Loading...
Report (33) Northwest F' a Suppression, Inc. • FIRE ALARM EQUIPMENT SUBMITTAL FOR Clean Water Services Durham O&M Building Remodel Phase 1B 16060 SW 85th Avenue Tigard, OR 97224 11/21/16 SYSTEM Modification to existing Notifier Addressable Fire Alarm Control System CONTENTS Manufacturers Data Sheets Page 1 of 2 1800 NW 169th Place, Suite C600 • Beaverton, Oregon 97006 • 503-644-7720 • Fax 503-644-8289 www.nwfire.com CCB#088629 Licensed • Bonded • Insured Norwest Fire SuppressionhiC. Fire Alarm Equipment ITEM MODEL DESCRIPTION FSP-851 Addressable Smoke Detector 1 B210LP Low Profile 6" Dia. Detector Base 2 FCPS-24S8 8amp, Sync, Notification Power Supply SR Multi-CD Wall Strobe, Red 3 P2R Multi-CD Wall Horn/Strobe, Red Page 2 of 2 1800 NW 169th Place, Suite C600 • Beaverton, Oregon 97006 • 503-644-7720 • Fax 503-644-8289 www.nwfire.com CCB#088629 Licensed • Bonded • Insured DN-6927:A2 FCPS-24S6(C/E) & FCPS- 24S8(C/E) DNOTIFIER� 6- & 8-Amp 24-Volt by Honeywell Remote Power Su• •lies Power Supplies General The FCPS-24S6E (6-amp) and FCPS-24S8E (8-amp) are remote power supplies with battery charger.The FCPS-24S6/- - 24S8 may be connected to any 12 or 24 volt fire alarm control panel (FACP) or may be used as stand-alone supplies. Pri- mary applications include notification appliance circuit (NAC) expansion (to support ADA requirements and NAC synchroni- zation) or auxiliary power to support 24 volt system accesso- ries.The FCPS-24S6/-24S8 provides regulated and filtered 24 VDC power to four notification appliance circuits configured as either four Class B(Style Y)or Class A(Style Z,with ZNAC-4 option module). Alternately, the four outputs may be config- ured as all non-resettable, all resettable or two non-resettable and two resettable. The FCPS-24S6/-24S8 also contains a battery charger capable of charging up to 18 AH batteries. FCPS-24S6C&FCPS-24S8C are ULC-listed. NOTE: Unless otherwise specified, the terms FCPS-24S6 and FCPS-24S8 used in this document refers to the standard FCPS- 24S6 and FCPS-24S8, FCPS-24S6C and FCPS-24S8C, the FCPS-24S6E and FCPS-24S8E Features • UL-Listed NAC synchronization using System Sensor, • Includes integral battery charger capable of charging up to • Wheelock,or Gentex"Commander2"appliances. 18 AH batteries. Cabinet capable of housing 7.0 AH batter- • Operates as a "sync-follower" or as a "sync-generator" ies. (default). See note on page 2. • Battery charger may be disabled via DIP switch for applica- • Contains two fully-isolated input/control circuits - triggered tions requiring larger batteries. from FACP NAC (NAC expander mode) or jumped perma- • Fixed, clamp-type terminal blocks accommodate up to 12 nently"ON"(stand-alone mode). AWG(3.1 mm2)wire. • Four Class B (Style Y) or four Class A (Style Z, with ZNAC-4 module)NACs. Specifications • 6-amp (FCPS-24S6) or 8-amp (FCPS-24S8) full load out- Primary(AC)Power: put, with 3 amps maximum/circuit, in NAC expander mode (UL 864). • FCPS-24S6C/-24S8C: 120 VAC,60 Hz,3.2A maximum. • 4-amp (FCPS-24S6) or 6-amp (FCPS-24S8) continuous • FCPS-24S6E/-24S8E: 240 VAC,50 Hz, 1.6A maximum. output in stand-alone mode(UL 1481). • Wire Size: minimum#14 AWG(2.0mm2)with 600 V insula- • Compatible with coded inputs;signals passed through. tion. • Optional power-supervision relay(EOLR-1). Control Input Circuit: • In stand-alone mode, output power circuits may be config- • Trigger Input Voltage: 9 to 32 VDC. ured as: resettable, (reset line from FACP required), • Trigger Current: 2.0 mA(16-32 V); Per Input: 1.0 mA(9 non-resettable,or a mix of two and two. -16 V). • Fully regulated and filtered power output-optimal for pow- Trouble Contact Rating: 5 A at 24 VDC. Bring four wire smoke detectors, annunciators, and other Auxiliary Power Output: Specific application power 500 mA system peripherals requiring regulated/filtered power. maximum. • Power-limiting technology meets UL power-limiting require- ments. Output Circuits: • Form-C normally-closed trouble relay. • +24 VDC filtered, regulated. • Fully supervised power