Loading...
Plans Product Data /' .„------' ,...„ ____ Single Packaged Convertible ................ '......._...._______' ' --- ...-s- 7 - ,s, E, is, Gas/Electric 14 SEER 2-5 Ton 4YCC4024A1060A - 4YCC4030A1070A 4YCC4036A1070A 4YCC4036A1090A % Av 4YCC4042A1060A ..11����' �i 00,1»1 ii,1)) 4YCC4042A1090A _ i' 4YCC4048A1070A \'\ W I IIiø. ,, December 2014 22-1901-1 B-EN TO Ingersoll Rand 9 TRANE' Product Specifications MODEL 4YCC4024A1060A 4YCC4030A1070A 4YCC4036A1070A 4YCC4036A1090A Motor—HP/R.P.M. 1/34/3350 1/34/3290 1/34/3290 1/34/3075 Volts/Ph/Hz 230/1/60 230/1/60 250/1/60 230/1/60 FLA .20 .20 .20 .24 FILTER/FURNISHED NO NO NO NO Type Recommended THROWAWAY THROWAWAY THROWAWAY THROWAWAY Recmd.Face Area(sq ft)(h) 4.0 4.0 4.0 4.0 tREAUGERANT R4;0 '.. 11410 R�41Q R-410 Charge(lbs.) 5.24 6.94 7.2 7.2 CHA1tGING EC FCA XON 12° 11°l 11° 11° � Subcooling1/2 1/2 tASPIPSIE { ) 1/2 1/2 ' H3'X1�I Xt'> W H, DXW HXOXW 1~iItiCEN61E1N6 � R� - •,'- 46X45X52 46 X45 X52 48X45X52 Crated(in.) 48 X 45 X 52 4531379 Shipping(lbs.)/Net(lbs.) 432/358 451/377 438/374 (a) Rated in accordance with AHRI Standard 210/240.AHRI standard rating conditions are:80 D.B.67 W.B.entering air to indoor coil.95 D.B.entering air to outdoor coil. (b) Sound Power values are not adjusted for AHRI 270-95 tonal corrections. (a) Ratings shown are for elevations up to 2000 ft.For higher elevations reduce ratings at a rate of 4%per 1000 ft.elevation. (d) Convertible to LPG. (e) This value is approximate.For more precise value,see Unit Nameplate. (f) Standard Air—Dry Coil—Outdoor. (9) Based on U.S.Government Standard Tests. (h) Filters must be installed in return air stream.Square footages listed are based on 300 f.p.m.face velocity.If permanent filters are used size per manufacturer's recommendation with a clean resistance of 0.05"W.C. MODEL 4YCC4042A1060A 4YCC4042A1090A 4YCC4048A1070A' RATED Volts/PH/Hz 208-230/1/60 208-230/1/60 208-230/1/60 Performance Cooling BTUH(a) 40500 40500 46500 Indoor Airflow(CFM) 1450 1450 1600 Power Input(KW) 3.4 3.4 4.06 EER/SEER(BTU/Watt-Hr) 12.0/14.00 12.0/14.00 11.50/14.00 Sound Power Rating[dB(A)](b) 74.6 74.6 72.5 PERFORMANCE HEATING(c) Input BTUH-istStage 60000 90000 70000 (Natural Gas)(d) 81 81 AFUE 81 Temp.Rise—Min/Max(°F) 30/60 35/65 30/60 Orifice Qty/ Drill Sz.(Natural Gas) 2/#37 3/#37 2/#33 POWER CONN.—V/Ph/Hz 208-230/1/60 208-230/1/60 208-230/1/60 Min.Brch.Cir.Ampacity(e) 28.5 28.5 32.0 45 45 50 Fuse Size—Max.(amps) Fuse Size—Recmd.(amps) 45 45 50 COMPRESSOR SCROLL SCROLL SCROLL VOLTS/PH/HZ 208-230/1/60 208-230/1/60 208-230/1/60 R.L.Amps—L.R.Amps 16.7/109.0 16.7/109.0 19.6/130.0 OUTDOOR COIL—TYPE SPINE-FIN SPINE-FIN SPINE-FIN Rows/F.P.I 2/24 2/24 2/24 Face Area(sq.ft.) 15.63 15.63 20.54 Tube Size(in.) 3/8 3/8 3/8 INDOOR COIL—TYPE MCHE MCHE MCHE Rows/F.P.I 2/16 2/16 2/16 7 22-1901-1 B-EN 9 TRIINE° Product Specifications MODEL 4YCC4042A1060A 4YCC4042A1090A 4YCC4048A1070A Face Area(sq.ft,) 3.9 3.9 3.9 Tube Size Width(in.) .81 .81 .81 Refrigeration Control EXPANSION VALVE EXPANSION VALVE EXPANSION VALVE Drain Conn.Size(in.) 3/4 FEMALE NPT 3/4 FEMALE NPT 3/4 FEMALE NPT OUTDOOR FAN-TYPE SWEPT SWEPT SWEPT DIA.