Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
SGN2017-00034
CITY OF TIGARD SIGN PERMIT i U Permit#: SGN2017-00034 COMMUNITY DEVELOPMENT Date Issued: 03/20/2017 JIG A RD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2421 Parcel: 1 S126CA01100 Jurisdiction: Tigard Name of Business: Target Business Address: 9009 SW HALL BLVD 100 Applicant/Agent: Brown, Chris Work Description: New signs for Target Permanent: Yes Freestanding: No Freeway: No Temporary: Wall: Yes Electronic: No Billboard: No Balloon: No Banner: No A-Board: No Sign Dimensions: 10x10 Total Sign Area: 100 Wall Area: 11111 Wall Face(Direction): West Sign Height: 21.4 ft. Projection From Wall: 6 in. Illumination: Internal Materials: Arcylic and Alum Electrical Permit Required: Yes Building Permit Required: Yes C Total Permit Fee: $0.00 �S u n C S G N 0 I l - v oo 3 2--- Conditions: This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. A permanent sign must be placed within 90 days from approval date or sign permit shall expire. A temporary sign shall expire 30 days from validity date. A balloon sign shall expire 10 days from validity date. Approved By: /V) •f j3 /I n ' Permittee Signature: i�� � Sign �'• i ED City of Tigard Si n D tR{ COMMUNITY DEVELOPMENT DEPARTMENT • = L;:; ' 0 .,'1)1 TIGARD Sign Permit Application ice;ANNtNu0r7,4,:.i1vttnING SIGN LOCATION REQUIRED SUBMITTAL Address: 9009 SW Hall Blvd Suite #: ELEMENTS City/state:Ticiard, OR Zip: 97223 ❑ 2 copies of elevations on 81/2"x 11" Tenant or business: Target or 11"x 17"pages(Wall sign elevations must include dimensions G 19.e `� of sign and wall face and show the Property owner name: location of sign on the wall. Address: Freestanding sign elevations must City/state: Zip: be drawn to scale.) Phone: Email: ❑ 2 copies of site/plot plan,drawn to scale,on 81/2"x 11"or 11"x 17" Sign contractor: Vancouver Sign Group pages(not required for wall signs) Address: 2600 NE Andresen Rd Ste 50 ❑ List or diagram of all existing sign dimensions and square footage City/state: Vancouver, WA Zip: 98661 ❑ Application Fee Phone: 360-787-8099 Email: C•RTown ova nsi scn ro.ram CCB License #: ti 19 i Expiration date: 1/24/2018 NOTES: • Freestanding signs over 6 ft.in height Contact person: Chris Brown and walls signs of which any element weighs 20 lbs.or more require a building permit for construction. SIGN DATA (Complete all items in this section) If any element of a wall sign weighs 70 lbs.or more,plans must be prepared TYPE (Check all that apply) by a structural engineer. • New sign 0 Freestanding © Electrical • Building permits require 2 sets of ❑ Alteration to 0 Freeway 0Wall construction drawings and,if sign is freestanding,2 copies of site/plot plan existing sign 0 Roof ElOther and 2 sets of engineering must be Sign #: submitted with building permit application. Sign dimensions: 10' (h) x 10, (w) = 100 sq.ft. sign area New sign:100 sq.ft. + Existing sign area 0 sq.ft. =100 Total FOR STAFF USE ONLY Total sign area:100 sq.ft.Ai,111.26 building face sq.ft. = • 89 %of bldg face SClN20 7 °C)(231 Case No.: Height to top of sign: 21.42 ft. Projection from wall: 6 in. Related Case No.(s): Materials: Acrylic and aluminum. $ 201 Fee: Application accepted: Is the sign under 20 lbs.? CI Yes No By: lin (5 Date: 3/ I 11 (Building Permit required if over 20 lbs.) Application determined complete: Direction wall faces (circle one): N S E ® NE NW SE SW /� ?.D Will the sign have illumination? • Yes 0 No By: / /i B Date: 3. / /1 ? If yes,what type: I. Internal ❑ External I:\CURPLN\Masters\Land Use Applications Rev.03/03/2015 City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • www.tigard-or.gov • 503-718-2421 • Page 1 of 2 APPLICANTS NOTE: Person specified as "Applicant" shall be designated"Permittee"and shall provide financial assurance for work. *When the owner and the applicant are different people,the applicant must be the purchaser of record or a lessee in possession with written authorization from the owner or an agent of the owner. The owner(s)must sign this application in the space provided on the back of this form or submit a written authorization with this application. THE APPLICANT(S) SHALL CERTIFY THAT: • If the application is granted,the applicant will exercise the rights granted in accordance with the terms and subject