Permit (78) INCITY OF TIGARD MECHANICAL PERMIT
�
'- COMMUNITY DEVELOPMENT Permit#: MEC2017-00239
13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 04/05/2017
�f � °t� g Parcel: 2S112DC00500
Jurisdiction: Tigard
Site address: 15889 SW 72ND AVE
Project: Red Hills Subdivision: FANNO CREEK ACRE TRACTS Lot: 40
Project Description: Install new return air duct &grilles for(4)new offices
Contractor: EXCEL HVAC INC Owner: PACIFIC REALTY ASSOCIATES LP
PO BOX 1188 ATTN: N PIVEN
CANBY, OR 97013 15350 SW SEQUOIA PKWY#300
PORTLAND, OR 97224
PHONE: 971-930-7194 PHONE:
FAX:
FEES
Specifics: Description Date Amount
Type of Use: COM Permit Fee 04/05/2017 $151.95
Class of Work: ALT Type of Const: Plan Review 04/05/2017 $37.99
Occupancy Grp: Occupancy Load: 12%State Surcharge-Mechanical 04/05/2017 $18.23
Stories:
Project Valuation: $3,200.00
Fuel Air Handlers
Fuel Types: Units<10000 cfm:
Gas Pressure: Units> 10000 cfm:
Furnaces Boilers&Compressors
Furnaces< 100K BTU: 0-3 HP:
Furnaces>=100K BTU: 3-15 HP:
Floor Furnaces: 15-30 HP:
Unit Heaters: 30-50 HP:
Vents w/o Appliances: 50 or Greater HP:
Air Conditioning:
Heat Pump:
Appliances
Vent Fans: Vent Systems: Total $208.17
Hoods: Comm Incinerators:
Required Items and Reports(Conditions)
Woodstoves: Gas Fireplaces:
Clothes Dryers: Other Mech Units:
Gas Outlets: Other Desc: return air grill
Duct Work: 1
Fire/Smoke Dampers:
This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other
applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of
issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon
Utility ,_' ilea..• Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. 'u may o• -in a copy of the rules
ort rect questions t. OU - . calling 503.232.1987 or 1.800.332.2344.
Is l ed By: i / /, ‘14_4_0 Permittee Signature: _ /
�W�
Call 503.639.4175 by 7:00 a.m.for the next available inspection ..-te. e
This permit card shall be kept in a conspicuous place on the job site until completion of the project.
Approved plans are required on the job site at the time of each inspection.
Mechanical Permit Application FOR OFFICE USE ONL\'
City Of Tigard 't:;;,., -,\ '' '`'' Received Iri M Ec co
S Date/By: y J 7 Permit No.:
III13125 SW Hall Blvd.,Tigard,OR 9223' Plan Review
Phone: 503.718.2439 Fax: 503.598.1960 Other Permit: (.u,/ /7-Op�j 7!
Date/By:
TI G A R D Inspection Line: 503.639.4175 / Date Read/B Jur s:
VI See Page 2 for
Internet: www.tigard-or.gov Notified/Method: Supplemental Information
TYPEF pj COMMERCIAL FEE* SCHEDULE - USE CHECKLIST
JI§ I fir 'If Il Mechanical permit fees*are based on the value of the work
El New construction Addition/alteration/replacement performed.Indicate the value(rounded to the nearest dollar)of all
❑Demolition ❑Other: mechanical materials,equipment,labor,overhead,and profit.
Value:$ . 1a00
C TEGORY OF CONSTRUCTION RESIDENTIAL EQUIPMENT/SYSTEMS FEES*
❑ 1-and 2-family dwelling Commercial/industrial ❑Accessory building For special information use checklist.
