Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans
MI Mil Sc‘i see4c7 mitJUP,N 2 7 2i11 MiTeke' MiTek USA, Inc. 7777 Greenback Lane Suite 109 Citrus Heights,CA,95610 Telephone 916/676-1900 Re: PL1 5-264_UPPER Fax 916/676-1909 POLYGON The truss drawing(s)referenced below have been prepared by MiTek USA,Inc.under my direct supervision based on the parameters provided by Pacific Lumber&Truss Co.. Pages or sheets covered by this seal: R45124648 thru R45124656 My license renewal date for the state of Oregon is December 31,2016. Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others. , � ti) PR pp ,50 89782PE ' OREGON o) :1 PA UL. � - S 1 August 7,2015 Reivera,Mark The seal on these drawings indicate acceptance of professional engineering responsibility solely for the truss components shown. The suitability and use of this component for any particular building is the responsibility of the building designer,per ANSUTPI 1. Job Truss Truss Type Qty Ply POLYGON R45124648 PL15-264_UPPER F01 FLOOR GIRDER 1 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Fri Aug 07 13:53:53 2015 Page 1 ID:DFkz9p3tCrPAGZnVberKOtyJvgB3PgAmvXGRtLNnC7tbEC3UCrS8yFT1 vAVLj56CBygBiS 1 1-0-0 1 P-5431 I 1-2-0 1 1 0-7-6 1 Scale=1:25.0 1.5x3 11 1.5x3 11 1.5x3 11 1.5x3 11 1.5x3 11 1.5x3 11 1.5x3 11 1.5x3 11 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 • IN - e e - e e a a a a a e a / N / Nk c, a- r a ' a L 2r• •23 22 21 20 19 18 17 • 3x5= 3x5= 1.5x3 11 3x5= 3x5= 3x5= 1 7-0-14 17-7-14 18-2-141 14-4-4 7-0-14 0-7-0 0-7-0 6-1-6 Plate Offsets(X.Y)— 18:0-1-8.Edge].[19:0-1-8.Edge] LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) Udefl L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.30 Vert(LL) -0.11 20 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.54 Vert(TL) -0.17 20 >985 360 BCLL 0.0 Rep Stress Ina NO WB 0.39 Horz(TL) 0.04 16 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight:73 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 24=1249/0-2-8,16=676/0-4-4 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=1671/0,3-4=-1671/0,4-5=-2270/0,5-6=2270/0,6-7=-2493/0,7-8=-2493/0,8-9=-2423/0,9-10=-2423/0, 10-11=-1991/0,11-12=-1991/0,12-13=1193/0,13-14=1193/0 BOT CHORD 23-24=0/1222,22-23=0/2014,21-22=0/2425,20-21=0/2423,19-20=0/2423,18-19=0/2254,17-18=0/1635,16-17=0/646 WEBS 9-19=-273/0,2-24=-1712/0,2-23=0/628,4-23=-481/0,4-22=0/358,8-21=-226/359,14-16=-904/0,14-17=0/766, 12-17=-620/0,12-18=0/498,10-18=-384/0,10-19=-1/464 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)All plates are 3x4 MT20 unless otherwise indicated. 3)Provide mechanical connection(by others)of truss to bearing plate at joint(s)24. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)674 lb down at 1-1-12 on top chord. The design/selection of such connection device(s)is the responsibility of others. 6)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). LOAD CASE(S) Standard "\C4E PR QF�r0s 1)Dead+Floor Live(balanced):Lumber Increase=1,00,Plate Increase=1.00 Co ��G,INE /O Uniform Loads(plf) y Vert:16-24=-8,1-15=-80 '9 Concentrated Loads(Ib) CC. 89/$2PE f Vert:2=674(F) am tO $I OREGON d' 99ff �`'A Ut P,-.4 EXPIRES: 12/31/2016 August 7,2015 / 1 10 A WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE*61-7473 rev.02/16/2015 BEFORE USE. rr Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component. . Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the - miTek' erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding fabrication,quality control,storage,delivery.erection and bracing,consult ANSI/TPI1 Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Safely Information available from Truss Plate Institute,781 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Cilnw Heights,CA AS4110 Job Truss Truss Type Qty Ply POLYGON R45124649 PL15-264_UPPER F02 Floor 13 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Fri Aug 07 13:53:54 2015 Page 1 ID:DFkz9p3tCrPAGZnVberKOtyJvgB-XbOZzFYuCATEPMi39xj I1 QOZ6MZomLdfZNgfkdygBiR 1 0-10-12 1 1 1-2-0 1 1 0-10-8 1 1 2-6-0 1 Scale:1/2"=1' 1.5x3 II 3x4= 1.5x3 II 3x4= 1.5x3 II 3x4= 1.5x3 II 1 2 34x4= 4 5 6 • 7 8 pt... wipp,„„..--...iii - i L/ \ o N e a o e e n 1 13 12 11 10 9 3x4= 1.5x3 II 1.5x3 II 4x6= 3x6= 3x4= 1 1-1-12 11-8-12 12-312 I 1-1-12 0-7-0 0-7-0 13-8-41 I -4-8 Plate Offsets(X Yl— 12'0-1-8 Edge] [3:0-1-8 Edge] LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) f/defl L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.55 Vert(LL) -0.11 11-12 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.66 Vert(TL) -0.19 10-11 >847 360 BCLL 0.0 Rep Stress Incr YES WB 0.50 Horz(TL) 0.03 9 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight:62 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 14=596/0-4-4,9=596/Mechanical FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=819/0,3-4=1502/0,45=1502/0,5-6=-1871/0,6-7=1871/0 BOT CHORD 13-14=0/819,12-13=0/819,11-12=0/819,10-11=0/1932,9-10=0/1219 WEBS 2-13=0/369,3-12=-382/0,2-14=-1170/0,7-9=-1316/0,7-10=0/704,5-11=-471/0,4-11=-345/0,3-11=0/993 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Refer to girder(s)for truss to truss connections. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. �- PRop CaN <c, •„.. E�9 '0-2 CX 8`782PE �- 7 OREGON 0-'t'' EXPIRES: 12/31/2016 August 7,2015 t _ I AisWARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE 1611-7473 rev.02/16/2015 BEFORE USE. Design valid for use only with MBek connectors.This design is based only upon parameters shown,and is for an individual budding component. . Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding MiTek" fabrication,quality control.storage,delivery,erection and bracing,consult ANSI/TPI1 Qualify Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Safety information available from Truss Plate Institute,781 N.Lee Street.Suite 312,Alexandria,VA 22314. Suite 109 runs Heights,CA 0411n Job Truss Truss Type Qty Ply POLYGON 845124850 PL15-284_UPPER F03 Floor 2 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Fri Aug 07 13:53:55 2015 Page 1 ID:DFkz9p3tCrPAGZnVberKOtyJvgB-?nyxAbZWyUc51WHG'rfEXZdwpLm?ZugaoolaDG3ygBiQ z s o I 11..4...1111 I 1-2-0 1 1 0-8-14 1 Scale=1:22.8 1.5x3 II 1.5x3 II 3x4= 3x4= 1.5x3 II 354= 1.5x3 II 3 4 5 304= 6 7 8 —\i1 2 11< ' 1.1111.111.111111.11.1.1.11.111.1.11.1111— – 4110 s o 14 13 12 11 10 3x4= 3x6=1.5x3 II 1.5x3 II 3x6= 3x4= 6-5-2 17-0-2 I 13-1-8 I 5-10-2 5-10-2 0-7-0 0-7-0 B-1-6 Plate Offsets QC Y1-- 14'0-1-8.Edael.