Loading...
Report INTELLIKNIGHT FIRE ALARM CONTROL PANEL am A.51erA04. wri,, M31 i ll i I 0 11'' 1 1 I I I 0 r i i^ ... �It �b Mi+Wu enMan...n aaw..e D,.w.r .N.N. rn .aw ....,mow+ Mwe Ala.. Mclaca Wt .AetresMOl*c .nM A.Mon M I ,� oJ5 an Mm. p r ,w,,,.. I + alt-Assamate Mt den. SA.M.6 SM. IMIAllt .III ,,t=to, cammY"au. ..=, e z sem.. rz" = Rei.emu I inters nM.., I ~ rm eM Moa,.. CO lilt 01 1111,;-UPI mill S 1 11.1 a - ' : "ame 5496 Mt.. CNA.. MlNat .4.0 Ml;.. weave Mon.M.. illteiweaMt'm. .o.a. Cant Ma�a ewe ract M.o. '�tl, c0e w...o,..w.....u, Been Oeta.N. AC.... Module mett�M 5808 Specifications Protected Premises Unit; &Water Deluge Miscellaneous Accessories Electrical Releasing Service. Suitable for automatic, 5660 Silent Knight Software Suite PrimaryAC: 120 VRMS at 50/60 Hz, manual,waterflow, sprinkler supervisory (DACT non-coded)signalling services. PC base software for FACP 2.75A UL Listed programming. Upload and view panel Total Accessory Load: 6A @ 27.4 CSFM 7165-0559:0142; account information, event history, and VDC MEA 429-92-E Vol.XIV detector status. Notification Power: 6A @ 27.4 VDC, OSHPD(CA)OSP-0065-10 5670 Silent Knight Software Suite power-limited End-user facilitymanagement software Standby Current: 170 mA S-BUS Accessories allows viewing of detector status and Alarm Current: 365 mA 5860/R Remote Fire Annunciator event history via modem or direct Notification&Auxiliary Circuits: Features the same 80 character backlit connection. 3A @ 27.4 VDC per circuit,power- LCD display keypad and firefighter's key limited switch as the 5808. 5860 is gray and Plex-2 Door Battery Charging Capacity: 5860R is red. Dead front cabinet door with clear 7.0 35 AH window to limit access to the FACP. 5496 Intelligent Power Module Battery Size: 18 AH max. allowed in A 6 amp notification power expander that RBB FACP. Larger capacity batteries can provides four additional power-limited Remote Battery Box Accessory be housed in an RBB accessory notification appliance circuit outputs. Cabinet. Use if backup batteries are cabinet too large to fit into FACP cabinet. 5880 LED/IO Module Dimensions: 16"W x 10" H x 6" D Physical Features 40 LED outputs, 8 normally open (406 mm W x 254 mm H x 152 mm D) Flush Mount Dimensions: dry contact inputs and one piezo output. - 14.5"W x 24.75" H x 3.5" D SK-SCK (36.8 W x 62.9 H x 8.73 D cm) 5865-3 and 5865-4 Seismic Compliance Kit Remote LED Annunciator Overall Dimensions: Features 30 programmable LED (15 red SD and SK Devices 16"W x 26.4" H x 4.65" D and 15 yellow)outputs and a piezo See the specification sheets listed (40.6 W x 67 H x 11.8 D cm) sounder. The 5865-4 adds a silence and below for a complete listing of the SD Weight: 28 lbs. (12.8 kg) reset switch to the package. and SK devices. Color: Red 5824 Serial/Parallel Printer 53624 SD Devices data sheet Telephone Requirements: Interface Module 53623 SK Devices data sheet FCC Part 15 and Part 68 approved Provides one parallel and one RS-232 Type of Jack: RJ31X(two required) serial port for connecting a printer to 5808. Approvals Use to print a real-time log of system NFPA 13, NFPA 15, NFPA 16, NFPA events, detector status reports, and event 70, & NFPA 72: Central Station; history. Remote Signalling; Local Protective 5883 Relay Board IntelliKnight&JumpStart are Registered Signalling Systems;Auxiliary Features 10 general purpose Form C Trademarks of Silent Knight Flexput is a relays. Used with 5880 module. Trademark of Silent Knight it SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA keep our product information up-to-date and accurate.We cannot cover all NII KNIGHT specific applications or anticipate all requirements.All specifications are 350386 Rev. L subject to change without notice. For more information,contact Silent Knight ©2013 Honeywell International Inc. by Honeywell 12 Clintonville Road, Northford,CT 06472-1610.Phone: (800)328-0103, Fax: (203)484-7118.For Technical Support,Please call 800-446-6444. www.silentknight.com INTELLIKNIGHT ACCESSORY OSILENT 5860 Remote Annunciator KNIGHT by Honeywell Bring the power to control an IntelliKnight - fire alarm control panel to every area within your facility Now you can operate and program your IntelliKnight system from up to twelve locations throughout your facility. The 5860 remote annunciator provides the same advanced, easy-to-use interface found on the IntelliKnight panel's built-in annunciator. The 80-character display and ergonomically designed keypad allow for simple and error-free system operation.All operations—including reset, silence, detector status checking, fire drill, and programming—are identical. Access to the system is through a firefighter's key or an access code. For security, a special installation code is needed for programming functions. The 5860 connects to the IntelliKnight panel via the RS-485 system bus. Wire runs can be up to 6000 feet from the panel. For more information about the IntelliKnight system, or to locate your nearest source, please call 1-800-328-0103. Description • Available in red or light gray Features include an 80-character • Support for simultaneous use of backlit LCD providing easy-to- multiple 5860s understand system messages. The • RS-485 interface to panel annunciator is ergonomically • Operation and appearance is designed with over-sized buttons identical to 5860 built-in for the most frequently used annunciator g features, like Reset and Silence. • On-board piezo sounder audibly , In addition to status messages indicates alarms, troubles, and ' ^ ; supervisories • displayed on the LCD, there are . Five status LEDs for alarm, five LEDs for alarm, supervisory, supervisory, trouble, silence and trouble, silence, and AC power AC power conditions status. 