Loading...
Report (7) �/ ca / 7- a 3 ii c 54) `i/s 1`,r Product Data Sheet EverGuard®® O Title anJf`¢SCmplt60 mil Membrane 17«fi.. Description GAF EverGuard®TPO 60 mil thermoplastic polyolefin single-ply membrane systems have been engineered to provide superior long-term performance and enhanced durability.Strong,flexible EverGuard TPO 60 mil L.. f.„ membrane is suitable for use in all types of single-ply systems:Mechanically Attached,Fully Adhered, xt 1,,, �::`i-. and Ballast Applied Compared to other heavy-duty single-ply EPDM,PVC and WO membranes,GAF EverGuard TPO 60 mil c'3 1 el 201/ roofing membrane provides the benefits of all three materials in a single membrane:low installed cost,heat welded seams,white reflective color,and no liquid plasticizers. .( }1 ,:-. Applicable Standards UL approved for use in the construction of Class A,B,or C roofs,FM Approved,ASTM D6878,Dade County Product Approval,ICC-ES Legacy Report/YER-6030 `ritysrcal Vrope rlies ASTM W51 10011013 AS 'I'I0'7$I1 nimuin Ever-Guard Tvpical ; est�ata 1.Certain data is provided in MD(machine direction)x CMD(cross machine direction)format. 2.Data is based upon typical product . rformance,and is subject to normal manufacturing tolerance and variance Nominal Thickness ASTM D-751 0.039"(min.) 0.060" Breaking Strength ASTM D-751 Grab Method 220 lbf/in. 320 lbf x 270 lbf Factory Seam Strength ASTM D-751 66 lbf Pass(membrane failure) Elongation at Break ASTM D-751 15% 28% Heat Aging ASTM D-573 90%Retention of Breaking 100% Strength and Elongation at Break Tear Strength ASTM D-751 8"x 8"Sam.le 551bf 70 lbf x 150 lbf Puncture Resistance FTM 101C Method 2031 Not Established 380 lbs. Cold Brittleness ASTM D-2137 -40 C -40 C Permeance ASTM E-96 Not Established 0.01 Perms Dimensional Change ASTM D-1204 @158 F,6 hrs. +/-1% 0.4% Water Absorption ASTM D-471 @158 F,1 week +/-3.0%(top coating only) 0.7% Hydrostatic Resistance ASTM D-751Method D Not Established 430 psi Ozone Resistance ASTM D-1149 Pass No visible deterioration No visible deterioration @ 7 x magnification @ 7 x magnification Reflectivity ASTM C1549&E408 N/A 0.76 Emissivity ASTM E408 IEI_IIIIIIII 0.90 Product Data Roll Size Note:Product sizes,dimensions,and widths are nominal values and are subject to normal manufacturing/packaging tolerance and variation Colors TulI Roll Size 'aill Roll Viiight Hall.Roll Size IlalfRoll iVeiglit White,Tan,Gray 10'x 100' 322 lbs. 5'x 100' 162 lbs. (1,000 sq.ft.) (500 sq.ft.) Note:Membrane rolls shipped horizontally on pallets. Storage Store rolls on their sides on pallets or shelving in a dry area Salet1 %Yar nung Membrane rolls are heavy,and are best positioned and installed by at least two people *White Membrane Only Product Data Sheet 2 14 GAF I VersaShield UL Fire Barrier Synthetic Roofing Felt/Underlayment Page 2 of 4 • ICC ESR-2053 • ICC AC160 Note:Contact GAF Technical Services at 1-800-ROOF-411 or visit www.gaf.com (/Default.aspx)for acceptable non-asphaltic roofing systems and limited warranty coverage. Property Owner's Best Choice • Superior Protection... The best protection against fire spread and penetration • Looks Better... Fiberglass reinforced,so it lays flatter for a better-looking roof • Peace Of Mind... Up to a Lifetime ltd.warranty when installed on Lifetime Shingle roofs Professional's Best Choice • Increased Productivity... Fire-resistant slip sheet AND roof deck protection in one roll • Convenient... Will upgrade the UL fire classification of almost any type of roof • Safer For Installers... Slip-resistant walking surface improves traction on steep slopes • Easier To Use... Light color provides a cooler working surface • Flexibility... Helps provide temporary moisture resistance;can be left exposed for up to 60 days if necessary VersaShield°Fire-Resistant Roof Deck Protection Physical/Performance Properties Tensile MD ASTM D146/D828 60 lb./in.width CMD ASTM Dl46/D828 30 lb./in.width Tear MD ASTM Dl 922 400 grams CMD ASTM D1922 550 grams Water Vapor Transmission Permeance ASTM E96 3 Perms minimum Liquid Water Transmission Test ASTM D4896 Pass .i n T N • T • / • 1 1 T T , „ i,„,, GAF VersaShield UL Fire Barrier Synthetic Roofing Felt/Underlayment Page 3 of 4 VersaShield®Fire-Resistant Roof Deck Protection Class A Rating Layer Requirements Roofing Material/Type/Min.Thickness 15/32"Plywood Existing Wood Spaced Shake/Shingle Sheathing UL Listed Stone Coated Steel/Direct to deck shingle/0.013" 1 Layer N/A 1 Layer UL Classified or Listed Steel/Direct to deck shingle/0.013" 1 Layer+30 Felt N/A 1 Layer+30 Felt Any UL Classified or Listed Steel/Batten required shingle/0.013" 1 Layer 2 Layers 1 Layer Any UL Classified or Listed Steel/Panel of standing seam/0.015" 1 Layer N/A 1 Layer Any UL Classified or Listed Copper/Panel of standing seam/ 1 Layer N/A 1 Layer 0.016" Any UL Classified or Listed Copper/Shingle/0.016" 1 Layer+30 Felt 2 Layers 1 Layer+30 Felt Any UL Classified or Listed Aluminum/Panel or shingle/0.018" 2 Layers N/A N/A When installed in accordance with section 4.2.1 of GAF's ESR-2053, VersaShield°Fire-Resistant Roof Deck Protection can be used over existing wood shakes or shingles as an alternative to the covering materials specified in section 1510.4 of the IBC, section R907.4 of the IRC, or section 1513.3 of Chapter 15 Appendix to the UBC. U.S. ONLY VersaShield®Fire-Resistant Roof Deck Protection Packaging and Storage 25 rolls per pallet 24 pallets per truck,single stacked, 600 rolls/truck Do NOT double stack Protect from precipitation, moisture, sunlight, and extreme temperatures while in storage • TGFU.R1306-Roofing Systems http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/sho.. • 0) ONLINE CERTIFICATIONS DIRECTORY TGFU.R1306 Roofing Systems page Bottom Roofing Systems See General Information for Roofing Systems GAF R1306 1 CAMPUS DR PARSIPPANY,N)07054 USA "RUBEROID®20 Smooth"or"RUBEROID®Mop Smooth"or"RUBEROID®Mop Smooth 1.5"may be utilized as an alternate to Type G2"GAFGLAS®#75 Base Sheet" or"Tri-Py®#75 Base Sheet"or"GAFGLAS®#80 Ultima•"Base Sheet"base sheets in any of the following Classifications. Vz-in.thick(minimum)gypsum board or 1/4-in.thick(minimum)Georgia-Pacific Gypsum LLC"DensDeck®Roofboard"or"DensDeck®Prime Roofboard"or"DensDeck® DuraGuard'"Roofboard"or 1/4-in.thick(minimum)United States Gypsum Co."SECUROCK®Roof Board"(Type FRX-G)or"SECUROCK®Glass-Mat Roof Board"(Type SGMRX)may be used in any existing noncombustible deck Classification.When this is done,the resulting roofing system is acceptable for use over combustible (15/32-in.thick minimum)roof decks.However,the butt joints in the gypsum board and Georgia-Pacific Gypsum LLC"DensDeck®Roofboard"or"DensDeck®Prime Roofboard"or"DensDeck®DuraGuard"'Roofboard"are to offset a minimum of 6-in.with the butt joints in the roof deck.If polystyrene is part of the roof system,it must be placed below the overlayment board.1/4-In.thick(minimum)"SECUROCK®Roof Board"(Type FRX-G)and"SECUROCK®Glass-Mat Roof Board"(Type SGMRX) are limited to a maximum 3:12 slope when used over a combustible deck in a system with any UL Classed insulation except polystyrene. Multiple plies of Type G1"GAFGLAS®Ply 4"or"Tri-Ply®Ply 4"or"GAFGLAS®Flex Ply 6"or"Tri-Ply®Ultra-Flexible Ply 6"may be adhered to Georgia-Pacific Gypsum LLC"DensDeck®Roofboard"or"DensDeck®Prime Roofboard"or"DensDeck®DuraGuard"Roofboard"in hot roofing asphalt. "GAFGLAS®FlexPly"6 5L"and"GAFGLAS®FlexPly"'6"may be used interchangeably in any roof covering system listed below. "EnergyGuard' Ultra"is an acceptable alternate to"EnergyGuard"'"in any applicable Classification. "GAFGLAS®Stratavent®Mailable Venting Base Sheet"may be mechanically fastened or fully adhered with hot roofing asphalt over noncombustible decks and as a recover over existing roof systems. EnergyGuard"Perlite Insulation"may be utilized as a cover board over"EnergyGuard'""in any of the following systems. Unless otherwise Indicated,the roof insulation is mechanicaly fastened,fully adhered with hot roofing asphalt or UL Classified urethane insulation adhesive.Polystyrene referenced in any of the following Classifications include insulation. Unless otherwise indicated,all insulations may be adhered with any UL Classified Insulation Adhesive per the manufacturer's installation instructions(excluding LRF Adhesive 0)in any applicable Non-Combustible Roof Deck Classifications. "EnergyGuard"Tapered"is an acceptable alternate to"EnergyGuard'""in any applicable Classification. "EnergyGuard'"Ultra Tapered"Ls an acceptable alternate to"EnergyGuard"Ultra"in any applicable Classification. ASPHALT FELT SYSTEMS WITH HOT ROOFING ASPHALT Type G2 asphalt glass mat base sheet("GAFGLAS®#75 Base Sheet"or"Tri-Ply®#75 Base Sheet"or"GAFGLAS®#80 Ultima'"Base Sheet")is a suitable alternate for Type Gi asphalt glass fiber ply sheet("GAFGLAS®Ply 4"or"Tri-Ply®Ply 4"or"GAFGLAS®Flex Ply 6"or"Tri-Ply®Ultra-Flexible Ply 6")in the Class A,B or C roof systems indicated below. The roof deck may first be covered with one ply Type G2 asphalt saturated glass mat base sheet"GAFGLAS®Stratavent®Mailable Venting Base Sheet"or"GAFGLAS® Stratavent®Perforated Venting Base Sheet".Perforated base sheets to be loose laid or fully adhered with hot roofing asphalt and nailable base sheets are to be mechanically fastened granule side down. As an option Type G2 asphalt glass mat base sheet("GAFGLAS®#75 Base Sheet"or"Tri-Ply®#75 Base Sheet"or"GAFGLAS®#80 UltimaTM"Base Sheet"or "GAFGLAS®Stratavent®Mailable Venting Base Sheet")may be substituted for Type G1 asphalt glass fiber ply sheet("GAFGLAS®Ply 4"or'Tri-Ply®Ply 4"or "GAFGLAS®Flex Ply 6"or"Tri-Ply®Ultra-Flexible Ply 6")as the nailed base ply in the following systems. Bottom ply or base sheet may be fully adhered with hot roofing asphalt or mechanicaly fastened. Unless otherwise indicated,all insulations may be fully adhered with hot roofing asphalt or mechanically fastened. "GAFGLAS®Flashing"or"RUBEROID®"may be used for flashing in any of the Class A,B or C systems fisted below. When"perlite"is referenced,this includes any UL Classified perlite insulation. Crushed stones or slag are suitable alternates for gravel in any of the Class A,B or C systems listed. Structural cement fiber building units are considered suitable to be included as a deck in the following Class A,B or C systems listed over C-15/32 or NC. The use of gypsum board under any of the following Class A,B or C systems does not adversely affect the rating.The use of -in.minimum thick gypsum board is an acceptable alternate for minimum insulation over C-15/32 thick roof decks. The use of polystyrene insulation board between minimum 3/4-in.thick perlite board and deck with rosin paper(perlite/rosin paper/polystyrene/perlite)is a suitable alternate for poyisocyanurate board in the following Class A,B or C systems. Trumbull"Perma Mop"may be utilized with any of the following"Asphalt Felt Systems with Hot Roofing Asphalt". "GAFGLAS®#80 Ultima•"Base Sheet"may be used in any of the following systems. 1 of 39 7/14/2016 10:34 AM TGFU.R1306-Roofing Systems http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/sho.. "GAFTEMP Permalite Recover Board"may be used in lieu of any perlite insulation in any of the following NC Classifications. Unless otherwise Indicated,any of the"Asphalt Felt Systems with Hot Roofing Asphalt"may be surfaced with"United Coatings'"FireShield MB Roof Coating"applied at a rate of 21 to 3-gal/100-ft2. Class A,B and C Hot roofing asphalt,for use with glass felts or modified bitumen membranes. "RUBEROID®Heat Weld"SBS roofing membranes may be used in lieu of"RUBEROID®Mop"SBS roofing membranes In any applicable Classification. Class A 1.Deck:C-15/32 Incline:3 Barrier Board(Optional):—One or more layers Georgia-Pacific Gypsum LLC"DensDeck®Roofboard"or"DensDeck®Prime Roofboard"or"DensDeck® DuroGuard"Roofboard",minimum'/4-in.thicck,or United States Gypsum Co."SECUROCK®Roof Board"(Type FRX-G)or"SECUROCK®Glass-Mat Roof Board" (Type SGMRX),minimum'/4-in.thick. Insulation:—One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or urethane or perlite/polyisocyanurate composite or perlite/urethane composite or wood fiber/polyisocyanurate composite or phenolic,any thickness. Ply Sheet:—Three or more plies Type G1"GAFGLAS®Ply 4"or"Tri-Py®Ply 4"or"GAFGLAS®Flex Ply 6"or'Tri-Py®Ultra-Flexible Ply 6",fully adhered with hoot roofing asphalt. Surfacing:—Gravel. 2.Deck:C-15/32 Incline:2 Barrier Board(Optional):—One or more layers Georgia-Pacific Gypsum LLC"DensDeck®Roofboard"or"DensDeck®Prime Roofboard"or"DensDeck® DuraGuard"Roofboard",minimum 1/4-in.thick,or United States Gypsum Co."SECUROCK®Roof Board"(Type FRX-G)or"SECUROCK®Glass-Mat Roof Board" (Type SGMRX),minimum'/4-in.thick. Insulation:—One or more layers perlite or wood fiber or glass fiber or poybocyanurate or urethane or perlite/polyisocyanurate composite or perlite/urethane composite or wood fiber/polyisocyanurate composite or phenolic,any thickness. Ply Sheet:—Three or more plies Type G1"GAFGLAS®Ply 4"or"Tri-Py®Ply 4"or"GAFGLAS®Flex Ply 6"or"Tri-Py®Ultra-Flexible Ply 6",fully adhered with hot roofing asphalt. Cap Sheet:—Type G3"GAFGLAS®Mineral Surfaced Cap Sheet"or"Tri-Py®BUR Granule Cap Sheet"or"GAFGLAS®EnergyCap"Mineral-Surfaced Cap Sheet",fully adhered with hot roofing asphalt. 