Report Fire Protection Services Inc. 5573 SW Arctic Cir. Beaverton, Oregon 97005 Phone: (503)590-3732 mo Fax: (503)628-6214 AEROTECH 9020 SW Washington Square Rd. 0 sw Tigard Oregon Suite #400 FIRE ALARM DESCRIPTION DESCRIPTION Relocate 2 horn/Strobes adding one to fire system Monitoring is provided through Alarm Central Station,a U.L.listed monitoring company (503.641.6761) All installation will be done according to N.F.P.A. 72 standard. Work will be performed in a neat and professional manner. All work will be performed according to the timeline set. All equipment will be UL listed and approved for the application. SYSTEM COMPONENTS Gentex Commander Series horn strobes/Strobes GENTEX CORPORATION Commander3 Series Selectable GEC3/GES3 Candela Evacuation Signals 12 & 24 VDC Applications The Commander3 Series is a low profile strobe and horn/strobe combination SERIES that offers dependable audible and visual alarms and the absolute lowest current available. The GE3 Series 24VDC offers tamperproof field selectable candela options of �. 15, 30, 60, 75, and 110 candela. The 12VDC offers tamperproof field �1 ' : = u. r;= selectable candela options of 15, 30, 60, and 75 candela. The Commander3 Series horn offers a continuous or synchable temporal three in 2400Hz and mechanical tone, a chime and whoop tone. All tones are easy i t for the professional to change in the field by the use of switches. The GE3 Series has a minimal operating current and has a minimum flash rate of 1 Hz regardless of input voltage. Product Listings The Commander3 Series is shipped with a standard 4" metal mounting plate SIGNAUNG which incorporates the popular Super-Slide®feature that allows the installer to ;� •;� easily test for supervision.The product also features a locking mechanism ULCY, . which secures the product to the bracket without any screws showing. m The Commander3 also features the patented Checkmate®- Instant Voltage LISTED 1 jI Verification feature which allows the installer to check the voltage drop draw • ANSWL 464&ANSI/UL 1971 Listed and match it to the blueprint. • CSFM: 7135-0569:122(GEC3-24& The GE3 Series appliances are ANSI/UL 464 and ANSI/UL 1971, listed for use GEH-24) with fire protective systems and are warranted for three years from date of 7125-0569:123(GES3-24) purchase. 7125-0569:129(GES3-12) 7135-0569:130(GEC3-12& Standard Features GEH-12) • MEA: 285-91-E(GEC3-24&GES3-24) • Nominal voltage 12VDC and 24VDC 580-06-E(GEC3-12&GES3-12) • 24VDC units have field selectable candela options of 15,30, 60, 75& 110 • 12VDC units have field selectable candela options of 15, 30, 60&75 Patents • GEH horn is available in 12VDC or 24VDC • 7,375,617 May 20,2008 • Unit Dimensions:5"(12.7 cm) high x 4.5"(11.43 cm)wide x 2.5"(6.35 cm) deep Product Compliance • Super-Slide®Bracket- Ease of Supervision Testing • NFPA 72 • Checkmate®-Instant Voltage Verification • Americans with Disabilities Act(ADA) • Synchronize strobe and/or horn with Gentex AVSM Control Module • IBC/IFC/IRC • Prewire entire system, install mounting bracket, then install signals • Quality Management System is certified • Documented lower installation and operating costs to:ISO 9001:2008 • Input terminals accept 12 to 18 AWG • Switch selection for high or low dBA • Switch for chime,whoop, mechanical and 2400Hz tone MEMBER • Tamperproof re-entrant style grill • Switch for continuous or temporal 3 tone (not available on whoop tone) ASSEMBLED IN • Surface mount with the GSB (Gentex Surface Mount Box) THE USA • Silence audible while visual appliance will remain flashing (for use in accepted jurisdictions) • Faceplate available in red or off-white GEH 12VDC or 24VDC Low Profile Evacuation Horn Model Number Part Number Nominal Voltage Reverberant dBA at In Anechoic Room 10ft.,per ANSWL 464 dBA at 10ft. GEH12-R 904-1239-002 12VDC 62-82 100 ' GEH12-W 904-1241-002 12VDC 62-82 100 GEH24-R 904-1205-002 24VDC 62-82 100 GEH24-W 904-1207-002 24VDC 62-82 100 GES3 12VDC or 24VDC Selectable Candela, Low Profile Evacuation Strobe Model Number Part Number Nominal Voltage Candela (ANSWL 1971) GES3-12WR 904-1235-002 12 VDC 15,30,60,75 GES3-12WW 904-1237-002 12 VDC 15,30, 60,75 GES3-24WR 904-1321-002 - 24 VDC 15,30,60,75, 110 GES3-24WW 904-1319-002 24 VDC 15,30,60,75, 110 GEC3 12VDC or 24VDC Selectable Candela, Low Profile Evacuation Horn/Strobe Model Number Part Number Nominal Voltage Candela Reverberant dBA at In Anechoic Room (ANSWL 1971) 10ft.,perANSWL 464 dBA at 10ft. GEC3-12WR 904-1231-002 12 VDC 15,30,60,75 62-82 100 GEC3-12WW 904-1233-002 12 VDC 15,30,60,75 62-82 100 GEC3-24WR 904-1317-002 24 VDC 15,30,60,75, 110 62-82 100 GEC3-24WW 904-1315-002 