supply,battery,and NACs. • 3.0 A maximum for any one circuit. • Selectable earth fault detection. • Total continuous current for all outputs(stand-alone mode): • AC trouble report selectable for immediate 2-hour delay. —FCPS-24S6: 4.0 A maximum. • Works with virtually any UL 864 fire alarm control which uti- —FCPS-24S8: 6.0 A maximum. lizes an industry-standard reverse-polarity notification cir- • Total short-term current for all outputs(NAC expander mode): cuit(including unfiltered and unregulated NAC power). —FCPS-24S6: 6.0 A maximum. • Requires input trigger voltage of 9-32 VDC. —FCPS24S8: 8.0 A maximum. • Self-contained in compact, locking cabinet- 15"H x 14.5"W Secondary Power(Battery)Charging Circuit: x 2.75"D(cm:38.1 H x 36.83W x 6.985D). • Supports lead-acid batteries only. DN-6927:A2•5/17/13—Page 1 of 2 • Float-charge voltage: 27.6 VDC. Standards and Codes • Maximum current charge: 1.5 A. The FCPS-24S6 and FCPS-24S8 comply with the following • Maximum battery capacity: 18 AH. standards: Applications • NFPA 72 National Fire Alarm Code. • UL 864 Standard for Control Units for Fire Alarm Systems Example 1: Expand notification appliance power an additional (NAC expander mode). 6.0 A (FCPS-24S6) or 8.0 A (FCPS-24S8). Use up to four • UL 1481 Power Supplies for Fire Alarm Systems. Class B (Style Y) outputs or four Class A (Style Z) outputs (using ZNAC-4). For example,the FACP notification appliance Agency Listings and Approvals circuits will activate the FCPS when reverse-polarity activation occurs. Trouble conditions on the FCPS are sensed by the These listings and approvals apply to the modules specified in FACP through the notification appliance circuit. this document. In some cases,certain modules or applications Example 2: Use the FCPS to expand auxiliary regulated 24- may not be listed by certain approval agencies, or listing may volt system power up to 4.0 A (FCPS-24S6) or up to 6.0 A be in process.Consult factory for latest listing status. (FCPS-24S8). Both resettable and non-resettable power • UL Listed: S635,S674 options are available. Resettable outputs are created by con- • ULC Listed:S635(FCPS-24S6C&FCPS-24S8C) necting the resettable output from the FACP to one or both of • CSFM Approved: 7315-0028:225 the FCPS inputs. • pp Example 3: Use addressable control modules to activate the MEA: 299-02-E FCPS instead of activating it through the FACP notification • FM Approved appliance circuits.This typically allows for mounting the FCPS at greater distances* away from the FACP while expanding Ordering Information system architecture in various applications. FCPS-24S6: 6.0 A, 120 VAC remote charger power supply. For example, an addressable control module is used to acti- Includes main printed circuit board, transformers, enclosure vate the FCPS,and an addressable monitor module is used to (15"H x 14.5"W x 2.75"D[cm:38.1 H x 36.83W x 6.985D]),and sense FCPS trouble conditions. Local auxiliary power output installation instructions. from the FCPS provides power to the addressable control FCPS-24S6C: Same as above, ULC listed. module. "NOTE:Addressable FACPs are capable of locating control and FCPS-24S6R: Same as FCPS 2456 with red enclosure. monitor modules at distances of up to 12,500 feet(3,810 meters). FCPS-24S6E: 6.0 A, 240 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure Sync Follower/Generator Note (15"H x 14.5"W x 2.75"D[cm:38.1 H x 36.83W x 6.985D]),and installation instructions. In some installations, it is necessary to synchronize the flash power FCPS-24Sf1•' 8.0 A, 120 VAC remote chargersupply. timing of all strobes in the system for ADA compliance. pP y Strobes accomplish this by monitoring very short timing pulses Includes main printed circuit board, transformers, enclosure on the NAC power which are created by the FACP. When (15"H x14.5"W x 2.75"D[cm:38.1 H x 36.83W x 6.985D]),and installed at the end of a NAC wire run,the FCPS-24S6/-2458 installation instructions. can track (i.e. "follow") the strobe synchronization timing FCPS-24S8C Same as