Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
SGN2017-00032
CITY OF TIGARD SIGN PERMIT i71 I Permit#: SGN2017-00032 COMMUNITY DEVELOPMENT Date Issued: 03/20/2017 TI i;ARI) 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2421 Parcel: 1 S126CA01100 Jurisdiction: Tigard Name of Business: Target Business Address: 9009 SW HALL BLVD 100 Applicant/Agent: Brown, Chris Work Description: New signs for Target Permanent: Yes Freestanding: No Freeway: No Temporary: Wall: Yes Electronic: No Billboard: No Balloon: No Banner: No A-Board: No Sign Dimensions: 15x15 Total Sign Area: 225 Wall Area: 9128 Wall Face(Direction): North Sign Height: 27.7 ft. Projection From Wall: 6 in. Illumination: Materials: Acrylic and Alum Electrical Permit Required: Yes Building Permit Required: Yes Total Permit Fee: $605.25 Conditions: This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. A permanent sign must be placed within 90 days from approval date or sign permit shall expire. A temporary sign shall expire 30 days from validity date. A balloon sign shall expire 10 days from validity date. Approved By: ' Y • e I o Permittee Signature: ________. Sign A RECEIVED City of Tigard mi COMMUNITY DEVELOPMENT DEPARTMENT MAR 2 0 2017 „11 : Sign Permit Application CITY OFTIGAPD T I GARD PLANNING/ENGIN 'RING o SIGN LOCATION REQUIRED SUBMITTAL Address: 9009 SW Hall Blvd Suite #: ELEMENTS City/state:Tigard, OR Zip: 97223 /J�2 copies of elevations on 8'/2"x 11" Tenant or business: Target or 11"x 17"pages(Wall sign elevations must include dimensions of sign and wall face and show the Property owner name: T6i QA- Gore• location of sign on the wall. Address: 9 cool Sw Ii-r4 I( €I'd . Freestanding sign elevations must City/state: Zip: be drawn to scale.) Phone: Email: /2 copies of site/plot plan,drawn to scale,on 81/2"x 11"or 11"x 17" pages(not required for wall signs) Sign contractor: Vancouver Sign Group List or diagram of all existing sign Address: 2600 NE Andresen Rd Ste 50 dimensions and square footage City/state: Vancouver, WA Zip: 98661 0 Application Fee Phone: 360-787-8099 Email: (''Rrnwnevanai clnrn_corn CCB License #: ti 1 9 S 1 Expiration date: 1/24/2018 NOTES: • Freestanding signs over 6 ft.in height Contact person: Chris Brown and walls signs of which any element weighs 20 lbs.or more require a building permit for construction. SIGN DATA (Complete all items in this section) If any element of a wall sign weighs 70 lbs.or more,plans must be prepared TYPE (Check all that apply) by a structural engineer. Q New sign 0 Freestanding 0 Electrical • Building permits require 2 sets of 0 Alteration to 0 Freeway ❑■ Wall construction drawings and,if sign is freestanding,2 copies of site/plot plan existing sign 0 Roof 111Other and 2 sets of engineering must be Sign #: submitted with building permit application. Sign dimensions: 15 ' (h) x 15 ' (w) = 225 sq.ft. sign area New sign: 225 sq.ft. + Existing sign area80.25 sq.ft. =305.25 Total FOR STAFF USE ONLY Total sign area: 305 sq.ft./ 9128'47 building face sq.ft.= 3 •3 %of bldg face S 1017 - 0003'L Case No.: Height to top of sign: 27.71 ft. Projection from wall: 6 in. Related Case No(s): Materials: Acrylic and aluminum. Fee: Application accepted: Is the sign under 20 lbs.? ❑ Yes I. No By: 3 Date: 3 /20/ I 1 (Building Permit required if over 20 lbs.) Application determined complete: Direction wall faces (circle one): ® S E W NE NW SE SW in() M / I ii By: ( / Date: �t �A / Will the sign have illumination? U Yes 0 No If yes,what type: I Internal 0 External I:\CURPLN\Masters\Land Use Applications Rev.03/03/2015 City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • www.tigard-or.gov • 503-718-2421 • Page 1 of 2 sor APPLICANTS NOTE: Person specified as "Applicant" shall be designated"Permittee"and shall provide financial assurance for work. *When the owner and the applicant are different people,the applicant must be the purchaser of record or a lessee in possession with written authorization from the owner or an agent of the owner. The owner(s)must sign this application in the space provided on the back of this form or submit a written authorization with this application. THE APPLICANT(S) SHALL CERTIFY THAT: • If the application is granted,the applicant will exercise the rights granted in accordance with the terms and subject to