24 VDC 15,30,60,75, 110 62-82 100 GE3 Product Strobe Current Ratings (mA) Model Designations: 12 VDC(&17.5 Volts) 24 VDC(16-33 Volts) W=Wall mount Candela 12VDC UL Max' 24VDC UL Max' R = Red Faceplate W=White Faceplate 15cd 106mA 92mA 30mA 42mA Ocd 131mA 141 mA 35mA 58mA All units are available in plain (no lettering). Plain units are non-returnable. .0cd 186mA 260mA 66mA 97mA 5cd 237mA 312mA 80mA 116mA ALERT bezel available for order AGENT bezel available for order 110cdt :AltR ' 103mA 161 mA GE3-12 Product Horn Current Ratings GE3-24 Product Horn Current Ratings Horn Decibel Levels Horn Current Ratings Horn Decibel Levels Horn Current Ratings Minimum SPL Minimum SPL Minimum SPL Minimum SPL Regulated 12VDC Horn Mode ated 24VDC at 10R,per at 10ft.,per Mau.Operating 0 Horn Mode et 10R,per at 10ft.,per max.0 ting 0 Reg ANSWL 464 ANSWL 464 High Setting(mA) High 464 ANSI/UL 464 High(mA) (HIGH) (LOW) (HIGH) (LOW) Temp 3 2400Hz 76 dBA 69*dBA 29mA Temp 3 2400Hz 78 dBA 71*dBA 28mA Temp 3 Mechanical 75 dBA 68*dBA 26mA Temp 3 Mechanical 76 dBA 70*dBA 25mA Temp 3 Chime 62*dBA 60*dBA 13mA Temp 3 Chime 70*dBA 66*dBA 15mA Continuous 2400Hz 79 dBA 74*dBA 29mA Continuous 2400Hz 81 dBA 74*dBA 28mA Continuous Mechanical 78 dBA 72*dBA 26mA Continuous Mechanical 80 dBA 72*dBA 25mA Continuous Chime 63*dBA 61*dBA 13mA Continuous Chime 70*dBA 66*dBA 15mA Whoop 78 dBA 71*dBA 55mA Whoop 82 dBA 69*dBA 56mA NOTES: • Operating temperature:32°to 120°F(0°to 49°C). The GEC3 and GES3 Series is not listed for outdoor use. • For nominal and peak current across ANSI/UL regulated voltage range for filtered DC power and unfiltered(FWR[Full Wave Rectified])power,see installation manual. 12VDC models are DC only. • Gentex does not recommend using a coded or pulsing signaling circuit with any of our strobe products(see Technical Bulletin Number 014). • The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating. While the horn is producing a tone in the temporal 3 mode its sound pressure is the same as the continuous mode. • Operating the horn in this mode at this voltage will result in not meeting the minimum ANSI/UL 464 reverberant sound level required for public mode fire protection service. These settings are acceptable only for private mode fire alarm use. Use the high dBA setting for public mode application(not applicable when using the chime tone.The chime tone is always private mode). 1 RMS current ratings are per ANSI/UL average RMS method. ANSI/UL max current rating is the maximum RMS current within the listed voltage range(16-33VDC for 24VDC units)(8-17VDC for 12VDC units). For strobes the UL max current is usually at the minimum listed voltage(16VDC for 24VDC units)(8VDC for 12VDC units). For audibles the max current is usually at the maximum listed voltage. For unfiltered FWR ratings,see installation manual. Tone Switch Locations TONE SWITCH POSITION 3 4 5 rs Mechanical Temporal3 ON ON ON f1111 .110:= Mechanical-Continuous OFF ON ON CENT■ ■. D 2400Hz-Temporal 3 ON OFF ON 2400Hz-Continuous OFF OFF ON [w■ ■■ Chime-Temporal 3 ON ON OFF1=E�■ M. � I �=r \ Chime-Continuous OFF ON OFF Whoop ON OFF OFF C[0■ ■■ 01F" Whoop OFF OFF OFF Vl NOTE: ��® 1� >_� • Switch Positions 1 and 2 in the OFF position to Al select isolated horn and strobe power inputs 0*— • Switch Position 6 ON=HIGH dBA • Switch Position 6 OFF=LOW dBA III Gentex Super-Slide® Gentex Checkmate® Instant Mounting Bracket % Voltage Verification Allows the installer to pre-wire It is often necessary to confirm the the system,test for system voltage drop along a line of devices.The supervision, remove the signal ill 1, access holes are provided in the back of head until occupancy, switch yr the terminal block to allow the voltage to out Gentex signals without - Ili I be measured directly without removing the changing mounting brackets device.Typically this would be done at the and has locking edge connector 1111ili f` end of the line to confirm design criteria. for snap-in-place installation. l Most measurements will be taken using 1` the S+and S-locations although access ` is provided to other locations. • � ''� NOTE:Care should be taken to not short ��`�-s i0. the test probes. / Candela selection slider switch. Depress center fir"'' .� � and slide switch to desire , .`• ""�''� `� � 'brightness level. r lo �' ,i Nk.--- o------000—11 oi Break off pin and insert yII t`� 3 III into hole at the bottom of !. ,ii::60 yi it the selector to lock f15 , `` 1i IL ;f� 110 MODEL 1 I candela setting. Signal �• SELECT ON I'( :' r 0110 yg `, MARKER , y J must be removed from !j•- ii1I1I'tE. � � ■'bracket and pin pushed �� ',..1 , ��?i ( iI _ fOrliri-,----..,... -1)c. Tforward from backside out it __ __ �M,�t — of hole to change �� ' f�f candela. �J 1.000114)____......