above,ULC-listed. pulses on the existing NAC wire run.This maintains the overall FCPS-24S8R: Same as FCPS-24S8 with red enclosure. system flash timing of the additional strobes attaches to the FCPS. FCPS-24S8E: 8.0 A, 240 VAC remote charger power supply. When the FCPS-24S6/-24S8 is configured(via DIP switch set- Includes main printed circuit board, transformers, enclosure tings) as a"sync follower,"the FCPS's NAC outputs track the (15"H x 14.5"W x 2.75"D[cm:38.1 H x 36.83W x 6.985D]),and strobe synchronization pulses present at the FCPS's sync installation instructions. input terminal.The pulses originate from an upstream FACP or ZNAC-4: Class A(Style Y)NAC option module. other power supply. EOLR-1: 12/24 VDC end-of-line relay for monitoring four-wire When the FCPS-24S6/-24S8 are configured (via DIP switch smoke detector power. settings) as a "sync generator," the FCPS's sync input termi- BAT-1270: Battery, 12-volt, 7.0 AH (two required, see BAT nals are not used. Rather, the FCPS is the originator of the Series data sheet DN-6933). strobe synchronization pulses on the FCPS's NAC outputs. In "sync generator"mode,the sync type(System Sensor,Whee- lock,or Gentex)is selectable via DIP switch settings. System Sensor®and NOTIFIER®are registered trademarks of Honeywell International Inc. ©2013 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. • C E R T F t E We cannot cover all specific applications or anticipate all requirements. ENCINEMN6 8 MANRFACTURIN6 All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—DN-6927:A2•5/17/13 DN-6935:E•H-202 FSP-851'(A) Series NOTI FI E R® Intelligent Plug-In Photoelectric Smoke Detectors with FlashScan® by Honeywell intelligent/Addressable Devices General Notifier FSP-851(A) Series intelligent plug-in smoke detec- 1, tors with integral communication provide features that sur- pass conventional detectors. Detector sensitivity can be /1 programmed in the control panel software. Sensitivity is con tinuously monitored and reported to the panel. Point ID capa- bility allows each detector's address to be set with rotary, decimal address switches, providing exact detector location for selective maintenance when chamber contamination reaches an unacceptable level. The FSP-851(A) photoelec- ' tric detector's unique optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources. Dual electronic thermistors add 135°F(57°C)fixed- temperature thermal sensing on the FSP-851T(A).The FSP- 851R(A) is a remote test capable detector for use with FSP-851(A) in B210LP(A) Base DNR(A)/DNRW duct detector housings. FSP-851(A) series detectors are compatible with Notifier Onyx and CLIP series Fire Alarm Control Panels(FACPs). FlashScan® (U.S. Patent 5,539,389) is a communication Specifications protocol developed by Notifier that greatly increases the Sensitivity: 0.5%to 2.35%per foot obscuration speed of communication between analog intelligent devices. Size:2.1"(5.3 cm)high; base determines diameter. Intelligent devices communicate in a grouped fashion. If one of the devices in the group has new information, the panel's —B210LP(A): 6.1"(15.5 cm)diameter. CPU stops the group poll and concentrates on single points. —B501(A):4.1" (10.4 cm)diameter. The net effect is response speed greater than five times that _g200S(A):6.875" (17.46 cm)diameter. of earlier designs. —B200SR(A):6.875" (17.46 cm)diameter. Features -B224RB(A):6.2"(15.748 cm)diameter. • Sleek, low-profile design. —B224BI(A): 6.2"(15.748 cm)diameter. • Addressable-analog communication. Shipping Weight:5.2oz. (147g). • Stable communication technique with noise immunity. Operating Temperature range: FSP-851(A), 0°C to 49°C • Low standby current. (32°F to 120°F). FSP-851T(A), 0°C to 38°C (32°F to 100°F). Low temperature signal for FSP-851T(A) at 45°F +/- 10°F • Two-wire SLC connection. (7.22°C +/- 5.54°C). FSP-851 R(A) installed in a DNR(A)/ • Compatible with FlashScan®and CLIP protocol systems. DNRW,-20°C to 70°C(-4°F to 158°F). • Rotary,decimal addressing(1-99 on CLIP systems, 1-159 UL/ULC Listed Velocity Range: 