5860 • Wiring lengths up to 6000 ft. from The annunciator is available in gray the FACP (depending on wire Environmental to match virtually any decor and gauge and number of devices on Operating Temperature: 32°F– red for applications where the SBUS) 120°F (0°C–49°C) •annunciator must stand out. The UL listed, complies with NFPA 72 Humidity: 10% –93% non- annunciator enclosure can be CSFM approved condensing surface or flush mounted.A trim Electrical Specifications Compatibility ring kit is available for surface Operating Voltage: 24 VDC The 5860 is compatible with the mounting. Standby Current: 20 mA max following FACP's: Features Alarm Current: 25 mA • 5820XL Addressable Fire Control • 80-character backlit LCD display Wiring Distance: 6,000 max. from Panel (4 lines with 20 characters on FACP (depending on wire gauge • 5820XL-EVS Fire Control Panel each line) with Emergency System and number of devices on the 9 Y Voice y em • Tactile and audible feedback SBUS) • 5808 Addressable Fire Control • Accepts user codes or fire Panel fighter's key Mechanical Specifications • Larger keypad buttons for system Physical 9.1"W x 7.4" H x 1.5" D • 5700 Addressable Fire Control reset and silence (23.1 W x 18.8 H x 3.8 D cm) Panel • Install up to twelve 5860s per Shipping Weight: 2.8 lbs (1.3 kg) 5820XL/EVS or 5808 system Color • Install up to eight 5860s per 5700 5860R: Red PN 350224 Rev G system 5860: Gray ©2014 Honeywell International Inc INTELLIKNIGHT ACCESSORY 5860 Remote Annunciator Engineering Specifications The main control must have a built-in annunciator and must support up to 12 remote annunciators. Remote annunciators shall have the same control and display layout so as to match the appearance of the built-in annunciator. Remote annunciators shall be available in two colors, red or light gray. Remote annunciators shall have identical functionality and operation as the built-in annunciator.All annunciators must have an 80-character LCD display and must feature five LEDs for: General Alarm, Supervisory, System Trouble, System Silence, and System Power. All controls and programming keys are silicone mechanical type with tactile and audible feedback. Keys have a travel of.040 inches. No membrane style buttons will be permissible. The annunciator must be able to silence and reset alarms through the use of a code entered on the annunciator keypad or by using a firefighter's key. The annunciator must have two levels of user codes that will limit the operating system programming to authorized individuals. The control panel must allow all annunciators to accommodate multiple user input simultaneously. Wire Runs Up to 6000 Feet From FACP II' .t.':::* . . SB US { # P 6860 6860 6860 • Up to 12 5860s Per IFP-100/ECS or IFP-1000/ECS System •Up to Eight 6860s Per 6700 System Compatible IntelliKnight FACP Listings Ordering Information NFPA 72; UL Listed; 5860R Remote Annunicator four line LCD CSFM 7170-0559: 135; annunciator with 20 characters per line. MEA 429-92-E Vol. IX; Red FM Approved 5860 Remote Annunciator four line LCD annunciator with 20 characters per line.' Gray Accessories 5860TR Red Trim Ring for surface mounting 5860TG Gray Trim Ring for surface mounting SILENT This document is not intended to be used for installation purposes.We try to keep our product information up-to-date and accurate.We cannot cover all KNIGHT specific applications or anticipate all requirements.All specifications are ,R subject to change without notice. For more information,contact Silent Knight by Honeywell 12 Clintonville Road, Northford,CT 06472-1610. Phone:(800)328-0103, Fax: (203)484-7118. For Technical Support, Please call 800-446-6444. www.silentknight.com Assembled in America P POTTER PSN SERIES ® The Symbol of Protection POWER SUPPLY UL,cUL,CSFM Listed • PSN-64 has 6 amps regulated with 4 Outputs • PSN-106 has 10 amps regulated with 6 Outputs • Outputs Rated at 3 amps maximum each • May be configured as up to three class"A"Style"Z"notification circuits tom, • 3 amp,24 VDC programmable output power P • Supervised Battery Charger:27.3 @ lA(supports 7-55 All batteries) • Easy to install cabinet with leveling mounts and key lock 0. • Wiring knockouts provided on sides and top of cabinet • Two Trouble Relays(5A at 30VDC) General System Trouble(programmable for AC delay) Low AC Trouble with optional delay settings • Diagnostic LED's Patent pending Status LED's for Active NAC and NAC trouble conditions Status LED's for Earth Fault(Amber),AC(Green),Battery Fault(Amber) • Trouble Memory feature captures troubles which have previously restored mot COUS ff +y • Synchronized notification appliance circuits ` 1 Potter/AMSECO®,Wheelock®,Gentex®,System Sensor® LISTED Eft, S2930 7315-0328:0189 • Configurable output circuits(DIP switch sets options for each circuit) • 15 mA at 8-33 VDC input trigger Product includes a 5 year warranty • Reference EOL allows 2K—27K EOL value to be used • Quadrasync provides panel wide synchronization of same or multiple brands Dimenions: 16 1/8"W x 16 3/4"H x 3 1/2"D • PassThru mode allows the Outputs to match the Input Signal Electrical Specs: Stock Number:3006436 PSN-64 Red Enclosure • 120/240 VAC 50-60 Hz input 3006437 PSN-106 Red Enclosure • 5.1 Amps @ 120 VAC or 2.5 Amps @ 240 VAC 3006446 PSN-106 Black Enclosure • Standby Current 60 mA • Alarm Current 200 mA* *no external load Description The PSN series of notification power supplies offers reliable notification Sensor®strobe devices.Each output can be configured the same sync power with unprecedented versatility.The power supplies offer either protocol or set independently. 