[5:0-1-8.Fdae] LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) 1/deft Lid PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.20 Vert(LL) -0.08 11 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.31 Vert(TL) -0.13 9-10 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.33 Horz(TL) 0.02 9 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:60 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 14=572/Mechanical,9=572/0-4-4 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=1740/0,3-4=-1740/0,4-5=-1761/0,5-6=-1739/0,6-7=-1739/0 BOT CHORD 13-14=0/1163,12-13=0/1761,11-12=0/1761,10-11=0/1761,9-10=0/1163 WEBS 2-14=-1256/0,2-13=0/622,4-13=268/180,7-9=-1256/0,7-10=0/622 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Refer to girder(s)for truss to truss connections. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. skti) PR ore. `g�� e_t EF,Q `S'/p 2 cr 89782PE 9` 0,/,4c,: ,,. -9,,�,OREGON ©>, / , 2 gRYj k, h'kPAUL0 EXPIRES: 12/31/2016 August 7,2015 4I I A WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MU-7473 rev.02/16/2015 BEFORE USE, Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction=the responsibillity of the MiTek` erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding [X! 1� fabrication,quality control,storage,delivery,erection and bracing,consul ANSI/TPII Qua01y Criteria,DS11-89 and SCSI Building Component 7777 Greenback Lane Safety information available from Truss Plate Institute,781 N.Lee Street,Suite 312 Alexandria,VA 22314. sut c Clinic CA scull Floor (Job Truss (Truss Type 2 1 Qty Ply POLYGON PL15-284 UPPER F04 R45124651 Pacific Lumber&Truss Co., Beaverton,Oregon Job Reference(optional) 7.530 s Jul 11 2014 MiTek Industries,Inc.Fri Aug 0713:53:56 2015 Page 1 ID:DF1d9p3tCrPAGZnVberKOlyJvgB-U_WJOxnjokyffsSGMIm6rT v9ITEGtylhJmpVygBiP 2-6-0 I I 1-8-6 I I 1-7-0 110-8-14 Scale=1:25.0 1.5x3 I I 3x4= 1.5x3 I I 3x4= 1.5x3 II 3x4= 3x4= 1 2 g 1.5x3 I I 4 5 6 7 8 u • 000001001.111111.11.111111111.°111.1.1.11111111.111k _ tr _ 1 13 12 11 10 3x4= 3x6= 1.5x3 11 1.5x3 11 3x6= 3x4= I 7-0-14 17-7-14 18-2-14 7-0-14 0-7-0 0-7-0 6-1-6 I Plate Offsets(X.Y)— [4:0-1-8.Edgej,[5'0-1-8.Edge] LOADING(psf) SPACING- 1-7-3 CSI. DEFL- in (loc) I/defl Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.21 Vert(LL) -0.11 12 >999 480 TCDL 10.0 Lumber Increase 1.00 BC 0.39MT20 220/195 360 BCLL 0.0 Rep Stress Incr YES Horz(TL)r -0.17 12 >999/a n/a WB 0.39 0.03 9 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight:65 lb FT=0%F,0%E LUMBER- TOP CHORD 2x4 DF No.1&Btr(flat) BRACING- BOT CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except WEBS 2x4 DF Stud/Std(flat) end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 14=626/0-2-8,9=626/0-4-4 FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=-2010/0,3-4=-2010/0,4-5=-2110/0,5-6=1999/0,6-7=1999/0 BOT CHORD 13-14=0/1294,12-13=0/2110,11-12=0/2110,10-11=0/2110,9-10=0/1295 WEBS 2-14=1397/0,2-13=0/773,4-13=317/104,7-9=-1398/0,7-10=0/760,5-10=-371/105 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Provide mechanical connection(by others)of truss to bearing plate at joint(s)14. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. ,c pcj PRQF C �NC"IN�� ` .Q ��O - .9782PE 9' OREGON N, -99gRY1`� t�� PAUL EXPIRES: 12/31/2016 4 August 7,2015 A WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE 861-7473 rev-02/16/2015 BEFORE USE, Design valid for use only with MiTek connectors.This design is based onlyupon Applicability of design parameters and parameters shown,and b sig a-not truss buildingi .Bracing shown is for lateral supportpropermincorporation Additional rary component 12 responsibilitying toinsure of building designer construction r-trot tiodesigner.Bra bng soown erector.Addial permanent brae g of the oove all structure istthe respons bility of the build ng designer.F or g neral guidancethe s regarding of the fabrication,quality control storage,delivery,erection and bracing,consult ANSI/TPI1 Quality Criteria,DSB-89 and SCSI Building Component ���®�^ - - Safety Information available from Truss Plate Institute,781 N.Lee Street,Suite 312 Alexandria,VA 22314. 7777 Greenback Lane Suite 109 runic Negmc CA OSntd Job Truss Truss Type IQty Ply POLYGON R45124852 PL15-264_UPPER F05 Floor 4 1 Job Reference(optional) 7.530 s Jul 11 2014 MiTek Industries,Inc.Fri Aug 07 13:53:56 2015 Paget Pacific Lumber6Truss co., Beaverton,Oregon ID:DFkz9p3tCrPAGZnVberKOtyJvgB-U WJOxZ8jokyffsSGMIm6rT 19JyEJXy1hJmpVygBiP I 2-0-10 1 1 1-2-0 1 1 0-8-14 1 1 2-E-0 I Scale=1:18.0 1.5x3 II 3x4= 1.5x3 II 3x4= 1.5x3 II 3 3x4= 1 2 4 5 8 4 x — N e e e/ 1 10- 1 8 1.5x3 II 1.5x3 II 3x6= 3x4— 3x4= 1 2-3-10 l 2-10-10 3-5-10 9-7-0 I 2-3-10 11-7-0 I 0-7-n 1 0-1-6 Plate Offsets(X.Y)— 12:0.1-8.Fdael 13:0-1-8.Fdael LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) 1/deft Ud PLATES GRIP >999 480 40.0 TCLL 40.0 Plates Increase 1.00 TC 025 Vert(LL) -0.05 BC 0.36 Vert(TL) -0 08 7-8 >999 360 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BCLL 0.0 Rep Stress Incr YES WB 0.22 Horz(TL) 0.01 7 n/a n/a Weight:44 lb FT=0%F,0%E BCDL 5.0 Code IBC2012/TP12007 (Matrix) LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD 2x4 DF No.1&Btr(flat) BOT CHORD Rigid rtiadirectly applied or 10-0-0 oc bracing. WEBS 2x4 DF Stud/Std(flat) REACTIONS. (lb/size) 11=416/0-2-12,7=416/0-4-4 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 2-3=-767/0,3-4=-989/0,4-5=-989/0 BOT CHORD 10-11=0/767,9-10=0/767,8-9=0/767,7-8=0/782 WEBS 2-11=-851/0,5-7=-844/0,3-8=0/406 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Provide mechanical connection(by others)of truss to bearing plate at joint(s)11. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-1Od(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. � c50PROi 1:C. 4 GINE �' ��%q zr 89782PE f .11 it ir iii ON-$ •REG ©) Q" Id4RYi *J . AUL ` EXPIRES: 12/31/2016 August 7,2015 1 , aWARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERANCE PAGE/111.7473 rev,02/16/2015 BEFORE USE. Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component. �Y Applicability of design parameters and proper incorporation of component b responsibility of building designer-not truss designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the erector.Additional permanent bracing of the overall structure is the responsibfity of the building designer.For general guidance regarding 7777 Greenback Lane fabrication.quality control,storage,delivery,erection and bracing,consult ANSI/TPI1 Quality Criteria,DSI-89 and SCSI Building Component 7 Safety Information available from Truss Plate Institute,781 N.Lee Street,Suite 312,Alexandria,VA 22314. 