0-4000 ft/min. (1219.2 m/ on FlashScan systems). min.),suitable for installation in ducts. • Optional remote,single-gang LED accessory. Relative Humidity: 10%-93%noncondensing. • Dual LED design provides 360°viewing angle. Thermal Ratings: Fixed-temperature setpoint 135°F(57°C). • Visible bi-color LEDs blink green every time the detector is addressed, and illuminate steady red on alarm (FlashS- DETECTOR SPACING AND APPLICATIONS can systems only). Notifier recommends spacing detectors in compliance with • Remote test feature from the panel. NFPA 72. In low airflow applications with smooth ceiling, • Walk test with address display (an address on 121 will space detectors 30 feet (9.144m) for ceiling heights 10 feet blink the detector LED: 12-[pause]-1(FlashScan systems (3.148m) and higher. For specific information regarding only). detector spacing,placement,and special applications refer to Built-in functional test switch activated by external magnet. NFPA 72. System Smoke Detector Application Guide, docu- • ment A05-1003, is available at systemsensor.com • Built-in tamper-resistant feature. • Sealed against back pressure. ELECTRICAL SPECIFICATIONS • Constructed of off-white fire-resistant plastic, designed to Voltage Range: 15-32 volts DC peak. commercial standards, and offers an attractive appear- Standby Current (max. avg.): 300pA @ 24VDC (one com- ance. munication every five seconds with LED enabled). • 94-5V plastic flammability rating. LED Current(max.):6.5mA @ 24 VDC("ON"). • SEMS screws for wiring of the separate base. • Optional relay, isolator,and sounder bases. DN-6935:E•2/11/2015—Page 1 of 2 Installation B210LPBP: Bulk pack of B210LP; package contains 10. FSP-851(A)plug-in detectors use a separate base to simplify B501(A):Standard European flangeless mounting base. installation, service, and maintenance. A special tool allows B501 BP: Bulk pack of B501; package contains 10. maintenance personnel to plug in and remove detectors with- out using a ladder. B200S(A): Intelligent, programmable sounder base capable Mount base(all base types)on an electrical backbox which is of producing sound output in high or low volume with ANSITemporal 3, at least 1.5" (3.81 cm) deep. For a chart of compatible junc- and custom tone. ANSI Temporal 4, continuous tone, marching tone, tion boxes,see DN-60054. B200SR(A): Intelligent sounder base capable of producing NOTE: 1) Because of inherent supervision provided by the SLC sound output with ANSI Temporal 3 or continuous tone. loop, end-of-line resistors are not required. Wiring `T-taps" or Replaces 8501 BH series bases in retrofit applications. branches are permitted for Style 4 (Class `B') wiring. 2) When using relay or sounder bases, consult the ISO-X(A) installation B224RB(A): Plug-in System Sensor relay base. Screw ter- sheet 156-1380 for device limitations between isolator modules minals:up to 14 AWG(2.0 mm2). Relay type:Form-C. Rating: and isolator bases. 2.0 A @ 30 VDC resistive;0.3 A @ 110 VDC inductive; 1.0 A @ 30 VDC inductive. Agency Listings and Approvals B224BI(A): Plug-in System Sensor isolator detector base. These listings and approvals apply to the modules specified Maximum 25 devices between isolator bases. in this document. In some cases,certain modules or applica- tions may not be listed by certain approval agencies,or listing ACCESSORIES may be in process. Consult factory for latest listing status. F110: Retrofit flange to convert B210LP(A) to match the • UL Listed: S1115. B710LP(A) profile, or to convert older high-profile bases to ULC Listed: S1115 (FSP-851A, FSP-851RA, FSP- low-profile. • 851TA). F110BP: Bulk pack of F110;package contains 15. • MEA Listed:225-02-E. F210: Replacement flange for B210LP(A)base. • FM Approved. RA100Z(A): Remote LED annunciator. 3—32 VDC. Mounts • CSFM:7272-0028:0206. to a U.S. single-gang electrical box. For use with B501(A) • Maryland State Fire Marshal: Permit#2122. and B210LP(A)bases only. • BSMI: CI313066760036. SMB600:Surface mounting kit • CCCF: Certif.