to all the conditions and limitations of the approval. • All of the above statements and the statements in the plot plan,attachments,and exhibits transmitted herewith,are true;and the applicants so acknowledge that any permit issued,based on this application,may be revoked if it is found that any such statements are false. • The applicant has read the entire contents of the application,including the policies and criteria,and understands the requirements for approving or denying the application. I hereby acknowledge that I have read this application,that the information given is correct,that I am the owner or authorized agent of the owner, and that plans submitted are in compliance with the City of Tigard. SIGNATURES of each/vner of the subject property required. G 73(� 3l20 App cant's signature Print name Date Owner's signature Print name Date Owner's signature Print name Date SIGN PERMIT APPLICATION City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • wwwtigard-or.gov • 503-718-2421 • Page 2 of 2 A 1 \:. EXISTING SIGN SCHEDULE - J�� AEXIST'G 132"(11'-0")BULLSEYE (Red) LOGO/29"(2'-5")TARGET(Red)LTRS/150.0 SQ. FT. .., t; 14 QUANTITY: ONE(1) ON FRONT ELEVATION-TO BE REMOVED&DISCARDED NNN ,JItp. , EXISTING 30" (2'-6")CVS pharmacy LETTERS/ 55.66 SQ. FT. Pat,.t ,. 4. '� © QUANTITY: ONE (1)FRONT ELEVATION ... .. 0 / A D EXISTING 72" (6'-0") BULLSEYE (Red) LOGO/57" (4'-9")TARGET/ 155.78 SQ. FT. QUANTITY: ONE (1)ON WEST ELEVATION -TO BE REMOVED & DISCARDED ..,,,N‹ \ • / . . EXISTING 72" (6'-0") BULLSEYE (Red)LOGO/57" (4'-9")TARGET/ 155.78 SQ. FT. E QUANTITY: ONE (1) ON SOUTH ELEVATION -NEW FACES & LED INSERTS r `, Previously Permitted TOTAL BLDG. SIGNAGE: 461.56 SQ.FT. "VI of doe I Z T i14.9111ti — 1eA�� 8 a. ~ IIULJ' ' ri PROPOSED SIGN SCHEDULE 5o LL N a Q 180"(15'-0")BULLSEYE(WHITE)LOGO/ 225.0 SQ.FT. 0 5 - 6 QUANTITY: ONE{1) FRONT ELEVATION-NEW ,_a s 0 t / . 4�' y 14" (1'-2") (Red)ORDER PICKUP LETTERS/ 24.59 SQ. FT. to �i a QUANTITY: ONE (1)FRONT ELEVATION -NEW .t1 © EXISTING 30" (2'-6")CVS pharmacy LETTERS/ 55.66 SQ. FT. / 4 iii ! QUANTITY: ONE (1)FRONT ELEVATION- NEW / MN / O120" (10'-0") BULLSEYE (RED)LOGO 100.0 SQ. FT. QUANTITY: ONE (1)ON WEST ELEVATION-NEW � /r - Y. EXISTING 72" (6'-0") BULLSEYE (Red)LOGO/60" (5'-0")TARGET/ 155.78 SQ. FT. • _ QUANTITY: ONE (1) ON SOUTH ELEVATION NEW FACES & LED INSERT CI • l a • PROPOSED TOTAL BLDG.SIGNAGE:563.12 SQ. FT. * 1 O R "DS • •• i ..: *�, M ` .� w r EXISTING GROUND SIGN REPLACEMENT FACES/EXISTING D/F PYLON SIGN clECEIVE SITE PLAN - NTS in. r \ QUANTITY: TWO (2)FACES REQUIRED MAR 2 0 2017 D GI I Y LAt- I IUHhtu PLANNING/ENGINEERING Revisions: II FEDERAL. n9 R26]316BCNRnAIrr16r 16d[hgpaEmeMd( Proect/Location This original drawing Ma"�" oMMe. A26,3.156WReAinam,6ru,s Account Rep. BOYD HIPPENSTEIL 23-37506-10 is provided as part of a Oceanside.U-Euless,lX-laoaonvak.Tx-Dnawarc,ori p 615.16/W Ray stupe for p to remora 8 replace w,l 10 be!Saye 0 Job Number: p N���� omceLMa,f I73616varcHlteTS A&Dploe,,em Manager SANDRA RAMIREZ planned project RS t i t 6 to RMI1N m Per for D Rorer and is not to be exhibited, CKearolde,Ca-La514gM W•Lauglifn,AZ-Idaho Fails,ID Date. MAY 19, 2016 copied or reproduced Euless,1X-Jacksonville.TX-San Antonio,TX Corpus Clvtm,TX Rt, .Ier,01utetl Drawn By ROBERTO MIJARES/JKJJOR without the written SIGN COMPANY NaMnapoln,IN-Daaw e,OH-Nowak TN-Louisville.Kr Grafton,WI-WIIIondock IL�Tunica.MS Color>Dernt reo In This Renoeriny May NDI Match Actual-;Wished Materials Refer To Product Samples Ful Exacl Color Match Untl�nrfften f etErnntx TC USC ul LIVED Store Number: T0345 1 or 1 1 perm 15 S f o n of www.FederalHeath.com nye CAM/O,-ALTO OS/NLLMEFT Sheet Number. Atlanta,GA-Tampa,FL-Daytona Death,FL•Orlando,FL ID inc. Federal Heath Sign n 4602 North Avenue Oceanside,CA 92056 Client A,oprovaVDate: ALL N.E.C. STANDARDS 9009 SW HALL BOULEVARD g (760)941-0715 Fax 17601 631-5065 ALL IC Ile(TRHAL 3.00$ASP TO COMPLY '.TN V 1 CE AND 23-37506-10-R6 Company, LLC or its Bulldin Quall Signage Since 1901 ARTICLE .Ra Of THE N.E.C. SLAMDARD3, rNCIUDrNG TIGARD. OR 97223 Desl n Number. 9 tyLandlordApprovaVDate: DIEE DEOUNDIND AMO aoxofNc or ALL n�Ns L-3 authorized agent CFHSC • ± 425'-1" A 1lD14," EO j_ E0 0 • I 1 � �I i •0111. 1 ' MN al."1111111 CV &Re e ei 4°C E00r militN -_• -0Mi - S ... .4- i Li. i ... !D!