767 109 suite Heights CIA cisme Job Truss Truss Type Qty Ply POLYGON PL15-264 UPPER F06 R45124653 Floor 11 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Fri Aug07 13:53:57 2015 Pa e 1 I D:DFkz9p3tCrPAGZnV berKOtyJvg6-yA4hbHam USspGpReg3G?e203vNzhM5FL3JLyygBiO I 2169 I 2-1-12 1 1 1-2-0 11 0-9-8 1 2-3-0 I 1 1-2-0 1 1 1-4-0 1 1-6-0 1 Scale=1:27.8 1.5x3 I I 3x5= 1.5x3 II 1.5x3 II 3x4= 1.5x3 II 3x4= 1.5x3 II 3x8= 1.5x3 II 1 2 3 4 5 6 7 8 9 10 mail .: Ale liiiillIIIIIIIIIIIIIIIiuwpek Web: e ' e ti e 1 16 15 14 13 12 11 3x4= 3x4= 3x4= 3x6= 1.5x3 I I 3x5= 3x4 = 4-10-12 12-10.12 55-12 12 4-10-12 10.7-0 0-7-0 1 11-8-12 ,2-3-0 1 I 15-11-12 I 5-8-0 o-7 a 0-7-0 3-1-0 Plate Offsets(X l_)— U:0-1-8 E.g.01 12.0-1-8.Edge],(15:0-1-8,Edge].[16'0-1-8 Edge] LOADING(psi) SPACING- 1-7-3 CSI. DEFL. in (lac) 1/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.64 Vert(LL) -0.23 13-14 >812 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.78 Vert(TL) -0.36 14-15 >522 360 BCLL 0.0 Rep Stress Incr YES WB 0.57 Horz(TL) 0.04 11 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight:72 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 17=697/0-4-4,11=697/Mechanical FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=-2351/0,3-4=-2351/0,4-5=-2351/0,5-6=-2679/0,6-7=-2679/0,7-8=1863/0,8-9=-1863/0 BOT CHORD 16-17=0/1468,15-16=0/2351,14-15=0/2590,13-14=0/1863,12-13=0/1863,11-12=0/965 WEBS 3-16=304/0,4-15=0/264,8-12=448/0,2-17=-1585/0,2-16=0/983,7-14=0/950,6-14=-281/0,5-15=-490/0, 9-11=-1159/0,9-12=0/1121 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Refer to girder(s)for truss to truss connections. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 'S , 1aD PRO FGINE ss 6,9 2 89782PE 91• gar to 9,�OREGON '.• 4' PAUL Ck‘m EXPIRES: 12/31/2016 August 7,2015 f I A WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev,02/16/2015 BEFORE USE. r. Desi n valid for or useeonly with e7ek connectors.i Thiscporati in based only upon parameters shown,and is for individual buildingicomponent. • Applicability of design parameters and proper incorporation of component k responsibility of building designer-not truss designer.Bracing shown is for lateral support of individual web.members only.-Additional temporary bracing to insure stability during construction is the responsibillity of the `� erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding MII AT ek• fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/TPI1 Qualify Crtieda,DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute,781 N.Lee Street,Suite 312,Alexandria,VA 22314. 7777 Greenback Lane Suite 109 rade%Heights rA 55Rtn • Job Truss Truss Type Qty Ply POLYGON 845124854 PL15-264_UPPER F07 Floor 11 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon7.530 s Jul 11 2014 MITAIndustries,Inc.Fri Aug 07 13:53:58 2015 Page 1 ID:DFIcz9p3tCrPAGZnVberKOtyJvg6-QMe3pdbPFP_guz0g0nnEBGYKrc?RiDBEU?ottOyciBiN 1 1-9-14 I I 1-2-0 1 1 0-8-14 I I 2-6-0 I Scale=1:17.6 1.5x3 II 3x4 = 1.5x3 II 3x4= 1.5x3 11 412 3 3x4= 4 5 6 • • e- _,,ti • e — 0 N — — r e A 11 10 9 8 1.5x3 I I 1.5x3 11 3x6= 3x4= 3x4= 2-0-14 12-7-14 I 3-2-14 I 34-4 I 1 2-0-14 0-7-0 n-7-ti 6-1-6 Plate Offsets(X Yl— 12:0-1-8 Fdael.13:0-1-8.Fdael LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) 1/deft L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.24 Vert(LL) -0.04 8-9 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.36 Vert(TL) -0.08 7-8 >999 360 BCLL 0.0 Rep Stress Incr YES WB 022 Horz(TL) 0.01 7 n/a n/a Weight:43 lb FT=0%F,0%E BCDL 5.0 Code IBC2012/TP12007 (Matrix) LUMBER- BRACING- TOP CHORD 2x4 DF No.t&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 11=406/Mechanical,7=406/0-4-4 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=-702/0,3-4=-940/0,4-5=-940/0 BOT CHORD 10-11=0/702,9-10=0/702,8-9=0/702,7-8=0/757 WEBS 2-11=796/0,5-7=-817/0,3-8=0/420 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Refer to girder(s)for truss to truss connections. 