all the conditions and limitations of the approval. • All of the above statements and the statements in the plot plan,attachments,and exhibits transmitted herewith,are true;and the applicants so acknowledge that any permit issued,based on this application,may be revoked if it is found that any such statements are false. • The applicant has read the entire contents of the application,including the policies and criteria,and understands the requirements for approving or denying the application. I hereby acknowledge that I have read this application, that the information given is correct, that I am the owner or authorized agent of the owner,and that plans submitted are in compliance with the City of Tigard. SIGNATURES o each owner of the subject property required. Apç4c7fr ant's signature Print name Date Owner's signature Print name Date Owner's signature Print name Date SIGN PERMIT APPLICATION City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • wwwtigard-or.gov • 503-718-2421 • Page 2 of 2 A 9 I Atiill EXISTING SIGN SCHEDULE N. . .. m - - ,r �N� , A EXIST'G 132" (11'-0") BULLSEYE(Red)LOGO/29" (2'-511)TARGET(Red)LTRS/150.0 SQ. FT. QUANTITY: ONE(1) ON FRONT ELEVATION-TO BE REMOVED&DISCARDED ,� 1+ it . " \ EXISTING 30" (2'-6") CVS pharmacy LETTERS/ 55.66 SQ. FT. Per \ \% k O QUANTITY: ONE (1)FRONT ELEVATION A ...1 �\, # ,.'E ` / D EXISTING 72" (6'-0") BULLSEYE (Red) LOGO/57" (4'-9")TARGET/ 155.78 SQ. FT. Nom_ • & QUANTITY: ONE (1) ON WEST ELEVATION -TO BE REMOVED& DISCARDED • 4. EXISTING 72" (6'-0") BULLSEYE (Red) LOGO/57" (4'-9")TARGET/ 155.78 SQ. FT. NN `1 -1I... /E\ QUANTITY: ONE (1) ON SOUTH ELEVATION -NEW FACES & LED INSERTS -t. {M Previously Permitted TOTAL BLDG. SIGNAGE. 461.56 SQ.FT. JP 1 I< v Ski' Cam k, ICI ../ el 6 .?`T J 0\� o� PROPOSED SIGN SCHEDULE ; 0 $ • . © 180"(15'4")BULLSEYE(WHITE)LOGO/ 225.0 SQ.FT. • ti) !•••••,N'- Ifil QUANTITY: ONE (1) FRONT ELEVATION-NEW . r Z— f ,- e 14" (1'-2") (Red)ORDER PICK UP LETTERS/ 24.59 SQ. FT. I� 6 " ir Q QUANTITY: ONE (1)FRONT ELEVATION- NEW i . . R EXISTING 30" (2'-6")CVS pharmacy LETTERS/ 55.66 SQ. FT. l • O QUANTITY: ONE (1)FRONT ELEVATION- NEW ; 111111 , . 120" {1O' 0") BULLSEYE (RED)LOGO 100.0 SQ. FT. - © QUANTITY: ONE (1) ON WEST ELEVATION - NEW a AI EXISTING 72" (6'-0")BULLSEYE(Red)LOGO/60" (5'-0")TARGET/ 155.78 SO. FT. _. • � QUANTITY: ONE (1) ON SOUTH ELEVATION - NEW FACES & LED INSERT M " PROPOSED TOTAL BLDG. SIGNAGE:563.12 SQ. FT. / - ' • .P . . M • ' r .01. . . _ • $ lIl r ti #r'R - EXISTING GROUND SIGN REPLACEMENT FACES/EXISTING D/F PYLON SIGN RECEI\I I) SITE PLAN - NTS 13 © QUANTITY: TWO (2)FACES REQUIRED A MAR 2 0 2017 D CITY OF TIGARD PLANNING/ENGINEERING OnS III I FEDERAL R2.61316B RI6116VA/CH Rev AIrom1416SCR ARobteaemdCProea;Locauon. This original drawing ManUfaa"d'gF'°II"" R16,9,69wRevAir°m,6rals. Hc:.>un kelt BOYD HIPPENSTEIL 23-37506-10 i O2arUIG[. F.-ELeess,TX-b°GonvEle.Tx-Delaware,OH s provided as part of a HEATH R511 16 1 RN Rev slope iAMS N remove B apiece sr/lD bullsere JobNumber planned project Ra placementSANDRA RAMIREZ 0p A p Rolec'. Manager RS 11 16 16 RMUBlu Per AMS Notes and is not to be exhibited, °�anf°` L "'" L 9""' Z 10810`°'° Date. MAY 19, 2016 copied or reproduced Euless,lx AdcsGnuek.1x•San MlDniD,7Jl-Corpus CTrrlm,TX IFF r,se:- - �r.(whey ale Phur, r,Ietier,aloretl p p SIGN COMPANY oravrl�r ROBERTO MIJARES/JK/JDR Ins,,TX J cksonv le TX• an ion.,7 TN Corpus ulwlee KY without the written Grnrton W1 Willowbrook,IL Tunica,MS Colors D t i led In This Renclenng May Not Matrh Actual finished Matenals Refer To Product Samples Eu'Exact Color Matcr• urldtlwm,if f EaECTecAI TD u u,L LISTED e r m I s S I O n of www.FederalHeath.com �U� nuc GDEEaONCaRANDSUl1MlFf Store Number:T0345 Sheet Number. 1 01 1 p Atlanta,W-Tampa,FL-Daytona&each,Fl�Orbtdo,FL Laboratories tilt. ALL N.E.C. STANDARDS Federal Heath Sign 4602 North Avenue Oceanside,CA 92056 Client ApprovaVDate: 9009 SW HALL BOULEVARD g (760)941.0715 Fax 1760)631-5065 AllICLE •0(Al NG E ARE TOCOMPLYRr1TNU.t as AND 23-37506-10-R6 Company, LLC or its BuildingQualitySignage Sinee 1901 ARTICLE .GC OF THE N.E.C. STANDARDS, INCLUDING TIGARD. OR 97223 Design Number Landlord ApprovaVDate: OPER GROUNDING AND EGNDING OF ALL SIGNS authorized agent 01-HSC • ± 425'-1" • • A IA E_T o1 4 1 t !0 • I wild I ,,. ...i. 1. 