•0icil,.. , E:_n:!:.:;..�.. nT' ., :"I M`_4 I , t^ . II +c rl:::F-e•-sii:,i 41!'1 11 '�:' ,.n:r.:'r ..,r � -fir.•+=a ,_ ���� I+ •'4'. +1 " d { (( .r i .11,Zy:.1 i i I • i • �i S 11 S 11 S tF ll' u;;;':•:-'51,..:*.; ` .:.,-1174.''P- -, a a I°sx; .� :L !o�CF_ ° ` . . ..... .... •.'� )i.) ) .i>ltT_. .i}'+.(lli�..11_r .! SI.Ai •:;11111,, n�r_::Iv. ::n i•,.I I_ '- I ! S -). ' if''' •1 t „ _ 'a m -'•s---ra j' _.. r"e ie?+-��G nv pit Is p 0 n: 1 L .I g.- i•--,7 r. . es r ; 'iik. • EXISTING NORTH ELEVATION - STORE FRONT Scale 1/32"=11-0'I { f, - '- _ie ,t + •• ` + Faf r E , • .. • - ii j, • , .. -, >• • ir + e • 1 ‘� .• • a a _ .- A i ..•...• e : . • • • w f 4 . qic ... . Et ,,,x .. ....vmsivie. r r J04. 41111 — • EXISTING CONDITION NTS iiii FEDERAL Revisions: This original drawing Man�arnBlAy Fawner RI 6116 VAR11 by A 6E•It•16't dig pioneer el( Project/Location: 9 g OLeansMr,U-Eukn,T%-UdOomAe,Tx-DAawac OH R7 6.13.16 BW Rev A kom 16'lo 15' Account Rep. BOYD H IPPENSTEI L s provided as part of a HEATH p6.15.166WRnxapal•D•rE•EwtaEpiE•r710Idi•pa Job Number- 23-37506-10 R4 7.06.16 VA/CH Om Res ANS oles*mem Project AAanager SANDRA RAM I R EZ p armed project omcE LDLauoni: R51116160Ml1K As Par AMS NMM 0 and is not tO be exhibited, °�aNrID`,"-�`�,a:,""-`.tprM•Az-Dah°F'„L,'° Dare: MAY 19, 2016 ED,lx .i acsonNEe,ix-San Antonio nT%-Corpus Christi,TX 86 01 2617 MRMRRevised placement o!Sign C where old Phorma,y loners placed Copied or reproducedEuless, Drawn By. ROBERTO MIJARES/JICIJDR without the written COMPANY Grafton,VA-WElowbrooL.IL-Tunica,MS Colors Depiued On This Rendering May Not Match Actual Fnished Mmehals Refer To Produn Samples For Exact Coln,Match FIEOEKx TD us.ut us7ID 2 or 1 1 permission of urw.rrrihr. ® COMPONENTS ANDE,+N1MINT Store Number:T0345 www.FederalHeath.com ,mentaw-T Sheet Number: 4602 North Avenue Oceanside,U 92056 R Daytona Beath FL Orlando,FL Client AppmvayDeoe `'°°"'°�"'"` 9009 SW HALL BOULEVARD , Federal Heath Sign Atl N.E.C. TTAN DA EDS I{ /(� r^ a//a••��� 1 17601 941-0715 Fax(760J 631-5065 ALL ELECTRICAL SIGNS ARE TO COMPLY WITH LLL.4e AND 23-37506—1 O—RO Company, LLC Dr Its BuildingQuality Signage Since 1901 ApprovaVDate: ARTICLE 6BG OF THE N.E.C. STANDARDS, INCLUDING TIGARD, OR 97223 Design Number. Landlord THE PROPER GROUNDING AND BONDING Of ALL SIGNSaJrhonzed agent ®FHSC • • 12'-3 1/2"(TARGET) 4 11'-0"(BULLSEYE) ' 22'-10 5/8"(B) 4 1'-10"1 f 1'-10"•41 3'-8' 4.4 1'-10." 1'-10.. 4 4 ' ' 3'-1 1/16"(C) { ) 6'-81/4"(D) I I 12'-2 5/8"(E) iiii4 [O " AP CVS pharmacy Q _ * EXISTING 30" (2'-6") RED CVS Pharmacy CHANNEL LOGO & LETTERS T QTY: ONE (1) Scale: 1/4"=1' 0" SCOPE OF WORK: EXISTING SIGN TYPE TO REMAIN AS IS. NO ACTION. EXISTING LOOK NTS 11"Z • GV TARGET • - • 35'-0" O.A. Per Survey 4 - I. EXIST'G 132" (11-0")BULLSEYE (Red)LOGO 6'-0" 27'-10 1/2"± A 29"(2'-5")TARGET(Red) LTRS/ 150.0 SQ. FT. 4 01 J 1) ONE REQUIRED SCALE: 1/4" = 1'-0" A LOGO = 121.0 SO. FT. TARGET = 29.0 SQ. FT. - TOTAL = 150.0 SQ.FT. cO•• () TARGET A c=.= SCOPE OF WORK: REMOVE AND DISCARD EXISTING AND REPLACE WITH NEW SIGN. • • 204 SO FT D © EXISTING 72" (6'-0") BULLSEYE (Red) LOGO/60" (5'-0") TARGET LETTERS Scale:3/16"=1'-0" LOGO = 36.0 SQ.FT. LETTERS = 146.5 SQ. FT. OVERALL TOTAL=204.0 SQ. FT EACH D SCOPE OF WORK: EXISTING SIGN TYPE TO BE REMOVED AND DISPOSED. n SCOPE OF WORK: \ EXISTING SIGN TYPE TO BE REFACED I NEW LED INSERTS I PI FEDERAL RIU16VWOIRn*Iromll'ro,6'Bdt5plaamemol<. Project This Original drawing M'""'�`g"°"� R1fi131fiBWRerArram,fi'la,s. Account Rep: BOYD HIPPENSTEIL 23-37506-10 is provided as art of a Oceanside.CA Euless.TX-�awwNNe.7u-Delaware.on 6.iS.lfi BW Rev scope for D to remote 6 replace ref 10'6ullseye Job Number p HEATH °^� R�t��6r�ra,RF.siBeaen�at.m.a1 Project Manager SANDRA RAMIREZ planned project 8511.1616 PAM k Per AMS Rants and is not to be exhibited, cos °�'n=°e.Ca aS gas.P .Laughlin.AZ'aarC Falls,ID MAY 19, 2016 EIam,TX-JatlaorMee.7X.San MtadD,TX-Carpus Chrlso.TX 760-.20I774/17 Revised plowmen]of Sign(where old Pharmacy fevers placed0 Date. _ copied or reproduced SIGN COMPANY Drawn Br. ROBERTO MIJARES/JK/JDR em,IX.dN,w-naavlaaow-IonIo.T .C,sodol,Kr without the written Grafton,WI-Willowbrook,K.Tunica,MS Colors Depicted In INNS Rendering May Not March Actual Finished Materials Rete,To Product Samples For Laact Color Mal cn ! ELECTRICAL io USE U.L.LDS® Store Number:T0345 3 Of 11 perm I s S I 0 n O t www,FederalHeath.com Manta, R Orlando, UL A �� Sheet Number. • Y.eDp10fiiInc. ALL N.E.C. STANDARDS 9009 SW HALL BOULEVARD Federal Heath Sign 4602 North Avenue oceanside,CA 92056 Client ApprovaVDate: g (760)941-0715 Fax 1760)631-5065 ALL ELECTRICAL SIGNS ARE TO COMPLY w ISH 0.l.16 AND 23-37506-10-R6 Company, LLC or its BuildingDuan Signage since 1901 Landlord ARTIEL[ .aa OF THE N.E.C. STANDARDS, INCLUDING TIGARD, OR 97223 DesignNtxnber landlord Approval/Date: THE e[Crap GROUNDING AND BONDING OF ALL SIGNS. authorized agent ®FHSC ± 424'-7" 0'41- "Y 3'-ON 1 tT�t`. 