3)Recommend 2x6 strongbackS,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. ��s\V PR Opt C 89782PE c'" ..i/ y •REGON a', 4" 49 �4RY A,o 2�t<,t2 k PAUL R� EXPIRES: 12/31/2016 August 7,2015 1 1 ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE 610-7473 rev.02/16/2015 BEFORE USE. Design valid for use only with MTek connectors.This design is based only upon parameters shown,and is for an individual building component. . Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the �T9kt erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding Greenback Lane fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/TPI1 Quality Criteria,DSB-89 and B7777 CSI Building Component Suite 109 Safety Information available from Truss Plate Institute,781 N.Lee Street,Suite 312,Alexandria.VA 22314. Cunt N9roms r.4 A5A1n Job Truss Truss Type Qty Ply POLYGON R45124655 PL15-264_UPPER F08 Floor 2 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Fri Aug7 13:53:59 2015 Page 1 I D:DFkz9p3tCrPAGZnVberKOtyJvgB-uZBSOzc10j6X W 7b1 xUJTk<TSMGNFRRbbOjfYQPgygB iM 1 2-6-0 1 2-1-12 1 1 1-2-0 1 1 0-9-8 1 2-3-0 1 I 2-3-0 1 1 1-2-0 110-6-8 I Scale=1:28.5 1.5x3 II 3x5= 1.5x3 II 1.5x3 I I 3x4= 1.5x3 II 3x4= 1.5x3 II 4x4= 1.5x3 II 1 2 3 4 5 6 7 8 9 10 C N 11 Af 44141111441441114,44: e e ° °e 1 16 15 14 13 12 ...n. 3x4= 3x4= 3x4= 3x6= 1.5x3 I I 4x4= 3x4 =- 12-10-12 12-10-12 I 4-10-12 5-05-12�p.12 1 4-10-12 0-7-0 0-7-0 1 11-8-12 5-8-0 12-3-12 0-7-0 10-7-0 I 164.4 3-5-8 Plate Offsets(X Y)— [7:0-1-8.Edge] 112-0-1-8 Edge].115.0-1-8 Edge] 116:0-1-8 Edge] LOADING(psi) SPACING- 1-7-3 CSI. DEFL- in (loc) I/deft L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.71 Vert(LL) -0.25 14-15 >783 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.76 Vert(TL) -0.39 14-15 >501 360 BCLL 0.0 Rep Stress Incr YES WB 0.52 Horz(TL) 0.05 11 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:73 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 17=714/0-4-4,11=714/0-4-8 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=-2435/0,3-4=-2435/0,4-5=-2435/0,5-6=-2821/0,6-7=-2821/0,7-8=-2063/0,8-9=-2063/0 BOT CHORD 16-17=0/1509,15-16=0/2435,1415=0/2698,13-14=0/2063,12-13=0/2063,11-12=0/1552 WEBS 3-16=-319/0,4-15=0/287,8-12=-559/0,2-17=-1629/0,2-16=0/1028,7-14=0/894,6-14=-276/0,5-15=-526/0, 9-11=-1675/0,9-12=0/946 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. A, 4'£DPR©FSGINE � 44 2 ` ' 89782PE r . ill -5, •REGON 1N 4. 9� �.4R1' 16 !