Loading...
Plans (54) A B 66'-10- . Markup Legend SPRINKLER SYMBOL DEFINITION ex 19-' „-°- cs 16-° "-,- i t COLOR/LINETYPE LEGEND ,� BLUE LINES=FEED TO FIXTURES(BATH,SHOWER,ETC.). o Delete Line ^\`\/ 0 XXX XX n — i 1 1 i - 1 iI GREEN LINES= INTERLEVEL CONNECTIONS/SUPPLY. J u I f ,, 0 ii0 BLACK LINES=SPRINKLER HEAD TO SPRINKLER HEAD. O o MAXIMUM SPACING(TYP) I I I� r, r —h— = 1/2"PIPE SIZE >'''..4. o Add Line SPRINKLER HEAD SYMBOL(TYP) �- �' i:jj �,I��j��% i, Q ' ' �,;— =3/4"PIPE SIZE a ,@), Add Tee ▪ .▪ �, b3!. 7�1 /;il ID �� { L'Il BCS gip, o ,> .15' 56 L = 1"PIPE SIZE 0 N; Li v./ ,, r4/ / ,' �l. � = 1-1/4"PIPE SIZE w s LL w o Add Elbow �I �,V/d?3IA /!i 0 I j w m z O Add Coupling CITY OF TIGARD in 11; ./ 'j� 11 IIS = kiQ`o3 �, „ U,5 I— Add Head 1 3- Approved I on �x� _ u,, ri ,� - i/fin J e RECEIVED Conditionally Approved [ ] _� Delete Head �' I , �j I� z ..,,,,-.g ,� See Letter to: Follow [ ] /. ILII Ny � *1 5 Move Head iO- -...\O- Attached j — jA i ,./ :i I. MAR 1. 5 2017 <.'.F0000 ,-U Permit Number:f+St?.o►6-D o 4t . e_;'II 99CC a "`Q �.� I: , t �� ozoc:c., oca Note:All revisions must be reviewed by Uponor �' t '� 61�z CITY OF TIGARD - z a Address: »0S S W IQdCK y /l�!►inot atir --- �_ ;e _n�— Table P002-1 c<cx -uzo35" 6 BUILDING DIVISION �000�d���w�z Multipurpose Fire Safety Systems B 0 z .,.J'_N-u= . o ,tF4(a Date: 3. ?, �? d 700o�.o`x The U onor Residential Fire Safe System d a residential fire protections -' 5 R (G 'K Y P e z y z w c o - system installed in combination Safety the cold side of the domestic potable • . ,�,y,. .� `, U LDV 5 KEN(E 1 1 LAN w>'�e 3 5 E,e c z 3 t'� W mpmv,>v z� water system. Only licensed contractors trained by Uponor can install this r--- 1- --- -- ,o_�<y a>e_ system. F100 • I'"saoa°.,z"iac j w_L,L2�oze�,.E. What to do if Changes are Required NTS U a�C <u'='..c 3 �y If any features or obstructions require the addition or deletion of spookier 1"AQUAPEX INTERLEVEL 1"AQUAPEX INTERLEVEL ,�.,LL CE.f z e E z>,r a E,� heads,or significant relocation of sprinkler heads,contact the U onor Design Q Q m 3 d E--<. .;;;,,c,,, 9 P P 9 CONNECTIONS FROM SECOND CONNECTIONS FROM FIRST �- < z c Department to t6)determine if observed changes require a redesign FLOOR TO THIRD FLOOR — FLOOR TO SECOND FLOOR �, .'',.E z o 0 3 c,i*z¢ Y o MOST HYDRAULICALLY REMOTE HEADS ET ,, #I \\ly ,--- / A R �� Q°� �` 7>°5,<o< �,i . .J,..\t� ...... _III_ = Oz¢oW ,t< HEAD# GPM PRESSURE RE DAT STREET i I 2 HEAD H.7&H.6 26.0686 58.4 N 6L 1 HEAD H.1 17 39.53 —_ �I7 L -,gym = � 2° a � s \ N , ,, uc zl-oz< I N ii,� I \ '\ \ Y z c ow m x- c <oz- / I N / I v 1 1st Floor .LI.-'�,i �I II� -I �� - 1 2nd Floor / I 7 2n Floor \ _ RC RC) & I AR�. / I �` j s.,.MAIN SHUTOFF OFFICE T! T01� ■/�� 12 TOTAL 1, Y �� �., '.