(IN.) 28.25 28.25 28.25 DRIVE/NO.SPEEDS DIRECT/1 DIRECT/1 DIRECT/1 CFM @ 0.0 in.w.g.(f) 3400 3400 4800 Motor-HP/R.P.M 1/4/825 1/4/825 1/4/825 Volts/Ph/Hz 208-230/1/60 208-230/1/60 208-230/1/60 F.L.Amps/L.R Amps 1.51/3.07 1.51/3.07 1.51/3.07 INDOOR FAN-TYPE CONSTANT TORQUE ECM CONSTANT TORQUE ECM CONSTANT TORQUE ECM Dia.x Width(in.) 10.62 X 10.62 10.62 X 10.62 10.62 X 10.62 Drive/No.Speeds DIRECT/3 DIRECT/3 DIRECT/3 CFM @ 0.0 in.w.g,(s) SEE FAN PERF TABLE SEE FAN PERF TABLE SEE FAN PERF TABLE Motor-HP/R.P.M. 3/4/1050 3/4/1050 3/4/1050 Volts/Ph/Hz 208-230/1/60 208-230/1/60 208-230/1/60 F.L.Amps 6 6 6 COMBUSTION FAN-TYPE CENTRIFUGAL CENTRIFUGAL CENTRIFUGAL Drive/No.Speeds DIRECT/1 DIRECT/1 DIRECT/1 Motor-HP/R.P.M. 1/34/3345 1/34/3075 1/34/3290 Volts/Ph/Hz 230/1/60 230/1/60 230/1/60 FLA .20 .24 .20 FILTER/FURNISHED NO NO Type Recommended NO THROWAWAY THROWAWAY THROWAWAY Recmd.Face Area(sq.ft)(h) 5.3 5.3 5.3 REFRIGERANT �t-410 N 410 fT# 0 Charge(lbs.) 7 3 7.3 CHARGING�SPE SPECIFICATIONS - �,. :� ' 7.5 Subcooling F-° . 10° 10° 10° GAS PXPE SIZE{in.} - , '' 1/2 1/2 1/2 DIMENSIONS HX0 ,1Al HXI7 W Crated(in.) ti x[?]fW 46 X47 X62 46 X47 X62 50 X47 X62 WEIGHT Shipping(lbs.)/Net(lbs.) 555/452 561/457 552/448 (a) Rated in accordance with AHRI Standard 210/240.AHRI standard rating conditions are:80 D.B 67 W.B.entering air to indoor coil.95 D.B.entering air to outdoor coil. (b) Sound Power values are not adjusted for AHRI 270-95 tonal corrections. (c) Ratings shown are for elevations up to 2000 ft.For higher elevations reduce ratings at a rate of 4%per 1000 ft.elevation. (d) Convertible to LPG. (e) This value is approximate.For more precise value,see Unit Nameplate. (f) Standard Air-Dry Coil-Outdoor. (e) Based on U.S.Government Standard Tests. (h) Filters must be installed in return air stream.Square footages listed are based on 300 f.p.m.face velocity.If permanent filters are used size per manufacturer's recommendation with a clean resistance of 0.05"W.C. MODEL 4YCC4048A1090A 4YCC4060A1090A 4YCC4060A1115A RATED Volts/PH/Hz 208-230/1/60 208-230/1/60 208-230/1/60 Performance Cooling BTUH(0) 46500 58000 58000 Indoor Airflow(CFM) 1600 1760 1760 Power Input(KW) 4.09 4.94 4.94 8 22-1901-1B-EN 0 TRANE° Product Specifications MODEL 4YCC4048A1090A 4YCC4060A1090A 4YCC4060A1115A EER/SEER(BTU/Watt-Hr.) 11.50/14.00 11.50/14.00 11.50/14.00 Sound Power Rating[dB(A)](b) 72.5 73.1 73.1 PERFORMANCE HEATING{cS InputBTUH-1st Stage 90000 90000 115000 (Natural Gas)(co 81 AFUE 81 81 30/60 30/60 Temp.Rise-Min/Max(°F) 35/653/#33 Orifice Qty/Drill Sz.(Natural Gas) 3/#37 3/#37 POWER CONN.-V/Ph/Hz 208-230/1/60 208-230/1/60 208-230/1/60 Min.Brch.Cir.Ampacity(e) 32.0 39.1 39.1 Fuse Size-Max.(amps) 50 60 60 Fuse Size-Recmd.