` EXPIRES: 12/31/2016 August 7,2015 t I WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE M/1-7477 rev.01/16/2015 BEFORE USE, N • Design valid for use only with MTek connectors.This design is based only upon parameters shown,and is for an individual building component. Applicability of design parameters and proper incorporation of component B responsibility of building designer-not truss designer.Bracing shown Is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the ■ erector.Additional-permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding -M I]Tek -- - fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/T911 Qualify Cdteda,DSB-89 and BCSI Building Component 7777 Greenback Lane Safely Information available from Truss Plate Institute,781 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 C.4n,c Heights CA 145810 Job Truss Truss Type Qty Ply POLYGON R45124656 PL15-264_UPPER F09 Floor 4 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Fri Aug 07 13:54:00 2015 Page 1 ID:DFkz9p3tCrpAGZnVberKOtyJvgB-MllgEJccfnn0E07HADVCgiGheXZnbxA2zXyJHyHygBiL I 2-6-0 I 2-1-12 1 1 1-2-0 1 1 0-9-8 1 2-3-0 I I 2-3-0 1 1 1-2-0 I 9-6-171 Scale=1:28.2 4x4= ,- 1.5x3 II 3x5= 1.5x3 II 1.5x3 II 3x4= 1.5x3 I I 3x4= 1.5x3 II 1.5x3 II 1 2 3 4 5 6 7 8 9 10 e _ _ a\ e e/_ _ f . °/�\ / e N a' 6° p ....41. e e 44xA 1NI 16 15 14 13 12 3x4 = 3x4= 3x4= 3x6= 1.5x3 II 4x4= 3x4= 12-10-12 4-10-1215-5-12 0-12 11-8-12 12-3-121 I 16-2-8 I I 4-10-12 0-7-0 0-7-0 i 5-8-0 0-7-0 0-7-0 3-3-12 Plate Offsets(X.Y)— p'0-1-8.Edge].[12:0-1-8.Edgf:].[15'0-1-8.Edge].[16:0-1-8 Edge] LOADING(psi) SPACING- 1-7-3 CSI. DEFL- in (loc) 1/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.74 Vert(LL) -0.24 14-15 >797 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.74 Vert(TL) -0.38 14-15 >510 360 BCLL 0.0 Rep Stress Ina" YES WB 0.51 Horz(TL) 0.04 11 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:73 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 17=707/0-4-4,11=707/0-2-12 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=2402/0,3-4=-2402/0,4-5=-2402/0,5-54-2764/0,6-7=-2764/0,7-8=1993/0,8-9=1993/0 BOT CHORD 16-17=0/1493,15-16=0/2402,14-15=0/2656,13-14=0/1993,12-13=0/1993,11-12=0/1545 WEBS 3-16=-314/0,4-15=0/278,8-12=-636/0,2-17=161210,2-16=0/1011,7-14=0/903,6-14=-276/0,5-15=-512/0, 9-11=-1668/0,9-12=0/975 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Provide mechanical connection(by others)of truss to bearing plate at joint(s)11. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4,fckEp PROpt NG1NEccR 02 t8.782PE _<` / ;e `Y,L OREGON fir., 14) 9 L^7Ry 1 PAUL ' EXPIRES: 12/31/2016 August 7,2015 ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MI47473 rev.02/16/2015 BEFORE USE. Design valid for use only with Wel(connectors.This design is based only upon parameters shown,and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the /L A'Tel." erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding INI E R fabrication,quality control.storage,delivery,erection and bracing,consult ANSI/TPI7 Quality Criteria,DSB-89 and SCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,781 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Canis Hoights,CA 64610 Symbols Numbering System Q General Safety Notes PLATE LOCATION AND ORIENTATION 1 3j" Center plate on joint unless x,y I I 6-4-8 dimensions shown in ft-in-sixteenths Failure to Follow Could Cause Property offsets are indicated. (Drawings not to scale) Damage or Personal Injury MEI Dimensions are in ft-in-sixteenths. hik Apply plates to both sides of truss and fully embed teeth. 