#2004081801000017(FSP-851T) M02-04-00:Test magnet. Certif.#2004081801000016(FSP-851). M02-09-00:Test magnet with telescoping handle. • U.S. Coast Guard: 161.002/42/1 (NFS-640); 161.002/50/ 0(NFS2-640/NFS-320/NFS-320C,excluding B210LP(A)). XR2B: Detector removal tool. Allows installation and/or • Lloyd's Register: 11/600013 (NFS2-640/NFS-320/NFS- removal of detector heads from bases in high ceiling applica- 320C, excluding B210LP(A)). tions. XP-4: Extension pole for XR2B.Comes in three 5-foot(1.524 Product Line Information m)sections. NOTE:"A"suffix indicates ULC Listed model. T55-127-010: Detector removal tool without pole. FSP-851: Low-profile intelligent photoelectric sensor. Must BCK-200B: Black detector covers for use with FSP-851(A) be mounted to one of the bases listed below. only; box of 10. FSP-851A:Same as FSP-851 but with ULC listing. WCK-200B: White detector covers for use with FSP-851(A) FSP-851T: Same as FSP-851 but includes a built-in 135°F only;box of 10. (57°C)fixed-temperature thermal device. FSP-851TA:Same as FSP-851T but with ULC listing. FSP-851 R: Low-profile intelligent photoelectric sensor, remote test capable. For use with DNRA/DNRW. FSP-851 RA: Same as FSP-851 R but with ULC listing. For use with DNRA. INTELLIGENT BASES NOTE:"A"suffix indicates ULC Listed model. NOTIFIER®is a registered trademark of Honeywell International Inc. NOTE:For details on intelligent bases,see DN-60054. 02015 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. B210LP(A): Standard U.S. flanged low-profile mounting base. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. • E RT F E O We cannot cover all specific applications or anticipate all requirements. MCMINN6 8 MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—DN-6935:E•2/11/2015 DN-7087:01 SpectrAlert® Advance ® Selectable Output N 0►T 1 F 1 E R Notification Appliances by Honeywell Audio/Visual Devices General System Sensor® SpectrAlert® Advance selectable-output ��' horns,strobes and horn/strobes are rich with features guaran- 4 •�i teed to cut installation times and maximize profits.The Spec- fes trAlert Advance series of notification appliances is designed to € ' simplify your installations, with features such as: plug-in designs,instant feedback messages to ensure correct Indoor Ceiling Outdoor Ceiling tion of individual devices,and eleven field-selectable candela Horn/Strobe Strobe settings for wall and ceiling strobes and horn/strobes. . More specifically, when installing Advance products, first attach a universal mounting plate to a four-inch square,four- � 41 inch octagon, or double-gang junction box. The two-wire a 4 mounting plate attaches to a single-gang junction box. e ° I ',-- Then, connect the notification appliance circuit w€ring to the SEMS terminals on the mounting plate. indoor Wall Indoor Ceiling Finally,attach the horn,strobe,or horn/strobe to the mounting Horn/Strobe Strobe plate by inserting the product's tabs in the mounting plate's rAre. grooves.The device will rotate into position, locking the prod- t uct's pins into the mounting plate's terminals.The device will � temporarily hold in place with a catch until it is secured with a captured mounting screw. 1 SpectrAlert Advance products allow you to choose: • 12 or 24 volts. Indoor Wall Outdoor Wall • 15, 15/75,30,75,95, 110, 115,135,150, 177,or 185 can- Horn Strobe dela by way of a rear-mounted slide switch and front view- • Outdoor products rated from-40°F and 151°F(-40°C and Ing window. 66°C). • Horn tones and volume by way of a rotary switch. • Outdoor products rainproof per UL50 (NEMA 3R) and • The SpectrAlert Advance series includes outdoor notifica- tion appliances. Outdoor strobes and horn/strobes (two- • Minimal intrusion into the backbox. wire and four-wire)are available for wall or ceiling. Outdoor • Horn rated at 88+dbA at 16 volts. horns are available for wall only.All System Sensor outdoor • Rotary switch for tone selection. products are rated between-40°F and 151°F(-40°C and Three horn volume settings. 