6 or 10 amps of continuous power through 4 or 6 outputs respectively. In addition,the panel has an input PassThru mode allows the outputs Each output is rated at 3 amps and it may be used continuously without to follow the input signal and sync up the input flash.The panel will any derating. recognize the type of input being supplied and pass this through to the The power supply operates on either 120 VAC or 220 VAC power input outputs with the same pattern.This input pass through can be selected and has a regulated 24 VDC output.In addition,the panel can charge on each output independently. up to 55 All batteries and leads the industry in housing up to 18 AH The power supply contains simple dipswitch programming and LED batteries.The cabinet is constructed out of 18 gauge cold rolled steel and indications providing the installer indications of the operation and the has a durable red powder coat finish.In addition,a key lock is provided ability to correct any faults.A Trouble Memory is provided to allow an for securing the door.Ample electrical knockouts are provided on the installer to review past troubles and make the necessary repairs.Each sides and the top,allowing the installer options for running wires and output has an LED to pin point the exact circuit where a problem may maintaining the correct separations. have occurred.Relays are provided for monitoring the general system The power supply offers an industry leading Quadrasync function that and AC failure. allows for multiple strobe circuits of different brands to be synchronized Each output and be independently configured for various applications to flash at the same time.The panel can have four different brands each and installations.Each output can be independently configured for Class connected to its own circuit and all of the strobes flash together. A or Class B operation,constant power,ANSI Temporal Code 3,Single, Each output can independently be configured to provide one of Multiple or Combo Inputs or Door Holder Power. four synchronizations or steady power. This provides unequivocal flexibility in new and retrofit installations.The panel can be configured to synchronize Potter/AMSECO®, Gentex®, Wheelock® and System Potter Electric Signal Co.,LLC•St.Louis,MO•Cust Service: 866-240-1870•Tech Support: 866-956-1211 •Canada 888-882-1833•www.pottersignal.com PRINTED IN USA MKT.#8910013-REV C2 PAGE 1 OF 2 11/12 . , P POTTER PSN SERIES ® The Symbol of Protection POWER SUPPLY PSN-106 Wiring Diagram N° 120/240 VAC GND FAULT • N 6i Jumper Position DETECT ENABLE 120VAC 50Hz-60Hz ON OFF 240VAC 50Hz-60Hz Black Connect to separate White unswitched AC circuit Ground status LED's I-0—F gt- — # ' NAC] NAC NAC3 NAC4 NAC5 NAC6 DC PWR •87 S8 t u J O [BBBBB89B1[BBBOBBBB] — H N CIo o OE* 0 C I COMM• Fuse I o BBBBB'sz lit [J7 I II II [s] ❑ 0 ° ov @II Factory Installed ° ° 0 o 1.I.III!RRs4 Interconnect. • AC Power • I MOP S5 Low Battery Co • God Fault • Comm I rBBBBBIs6 • 8 CI ORO Butk Options I I O Akek I0 I 1 0 0 - . + NAC3 - - .5 NAC6 P R REF I- 1N2 0 + - + - + - + - *+ - + _ + FDI - FIB - +FM NC COM NO NC CMy Balry+ O Common relays are Battery Optimal E.O.L. non-power limited. '°, Reference E.O.L. DC Power Trigger . Battery connection(non-power limited). Note:PSN-64 and PSN-106 draw 15 mA when polarity reverses and the power use two(2)12V batteries connected in series. supply is triggered.There is no current draw in Standby Mode. Engineering Specification The contractor shall supply and install the Potter PSN power supply.The assemblies.The LEDs shall have distinct flash patterns to provide further power supply shall operate on either 120 or 240 VAC input.The panel indication ofthe troubles present.The panel shall have selectable Trouble shall be capable of continuous load power without any degradation to Memory to provide the installer an indication that a past trouble existed the main supply or the distribution board.The cabinet shall be capable of on a circuit for diagnostic purposes. housing up to 18 All batteries and the panel shall be capable of charging Each output of the power supply shall be capable of 3 amps of continuous up to 55 AH batteries in an external cabinet. power without degradation over time.The power supply shall provide for The panel shall have dip switches for simplistic configuration of the multiple circuits of strobe appliances.The power supply shall synchronize system and LEDs to provide visual indication to the installer of the status the flashes of any of the above listed strobe appliances on a per circuit of the system.The dip switches shall allow for AC power delay selection, basis.Up to four different strobe circuits may be connected and all of Class A/B operation per output,Door Holder Power options,constant the strobes shall flash in unison as required by UL 864.In addition to auxiliary power,trigger input type,ANSI Code 3 Temporal Code,Pass this Quadrasync feature, the panel shall allow any of the four above Thru(input tracking),Potter/AMSECO®sync,Gentex®Sync,System mentioned sync patterns as an input and pass this signal through and Sensor®Sync or Wheelock®sync.The LEDs shall provide indication synchronize the outputs to match the input flash pattern. of communication between the power supply and distribution circuit PRINTED IN USA MKT.