11111 Alli lli - . , .........._. T - �, 36e e00i is N •ms ;, • Res - +I 4, .'. '. .:' Gr'' ,.. E I - .. .. : A� MIBgal P41 117 '5. . _. _..:I,n 7!ri-Iii rria„ EXISTING NORTH ELEVATION - STORE FRONT Scale 1/32"=11-011 yr , •L �•' .• • " ` �'� ` L 1 og Nei .1 •.i. • r.- ••' Y ., 'Alt 4"1"'' +{' _ rn „9r t~ • .c i - - _1 . , ... 1 ` •O'''''' 1 • . i r11 REG*- s; s--ill — . . w 14 ..,.,"...I..: . Ft 0 . r EXISTING CONDITION NTS FEDERAL Revisions. R118161M/(HOvAYKmlrrPri'8drplEu.rd[ Project This original drawing Oceanside,CA 9JarlaDnM1e,17(-peiawye,OH IC6.13-16 BW Rey A from l6'to 15' Account Rep'. BOYD HIPPENSTEIL I� provided as part of a ri f0 6.15.111 pra reepe w 0 rP RRRPrE t ryMoR7IC WWI Job Number: 23-37506-10 HEATH R47.06.16VA/CH Rey Sipe AAISNo plowmen! Project Manager SANDRA RAMIREZ ar:a n n e d project once Lacalbm� RS 11 16,16 RA1pN As PorAMS Nines 0 and is not to be exhibited, Oceanside. skgat.NV-LaugNm,AZ Falls, Date. MAY 19, 2016 copied or reproduced Euless,TX-Jaocson,Me,TX-San Antonio,TX-Corpus Okla TX R6 DI 2617 VA/Al Revised plowmen!of Sign C where old Pharmacy leaers plated Drawn By. ROBERTO MIJARES/JK/JDR SIGN COMPANY IntltinapaG,IN-°Naware•OH-'�naeTN-LD"""ne.Kl � without the written Grafton,W•WNowaraa&,R-Tu,Nca,MS Colors DeprctrU In lhrs Render log May Not Ma[ch Actual Finished Materials Rein Tr,ProOuci Samples To;Flacr Color Match �l undwtim 0 SECTRKAL TO DSK U.L.UT= Store Number: 10345 2 Of 11 ;' e r m I s s I o n of w w w.Fe d e r a I H e a th.c o in COeR ONBP6 AND SIWL M! sheet Number. Atlanta,W-Tampa,FL Daytona Beach,FL-ORando.FL Laborutoria inc. ALL N.L.C. STANDARDS Federal Heath Sign 4602 North Avenue Oceanside,CA 92056 Client Approval/Date. 9009 SW HALL BOULEVARD g (7601 941 0715 Fax 17601 631-5065 Signage ALL ELECTRICAL SIGNS ARE TO COMPLY WITH U.L..P AND Company, LLC or its Building Quality 51 na a Since 1901ARTICLE 600 OF THE N.E C. STANDARDS. INCLUDING TIGARD, OR 97223 Design Number. 23-37506-10-R6 9 J g g LandlordApprovaUDate: THE PROPER GROUNDING AND PONDING Or ALL SIGNS aJthonZed agent ©FHSC • 4 12'-31/2" (TARGET) 11'-0"(BULLSEYE) 1'-10"" 1'-10` 3'-8" *41'-10' 1'-1D`� 22'10 5/8"(B) • ♦ 3'-1 1/16"(C) I I 6-81/4"(D) I ` 12'-2 5/8"(E) 0 NpharmacyH.H.... I ,... . .._ EXISTING 30" (2'-6") RED CVS Pharmacy CHANNEL LOGO & LETTERS zcr QTY: ONE (1) Scale: 1/4"=1'-0" SCOPE OF WORK: EXISTING SIGN TYPE TO REMAIN AS IS. NO ACTION. EXISTING LOOK NTS 11l -TARGET "I V V 35'-0" O.A. Per Survey 4 1► EXIST'G 132" (11-0")BULLSEYE(Red) LOGO 6'-0" 27'-10 112"± A 29" (2'-5")TARGET(Red) LTRS/ 150.0 SQ. FT. + # j 1) ONE REQUIRED SCALE: 1/4" = 1'-0" • LOGO = 121.0 S0. FT. 0 TARGET • TARGET = 29.0 SO. FT. = TOTAL = 150.0 SQ.FT. C • o Er) C) SCOPE OF WORK: REMOVE AND DISCARD EXISTING AND REPLACE WITH NEW SIGN. V 204 SQ FT EXISTING 72" (6'-0") BULLSEYE (Red) LOGO/60" (5'-O") TARGET LETTERS D ! \ Scale:3/16"=1'-0" LOGO = 36.0 SQ.FT. LETTERS = 146.5 SQ. FT. OVERALL TOTAL= 204.0 SQ. FT. EACH D SCOPE OF WORK: EXISTING SIGN TYPE TO BE REMOVED AND DISPOSED. /E\ SCOPE OF WORK: EXISTING SIGN TYPE TO BE REFACED l NEW LED INSERTS 11 FEDERAL " Rb U16YA[OlryrAlrow14Is16'&dropianmemsIC. Project/Location: This original drawing AraxraLDRrrgFedtdea: AccourrcRep BOYD HIPPENSTEIL 23-37506-10 isprovided as part of a oTearwDT,a EIMss,Tx-laDeornnBe.rx-DeDRvre,on R'1613.16 BW Rev A from 16'to 15'. H EAT H 6.15.16 BW Rev xope kir D ro amore 6 reploQ w/11r 6ulbge Job Number orllrr tDraao,D' R4 7.06.16 Rev S ALDpleamwr. Rep- Project Manager. SANDRA RAMIREZ planned project RSn.tdt6RMil(AsPaAMSNo1w and is not to be exhibited, OavruMe.U.Las /VV-Laughlin.a-Idaho Facts,ID MAY 19 2016 Eros,rx-latloorlrare.TX-San Antonio.TX Corpus anise,TX R6 01 26 17 VAUR Revised plaremem of Sign C where old Pharmacy letters placed0 Date: I copied or reproduced Indianapolis,"-Delaware.°"-Ir waw a rN•�akv ae.RT Drawn By. ROBERTO MIJARES/JK/JDR without the written SIGN COMPANY R a Grafton,WI-04 rowDrooi A-Tunica,MS Colors Depleted In ThiS Rendering May Not March Actual Finished Materials Refer 7o Product Samples For Exact Color Match fleCTIBCAL TO use ui LISTED Store Number:T0345 3 Of 11 p e 7 m I S S I O Il of www.FederalHeath.comU� unde^ � ne mwORlleaanANosSwacaratT Sheet Number: manta,GA•Tampe.FL-DaytonaBeach,Ft R LaboratoArinc. , ALL N.E.C. STANDARDS Federal Heath Sign 4602 North Avenue Oceanside,CA 92056 ClientApproval/Date: 9009 SW HALL BOULEVARD 9 17601 941-0715 Fax(760)631-5065 ALL ELECTRICAL SIGNS ARE TO COMPLY WITH D,L...AND 23-37506-10-R6 Company, LLC or its BuildingQuality sl ria a Since t got App A.TIELE aaa OF THE N.E.C. STANDARDS, INCLUDING TIGARD, OR 97223 Design Number g gLandlord roval/Date: THE ARO4ER OROUNDIND AND BONDING Or ALL SIGNS. authorized agent ®FI'OSC *.. 