3.Deck:NC Incline:2 Barrier Board(Optional):—One or more layers Georgia-Pacific Gypsum LLC"DensDeck®Roofboard"or"DensDeck®Prime Roofboard"or"DensDeck® DuraGuard"Roofboard",minimum 1-in.thick,or United States Gypsum Co."SECUROCK®Roof Board"(Type FRX-G)or"SECUROCK®Glass-Mat Roof Board" (Type SGMRX),minimum'/4-in.thick. Insulation(Optional):—One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or urethane or perlite/polyisocyanurate composite or perlite/urethane composite or wood fiber/polyisocyanurate composite or phenolic,2-in.maximum. Ply Sheet:—Two or more plies Type G1"GAFGLAS®Ply 4"or"Tri-Py®Ply 4"or"GAFGLAS®Flex Ply 6"or"Tri-Py®Ultra-Flexible Ply 6",fully adhered with hot roofing asphalt. Cap Sheet:—Type G3"GAFGLAS®Mineral Surfaced Cap Sheet"or"Tri-Py®BUR Granule Cap Sheet"or"GAFGLAS®EnergyCap"Mineral-Surfaced Cap Sheet",fully adhered with hot roofing asphalt. 4.Deck:C-15/32 Incline:1 Slip Sheet(Optional):—Red rosin paper,nailed to deck. Insulation(Optional):—Any thickness perlite or wood fiber or glass fiber or polyisocyanurate mechanically fastened or adhered with 0MG Inc."OlyBond Fastening System"or any UL Classified Insulation adhesive. Base Sheet:—One ply Type G2"GAFGLAS®#75 Base Sheet"or"Tri-Py®#75 Base Sheet"or"GAFGLAS®#80 Ultima"Base Sheet"or"GAFGLAS® Stratavent®Mailable Venting Base Sheet",mechanically fastened. Ply Sheet:—One or more plies Type G1"GAFGLAS®Ply 4"or"Tri-Py®Ply 4"or GAFGLAS®Flex Ply 6"or"Tri-Py®Ultra-Flexible Ply 6",fully adhered with hot roofing asphalt. Cap Sheet:—Type G3"GAFGLAS®Mineral Surfaced Cap Sheet"or"Tri-Py®BUR Granule Cap Sheet"or"GAFGLAS®EnergyCap"Mineral-Surfaced Cap Sheet",fully adhered with hot roofing asphalt. Coating(Optional):—"United Coatings"TOPCOAT®EnergyCote"Roof Coating"or"TOPCOAT®MB Plus Coating"or"United Coatings"Roof Mate MB Plus Coating"applied at a rate of 2-gal./100-ft.2. 5.Deck:NC Incline:3 Base Sheet:—One ply Type G2"GAFGLAS®#75 Base Sheet"or'Tri-Py®#75 Base Sheet"or"GAFGLAS®#80 Ultima"Base Sheet"or"GAFGLAS® Stratavent®Mailable Venting Base Sheet"or"GAFGLAS®Stratavent®Perforated Venting Base Sheet"or"GAFGLAS®Stratavent®Mailable Venting Base Sheet" or"GAFGLAS®Stratavent®Perforated Venting Base Sheet",mechanically fastened or fully adhered with hot roofing asphalt. Ply Sheet:—One or more plies Type G1"GAFGLAS®Ply 4"or"Tri-Py®Ply 4"or"GAFGLAS®Flex Ply 6"or"Tri-Py®Ultra-Flexible Ply 6",fully adhered with hot roofing asphalt. Cap Sheet:—Type G3"GAFGLAS®Mineral Surfaced Cap Sheet"or"Tri-Py®BUR Granule Cap Sheet"or"GAFGLAS®EnergyCap"Mineral-Surfaced Cap Sheet",fully adhered with hot roofing asphalt. 6.Deck:C-15/32 Incline:2 Barrier Board(Optional):—One or more layers Georgia-Pacific Gypsum LLC"DensDeck®Roofboard"or"DensDeck®Prime Roofboard"or"DensDeck® DuraGuard"Roofboard",minimum'/4-in.thick,or United States Gypsum Co."SECUROCK®Roof Board"(Type FRX-G)or"SECUROCK®Glass-Mat Roof Board" (Type SGMRX),minimum'/4-In.thick. Insulation:—One or more layers perlite or glass fiber or polyisocyanurate or urethane or perlite/polyisocyanurate composite or perlite/urethane composite or phenolic,1-in.minimum(offset a minimum of 6-in.from plywood deck joints). Base Sheet:—One or more plies Type G1"GAFGLAS®Ply 4"or"Tri-Py®Ply 4"or"GAFGLAS®Ply Flex 6"or"Tri-Py®Ultra-Flexible Ply 6"or Type G2 "GAFGLAS®#75 Base Sheet"or'Tri-Py®#75 Base Sheet"or"GAFGLAS®#80 Ultima"Base Sheet"or Type G3"GAFGLAS®Mineral Surfaced Cap Sheet"or "Tri-Py®BUR Granule Cap Sheet",mechanicaly fastened or fully adhered with hot roofing asphalt. Membrane:—One or more plies"RUBEROID®Torch Smooth"or"Tri-Py®APP Smooth"or"RUBEROID®Torch Granule"or"RUBEROID®Torch 180"or "Tri-Py®APP Granule",torch applied or"RUBEROID®Mop Smooth"or"RUBEROID®Mop Smooth 1.5"or"RUBEROID®Mop Smooth Plus"or"RUBEROID®Mop Granule"or"Intec Flex PRF"or"Tri-Py®SBS Granule"fully adhered with hot roofing asphalt. Cap Sheet:—Type G3"GAFGLAS®Mineral Surfaced Cap Sheet"or"Tri-Py®BUR Granule Cap Sheet"or"GAFGLAS®EnergyCap"Mineral-Surfaced Cap Sheet",fully adhered with hot roofing asphalt. 2 of 39 7/14/2016 10:34 AJ TGFU.R1306-Roofmg Systems http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/sho... Membrane:—"EverGuard®TPO"45-mil to 60-mil or"EverGuard Extreme®TPO"50-mil to 60-mil,fully adhered with"EverGuard®#1121 Bonding Adhesive" or"EverGuard®TPO 3 Square Low VOC Bonding Adhesive 1168"or"EverGuard®TPO 3 Square Low VOC Bonding Adhesive"applied at a rate of 60-ft.2/gal. 6.Deck:C-15/32 Incline:1/4 Insulation:—Minimum 11/4-in.thick"EnergyGuard"Ultra"mechanically fastened with butt joints in the insulation staggered a minimum of 12-in.from test deck plywood joints. Membrane:—"EverGuard®TPO FB Ultra"45-mil to 60-mil or"EverGuard Extreme®TPO FB Ultra"50-mil to 60-mil fully adhered with"EverGuard®WB 181 Bonding Adhesive"applied at a rate of 120-R.2/gal. 7.Deck:C-15/32 Incline:1/2 Insulation:—Minimum 1'/2-in.thick"EnergyGuard"Ultra"mechanically fastened with butt joints in the insulation staggered a minimum of 12-In.from test deck plywood joints. Membrane:—"EverGuard®TPO"45-mil to 60-mil or"EverGuard Extreme®TPO"50-mil to 60-mil fully adhered with"EverGuard®#1121 Bonding Adhesive" or"EverGuard®TPO 3 Square Low VOC Bonding Adhesive 1168"or"EverGuard®TPO 3 Square Low VOC Bonding Adhesive"applied at a rate of 60-ft.2/gal. 8.Deck:C-15/32 Incline:1/2 Insulation:—Minimum 11/2-in.thick"EnergyGuard"Ultra"mechanically fastened with butt joints in the insulation staggered a minimum of 12-in.from test deck plywood joints. Membrane:—EverGuard®TPO FB Ultra"45-mil to 80-mil or"EverGuard Extreme®TPO FB Ultra"50-mil to 80-mil,fully adhered with"EverGuard®H2O Bonding Adhesive"or"EverGuard®WB 181 Bonding Adhesive",applied at a rate of 120-ft.2/gal.or adhered with"LRF Adhesive M"or"LRF Adhesive 0",applied as a nominal 3k-in.diameter bead with a maximum on-center spacing of 12-in.,applied parallel to the slope of the roof. Class C-Fully Adhered 1.Deck:NC Incline:1/2 Insulation:—"EnergyGuard""or"EnergyGuard"Ultra"or"EnergyGuard"RA"or"EnergyGuard"RN"or"EnergyGuard"RH"or"EnergyGuard"RF"or "EnergyGuard"RM"or wood fiber or glass fiber or perlite,any thickness. Cover Board(Optional):—'h-in.thick"EnergyGuard"'HD"or 1/2-in.thick"EnergyGuard"HD Plus",mechanically fastened. Membrane:—"EverGuard®TPO"45-mil to 60-mil or"EverGuard Extreme®TPO"50-mil to 60-mil,fully adhered with"EverGuard®#1121 Bonding Adhesive" or"EverGuard®TPO 3 Square Low VOC Bonding Adhesive 1168"or"EverGuard®TPO 3 Square Low VOC Bonding Adhesive"applied at a rate of 60-ft.2/gal. 2.Deck:C-15/32 Incline:Unlimited Base Sheet:—One ply"VersaShield®Fire-Resistant Roof Deck Protection",mechanically fastened. Membrane:—"EverGuard®TPO"45-mil to 80-mil or"EverGuard Extreme®TPO"50-mil to 80-mil,fully adhered with"EverGuard®#1121 Bonding Adhesive", applied at a rate of 1-gal./60-ft.2 or"EverGuard®TPO FB Ultra"45-mil to 80-mil or"EverGuard Extreme®TPO FB Ultra"50-mil to 80-mil,fully adhered with "EverGuard®WB 181 Bonding Adhesive",applied at a rate of 120-ft.2/gal.or"EverGuard®TPO 3 Square Low VOC Bonding Adhesive 1168"or"EverGuard® TPO 3 Square Low VOC Bonding Adhesive"applied at 60-ft.2/gal."EverGuard®Freedom"TPO"45-mil to 80-mil,self-adhered. 