#8910013-REV C2 PAGE 2 OF 2 11/12 INTELLIKNIGHT ACCESSORY II SILENT SK-Minimon KNIGHT by Honeywell Intelligent Mini Monitor Module The SK-Minimon addressable mini monitor modules for use with Silent Knight IntelliKnight fire alarm control panels (FACP). The SK-Minimon is designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. For more information about the IntelliKnight system, or to locate your nearest source, please call 800-328-0103. Description The SK-Minimon is an addressable monitor modules for use with the IntelliKnight fire alarm control panels (FACPs). The SK-Minimon acts as an interface to contact devices, such as waterflow F ; switches and pull stations. •The SK-Minimon supports Class B —� k„ supervised wiring to the load device. Conventional 4-wire smoke Baa fi . detectors can be monitored for alarm and trouble conditions The SK-Minimon can be mounted t in a single gang junction box directly behind the monitored device. Its small size and light SK-Minimon weight allow it to be installed without rigid mounting Specifications Compatibility requirements. The SK-Minimon is compatible with Electrical Features Standby Current: 400 uA max @ the following IntelliKnight Systems: • Single contact monitor 24 VDC with comm. 5820XL • SK-Minimon support for Class B Voltage Range: 15 - 32 VDC 5820XL-EVS (Style B) contact monitor wiring End of Line Resistance: 47 k Ohms 5808 5700 • Small and lightweight size allows Physical 5600 (Rev 2.0 or higher) for flexible mounting options Dimensions: SK-FFT • Rotary address switches for fast 2.75"W x 1.3" H x 0.5" D installation Weight: 1.2 oz (37 g) • UL listed Environmental Listings Operating Temperature: UL 32°F— 120°F (0°C—49°C) CSFM Humidity: FM 10%—93% non-condensing INTELLIKNIGHT ACCESSORY SK-Minimon Intelligent Monitor Module Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable monitor modules Silent Knight SK-Minimon. The modules shall be UL listed and compatible with Silent Knight's IntelliKnight FACPs. The SK-Minimon shall be installed inside a single gang junction box directly behind the monitored unit. 14150 1 2 ADDRESS 0 1 2 13 3 $ Compatible FACP 11 r 410 5 4 98 7 8 3 LOOP 9 8 7 6 TENS ONES 11_n rL(L - + + - 00 x c -<g; s — a 3 0 0 ° I - - I Other Devices Wiring the SK-Minimon SILENTEl This document is not intended to be used for installation purposes.We try MADE IN AMERICA to keep our product information up-to-date and accurate.We cannot cover KNIGHT all specific applications or anticipate all requirements.All specifications are FORM#350133 Rev E subject to change without notice.For more information,contact Silent ©2013 Honeywell International Inc by Honeywell Knight 12 Clintonville Road, Northford,CT 06472-1610 Phone:(800)328-0103, Fax:(203)484-7118. For Technical Support, Please Call 800-446-6444. www.silentknight.com I NTELLIKN IGHT ACCESSORY DSILENT SK-Relay KNIGHT ® Intelligent Relay Module by Honeywell The SK-Relay Module is intended for use in intelligent, two-wire systems where the individual address of each module is selected using the built in rotary switches. For more information about the IntelliKnight system, or to locate you nearest source, please call 800-328-0103. Description The SK-Relay is an addressable relay module for use with Silent Knight IntelliKnight series fire alarm control panels (FACPs). The SK-Relay allows a Silent Knight FACP to switch .;° discrete contacts by code command. The relay contains two isolated sets of Form C contacts, which operate as a DPDT u ., switch. No supervision is provided for the notification • appliance circuit. The SK-Relay contacts can be used for virtually any normally open or normally closed application. Each SK- SK-Relay Relay is programmed with a unique signaling line circuit (SLC) loop address. When an event occurs that controls the Installation SK Relay, the relay is triggered by the FACP. The SK-Relay mounts directly into a 4" square Features electrical box. The box must have a minimum • Two sets of Form C contacts depth of 2-1/8".A surface mount electrical box (System Sensor® PN SMB500) is available from • Rotary address switches for fast installation Silent Knight • Contacts are rated for a variety of amps (see Specifications) Compatibility • Panel controlled status LED that flashes green in normal The SK-Relay is compatible with the following state and is solid red in alarm IntelliKnight FACP's: 5820XL • Relay programming is completely flexible—can be mapped 5820XL-EVS to zone conditions 5808 5700 • Polling LED visible through the cover plate 5600 (Rev 2.0 or higher) • Attractive ivory cover plate • SEMS screws for easy wiring • UL Listed INTELLIKNIGHT ACCESSORY Model SK-Relay Intelligent Relay Module To Next Device — 4 If Any Wiring to Terminals 3—9 is Not Power + 4 Limited,the CB500 Barrier is Required.The CB500 Includes a Non-Power Limited Label, n n Which Must Be Placed Over the Power Limited '(2 0 c O _ _.J Terminal Information on the Name Plate Label. Relayte- Common 2 e •. . a ■i Normally Closed 2 e ;(`,fie I •<; Normally Open 2 7 2 Relay Common 1 •e "' 3 :] I •' — From Compatible FACP Normally Closed 1 e ; ` s ;; + or Previous Device Module Does Not Supervise {1 ° 0 Normally Open 1 Controlled Circuits `V U U Wiring the SK-Relay Module Specifications End-of-Line Resistance: not used Physical Standby Current: 300 pA max @ 24 VDC (one - Height: 4.65" communication every 5 sec with LED enabled) Width: 4.25" LED Current: 5.5 mA(with LED latched on) Depth: 1.1" SLC Loop Resistance: 4052 max. Shipping Weight: 6.3 oz (196 g) Relay Contact Ratings Electrical 3.0A @ 30 VDC resistive Operating Voltage: 15—32 VDC 0.9A @ 110 VDC resistive Current Draw: 6.5 mA max (LED on) 0.9A @ 125 VAC resistive Operating Current: 0.5A @ 125 VAC inductive (PF = .35) 230 pA(LED flashing) direct poll 