1 .x --...:=': ± 424'_7 1 _t' . xi�x.'�.'.�: r'r�.- - �ti�" .._ _ SSa�-r -. _ .. ''-� • 94'-0" •° 13'-0"r , 1 t NEW ,4,, ISIGN TYPEI „ ' -- i` �12'-6" 15'-0" NEW I 4 4' f SIGN TYPE t I 072'-10" —5'-1O I O I t 1 T§ I 'yl I j.„, I 86 to if c� • I I T N— _ I N+ IIIIIIINL5141 td CV 1111* I 12'-8h Il =�ailra1501r " PROPOSED NORTH ELEVATION SEE ENLARGEMENT DETAILS SEE ENLARGEMENT DETAILS EXT PAGE NEXT PAGE Scale 1/32'=1'-0" ± 313'-2' t 1"Ilimillirilll' ' : Ia NEW vnE D 4'-10"--110'- 0" y t1 io f 0 10'-0" i • o N T 'T .,, at +1 ® s S 1 I ~ N +, .......... . , ., , PROPOSED WEST ELEVATION Scale 1/32"=1'-0" ± 424'-7" 1 i ± 34'-0" tlis. , 4 ---- f I -annff t ev G 6'-p' 1-O e N !I . 1� .., pt Std LA. - t� PROPOSED SOUTH ELEVATION Scale 1/32"=1'-0" /Mk . ,. w z,.. i 1 FEDERAL Marxrracanny rauanes. R16.8.16 VA/CH Rev A tram 14'10 16'K th placement olCPro /LocationThis original drawing R26.13.168WRerAlrom161oi5' 9PAccount Rep. BOYD HIPPENSTEIL � 23-37506-10 a provided as part of a oLTvrDioe,u-EuNss.nc-Jaasormlle.IX Delaware.OH 113 6.15,16 BW Rev nope kr 0 l remove Breplace sr/10 6ullseye O Jot'NIJrphc'r HEATHSANDRARAMIREZ alarmed project Office Inurrons: R4 7.06.16 BW R.Rev Sign A 8 0 placemen Project Manager: and is not to be exhibited. R51116.16RMUKAsPerAMSNotes MAY 19. 2016 Omar&Ca Las Vegas,NV Laughlin, •IddhoFarts,ID Datc. copied or reproduced Euless.Tx AaDoonme Tx•sari AntAn TX-Corpus cnruo Tx R6 01.26.17 64/1K Revised placement of Sign C when old Ph., -,placed Drawn By ROBERTO MIJARES/JK/JDR SIGN COMPANY '""""'pail'" °ia"aroOH xr I' TN Loursvle " without the written Graft n,Wr wnD.w oar n-hence MS Coors Dep:ctea Ir Tho Renaenn5 May No:Match Aco, rimshed Materials Wet 10 Pooh hot,ro,6OaCI Colo:Mat Underwriters BEC7IRCH 70 USE ui.Law Store Number:T0345 11 h e f RI I S 5 I O h O r www.FederalHeath.com ;7-- Grafton ;11�� ncl ANDs,«t�R,eE. Sheet 4 0l 4602NortnAvenue Oceanside,CA 92056 Marna.a.GA Tempe FL•Daytona Beach,F onanao.ti Client Approval/Date: "�Lah"nlDNaal^� ALL N.E.G. STANDARDS 9009 SW HALL BOULEVARD Federal Heath Sign ALL IC AL SIGNS Atte To CO"PLY WITH U.L.•E AND Company, LLC or its (7601 941-0715 Fax(7601 631-5065 BuildingQuality Signage Since 1907 I andlord ARTICLE EGO OF THE N.E.0 ST S, INCLUDING TIGARD, OR 97223 Design Number 23-37506-1 0-R6 F 7 Approval/Date: THE PROPER GROUNDING AND RONDING OF ALL amniaaut,ionZed agent C1-HSC 94'-0 13'-0" NEW 4 SIGN TYPE t NEW i . 12I-6",f, 15 -0 IP SIGN TYPE 0.... , 1 D 1 12'-10" ,--1 5'-10" .... .f-- t , .. , , 4,-t, . Imimilit . —"15' 0" , 0 .. N -11'-111 _a_ _ order pikktup _ as mi . ' ... A . - . . ■ �— r "II 1111• • a-r; 1 1 1 r; a ►as111111 ,1 +1 ENLARGEMENT DETAILS - PARTIAL NORTH ELEVATION 1 SCALE: 1/16"=1'-0" +�'� NEW 4'-10" — 10'-0" U SIGN TYPE 22'-3 5/8" Ell '0 s I I —, �' , I 0 10'-0" 5'-6" 2'-6" CSphaacy +I - i/ ±11 -5 4 ENLARGEMENT DETAILS - PARTIAL NORTH ELEVATION 2 ENLARGEMENT DETAILS - PARTIAL WEST ELEVATION SCALE: 1/16"=1'-0" SCALE: 1/16"=11-0" Revisions lhls original drawing Manuraml Fatrtra. R2 6B.1 Y CN Ra A from 14'to I b'8th placement of C Project/Location: g g II �E DE RAL u °p Account Rep BOYO HIPPENSTEIL23-37506-10 oQansrae,G-Ewes.Tx-Txfsondur,IX-Detsware.off 613.16 BW Rev A 1mm 16'to IS' Is provided as part of a R3 6 15 16 BW Rev scope for D to remove&[opiate rrt it'bullseye. O got,Number: planned project HEATH omtc Locations R41 D6.16 P1101 Rev Spy A A D ploteneetel Project Manager SANDRA RAMI R EZ and is not to be exhibited, RS 11 16.16 RNA As Per AMS Nares MAY 19, 2016 °�dn°"' `9a "^ "^� i°'"°F" 'o Dare copied or reproduced Ewes&TX-Jit: the rx-sa<antonio,TX-Corpus Crimp ix era 2( I As. edplacementoiSipCwhereoldPharmacyleTelsplaced Drawn By ROBERTO MIJARES/JK/JDR without the written SIGN COMPANY IndianapoRt,IN•Delaware,OH-Knoxville TN-Lewisville.KY Grafton.ua�Willowbrook,IL-Tunica,MS Colors Depleted In This Rendering May Not Match Actual Finished Materials Refer 70 Product Samples For Rear':Cob:Mal.' ®fin {. ...entKwL To use u--memo Store Number:T0345 5 m 11 permission of www.Federailieath.com " e` caRtPDNeAtrsANosvNtL MST Sheet Number. Atlanta,GA Tanlpa.FL-DaytonaBeadl,fl-Orlando.Fl App taAon6erhnlne.