�. RC-R S-16 t, -. 11 �I .,* =_ VALVE LOCATION V.l'1'ICL C V PY I SENJU Model RC-RES Residential Flat Concealed Pendent SS8464 �� / --,l r1 � I A 'Tandem 2-Car 0 - - - 1Spacing --ii-21.18 I� T.1 I g .< K=4.9, 162F°,7/16"Orifice,Maximum S acin 18'x18' 1r RC-RES-18 Sprinkler head demand: 17 gpm @ 12N C,al 8 SENJU Model RC-RES Residential Flat Concealed Pendent SS8464 T a \ ,6T�a 0 - - - 10 K=4.9, 162F°,7/16"Orifice, Maximum Spacing 16'x16' �� 1__ 1� e Sprinkler head demand: 13gpm©7.04 �, t �� T.20 s RC-RES-16 ' .. - ' o \ P t f 1 '- 1"Aqua PEX TO SYSTEM SENJU Model RC-RES175 Residential Flat Concealed Pendent SS8464 hh, ,) 1 M.22 7v1eC}t 0 - 1 K=4.9, 175F°,7/16"Orifice,Maximum Spacing 14'x14' iii I ,t ..ch'",- ii, / T: 1 1� r_ „t•T•��5 �� RC-RES-14-175 Sprinklergpm11,e6F.3 F 2/ AT head demand: 13 ©7.04 1 - F /I a I Y II'' H.3 / H.2 _' A'23- r I ItiL r E 2\ . I U"� f z `" L®d C i 1j -III - 11� V-IF R '; r r 1 .. a E�16� ,,-,, '1'15-'IR _ Q ''''-'61."':-.26,- 16 -1 r 4 / A r� L ..I, r,�I z���JJJ .F m tii r n Ll l ,, I 1 Y \ -^ -.-. I - K In .. s: � CZ � �, R Reis�I�� T T.29� LT 33 T� . 1''A[,_ a w K f — _ 1,� 'S _ r 1 y _ z 0 W O ELEV-109' T,28 WATER PRESSURE E' CURRENT STATIC EXTERIOR WALL T �i 29 I " ( ,tax `T -,,1 t2 N o 0 0 °C v w { t; ,,, .TI < o�> STATIC: 62psi / \ —_ 0� fV ^ o R Rs16 w o t, 1"AquaPEX Il (H f 7 --+---r 1� �c c ul / \TO SYSTEM 2 RE � tic CRE J 1� 1 .I _ I (n OC m TO HOT WATER HEATER 1 Ii Er 3 ���Iso r �� 3 g S1 \ - n.l r I. I - _ `/ , ri F''': ELEV=104' i -- % , I' " HE E F ,/ -a - __ __ __� Z °' // BALL VALVOE T I 1 L. {� 1 I J m a m m-r o > Ir. �� � - �, G ..-y-moi � , I _iI I ..,,: m � G3ussa a mcitw ELEV=100' ELEV=100'IIID / % .-- =P F LL� 3 THIRD FLOOR 2 SECOND FLOOR FIRST FLOOR 6�UVya =� // 7////////1 SHEET DESCRIPTION - 35'OF 1"METER 100'OF F1OO, II — n ALL LEVELS F100 _ I �� 1"COPPER-K 1-1/2"AquaPEX hi" 1�4 1:-0" 1�4 = 11-�n F100 1�4n _� SHEET NUMBER �4 WATER SERVICE DETAIL 5 15 F100 1/4"=1:_D: F100 NTS © UPONOR - CONFIDENTIAL Markup Legend SPRINKLER SYMBOL DEFINITION %e, -e sa•-�� COLOR/LINETYPE LEGEND is-r s'-, t '° ' i s'- •r BLUE LINES= FEED TO FIXTURES(BATH,SHOWER,ETC.). a Delete Line XXX-XX r GREEN LINES= INTERLEVEL CONNECTIONS/SUPPLY. J } r t,'I BLACK LINES=SPRINKLER HEAD TO SPRINKLER HEAD. O MAXIMUM SPACING(TSP) I, 4 = 1/2"PIPE SIZE a~° Add Line SPRINKLER MODEL(TYP) i , HEAD SYMBOL(TYP) •.—. --• ' a�/ ' f ' —e— =3/4"PIPE SIZE a:'-',@•° Add Tee ( 4- i��/// / i �j ,i =i - = 1"PIPE SIZE 0 1-•;;`,;(,)?ry u 22 4i Ai ��, 0 I m>z 1 L 6 ii GC 6%®i'� r K-6G /ii ''1t 1I:Lr - = 1 1/4 PIPE SIZE u v LL,o0 Add Elbow �i �� � Ii I >,vim.,ry �� � , � / / ii wiii� Y� Add Coupling I �- mjirr" / i'®/' / i��� ..'