1 2 3 1. Additional stability bracing for truss system,e.g. TOP CHORDS diagonal orX-bracing,is always required. See BCSI. 0-�/j 6 2. Truss bracing must be designed by an engineer.For wide truss spacing,individual lateral braces themselves 4 may require bracing,or alternative Tor I _ p bracing should be considered. r (=j O 3. Never exceed the design loading shown and never 2 a0 U stack materials on inadequately braced trusses. — cy� cs 4. Provide copies of this truss design to the building For 4 x 2 orientation,locate C7` designer,erection supervisor,property BOTTOM CHORDS other P P p rty owner and plates 0 ' a from outside all interested parties. edge of truss. 8 7 6 5 5. Cut members to bear tightly against each other. This symbol indicates the JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE 6. joint and embed fully.Knots and wane at joint required direction of slots in AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO locations are regulated by ANSI/TPI 1. connector plates. THE LEFT. 7. Design assumes trusses will be suitably protected from `Plate location details available In MiTek 20/20 CHORDS AND WEBS ARE IDENTIFIED BY END JOINT the environment in accord with ANSI/TPI 1. software or upon request. NUMBERS/LETTERS. 8. Unless otherwise noted,moisture content of lumber shall not exceed 19%at time of fabrication. PLATE SIZE PRODUCT CODE APPROVALS 9. Unless expressly noted,this design is not applicable for ICC-ES Reports: use with fire retardant,preservative treated,or green lumber. The first dimension is the plate 10.Camber is a non-structural consideration and is the 4 x 4 width measured perpendicular ESR-1311,ESR-1352,ESR 1988 responsibility of truss fabricator.General practice is to to slots.Second dimension is ER-3907,ESR-2362,ESR-1397,ESR-3282 camber for dead load deflection. the length parallel to slots. 11.Plate type,size,orientation and location dimensions indicated are minimum plating requirements. LATERAL BRACING LOCATION 12.Lumber used shall be of the species and size,and in all respects,equal to or better than that i� OIndicated by symbol shown and/or specified. by text in the bracing section of the output. Use T or I bracing 13.Top chords must be sheathed or purlins provided at spacing indicated on design. if indicated. 14.Bottom chords require lateral bracing at 10 ft.spacing, BEARING or less,if no ceiling is installed,unless otherwise noted. vs..- 15.Connections not shown are the responsibility of others. Indicates location where bearings 16.Do not cutor alter member or plate without prior vll supports) occursection.indicates Icons varyjbointut ©2012 MiTek®All Rights Reserved approvall of an engineer. reaction( ® ( number where bearings occur. MI • 17.Install and load vertically unless indicated otherwise. Min size shown is for crushing only. 18.Use of green or treated lumber may pose unacceptable environmental,health or performance risks.Consult with Industry Standards: project engineer before use. ANSI/TPI1: National Design Specification for Metal 19.Review all portions of this design(frontback,words Plate Connected Wood Truss Construction. and pictures)before use.Reviewing pictures alone � DSB-89: Design Standard for Bracing. is not sufficient. BCSI: Building Component Safety Information, eIC 20.Design assumes manufacture In accordance with Guide to Good Practice for Handling, MiTANSI/TPI 1 Quality Criteria. Installing&Bracing of Metal Plate Connected Wood Trusses. MiTek Engineering Reference Sheet:MII-7473 rev.02/16/2015