3 I X Y X Y Z Each inches inches psi lbs. inches (No.)size inches inches inches inches inches lbs. 1.660 . mm mm kPa N mm inches mm mm mm mm mm kg 1'/a1. _ --- 1 660 365 790 0.10 2-3/a x 2 3.10 4.90 2.70 4.90 1.92 3242.4 2517 3514 2.54 M 10 x 2 79 124 69 124 49 0.7 11/2 _- 'h 1.900 365 1035 0.10 2-3/8x 2 3.30 5.10 3.00 5.10 1.92 1.5 40 48.3 2517 4604 2.54 M 10 x 2 84 129 76 129 49 0.7 2 2.375 365 1616 0.12 2-3/8 x 2 3.90 5.60 3.50 5.60 1.95 1.9 50 60.3 2517 7193 3.05 M-10x 2 99 142 89 142 50 0.9 2 Yz 2.875 365 2370 0.12 2 3/8 x 21/2 4.50 6.10 4.00 6.10 1.95 2.1 65 73.0 2517 10542 3.05 M 10x21/2 114 155 102 155 50 1.0 1.0 76.1 mm 3.000 365 2580 0.12 2-3/8x 2'/z 4.56 6.00 4.05 6.06 1.94 2.1 76.1 2517 11476 3.05 M-10x2/ 115.7 152.5 102.8 153.9 49.2 1.0 3 3.500 365 3512 0.12 2-3/8 x 21/2 5.10 6.70 4.60 6.70 1.95 80 88.9 2517 15622 3.05 M-10 x 21/2 129 170 117 170 50 1.0 4 4.500 365 5805 0.17 2-3/8x 21/2 5.95 7.80 5.54 7.47 2.14 2.9 100 114.3 2517 25822 4.32 M 10 x 21/2 151 199 141 190 55 1.3 i 4.250 365 5175 0.17 2_3/e x 2'/z 5.56 7.39 5.28 7.36 108.0 mm 141 1.88 134 187 54 1.4 108.0 2517 23020 4.318 5 5.563 365 5178 0.177.19 9.25 6.7 9.11 2.19 2 1/2 x 3 L 235 170 231 56 183 1 2.3 125 1413 2000 23033 4.318 __._..._. _._._...___._.-. 133.0 mm Refer to Submittal 10.61 139.7 mm Refer to Submittal 10.61 165.1 mm Refer to Submittal 10.61 6 6.625 365 9997 0.172-1/2 x 3'/a 8.32 10.29 7.82 10.13 150 168.3 2000 44469 4.318 211 261 199 257 55 2.7 8 8.625 365 13730 0.172-5/8 x 4 10.89 13.31 10.22 13.1 200 219.1 1620 61074 4.318 277 338 260 333 64 5.2 1 Working Pressure and End Load are total,from all internal and external loads,based on standard weight(ANSI)steel pipe,standard roll or cut grooved in accordance with Victaulic specifications.See page 1 of this document for Listed/Approved ratings on other pipe.WARNING:FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 1'/z times the figures shown in the chart on page 1,specific to pipe schedule and size. 2 The allowable pipe separation dimension shown is for system layout purposes only.FireLock EZ couplings are considered rigid connections and will not accommodate expansion or contraction of the piping system. 3 Number of bolts required equals number of housing segments. General Notes: NOTE:When assembling FireLock EZ couplings onto end caps,take additional care to make certain the end cap is fully seated against the gasket end stop.For FireLock EZ Style 009N couplings,use FireLock No.006 end caps containing the"EZ"marking on the inside face or No.60 end caps containing the"QV EZ" marking on the inside face.Non-Victaulic end cap products shall not be used with Style 009N couplings.IMPORTANT:Gaskets intended for the Style 009 or Style 009V couplings cannot be used with the Style 009N coupling.There is no interchanging of gaskets or housings between coupling styles. Use Of Flushseal Gaskets For Dry Pipe Systems NOTE:FireLock EZ couplings are supplied with FireLock EZ Grade"E"Type A gaskets.These gaskets include an integral pipe stop,that once installed provides the similiar benefits as a FlushSeal gasket for dry pipe systems.It should be noted that standard Victaulic FlushSeal gaskets are not compatible and cannot be used with the FireLock EZ couplings. Installation Note Reference should always be made to the I-100 Victaulic Field Installation Handbook for This product shall be manufactured by Victaulic or to Victaulic specifications.All products the product you are installing.Handbooks are included with each shipment of Victaulic to be installed in accordance with current Victaulic installation/assembly instructions. products for complete installation and assembly data,and are available in PDF format Victaulic reserves the right to change product specifications,designs and standard on our website at www.victaulic.corn. equipment without notice and without incurring obligations. - Warranty Trademarks Refer to the Warranty section of the current Price List or contact Victaulic for details. Victaulic,FireLock EZ,and Installation-Ready are registered trademarks of Victaulic Company. 10.64 7072 Rev F Updated 03/2014 ©2014 Victaulic Company.All rights reserved. \iCtaLJlIC victaulic.com 3 irj.,:ti,,:i:ozT.7..::,,!,F'kf.:cf=':'i,RRVTP-,,IF,Eg-J:.q,PP4K:q,RPPN-P-Y5JikrizE,!,4,j,';I, ::.7-47rrz,.7tk,,-7-t?°N;t7-7:!,:':.,..:...:'i::-;..:v?;,EA',iv:R.t74rgPc.rt;!4:i7.':!r:...-;':-:-:,•';'5:g.,Yki„.. FireLock® Fittings „., „ i VMIPO See Victaulic publication 10.01 for details • it FireLock®products comprise a unique system specifically designed for fire protection *44114' ilellittall."4"' services. FireLock full-flow elbows and tees feature CAD-developed, hydrodynamic design,affording a shorter center-to-end dimension than standard fittings.A noticeable bulge allows the water to make a smoother turn to maintain similar flow characteristics as standard full flow fittings. FireLock fittings are designed for use exclusively with Victaulic IPS-sized couplings that have been Listed or Approved for Fire Protection Services. Use of other couplings or flange adapters may result in bolt pad interference. Victaulic FireLock fittings pressure ratings conform to the ratings of Victaulic FireLock EZ® Style 009H couplings. MATERIAL SPECIFICATIONS Fitting: Ductile iron conforming to ASTM A-536,grade 65-45-12. Fitting Coating: • Orange enamel. • Red Enamel in EMEA-I. • Optional: Hot dipped galvanized. JOB/OWNER CONTRACTOR ENGINEER 91114 System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2011 VICTAULIC COMPANY.ALL RIGHTS RESERVED. CtaUI1C® REV _1 10.01 1 IPS CARBON STEEL PIPE-FIRE PROTECTION PRODUCTS I U•U3 i - Fittings DIMENSIONS N-ctoE+l -4 I to o_ ctoE -0 g__7 7 to E �i_ �r-1, Ito � I E NO.001 NO.003 NO.002 NO.006 No.001 No.003 No.002 No.006 Size 90 Elbow 45 Elbow Straight Tee Cap ma. '. pts I ActualApprox. p � ° 0 <Netacf� ., Weight e` Weight Size Outside Diameter C to E Weight'Eacti �+ s 'lnehes a Andres" inches n s. Lbs Indies M 2't �., mm 3..