^ 3 Add Head -A 1\ el e h I' ligro% I Ii I Ailli, .g.;,.... ��i --a. Iti / // p,�i®�F_, 7//Xiii B < o� JDelete Head -lXl- r,, Il ���' --; i�l � �i " � v> F���u���� frpAg mix/z;e rt ill Move Head -0-• -O- iµµL.D iAy,41iii z'Al MJ wH ¢Nwoc>Q Note:All revisions must be reviewed by Uponor it,' ii Ai0Ij �,� <o m y a a Table F002-1 'i 1 ,q.(�- � .^ Z - A Senju RC-RES:Open Web Truss/TJI Construction Insulation Recommendations TM See General Notes 8.2.5.7 for Architectural AquaSAFETM GENERAL NOTES: In areas subjectto freezing,care should be taken in unheated attic spaces ProPEX LF Brass Fire to cover Uponor AquaPEX tubing completely with insulation. Insulation Feature Requirements q \ should followtthe guidelines of the tic numanufacturer.in See Uponor z SECTION 3.3.11.3. Sprinkler rIf Adapter ` - i Pus Sprinkler Adapter Document"Uponor AquaSAFE Attic Insulation Guidli s package for attic ` O o P 1. THIS SYSTEM IS DESIGNED AS PER NFPA 13D 2016 EDITION AS A RESIDENTIAL MULTIPURPOSE SYSTEM Fire BlockingMaybe _ _ Required.If - h-on Nut installation guidelines(Provided in Contractors Documents or online 'w u at www.0 onor ro.com. o 2. UPONOR COMPANY RESERVES THE EXCLUSIVE RIGHTS TO ALL DETAILS AND DRAWINGS AS SHOWN ON Blocking is Used, 11/q"Mni . p p ) I 1 a..z Use The 2 Top • t w^a THIS SHEET. THESE DETAILS AND DRAWINGS ARE PROPRIETARY INFORMATION OF UPONOR COMPANY AND 1/"Max. UNAUTHORIZED USE MAY BE SUBJECT TO PROSECUTION TO THE FULL EXTENT OF THE LAW. Screw Holes. :9 /�, Bottom of Mounting Extreme Temperature Installations Planter Box Window,Bay Window or Similar Feature. o Bracket to Face of Truss AquaSAFE Residential Fire Safety systems are often installed in attics or If no additinal floor area is created No Additional Sprinkler is Required. a;3.; 10 u a 3. THE DESIGN OF THIS SYSTEM IS DICTATED BY SPECIFIC CEILING HEIGHTS AND ROOM SIZES. IT IS THE -. other areasexposed to xtr mes of heat and/or cold. Follow m Fire Sprinkler Adadter - the a pose e e d/o i 8'-0"or less N bl RESPONSIBILITY OF THE INSTALLING CONTRACTOR TO ENSURE THAT THE CONDITIONS SHOWN ON THESE MountingBracket the recommended extreme weather installation instructions to isolate and / m 5 PLANS ARE EXACTLY AS THEY EXIST IN THE FIELD. DEVIATIONS FROM THE DESIGN MAY CAUSE THE ��J , protect system components from extreme temperatures. Because this RC-RES-161 w 3..,1,`O SYSTEM TO BE UNABLE TO CONTROL A FIRE.IF THE BUILDING CONSTRUCTION DIFFERS FROM THE FIRE ® a" u v u?oz SPRINKLER PLAN,CONTACT THE SYSTEM DESIGNER IMMEDIATELY. 