3.Deck:NC Incline:1/4 Insulation(Optional):—"EnergyGuard""or"EnergyGuard"Ultra"or"EnergyGuard"RA"or"EnergyGuard"RN"or"EnergyGuard"RH"or"EnergyGuard" RF"or"EnergyGuard"RM"or wood fiber or glass fiber or perlite,any thickness. Cover Board(Optional):—'h-In.thick"EnergyGuard"HD"or' -in.thick"EnergyGuard"HD Plus",mechanically fastened. Membrane:—"EverGuard®TPO"45-mil to 80-mil or"EverGuard Extreme®TPO"50-mil to 80-mil,fully adhered with"EverGuard®Low VOC TPO Bonding Adhesive",applied at a rate of 120-ft.2/gat.or"EverGuard®TPO 3 Square Low VOC Bonding Adhesive 1168"or"EverGuard®TPO 3 Square Low VOC Bonding Adhesive"applied at 60-ft.2/gal. SINGLE PLY MEMBRANE ROOFING SYSTEMS(TPO) Class A-Mechanically Fastened 1.Deck:NC Incline:1/2 Barrier Board(Optional):—One or more layers Georgia-Pacific Gypsum LLC"DensDeck®Roofboard"or"DensDeck®Prime Roofboard"or"DensDeck® DuraGuard"Roofboard",minimum'/4-in.thick,or United States Gypsum Co."SECUROCK®Roof Board"(Type FRX-G)or"SECUROCK®Glass-Mat Roof Board" (Type SGMRX),minimum 1/4-in.thick. Insulation(Optional):—"EnergyGuard""or"EnergyGuard"Ultra"or"Energy Guard"RF"or"EnergyGuard"RA"or"EnergyGuard"RN"or"EnergyGuard" RH"or"EnergyGuard"RM"or wood fiber or glass fiber or perlite,any thickness,mechanically fastened. Cover Board(Optional):—' -in.thick"EnergyGuard"HD"or 1-in.thick"EnergyGuard"HD Plus",mechanically fastened. Membrane:—"EverGuard®TPO"45-mil to 80-mil or"EverGuard Extreme®TPO"50-mil to 80-mil,mechanically fastened. 2.Deck:NC Incline:2' Insulation(Optional,see note):—Any UL Classified,any thickness. Barrier Board(Optional,see note):—Minimum' -in.thick gypsum board or'/4-in.thick Georgia-Pacific Gypsum LLC"DensDeck®Roofboard"or"DensDeck® Prime Roofboard"or"DensDeck®DuraGuard"Roofboard"or minimum'/4-in.thick United States Gypsum Co."SECUROCK®Roof Board"(Type FRX-G)"or "SECUROCK®Glass-Mat Roof Board"(Type SGMRX). Membrane:—"EverGuard®TPO"45-mil to 60-mil or"EverGuard Extreme®TPO"50-mil to 60-mil,mechanically fastened. Note:—A Barrier Board is required when insulation is present. 3.Deleted. 4.Deck:NC Incline:1/2 Barrier Board(Optional):—One or more layers Georgia-Pacific Gypsum LLC"DensDeck®Roofboard"or"DensDeck®Prime Roofboard"or"DensDeck® DuraGuard'Roofboard",minimum'/4-in.thick,or United States Gypsum Co."SECUROCK®Roof Board"(Type FRX-G)or"SECUROCK®Glass-Mat Roof Board" (Type SGMRX),minimum Vs-in.thick. Insulation(Optional):—"EnergyGuardTM"or"EnergyGuard"RA"or"EnergyGuard"RF""EnergyGuard"Ultra"or"EnergyGuardTM'RN"or"EnergyGuard"RH" or"EnergyGuard"RM"or wood fiber or glass fiber or perlite,any thickness,mechanically fastened. Cover Board(Optional):—' -in.thick"EnergyGuard"HD"or'-in.thick"EnergyGuard"HD Plus",mechanically fastened. Membrane:—"EverGuard®TPO FB Ultra"45-mil to 80-mil or"EverGuard Extreme®TPO FB Ultra"50-mil to 80-mil,mechanically fastened. of 19 7/14/2016 10:34 AM TGFU.R1306-Roofing Systems http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/sho.. 5.Deck:C-15/32 Incline:1/2 Primer:—"TOPCOAT@ FireOut"Fire Barrier Coating"or"FireOut"Fire Barrier Coating",applied at a rate of 1-gal./100-ft.2. Base Sheet(Optional):—One ply Type G2"GAFGLAS@#75 Base Sheet"or"Tri-Ply@#75 Base Sheet"or"GAFGLAS@#80 Ultima"'Base Sheet"or "GAFGLAS@ Stratavent@ Nafable Venting Base Sheet",mechanicaly fastened. Slip Sheet(Optional):—One ply"VersaShield@ Solo"'Fire Resistant Sllpsheet,mechanicaly fastened. Membrane:—"EverGuard@ TPO"45-mi to 80-mil or"EverGuard Extreme@ TPO"50-mil to 80-mil,mechanically fastened. 6.Deck:NC Incline:1/2 Barrier Board(Optional):—Minimum 1/4-in.thick Georgia-Pacific Gypsum LLC"DensDeck@ Roofboard"or"DensDeck®Prime Roofboard"or"DensDeck@ DuraGuard"Roofboard"or minimum'h.-in.thick gypsum wallboard or United States Gypsum Co."SECUROCK@ Roof Board"(Type FRX-G)or"SECUROCK@ Glass-Mat Roof Board"(Type SGMRX),mechanically fastened. Slip Sheet(Optional):—One ply"VersaShield@ Fire-Resistant Roof Deck Protection",mechanically fastened. Base Sheet(Optional):—One ply Type 15 or Type 30 or Type 61"GAFGLAS@ Ply 4"or"Tri-Py@ Ply 4"or"GAFGLAS@ Flex Ply 6"or'Tri-Py@ Ultra-Flexible Ply 6"or Type G2"GAFGLAS@#75 Base Sheet"or"Tri-Py@#75 Base Sheet"or'GAFGLAS@#80 Ultima"Base Sheet"or"GAFGLAS@ Stratavent@ Nailable Venting Base Sheet"or"GAFGLAS@ Stratavent@ Perforated Venting Base Sheet",mechanically fastened or fully adhered with hot roofing asphalt. Membrane:—"EverGuard®TPO"45-mil to 80-mil or"EverGuard Extreme@ TPO"50-mil to 80-mil or"EverGuard®TPO FB Ultra"45-mil to Bo-mil or "EverGuard Extreme@ TPO FB Ultra"50-mil to 80-mil,mechanically fastened. Surfacing:—United Solar Ovonics Field-Assembled Photovoltaic(Solar)Module Systems"PVL-29,-31,-58,-60,-62,-64,-68,-87,-93,-116,-120,-124, -128,-136",self-adhered. 7.Deck:C-15/32 Incline:1/2 Slip Sheet:—Two plies"VersaShield@ Fire-Resistant Roof Deck Protection"or one ply"VersaShield@ Sob"Fire Resistant Slipsheet",mechanically fastened. Membrane:—"EverGuard®TPO FB Ultra"45-mil to 80-mil or"EverGuard Extreme@ TPO FB Ultra"50-mil to 80-mil,mechanically fastened. 8.Deck:C-15/32 Incline:1/2 Slip Sheet:—Two plies"VersaShield@ Fire-Resistant Roof Deck Protection"or one ply"VersaShield@ Solo"'Fire Resistant Slipsheet",mechanically fastened. Insulation:—"EnergyGuard"""or"EnergyGuard"RF"or"EnergyGuard"Ultra,"or"EnergyGuard"RA"or"EnergyGuard"RN"or"EnergyGuard"RH"or "EnergyGuard"RM",any thickness or any UL Classified wood fiber,mechanically fastened. Cover Board(Optional):—'h-in.thick"EnergyGuard""HD"or'k-in.thick"EnergyGuard"HD Plus",mechanically fastened. Membrane:—"EverGuard®TPO"45-mil to 80-mil or"EverGuard Extreme@ TPO"50-mil to 80-mil,mechanically fastened. 