Loading...
Permit (2) '1 CITY OF TIGARD MASTER PERMIT :' COMMUNITY DEVELOPMENT Permit#: MST2017-00006 T R in 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 02/14/2017 Parcel: 2S106DB12300 Jurisdiction: Tigard Site address: 17483 SW SHADOW TRAIL ST Subdivision: RIVER TERRACE NORTHWEST Lot: 123 Project: River Terrace Northwest, Lot 123 Project Description: New SF. 4/13/17: REPRINT to add patio cover. BUILDING Floor Areas Required Setbacks Required Stories: 2 Bedrooms: 4 First: 978 sf Basement: 0 sf Left 3 Parking Spaces: 0 Height: 28 Bathrooms: 3 Second: 1251 sf Garage: 380 sf Front: 8 Smoke Dwelling Units: 1 Third: 0 sf Right: 3 Detectors: Yes Total: 2229 sf Value: $273,680.89 Rear: 10 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 5 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Storm Sewer: 100 Drains: 0 Tubs/Showers: 3 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 4 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 4 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'I 500 sf: 3 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: N Other Description: Ecompasing: Y BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SF VB R-3 2229 Owner: Contractor: ADLV LAND HOLDINGS LLC WILLIAM LYON HOMES INC Required Items and Reports(Conditions) BY FORSUM,MICHAEL 109 E 13TH STREET 1 Ersn Cntrl 503-639-4175 7600 E DOUBLETREE RANCH RD VANCOUVER,WA 98660 2 Fire Rated Eaves-Both STE 1 Sides SCOTTSDALE,AZ 85258 PHONE: PHONE: 360-695-7700 FAX: Total Fees: $32,284.18 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You m obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: /P14• Permittee Signature: cG7i Cr/it C/40- 47 Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. FOR OFFICE USE ONLY—SITE ADDRESS: This form is recognized by most building departments in the Tri-County area for transmitting information. Please complete this form when submitting information for plan review responses and revisions. This form and the information it provides helps the review process and response to your project. City of Tigard • COMMUNITY DEVELOPMENT DEPARTMENT III n Transmittal Letter GA is t 13125 SW Hall Blvd. • Tigard, Oregon 97223 • 503.718.2439 • www.tigard-or.gov TO: Tom H. DATE RErCEcWED: DEPT: BUILDING DIVISION RECEIVED APR 3 2017 FROM: Angela Grajewski CITY OF TIGARD COMPANY: Polygon Northwest BUILDING DIVISION PHONE: 971-212-2144 ny://(' RE: 17483 SW Shadow Trails ST MST2017-00006 (Site Address) (Permit Number) River Terrace Northwest Lot 123 (Project name or subdivision name and lot number) ATTACHED ARE THE FOLLOWING ITEMS: ':,-Catitii-Y,11- 7,P"n"Ldir'' lfin.',07Atiiiir*IF-Del :***.iii:0 :--iinrgqir: -.;::; ;•:- 0 Additional set(s) of plans. 3 Revisions: Beek / ( y 0 0 Cross section(s) and details. 0 Wall bracing and/or lateral analysis. 0 Floor/roof framing. 0 Basement and retaining walls. 0 Beam calculations. 0 Engineer's calculations. 0 Other(explain): REMARKS: Please pay fees owed with Trust Account. add 4edrdue to terrain Gekrr ✓ O F , .�. �; ..a4 .K� ".`. .>1' �._. - tInitials: �� .,a. Routed to Pe Technician: Date: Li 5 1') Fees Due: [Yes ❑No F e escriijr_']tion:/ Amo',p7'' t Dusit / s - Special Instructions: Reprint Permit(per PE): `tij Yes ❑No A Done Applicant Notified: Date: 11`0 �(7 Initials:i , I:1Building\Forms\TransmittalLetter-Revisions.doc 05/25/2012 a City of Tigard ■ 111111 COMMUNITY DEVELOPMENT DEPARTMENT T A R o Building Permit Review — Residential Building Permit #: /`'S7 7 ' 7— 00 0 O 6, Site Address: nz1433 &W siretdow T i 1 I sifeet' Project Name: 2\Jier 'Terrace Noe►wic1- Lot #: 123 (New dwelling=subdivision name;Addition or Alteration=last name of owner) Planning Review QI Proposal: 1ktAi, /11k) P-Pad ' -T p la-Verify site address/suite#exists and active in permit system. 