� ` _�. Y.' g :". mm :war."' ''~ '� 0.8 03 1'/a 1.6 - - - - 21 0.1 32 42.44 - _ - - 0.82 0.4 - 40 483 1.900 - - - 21 • 0.2 40 2 2.375 2.75 17 2.00 1.8 275 2.4 0.88 0.6 50 60.3 70 0.8 51 0.8 70 1.1 22 03 21/2 2875 3.00 3.1 2.25 22 3.00 3.6 0.88 1.0 65 73.076 14 57 1.0 76 1.6 22 05 ._ 76.1 mm 3.000 3.00 330 2.25 2.4 - - 76.1 76 15 57 1.1 3 ........3.500 338 4.0 250 3.1 338 5.3 0.88 1.2 80 88.9 86 1.8 64 14 86 2.4 22 05 4.250 4.00 57 3.00 5.1 4.00 7.5 0$mm 108.0102 2.6 76 23 102 3.4 4 4.500 4.00 6.7 3.00 5.6 4.00 87 1.00 2.4 00 14.3102 3.0 76 2.5 102 3.9 25 1.1 5 5.563 4.88 12.6 325 83 4.88 157 1.00 4.1 125 141.3 , 124 57 83 3.8 124 71 25 1.9 159mm 6.250 5.50 12.6 3.50 9.2 5.50 179 158.8140 57 89 4.2 140 8.0 6___. 6.625 5.50 18.3 350 11.7 5.50 227 1.00 • 59 150 168.3140 8.3 89 5.3 140 10.3 25 2.7 8 8.625 • 6.81 25.5 4.25 . 20.4 6.94 38.7 1.13 12.7 200 219.1 173 11.6 108 9.3 176 17.6 29 5.8 www.victaulic.com �CtaulL VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2011 VICTAULIC COMPANY.ALL RIGHTS RESERVED. REV .1 10.03 2 IPS CARBON STEEL. PPE-FIRE PROTECTION PRODUCTS • C . .: Fittings - FLOW DATA Size Frictional Resistance Equivalent Feet/meters of Straight Pipe r Actual. e poTinal Ouksid bwc DU3 "ate SiInclze 3ies Tetorn mot 90°*Eltrow ter t No. se eo No 001 No 003 I Si eh It 1'/4 1.660 fhn. _ 32 42.4 - - - 11/2 1.900 40 48.3 - - 2 2.375 3.5 1.8 8.5 3.5 50_. 60.3 1.1 0.5 2.6 1.1 21/2 2.875 4.3 2.2 10.8 4.3 65 73.0 1.3 0.7 3.3 1.3 76.1 mm 3.07000.1 4.5 2.3 11.0 4.5 0.7 3.4 1.4 3 3.500 5.0 2.6 13.0 5.0 80 88.9 1.5 0.8 4.0 1.5 108 mm 4.250 6.4 3.2 15.3 6.4 108.0 2.0 0.9 4.7 2.0 4 4.500 6.8 3.4 16.0 6.8 100 114.3 21 1.0 4.9 2.1 5 5.563 8.5 4.2 21.0 8.5 125 141.3 2.6 1.3 6.4 2.6 159 mm 6.250 9,4 4.9 25.0 9.6 158.8 2.9 1.5 7.6 2.9 6 6.625 10.0 5.0 25.0 10.0 150 168.3 3.0 1.5 7.6 3.0 8 8.625 13.0 5.0 33.0 13.0 200 219.1 4.0 1.5 101 4.0 t The flow data listed is based upon the pressure drop of Schedule 40 pipe. www.victaulic.com VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2011 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ✓ctaUI1C® RFV I 10.03 3 FireLock® Fittings GENERAL NOTES NOTE:When assembling FireLock EZ couplings onto end caps,take additional care to make certain = the end cap is fully seated against the gasket end stop. For FireLock EZ Style 009/009V/009H couplings, use FireLock No.006 end caps containing the"EZ" marking on the inside face or No.60 end caps containing the"QV EZ" marking on the inside face. Non-Victaulic end cap products shall _ not be used with Style 009/009V/009H couplings. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. For complete contact information,visit www.victaulic.com 10.03 1539 REV J UPDATED 8/2011 IctaUIiC VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2011 VICTAULIC COMPANY.ALL RIGHTS RESERVED. R6 SEI � PE �o41/I�P C i • Flexible Coupling (vds) LPCB SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS VNIIPO STYLE 75 Style 75 is available where moderate pressures are expected or weight considerations are a factor. Up to 50%lighter in weight than the Style 77, the Style 75 coupling is recommended for service up to 500 psi/3450 kPa depending on size. Housings are cast in two identical pieces in all sizes. Hot-dip galvanized and special coatings are available for all sizes. Exaggerated for clarity MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536,grade 65-45-12. Ductile iron conforming to ASTM A-395,grade 65-45-15, is available upon special request. Housing Coating: Orange enamel. • Optional: Hot dipped galvanized and others. Gasket: (specify choice*) • Grade"E"EPDM EPDM (Green color code).Temperature range—30°F to+230°F/-34°C to+110°C. Recommended for hot water service within the specified temperature range plus a variety of dilute acids,oil-free air and many chemical services. UL classified in accordance with ANSI/NSF 61 for cold+86°F/+30°C and hot+180°F/+82°C potable water service. NOT RECOMMENDED FOR PETROLEUM SERVICES. • Grade"T"nitrile Nitrile(Orange color code). Temperature range—20°F to+180°F/-29°C to+82°C. Recommended for petroleum products,air with oil vapors,vegetable and mineral oils within the specified temperature range;except hot,dry air over+140°F/+60°C and water over +150°F/+66°C. NOT RECOMMENDED FOR HOT WATER SERVICES. * Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Bolts/Nuts: Heat-treated plated carbon steel,trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2008 VICTAULIC COMPANY.ALL RIGHTS RESERVED.. _.ctatik c REV _I 0E05 1 CARBON STEEL PIPE GROOVED COUPLINGS V O.V3 Flexible. € STYLE 75 DIMENSIONS Max.Work Allow.Pipe Bolt/Nut@ Approx ;, Size Pressure" Max.End Load" End Sep.t Deflect.Fr.Cit No Size Dimensions Inches/mm Wgt Each la S na fam r ger Inches n¢hes psi Lbses: & s 1 z , 'x 'matte kr N rnm" 1; nFf m 1 1.315 500 25 33.4 3450 3025 0-1680 0-0.06 0.57 2 38 4.27 77 3 2°-43' 2-3/ax2 .6 48 61 08 45 0.6 1'/a 1.660 500 1080 0-0.06 0.45 2.68 4.61 1.77 1.4 32 42.2 3450 4805 0-1.6 2°-10' 38 2-3/852 68 117 45 0.6 1/z 900 500 420 0 0.06 008.43320 .40 2.91 4.82 1.77 5 1°-56' 2-3/2x2 40 483 3450 6320 0-1.6 33 74 22 45 0.6 2 _.. 2.375 500 2.215 0-0.06 0.32 3.43 5.22 1.88 1.7 1°-31' 2-3/ax2 50 603 3450 9860 0 1.6 26 87 33 48 0.8 2Yz 2.875 500 3.245 0 0.06 02.22226 3.88 5.68 1.88 1.9 1°-15' 2-3/2x2 65 73.0 3450 14440 0-1.6 _.. 98 144 48 0.9 76.1 mm# 3.000 500 3.535 0 0.06 0.26 4.00 5.90 88 1.9 76.1 3450 15730 0-1.6 1 -12 2 3/a x 2 102 50 48 0.9 3 3.500 500 4.800 0-0.06 0.22 4.50 7.00 _ 1.88 2.9 1°-2' 2-Yzx23/a 4 178 48 3 80 88.9 3450 21360 0-1.6 8 3 Yz 4.000 500 6300 00--0i066 0°-54' 0.19 2-Yz x 23/4' 5 00 7.50 1.88 2.9 90 101.6 3450 28035 16 27 91 48 3 4 4.500 500 7.950 0-0.13 1°-36' 0.34 2-'h x 2 Y. 5.80 8.03 2.13 4.1 100 114.3 3450 35380 0-3.2 28 147 204 54 1.9 108.Omm 4.250 450 6.380 00--03123 0.35 5.55 7.79 213 3.7 108.0 3100 28395 . 1° 41' 29 2-12 x 70.0 141 98 54 1.7 4 Yz 5.000 450 8.820 0-0.13 0.25 6.13 9.43 2.13 5.5 -26' 2-s/ax3Ya 120 127.0 3100 39250 0-3.2 21 156 240 54 25 5 _. 5.563 450 10935 0 0.13 0.27 6.88 0.07 2.13 5.8 1°-18' 2-s/ax3Ya 125 141.3 3100 48660 0-3.2 23 75 256 54 2.6 33.O mm 5.250 450 9.735 0-0.13 0.28 6116565 923387 2.13 6.0 1°-21' 2-16x82.5 133.0 3100 43325 0-3.2 24 66 238 54 2.7 139.7 mm# 5.500 450 10.665 0-0.13 0.28 6.80 924549 2.13 6.3 39.7 3100 47460 0-3.2 1°-18' 24 2 s/a x 3 Ya 73 244 54 2 9 152.4 mm 6.000 450 2.735 0-0.13 0.21 7.38 10.48 1.88 6.2 11°-12' 2-5/ax3'/a 152.4 3100 56670 0-3.2 18 87 266 48 2.8 6 6.625 450 15.525085 00 0.13 1` 5 8 20.23 2-5/a x 3'/a 8. 