9.Deck:C-15/32 Incline:3/4 Slip Sheet:—Two plies"VersaShield@ Solo"Fire Resistant Slipsheet",mechanically fastened. Insulation:—"EnergyGuard"""or"EnergyGuard"Ultra"or"EnergyGuard"RA"or"EnergyGuard"RN"or"EnergyGuard"RH"or"EnergyGuard"RF"or "EnergyGuard"RM",any thickness or any UL classified wood fiber board,mechanically fastened. Cover Board(Optional):—1/2-in.thick"EnergyGuard"HD"or grin.thick"EnergyGuard"HD Plus",mechanically fastened. Membrane:—"EverGuard®TPO"45-mil to 80-mil or"EverGuard Extreme@ TPO"50-mil to 80-mil,mechanically fastened. 10.Deck:C-15/32 Incline:1/2 Slip Sheet:—Two plies"VersaShield®Fire-Resistant Roof Deck Protection"or one ply"VersaShield@ Solo"'Fire Resistant Slipsheet",mechanically fastened. Insulation:—"EnergyGuard."'"or"EnergyGuard"RF"or"EnergyGuard"Ultra"or"EnergyGuard"RA"or"EnergyGuard"RN"or"EnergyGuard"RH"or "EnergyGuard"RM",any thickness or any UL classified wood fiber board,mechanically fastened. Cover Board(Optional):—'/2-in.thick"EnergyGuard"HD"or V2-in.thick"EnergyGuard""HD Plus",mechanicaly fastened. Membrane:—"EverGuard®TPO"45-mil to 80-mil or"EverGuard Extreme@ TPO"50-mil to 80-mil,mechanically fastened. 11.Deleted. 12.Deleted. 13.Deleted. 14.Deck:C-15/32 Incline:Unlimited Slip Sheet:—One or more plies"VersaShield@ Sob"Fire Resistant Slipsheet",mechanically fastened. Insulation:—Any UL Classified,any thickness,any combination,one or more layers(except EPS and wood fiberboard),mechanically fastened. Membrane:—Any UL Classified GAF or Duro-Last Inc.mechanically fastened(membrane must be currently Certified for use over the insulation used.Actual Incline is determined by the membrane/insulation Certification.This Certification is only for use with GAF or Duro-Last Inc.TPO membranes). 15.Deck:NC Incline:2 Insulation:—Polystyrene or EPS or beadboard,any thickness,mechanically fastened. Slip Sheet:—One ply"VersaShield®Fire-Resistant Roof Deck Protection"or two plies"VersaShield@ Sob"Fire Resistant Slipsheet",mechanically fastened. Membrane:—Any UL Classified(membrane must be currently Classified for use over the insulation used.Actual Incline is determined by the existing membrane/insulation Classification),mechanically fastened. 16.Deleted. 17.Deleted. 18.Deck:NC Incline:2 Membrane:—"EverGuard®TPO FB Ultra"45-mil to 80-mil or"EverGuard Extreme@ TPO FB Ultra"50-mil to 80-mil,mechanically fastened. 19.Deck:C-15/32 Incline:2' Slip Sheet:—One or more plies"VersaShield@ Sob"Fire Resistant Slipsheet"mechanically fastened. Membrane:—45 to 60 mil"EverGuard®TPO"or"EverGuard®Extreme@ TPO"mechanically attached. 20.Deck:C-15/32 Incline:3/4 Slip Sheet:—One or more plies"VersaShield@ Solo"Fire Resistant Slipsheet"mechanically fastened. Membrane:—80-mil"EverGuard®TPO"or"EverGuard®Extreme@ TPO",mechanically attached. 34 of 39 7/14/2016 10:34 AI\ TGFU.R1306-Roofing Systems http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/sho... 21.Deck:C-15/32 Incline:Unlimited,See Note 1 Slip Sheet:—One or more plies"VersaShield®Solo"Fire Resistant Slipsheet"mechanically fastened. Membrane:—Any UL Certified GAF or Duro-Last Inc.TPO mechanically fastened Note 1:Certification and maximum incline will be the same as that of the Certified GAF or Duro-Last Inc.Roofing System(TGFU)currently limited to noncombustible roof deck.This listing is only for use with GAF or Duro-Last Inc.TPO membranes. 22.Deck:C-15/32 Incline:1/2 Insulation:—"Minimum 3-in.thick"EnergyGuard"Ultra"mechanically fastened with butt joints in the insulation staggered a minimum of 12-in.from test deck plywood joints. Membrane:—"EverGuard®TPO"45-mil to 80-mil or"EverGuard®Extreme"'TPO"50-mil to 80-mil mechanically fastened. Class B-Mechanically Fastened 1.Deck:NC Incline:Unlimited Membrane:—"EverGuard®TPO"45-mil to 60-mil or"EverGuard Extreme®TPO"50-mil to 60-mil,mechanically fastened. 2.Deck:C-15/32 incline:1/2 Slip Sheet:—One or more plies of Atlas Roofing Corp."FR-50",mechanically fastened. Membrane:—"EverGuard®TPO"45-mil to 80-mil or"EverGuard Extreme®TPO"50-mil to 80-mil,mechanically fastened. 3.Deleted. 4.Deck:C-15/32 Incline:1/2 Slip Sheet:—One or more plies Atlas Roofing Corp."FR-10",mechanically fastened. Membrane:—"EverGuard®TPO"45-mil to 80-mil or"EverGuard Extreme®TPO"50-mil to 80-mil,mechanically fastened. 5.Deck:C-15/32 Incline:3 Primer:—"TOPCOAT®FireOut•"Fire Barrier Coating"or"FireOut"'Fire Barrier Coating",applied at a rate of 1-gal./100-ft.2. Membrane:—"EverGuard®TPO"45-mil to 80-mil or"EverGuard Extreme®TPO"50-mil to 80-mil,mechanically fastened. 6.Deck:C-15/32 Incline:1/2 Slip Sheet:—One ply"VersaShield®Solo"'Fire Resistant Slipsheet",mechanically fastened. Membrane:—"EverGuard®TPO"45-mil to 80-mil or"EverGuard Extreme®TPO"50-mil to 80-mil,mechanically fastened. 7.Deck:C-15/32 Incline:2 Insulation:—Polystyrene or EPS or beadboard,any thickness,mechanically fastened. Slip Sheet:—One or more plies"VersaShield®Solo"'Fire Resistant Slipsheet",mechanically fastened. Membrane:—Any UL Classified(membrane must be currently Classified for use over the Insulation used.Actual incline is determined by the existing membrane/insulation Classification,but cannot exceed 2:12),mechanically fastened. 8.Deck:C-15/32 Incline:1/2 Insulation:—Minimum 11/2-In.thick"EnergyGuard"Ultra"mechanically fastened with butt joints in the insulation staggered a minimum of 12-in.from test deck plywood joints. Membrane:—"EverGuard®TPO"45-mil to 80-mil or"EverGuard®Extreme"TPO"50-mil to 80-mil mechanically fastened. MAINTENANCE AND REPAIR SYSTEMS(PVC) Class A 1.Deck:NC Incline:1/2 Existing Roof System:—Insulated or noninsulated cap sheet,smooth or gravel surfaced(loose gravel may be removed). Barrier Board(Optional):—Minimum 1h-in.thick plywood. Insulation/Slip Sheet:—One of the following Insulations or insulatlorVslip sheet combinations: a.Perlite,any thickness/(optional)One ply Atlas Roofing Corp."FR-10". b."EnergyGuard""or"EnergyGuard"Ultra"or"EnergyGuard"'RA"or"EnergyGuard"'RN"or"EnergyGuard"RH"or"EnergyGuard"'RF"or"EnergyGuard" RM",any thickness/One ply Atlas Roofing Corp."FR-10". c.Dow Chemical"Styrofoam SM",any thickness/One ply Atlas Roofing Corp."FR-10". d.BASF EPS(uniform or tapered),any thickness,covered with perlite(3/4-in.min)/(optional)One ply Atlas Roofing Corp."FR-10". e.ARCO Chemical"ARCOR MB"or"ARCOR FM-1",1.6-in.minimum. Membrane:—"EverGuard®PVC XK"or"EverGuard®PVC Smooth"50 to 80-mil,mechanically fastened. 