3-#10 x 1 1/2" system also delivers domestic cold water directly to plumbing fixtures, z a 9'-0"or lessQ >;,`'°, _ -� Uponor highly recommends that you protect the tubing with adequate / z m Full Course I - at w t o � m 4. THIS SYSTEM AND THE ACCOMPANYING HYDRAULIC CALCULATIONS ARE DESIGNED IN COMPLIANCE WITH Thread Screws 1ll�rtr insulation in warm weather areas to minimize heating of the cold water NFPA 13D 2016 EDITION. In Bottom Holes supply. o - wa -w w 5. "STAND-ALONE"OR"MULTIPURPOSE,WET PIPE"SYSTEMS ARE NOT PERMITTED TO USE ANTI-FREEZE. \.. \ Installation methods include,but are not limited to: Fq o m w§',w S w • Tenting over the fire sprinkler piping. OF'w 3 Lead-Free.Flat -. -5 layers of batt insulation. If additional floor area is created.Cannot exceed 18 ftt,be more than 2'-0" 6. MODIFICATIONS ARE PROHIBITED.SPRINKLERS THAT HAVE BEEN PAINTED,CAULKED,MODIFIED OR - t, : Additional Concealed Sentu L Concealed Flat z DAMAGED MUST BE REPLACED. • Increased depth of blown-in insulation. deep,more than 9'-0"wide and be with in the coverage area of the < 2-'-'� '' Sprinkler Head Cover Plate sprinkler.No Additional Sprinkler is Required. z o u`z o y r u a 7. WATER SHUT OFF VALVE IS NOT PERMITTED THAT ISOLATES THE SPRINKLER SYSTEM. Caution: If you will be installing spray foam insulation,make sure to 2,%, r.1`a z 0 o o �=V=rr3 Senju RC-RES:Traditional Wood FramingConstruction Protect all components during application.Consult with the spray foam a`c o¢27 o 0 o w x°5 8. OWNERS MANUAL MUST BE PROVIDED TO THE OWNER. manufacturer to ensure compatibility with all products before application. NFPA 13D Table 7.5.5.3 Distances From -¢y y z 0 ,z<o z Heat Sources ",10aofw59yo 9. AT THE MAIN SHUT OFF VALVE,A TAG OR A SIGN STATING THE FOLLOWING IS REQUIRED;"WARNING,THE Consultation with local building officials is encouraged to ensure compliance ft o 2 o'1 z=2 z F m o WATER SYSTEM FOR THIS HOME SUPPLIES FIRE SPRINKLERS THAT REQUIRE CERTAIN FLOWS AND with local building codes. o m u=0 3<u PRESSURES TO FIGHT A FIRE.DEVICES THAT RESTRICT THE FLOW OR DECREASE THE PRESSURE OR ProPEX LF'Brass Fire OrdinaryIntermediate 6,`,.4 a x< Fire Sprinkler Adapter o o z�z�r y"6 AUTOMATICALLY SHUT OFF THE WATER TO THE FIRE SPRINKLER SYSTEM,SUCH AS WATER SOFTENERS, Sprinkler Adapter Tee Heat Source Temp. Temp. z z z�y o o z J t--r FILTRATION SYSTEMS AND AUTOMATIC SHUT OFF VALVES,SHALL NOT BE ADDED TO THIS SYSTEM , Push-on Nut 135°-170° 175°-225° z w<Y m"�" -z o WITHOUT REVIEW OF THE FIRE SPRINKLER SYSTEM BY A FIRE PROTECTION SPECIALIST.DO NOT REMOVE �~ BendingPEX Tubing <0 o ¢ °`�"`' THIS SIGN". I t Side of Fireplace 36" 12' d'o_ z o Q m o o` N z 1/q'Min. The minimum bend radius of Uponor PEX tubing in any direction is six times >.y <_5 Q,o F r, a L Front of Fireplace 60" 36" W m -r> z 3- __� �- 1/ Max, the outside diameter(6 x OD). ❑_< o 9 9¢z<9°: 10. ALL INTERIOR PIPING TO BE UPONOR"AquaPEX®"UNLESS NOTED. Bottom cf Mounting Wood Burning Stove 42" 12" N m<o<d i-z<F 9 z c Fire Sprinder Adapter - Bend supports are available for 3/8",1/2",3/4"and 1"Uponor AquaPEX Kitchen Ran 18" Q a a 7 o z z o o <,z z Bracket to'race of Truss 11. UPONOR"AquaPEX"TUBING TO BE SUPPORTED PER NFPA 13D AND MANUFACTURER'S RECOMMENDATIONS. Mounting Bracket tubing to facilitate 90-degree rigid bends. 9e _ J ,z<_o p�,z o \�J Wall Oven 18„ g„ (-11j 5. .;''''6I, r Q 12. MINIMUM SPACING BETWEEN SPRINKLERS IS 8'-0" REFER TO SPACING CHARTS FOR MAXIMUM SPACING 2-#10 x 1 1/2" O 0 Recommended Tubing Length Between Fittings Hot Air Flues 18" 9" N u<u z v z o v¢��,E. BETWEEN SPRINKLERS AND FROM WALLS.SPRINKLER HEAD MANUFACTURERS MAY HAVE MORE Full Course r Fittin Size Minimum Tubin Length Uninsulated Heat Ducts 18" 9" 0 m ,'a x o 6°5 W J RESTRICTIVE SPACING LIMITATIONS. Thread St rows I {.,-,� 1 T-t 9 9 9 a o c z o u c >o- In Top Holes 13 U 3/8"ProPEX Fitting 2" Uninsulated Hot Water Pipes 12" 6" <"x 9 o 9 z 9 r 2" x��oz F�.d o< zo 13. SPRINKLERS ARE NOT NECESSARILY CENTERED IN ROOMS DUE TO LIGHT FIXTURES OR OTHER CEILING Side of Hot Air Diffuser 24" 12" o<z a 3 7: o=o o: o u9u a9J o 1/2"ProPEX Fitting 21 zdv°.❑Fd N-ou<.�¢ MOUNTED OBSTRUCTIONS. 9 /2 - A- A Front of Hot Air Diffuser 36" 18" 3 o u�r< 3/4"ProPEX Fitting 3 1/2" Hot Water Heater 6" 3" 9 z z 90 o o 5 9 o m 14. THE PLUMBING TIE IN CONNECTIONS ARE SCHEMATIC IN NATURE AND CAN BE INSTALLED OFF THE Lead-Fre Flat - - - o c o m z o m o p❑o 02 SPRINKLER LOOP ANYWHERE BETWEEN SPRINKLER TO SPRINKLER CONNECTION. \. - r 1"ProPEX Fitting 41/2" Furnace 6° 3° F" o _>�><492 Conceale Sen1u Concealed Flat r o • < tw Sprinkler Head Cover Plate 1 1/4"ProPEX Fittin 5 1 2' 50W-250W Light Fixture 6" 3° ,3 •->o a u ig z z o<m-, 15. THIS SUGGESTED LAYOUT IS BASED UPON INFORMATION PROVIDED BY OTHERS. CHANGES IN 0 / 250W-499W Light Fixture 12" 6" 9 w 9 z=<o U-w-o z a a CONSTRUCTION OR FIELD CONDITIONS MAY OCCUR WHICH MAY REQUIRE CHANGES TO THE LAYOUT. IT IS u 3 r c�o- x2226999 22v,a THE RESPONSIBILITY OF THE INSTALLER TO NOTIFY UPONOR TECHNICAL SERVICES OF SUCH CHANGES. \ o w "i p z¢o <v0_10< Exposed Installation Requirements. a 16. NFPA 13D 8.2.5*OBSTRUCTIONS TO RESIDENTIAL SPRINKLERS \ I m • 8.2.5.6* SHADOW AREAS SHALL BE PERMITTED IN THE PROTECTION AREA OF A SPRINKLER AS LONG AS Uponor AquaPEX"'tubing(white)and Pro installation EP Fittings and ProPEX'ping THE CUMULATIVE DRY AREAS DO NOT EXCEED 15 FTc PER SPRINKLER. Brass Fittings are approved for exposed where the following • 8.2.5.7 SMALL AREAS CREATED BY ARCHITECTURAL FEATURES,SUCH AS PLANTER BOX WINDOWS,BAY conditions are met.