66°C)in wet or dry applications. • Models available: • Electrically compatible with existing SpectrAlert products: • Indoor wall-mount: horn, strobe,2-wire horn/strobe,4-wire Engtering Specifications horn/strobe. • Indoor ceiling-mount: strobe, 2-wire horn/strobe, 4-wire SpectrAiert Advance horns, strobes, and horn/strobes shall horn/strobe. mount to a standard 4.0"x`4.0"x 1.5°(10.16 x 10.16 x 3.81 Outdoor wail mount: horn, strobe, 2-wire horn/strobe, 4 cm)backbox,4.0"(10.16 cm)octagonal backbox,or a double- • wire horn/strobe. gang backbox.Two-wire products shall also mount to a single gang 2,0"x 4.0"x1.875"(5.08 x 10.16 x 4.763 cm)backbox.A • Outdoor ceiling-mount: strobe, 2-wire horn/strobe, 4-wire universal mounting plate shall be used for mounting ceiling horn/strobe, and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, Spec- Features trAlert Advance products, when used with the Sync•CircuitTM Plug-in design. Module accessory,shall be powered from a non-coded not!- , cation appliance circuit output and shall operate on a nominal • Same mounting plate for wall-and ceiling-mount units. 12 or 24 volts. When used with the Sync•Circuit Module, 12- • Shorting spring on mounting plate for continuity check volt rated notification appliance circuit outputs shall operate before installation. between 9 and 17.5 volts; 24-volt rated notification appliance • Captive mounting screw. circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32°F and • Tamper-resistance capability. 120°F(0°C and 49°C)from a regulated DC,or full-wave-recti- • Field-selectable candela settings on wall and ceiling units: fled, unfiltered power supply. Strobes and horn/strobes shall 15,15/75,30,75,95,110,115, 135,150,177, 185. have field-selectable candela settings including 15, 15/75,30, • Automatic selection of 12 or 24 volt operation at 15 and 15/ 75,95, 110, 115, 135, 150, 177, 185. 75 candela. • Outdoor wall and ceiling products. DN-7087:01•11/9/11-Page 1 of 4 STROBE Operating Specifications The strobe shall be a System Sensor SpectrAlert Advance • Standard operating temperature: 32°F to 120°F (0°C to Model listed to UL 1971 and shall be approved for fire 49°C) protective service.The strobe shall be wired as a primary-sig- • K Series operating temperature:-40°F to 151°F(-40°C naling notification appliance and comply with the Americans to 66°C). with Disabilities Act requirements for visible signaling appli- ances,flashing at 1 Hz over the strobe's entire operating volt • Humidity range 10% to 93% non-condensing (indoor age range:The strobe light shall consist of a xenon flash tube products). and associated lens/reflector system. • Strobe flash rate•1 flash per second. HORN/STROBE COMBINATION • Nominal voltage: regulated 12 VDC/FWR or regulated 24 VDC/FWR. NOTE Full Wave Rectified(FWR)voltage is a The horn/strobe shall be a System Sensor SpectrAlert non-regulated, time-varying power source that Is used on Advance Model listed to UL 1971 and UL 464 and some power supply and panel outputs. shall be approved for fire protective service. The horn/strobe • Operating voltage range:8 V to 17.5 V(12 V nominal);or shall be wired as a primary-signaling notification appliance 16 V to 33 V(24 V nominal).NOTE P,S,PC,and SC prod and comply with the Americans with Disabilities Act require- acts will operate at 12 V nominal only for 15 cd and 15/75 ments for visible signaling appliances,flashing at 1 Hz over the cd strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector sys- • Input terminal wire gauge: 12 to 18 AWG(3.31 to 0:821 tem.The horn shall have three audibility options and an option mm2). to switch between a Temporal 3 pattern and a Non-Temporal • Ceiling-mount dimensions(including lens): 6,8"dame- (continuous)pattern.These options are set by a multiple posi- ter x2.5°'deep(17.3 crn diameter x 6.4 cm deep). tion switch.On four-wire products,the strobe shall be powered • Wall-mount dimensions(including lens):5.6 H x 4.7"W Independently of the sounder.The horn on horn/strobe models x-2.5"D(14.2 cm H x 11.9 cm W x 6.4 cm D). shall operate on a coded or