3333 .. G _ 12' 6 15' 0" r _ ._.,,, NEW 47 I ,� SIGN TYPE r w #, � .. „ ; ; ,C I Oi 12'10` +S'-10' I ,� ',:-...r.-',: r,nl: I1 l I 1� �..•. ,. - -- ` — t 5'-0” O _-33_33_ _.- -.. 333 3 . — • L - T rD ��'.1l'Sph;rn»cy I '�I .. >- 1'11- i t 14 'MP N n + • I 1 l I , 12'-81/2"_• 14 :... I tit wsri{ I~hIf+Pg. I PROPOSED NORTH ELEVATION SEE ENLARGEMENT DETAILS SEE ENLARGEMENT DETAILS NEXT PAGE NEXT PAGE Scale 1/32'=1 P-0" t NEW D4'-10"--1 10'-0" SIGN"WE " 1I I '1crb -- N , CI — : 10'-0" " e - N _._ __ ._—_-_ii tl _ iilliS NOM�+rrr+r.. s PROPOSED WEST ELEVATION Scale 1/32"=1'-0" ± 424'-7" 4 1 • h'L : ' �1 I N • c-0": •Rom 1 1 ! MI i I .t. I 333 ,,■,. _ - .. - PROPOSED SOUTH ELEVATION Scale 1/32"=1'-0" Revisions FEDERAL This ori .nal drawin MNluracnmmq Facilities RI 6.13.6 SWR Res A horn Ilio 161 ch placement of C Project/Location: 9 g R2613.16BWRerAlrom6io15' 4P Account Rep: BOYD HIPPENSTEIL 23-37506-10 is provided as part of a Oceanside.U-Euless.TX-Id(kiarpnik.Ix•Dewwam,OH116 6.15.16 BW Res gape for D la[more B replace w/10 hullseye JOC N W i1 bc' planned project HEATH gas NVocrom 1511.1.16VA/CHRevSig A13placemem Project Manager SANDRA RAMIREZ O and is not to be exhibited. R511.16.16RMpKAsPerAMSNoIeI MAY 19, 2016 Oceanside.Ca-IasVegas,M/-Laughlin,AZ-IadlwFNb,ID Date. copied or reproduced Euless.is Asdcsoo,,ii is-Me Antonio,TX Corpus cnros is R6 01 26.17 VA/1K Reseed placemer SI Sign C nhere cid Phmmory leueh aimed Drawn By ROB ERTO MIJAR ES/JK/JDR SIGN COMPANY Indianapolis IN-DT'a`"are o" knwvmeTN-Louwnel(Y wan out the written Citation.WI-Willowprook,II luni(a,MS Colors Dep:cteo Ir This Renserrny M. No:MasCh ACIJai Finiseeo Ma l erials Kele/10 Ploduci Samples So,txaci Coro,Match Uhderwrfeeo 2 ELECTRICAL To USE U.L.MOD Store Number. T0345 4 11 permission of www.FederalHeath.com y1 cj COMPONENTS ANDsmularT Sheet Number: v Atlanta GA•Tampa.Ti-Daytona beach,FL-O0ando,Ft L"bOpgollee 1110. i ALL N.E.C. STANDARDS Federal F�e a t it Sign 4602 North Avenue Oceanside,CA 92056 ClientApproval/Date: `- 9009 SW HALL BOULEVARD Company, LLC or its All ELECTRICAL THE AS!TO COMPLSTAND RDS.WITH INC eR AND Design Number. 23-37506-10-R6 (7601 941-0715 Fax 17601 631-5065 ARTICLE aaa OF TME N.E.0 STANDARDS.O INCLUDING SIGNS TIGARD, OR 97223 g authorized agent ©FHSC Building Quality Signage Since 1901 Landlord Approval/Date. THE.RnPeR 4.OUNOlN4 AND BONDING Dr ALL srDNs • _ _ _ — - I . u � 11 , NEW .�,, �, . SIGN TYPE , , 413/ 112 71 1 '-6"dri 15,_0,1 , N r iN rePt , 1 B 121-10" ; 51-10" ,t- r --41).t ' I imsiminim 0ti © ---- 1'-11" —order pickup - �_ �� I �, n, ; N I 12 8 �2 ..- mi; E. 1 IIuaIu 1 +1 NI in ENLARGEMENT DETAILS - PARTIAL NORTH ELEVATION 1 SCALE: 1/16"=1'-0" �, _ — r NEW 1 V 4 -1011 -- 10 -0" SIGN TYPE i-- , 221-3 5/8" • TT r Li r. iir Mini EC 1 © 1 101.0" N ; ll 5'-6"#12'-6" 11Pphernticy in 1 +I i 4 ± 111.511 ENLARGEMENT DETAILS - PARTIAL NORTH ELEVATION 2 ENLARGEMENT DETAILS - PARTIAL WEST ELEVATION - SCALE: 1/16"=1'-0" SCALE: 1/16"=V-0" Iri FEDERAL Revisions Manufacturing Fadlltles RI 6416 YA/CM RnAlrom 14'ie 16'Bthp placement calf prpjecr/Location,, This original drawing OcearWde,CA-Eules,TX�JarloonNae,1X-Delaware,OH RI6116W RevyARom 14x15' Account Rep BOYO HIPPENSTEIL q G c H 836-15.16 BW RevampebrD«"move&replacew/10'bulline Z3-37506-1O p anned as part e1 a O Job Number. planned project HEATH II 7.06.16VIM WS*AiDp1E"mnI M r SANDRA RAMIREZ and iS not to be exhibited, °"'n a'°° Rs n.1 f 16 R6VJR As nr Ars them Manager MAY 19 2016 fXearome.Ca-las Vegas,N✓-uayrn,AZ Falls,ID Dare. , copied or reproduced awns.Dl Jatl0mville,7X-SraAntonio.1X-Caae dew TX R6 01 26 17 VIVR Revised placement of Sign(where old Pharmacy leder plated Drawn By. ROBERTO MIJARES/JK/JDR without the written SIGN COMPANY haienepona IN Delaware,OH-Er e'TM ' -'"+La '"e, 5 Grafton,un-Wabwa,wwl IL-Tunica,NS Colors Depicted In This Rendering May Not Match.Actwl Hnished Materials Refer To Product Samples for toad,Color Match ®fin ® E CENCAL TO USE U.L..LIMO Store Number:70345 Sheet Number: 01 11 permission of www.FederaiHeath.com Adana w T Daytona BeachTL 041000,FL +�ppMpyy�pAp [aRteorvelvtsTroE/1nLaeREr Federal Heath Sign 4602 North Avenue Oceanside,CA 92056 Tampa,FL Client Approval/Date: "L` N.