(UL 1821 Approved) WINDOWS,AND SIMILAR FEATURES,SHALL BE EVALUATED AS FOLLOWS: = m // O (1)WHERE NO ADDITIONAL FLOOR AREA IS CREATED BY THE ARCHITECTURAL FEATURE,NO Exposed Wood Joist Ceiling Assemblies. // um ADDITIONAL SPRINKLER PROTECTION IS REQUIRED. 1. Joists are of dimensional lumber,engineered wood,wood I-joist or open "1 11 °m (2)WHERE ADDITIONAL FLOOR AREA IS CREATED BY AN ARCHITECTURAL FEATURE,NO ADDITIONAL web wood joists. m SPRINKLER PROTECTION IS REQUIRED,PROVIDED ALL OF THE FOLLOWING CONDITIONS ARE MET; 2. Joist are of depths from 6-16 inches(152-204 mm). LI(a)THE FLOOR AREA SHALL NOT EXCEED 18 FT°(1.7 M') 3. Joist are of spacing from 12-24 inches(305-610 mm)on center. Q (b)THE FLOOR AREA SHALL NOT BE GREATER THAN 2 FT IN DEPTH AT THE DEEPEST POINT OF 4. Joists can be exposed after installation. \ \ jr THE ARCHITECTURAL FEATURE TO THE PLANE OF THE PRIMARY WALL WHERE MEASURED 5. Metal pipe hangers spaced at maximum 24 inches(610 mm)on center 1.55" / 1.66" ALONG THE FINISHED FLOOR. are used. E (c)THE FLOOR SHALL NOT BE GREATER THAN 9FT IN LENGTH WHERE MEASURED ALONG THE 6. Listed residential automatic sprinklers of maximum activation zii -qn Hanger 1" Hanger PLANE OF THE PRIMARY WALL, temperature rating of 155°F(68°C). (d)MEASURED FROM THE DEEPEST POINT OF THE ARCHITECTURAL FEATURE TO THE SPRINKLER .14 SHALL NOT EXCEED THE MAXIMUM LISTED SPACING OF THE SPRINKLER. Tubing Supporti Spacing: (3)THE HYDRAULIC DESIGN SHALL NOT BE REQUIRED TO CONSIDER THE AREA CREATED BY THE 1. Metalt Tubing Support. (Anchor AquaPEX Tubing g Securely Expand and to Support the Tubing,Yet Relaxed ARCHITECTURAL FEATURE. 1. tubing supports designed for plastic tubing shall be used. Enough to Allow the Tubing to Expand and Contract) 2. Do not use supports that will damage the tubing.Inspect metal osupports for sharp edges. 1. Along Horizontal Runs,Install Supports Every 32",if Horizontal Runs are 9 17. NFPA 13D 8.3 LOCATION OF SPRINKLERS. 3. Do not rigidly anchor Uponor AquaPEXmn tubing with supports.Allow Continuously Supported,Place Tubing Supports at Six-Foot Intervals. o • 8.3.1 SPRINKLERS SHALL BE INSTALLED IN ALL AREAS EXCEPT WHERE OMISSION IS PERMITTED BY 8.3.2 enough tubing for freedom of movement to expand and contract. 