11.07 25143 7.0 150 168.3 3100 69 -3.2 0300 281 5413 3.2 Continued on page 3. *t @ t Refer to notes on page 3. 1�:�� / i:.1 IF 11 ri Iii I I .�11. =� 1111 www.victaulic.com jictaulic' VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2008 VICTAULIC COMPANY.ALL RIGHTS RESERVED.. 06,05 2 REV .1 CARBON STEEL PIPE-GROOVED COUPLINGS UO.V 3 t ; Flexible Coupling STYLE 75 DIMENSIONS Max.Work Allow Pipe Bolt/Nut@ Size Pressure Max End Load End Se t Approx. P Deflect Fr C�i No Size Dimensions Inches/mm Wgt Each Nominal Outside f� > Per Inches„ inn In/FL rfinmm Inches hey tag Pipe ° xa �s N m Deg. s, mm/Fn Ines „ r a z .ti 6.250 450 13.800 0-0.13 159.0 mm 159.0 3100 61405 0-3.2 1° 9' 0.24 2-16x82.5 " 7.63 0.49 2.13 6.8 20 194 266 54 3.1 203.2 mm# 8.000 450 22.635 0-0.13 0.16 9.72 13.33 2.31 2.6 203.2 3100 100725 0-3.2 0°-54' 13 2-3/4x 41/4247 339 58 5.7 8 8.625 450 26.280 0-0.130.18 10.34 13.97 232 12.4 200 219.1 3100 116945 0-3.2 0° 50' 4 2 3/a x 4%a 263 355 59 5.6 254.0 mm# 10.000 350 27.500 0-0.13 0.15 1216 .81 2.53 20.8 254.0 2400 122375 0-3.2 0 43 2 /s x S%z 309 15402 64 9.4 304.8 mm# 12.000 350 39.500 0-0.13 0.13 14.16 17.69 2.53 23.6 304.8 2400 175775 0-3.2 0°-36' 9 2-'/e x S Yz 360 449 64 10.7 * Working Pressure and End Load are total,from all internal and external loads,based on standard weight(ANSI)steel pipe,standard roll or cut grooved in accordance with Victaulic specifications.Contact Victaulic for performance on other pipe. WARNING:FOR ONE TIME FIELD TEST ONLY,the Maximum Joint Working Pressure may be increased to 1 1/2 times the figures shown. t Allowable Pipe End Separation and Deflection figures show the maximum nominal range of movement available at each joint for standard roll grooved pipe.Figures for standard cut grooved pipe may be doubled.These figures are maximums;for design and installation purposes these figures should be reduced by:50%for 3/a-31/2"/20-90mm;25%for 4'%100 mm and larger. @ Number of bolts required equals number of housing segments. Metric thread size bolts are available(color coded gold)for all coupling sizes upon request.Contact Victaulic for details. 1 Y 14-Z 11 lilt jikff Ell - %........., - _J 1 Ilrl r www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2008 VICTAULIC COMPANY.ALL RIGHTS RESERVED.. ICt'dUI1C® Pr I _ .., .,... .. n6 n5 r-lexible Coupling STYLE 75 WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data,and are available in PDF format on our website at www.victaulic.com. III 111111111 111111111111 1111 1111 111E1 111 WCAS-7BDNAR For complete contact information,visit www.victaulic.com 06.05 1470 REV J UPDATED 1/2008 IctauIi�. VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2008 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 06.05 R .N STEL P U 9 • • • Reducing Coupling ® VdS LPCB SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS vN"P° STYLE 750 The Style 750 Reducing Coupling permits direct reduction on the piping run. Designed to replace two couplings and a reducing fitting,the Style 750 features a special reducing gasket for pressure responsive sealing.A steel washer which prevents telescoping of the smaller pipe inside the larger pipe during vertical systems assembly is available upon - request. Exaggerated for clarity MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536,grade 65-45-12. Ductile iron conforming to ASTM A-395,grade 65-45-15, is available upon special request. Housing Coating: Orange enamel • Optional: Hot dipped galvanized and others Gasket: (Specify choice*): • Grade"E"EPDM (All other sizes) EPDM (Green color code).Temperature range—30°F to+230°F/-34°C to+110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids,oil-free air and many chemical services. UL classified in accordance with ANSI/NSF 61 for cold+86°F/+30°C and hot+180°F/+82°C potable water service. NOT RECOMMENDED FOR PETROLEUM SERVICES. • Grade"T"nitrile Nitrile(Orange color code).Temperature range—20°F to+180°F/-29°C to+82°C. Recommended for petroleum products,air with oil vapors,vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over+150°F/+66°C or for hot dry air over+140°F/+60°C. * Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. • Optional:Assembly Washer:Galvanized, carbon steel Bolts/Nuts: Heat-treated plated carbon steel,trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. �CtaulIC. RFV J MLR i CARBON STEEL PIPE-GROOVED COUPLINGS UO.UO , Reducing lin STYLE 750 DIMENSIONS Max.Work Allow.Pipe Bolt/Nut@ Approx. Size Pressure Max End Load End Sep.t Deflect.Fr.Co No Size Dimensions Inches/mm Wgsize t Each - No 1 , p r pi e i inches/1 m ,. tictla 4 .mm :t° ,. fmmfm , Inches X .,,: V Z. ke..x 2 x 1 350 500 0-0.07 0° 57 0.20 2-3/s x 2 3.38 5.28 1.88 27 85 134 48 1.2 50 25 2410 2225 0-1.8 17 11/2 350 1000 0-0.070.20 2-3/ax2 338 5.28 188 2.0 40 2410 4450 0 1.8 0 87, 17 85 134 48 1.0 21/2 2 500 2215 0-0.070.16 2-'/ax2 400 593 1.88 3.1 x 65 50 > 3450 9850 0-1.8 0 -47 14 102 151 48 1A 76.1 mm x 2 350 1550 0-0.07 0.16 438 6.63 1.88 4.6 50 2410 6900 0 1.8 0°-47 14 2-/2x2/4 111 168 48 2.1 3 2 350 1550 0-0.07 0°-39 0.13 2-'/z x 23/4 4.75 7.13 1.88 4.9 80 x 50 2410 6900 0-1.8 11 121 181 48 22 21/4 500 3250 0-0.070.13 2-Yz x 2 3/a 4.75 7.13 1.88 43 0 -39° ' 65 3450 , 14460 0-1.8 11 21 181 48 2.0 350 2475 0-0.07 0.13 2-Yz x 2 3/4 4.75 7.13 1 88 4.2 88.9 mm x 76.1 mm ' 0°-39' 11 21 81 48 9 2410 11010 0 1.8 4 2 350 1550 0 0.131° 19 0.28 2-5/9x3'/a 6.25 8.90 225 8.1 100 x 50 2410 6900 0 3.2 25 159 226 57 3.7 21/2 350 2275 0-0.13 6.25 8 90 225 8.6 1° 19 O2 8 2 -5/ax3Y4 159 226 57 3.9 65 2410 10125 , 0 3.2 3 500 4810 0-0.130.28 2-5/a x 3'/a 6.00 890 225 6.7 80 3450 21400 0 3.2 1° 19' 25 152 226 57 3.0 350 2475 0-0.130.28 2-5/4x3'/ 625 8.90 2.25 6.9 114.3 mm x 76.1 mm 1°-19' 25 59 226 57 3.1 2410 11014 0 3.2 7.18 10.70 213 11.2 5 4 350 5565 0 0.13 1°-3' 0 9 2 34 x 4'/a 182 272 54 5.1 125 x 100 2410 