`` S 9009 SW HALL BOULEVARD g 1760)941-0715 Fax 17601 631-5065 ALL ELECTRICAL SIGNS ARE TO COMeLT WITH U.L.RR AND 23-37506-10-R6 Company, LLC or its Building cauda Signage since 1901 ARTICLE ADO OF THE M.E.C. STANDARDS, INCLUDING TIGARD, OR 97223 Design Number g ryLandlord ApprovaVDate: THE PROPER GROUNDING AND EOMDrMD OF ALL TIDNLauthorized agent. OFHSC I 1iON-STAN1)AlHD MATERIAL FINISH COLORS 4 ITE OVERALL SIZE B WHITEaTucLns WHITE Sloan While LED Acrylic Returns Faces Retainer/Trim-Cap Illumination 4— C —►.— D —.w-- E ►. F --p4— G —► 6„ SPACE MAXIMUM 1" k SPACE MAXIMUM 1" r MINIMUM 1/2" - - MINIMUM '/" 6" WALL ,1 .080 ALUMINUM FILLER I �,. INTERIOR PAINTED WHITE • if wING'"1�' .063 ALUMINUM RETAINER ` ,k ELECTRICAL AL PANEL it�' f MINIMUM.090 ALUMINUM BACK - L PIGMENTED ACRYLIC FACES a' 9, l e- 7 ( . 1;: / I w SLDAN LED , '''1) , A h"ELECTRICAL BEYOND SIGN w a' LOCK-ABLE DISCONNECT BY INSTALLER. SWITCH BY OWNER-WIRED 11 `�_; INSTALLER TO PROPERLY SEAL WAIL. — BY ELECTRICIAN i }L+�" SEALER:BASF-MasterSeal NP 150 (1 PER CIRCUIT) I (ii,µ �. —� �J "+TL ALL MOUNTING HARDWARE(INCLUDING SPACERS) �, Box BY INSTALLER — e■ TO BE SUPPLIED BY:INSTALLER 4y� C, C* iii, 1. ,✓ \\ \. �. `� POWER DISTRIBUTION BOARD MINIMUM 318"STAINLESS STEEL MOUNTING HARDWARE r / ., 4 BY FEDERAL HEATH \\ .yam 24 V CUSS TWO POWER � r � � 410.1%. ,•Y~ (2)-WEEP HOLES PER LAW SPOT .i --':-• SUPPLY,SUPPLIED BY: �.,-'. FEDERAL HEATH _ ____ - � I• = MOUNTED BY: SUB-CONTRACTOR N� E. ' ^CLASS 2 SECONDARIES TO DISTRIBUTION BOARD l-` TO BE RUN THROUGH CONDUIT SUPPLIED BY L�ih,,IIuuuuuuuunnuuuuuum nnutouu t "ntnunu"nunuuuuuWc \�_ __ L�' INSTALLER AND WIRED BY INSTALLER. * --- I DISTRIBUTION BOARD AND POWER SUPPLIES iSUPPLIED BY FEDERAL HEATH SIGN CO. © LOGO/WALL DETAIL NOT TO SCALE END VIEW (Generic) CUSTOMER TO PROVIDE NEW L REMODEL CONSTRUCTION Q ACRYLIC FACED INTERNALLY ILLUMINATED "BULLSEYE" DEDICATED BRANCH CIRCUITS FOR BEHIND THE WALL BACKING AND SIGNS ONLY PER NEC CODE 6003 ACCESS IS REQUIRED FOR THE INSTALLATION ALL BRANCH ORNITS SHALL BE DEDICATED TO OF NEW SIGNAGE CUSTOMER TO FORWARD SIGNS(INCLUDING GROUND AND NEUTRAL)AND :APPROVED SIGNAGE DRAWINGS TO THE ON SHALL NOT RE SHARED WITH OTHER LOADS SITE CONTACT TO INSURE THAT THE REQUIRED MANUFACTURE AND INSTALL CHANNEL LOGO AS SHOWN AND NOTED ELECTRICAL REQUIREMENTS PROPERLY SUED GROUND WIRE THAT CAN BE PROVISIONS ARE MADEDURING CONSTRUCTION, TRACED BACK TO BREAKER PANEL IS REQUIRED. PRIOR TO THE SIGN INSTALLATION. Total: 0.0 Amps INSTALLER REQUIREMENTS INSTALLER Ea1MRERIENIS FOR LIPS WALLS SIGN TYPE A B C D E F G RETAINER SOFT. QTY \--f - ALL MOUNTING HARDWARE, SECONDARY IT IS THE RESPONSIBILITY OF THE INSTALLATION WITO PROVIDE AY WALL SPACERS Weight: '�I, L1bs BYRING THEND NSTALTLATIDN [ONTRACTITS ARE TO BE PRIOR NEQUIREDCONTRAOR 10KEEP EIFSWALLMATERIAL FOM 180 BULLSEYE-W . 15'-0" i 15'-0" 2'-6" 2'-6" 5'-0" . 2'-6" 21-6" 2" 225.0 1 ( 1 ) 120V 20A Circuit Required. ALL PENETRATIONS IN THE WALL ARE TO BE BEING COMPACTED DURING INSTALLATION OF SEALED WITH SILICONE AND TO BE WATERTIGHT. ANY MOUNTING BOLTS REQUIRED FOR SIGNAGE ALL BRANCH CIRCUITS SHALL BE _ DEDICATED TO SIGNS(INCLUDING ANY DEVIATION FROM FEDERAL HEATH GENUAL NOTE GROUND AND NEUTRAL)AND SHALL REQUIREMENTS MAY RESULT IN DAMAGE •INSTALLER SHALL VERIFY WALL CONDITION IN THE FIELD TO OR IMPROPER OPERATION OF SIGNAGE, •TYPE,SIR MID MUMMAOFFASTENERSTOBEDETEBMINED. NOT BE SHARED WITH OTHER LOADS. •CAUSING DELAYS AND ADDITIONAL COSTS. •ALL DOLT HOLES TO BE DRILLED OR PUNCHED. •ISOLATE ALL ALUMINUM FROM STEEL I Fa I FEDERAL Revisions This original drawing ,�„x, Dad RI613.16BCHvAAhow 'to1S LARplDemeEel( Account Rep BOYD HIPPENSTEIL Project/Location R2613.16BWRevAAoml6'to15 23-37506-10 's provided as part of a onansae.cA-ems.Tx-�aaa"Lie,n