2.Deck:NC Incline:1 Existing Roof System:—Insulated or non-insulated cap,sheet smooth or gravel surfaced(loose gravel may be removed). Barrier Board(Optional):—Minimum grin.thick plywood or Georgia-Pacific Gypsum LLC"DensDeck®Roofboard"or"DensDeck®Prime Roofboard"or "DensDeck®DuraGuard"Roofboard",minimum'/a-in.thick,or United States Gypsum Co."SECUROCK®Roof Board"(Type FRX-G)or"SECUROCK®Glass-Mat Roof Board"(Type SGMRX),minimum 1/4-in.thick. Insulation:—"EnergyGuard""or"EnergyGuard"Ultra"or"EnergyGuard"RA"or"EnergyGuard"RN"or"EnergyGuard"RH"or"EnergyGuard"RF"or "EnergyGuard"RM",mechanically fastened,any thickness. Membrane:—"EverGuard®PVC XK"or"EverGuard®PVC Smooth"(PVC)50 to 80-mil,mechanically fastened. 3.Deck:C-15/32 Incline:1 35 of 39 7/14/2016 10:34 AM TGFU.R1306-Roofmg Systems http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/sho. Existing Roof System:—Insulated or non-insulated cap sheet,smooth or gravel surfaced(loose gravel may be removed from noncombustible decks)or PVC roof system,covered with: Barrier Board(Optional):—Minimum IA-in.thick Georgia-Pacific Gypsum LLC"DensDeck®Roofboard"or"DensDeck®Prime Roofboard"or"DensDeck® DuraGuardTM Roofboard",or United States Gypsum Co."SECUROCK®Roof Board"(Type FRX-G)or"SECUROCK®Glass-Mat Roof Board"(Type SGMRX), minimum y4-in.thick. Membrane:—"EverGuard®PVC XK"or"EverGuard®PVC Smooth"(PVC)50 to 80-mil,mechanically fastened. Class B 1.Deck:C-15/32 Incline:1 Existing Roof System:—Insulated or non-insulated cap sheet smooth or gravel surfaced(loose gravel may be removed from noncombustible decks)Class B to retain the existing Classification is covered with: Barrier Board:—Minimum I/2-in.thick Johns Manville International Inc."Retro-Fit Board"or minimum'/4-in.thick Georgia-Pacific Gypsum LLC"DensDeck® Roofboard"or"DensDeck®Prime Roofboard"or"DensDeck®DuraGuard"Roofboard"or minimum IA-in.thick United States Gypsum Co."SECUROCK®Roof Board"(Type FRX-G)"or"SECUROCK®Glass-Mat Roof Board"(Type SGMRX),mechanically fastened or fully adhered with hot roofing asphalt or adhered with "LRF Adhesive M"or any other UL Classified foamed plastic insulation adhesive,applied per the manufacturer's installation instructions. Membrane:—"EverGuard®PVC XK Fleeceback"50 to 80-mil,mechanically fastened or"fully adhered with hot roofing asphalt or adhered with"LRF Adhesive M"or"LRF Adhesive 0",applied as a nominal3/4-in.diameter bead with a maximum on-center spacing of 12-in.,applied parallel to the slope of the roof. Class A,B or C 1.Deck:C-15/32 Incline:1 Existing Roof System:—Class A,B or C insulated(any thickness wood fiber or perlite or polyisocyanurate or urethane or polystyrene with a slip sheet). Polyester Fleece:—One ply 2.5-oz./yd.2(maximum)polyester fleece. Membrane:—"EverGuard®PVC XK"or"EverGuard®PVC Smooth"50 to 80-mil,mechanically fastened. 2.Deck:C-15/32 Incline:1 Existing Roof System:—Class A,B or C insulated(any thickness wood fiber or perlite or polyisocyanurate or urethane or polystyrene with a slip sheet). Polyester Fleece:—One layer 2.5-oz./yd.2(maximum)polyester fleece. Membrane:—"EverGuard®PVC XK"or"EverGuard®PVC Smooth"50 to 80-mil,mechanically fastened. 3.Deck:C-15/32 Incline:1 Existing System:—Class A,B or C built-up system,smooth surface,cap sheet or gravel surfaced,gravel to be maintained at 400-lbs./100 ft.2 to retain existing Classification. Slip Sheet:—One ply Altas Roofing Corp."FR10"or"FR11". Membrane:—"EverGuard®PVC XK"or"EverGuard®PVC Smooth"50 to 80-mil,mechanically fastened. 4.Deck:NC Incline:1 Existing Roof System:—Class A,B or C insulated or non-insulated roof covering system(for gravel surfaced BUR systems,loose gravel may be removed)to maintain the Class A,B or C rating covered with: Barrier Board(Optional):—Minimum'/x-in.thick plywood or minimum IA-in.thick Georgia-Pacific Gypsum LLC"DensDeck®Roofboard"or"DensDeck®Prime Roofboard"or"DensDeck®DuraGuard'"Roofboard"or minimum 1/44-in.thick United States Gypsum Co."SECUROCK®Roof Board"(Type FRX-G)"or "SECUROCK®Glass-Mat Roof Board"(Type SGMRX),mechanically fastened. Insulation:—Minimum 1-in.thick"EnergyGuard'""or"EnergyGuard'"RA"or"EnergyGuard'rm RN"or"EnergyGuard'"RF"or"EnergyGuard'"Ultra"or "EnergyGuard RH"or"EnergyGuard'''RM",mechanically fastened or fully adhered with hot roofing asphalt or adhered with"LRF Adhesive M"or OMG Inc. "Olybond Fastening System",applied as a nominal3A-in.bead or"GAF 2-Part Roofing Adhesive",applied as a nominal 21-in,bead with a maximum on-center spacing of 12-in.or any UL Classified insulation adhesive,applied per the manufacturer's installation instructions. Membrane:—"EverGuard®PVC XK Fleeceback"50 to 80-mil,fully adhered with hot roofing asphalt or adhered with"LRF Adhesive M"or"LRF Adhesive 0", applied as a nominal 3A-in.diameter bead with a maximum on-center spacing of 12-in.,applied parallel to the slope of the roof. 5.Deck:C-15/32 Incline:3 Existing Roof System:—Class A,B or C insulated or noninsulated roof covering system(for gravel surfaced BUR systems,loose gravel may be removed)to maintain the Class A,B or C rating covered with: Barrier Board:—Minimum 1/4-in.thick Georgia-Pacific Gypsum LLC"DensDeck®Roofboard"or"DensDeck®Prime Roofboard"or"DensDeck®DuraGuard'" Roofboard"or minimum'/4-in.thick United States Gypsum Co."SECUROCK®Roof Board"(Type FRX-G)"or"SECUROCK®Glass-Mat Roof Board"(Type SGMRX). Membrane:—"EverGuard®PVC XK Fleeceback"(PVC)50 to 80-mil,fully adhered with hot roofing asphalt or adhered with"LRF Adhesive M"or"LRF Adhesive 0",applied as a nominal/-in.diameter bead with a maximum on-center spacing of 12-in.,applied parallel to the slope of the roof. MAINTENANCE AND REPAIR SYSTEMS(TPO) Class A 1.Deck:NC Incline:1/2 Existing Roof System:—Class A,B or C insulated or noninsulated roof covering system(for gravel surfaced BUR systems,loose gravel may be removed)to maintain the Class A,B or C rating,covered with: Barrier Board(Optional):—Minimum 1-in.thick*wood or minimum 1/2-in.thick Johns Manville International Inc."Retro-Fit Board"or minimum 1/4-in.thick Georgia-Pacific Gypsum LLC"DensDeck®Roofboard"or"DensDeck®Prime Roofboard"or"DensDeck®DuraGuard'"Roofboard"or minimum'-in.thick United States Gypsum Co."SECUROCK®Roof Board"(Type FRX-G)or"SECUROCK®Glass-Mat Roof Board"(Type SGMRX),mechanically fastened or fully adhered with hot roofing asphalt or adhered with"LRF Adhesive M"or any other UL Classified foamed plastic insulation adhesive,applied per the manufacturer's installation instructions. Insulation:—Minimum 1-in.thick"EnergyGuard'""or"EnergyGuard'"RA"or"EnergyGuard"RN"or"EnergyGuard*"RF"or"EnergyGuard'"Ultra"or "EnergyGuard.'RH"or"EnergyGuard'"RM",mechanically fastened or fully adhered with hot roofing asphalt or adhered with"LRF Adhesive M"or OMG Inc. "Olybond