0.7A @ 75 VAC inductive (PF = .35) 255 pA(LED flashing) group poll SILENT This document is not intended to be used for installation purposes.We try MADE IN AMERICA Ell FORM#350127 Rev D KNIGHT to keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are subject to change without notice. For more information,contact Silent by Honeywell Knight 12 Clintonville Road, Northford,CT 06472-1610 Phone: ©2013 Honeywell International Inc. (800)328-0103, Fax:(203)484-7118. For Technical Support, Please Call 800-446-6444. www.silentknight.com INTELLIKNIGHT ACCESSORY SILENT SK-Pull-SA and SK-Pull-DA KNIGHT Intelligent Pull Stations by Honeywell The SK-Pull-SA and SK-Pull-DA are a single action or dual action addressable fire alarm pull station for use with Silent Knight's IntelliKnight fire control panel. Extremely easy to operate, the SK-Pull-DA and SK-Pull-SA provide a fast and practical means of manually initiating a fire alarm signal. The IntelliKnight panel recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. For more information about the IntelliKnight system, or to locate you nearest source, please call 1-800-328-0103. Description The SK-Pull-SA is a single action pull station requiring only one motion to activate the station. The SK-Pull-DA is a dual action pull station requiring two motions to active the station. Both pull stations are designed to work with Silent Knight 10, PULL DOWN Intelliknight series fire alarm control panels (FACPs). Features • Installer can open station without causing an alarm condition 0 • Dual-color LED is visible through handle of station blinks green to indicate normal operation and remains steady red in an alarm condition SK-Pull-SA • Key operated test and reset lock using lock plate actuator • Key matches compatible FACP locks F • Meets the Americans with Disabilities Act Accessibility Guidelines (ADAAG) controls and operating mechanisms 1 PUSH IN guidelines (Section 4.1.3[13]) PULLDOWN • Meets ADA requirement for 5 lbs maximum pull force to active • Shell, door, and handle molded from durable LEXAN® Q s HKNI7 �• • Reliable analog communications for trouble-free operation • Braille text on station handle SK-Pull-DA • Handle latches in down position and the word Activated Compatibility appears, clearly indicating the station has been pulled The SK-Pull-SA and SK-Pull-DA are compatible • Rotary address switches for fast installation with the following IntelliKnight FACP's: 5600 • UL Listed, including UL 38, Standard of Manually Actuated 5700 Signaling System 5808 5820XL 5820XL-EVS INTELLIKNIGHT ACCESSORY Model SK-Pull-DA and SK-Pull-SA Intelligent Pull Stations Engineering Specifications The contractor shall furnish and install where indicated on the plans,Addressable Pull Stations, Silent Knight model SK-Pull-SA single action pull station or SK-Pull-DA, dual action pull station. SK-Pull-DA or SK-Pull-SA meet the ADAAG controls and operating mechanisms guidelines, and the ADA requirements for a 5 lb. maximum pull force to activate the pull station. i„ } Class A Class B i i Compatible FACP zi ',:v i7 N x.-.1 2 3 a i t 2 511 Nil H MQ w ClassA Wiring:— Class B Wlri,p: ,a„ . §- x' f. 1 Wiring SK-Pull-SA&SK-Pull-DA Pull Stations Specifications Electrical Operating Voltage: 15-32 VDC Physical Height: 5.5"(14 cm) Average Operating Current(LED flashing): 300 pA Width:4" (10.2 cm) Wire Gauge: Up to 12 AWG (3.1 mm2) Depth: 5.4 oz. (3.7 cm) Environmental Housing Material: LEXAN polycarbonate resin Operating Temperature 32°— 120°F(0°C—49°C) Bi-Colored LED: Humidity: 10%—93% non-condensing Blinking Green: Normal Steady Red:Alarm Accessories Switch: Single pole, single throw(SPST)normally open (N/O) BG-TR Optional trim ring. switch which closes upon activation of the pull station SB-I/O Surface backbox laSILEN•I, This document is not intended to be used for installation purposes.We try MADE IN AMERICA to keep our product information up-to-date and accurate.We cannot coverIG all specific applications or anticipate all requirements.All specifications are FORM#350135 Rev C subject to change without notice. For more information,contact Silent by Honeywell Knight 12 Clintonville Road, Northford,CT 06472-1610 ©2013 Honeywell International Inc. Phone: (800)328-0103, Fax: (203)484-7118. For Technical Support, Please call 800-446-6444. www.silentknight.com INTELLIKNIGHT ACCESSORY SILENT SK-Photo, SK-Photo-T De KNIGHT and SK-PhotoR by Honeywell Intelligent Photoelectric Smoke Sensors The SK-Photo is a photoelectric smoke detector, the SK-Photo-T is a photoelectric smoke detector with thermal and SK-PhotoR is a photoelectric detector with remote test capability. These plug in smoke detectors, with integral communication, provide features that surpass conventional detectors and are for use with Silent Knight IntelliKnight Fire Alarm Control Panels (FACPs). For more information about the IntelliKnight system, or to locate your nearest source, please call 800-328-0103. Description • Optional remote LED annunciator (System Sensor®PN RA100Z) SK-Photo and SK-Photo-T are plug-in • Plug-in mounting provides ease of type smoke sensors that combine a installation photoelectric sensing chamber with • Tamper-proof feature available on addressable analog communications. Hca Point ID capability allows each mounting bases , ,� ,.4 detector's address to be set with rotary • Listed for use in duct applications .' address switches, providing exact • Rotary address switches for fast detector locations for selective installation maintenance when chamber • UL Listed contamination reaches unacceptable • FM Approved411111‘,. .,:04, levels. SK