Delaware,off LT 6 15.16 BW Rev moot lot D N Meat 0 rep"ce"/iG Raw. Job Number plannedproject HEATH 14706ASP, MSNeI"amm, SANDRA RAMIREZ °as. V-La " RS 1 06166 WUHR As Per AMI Nee ggUect Manager Ocrawde,ca.us Vey,>-NV- tions'e,K-WOO rah,to and is not to be exhibited. tuless.rx- TxSari MtoNa.Ix-coryus cnnm,ix R6012617VA/1K Revised p"amenl of Sign Cwhere old Pharmory letters plied0 Dare: MAY 19, 2016 copied Or reproduced SIGN COMPANY Drawn BY ROBERTO MIJARES without the written Indianapolis,TX-Jacksonville-Delaware,OH-Antonio. I - .t�"t,,,rc.KY i J K/J D R Granas Viii wansa."w,E Luau.MS Colors Depicted In This Rendering May Not March Actual Finished Materials. Rete,To Product Samples Fol Load Colm Match ®woman O �,no yyi.0 '.s' Store Number:T0345 6 Of 1 1 permission of wwu'.FeOera)heath corp A"a"a,Gn_r�,,R Dayona9eam,R oanm,Fl n ALLLW�ONE,C STANDARDS Sheet Number: 4602 North Avenue Oceanside,CA 92056 Client ApprovaVDate: L�arwwsl�• M.E.C. STANDAEDS Federal Heath Sign 17601 941-0715 Fax(7601 631-5065 ALL ELECTRICAL SIGNS ARE TO COMeLr WInD U 1 ••AND 9009 SW HALL BOULEVARD BuildingOual Signage Since 1901 'seaARTICLEe EN OF TN. N.!AN S S. INCLUDING TIGARD, OR 97223 Design Number 23-37506-10-R6 Company. LLC or its nYLandlord Approval/Date: TN,REOPEN ,..AND•ONDINE Dr ALL SJDNt authorized agent. A2FFISC • SPACE MAXIMUM 1" M ` B • 5 WALL MINIMUM 1/2" I, Si..• • 411 order H .. 1 .040 ALUMINUM FILLER . PRE-FINISHED ALUMINUM ; I [ . picku I EXISTING C PANEL A I t'TRIM CAP `'_+ TRICAL MINIMUM.063 ALUMINUM BACK Ialtil-J. s I — • I _—_I PIGMENTED ACRYLIC FACES `' I l GE LED ACRYLIC FACED INTERNALLY ILLUMINATED CHANNEL LETTERS "ELECTRICAL BEYOND SIGN 11•.._ n LOCK-ABLE DISCONNECT BY INSTALLER SWITCH BY OWNER-WIRED INSTALLER TO PROPERLY SEAL WALL I I— _ BY ELECTRICIAN. SEALER:BASF-MasterSeal NP 150 it • 1, , 11 PER CIRCUIT) 'r - ; I MANUFACTURE AND INSTALL CHANNEL LETTERS AS SHOWN AND NOTED ..:41.4. J-BD0BYINSTALLER ALL MOUNTING HARDWARE(INCLUDING SPACERS) l.� TO BE SUPPLIED BY INSTALLER 5I MINIMUM 3/8'STAINLESS STEEL MOUNTING HARDWARE i POWER DISTRIBUTION BOARD ---___. J C`•.1. BY:FEDERAL HEATH Sc : , v SIGN TYPE A B C SQ.FT. QTY SUPPLY,SUPPLIED BY: 24 V CLASS TWO POWER I Weight: 11lbs or 1 WEEP HOLES PER LOW SPOT FEDERAL HEATH ! — . MOUNTED BY: SUB-COMPACTOR OPU14-REMOTE-R ' 1'-2" 12'-10" ' 1'-11" 24-59 1 ---- lb per element. CLASS 2 SECONDARIES TO DISTRIBUTION BOARD f.-. .54.,4: TO BE RUN THROUGH CONDUIT SUPPLIED BY ''.,, rI 111I1111111111e1NNI11M11111111rM A1IIL11111IIH11I1111111IIG11It11111111110 ! r• INSTALLER AND WIRED BY INSTALLER. MATERIAL FINISH COLORS DISTRIBUTION BOARD AND POWER SUPPLIES SUPPLIED BY FEDERAL HEATH SIGN CO. ill_LOGO/LETTER WALL DETAIL NOT TO SCALE MP#82074LVG •2793 LD Red I� 111s r (Generic) (FULL GLOSS) ■Modified Acrylic IIRed 111Sloan Red LED (AlWglas or Eguio-) PC air' Returns Faces Trimcap/Relainer Illumination '.' — " j:, CUSTOMER TO PROVIDE NEW&REMODEL CONSTRUCTION NOTE: 1 i..; DEDICATED BRANCH CIRCUITS FOR BEHIND THE WALL BACKING AND SIGNS ONLY PER NEC CODE 6005 I ACCESS IS REQUIRED FOR THE INSTALLATION • WALL IS TILT UP CONCRETE AND THE WALL COLOR IS SW 6121. '- ALL BRANCH OMITS SHALE BEDEDICATED TO OF NEW SIGNAGE. CUSTOMER TO FORWARD SIGNS(INCLUDING GROUND AND NEUTRAL)AND APPROVED SIGNAGE DRAWINGS TO THE ON • ELECTRICAL CIRCUIT REQUIRED. , SHALL NOT BE SNARED WITH OTHER LOADS. SITE CONTACT TO INSURE THAT THE REQUIRED END VIEW ELECTRICAL REQUIREMENTS PROPERLY SIZED GROUND WIRE THAT CAN BE PROVISIONS ARE MADE DURING CONSTRUCTION. TRACED BACK TO BREAKER PANEL IS REQUIRED. PRIOR TO THE SIGN INSTALLATION Total: 0.0 Amps INSTALLER REQUIREMENTS NISTALLER REQUIREMENTS FOR EIFS WALLS ALL MOUNTING HARDWARE, SECONDARY IT IS THE RESPONSIBILITY Of THE INSTALLATION WIRING AND CONDUITS ARE TO BE PROVIDED CONTRACTOR TO PROVIDE ANY WALL SPACERS / BY THE INSTALLATION CONTRACTOR. REQUIRED TO KEEP EIFS WALL MATERIAL FROM ( 1 ) 1 20V 20A Circuit Required. ALL PENETRATIONS IN THE WALL ARE TO BE KING COMPACTED DURING INSTALLATION OF SEALED WITH SILICONE AND TO BE WATERTIGHT. ANY MOUNTING BOLTS REQUIRED FOR SIGNAGE ALL BRANCH CIRCUITS SHALL BE __ . • ,. •' DEDICATED TO SIGNS(INCLUDING ANY DEVIATION FROM FEDERAL HEATH MIA/NOTE GROUND AND NEUTRAL)AND SHALL REQUIREMENTS MAY RESULT IN DAMAGE .INSTALLER SNAIL WY WALL CONDITION IN THE HELD TO OR IMPROPER OPERATION OF SIGNAGE, •nn,SUE ANO NOM1EA OF FASTENERS TO BE DETERMINED.NOT BE SHARED WITH OTHER LOADS. CAUSING DEUYS AND ADDITIONAL COSTS. •ALL SOLT MOLES TO Of DRILLED OR PUNCHED. •150LATE ALL ALUMINUM FROM STEEL. xc}Naa^a1APaP v -. Revlsi II FEDERAL BLESS ` This original drawing R16.BI6VA/ChReTAImmU'rol6'trh placement ACCOt1ntR BOYO HIPPENSTEIL T provided as n of a Manufacturing Fa AMR. Rp Project/Location. 