Fastening System",applied as a nominal3A-in.bead or"GAF 2-Part Roofing Adhesive",applied as a nominal 21/2-in.bead with a maximum on-center spacing of 12-in.or any UL Classified insulation adhesive,applied per the manufacturer's installation instructions. Cover Board(Optional):—1-in.thick"EnergyGuard*"HD"or Ih-in.thick"EnergyGuard'"HD Plus",mechanically fastened. Membrane:—"EverGuard®TPO FB Ultra"45-mil to 80-mil or"EverGuard Extreme®TPO FB Ultra"50-mil to 80-mil,fully adhered with hot roofing asphalt or adhered with"LRF Adhesive M"or"LRF Adhesive 0",applied as a nominal 3/4-in.diameter bead with a maximum on-center spacing of 12-in.,applied parallel to the slope of the roof. 36 of 39 7/14/2016 10:34 AT TGFU.R1306-Roofing Systems http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/sho... 2.Deck:C-15/32 Incline:21h Existing Roof System:—Class A,B or C insulated or non-insulated roof covering system(for gravel surfaced BUR systems,loose gravel may be removed)to maintain the Class A,B or C rating covered with: Barrier Board:—Minimum 1/4-in.thick Georgia-Pacific Gypsum LLC"DensDeck®Roofboard"or"DensDeck®Prime Roofboard"or"DensDeck®DuraGuard'" Roofboard"or minimum 1-in.thick United States Gypsum Co."SECUROCK®Roof Board"(Type FRX-G)or"SECUROCK®Glass-Mat Roof Board"(Type SGMRX),mechanically fastened or fully adhered with hot roofing asphalt or adhered with"LRF Adhesive M"or any other UL Classified foamed plastic insulation adhesive applied per the manufacturer's installation instructions. Membrane:—"EverGuard®TPO FB Ultra"45-mil to 80-mil or"EverGuard Extreme®TPO FB Ultra"50-mil to 80-mil,fully adhered with hot roofing asphalt or adhered with"LRF Adhesive M"or"LRF Adhesive 0",applied as a nominal 3/4-in.diameter bead with a maximum on-center spacing of 12-In.,applied parallel to the slope of the roof. Class B 1.Deck:C-15/32 Incline:1 Existing Roof System:—Insulated or non-insulated mineral surfaced cap sheet,smooth surfaced or gravel surfaced BUR(loose gravel may be removed from noncombustible roof decks)or PVC,TPO,Hypalon or EPDM polymeric single ply membrane Class B roof covering system to retain the existing classification is covered with: Barrier Board:—Minimum 1/2-in.thick Johns Manville International Inc."Retro-Fit Board"or minimum'/4-in.thick Georgia-Pacific Gypsum LLC"DensDeck® Roofboard"or"DensDeck®Prime Roofboard"or"DensDeck®DuraGuard" Roofboard"or minimum 1/4-in.thick United States Gypsum Co."SECUROCK®Roof Board"(Type FRX-G)or"SECUROCK®Glass-Mat Roof Board"(Type SGMRX),mechanically fastened or fully adhered with hot roofing asphalt or adhered with "LRF Adhesive M"or any other UL Classified foamed plastic insulation adhesive,applied per the manufacturer's installation Instructions. Membrane:—"EverGuard®TPO FB Ultra"45-mil to 80-mil or"EverGuard Extreme®TPO FB Ultra"50-mil to 80-mil,fully adhered with hot roofing asphalt or adhered with"LRF Adhesive M"or"LRF Adhesive 0",applied as a nominal 3/4-in.diameter bead with a maximum on-center spacing of 12-in.,applied parallel to the slope of the roof. MAINTENANCE AND REPAIR SYSTEMS Unless otherwise indicated,these constructions are intended for installation over an existing Class A,B or C system. Class A,B or C 1.Deleted. 2.Deleted. 3.Deleted. 4.Deleted. 5.Deleted. 6.Deck:C-15/32 Incline:3/4 Existing Roof System:—Class A,B or C system to retain the existing Classification covered with: Membrane:—"EverGuard®TPO FB Ultra"60-mil to 80-mil or"EverGuard Extreme®TPO FB Ultra"60-m0 to 80-mil,fully adhered with hot roofing asphalt or mechanically fastened. 7.Deck:C-15/32 Incline:1/2 Existing Roof System:—Class A,B or C system to retain the existing Classification covered with: Membrane:—"EverGuard®TPO FB Ultra"60-mil to 80-mil or"EverGuard Extreme®TPO FB Ultra"60-mil to 80-mil,fully adhered with"EverGuard®H2O Bonding Adhesive"or"EverGuard WB 181 Bonding Adhesive"applied at a rate of 120-ft.2/gal.,applied at a rate of 180-ft 2/gal. 8.Deck:C-15/32 Incline:1/2 Existing Roof System:—Class A,B or C system to retain the existing Classification covered with: Membrane:—"EverGuard®TPO FB Ultra"60-mil to 80-mil or"EverGuard Extreme®TPO FB Ultra"60-mil to 80-mil,fully adhered with ITW-TACC"TACC 636", applied at a rate of 120-ft.2/gal. 9.Deck:C-15/32 Incline:3/4 Existing Roof System:—Class A,B or C system to retain the existing Classification covered with: Barrier Board(Optional):—One or more layers Georgia-Pacific Gypsum LLC"DensDeck®Roofboard"or"DensDeck®Prime Roofboard"or"DensDeck® DuraGuard'"Roofboard",minimum 1/4-in.thick,or United States Gypsum Co."SECUROCK®Roof Board"(Type FRX-G)or"SECUROCK®Glass-Mat Roof Board" (Type SGMRX),minimum 1/4-in.thick. Insulation:—Wood fiber or glass fiber or perlite,1-in.thick minimum or gypsum board. Membrane:—"EverGuard®TPO FB Ultra"45-mil to 80-mil or"EverGuard Extreme®TPO FB Ultra"50-mil to 80-mil,fully adhered with hot roofing asphalt or mechanically fastened. 10.Deck:C-15/32 Incline:1/2 Existing Roof System:—Class A,B or C system to retain the existing Classification covered with: Barrier Board(Optional):—One or more layers Georgia-Pacific Gypsum LLC"DensDeck®Roofboard"or"DensDeck®Prime Roofboard"or"DensDeck® DuraGuard"Roofboard",minimum Mr-in.thick,or United States Gypsum Co."SECUROCK®Roof Board"(Type FRX-G)or"SECUROCK®Glass-Mat Roof Board" (Type SGMRX),minimum 1/4-1n.thick. Insulation:-Wood fiber or glass fiber or perlite' -in.thick minimum gypsum board,rh-in.thick minimum. Membrane:—"EverGuard®TPO FB Ultra"45-mil to 80-mil or"EverGuard Extreme®TPO FB Ultra"50-mil to 80-mil,fully adhered with"EverGuard®WB 181 Bonding Adhesive"or"EverGuard®H2O Bonding Adhesive",applied at a rate of 120-ft.2/gal. 11.Deck:C-15/32 Incline:1/2 Existing Roof System:—Class A,B or C system to retain the existing Classification covered with: Barrier Board(Optional):—One or more layers Georgia-Pacific Gypsum LLC"DensDeck®Roofboard"or"DensDeck®Prime Roofboard"or"DensDeck® DuraGuard'"Roofboard",minimum'/4-in.thick,or United States Gypsum Co."SECUROCK®Roof Board"(Type FRX-G)or"SECUROCK®Glass-Mat Roof Board" (Type SGMRX),minimum 1/4-in.thick. Insulation:—Wood fiber or glass fiber or perlite 1-in.thick minimum or gypsum board. Membrane:—"EverGuard®TPO FB Ultra"45-mil to 80-mil or"EverGuard Extreme®TPO FB Ultra"50-mil to 80-mil,fully adhered with ITW-TACC"TACC 636", 27.,f 10 7/14/7(116 10.14 AM TGFU.R1306-Roofmg Systems http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/sho: applied at a rate of 120-ft.2/gal. 12.Deck:C-15/32 Incline:2 Existing Roof System:—Class A,B or C insulated or noninsulated BUR cap sheet system to retain the existing Classification covered with: Membrane:—"EverGuard®TPO FB Ultra"60-mil to 80-mil or"EverGuard Extreme@ FB Ultra"60-mil to 80-mil,fully adhered with hot roofing asphalt or mechanically fastened. 