non-coded power supply. • Horn dimensions: 5.6"H x 4,7"W x 1,3"D(14.2 cm H x OUTDOOR PRODUCTS 11.9 cm W x 3.3 cm D). SpectrAlert Advance outdoor horns,strobes and horn/strobes shall be listed for outdoor use by UL and shall operate Agency Listings and Approvals between -40°F and 151°F (-40°C and 66°C). The products The listings and approvals below apply to SpectrAlert Advance shall be listed for use with a System Sensor outdoor/weather- Selectable Output Notification Devices.In some cases,certain proof backbox with half-inch and three-fourths-inch conduit modules may not be listed by certain approval agencies, or entries, listing may be in process. Consult factory for latest listing sta- ... SYNCHRONIZATION MODULE tus. The module shall be a System Sensor Sync•Circuit MDL3R or • UL Listed: 54011 (HR_, HW_, P2_, P4_, PC2_, MDL3W listed to UL 464 and shall be approved for fire protec- PC4models); 55512 (models SCR, SCRH, SCAN, live service.The module shall synchronize SpectrAlert strobes SCWH, SR, SRH, SW, SWH), S3593 (SCRHK, SCRK, at 1 Hz and horns at Temporal 3. Also, while operating the SRHK,SRK). strobes, the module shall silence the horns on horn/strobe • ULC Listed: 54011 (HRA, HRKA); S5512 (typically "A° models over a single pair of wires.The module shall mount to models, with exception of outdoor strobes). See Canadian a 4.688"x 4.688"x 2.125"(11.906 x 11.906 x 5;398 cm)back- data sheet for listings and specifications. box.The module shall also control two Style Y (class B) dr- FM approved cults or one Style Z (Class A) circuit. The module shall a MEA:452-05-E synchronize multiple zones, Daisy-chaining two or more syn- chronization modules together will synchronize all the zones * CSFM: 7125-1653:0186 (SCR, SCRH; SOW, SCWH, SR, they control.The module shall not operate on a coded power SRH,SW,SWH);7300-1653:0188(P2_, P4T, PC2_, PC4_ supply. modules);; 7135-1653:0189 (HR, HRK, HW); 7300- 1653:0187(SCRHK,SOAK,SRHK,SRK). Strobe Current Draw, Horn Current Draw, UL Maximum (mA RMS) UL Maximum (mA RMS) 8-17.5V 16-33V Sound 8-17.5V 16-33V Candela Pattern dB DC FWR DC FWR DC FWR DC FWR 15 123 128 66 71 Temporal High 57 55 69 75 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Standard 30 NA N/A 94 96 Temporal Low 38 44 44 48 Candela 75 NA NA 158 153 Non-temporal High 57 56 69 75 Range 96 NA NA 181 176 Non-temporal Medium 42 50 60 69 110 NA NA 202 195 Non-temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 135 NA NA 228 207 Coded Medium 44 51 56 69 High 150 NA NA 246 220 Coded Low 40 46 52 50 Candela 177 NA NA 281 251 Range 185 NA NA 286 258 Page 2 of 4—DN-7087:01.11/9/11 Horn and Horn/Strobe Horn and Horn/Strobe Output (dBA) Rotary Switch Setting 8—17.5 V 16—33 V Setting Repetition Rate dB Level Switch Sound dB Position Pattern DC FW DC FW 1 Temporal horn High R R 2 Temporal horn Medium 1 Temporal High ' 78 78 84 84 3 Temporal horn Low 2 Temporal Medium 74 74 80 80 4 Normal horn High 3 Temporal Low 71 73 76 76 5 Normal horn ,Medium 4 Non-temporal High '82 82 88 88 6 Normal horn Low 5 Non-temporal Medium 78 78 85 85 7* Externally coded High 6 Non temporal Low 75 75 81 81 8* Externally coded Medium 7* Coded High 82 82 88 88 9* Externally coded Low 8* Coded Medium 78 78 85 85 *NOTE:Settings 7,8,and 9 are not available 9* Coded Low 75 75 81 81 on 2-wire horn/strobe. *NOTE:Settings 7,8,and 9 are not available on 2-wire ham/strobe. Two-Wire Horn/Strobe, STANDARD Candela Range (15 - 115 cd), UL Maximum Current Draw(mA RMS) Input,Sound Pattern,dB 8-17.5 V 16—33 V Level 15 15/75 15 15175 30 75 95 110 115 DC input,Temporal,High 137 147 79 90 107 176 194 212 218 DC Input,Temporal,Medium 132 144 69 '80 97 157 182 201 210 DC Input,Temporal,Low 132 143 66 77 93 154' 179 198 207 " DC Input,Non-temporal,High 141 152 91 100 116 176 ,201 221 '229 DC Input,Non-temporal,Medium 133 145 75 85 102 163 187 207 216 DC Input,Non-temporal,Low 131 144 68 79 96 156 182 201 210 FWR Input,Temporal,High 136 155 88 97 112 168 190 210 218 FWR Input,Temporal,Medium 129 152 78 88 103 160 184 202 206 FWR