'River Terrace Neighborhood: 0 No W,Yes,See River Terrace Review Addendum Attached Site Plan Elements: Gree(3)copies of site plan '/A = 'sting structures on site 152etite plan must on 8-1/2"x 11"or 11 x 17"paper :1 ootprint of new structure(including decks)with finished Drawn to scale(standard architect or engineer scale) floor elevations Orth arrow 'UUtt3ity locations(required for new,may apply for additions) �►_-ite address,project or subdivision name and lot number /�A •cation of wells/septic systems ' pplicant information(name and phone number) 7►?1' :sting trees to be retained with drip line,and tree •t dimensions and building setback dimensions •rotection measures =' •t area,building coverage area,percentage of coverage andStreet tree size,type and location ,$ impervious area(applicable if R-7,R-12,R-25&R-40) Street names rg'roperty corner elevations(2 foot contour lines if more than 4 foot differential) Clean Water Services—Service Provider Letter(lot platted prior to 9/10/1995): Required: 0 Yes,applicant was notified No Received: ❑ Yes El No Or Public Facilities Improvement(PR)Permit: Required: 0 Yes,applicant was notified No Applied For: 0 Yes 0 No,stop intake l Land Use Case#: PD'R2C - ccoos Zoning: W-1 C P D Required l uired Setbacks: Front s Rear tel Side '3 Street Side / Garage Landscape Requirement: % ALot Coverage Maximum: 6D % 2rBuilding Height Maximum Height iJ I N Actual Height t2 Visual Clearance Easements ..k Sensitive Lands: 0 Yes .Br No Type XrUrban Forestry Plan ,Conditigns"Met"prior to issuance of building permit Notes: L. C i! . me pdoc ‘44si&4 .V1 CP , S' . d"-eeI/►tLS L� €e "f r Approved By Planning: iv/I L` 1'/ 1. Date: 12 22_ 1143 Revisions(after ing Submittal o i B ) Revi . ate Revision 1: LE Approved ❑ Not Approved 1� ' (___, ' I/ 40'9 Revision 2: 0 Approved 0 Not Approved Revision 3: 0 Approved 0 Not Approved , I:1Building\Forms\BldgPennitRvw_RES_091216.docx • r• Building Permit Submittal Original Submittal Date: /02/P-cyi Site Plans: # ''3 Building Plans: # -17 - Building Permit#: E Enter building permit#above. Workflow Routing. a-Planning P'Engineering a--Permit Coordinator ©--Building Workflow Sign-off: iE'Sign-off for Planning(include notes from planning review) Route Application Documents: Engineering: (1) copy of permit application,(1) site plan,(1)building plan and original plan review routing form. Building: original permit application,site plans,building plans,engineer and beam calculations and trust details,if applicable,etc. Notes: By Permit Technician: `r _. Date: //y/7 Engineering Review Slope at building pad: joie: 410 Conditions"Met"prior to issuance of building permit O Easements(encroachments)per engineering conditions of approval and plat 0 Water Quality/Quantity Facility. Assess Water Quality Fee in-lieu: 0 Yes 0 No Assess Water Quantity Fee in-lieu: 0 Yes 0 No LIDA Facility on lot: 0 Yes 0 No O NOT Approved by Engineering: Date: Notes: Approved by Engineering: Date: 1:-/-77 Revisions(after Building Submittal only) Reviewer Dam Revision 1: ,Approved 0 Not Approved itlatC/7 Revision 2: 0 Approved 0 Not Approved Revision 3: 0 Approved 0 Not Approved Permit Coordinator Review ❑ Conditions"Met"prior to issuance of building permit pproved,NOT Released: /y� %O ate: Notes: Revisions(after Building Submittal only) Revision Notice 1: Date Sent to Applicant: Revision Notice 2: Date Sent to Applicant: Revision Notice 3: Date Sent to Applicant: DC Fees Entered: Wash Co Trans Dev Tax: es , 0 N/A;` Tigard Trans SDC: Yes 0 N/A Parks SDC: L Yes 0 N/A OK to Issue Permit , // 4/er Approved by Permit Coordinator: Jmate: 0.5 /9— /1y/d - r 1 I:1Building\Forms\BldgPermitRvw_RES 091216.docx 4 J/