Photo and SK-Photo-T have a Specifications unique optical sensing chamber that is Physical .. :.a ,, . engineered to sense smoke produced Height: 2.0"(5.0 cm) SK-Photo (Base included) by a wide range of combustion Diameter: 4.1" (10.4 cm)installed in sources. In the SK-Photo-T, dual B501 base Installation electronic thermistors add 135°F (57°C) thermal technology to maximize Electrical detection. Operating Voltage: 15-32 VDC The SK-Photo and SK-Photo-T plug Standby Current: into a compatible IntelliKnight-series The SK-PhotoR is a remote test detector base.The SK-PhotoR is a capable detector for use with the 300 pA @ 24 VDC Maximum remote test capable detector head DNR/DNRW duct smoke detector. (not Alarm Current: 6.5 mA @ 24 VDC max included within the DNR(W)duct included) (with LED on) smoke detector. EnvOperating Compatibility Operating Temperature Features SK-Photo: 32°—120°F(0°C—49°C) SK-Photo, and SK-Photo-T are • Sleek, low-profile design SK-Photo-T: 32°— 100°F(0°C—38°C) compatible with the following detector • Base included Humidity: 10%—93% non-condensing bases: • Reliable analog communications for Other Ratings B210LP 6"base(included) B501 2 wire base trouble-free operation SK-Photo-T Thermal: Fixed B224RB Relay base • Age resistant polymer housing temperature set point 135°F(57°C) B224B1 Isolator base • Dual electronic thermistor design on Velocity: 0—4000 fpm (0—20 m/sec) B200SR Sounder base the SK-Photo-T The SK-Photo, SK-Photo-T, and SK- • Superior EMI resistance for reliability PhotoR are compatible with the • Simple field cleaning for code following IntelliKnight FACPs: compliance 5820XL • Variety of mounting options to meet 5820XL-EVS any application 5808 5700 • Dual LED indicators for 360°visibility 5600(Rev 2.0 or higher) • Detector transmits signal to indicate maintenance is required INTELLIKNIGHT ACCESSORY Model SK-Photo, SK-Photo-T and SK-PhotoR Intelligent Photoelectric Smoke Sensors Engineering Specifications The contractor shall furnish and install where indicated on the plans, Intelligent photoelectric smoke sensors Silent Knight SK-Photo or SK-Photo-T with thermal. The combination detector head, and twist-lock base, shall be UL listed and compatible with Silent Knight's IntelliKnight fire control panels. The base shall permit direct interchange with SK-Photo or SK-Photo-T. Base shall be the appropriate twist-lock base part number B210LP (included). The PhotoR is a remote test capable detector for use with DNR(W)duct smoke detectors. (not included). The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SK-Photo shall automatically perform a functional test of the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. SLC IN OUT ;; �'rl. . Compatible FACP I I + — + RA100Z(Optional) eli:711N 1N1 ail raff r it:74 -...: ... / p ‘air,' ‘;_p.,. \pi / Class A Optional Wiring Wiring SK-Series Detector Mounting Bases c SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA KNIGHT keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are FORM#350118 Rev E subject to change without notice. For more information,contact Silent Knight ©2013 Honeywell International Inc. by Honeywell 12 Clintonville Road, Northford,CT 06472-1610 Phone: (800)328-0103, Fax:(203)484-7118. For Technical Support, Please call 800-446-6444. www.silentknight.com INTELLIKNIGHT ACCESSORY SILENT SK-Heat, SK-Heat-HT KNIGHT and SK-Heat-ROR by Honeywell Addressable Thermal Heat and Rate-of-Rise Detectors The SK-Heat, SK-Heat-HT, and SK-Heat-ROR are plug in thermal detectors, with integral communication, that provide features that surpass conventional detectors. These thermal detectors are for use with Silent Knight IntelliKnight series Fire Alarm Control Panels (FACPs). IntelliKnight heat detectors are an essential component in virtually any IntelliKnight installation. The IntelliKnight panel recognizes each detector by its specific address, so precious seconds are not wasted in determining location of an alarm. Description • Detector transmits signal to SK-Heat, SK-Heat-HT and SK- indicate maintenance is required Heat-ROR are intelligent sensors • Plug-in mounting provides ease that utilize a state-of-the art of installation thermistor sensing circuit for fast • Optional remote LED annunciator response. Sensitivity is (System Sensor® PN RA100Z) continuously monitored and • Tamper-proof feature available on reported to the FACP. Point ID capability allows each detector's mounting bases address to be set with rotary • Rotary address switches for fast address switches, providing exact installation SK-Heat (base included) detector locations for selective • UL Listed SK-Heat-ROR: Rate-of-rise maintenance when chamber contamination reaches Specifications detection 15°F/min (8.3°C/min) unacceptable levels. Physical Compatibility Height: 2.0" (51 mm) SK-Heat is a fixed temperature Diameter: 6.1" (155 mm) installed The SK-Heat, SK-Heat-HT and SK- sensor that uses a thermistor Heat-ROR are compatible with the sensing circuit to produce 135°F in B210LP base following detector bases: (57°C)fixed temperature alarm. Shipping Weight: 4.8 oz (137 g) Electrical B210LP 6" base (included) SK-Heat-HT is a variable high B501 2 wire base temperature detector that provides Operating Voltage: B224B1 Isolator base high temperature detection at 15 to 32 Volts DC Peak B224RB Relay base 135°F - 190°F. (57°C -88°C) Standby Current: B200SR Sounder base 300pA @ 24 VDC SK-Heat-ROR is a rate-of-rise The SK-Heat-HT and SK-Heat- temperature sensor with 135°F LED Current: 6.5 mA@ 24 VDC ROR are compatible with the (57°C)fixed temperature alarm. Environmental