Input,Temporal,Low 129 151 76 86 101 160 184 194 201 FVVR Input,Non-temporal,High 142 161 103 112 126 181 203 221 229 FWR Input,Non-temporal,Medium 134 155 85 95 110 166 189 208 216 FWR Input,Non-temporal,Low 132 154 80 90 105 161 184 202 211 Two-Wire Horn/Strobe, HIGH Candela Range(135 - 185 cd), UL Maximum Current Draw (mA RMS) 16-33V 16 33V DC Input FWR Input 135 150 177 185 135 150 177 185 DC,Temporal,High 245 '259 290 297 FWR,Temporal,High 215 231 258 265 DC,Temporal,Medium 235 253 288 297 FWR,Temporal,Medium 209 224 250 258 DC,Temporal,Low 232 251 282 292 FWR,Temporal,Low 207 221 248 256 DC,Non-temporal,High 255 270 303 309 FWR,Non-temporal,High 233 248 275 281 DC,Non-temporal,Medium 242 259 293 299 FWR,Non-temporal,Medium 219 232 262 267 DC,Non-temporal,Low 238 254 291 295 FWR,Non-temporal,Low 214 229 256 262 7097dmm12009.e 1 4.7" �.-_ 6.8" 1111 7 71--L---1119"1111 I� P 1, 25„kilo.. __., i 1t1560 ! DN-7087.C1•1119/11—Page 3 of 4 Ordering Information Model Description Model Description WALL HORN/STROBES CEILING HORN/STROBES P2R 2-wire hom/strobe,standard cd,red. PC2R 2-wire hom/strobe,standard cd,red. P2RH 2-wire hom/strobe,high cd,red. PC2RH 2-wire horn/strobe,high cd,red. P2RK 2-wire horn/strobe,standard cd,red,outdoor. PC2RK 2-wire horn/strobe,standard cd,red,outdoor. P2RHK 2-wire horn/strobe,high cd,red,outdoor. PC2RHK 2-wire homistrobe,high cd,red,outdoor, P2W 2-wire hom/strobe,standard cd,white. PC2W 2-wire horn/strobe,standard cd,white. P2WH 2-wire horn/strobe,high cd,white. PC2WH 2-wire horn/strobe,high ed,white. P4R 4-wire hom/strobe,standard cd,red. PC4R 4-wire horn/strobe,standard cd,red. P4RH 4-wire horn/strobe,high cd,red. PC4RH 4-wire horn/strobe,high cd,red. P4RK 4-wire horn/strobe,standard cd,red,outdoor. PC4RK 4-wire horn/strobe,standard cd,red,outdoor. P4RHK 4-wire horn/strobe,high cd,red,outdoor. PC4RHK 4-wire hom/strobe,high cd,red,outdoor. P4W 4-wire hom/strobe,standard cd,white. PC4W 4-wire horn/strobe,standard cd,white. P4WH 4-wire hom/strobe,high cd,white. PC4WH 4-wire hom/strobe,high cd,white. WALL STROBES CEILING STROBES SR Strobe,standard cd;red. SCR Strobe,standard cd,red. SRH Strobe;high cd,red. SCRH Strobe,high cd,red. SRK Strobe,standard cd,red,outdoor. SCRK Strobe,standard Cd,red,outdoor. SRHK Strobe,high cd,red,outdoor. SCRHK Strobe,high cd,red,outdoor. SW Strobe,standard cd,white. SCW Strobe,standard cd,white. SWH Strobe,high cd,white. SCWH Strobe,high cd,white. ACCESSORIES HORNS BBS-2A Backbox skirt,wall,red. HR Horn,red. BBSW-2A Backbox skirt,wall,white. HRK Horn,red,outdoor. BBSC-2A Backbox skirt,ceiling,red. 11W Horn,white. BBSCW-2A Backbox skirt,ceiling,white. ACCESSORIES,continued SA-WBB Weatherproof backbox,wall. TR-HS Trim Ring,wall,red,package of 5 SA-WBBC Weatherproof backbox,ceiling. TRW-HS Trim Ring,wall,white,package of 5 WTP Weatherproof,flush mount plate,red TRC-HS Trim Ring,ceiling,red,package of 5 WTPW Weatherproof,flush mount plate,white TRCW-HS Trim Ring,ceiling,white,package of 5 NOTE: "High cd"refers to strobes that include 135, 150, 177, and 185 candela settings. 'Standard cd"refers to strobes that include 15, 15/75,30, 75,95, 110,and 115 candela settings. NOTE: For strobes and horn/strobes,add suffix'F"far French or B"for Bilingual. NOTE: All outdoor models('K(A)"suffix)include a plastic weatherproof backbox. NOTE: Add`-R"to models for weatherproof replacement device (no back box included). Only for use with weatherproof outdoor flush mounting plate, WTP and WTPW. NOTE: Add"P"to model for plain housing. (No"FIRE"marking on cover.) Sync•CircuitT'" is a trademark and NOTIFIER® and SpeetrAlert® are registered trademarks of Honeywell International Inc. ©2011 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. G E R T F E d We cannot cover all specific applications or anticipate all requirements. • ENOINEEAIN68MANUFAC1UAU96 All specifications are subject to change without notice. QUALITY SYSTEMS For more information,contact Nattier.Phone:(203)484-7161,FAX (203)484-7118.. www.notifier.com Page 4 of 4—DN-7087:C1•11/9/11