24765 0 3.2 6 4 350 5565 0 0.13 0.18 2-3/a x 4Ya 8.63 11.90 225 167 0°-52 181 302 57 7.6 150 x 100 2410 24765 0 3.2 5 5 350 8500 0-0.13 8.31 1190 225 129 0° 52 0.18 2-/4x4/4 125 2410 37825 0-3.2 15 211 302 57 59 165.1 mm x 4 350 5565 0-0.130.19 8.63 11.90 225 15.2 0°-55' 16 2-/4x4/4 219 302 57 6.9 100 2410 24765 0 3.2 - 8 6 350 12060 0 0.13 0°-38' 013 2-'/e x 5 10.81 14.88 2.50 22.4 x 200 150 2410 53645 0 3.2 11 275 378 64 10.2 350 11610 0-0.130.13 2-7/sx5 10.75 14.88 250 23.2 2410 51645 219.1 mm x 165.1 mm 0 -38 0 3.2 11 273 378 64 10.5 113.12 17.26 2.62 31.4 0 8 350 20450 0 0.13 0° 25 0'9 2-1 x 5'/z 333 438 67 14.2 273 x 219.1 2410 90970 0-3.2 8 Style 750 Reducing couplings should not be used with end caps(#60)in systems where a vacuum may be developed.Contact Victaulic for details. *Working Pressure and End Load are total,from all internal and external loads,based on standard weight(ANSI)steel pipe,standard roll or cut grooved in accordance with Victaulic specifications.Contact Victaulic for performance on other pipe.Maximum working pressure rating based on larger pipe size. Maximum End Load rating based on smaller pipe size.WARNING:FOR ONE TIME FIELD TEST ONLY,the Maximum Joint Working Pressure may be increased to 1'/z times the figures shown. t Allowable Pipe End Separation and Deflection figures show the maximum nominal range of movement available at each joint for standard roll grooved pipe.Figures for standard cut grooved pipe may be doubled.These figures are maximums;for design and installation purposes these figures should be reduced by:50%for 34-31/2'720-90 mm;25%for 47100 mm and larger. @ Number of bolts required equals number of housing segments. Metric thread size bolts are available(color coded gold)for all coupling sizes upon request.Contact Victaulic for details. WARNING:Depressurize and drain the piping system before attempting to install,remove,or adjust any Victaulic piping products. 44_Z- iiiiY 1 Y > r-Z1 Ijliii �:.e/.‘,m,„m„..!,i �.:� Ir 11 ,i. ur i.,r I ��l "l'` �` 1111li www.victaulic.com \iCtaulac VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. FtEV .1 06.OR 7 CARBON STEEL PIPE-GROOVED COUPLINGS VO.VO f .educing Coupling STYLE 750 FLOW DATA HEAD LOSS The head loss across Style 750 Reducing coupling is very small and is essentially the same as for standard short body reducing pipe fittings. Equivalent lengths of standard weight steel pipe are shown in the tables.All data is based on water flowing at ambient temperature. FLOW REDUCING FLOW EXPANDING Equiv.Pipe Equiv.Pipe Size Length Size Length Nominal Nominal Size Sm,Dia Size S Dia. .s m ches/mfeet/m Inches/1nm - V Feetim 2 1 5.9 12 2.7 50 x 25 1.8 25 x 50 0.8 1/ 2.0 11/2 2 1.9 40 0.6 40 x 50 0.6 21/2 2 1.9 22/ 1.0 65 x 50 0.6 50 x 65 0.3 1.9 76.1 mm x 50 00.6 76.1 mm 1.0 0.3 3 2 5.5 3 3.5 80 x 50 1.7 80 1.1 21/2 3.8 4 3.0 65 1.2 100 0.9 88.9 mm x 76.1mm 3.8 21/23 2.5 L2 65 x 80 0.8 4 2 6.0 4 3.0 100 x 50 1.8 100 0.9 2Y 6.0 2.5 65 1.8 76.1 mm x 88.9mm 0.8 3 6.0 3.0 80 1.8 114.3mm 0.9 114.3 mm x 76.1mm 6.0 3 4 2.5 1.880 x 100 0.8 5 4 3.0 4 5 3.3 125 x 100 0.9 100 x 125 1.0 6 4 6.0 6 4.6 150 x 100 1.8 150 1.4 5 4.5 4.6 125 1.4 65.1 mm 1.4 165.1mm x 4 6.0 5 6 2.3 100 1.8 125 x 150 0.7 8 6 7.3 6 8 6.0 X ._. 200 150 2.2 150 x 200 1.8 219.1mm x 165.1 mm 73 165.1mm x 219.1 mm 5.4 2.23 1.65 10 8 8.7 810 6.3 273 x 219.1 2.65 219.1 x 273 19.2 www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ✓ctaUlic I?FV I or,nR • Reducing p STYLE 750 INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data,and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. For complete contact information,visit www.victaulic.com 06.08 1536 REV J UPDATED 08/2012 IctauI1c® VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 06.0g Product Information M„T, FS-ONE High Performance Intumescent ; Firestop Sealant . ,.. w. - Product description - ■ Intumescent(expands when exposed to fire)firestop sealant that ., helps protect combustible and non-combustible penetrations for up to 4 hours fire rating ... �� Product features . ::,,,..i;,,,,,,,,::. el6 ::: ■ Smoke,gas and water resistant after material has cured■ Contains no halogen,solvents or asbestos y ■ High fire rating propertiesr a ■ Water based,easy to clean :• ■ Protects most typical ical firestop penetration applications ■ Paintable Technical Data* FS.-ONE' IISingle component systems available Chemical basis Water-based intumescent acrylic IIIMeets LEEDTM requirements for indoor environmental quality credit dispersion 4.1 Low Emitting Materials,Sealants and Adhesives and 4.2 Paints Color Red and Coatings Application temperature 40°F to 104°F(5°C to 40°C) Areas of application Skin forming time Approx.20-30 min. • Steel,copper and EMT pipes Curing time Approx.2 mm/3 days Movement capability Approx.5% • Insulated steel and copper pipes Expansion rate(unrestricted) Up to 3-5 times original volume • Cable bundles • Closed or vented plastic I es Temperature resistance(cured) -40°F to 212°F(-40°C to 100°C) p p Surface burning characteristics Flame Spread:0 • HVAC penetrations (ASTM E 84-96) Smoke Development:5 For use with Sound transmission classification 56(Relates to specific construction) (ASTM E 90-99) ■ Concrete,masonry,drywall and wood floor assemblies Approvals • Wall and floor assemblies rated up to 4 hours •California State Fire Marshal- No.4485-1200:108 Examples •City of New York-MEA 326-96-M Vol.IV Tested in accordance with • Sealing around combustible pipe penetrations in fire rated •UL 1479 •ASTM E 814 •ASTM E 84 construction ■ Sealing around non-combustible penetrations in fire rated At 73°F(23°C)and 50%relative humidity construction PS®Fo FOR FILL, USE IINDTOR R CAVITY PENETRATION ® FIRESTOP SYSTEMS SYSTEM COMPATIBLE r• USSEE UL FIRE RESISTANCE DIRECTORY 66Y7 APPROVED Installation instructions for FS-ONE Notice 4. Smoothing of firestop sealant:To complete the •• On materials where oil,plasticizers or solvents may Before handling,read Material Safety Data Sheet seal,tool immediately to give a smooth appearance. bleed i.e.impregnated wood,oil based seals,green • and product label for safe