�; ALL N.E.C. 57ANDAROs 9009 SW HALL BOULEVARD Federal Heath Sign 4602 North Avenue Oceanside,CA 92056 Client rovaVDate: 17601941-0715 Fax(7601631-5065 """"'"""11GN5^""°`°""""""°` """° 23-37506-10-R6 Company, LLC or its BuildingQuail Signage Since 1901ARTICLE 600 OF THE N.E C STANDARDS, INCLUDING TIGARD, OR 97223 De LUT Number. tYLandlordApprovaVDate: THE PROPER OROVNDIN4 AND aONDrNG ALL TION, authori2ed agent. ©FHSC [ JON-STANDARD IMATERIAL FINISH COLORS OVERALL SIZE WHITE ATUGLASI7328 � WHITE Sklar Wnlle Acrylic LED Returns Fuss Relainer/Trim-Cap Illumination '— C —•" — D —Il';.— E 1" F ►. G --* 611 SPACE MAXIMUM 1" f SPACE MAXIMUM 1" rMINIMUM 1/2" MINIMUM 1/2 6" I WALL ll • • •• i — ti .r. OBO ALUMINUM FILLER INTERIOR PAINTED:WHITE {• - P e .i` BUSTING r. '''.'.' 4 .063 ALUMINUM RETAINER ELECTRICAL ' ' �_ n ,r ` PANEL Its c • \\\` MINIMUM.090 ALUMINUM BACK f f f11 p PIGMENTED ACRYLIC FACES I lass i SLOAN LED ' _ 'asr Las A 2 ELECTRICAL BEYOND SIGN �' � LOCK-ABLE DISCONNECT 0. BY INSTALLER ; SWITCH BY OWNER-WIRED 4%1 ' INSTALLER TO PROPERLY SEAL WALL j — BY ELECTRICIAN — �IIV SEALER:BASF-Master$eal NP 150 (1 PER CIRCUIT) iiiTte '\` \ -- ALL MOUNTING HARDWARE(INCLUDING SPACERS) '■ J-BOX BY INSTALLER �p{ >, TO BE SUPPLIED BY:INSTALLER k� POWER DISTAIBUAON BOARD \ MINIMUM 3;6"STAINLESS STEEL MOUNTING HARDWARE I _. ; BY FEDERAL HEATH _. ‘1111 24 V CLASS TWO POWER - \ -----••'''''''' • B SIMPLY,SUPPLIED BY (2)-WEEP HOLES PER LOW SPOT I FEDERAL HEATH :.. - - MOUNTED BY SUB-CONTRACTOR \ L- ~CLASS 2 SECONDARIES TO DISTRIBUTION BOARDF. I , ' TO BE RUN THROUGH CONDUIT SUPPLIED BY `',/iR"nu"owonnroIBuuEiimil d11111111111111111111111111111111111111111,' ,4'" INSTALLER AND WIRED BY INSTALLER. ♦ --- I. .. "``- DISTRIBUTION BOARD AND POWER SUPPLIES SUPPLIED BY FEDERAL HEATH SIGN CO. LOGO/WALL DETAIL NOT TO SCALE END VIEW 1 • (Generic) © ACRYLIC FACED INTERNALLY ILLUMINATED "BULLSEYE" CUSTOMER TO PROVIDE NEW t REMODEL CONSTRUCTION DEDICATED BRANCH CIRCUITS FOR ADEQUATE BEHIND THE WALL BACKING AND SIGNS ONLY PER NEC CODE 6003 ACCESS IS REQUIRED FOR THE INSTALLATION ALL BRANCH CIRCUITS SHALL!N DEDICATED TO OF NEW SIGNAGE. CUSTOMER TO FORWARD SIGNS(INCLUDING GROUND ANT NEUTRAL)AND APPROVED SIGNAGE DRAWINGS TO THE ON SHALL NOT BE SHARED WITH OTHER LOADS SITE CONTACT TO INSURE THAT THE REQUIRED MANUFACTURE AND INSTALL CHANNEL LOGO AS SHOWN AND NOTED ELECTRICAL REQUIREMENTS PROPERLY SIZED GROUND WIRE THAT CAN BE PROVISIONS ARE MADE DURINGCONSTRUCTION, TRACED BACK TO BREAKER PANEL IS REQUIRED. PRIOR TO THE SIGN INSTALLATION. V3—`). � Total:0.0 Amps INSTALLER REQUIREMENTS NESTALLER REQUIREMENTS FOR EIFS WALLS SIGN TYPE A B C D E F G RETAINER SCI.FT. QTY ` ALL MOUNTING HARDWARE, SECONDARY ITIS THE RESPONSre111TY1WTHE INSTALLATION Weight: lbs WIRING AND CONDUITS ARE TO BE PROVIDED CONTRACTOR TO PROVIDE ANY WALL SPACERS 180 BULLSEYE-W 15'-0R 15'-I)° 2'-6R 2'-6" 5'-0" 21-6" 2'-6" 2" 225.0 I BY THE INSTALLATION CONTRACTOR. REQUIRED TO KEFPFIFS WALL MATERIAL FROM 1 ) 1 20V 2OA Circuit Required. ALL PENETRATIONS IN THE WALL ARE TO BE BEING COMPACTED DURING INSTALLATION OF SEALED WITH SILICONE AND TO BE WATERTIGHT. ANY MOUNTING BOLTS REQUIRED FOR SIGNAGE. ALL BRANCH CIRCUITS SHALL BE ANY DEVIATION FROM FEDERAL. HEATH DEDICATED TO SIGNS(INCLUDINGGENERAL NOTE GROUND AND NEUTRAL)AND SHALL REQUIREMENTS MAY RESULT IN DAMAGE •INSTALLER SHILL PERMWALL CONDITION IN THE FIELD NOT BE SHARED WITH OTHER LOADS. TO OR IMPROPER OPERATION OF SIGNAGE, -TYPE,SIIIAND MAZER OFFASTEHERS TO RE DETERMINED. CAUSING DELAYS AND ADDITIONAL COSTS. • ALL DOLT HOLES TO IE DRILLED DA PUNCHED •ISOLATE ALL ALUMINUM FROM STEEL 4NSIMMINTAINIMMIIINTEMIFill FEDERAL RevisionsIMie: _r: . R}6.R.I6YAlCMi ileto116'AetgplRamrud( Account RepBOYD HIPPENSTEIL This ori lnal drawing naa Nnam,Ry Fadwuea. R2613.161411.Mimi 16'to 15' Project/LocatIon 23-37506-10 is provided as part of a oaearGae.u-tWess,TX-�anLsoAvnk,TX-Crammer,OH R3 6.15.16 BW ser,cope bib b remRT.r b wipe le IP baHNTE Job Number. HEATH R41A6.16RAVA/CH As EDpbnmwr Project q SANDRA RAMIREZ planned project oceannee gas, Locations'Laug RS 