2. AlongVertical Runs,Install THROUGH 8.3.8. Supports Every Four to Five Fee[,at Each • 8.3.2 SPRINKLERS SHALL NOT BE REQUIRED IN BATHROOMS OF 55 FTz(5.1 Mz)AND LESS Floor and at a Mid-story Guide. W z ro ,p • 8.3.3 SPRINKLERS SHALL NOT BE REQUIRED IN CLOTHES CLOSETS,LINEN CLOSETS,AND PANTRIES THAT �_ ( l z Y MEET ALL OF THE FOLLOWING CONDITIONS: In-line Flow Test v Hi i o (1)THE AREA OF THE SPACE DOES NOT EXCEED 24 FT'(2.2 M'). The In-line Flow Test can be constructed on site. It performs a flow test to / a N 9 o D (2)THE WALLS AND CEILINGS ARE SURFACED WITH NONCOMBUSTIBLE OR LIMITED-COMBUSTIBLE Standard Riser Assembly ensure proper system operation and flow(see Figure F001-8). C\1 10`9 ori MATERIALS AS DEFINED IN NFPA 220,STANDARD ON TYPES OF BUILDING CONSTRUCTION. In a multi-purpose system a single control valve controls both domestic and LIDz w 2 rte. n • 8.3.4* SPRINKLERS SHALL NOT BE REQUIRED IN GARAGES,OPEN ATTACHED PORCHES,CARPORTS,AND fire safety needs. CI I a 'iii; o = .a SIMILAR STRUCTURES Y 'i'-t'O o m`D a '9 Uponor AquaPEX s F-m w m • 8.3.5 SPRINKLERS SHALL NOT BE REQUIRED IN ATTICS WITH OR WITHOUT STORAGE,PENTHOUSE j j EQUIPMENT ROOMS,ELEVATOR MACHINE ROOMS,CONCEALED SPACES DEDICATED EXCLUSIVELY TO AND Tubing z 2 CONTAINING ONLY DWELLING UNIT VENTILATION EQUIPMENT,FLOOR/CEILING SPACES,ELEVATOR SHAFTS, H O ft CRAWL SPACES,AND OTHER CONCEALED SPACES THAT ARE NOT USED OR INTENDED FOR LIVING 7 PURPOSES. Z p Oz a 3 • 8.3.5.1 SUCH SPACES THAT CONTAIN FUEL-FIRED EQUIPMENT SHALL ALSO COMPLY WITH 8.3.5.1.1 OR • z s r(h`' H o 8.3.5.1.2. -_ a a u o F r'-2 Lo UNIT, .1 WHERE THE FUEL-FIREDCTIOEQUIPMENT Q IRED ALL OF THE OCCUPIED AREAS OF THE DWELLING I j �`� ^(� z r?F w u UNIT,NO SPRINKLER PROTECTION SHALL BE REQUIRED IN THE CONCEALED SPACE. V/ O O o-,O i m w o - • 8.3.5.1.2 WHERE FUEL-FIRED EQUIPMENT IS BELOW OR ON THE SAME LEVEL AS OCCUPIED AREAS OF THE N u u u a o.to z o o- Male Threaded Coupling ProPEX Fire O y a, DWELLING UNIT,AT LEAST ONE QUICKRESPONSE INTERMEDIATE TEMPERATURE SPRINKLER SHALL BE w of NI Eli INSTALLED ABOVE THE EQUIPMENT OR AT THE WALL SEPARATING THE SPACE WITH THE FUEL-FIRED Sprinkler Adapter aJ �n o EQUIPMENT FROM THE OCCUPIED SPACE. w o 1"Ball Valve T a! • 8.3.6 SPRINKLERS SHALL NOT BE REQUIRED IN COVERED,UNHEATED PROJECTIONS OF THE BUILDING AT To Hot Water Heater Male Threaded Coupling y 1 > o ENTRANCES/EXITS AS LONG AS THE DWELLING UNIT HAS ANOTHER MEANS OF EGRESS. � Female Threaded H f ,�..,,// • 8.3.7 SPRINKLERS SHALL NOT BE REQUIRED FOR CEILING POCKETS THAT MEET THE FOLLOWING !f,- L.L z Tee with Water a CONDITIONS: _ _ Pressure Gauge CD O O m (1)THE TOTAL VOLUME OF ALL UNPROTECTED CEILING POCKETS IN A COMPARTMENT DOES NOT EXCEED Sprinkler Orifice (Optional) o m 100 FT°(2.83 Ma). s 10 d z . on' p, r (2)THE ENTIRE FLOOR UNDER THE UNPROTECTED CEILING POCKET IS PROTECTED BY THE SPRINKLERS 0 H 1_ ;o u r>w ut ` AT THE LOWER CEILING ELEVATION. E Y Uponor Warning Signs Flow Test 5 m w (3)*THE INTERIOR FINISH OF THE UNPROTECTED CEILING POCKET EXCLUDING DECORATIVE To ensure the s stem g proper fire sprinkler � 