usage and health Excess sealant,prior to curing,can be cleaned away or partially vulcanized rubber information. from adjacent surfaces and tools with water. • • In any penetration other than those specifically Instructions below are general guidelines—always 5. Leave completed seal undisturbed for 48 hours. described in this manual or the test reports refer to the applicable drawing in the UL Fire 6. For maintenance reasons,a penetration seal could Resistance Directory or Hilti Firestop Systems Guide be permanently marked with an identification plate. Storage for complete installation information In such a case,mark the identification plate and Store only in the original packaging in a location Opening fasten it in a visible position next to the seal. protected from moisture at temperatures between 40°F(5°C)and 86°F(30°C) 1. Clean the opening.Surfaces to which FS-ONE will Not for use •be applied should be cleaned of loose debris,dirt, Observe expiration date on the packag • High movement expansion joints oil,moisture,frost and wax.Structures supporting penetrating items must be installed in compliance Underwater with local building and electrical standards. LLI ' ,. -v. % Application of firestop sealant J .mow. alik 2. Install the prescribed backfilling material type and Q � ,,r� ���'" ° � depth to obtain the desired rating(if required).Leave V ?yam *,,'*70/. �. y0111, sufficient depth for applying FS-ONE. ``. �' •- :� ��", � �,� �r< ��� 1.Clean 3. Application of firestop sealant:Apply FS-ONE to the opening. 2.Pack mineral wool. 3.Apply FS-ONE. 4.Smooth 5.Leave completed 6.Fasten kfenti8cation required depth in order to obtain the desired fire rating. (If squired FS-ONE. sealundisturbed for plate(e aqui ed). Make sure FS-ONE contacts all surfaces to provide 48 Hours. maximum adhesion.For application of FS-ONE use a __... .., _ standard caulking gun,foil pack gun,bulk loader and W ' " L a - bulk gun.With FS-ONE buckets,Graco type sealant a -10 L. �y{ ,� pumps may be used.(Contact pump manufacturer for -: proper selection). : = 1.Clean opening. 2.Pack mineral wool. 3.Apply FS-ONE. 4.Smooth 5.Leave completed 6.Fasten identification (It required) FS-ONE. seal undisturbed for plate(if require. 48 hours. Hilti. Outperform. Outlast. Hilti,Inc.(U.S.)1-800-879-8000•www.us.hilti.com•en espanol 1-800-879-5000•Hilti Firestop Systems Guide Material Safety Data Sheet MSDS No.: 259 Revision No.: 010 Revision Date: 08/17/04 Page: 1 of 2 Product name: FS-ONE High Performance Intumescent Firestop Sealant Description: One-part acrylic-based sealant Supplier: Hilti, Inc. P.O.Box 21148,Tulsa,OK 74121 Emergency#(Chem-Trec.): 1 800 424 9300(USA,PR,Virgin Islands,Canada);001 703 527 3887(other countries) INGREDIENTS AND EXPOSURE LIMITS Ingredients: CAS Number: PEL: TLV: STEL: Polyacrylate dispersion Mixture NE NE NE Calcium carbonate 001317-65-3 5 mg/m3(T) 10 mg/m'(r) NE Zinc borate 138265-88-0 NE NE NE Ammonium polyphosphate 068333-79-9 NE NE NE Talc 014807-96-6 20 mppcf 2 mg/m3 NE Expandable graphite 012777-87-6 5 mg/m3(T) 2 mg/m3(r) NE Ethylene glycol 000107-21-1 NE C:100 mg/m3(A) NE Polybutene 009003-29-6 NE NE NE Iron oxide 001309-37-1 10 mg/m3 5 mg/m3 NE Glass filament 065997-17-3 NE 5 mg/ma(T) NE Silicon dioxide 014808-60-7 0.05 mg/m3(T) 0.1 mg/m3(T) NE Water 007732-18-5 NE NE NE Abbreviations: PEL=OSHA Permissible Exposure Limit. TLV=ACGIH Threshold Limit Value. C=Ceiling. STEL=Short Term Exposure Limit. NE=None Established. NA=Not Applicable. (T) indicates"as total dust". (R)indicates"as respirable fraction". (A)indicates"as an aerosol". mppcf=million particles per cubic foot. PHYSICAL DATA Appearance: Red paste. Odor: Odorless. Vapor Density: (air=1) Not determined. Vapor Pressure: 23mbar @ 20C/68F Boiling Point: Not applicable. VOC Content: 75,0 g/L. Evaporation Rate: Not applicable. Solubility in Water: Soluble. Specific Gravity: 1.5 pH: Not determined. FIRE AND EXPLOSION HAZARD DATA Flash Point: Non-flammable. Flammable Limits: Not applicable. Extinguishing Media: Not applicable. Use extinguishing media as appropriate for surrounding fire. Special Fire Fighting Procedures: None known. Use a self-contained breathing apparatus when fighting fires involving chemicals. Unusual Fire and Explosion Hazards:None known. Thermal decomposition products can be formed such as oxides of carbon, sulfur and phosphorous. REACTIVITY DATA Stability: Stable. Hazardous Polymerization: Will not occur. Incompatibility: Strong acids, peroxides,and oxidizing agents. Decomposition Products: Thermal decomposition can yield CO and CO2. Conditions to Avoid: None known. HEALTH HAZARD DATA Known Hazards: None known. Signs and Symptoms of Exposure: Possibly irritating upon contact with the eyes or upon repeated contact with the skin. Medical Conditions Eye and skin conditions. Aggravated by Exposure: Routes of Exposure: Dermal. mtf Hilti Firestop Saving Lives through innovation and education Hilti. Outperform. Outlast. HtItr,Inc.,IU S.)1-800-879-8000•www.us.hllti.com•en espanoi 1-800-879-5000•H Iti(Canada' Corp,1-800-363-4458 www.hiiti.ca IIIIIIIIIEIIEEIIIIIIII MSDS No.: 259 Revision No.: 010 Revision Date: 08/17/04 Page: 2 of 2 Carcinogenicity: IARC classifies crystalline silica(quartz sand)as Group I based upon evidence among workers in industries where there has been long-term and chronic exposure(via inhalation)to silica dust;e.g. mining,quarry,stone crushing,refractory brick and pottery workers. This product does not pose a dust hazard;therefore,this classification is not relevant. Based upon the nature and intended use of this product, it does not pose an increased cancer risk to workers. EMERGENCY AND FIRST AID PROCEDURES Eyes: Immediately flush with plenty of water. Call a physician if symptoms occur. Skin: Immediately wipe off material and wash with soap and water. Material can adhere to the skin. If material has adhered to the skin,use an abrasive containing hand cleaner. If material does not come off, buff with a pumice stone. Inhalation: Move victim to fresh air if discomfort develops. Call a physician if symptoms persist. Ingestion: Seek medical attention. Do not induce vomiting unless directed by a physician.If a large quantity was ingested,give 1 to 2 glasses of water to dilute. Never give anything by mouth to an unconscious person. Other: Referral to a physician is recommended if there is any question about the seriousness of the injury/exposure. CONTROL MEASURES AND PERSONAL PROTECTIVE EQUIPMENT Ventilation: General(natural or mechanically induced fresh air movements). Eye Protection: Not required, however,safety glasses should be worn in most industrial settings. Skin Protection: Avoid skin contact.Cloth gloves are suitable for hand protection. Respiratory Protection: None normally required. Where ventilation is inadequate to control vapors,use a NIOSH approved respirator with organic vapor cartridges. Never enter a confined space without an appropriate air-supplied respirator. PRECAUTIONS FOR SAFE HANDLING AND USE Handling and Storing Precautions: Store in a cool,dry area preferably between 40o and 77o F. Keep from freezing. Do not store in direct sunlight. Avoid contact with the eyes or skin. Practice good hygiene;i.e. always wash thoroughly after handling and before eating or smoking, For industrial use only. Keep out of reach of children. Follow label/use instructions. Spill Procedures: Immediately wipe away spilled material before it hardens. Place in a container for proper disposal in accordance with all applicable local,state,or federal requirements. REGULATORY INFORMATION Hazard Communication: This MSDS has been prepared in accordance with the federal OSHA Hazard Communication Standard 29 CFR 1910.1200, HMIS Codes: Health 1, Flammability 0, Reactivity 0, PPE B DOT Shipping Name: Not regulated. IATA/ICAO Shipping Name: Not regulated. TSCA Inventory Status: Chemical components listed on TSCA inventory.SARA Title III,Section 313:This product contains<3%ethylene glycol(CAS 107-21-1)and<15%zinc borate(re:zinc compounds)which are subject to reporting under Section 313 of SARA Title III(40 CFR Part 372). EPA Waste Code(s): Not regulated by EPA as a hazardous waste. Waste Disposal Methods: Consult with regulatory agencies or your corporate personnel for disposal methods that comply with local,state,and federal safety,health and environmental regulations. CONTACTS Customer Service: 1 800 879 8000 Technical Service: 1 800 879 8000 Health/Safety: 1 800 879 6000 Jerry Metcalf(x6704) Emergency# (Chem-Trec): 1 800 424 9300(USA,PR,Virgin Islands,Canada); 001 703 527 3887(other countries) The information and recommendations contained herein are based upon data believed to be correct;however, no guarantee or " warranty of any kind expressed or implied is made with respect to the information provided. T. i Hiiti Firestop Saving Lives through innovation HiIt'. Outperform. Outlast. and education Ho,,,inc.(ti S.)1-800-879-8000• www.us.hlItteern•en espanoi 1-800-879-5000•Kit:(Canada)Corp. 1-800-363-4458 Www.Nlti.ca M R Certificate of Corns Bance Certificate Number 20100512-RI3240 Page 1 of 1 Report Reference 2010 May 12 - Issue Date 2010 May 12 Underwriters Laboratories Inc, Issued to: Hilti, Inc. 54 S 122ND East AVe Tulsa, OK 74146 USA This is to certify that Fill, Void or Cavity Materials representative samples of FS-ONE Have been investigated by Underwriters Laboratories Inc.®(UL)or any authorized licensee of UL in accordance with the Standard(s)indicated on this Certificate. Standard(s)for Safety: ANSI/UL 1479,ANSUUL 2079, CAN/ULC-S115-05 Third Edition,revised March 1,2010 Additional Information: FS-ONE Sealant for use in Joint Systems and FS-ONE for use in Through-Penetration Firestop Systems as currently described in the UL Fire Resistance Directory. Only those products bearing the UL Classification Mark should be considered as being covered by UL's Classification and Follow-Up Service. The UL Classification Mark includes:UL in a circle symbol: Q with the word"CLASSIFIED"(as shown); a control number (may be alphanumeric) assigned by UL; a statement to indicate the extent of UL's evaluation of the product; and,the product category name(product identity)as indicated in the appropriate UL Directory. Look for the UL Classification Mark on the product Issueby ,r Reviewed I Mona'Cou Bute 'ht fs son �it3 rwrr#ern.Labpr torr c f' Undwr Laboratarie In . 144 - 14.4 Ani rntati and dainimentatina insotrtng Ut;1"ark ser°ces reproxrci on iwhalf o Inde atonies len UL)or.anv anthnrized licensee ofUUL:, - Certificate of Com ' liance Certificate Number 20060214-RI3240E Report Reference 2006 February 14 Page 1 of 1 Issue Date 2006 February 14 Underwriters YL Laboratories Inc.:: Issued to: Hilti, Inc. 5400 S 122ND East Ave Tulsa, OK 74146 USA This is to certify that Fill, Void or Cavity Materials representative samples of FS-ONE Have been investigated by Underwriters Laboratories Inc. in accordance with the Standard(s) indicated on this Certificate. Standard(s)for Safety: ANSI/UL 1479, ANSI/UL 2079, CAN/ULC-S115-05 Additional Information: FS-ONE Sealant for use in Joint Systems and FS-ONE for use in Through- Penetration Firestop Systems as currently described in the UL Fire Resistance Directory. Only those products bearing the UL Classification Mark should be considered as being covered by UL's Classification and Follow-Up Service. The UL Classification Mark includes: UL in a circle symbol: III with the word "CLASSIFIED" (as shown); a control number (may be alphanumeric) assigned by UL; a statement to indicate the extent of UL's evaluation of the product; and, the product category name(product identity),as indicated in the appropriate UL Directory. Look for the UL Classification Mark on the product Issued by: Reviewed by: mons ouloute Christopher ;; on Underwriters Laboratories Inc. Underwriters 'ratories Inc. 11.111161.11r1111 Hilti North America 5400 South 122nd East Avenue Tulsa,OK 74146 P.O.Box 21148 I Tulsa,OK 74121-1148 T 1-800-879-8000 I F 918-252-6742 www.hilti.com June 27, 2008 To Whom It May Concern: Re: Hilti FS-ONE Intumescent Firestop The Hilti FS-ONE Intumescent Firestop is manufactured in Kaufering, Germany. The FS-ONE pail is made of