13.Deck:C-15/32 Incline:1 Existing Roof System:—Class A,B or C insulated or non-Insulated BUR cap sheet or modified bitumen system to retain the existing Classification covered with: Barrier Board(Optional):—One or more layers Georgia-Pacific Gypsum LLC"DensDeck®Roofboard"or"DensDeck®Prime Roofboard"or"DensDeck® DuraGuard"Roofboard",minimum'/4-in.thick,or United States Gypsum Co."SECUROCK®Roof Board"(Type FRX-G)or"SECUROCK®Glass-Mat Roof Board" (Type SGMRX),minimum 1/4-In.thick. Insulation(Optional):—Polyisocyanurate or wood fiber or perlite or glass fiber,any thickness,fully adhered with hot roofing asphalt or mechanically fastened. Cover Board:—Va-in.thick"EnergyGuard"HD"or V2-in.thick"EnergyGuard"HD Plus"or 1/2-in.thick"EnergyGuard"RH HD"or' -in.thick high-density wood fiber-board or one ply"VersaShield@ Fire-Resistant Roof Deck Protection",mechanically fastened. Slip Sheet(Optional):—One ply"StormSafe"",mechanically fastened. Membrane:—"EverGuard®Freedom"TPO"45-mil to 80-mil,self-adhered. 14.Deck:C-15/32 Incline:11 Existing Roof System:—Class A,B or C insulated or non-Insulated BUR cap sheet or modified bitumen system to retain the existing Classification covered with: Barrier Board(Optional):—One or more layers Georgia-Pacific Gypsum LLC"DensDeck®Roofboard"or"DensDeck®Prime Roofboard"or"DensDeck® DuraGuard•"Roofboard",minimum y4-in.thick,or United States Gypsum Co."SECUROCK®Roof Board"(Type FRX-G)or"SECUROCK®Glass-Mat Roof Board" (Type SGMRX),minimum 1/4-in.thick. Insulation(Optional):—Polyisocyanurate or wood fiber or perlite or glass fiber,any thickness,fully adhered with hot roofing asphalt or mechanically fastened. Cover Board:—' -in.thick"EnergyGuard"HD"or'h-in.thick"EnergyGuard"HD Plus"or 1-in.thick"EnergyGuard"RH HD"or 1-in.thick high-density wood fiber-board or one ply"VersaShield@ Fire-Resistant Roof Deck Protection",mechanically fastened. Slip Sheet(Optional):—One ply"StormSafe"",mechanicaly fastened. Base Sheet:—One ply"Liberty"SBS Self Adhering Base/Ply Sheet"or"RUBEROID@ SA Base/Ply Sheet",self-adhered. Membrane:—"RUBEROID®Torch Plus Granule FR"or"RUBEROID®HW Plus Granule FR"or"RUBEROID@ HW Granule FR"or'"RUBEROID®EnergyCap"HW Plus Granule FR"or"RUBEROID@ HW Plus Granule"or"RUBEROID®HW Granule"or"RUBEROID@ EnergyCapr'Torch Plus Granule FR",fully adhered with hot roofing asphalt. 15.Deck:C-15/32 Incline:2 Existing Roof System:—Class A,B or C insulated or noninsulated BUR cap sheet system to retain the existing Classification covered with: Slip Sheet:—One ply 6-oz./yd.2 polyester mat,loose laid. Membrane:—"EverGuard®TPO"60-mil to 80-mil or"EverGuard Extreme@ TPO"60-mil to 80-mil,mechanically fastened. 16.Deck:C-15/32 Incline:11/2,see Note 1 Existing Roof System:—Any Class A,B or C built-up roof system. Slip Sheet:—One or more plies"VersaShield@ Sob•"Fire Resistant Slipsheet",mechanicaly fastened or loose laid. Roof Covering:—Any BUR system or CPE,CSM,CSPE,EPDM,NBP,PIB,PVC,TPO or TRE polymeric single ply membrane system. Note 1:Classification(A,B or C)and maximum incline will be the same as that of the Classified Roofing System(TGFU)currently limited to noncombustible deck, but not to exceed inclines greater than 11/2:12. 17.Deleted. 18.Deleted. 19.Deck:NC Incline:1/2 Existing Roof System:—Class A,B or C insulated or non-insulated roof covering system(for gravel surfaced BUR systems,loose gravel may be removed)to retain the Class A,B or C rating covered with: Insuakion:—"EnergyGuard""or"EnergyGuard"Ultra"or"EnergyGuard"RF"or"EnergyGuard"RA"or"EnergyGuard"RN"or"EnergyGuard"RH"or "EnergyGuard"RM"or wood fiber or glass fiber or perlite,any thickness,mechanically fastened. Membrane:—"EverGuard®TPO"45-mil to 80-mil or"EverGuard Extreme®TPO"50-mil to 80-mil,mechanically fastened. Class B 1.Deleted. 2.Deleted. 3.Deleted. 4.Deleted. 5.Deleted. 6.Deleted. 7.Deleted. 8.Deck:C-15/32 Incline:3/4 Existing Roof System:—Class A,B or C system to retain the existing Classification covered with: Membrane:—"EverGuard®TPO FB Ultra"60-mi to 80-mil or"EverGuard Extreme®TPO FB Ultra"60-mil to 80-mil,fully adhered with hot roofing asphalt or mechanically fastened. FLUID APPLIED COATING SYSTEMS Class A 1.Deck:NC Incline:Unlimited Base Coat:—"TOPCOAT Gray"or"TOPCOAT White"or"TOPCOAT Membrane"applied at a rate of 1 to 1.5-gal./100-R.2. Intermediate Coat(Optional):—"TOPCOAT Gray"or"TOPCOAT White"or"TOPCOAT Membrane"applied at a rate of 1 to 1.5-gal./100-ft.2. 3R of 39 7/14/2016 10:34 AT •TGFU.R1306-Roofing Systems http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/sho... Top Coat:—"TOPCOAT Gray"or"TOPCOAT White"or"TOPCOAT Membrane"applied at a rate of 1 to 1.5-gal./100-ft.2. 2.Deck:NC Incline:No limitations Top Coat:—"TOPCOAT White"or"TOPCOAT Gray"or"TOPCOAT Membrane"applied at a rate of 2 to 3-gal./100-ft.2. SPRAY APPLIED FOAM AND COATING SYSTEMS Unless otherwise indicated,the deck surface may be primed with UL Classified asphalt emulsion. MAINTENANCE AND REPAIR SYSTEMS Class A,B or C 1.Deck:C-15/32 Incline:See Note 1 Existing Roof System:—Any Class A,B or C UL Classified EPDM,TPO,Hypalon,PVC,TPA,or CPE single ply membrane system,mechanically fastened or fully adhered,non-insulated or insulated,to retain existing Classification. Surfacing:—'TOPCOAT@ Silicone HS Elastomeric Coating"applied at 11h-gaV100-ft2. Note 1:Classification(A,B or C)and maximum incline will be the same as that of the Classified Roofing System(TGFU). Last Undated on 2016-05-03 Questions? Print this oaoe Terms of Use Page Too ©2016 UL LLC The appearance of a company's name or product in this database does not in itself assure that products so Identified have been manufactured under UL's Follow-Up Service.Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up Service.Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions:1.The Guide Information, Assemblies,Constructions,Designs,Systems,and/or Certifications(files)must be presented in their entirety and in a non-misleading manner,without any manipulation of the data(or drawings).2.The statement"Reprinted from the Online Certifications Directory with permission from UL"must appear adjacent to the extracted material.In addition,the reprinted material must include a copyright notice In the following format:"©2016 UL LLC". 10 of 10 7/14/9(116 f i n•1a AM