11.16.16 RANK k hr AMS Nan manager0 and is not to be exhibited, Vegas.w-La gNin.K-Idaho Falls.!D e11aS.Tx-SaoDonwrc.Tx-San MmNo.ix-corpus coronas DL R6 Ol 2611 VA/11(Revised placement of Sian(share alb Pharmory letters plated Dare: MAY 19, 201 6 copied or reproduced Drawn B, ROBERTO MIJARES/JK(JDR without the written SIGN COMPANY less.Indianapolis,W-° es ao -RAaMee TM � .KY i Grafton,1N WewsnpooA,R Tunica My Colors Depicted In This Rendering May Not Match Ac[ua!Finished Materials. Refer To Product Samples Fa Exact Color Marc f El�C7AEK o L16E ua.LLfTm Store Number:70345 6 Q( I 1 permission www.Federalkeath.com AGanb Ta r;•D 'U Ond.nr"" n e co YMCAL T ANouwLAesr Sheet Number. o f 46oz IVorllSwvenue Oceanside,CA 92056 p'' ""°�'�"°'" °"in0o'" ClientApprovaVDate: ��Laboratories WIC F ALL N.E.C. STANDARDS Federal Heath Sign 9009 SW HALL BOULEVARD Company, LLC or its (760)941-0715 Fax(760)631-5065 ALL ELECTRICAL SIGNS ARE TO COMPLY WITH U L RID AND 23-37506-10-R6 Building dual Signage slnee 1901 ARTICLE SI 00 OF TOE N.E C. STANDARDS, INCLUDING TIGARD, OR 97223 Design Number. 9 nyLandlord ApprovaVDate: TN.PROPER GROUNDING AND PONDING OF ALL SIGN. authorized agent. ®FHSC • • SPACE MAXIMUM 1" R • B • 5" I WALL MINIMUM 1/2" 1 040 ALUMINUM FILLER I' �. .1-T p PRE-FINISHED ALUMINUM 1 w j H EXISTING �, C 1"TRIM CAP ELECTRICAL fij A PANEL MINIMUM.063 ALUMINUM BACK _. I �. 1 BN I 1 r PIGMENTED ACRYLIC FACES �i lil GE LED ' ACRYLIC FACED INTERNALLY ILLUMINATED CHANNEL LETTERS L•"ELECTRICAL BEYOND SIGN -1- lin I� LOCK-ABLE DISCONNECT (t". 0 BY INSTALLER SWITCH BY OWNER-WIREC I jr INSTALLER TO PROPERLY SEAL WALL I — BY ELECTRICIAN. A+. SEALER:BASF-MasterSeal NP 150 1 . 1. , (1 PER CIRCUIT) MANUFACTURE AND INSTALL CHANNEL LETTERS AS SHOWN AND NOTED I d-BOX BY INSTALLER "' ALL MOUNTING HARDWARE(INCLUDING SPACERS) TO BE SUPPLIED BY INSTALLER it' - } POWER DISTRIBUTI(1N BOARD • IBY 511 MINIMUM 3/B'STAINLESS STEEL MOUNTING HARDWARE i <! ----� to FEDERAL HEATH ......2I v7 i ;R .0. — 24 V CLASS TWO POWER SIGN TYPE A B t C SQ.FT. QTY c SUPPLY SUPPLIED BY Weight: 11lbs or 1 WEEP HOLES PER LOW SPOT FEDERAL HEATH 1• OPU14-REMOTE-R 1'-2" 12'-10" l'-11" 24.39 1 — — ____ _. • , = MOUNTED BY SUB-CONTRACTOR _ I b per element. 14 I CLASS 2 SECONDARIES TO DISTRIBUTION BOARD - s TO BE RUN THROUGH CONDUIT SUPPLIED BY ' -'%rrni nuttunumuuumuurorau tuuumumrununumrunwmNrla r'• I INSTALLER AND WIRED BY INSTALLER. MATERIAL FINISH COLORS DISTRIBUTION BOARD AND POWER SUPPLIES SUPPLIED BY FEDERAL HEATH SIGN CO. LOGO/LETTER WALL DETAIL NOT TO SCALE 1111MP*82074LVG 2793 LD Red °' I (FULL GLOSS) ■Modified Acrylic IIIRed ■Sloan RedII'-.'0.1 • (Generic) (AHuglas or Equiv.) LED 4.1K-3' Returns Fares Trimcap/Relainer Illuminalion d• ,44 A. I CUSTOMER TO PROVIDE NEW&REMODEL CONSTRUCTION ' DEDICATED BRANCH CIRCUITS FOR ADEQUATE BEHIND THE WALL BACKING AND NOTE: SIGNS ONLY PER NEC CODE 6003 ACCESS IS REQUIRED FOR THE INSTALLATION • WALL IS TILT UP CONCRETE AND THE WALL COLOR IS SW 6121. + arii All BRANCH CIRCUTTSSHALL BEDEDICATED TO OF NEW SIGNAGE. CUSTOMER TO FORWARD SIGNS(INCLUDING GROUND AND NEUTRAL)AND APPROVED SIGNAGE DRAWINGS TO THE ON • • ELECTRICAL CIRCUIT REQUIREDNTACT TO INSURE THAT THE REQUIRED . SHALL END VIEW ELECTRICAL REQUIREMENTS PROPERLY SIZEDBE SGROUND HARED RETH T CA PROVIADS SITE SIONS ARE MADE DURNGCONSTRUCTON, TRACED BACK TO BREAKER PANEL IS REQUIRED PRIOR TO THE SIGN INSTALLATION. Total: 0.0 Amps INAALLER REQUIREMENTS INSTALLER REQUIREMENTS FOR EIFS WALLS ALL MOUNTING HARDWARE, SECONDARY , IT IS THE RESPONSIBILITY OF THE INSTALLATION WIRING AND CONDUITS ARE Ti)BE PROVIDED 1 CONTRACTOR TO PROVIDE ANY WALL SPACERS BY THE INSTALLATION CONTRACTOR. REQUIRED TO KEEP EIFS WALL MATERIAL FROM 1 ) 1 20V 20A Circuit Required. AU PENETRATIONS IN THE WALL ARE TO BE ' BEING COMPACTED DURING INSTALLATION OF SEALED WITH SILICONE AND TO BE WATERTIGHT , ANY MOUNTING BOLTS REQUIRED FOR SIGNAGE ALL BRANCH CIRCUITS SHALL BE ----__.