polyethylene and can be completely recycled. There is no post- consumer or post-industrial content in FS-ONE and it cannot be recycled. The VOC content for FS-ONE is 75 grams/liter. FS-ONE is not regulated as a hazardous waste by the Federal EPA Standards. The regulations for the disposal of non-regulated industrial waste can vary from state to state and even city to city. For this reason, you should consult your local and state regulatory agencies for direction on disposal. Please feel free to contact me at (918) 252-6704 if you have questions. Sincerely, Jerry Metcalf MPH, CHMM Safety/Environmental Manager Hilti Inc (918) 252 6704 jerry.metcalf pnhilti.com II NOTES/DEFINITIONS: 1. Post-Consumer Recycled Content: Portion of material or product derived from discarded consumer waste that has been recovered for use as a raw material[e.g.,plastic bottles, newspaper] 2. Post-Industrial Recycled Content: Portion of material or product derived from recovered industrial and mfg.materials that are diverted from municipal solid waste for use in a different mfg.process,prior to use by a consumer[e.g.,fly-ash in concrete or synthetic gypsum board,both of which are by-products of coal-burning power plants].Spills and scraps from the original manufacturing process that are combined with other constituents after a minimal amount of reprocessing for use in further production of the same product do not qualify. 3. Manufactured: Final assembly of components into building product that is furnished and installed by trades[e.g.,if the hardware comes from Dallas,TX,the lumber from Keene, NH,and the joist is assembled in Kent,WA;then the location of final assembly is Kent,WA]. www.gpsvisualizer.com/calculators can be used to calculate straight-line distance between project site/New York,NY and location of manufacture and raw material source. Note:location noted on material data sheets is often corporate location;need manufacturer to verify actual manufacture location. 4. Raw Materials: Virgin or recovered resources from which the product's components are made[i.e.,before processing or manufacturing]. 5. Rapidly Renewable: Materials and products made from raw materials that are harvested within a 10-year cycle[e.g.,bamboo,cork,linoleum,fast-growing poplar,wheatboard,wool carpet]. 6. FSC Certified: Wood-based products that are certified by the Forest Stewardship Council and carry a Chain-of-Custody certificate number from the vendor or manufacturer. 7. VOC Content: The quantity of volatile organic compounds contained in products such as adhesives,sealants and architectural coatings.VOC content is to be reported in grams/liter or lbs/gallon,less water and any exempt compounds/solvents. CONTRACTOR CERTIFICATION: I, a duly authorized representative of hereby certify that the information contained herein accurately represents the listed"green building"characteristics of the material to be provided by our company as components of the building construction.Furthermore, I understand that any change in such"green building"material characteristics during the purchasing and/or installation period will require prior written approval from the Construction _J Manager and Owner. SIGNATURE OF AUTHORIZED REPRESENTATIVE: DATE: p. of MSDS No.: 259 M,11.II911.1 Revision No.: 010 Revision Date: 08/17/04 ® Page: 1 of 2 MATERIAL SAFETY DATA SHEET Product name: FS-ONE High Performance Intumescent Firestop Sealant Description: One-part acrylic-based sealant Supplier: Hilti, Inc. P.O.Box 21148,Tulsa,OK 74121 Emergency#(Chem-Trec.): 1 800 424 9300(USA, PR,Virgin Islands,Canada);001 703 527 3887(other countries) INGREDIENTS AND EXPOSURE LIMITS �.- xx Aw 1 , n � p9 _. If � :} .., �� L , .M �-.< r��� gyp, _ � s: L� w _ � L: Polyacrylate dispersion Mixture NE NE NE Calcium carbonate 001317-65-3 5 mg/m3(T) 10 mg/m3(T) NE Zinc borate 138265-88-0 NE NE NE Ammonium polyphosphate 068333-79-9 NE NE NE Talc 014807-96-6 20 mppcf 2 mg/m3 NE Expandable graphite 012777-87-6 5 mg/m3(T) 2 mg/m3(T) NE Ethylene glycol 000107-21-1 NE C:100 mg/m3(A) NE Polybutene 009003-29-6 NE NE NE Iron oxide 001309-37-1 10 mg/m3 5 mg/m3 NE Glass filament 065997-17-3 NE 5 mg/m3(T) NE Silicon dioxide 014808-60-7 0.05 mg/m3(T) 0.1 mg/m3(T) NE Water 007732-18-5 NE NE NE Abbreviations: PEL= OSHA Permissible Exposure Limit. TLV=ACGIH Threshold Limit Value. C= Ceiling. STEL=Short Term Exposure Limit. NE=None Established. NA=Not Applicable. (T)indicates"as total dust". (R)indicates"as respirable fraction". (A) indicates"as an aerosol". mppcf=million particles per cubic foot. PHYSICAL DATA Appearance: Red paste. Odor Odorless. Vapor Density: (air=1) Not determined. Vapor Pressure: 23mbar @ 20C/68F Boiling Point: Not applicable. VOC Content 75.0 g/L. Evaporation Rate: Not applicable. Solubility in Water Soluble. Specific Gravity: 1.5 pH: Not determined. FIRE AND EXPLOSION HAZARD DATA Flash Point Non-flammable. Flammable Limits: Not applicable. Extinguishing Media: Not applicable. Use extinguishing media as appropriate for surrounding fire. Special Fire Fighting None known. Use a self-contained breathing apparatus when fighting fires involving chemicals. Procedures: Unusual Fire and Explosion None known. Thermal decomposition products can be formed such as oxides of carbon, sulfur Hazards: and phosphorous. REACTIVITY DATA Stability: Stable. Hazardous Polymerization: Will not occur. Incompatibility: Strong acids,peroxides,and oxidizing agents. Decomposition Products: Thermal decomposition can yield CO and CO2. Conditions to Avoid: None known. HEALTH HAZARD DATA Known Hazards: None known. Signs and Symptoms of Possibly irritating upon contact with the eyes or upon repeated contact with the skin. Exposure: Medical Conditions Eye and skin conditions. Aggravated by Exposure: Routes of Exposure: Dermal. HILT!