❑Multi-family 0 Master builder 0 Other: Description Qty. Ea. Total
JOB SITE INFORMATION AND LOCATION Heating/cooling:
Air conditioning 46.75
Job site address:/c F5--p2 S 1A., 7, w 0 I v£ Furnace 100,000 BTU(ducts/vents) 46.75
City/State/ZIP: 779,4 R r - Furnace 100,000+BTU(ducts/vents) 54.91
Suite/bldg./apt.no.: 1 Project name: D go_4 S
Heat pump 61.06
to()up Duct work 23.32
Cross street/directions to job site: Hydronic hot water system 23.32
Residential boiler(radiator or
hydronic) 23.32
Unit heaters(fuel-type,not electric),
in-wall,in-duct,suspended,etc. 46.75
Flue/vent for any of above 23.32
Subdivision: Other: 23.32
Lot no.:
Other fuel appliances:
Tax map/parcel no.: Water heater 23.32
r '<s.; ' DES-_ PTION OF WORGas fireplace/insert 33.39
-US7AL AJ 620 J��Al� OUGr 9.A/G��s Fluevent
23.32
ventfor water heater or gas
IG
fir
.;f7./e_ Czi)N VFFI cc 5 Log lighter(gas) 23.32
Wood/pellet stove 33.39
Wood fireplace/insert 23.32
Chimney/liner/flue/vent 23.32
ROPrERTY OWNER , ', - Other: 23.32
0 W_y * " Environmental exhaust and ventilation:
Name: pA ., U ,/ Range hood/other kitchen
equipment 33.39
Address:
Clothes dryer exhaust 33.39
City/State/ZIP: Single-duct exhaust(bathrooms,
toilet compartments,utility rooms) 23.32
Phone:(454‘ks) o2 .to 3 t� Fax:( ) Attic/crawlspace fans 23.32
'PLICANT .'" j Ol 'ACT . ' ON Other: 23.32
Fuel piping:
Business name:
$14.15 for first four;$4.03 for each additional
Contact name: �y y /..16.0 j Furnace,etc.
Address: Gas heat pump
Wall/suspended/unit heater
City/State/ZIP: Water heater
Phone:( ) Fax::( ) Fireplace
E-mail:
'/ Range
�C'!7!.+��ik y/`9 1✓�'CC�1/04C .f.JL�'"' Barbecue
ax ;x- 'C'''''''
C' CQNTRA" .�.R r ,: ,,,. ... Clothes dryer(gas)
Business name: G4.. ��
� �/ Other:
�IViO G Z� M CRAATI( L PE FES* m
Address: ?c /30I' ljg - C4.,../
8/ l Subtotal /57•9
City/State/ZIP: Minimum permit fee($90.00) ��
G'-4,J B , ,7a 1.
Phone:( ) 95/ _9 3„ 7)CZe' Fax:( ) Plan review(25%of permit fee) 37.99
State surcharge(12%of permit fee) /$.09.3
CCB lic.: a / y)y,s--" 5/61%, TOTAL PERMIT FEE c9.4f,4..!7
This permit application expires if a permit is not obtained within 180
days after it has been accepted as complete.
Authorized signa * Fee methodology set by Tri-County Building Industry Service Board
Print name: ( Date: t"'`Y l
/ , ..
I:\Buildng\Permits\MEC Permit _040113.doc 140-4-647T(11/02/COM/WEB)
Mechanical Permit Application - City of Tigard
Page 2 - Supplemental Information
Commercial& Multi-Family Fee Schedule:
Total Valuation: Permit Fee.
$0.00 to$500.00 Minimum fee$69.06
$500.01 to$5,000.00 $69.06 for the first$500.00 and
$3.07 for each additional$100.00 or
fraction thereof,to and including
$5,000.00.
$5,000.01 to$10,000.00 $207.21 for the first$5,000.00 and
$2.81 for each additional$100.00 or
fraction thereof,to and including
$10,000.00.
$10,000.01 to$50,000.00 $347.71 for the first$10,000.00 and
$2.54 for each additional$100.00 or
fraction thereof,to and including
$50,000.00.
$50,000.01 to$100,000.00 $1,363.71 for the first$50,000.00 and
$2.49 for each additional$100.00 or
fraction thereof,to and including
$100,000.00.
$100,000.01 and up $2,608.71 for the first$100,000.00 and
$2.92 for each additional$100.00 or
fraction thereof.
Note: All new commercial buildings require 2 sets of plans.
I:\Building\Permits\MEC_PermitApp_040113.doc 2
City of Tigard
13125 SW Hall Blvd.
Tigard, OR 97223 Tel: 503.718.2439
Location: Inspection Date:
15889 SW 72ND AVE, TIGARD, OR, 97224
Record Type: Record ID:
Commercial - Mechanical MEC2017-00239
Inspection Type: Inspector:
699 Mechanical final Chip Barnett
Result:
PASS - NoCofO
Comments:
Violation Summary:
Inspector Contractor