___ DEDICATED TO SIGNS(INCLUDING ANY DEVIATION FROM FEDERAL HEATH _ MINERAL NOIR GROUND AND NEUTRAL)AND SHALL REQUIREMENTS MAY RESULT IN DAMAGE •INSTALLER SHALL VERIFYWALL CONDITION IN THE FIELD TO OR IMPROPER OPERATION OF SIGNAGE, •ME,SItE AND NUMBER OF FASTENERS TO BE DE1ERMIHED. NOT BE SHARED WITH OTHER LOADS. CAUSING DELAYS AND ADDITIONAL COSTS. •ALL BOLT ROLES TO BE DRILLED OR PUNCHED •ISOLATE ALL ALUMINUM FROM STEEL 1 ri FEDERAL Manufacturing Facilites R16116VA/CNRey Almm14'rol6'Rrh IacementaiC. Project/Location. This original drawing O¢asIck.CA•Euless,T%-AuaaMNe,rx-Delaware.OH R26 13.16 BW Rey A from I6 m 15'. Ra Account Rep: BOYO HIPPENSTEIL L� P vl0 23-37506-10 provided aspart of a HEATH L9 6.15.16 DW Rei Pope b D remove.t I RAwc ie h•illye Job Number:84706.16 VA/CNRer Si9,ABDploameM. Project Manager SANDRA RAMIREZ planned project a l 1.16.16 AM/1K k Per AMS Now and is not to be exhibited, oceanic&Ca-Las Vegas.NV-""9Na,.AZ-Idaho FNA,p Date: MAY 19, 2016 copied or reproduced Euless.Tx-ladaonyWe,Tx-San Ar•rnuo.T%-corpus Christi,DI R6 012617 VA/d0 Revised*omen!of Sign(where old Pharmacy lenen pitied P P Drawn By 8061870 MIJARES/JK/JOR Indianapolis, TN-coulswle.m without the written SIGN COMPANY Grafton,w-wtowoma.IL-Tunica.MS Colors Depicted In This Rendering May Not Match Actual Finished Materials Refer To Product Samples For 6xaci Color Matcr. SAL 1D use 1Al u� of www.Federa,Heath corn UL Ikld•rWnw. ® oaftrne..FSANosHftu.war Store Number: 70345 Sheet Number: 7 Of 11 permission 4602 North Avenue oceanside,GA 92056 MAAG G"-T'm°a'�-Dajicn"A.1'Fe o"A"." ClientApprovaVDate: •• ALL r•■•C. ST s Federal Heath Sign (760)941-0715 Fax x760(631-5065 ALL ELECTRICAL SIGNS A•E TO COMPLY WITH Y.L.••AND 9009 SW HALL BOULEVARD Company, LLC or its Building Quality Signage Since 1901 ARTrcLe Eaa or THE N.E.C. ST . INCL•OIN• TIGARD, OR 97223 De Number: 23-37506-10-R6 9 7 Landlord ApprovaVDate: rH.PRO,.orouNDING woo•OMOIMO OR ALL 1100// authorized agent ®FHSC • MATERIAL FINISH COLORS B I. MP#82074LVG 2793 LO Red ■ (FULL GLOSS) ■����AcTYIK a Foot} II . ba Red LSn RM Returns Faces TrbecalttRSWlnr IIYxaliMlen 4— C ---o 0 —1+--- E ►r F —104— G •► SPACE MAXIMUM 1" • 6°1 SPACE MAXIMUM 1" MINIMUM 1/2" MINIMUM YzD ` 6 �WALL� I► t.,} i . . . I .080 ALUMINUM FILLER ,-, INTERIOR PAINTED:WHITE 4 i .063 ALUMINUM RETAINER 4. , E�ELECTRICAL I* :1 I1 _ PANEL — i Fi. .« MINIMUM.090 ALUMINUM BACK , � E3 I PIGMENTED ACRYLIC FACES _, ;� SLOAN LED TO BE SUPPLIED BY:INSTALLER ;. !dV sr A s` /z"ELECTRICAL BEYOND SIGN LOCK-ABLE DISCONNECT er' BY INSTALLER. SWITCH BY OWNER-WIRED 44%,, r'! INSTALLER TO PROPERLY SEAL WALL. !" BY ELECTRICIAN • 4 art SEALER:BASF-MasterSeal NP 150 l (1 PER CIRCUIT) Irl ALL MOUNTING HARDWARE(INCLUDING SPACERS) s BOx BY INSTALLER ( i ' A I y MINIMUM 3/8"STAINLESS STEEL MOUNTING HARDWARE L, POWER DISTRIBUTION BOARD — Ir ; , BY•FEDERAL HEATH _.2.....I ,S. ;I 24 V CLASS TWO POWER -.-__ I t (2)-WEEP HOLES PER LOW SPOT 1, I = SUPPLY,SUPPLIED BY, FEDERAL HEATH - iflb. = MOUNTED BY: SUBCONTRACTOR - - --_ — • CLASS 2 SECONDARIES TO DISTRIBUTION BOARD 4. TO BE RUN THROUGH CONDUIT SUPPLIED BY `<a,11111111111111111111111111111k111111, .1111111111111111101111,11,1,..1,11.• INSTALLER AND WIRED BY INSTALLER. DISTRIBUTION BOARD AM)POWER SUPPLIES'' SUPPLIED BY FEDERAL HEATH SIGN CO. . LOGO/WALL DETAIL NOT TO SCALE END VIEW (Generic) CUSTOMER TO PROVIDE NEW IC REMODEL CONSTRUCTION ® ACRYLIC FACED INTERNALLY ILLUMINATED "BULLSEYE" DEDICATED BRANCH CIRCUITS FOR 51016 ONLY PER NEC CODE TNS ADEQUATE BEHIND THE WALL BACKING AND ACCESS IS REQUIRED FOR THE INSTALLATION ALL IRANCH CIRCUITS SHALL BE DEDICATED TO OF NEW SIGNAGE. CUSTOMER TO FORWARD Weight: 125Ibs SIGNS(INCWOING GROUND AND NEUITIAL)AND APPROVED SIGNAGE DRAWINGS TO THE ON SHALL NOT M SHARED WITH OTHER LOADS. SRI CONTACT TO INSURE THAT THE REQUIRED MANUFACTURE AND INSTALL CHANNEL LOGO AS SHOWN AND NOTED ELECTRICAL REQUIREMENTS PROPERLY SIZED GROUND WIRE THAT COM BE PROVISIONS ARE MADE DURING CONSTRUCTION, TRACED BACK TOBREMERPAWL ISREQUIRED. PRIOR TO THE SIGN INSTALLATION. Total: 0.0 Amps INSTALLER REQUIREMENTS NISTALLE REQUIREMENTS FOR EIFS WALLS NOTE. ALL MOUNTING HARDWARE, SECONDARY IT IS THE RESPONSIBILITY OF THE INSTALLATION SIGN TYPE A B C D E F G RETAINER SQ.FT. QTY WIRING AND CONDUITS ARE TO BE PROVIDEDCONTRACTOR TO PROVIDE ANY WALL SPACERS • BLOCK WALL BY THE INSTALLATION CONTRACTOR. REQUIRED TO KEEP(IFS WALL MATERIAL FROM 120 BULLSEYE-R 1 10'-0" '; 10'41" ' 1'48" 1'-8" 3'4" 1= 1" 100.0 1 (1 ) 120V 20A Circuit Required. ALL PENETRATIONS NI THE WALL ARE TDM BEING COMPACTED DURING INSTALLATION OF • 277 VOLT ELECTRICAL SEALEDWITFISILICONEANDTOBEWATERIIGHT ANYMOUNTINGBOLTSREQUIREDFORSIGNAGE. — — " ALL