---' To remove bezel, grip both sides of bezel and pull in a downward and outward motion. Conventional Wiring Diagrams for Emergency Notification Evacuation Series UL Listed UL Listed Control Signal Slpnaf ControlPanel S+ S. 5- Ha H- S+ S. 8- Ha H- Panel Signal signal S+ S+ S- H+ H- S+ S+ S- H+ H- Supervised o S S S ,SMS Si nal Circuit 11.1111111_,111111111111 Supervised 9 ® 0 �" B 0 9\ © ' " NEafaTOR Signal Circuit ENDov L97E \ END OF UNE O RESISTOR \ Q END IS tME RESISTOR 0 NOTES: • All strobes are designed to flash as specified with continuous applied voltage. Strobes should not be used on coded or pulsing signaling circuits. However, use of the Gentex AVSM control module or Gentex synchronization protocol is permitted to synchronize the strobe, horn and/or mute the horn. See Technical Bulletin 014 for additional information. • FOR SYNCHRONIZATION WIRING INFORMATION,REFERENCE AVSM CONTROL MODULE DATA SHEET(551-0031) AND/OR AVSM CONTROL MODULE MANUAL(550-0284)FOR SYNCHRONIZATION MODULE WIRING DIAGRAMS. AVSM CONTROL MODULE DATA SHEET AND MANUAL CAN BE OBTAINED AT http://www.gentex.com OR CALL GENTEX CORPORATION AT 1-800-436-8391. • When synchronizing the GE3 12VDC Series,the Gentex AVSM control module or Gentex synchronization protocol MUST be used. Architect & Engineering Specifications The audible and/or visible signal shall be Gentex GEH,GESS,GEC3 Series or approved equal and shall be listed by Underwriters Laboratories, Inc.per ANSI/UL 1971 and/or ANSI/UL 464.The notification appliance shall also be listed with Factory Mutual Listing Service(FM)and the California State Fire Marshal(CSFM). The notification appliance(combination audible/visible)shall produce a peak sound output of 100dBA or greater at 12VDC or 24VDC as measured in an anechoic chamber.The signaling appliance shall also have the capability to silence the audible signal while leaving the visible signal energized with the use of a single pair of power wires.Additionally,the user shall be able to select either continuous or temporal tone output with the temporal signal having the ability to be synchronized. Unit shall be capable of being installed so that any unauthorized attempt to change the candela setting will result in a trouble signal at the fire alarm control panel. The audible/visible and visible signaling appliance shall also maintain a minimum flash rate of 1 Hz or up to 2Hz regardless of power input voltage. The strobe appliance shall have an operating current of 42mA or less at 24VDC for the 15Cd strobe circuit and 92mA or less at 12VDC for the 15Cd strobe circuit. The appliance shall be polarized to allow for electrical supervision of the system wiring.The unit shall be provided with a mounting bracket with terminals and barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox without the use of an adapter plate.The unit shall have an input voltage range of 16-33 volts with either direct current or full wave rectified power for 24VDC models or a voltage range of 8-17.5 volts for 12VDC models. The appliance shall be capable of testing supervision without disconnecting wires,verify voltage without removing unit and be capable of mounting to a surface back box. 24 units per carton 28 pounds per carton Important Notice: 551-0050-06 G E IV T E X These materials have been prepared by Gentex Corporation("Gentex")for informational purposes only,are necessarily summary,and are not purported to serve as legal advice and should not be used as such. Gentex makes no representations and warranties,express or implied,that these materials are complete and CORPORATION accurate,up-to-date,or in compliance with all relevant local,state and federal laws,regulations and rules. The materials do not address all legal considerations as there is inevitable uncertainty regarding interpretation of laws,regulations and rules and the application of such laws,regulations and rules to Fire Protection Products Group•www.gentex.com particular fact patterns.Each person's activities can differenty affect the obligations that exist under applicable laws,regulations or rules.Therefore,these materials should be used only for informational 10985 Chicago Drive •Zeeland, Michigan 49464 purposes and should not be used as a substitute for seeking professional legal advice.Gentex will not be responsible for any action or failure to act in reliance upon the information contained in this material. 616.392.7195 • 1.800.436.8391 •616.392.4219 Fax Gentex Corporation reserves the right to make changes to the product data sheet at their discretion.