0 iy �a m Is,: y provides enou h water forti TREATMENTS IS NONCOMBUSTIBLE OR LIMITED-COMBUSTIBLE MATERIAL. w performance,you should conduct a flow verification test. J ,e o (4)SKYLIGHTS NOT EXCEEDING 32 FT'(2.97 M')SHALL BE PERMITTED TO HAVE A PLASTIC COVER. F•'1 �--I.r't • 8.3.8 SPRINKLERS SHALL NOT BE REQUIRED IN CLOSETS IN GARAGES AND EXTERIOR CLOSETS Note: The NFPA 13D Installation Standard does not require flow = V f y m 9£LE o (REGARDLESS OF SIZE)LOCATED ON EXTERIOR BALCONIES,EXTERIOR BREEZEWAYS/CORRIDORS,OR •- verification. M 9°T o F a w iO ACCESSED FROM OUTDOORS WHERE THE CLOSET DOES NOT HAVE DOORS OR UNPROTECTED " W ~ E z!L?, 5 z m a Main Fire Sprinkler 3 a m PENETRATIONS DIRECTLY INTO THE DWELLING UNIT. _ LL _ Before performing a flow verification test,confirm the water pressures byK o Shut-off Valve o qa x pi E O' i'- 9, -+ : • 8.3.9 SPRINKLERS SHALL BE INSTALLED IN ANY CLOSET USED FOR HEATING AND/OR AIR-CONDITIONING z - contacting the Water and Sewer Department of your local city. Ensure the a O u u�in z EQUIPMENT,WASHERS AND/OR DRYERS,OR WATER HEATERS EXCEPT AS ALLOWED BY 8.3.8. _ available water pressure matches the pressure used in the system design. h in Note: The sprinkler SHEET DESCRIPTION g 18. INSULATION GUIDE LINES PER NFPA 13D. - pri kler plan indicates the most hydraulically remote sprinkler • 9.1.1*WET PIPE SYSTEMS IN AREAS ABOVE 40°F. A WET PIPE SYSTEM SHALL BE PERMITTED TO BE TO BE - (or pair of sprinklers). For test requirements on other sprinklers,consult GENERAL NOTES&DETAILS v • USED WHERE ALL PIPING IS INSTALLED IN AREAS MAINTAINED ABOVE 40°F,INCLUDING AREAS PROPERLY a your local code. INSULATED TO MAINTAIN 40°F. •• A.9.1.1 IN AREAS SUBJECT TO FREEZING,CARE SHOULD BE TAKEN IN UNHEATED ATTIC SPACES TO Note: It is a good idea to notify the fire inspector at least 24 hours prior to .c-r: COVER SPRINKLER PIPING COMPLETELY WITH INSULATION. INSTALLATION SHOULD FOLLOW THE performing a flow verification test. This may speed up the inspection GUIDELINES OF THE INSULATION MANUFACTURER.FIGURE A.9.1.1(A)THROUGH FIGURE A.9.1.1(F) process and eliminate the need to repeat the test for the inspector. SHEET NUMBER SHOWS SEVERALION METHODS THAT CAN O CONSIDERED. THESE ARE FOR MENTIVE PURPOSES ONLY. Note: See"AquaSAFE Flow Test Instruction Sheet"(Provided In 8 CONSULTATION WITH THE GENERAL CONTRACTOR AND/SU OWNER IS RECOMMENDED TO ENSURE PROPER METHODS AND MATERIALS ARE USED TO MAKE SURE 45°F WILL BE MAINTAINED. Contractorsnfors Documentspackage online at www.rofor more information on Flow Test Setup,Assembly,Performing the Test and Troubleshooting. If there are any questions please contact Uponor. -3 © UPONOR - CONFIDENTIAL FO 0 1