BRANCH CIRCUITS SHALL BE DEDICATED TO SIGNS(INCLUDING ANY DEVIATION FROM FEDERAL HEATH SENNA NOTE GROUND AND NEUTRAL)AND SHALL REQUIREMENTS MAY RESULT IN DAMAGE •INSEAM SHAD.NEWT WALL CONtNT1ON IN THE FIELD. NOT BE SHARED WITH OTHER LOADS. TO OR IMPROPER OPERATION OF SIGNAGE, •ML NU AND TS N"MOW OR CAUSING DELAYS AND ADDITIONAL COSTS. • •ISOLATE ALL ALYYIAVA FROM STEEL ReviFi FEDERAL : . R16.e.lEVA/(NRevAlrrxnl4'IP16'8thaddromenldlC Account BOYO HIPPENSTEIL �°ea/Locauon: This original drawing NtaMfsaurmg FEL1BceL: ) �] G Oaranside,U-Euless,Tx-HODOrIvNe,7x-DtYaware Ori RY ii.13.168W Rev Alydm l6'Io 15' Z3'37506'1O is provided as part of a HEATH R3S15.16BW Rev scope forDiB remove 8npluew/ID bullsrye JDb Number: planned prrjeCt e locate, R4106.16 YA101 Rev Sign A6Dplacement Project Manager: SANDRA RAMIREZ 8511 1616 RWAt k Per AMS Novel and is not to be exhibited, Ooeanslde.Ca-Las Vegas,NV-Laughlin,AZ-Idaho Faits,1D MAY 19,2016 aims,Dr•ladcsornille,Tx•San Meonlo.Tx-C0 Date: without led Dr reproduced mouscnrtse,Tx R6 OI VAUft Revised Dmiemem al Sign Cwhere old Pharmacy lenen plated Drawn By. ROBERTO MIJARES/JK/JDR Wltph OUt thepwrit ten SIGN COMPANY Indianapolis.w-Delaware,off-Knoxville TN-IDWDARe,RT Grafton,WI-LWYlowbrDOk,IL"Fontes,MS Colors Depict ea In Tres Renoenng May Nor Match ACtual Finished Materials Refer To ProduLt Samples For Exact Color Match ®DIIdef iti Cop To use ut LATID Store Number: T0345 8 Of 11 permission of www.FederalHeath.com Sheet Number: Adana.W•Tampa,FL-Daytona BeaCA,FL-Orlando.FL 1. oralortee Inc. COeN'ONND SISUL MHT 4602 North Avenue Oceanside,CA 92056 Client/ILpprovaVDate: AUL N.S.C.e.C. BT s Federal Heath Sign 1760)941-0715 Fax 17601 631-5065 ALL ELECTRICAL SIGNS ARE TO COMPLY WITH U.L.RJ AND 9009 SW HALL BOULEVARD r� r� Company, LLC °r ars BuildingQuality Signage Since 1901 Approval/Date: ARTICLE tde DP THE N.E.C. STANDARDS. INCLUDING TIGARD, OR 97223 Design Number: 23-37506-1 0-R6 J Landlord THE PROPER GROUNDING AND BONDING OF ALL SIGN,. authorized agent ®i-HSC • E B -F- D - GIN I J — K - 'L,.. , . XM '�,.:,:.. MINIMUMSPACEMAX2I" UM 1" 50 B'�y: A C A R G IE 11.II r.7 .: x ti, 0,_ • • •„fie i.,,,•?,?-.;., Ai , REFURBISH EXISTING LETTER SET END VIEW SCOPE OF WORK: MANUFACTURE AND INSTALL NEW ACRYLIC FACES AND LED INSERTS MATERIAL FINISH COLORS SIGN TYPE A B C D E F G H I J K RETAINER AMPS SOFT. E MP*82074LVG ■27931DRed ■ ■sba �C LED logo letleis CIRCUITS otters (FULL GLOSS) ModifiedAcry6c Rea Slo r w ' • L • T L L R r ■ �1„_ (Ahuglds or EOurv.) LL72/60H-R 6'4” b'0 5'-0" 21'-4 34'4 81/4 1-OR 1-OR 2-01-0 1'-0" 1"RET! B.Oa!1 sir. Returns Fags TrimcapiRetainer Illumination NOTE: i • RUBBING REQUIRED NOTE: • CONCRETE WALL • 277 VOLT ELECTRICAL FEDERAL Revisions: This original drawing ManlbmRmg Fadpon RI 6.6.161/14/01 Rev A lmm la m la 8 dig plinamem of( Account Rep BOYD HI PPENSTEI L Project/Location:rill s odea as part of a o�Tw0e,LA�Euless,ix-Jaoe oro*e.Tx�Detaware,OH 0 6.13.16 6W Rei A from 16'leo 15' pr HEATH g16 S 6B Re uopf o D emomBnpEter 10 builerf 0 JobN�mber 23-37506-10 047.0616 VA/(N Rev SignaBDolotemenl SANDRA RAMIREZ planned project Office RS 11 1616 RM/JR As Per AMS Nolen Project Manager. and 6 not to be exhibited. Oceanside.ea- ,N.-�o9nnn,Az-Itlaho Falls,ID MAY 19, 2016 Date copied or reproduced E„. Tx .ado or-San Aroma°Tx-ca, Christi or 06012617YApORevised placement olSign twhere old p6u,maryleaersplaced Drawn By ROBERTO MIJARES/'JK/JDR SIGN COMPANY Induna,oah,IN-°"e are,OH-,tnown*TN•toao0I,KT without the written Galion.WI-Wlnoworooa,o Tome,MS Colors Depicted In TMs Rendering May Not Match Actual Finished Materials Refer To Product Samples For Exact Color Match %` eaECTwrcx To uu uc c cm Store Number: T0345 9 O1 11 permission of www.FederalHeath.com (�underwriters n coewoR N.E.C. Y 005 Sheet Number: 4602 North Avenue Oreanslde,CA 92056 Atlanta,w Tampa,F-Daytona seam.F -[Mane,F Client ApprovaVDate: Vs L'°°r.wN.'Inc. ALL NE.0STANDARDS 9009 SW HALL BOULEVARD Federal Heath Sign (7601 941 0715 Fax(760)631-5065 ALL ELECTRICAL SIGNS ARE TO COMPLY fRITN.L All Company, LLC or its Building ouau Signage Slnee 1901 ypp V A„TrcLE .ne Of THE N.E.C. siAMOARpS r e No TIGARD, OR 97223 Design Number. 23-37506-10-R6 J tyLandlord .ova Date: a IRoreR 0.0.00.„0 Wt.EONorNC.Of ALL SIGNS authorized agent ®FHSC