Loading...
Permit (24) CITY OF TIGARDMASTER PERMIT .--- .. PIN 2. COMMUNITY DEVELOPMENT Permit#: MST2017-00008 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 02/14/2017 T G �11.L 9 Parcel: 2S106DB12700 Jurisdiction: Tigard Site address: 17407 SW SHADOW TRAIL ST Subdivision: RIVER TERRACE NORTHWEST Lot: 127 Project: River Terrace Northwest, Lot 127 Project Description: New SF.4/12/17: REPRINT to add patio cover. BUILDING Floor Areas Required Setbacks Required Stories: 2 Bedrooms: 4 First: 978 sf Basement: 0 sf Left: 3 Parking Spaces: 0 Height: 24 Bathrooms: 3 Second: 1251 sf Garage: 380 sf Front: 8 Smoke Dwelling Units: 1 Third: 0 sf Right: 3 Detectors: Yes Total: 2229 sf Value: $274,261.21 Rear: 10 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 5 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Storm Sewer: 100 Tubs/Showers: 3 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Drains: 0 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 4 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 4 Fu rn>=100 K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add',500 sf: 4 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: N Other Description: Ecompasing: Y BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SF VB R-3 2229 Owner: Contractor: ADLV LAND HOLDINGS LLC WILLIAM LYON HOMES INC Required Items and Reports(Conditions) BY FORSUM,MICHAEL 109 E 13TH STREET 1 Ersn Cntrl 503-639-4175 7600 E DOUBLETREE RANCH RD VANCOUVER,WA 98660 2 Fire Rated Eaves-Both STE 1 Sides SCOTTSDALE,AZ 85258 PHONE: PHONE: 360-695-7700 FAX: Total Fees: $32,292.71 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. Y u may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344..� Issued By: Permittee Signature: C�rr_- Qir/9l 'e-4741'al Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. FOR OFFICE USE ONLY—SITE ADDRESS: This form is recognized by most building departments in the Tri-County area for transmitting information. Please complete this form when submitting information for plan review responses and revisions. This form and the information it provides helps the review process and response to your project. City of Tigard • COMMUNITY DEVELOPMENT DEPARTMENT II Letter Transmittal a e ter T U G A R D 13125 SW Hall Blvd. • Tigard, Oregon 97223 • 503.718.2439 • www.tigard-or.gov TO: Tom H. DATE RECEIVED: DEPT: BUILDING DIVISION RECEIVED FROM: Angela Grajewski APR 3 2017 CITY OF TIGARD COMPANY: Polygon Northwest BUILDING DIVISION / /' PHONE: 971-212-2144 By: RE: 17407 SW Shadow Trails ST MST2017-00008 (Site Address) (Permit Number) River Terrace Northwest Lot 127 (Project name or subdivision name and lot number) ATTACHED ARE THE FOLLOWING ITEMS: ies ,,k copies: X1`1 0 Additional set(s) of plans. 3 Revisions: /l 0 Cross section(s) and details. 0 Wall bracing and/or lateral analysis. 0 Floor/roof framing. 0 Basement and retaining walls. 0 Beam calculations. 0 Engineer's calculations. 0 Other(explain): REMARKS: Please pay fees owed with Trust Account. add due to terrain fa-6P eerVtr" ... OR CE USE O ' ..;. Routed to Pt Technician: Date: 6 / Initials: fi Fees Due: [ es ❑No ee I)esc ption: t Due• Special Instructions: Reprint Permit(per PE): Yes n No Done Applicant Notified: IDate: '- / Initials: !S I:\Building\Forms\TransmittalLetter-Revisions.doc 05/25/2012 , w • City of Tigard • f 4 COMMUNITY DEVELOPMENT DEPARTMENT l_ �,A n Building Permit Review — Residential Reith ~..1: 4f.a0c.:i:tNt .++:iu4;,vi:.kiai,.rdo sWittsrb»iLt..1F" ...• 01,4Y cas' :,.. ictai&,;.,4' C..,mss,r.44, 76i.JR74S,,,,, Building Permit #: /'I„ j / 7 — ee )Q e Site Address: / I/ 9 SIO gkcii(94, 7i/ -7 Project Name: kkee - ` .cac._ A tueS- Lot#: /Q (New dwelling=subdivision name;Addition or Alteration=last name of owner) Planning Review _ ' p Proposal: &J'a & not ) T 11' j�Cvff o (tour/ . erify site address/suite#exists and active in permits tem. ! River Terrace Neighborhood 0 No Yes,See River Terrace Review Addendum Attached Si Plan Elements: ee(3)copies of site plan T. ': ting structures on site to plan must k on 8-1/2"x 11"or 11 x 17"paper ! ootprint of new structure(including decks)with finished :loge to scale(standard architect or engineer