®is a registered trademark of Hilti Corp. Carcinogenicity: IARC classifies crystalline silica(quartz sand)as Group I based upon evidence among workers in industries where there has been long-term and chronic exposure (via inhalation) to silica dust; e.g. mining, quarry, stone crushing, refractory brick and pottery workers. This product does not pose a dust hazard; therefore, this classification is not relevant. Based upon the nature and intended use of this product, it does not pose an increased cancer risk to workers. EMERGENCY AND FIRST AID PROCEDURES Eyes: Immediately flush with plenty of water. Call a physician if symptoms occur. Skin: Immediately wipe off material and wash with soap and water. Material can adhere to the skin. If • material has adhered to the skin, use an abrasive containing hand cleaner. If material does not come off, buff with a pumice stone. Inhalation: Move victim to fresh air if discomfort develops. Call a physician if symptoms persist. Ingestion: Seek medical attention. Do not induce vomiting unless directed by a physician. If a large quantity was ingested, give 1 to 2 glasses of water to dilute. Never give anything by mouth to an unconscious person. Other: Referral to a physician is recommended if there is any question about the seriousness of the injury/exposure. CONTROL MEASURES AND PERSONAL PROTECTIVE EQUIPMENT Ventilation: General(natural or mechanically induced fresh air movements). Eye Protection: Not required,however,safety glasses should be worn in most industrial settings. Skin Protection: Avoid skin contact.Cloth gloves are suitable for hand protection. Respiratory Protection: None normally required. Where ventilation is inadequate to control vapors, use a NIOSH- approved respirator with organic vapor cartridges. Never enter a confined space without an appropriate air-supplied respirator. PRECAUTIONS FOR SAFE HANDLING AND USE Handling and Storing Store in a cool, dry area preferably between 40°and 77°F. Keep from freezing. Do not store in Precautions direct sunlight. Avoid contact with the eyes or skin. Practice good hygiene; i.e. always wash thoroughly after handling and before eating or smoking. For industrial use only. Keep out of reach of children. Follow label/use instructions. Spill Procedures: Immediately wipe away spilled material before it hardens. Place in a container for proper disposal in accordance with all applicable local,state,or federal requirements. REGULATORY INFORMATION Hazard Communication: This MSDS has been prepared in accordance with the federal OSHA Hazard Communication Standard 29 CFR 1910.1200. HMIS Codes: Health 1, Flammability 0, Reactivity 0, PPE B DOT Shipping Name: Not regulated. IATA✓ICAO Shipping Name: Not regulated. TSCA Inventory Status: Chemical components listed on TSCA inventory. SARA Title III,Section 313: This product contains < 3% ethylene glycol (CAS 107-21-1) and < 15% zinc borate (re: zinc compounds) which are subject to reporting under Section 313 of SARA Title III (40 CFR Part 372). EPA Waste Code(s) Not regulated by EPA as a hazardous waste. Waste Disposal Methods: Consult with regulatory agencies or your corporate personnel for disposal methods that comply with local,state,and federal safety, health and environmental regulations. CONTACTS Customer Service: 1 800 879 8000 Technical Service: 1 800 879 8000 Health/Safety: 1 800 879 6000 Jerry Metcalf (x6704) Emergency#(Chem-Trec): 1 800 424 9300(USA, PR,Virgin Islands, Canada); 001 703 527 3887(other countries) The information and recommendations contained herein are based upon data believed to be correct; however, no guarantee or warranty of any kind expressed or implied is made with respect to the information provided. • MSDS 259, Page 2 of 2 �'0M erten�^Ta,. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION iCAL`�� OFFICE OF THE STATE FIRE MARSHAL FIRE FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM s,r.°E,&g, LISTING SERVICE LISTING No. 4485-1200:108 Page 1 of 1 CATEGORY: Opening Protection (Firestopping) LISTEE: Hilti, Inc., 5400 S. 122nd East Ave, Tulsa, OK 74146 Contact: *Clay Hensley(918)252-6216 Fax(918)254-1679 DESIGN: Model FS-ONE Firestop Sealant. Refer to listee's printed data sheet and UL Fire Resistance Directory for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes&ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, type identification and UL label. APPROVAL: Listed as firestop devices for use in through-penetration firestop system up to 3 hour rating. For indoor use only. Approved under Through-Penetration Fire Stop Systems: CAJ1155, CAJ2091, CAJ2118, CAJ3095, CAJ5044, CAJ8041, F-C-2025,WL1085,WL1056, WL3047,WL5029, WL8004. Refer to UL Fire Resistance Directory for detailed constructions. *Rev.06-20-2006 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results `'ti'�J` and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or I recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation 1 criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 10, 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief ` Fire Engineering Division ir Report of Materials and BUILDINGS Equipment Acceptance Division NYC Department of.Buildings 280 Broadway, New York, NY 10007 Patricia Lancaster, FAIA, Commissioner (212)566-5000,TTY: (212)566-4769 Pursuant to Administrative Code Section 27-131, the following equipment or material has been found acceptable for use subject to the terms and conditions contained herein. MEA 326-96-M Vol. 5 Manufacturer: Hilti, Inc., 5400 S. 122 East Avenue, Tulsa, OK 74146 Trade Name(s): Hilti, Inc. Product: Fill, void or cavity material for fire protection Pertinent Code Section(s): 27-345 Prescribed Test(s): RS 5-19 (ASTM E814), UL 2079 Laboratory: Underwriters Laboratories, Inc. Test Report(s): File R13240, dated July 16, 1993, July 21, 1993, July 13, 1993, July 22, 1993, April 1, 1993, March 25, 1994, March 3 and 6, 1995, September 4, 1996, September 27, 1997; File R13644, dated April 12, 1993 and May 3, 1993; File R12232, dated August 2, 1993; UL-design listings. Description: Fill, void or cavity material for through-penetrations in fire-rated wall and/or floor/ceiling construction. The Hilti FS-ONE Firestop Sealant shall be applied in accordance with Underwriters Laboratories `lnc.`system numbers, listed on following pages, in achieving the required fire-resistance ratings. MEA 326-96-M Vol. 5 Page 1 of 10