23-37506-10 R2 613.16 8W Rev A from 16'Io 15'. Oceanside,G-Euless,Tx-�adDorNele,TX-neuware,off A3 615.161W Row sap lo D to remaT t replete old l0 bullle7e 0 Job Number, HEATH � R470616VA/CHRoo Sign ABDphoemenl. Project Manager SANDRA RAMIREZ planned project 1t51116.16RM/1KA:PerMISNores MAY 19, 2016 and is not to be exhibited, Oceanude,Ca U5 Vegas,NN-Laughlin AZ-Who Fells.A Euless.Tx•JadDomMle,Tx•San Antonio.Tx-Corpus Oo1A,TX 86012617 VA/JR Revised platen,. on(where old Phormoty levers v.. Drawn By ROBERTO MIJARESJ 'JDR Date copied or reproduced writtened SIGN COMPANY 'n"ran o1o.IN-p�e,OH-KKnowNeIN Louisville,KY K without the Garton,WI-wnawrook.IL-Tunica.MS Colors Oepkted In This Rendering May Not Match Actual Finished Mate"ais Refer To Product Samples For Exact Color Match a r.c,,,ID use u.L.T® Sheet Number: 7 O, 1 1 e r m I S S I o n of www.FederalHeath corn eh n ooEawPmIfEANON/ALLfa� Store Number: T0345p Atlanta GA-Tampa,F7-Daytona Beam.FL Orlando, ALL N.I.C. STANDARDS Federal Heath Sign 4602 Norm Avenue Oceanside,CA 9Z056 Client Approval/Date: LiOor"01N""`' 9009 SW HALL BOULEVARD g (7601 941-071 5 Fax(7601 631-5065 ALL ELECTRICAL SIGNS ARE TO COMPLe•9TH U.L.41 AND Company, LLC or its Building Oua1 Signage Since 190T ARTICLE Loc or THE N.E.C. Sr E. INCLUDING TIGARD, OR 97223 Design Number 23-37506-10-R6 9 l 9 7 Landlord ApprovaVDate: a GIER •N4 AND STNDING S. ALL SIGNS authorized agent. ®r-HSC • MATERIAL FINISH COLORS e ► MP#82074LVG 2793 LD Ree 1111 (FULL GLOSS) ■ Rad a or I ■ Red 1111LE1D Returns Faces Trimcap/AeWaer IHumfnaHoe '-- C —11-4-- D — E 104 F — G . 6" SPACE MAXIMUM 1" iSPACE MAXIMUM 1" MINIMUM 1/2" MINIMUM 1/2 6'I,I+WALL` /1 .080 ALUMINUM FILLER ._ PAINTED:WHITE •• - " et— -L. IM' i EXISTING -- ,,• - Pt III i .063 ALUMINUM RETAINER ELECTRICAL tic PANEL I'C, MINIMUM.090 ALUMINUM BACK '�� `#' 'I' PIGMENTED ACRYLIC FACEAH S • yi- Ri frilika ' SUDAN LED r`r r'" I. ur A • Yz'ELECTRICAL BEYOND SIGN r a ^' � LOCK-ABLE DISCONNECT .: BY INSTALLER. SWITCH BY OWNER-WIRED r INSTALLER TO PROPERLY SEAL WALL. BY ELECTRICIAN • �� SEALER:BASE-MasterSeal NP 150 (1 PER CIRCUIT) ..r PIM J-BOX BY INSTALLER ALL MOUNTING HARDWARE(INCLUDING SPACERS) 1 TO BE SUPPLIED BY:INSTALLER POWER DISTRIBUTION BOARD— n MINIMUM 3/6"STAINLESS STEEL MOUNTING HARDWARE r - BY FEDERAL HEATH• _ is i ' i �' j = 24 V CLASS TWO POWER # = SUPPLY,SUPPLIED BY. . , (2)-WEEP HOLES PER LOW SPOT - I FEDERAL HEATH — = MOUNTED BY: SUB-CONTRACTOR t- -- -- -- t`r CLASS 2 SECONDARIES TO DISTRIBUTION BOARD ,_�_ ' a. TO BE RUN THROUGH CONDUIT SUPPLED BY '^rr,Ililn11 I III l,lul�l.,III. INSTALLER AND WIRED BY INSTALLER. 4. * aisDISTRIBUTION BOARD AM)POWER SUPPLIES SUPPLED BY FEDERAL HEATH SIGN CO. . LOGO/WALL DETAIL NOT TO SCALE END VIEW (Generic) r CUSTOMER TO PROVIDE NEW i REMODEL CONSTRUCTION 0 ACRYLIC FACED INTERNALLY ILLUMINATED "BULLSEYE" DEDICATED BRANCH atom FOR ADEQUATE BEHIND THE WALL BACKING AND SIGNS ONLY PER NEC CODE MILS ACCESS IS REQUIRED FOR THE INSTALLATION AU.IRANCH CIRCUITS SHALL SE DEDICATED TO OF NEW SIGNAGE. CUSTOMER TO FORWARD Weight: 125Ibs SIGNS(INCLUDING GROUND AND NEUTRAL)AND APPROVED SIGNA6I DRAWINGS TO THE ON SHALL NOT IN SNARED WITH OTHER WADS. SITE CONTACT TO INSURE THAT THE REQUIRED F MANUFACTURE AND INSTALL CHANNEL LOGO AS SHOWN AND NOTED ELECTRICAL REQUIREMENTS PROPERLY SIZED GROWl)WIt THAT CAN BE PROVISIONS ARE MAE DURING CONSTRUCTION, TRACED BACK TO BREAKER PANEL SREQUIRED. PRIOR TO THE SIGN INSTALLATION. „ Total: 0.0 Amps INSTALLER REQUIREMENTS INSTALLER REQUIREMENTS FOR EIFS WALLS NOTE. ALL MOUNTING HARDWARE, SECONDARY ITSTIERESPONSIBILITYOFTHEINSTALLATION SIGN TYPE A B C D E F G RETAINER SQ.FT. QTY WIRING AND CONDUITS ARE TO RE PROVIDED EONTRACTOR TO PROVIDE ANY WALL SPACERS • BLOCK WALL BY THE INSTALLATION CONTRACTOR. MUMS TO KEEP EFS WALL MATERIAL FROM , 120 BULLSEYE-R 10'-0" 10'1° F-8° EMI 1'-8" 1'-13" P 100.0 1 • 277 VOLT ELECTRICAL ( 1 ) 120V 20A Circuit Required. AU PENETRATIONS IONSIH WALL rtSWI SIAND WA ERT MING COMPACTED SUNORANY NTING BDLTREEOUI GNAGE ALL BRANCH CIRCUITS SHALL BE DEDICATED TO SIGNS(INCLUDING ANY DEVIATION FROM FEDERAL HEATH SEVERAL NOTE GROUND AND NEUTRAL)AND SHALL REQUIREMENTS MAY RESULT IN DAMAGE •msti wnt RIAU WPM eauCOMMCOIN TKE FILO. NOT BE SHARED WITH OTHER LOADS. TO OR IMPROPER OPERATION OF SIGNAGE, •�,IO MIS TI BE HBe OH p CAUSING DELAYS AND ADDITIONAL COSTS. • •ISOLATE ALL ALUMINUM FROM STEEL ri FEDERAL Res/worts. R16.13.16CRevAAom16''ID16'8thedotemen,DiC This original drawing Manufadlnno Facades: N Account Rep- BOYO HIPPENSTEIL Project/Location: q p G i 4 9 OaeND,°e,G-Euless,D(-latl°DrNNe,Tx-DeYware.OH R16.13.16aWRevAlroml6'1a15' �� 23-37506-IO is provided as part of a HEATH R3 6.1566 BW Rev scope D ID remme B replete w/10 bulhere O Job Number. planned project R47.06.16VAICH BWRevevSien Dlere placement Project Manager: SANDRA RAMIREZ and is not to be exhibited, Celoado"' 85111616RW1RkPerAMSNares MAY 19, 2016 (')t�NnLde.U-LaS veeas,NvlaughM,AZ FRbJD Date. copied or reproduced EL5.Tx.ladODnwne.Tx-Sa,Antonio.TX-Corpa,Ch,isti,e tiU2o17VA,rkev.:.rpmogle n•o•Slyntwhere aldFlummery!wets pieced Drawn By. ROBERTO MIJARESJJK/JDR without the written SIGN COMPANY Indianapolis.IN-Delaware,OH-KnWNMk TN-LDIrNiee,KY Grafton.WI-WNowtrooE IL.Tunica MS Colors Depicres in This Rendering May Not Match Actual Finished Materials Refer To Product Samples For Exact Color Match Undommt•R ( QKT�q TO USE ut,.STm Store Number 10345 8 Of 11 permission O f www.FederalHeath.com nuc �,�1O1ef1S1,DMgT Sheet Number: 4602 North Avenue Oceanside,C A 92056 Atlanta.CIA Tampa,Ft-Daytona BeaCr.FL.Orlando.F Client ApprovaVDate: Laboratories Inc ALL N.E.a a T s Federal Heath Sign 1760)941-0715 Fax(7601 631-5065 A�� ALL ELECTRSCAL SIGNS ARE TO COMPLY WITH u.l.IR AND 9009 SW HALL BOULEVARD Company, LLC or its BuildingQuality Signage Since 1901 L p V ARTICLE •DO Of THE N.E.C. STANDARDS. INCLUDING TIGARD, OR 97223 Design Number: 23-37506-'1O-R6 tYLandlord. rova Date E PROPER GROUNDING AND RONDOS°Of ALL SIGNS authorized agent. OF-HSC E B -F- D G H I J — K 6; _ .,, SPACE MAXIMUM 1" L MINIMUM 1/2'' 5' . --1r, -- I,. r A R G IE Ili ; 7 ii.:i $may A C DYa4, 7. rte`". •y4i L ® REFURBISH EXISTING LETTER SET END VIEW SCOPE OF WORK: MANUFACTURE AND INSTALL NEW ACRYLIC FACES AND LED INSERTS MATERIAL FINISH COLORS SIGN TYPE A B C D E F G H I J K RETAINER AMPS SQ.FT. MP*82074LVG logo/lerttels CIRCUITS otters ■ (FULL GLOSS) ■2793 LD Red Modified Acrylic 1 Red ■Sloan Red LED (AltuMas or Equiv.) LL72/60H-R 6'4 6'4' 5'-0' 27-4" 34'4 81/4" 1'4 1'-0" r-0" 1'41' 1'-0N 1"REL I B.Oa/1 dr. 36/146.5 Returns Faces Trimcap/Retaieer Illumination NOTE: • RUBBING REQUIRED NOTE: • CONCRETE WALL • • 277 VOLT ELECTRICAL Revisions: ®•' ' 1 I FEDERAL. RI Rey A Alrn 1'io 116 B del placemen al Pr This original drawing N„n, Bio AccountRep BOYD HIPPENSTEIL oJea�Locauon. g g R26.13.16BN'RerAharrl6'lols'. 23-37506-10 a provided as rt of a oQawx,cn-Eurss,IX-iaoDwNac.7k Delaware,OH R3 ISIre ID bull>eTe. Job Number. HEATH R410616VA/CH Rev Sign 6tiIlptn<emem SANDRARAMIREZ planned project oas,NV- nons� Project Manager0 R511 1616 RM/Js k Per ANS No1Es and is not to be exhibfted, oma woe. -Las vegFz.N� ��9mm. -aanD Falls. MAY 19, 2016 guess.Tx•is on Ee.Tx Pion rnmrwo,re-cords coney.ix R6 01 26 U VA/JK Revised placement of Sign(where old Pharmacy loners placed Dace. copied or reproduced SIGN COMPANY Drawn By ROBERTO MIJARES/JK/JDR lndurDpdtLlN-De,T e.OH TNotau con KY without the written Grafton,WI-Wlnowbmox.u-Tune..MS Colors Depicted to This Rendering May Not Match Actual finished Materials Refer To Product Samples For Exact Color Mato- I® \ !1[C1 KAL TO USE uL LISTEDpermission of www.FederalHeath.com U n ALL N N.E.O. ST Store Number: T0345 Sheet Number: 9 01 11 Marna,GA-Tampa,FL woo.Beam.Ft•Orlando,FL •l r Laboratories let. ALl N.E.C. STANDAeDS Federal Heath Sign 4602 North Avenue Oceanside,CA 92056 Client ApprovaVDate: 9009 SW HALL BOULEVARD (760,941-0715 Fax 1760(631-5065 ALL ELECTNCAL SIGNS ARE TO COMPLY WITH a L a6 AND 23-37506-10-R6 Company, LLC Or its Building Ouallty Signage Since 1901 Landlord ApprovaVDate: "�:'.:oe..°a o��orN.E.C. o':b`:o:°��°o,INCLUDING ",`�D'„; TIGARD, OR 97223 Design Number authorized agent ®FFISC