following IntelliKnight FACP's: Features Operating Temperature 5820XL SK-Heat & SK-Heat-ROR: 5820XL-EVS • Reliable analog communications _4°- 100°F (-20°C—38°C) 5808 for trouble-free operation 5700 • Age resistant polymer housing SK-Heat-HT: -4°— 150°F (-20°C—66°C) The SK-Heat is compatible with the • Innovative thermistor sensing following IntelliKnight FACP's: circuit Humidity: 10% —93% • Superior EMI resistance for noncondensing 5820XL 5820XL-EVS reliability Thermal Ratings 5808 • Variety of mounting options to SK Heat: Fixed temperature alarm 5700 meet any application 135°F (57°C) 5600 (Rev 2.0 or higher) • Dual LED indicators for 360° SK-Heat-HT: High temperature heat visibility sensor 135°F - 190°F (57°C - 88°C) INTELLIKNIGHT ACCESSORY Model SK-Heat, SK-Heat-HT, SK-Heat ROR Addressable Thermal and Rate-of-Rise Thermal Detectors Engineering Specifications The contractor shall furnish and install where indicated on the plans, Intelligent Thermal Sensor Silent Knight Model SK-Heat, SK-Heat-HT or SK-Heat-ROR. The base included shall be B210LP. The Heat detector shall have a flashing status LED for visual supervision. When the detector is activated, the flashing LED will latch on steady at full brilliance. The detector may be reset by actuating the control panel reset switch. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field removable when not required.Voltage and RF/transient suppression techniques shall be employed to minimize false alarm potential. SLC".. IN OUT w,r.4:4,' , Compatible FACP 111 RA100Z(Optional) 11111111111.mm-asi =II 716, t� �i. ivy L i ■ ■ Class A Optional Wiring Wiring SK-Series Detector Mounting Bases Accessories M02-09-00-Test Magnet with Telescoping Handle. RA100Z-Remote LED Annunciator. XP-4-Extension Pole for XR2B. Extends from 5—15 ft. RMK400-Recessed Mounting Kit. Provides low profile for use with T55-127-000-Detector Removal Head. 8501. XR2B-Detector Removal Tool.A removal and re-placement tool for BCK-200B-Black Detector Kit. For SK-series detectors. SK plug-in detectors. Includes the T55-127-000. *Unless otherwise noted,specifications apply to all SK thermal M02-04-01 -Replacement Test Magnet. detectors. SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA keep our product information up-to-date and accurate.We cannot cover all KNIGHT specific applications or anticipate all requirements.All specifications are subject FORM#350120 Rev. E to change without notice. For more information,contact Silent Knight 12 ©2013 Honeywell International Inc. by Honeywell Clintonville Road Northford, CT 06472-1610 Phone:(800)328-0103, Fax: (203)484-7118. For Technical Support, Please call 800-446-6444. www.silentknight.com DN-60611:A Wheelock® ExcederTM NOTIFIER Horns and Strobes by Honeywell Audio/Visual Devices General The Wheelock® ExcederTM Series of notification appliances feature a sleek modern design and numerous features includ- ` ing eight candela options in one appliance, low current draw, no tools needed for setting changes, 12/24 VDC operation, universal mounting base and multiple mounting options. Models with an audible feature 3 sound settings (90, 95, 99400* Wall dB).All switches to change settings can be set without the use of a tool and are located behind the appliance to prevent tam- re pering. Wall models feature voltage test points to take read r • ings with a voltage meter for troubleshooting and AHJ • F rrz F inspection. �� Ceiling The Wheelock®ExcederTM Series of wall and ceiling notifica- tion otifica tion appliances feature a Universal Mounting Base (UMB) �II1►, designed to simplify the installation and testing of horns strobes,and combination horn strobes.The separate universal mounting base can be pre-wired to allow full testing of circuit #, wiring before the appliance is installed and the surface is fin- ished. It comes complete with a contact cover for protection against dirt, dust, paint and damage to the contacts.The con- tact cover also acts as a shunting device to allow pre-wire test- General Notes ing for common wiring issues. The contact cover is polarized to prevent it from being installed • All candela ratings represent minimum effective strobe incorrectly and prevents the appliance from being installed intensity based on UL Standard 1971. while it is on the UMB.When the contact cover is removed the • Series Exceder Strobe products are Listed under UL Stan- circuit will show an open until the appliance is installed. The dards 1971 and 464 for indoor use with a temperature UMB allows for consistent installation and easy replacement of range of 32°F to 120°F(0°C to 49°C)and maximum humid- appliances if required.Wall models provide an optional locking ity of 93%(±2%)UL 464(85%UL 1971). screw for extra secure installation, while the ceiling models • Series Exceder horns are under UL Standard 464 for audi- provide a captive screw to prevent the screw from falling during ble signal appliances(Indoor use only). installation. • Product naming conventions: The Exceder line's model Features codes break down into easy-to-remember codes. HN = Horn, ST = Strobe, HS = Horn-strobe, C = Ceiling • Multiple voltages Mount,W=White,and R=Red.So"STRC"can be read as • Voltage test points for quick troubleshooting and easy spot- "Strobe, Red, Ceiling-mount."