scale) P•or elevations Orth arrow ri Utility locations(required for new,may apply for additions) eaddress,project or subdivision name and lot number P.1 L, .tion of wells/septic systems .licant information(name and phone number) ■ :o. ting trees to be retained with drip line,and tree , ,,t dimensions and building setback dimensions rotection measures TA Lot area,building coverage area,percentage of coverage and et tree size,type and location ' pervious area(applicable if R-7,R-12,R-25&R-40) tet names P"roperty corner elevations(2 foot contour lines if more than 4 foot differential) lean Water Services—Service Provider Lett (lot platted prior to 9/10/1995): vceilequired: 0 Yes,applicant was notified No Received: 0 Yes 0 No Public FacilitiyiImprovement(PFI)Permit utred: V Yes,applicant was notified 0 NoApplied For: Yes ❑ No,stop intake d Use Case#: �ap — .S �� C^ + OII oning. i2_- CP equired Setbacks: Front Rear Jo Side Street Side OR Garage cQ(} riadscape Requirement 0 % •nt Coverage Maximum: 0_ % / / 1l rd Building Height Maximum Height Actual Height <Q(Q Q II e' isual Clearance rA Easements skive Lands: 0 Yes ltl No Type Urban Forestry Plan 0 Conditions"Me ''priorr o issuance of buildi9g permit Notes: ntir!4iE7ns e j� L� pi7ir- pe is / .Slt c4._ Approved By Planning: c—�,,, '41111111,� // Date: .62 22- Revisions 2Revisions(after Building Submittal only) Reviewer. r€.Gl Aai rDate Revision 1: Approved 0 Not Approved AL. I"SCG+If lr te.S) 414 (n _ Revision 2: 0 Approved 0 Not Approved , Revision 3: 0 Approved 0 Not Approved l:\Building\Fonns\BldgPermitRvw_RES 091216.docx w Building Permit Submittal Original Submittal Date: 4a ,IE: Site Plans: # _ Building Plans: # ,..4 Building Permit#: 113-'Enter building permit#above. ' Workflow Routing. EL-Planning El--"Engineering 'Permit Coordinator --Building Workflow Sign-off: Coign-off for Planning(include notes from planning review) Route Application Documents: C-Engineering (1)copy of permit application,(1)site plan,(1)building plan and original plan review routing form. Er-Building: original permit application,site plans,building plans,engineer and beam calculations and trust details,if applicable,etc. 1 Notes: ,� By Permit Technician: .. Date: VV/7 - .v_na-W-.1�L�i'.?f,sa7Fi•Yet4w.x'cS�;�fR'.S.ILYtX: .. Engineering Review ...X-Slope at building pad: .,2j, ,r, ()Conditions"Met"prior to issuance of building permit J vO f ❑ Easements (encroachments)per engineering conditions of approval and plat ❑ Water Quality/Quantity Facility: Assess Water Quality Fee in-lieu: 0 Yes 0 No Assess Water Quantity Fee in-lieu: 0 Yes 0 No LIDA Facility on lot 0 Yes 0 No O NOT Approved by Engineering: Date: Notes: Approved by Engineering: / 2 7 Date: Revisions(after Building Submittal only) )12,Ter �!Date _ Revision 1: Approved 0 Not Approved Revision 2: Approved 0 Not Approved Revision 3: 0 Approved ❑ Not Approved Permit Coordinator Review ❑ Conditions"Met"prior to issuance of building permit (15PApproved,NOT Released: Date: ///)// Revisions(after Building Submittal only) Revision Notice 1: Date Sent to Applicant: Revision Notice 2 Date Sent to Applicant: Revision Notice 3: Date Sent to Applicant SDC Fees EnteredWash Co Trans Dev Taxes 0 N/A Tigard Trans SDC: Yes 0 N/A Parks SDC: 0 N/A i`B to Issue Permit ,Yes - i ---- Approved by Permit Coordinator: �/ 7���"'aie: / / r/ 9 I:\Building'arms\BldgPermitRvw_RES_0912I6.docx V -7/` City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 Location: Inspection Date: 17407 SW SHADOW TRAIL ST, BEAVERTON, October 10, 2017 at 10:27:14 OR, 97007 AM Record Type: Record ID: Residential - Master Permit MST2017-00008 Inspection Type: Inspector: 399 Plumbing final Aaron Cillo-Gobel Result: PASS Comments: Water pressure = 50 psi Violation Summary: Inspector Contractor City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 Location: Inspection Date: 17407 SW SHADOW TRAIL ST, BEAVERTON, October 10, 2017 at 10:28:29 OR, 97007 AM Record Type: Record ID: Residential - Master Permit MST2017-00008 Inspection Type: Inspector: 699 Mechanical final Aaron Cillo-Gobel Result: PASS Comments: Corrections completed. A/C installed at this time. Violation Summary: Inspector Contractor