., and "HSW" is "Horn-strobe, checking(wall models only) white,wall-mount" • 3 audible settings(90,95,99 dB) • Refer to your fire alarm panel or power supply manual when 8 Candela settings calculating the number of devices allowed per circuit. • –Wall- 15/1575/30/75/95/110/135/185 Architects/Engineers Specifications –Ceiling-15,30,60,75,95, 115, 150, 177 The notification appliances shall be Wheelock Exceder Series • Finger-slide switches HS Audible Strobe appliances, Series ST Visual Strobe appli- • Sleek modern aesthetics ances and Series HN Audible appliances or approved equals. • Common base for wall and ceiling with 5 mounting options: The Series HS and ST Strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired)for Indoor –1-gang Fire Protection Service.The Series HS and HN Audibles shall –2-gang be UL Listed under Standard 464 (Fire Protective Signaling). –4 inch square All Series shall meet the requirements of FCC Part 15 Class B. –3.5 inch octagonal All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel –4 inch octagonal (FACP) with the ability to operate from 8 to 33 VDC. Indoor Compatibility and Requirements wall models shall incorporate voltage test points for easy volt- age inspection. • Synchronize using Wheelock Sync Modules,or panels with The Series HS Audible Strobe and ST Strobe appliances shall built-in Wheelock patented sync protocol. produce a flash rate of one flash per second over the Regu- • Compatible with UL"Regulated Voltage"using filtered VDC lated Voltage Range and shall incorporate a Xenon flashtube or unfiltered VRMS input voltage enclosed in a rugged Lexan®lens.The Series shall be of low • Strobes produce one flash per second over the Regulated current design.Where Multi-Candela appliances are specified, Voltage range. the strobe intensity shall have 8 field selectable settings at 15, DN-60611:A•05/03/2010—Page 1 of 2 15/75, 30, 75, 95, 110, 135, 185 candela for wall mount and shall been round and have a low profile with a diameter of 15, 30, 60, 75, 95, 115, 150, 177 candela for ceiling mount. 6.68" x 2.63" D. Series HNC ceiling shall have a diameter of The selector switch for selecting the candela shall be tamper 6.68"x 1.50"D. resistant.The 15/75 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is SYNCHRONIZATION required (e.g. ADA compliance). Appliances with candela set- When synchronization is required,the appliance shall be corn- tings shall show the candela selection in a visible location at all patible with Wheelock®Is SM, DSM Sync Modules, Whee- times when installed. lock® Power Supplies or other manufactureris panels with The audible shall have a minimum of three field selectable set- built-in Wheelock®Patented Sync Protocol.The strobes shall tings for dBA levels and shall have a choice of continuous or not drift out of synchronization at any time during operation. If temporal(Code 3)audible outputs. the sync protocol fails to operate, the strobe shall revert to a non-synchronized flash-rate and still maintain one flash per MOUNTING OPTIONS second over its Regulated Voltage Range.The appliance shall The Series HS Audible Strobe,ST Strobe and Series HN Audi- also be designed so that the audible signal may be silenced ble shall incorporate a patented Universal Mounting Base that while maintaining strobe activation when used with Whee shall allow mounting to a single-gang,double-gang,4"square, lock®synchronization protocol. 3.5" octagonal, 4" octagonal or 100mm European type back Standards and Codes boxes. Two wire appliance wiring shall be capable of directly connecting to the mounting base. Continuity checking of the Modules in this series comply with UL Standard 1971, UL entire NAC circuit prior to attaching any notification appliances Standard 464,California State Fire Marshal(CSFM),and ULC. shall be allowed. Product shall come with contact cover to pro- tect contact springs. Removal of an appliance shall result in a Agency Listings supervision fault condition by the Fire Alarm Control Panel These listings and approvals apply to the modules specified in (FACP).The mounting base shall be the same base among all this document. In some cases,certain modules or applications horn,strobe, horn strobe, wall and ceiling models. All notifica- may not be listed by certain approval agencies, or listing may tion appliances shall be backwards compatible. be in process.Consult factory for latest listing status. PHYSICAL SPECIFICATIONS • UL Listed:S5391 (Strobes);E5946(Horns, Horn/strobes). The Series HS and ST wall models shall have a low profile • ULC Listed measuring 5.24" H x 4.58" W x 2.19" D. Series HN wall shall . CSFM Listed:7125-0785:168. measure 5.24"H x 4.58"W x 1.6"D.The Series HSC and STC Specification & Ordering Information Model Strobe Candela 12/24 VDC Mounting Options Horn Strobes HSR 15, 15/75,30,75,95, 110, 135, 185 X Universal Mounting Base HSW 15,15/75,30,75,95,110,135,185 rX Vaunting Base HSRC 15,30,60,75,95, 115, 150, 177 X Universal Mounting Base SWC 15,30,60,75,95,11,5,150,1/7 X 4fk. 1op1,4g Base Strobes STR 15, 15/75,30,75,95, 110, 135, 185 X Universal Mounting Base STW 15, 15/75,30,75,95, 110, 135, 185 X Universal Mounting Base STRC 15,30,60,75,95, 115, 150, 177 X Universal Mounting Base 'STING '15,30,60,75,95,115,150,177 X Universal Mounting Base Horns HNR - X Universal Mounting Base HNW - X Universal Mounting Base HNRC - X Universal Mounting Base HNWC - X Universal Mounting Base *12 VDC models feature 15 and 15/75 settings NOTE:Due to continuous development of Cooper Wheelock products, specifications and offerings are sub- ject to change without notice in accordance with Cooper Wheelock Inc., dba Cooper Notification standard terms and conditions. Notifier®is a registered trademark of Honeywell International Inc. Exceder is a trademark and Wheelock®is a registered trademark of Cooper Notification. ©2010 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2-DN-60611:A•05/03/2010