(amps) 50 60 60 COMPRESSORSCROLL SCROLL SCROLL VOLTS/PH/HZ 208-230/1/60 208-230/1/60 208-230/1/60 R.L.Amps-L.R.Amps 19.6/130.0 24.4/144.2 24.4/144.2 OUTDOOR COIL-TYPE SPINE-FINS SPINE-FIN SPINE-FIN 2/24 Rows/F.P.I 2/24 2/24 22.99 22.99 Face Area(sq.ft.) 20.543/8 Tube Size(in.) 3/8 3/8 PLATE FIN " INDOOR COIL-TYPE MCHE PLATE FIN Rows/F.P.I 2/16 4/15 4/15 5.0 5.0 Face Area(sq.ft.) 3.93/8 Tube Size Width(in.) .81 3/8 EXPANSION VALVE EXPANSION VALVE EXPANSION VALVE Refrigeration Control 3/4 FEMALE NPT Drain Conn.Size(in.) 3/4 FEMALE NPT 3/4 FEMALE NPT SWEPT SWEPT OUTDOOR FAN-TYPE SWEPT28.25 DIA.(IN.) 28.25 28.25 DRIVE/NO.SPEEDS DIRECT/1 DIRECT/1 DIRECT/1 4800 4800 CFM @ 0.0 in.w.g.(f) 4800 1/3/825 Motor-HP/R.P.M 1/4/825 1/3/825 208-230/1/60 208-230/1/60 208-230/1/60 Volts/Ph/Hz 1.7/3.5 F.L.Amps/L.R Amps 1.51/3.07 1.7/3.5 INDOOR FAN-TYPE CONSTANT TORQUE ECM CON STANTTORQUE''ECM CONSTANT TORQUE ECM X 10.62 11.87 X 10.68 11.87 X 10.68 Dia.x Width(in.) 10.62 DIRECT/3 Drive/No.Speeds DIRECT/3 DIRECT/3 CFM @ 0.0 in.w.g.(9) SEE FAN PERF TABLE SEE FAN PERF TABLE SEE FAN PERF TABLE Motor-HP/R.P.M. 3/4/1050 1/1050 Volts/Ph/Hz 208-230/1/60 208-230/1/60 208-230/1/60 F.L.Amps 6 6.9 6.9 COMBUSTION FANS TYPE CENTRIFUGAL CENTRIFUGAL CENTRIFUGAL ' DIRECT/1 Drive/No.Speeds DIRECT/1 DIRECT/1 1/34/3075 1/34/3075 1/34/3055 Motor-HP/R.P.M. 230/1/60 Volts/Ph/Hz 230/1/60 230/1/60 FLA .24 .24 .25 FILTER/FURNISHED NO NO NO Type Recommended THROWAWAY THROWAWAY THROWAWAY Recmd.Face Area(sq.ft)(h) 5.3 5.3 5.3 E'.-410 `R 410 8-410 ���R �E�AN'r m. , w _e , e ., _ 9 22-1901-1 B-EN TRANE° Product Specifications MODEL 4YCC4O48A1O9OA 4YCC406OA1O9OA 4YCC4O6OA1115A Charge(lbs.) 7.5 9.65 9.65 CHARGING SPECIFICATIONS Subcooling 10° 11° 11° GAS PIPESI.ZE(in.) 1/2 1/2 1/2 Dfl4ENSIONS IIXD w H X DX W` : 11)(p X W Crated(in.) 50 X47 X62 50X47X62 50 X47 X62 Shipping(lbs.)/Net(lbs.) 557/453 580/476 586/482 (a) Rated in accordance with AHRI Standard 210/240.AHRI standard rating conditions are:80 D.B.67 W.B.entering air to indoor coil.95 D.B.entering air to outdoor coil. (b) Sound Power values are not adjusted for AHRI 270-95 tonal corrections. () Ratings shown are for elevations up to 2000 ft.For higher elevations reduce ratings ata rate of 4%per 1000 ft.elevation. (d) Convertible to LPG. (e) This value is approximate.For more precise value,see Unit Nameplate. (f) Standard Air—Dry Coil—Outdoor. (e) based on U.S.Government Standard Tests. (h) Filters must be installed in return air stream.Square footages listed are based on 300 f.p.m.face velocity.If permanent filters are used size per manufacturer's recommendation with a clean resistance of 0.05"W.C. 10 22-1901-1 B-EN 0 TRINE Outline Drawings Figure 13. 4YCC4042-4060 1487 17 - 157.37 1589/161 16-3(161 C 1 11.56 i INLET 115/321 (DUCT FLANGE) r111/1161 7.1/18 61 1$ N2, NT [II X•X SECTION �� TYPICAL(81 SIDES OF SIDEFLON DUCT OPENINGS � \ {(1/1I1I1I1//■/('lI / ���I\ 1125.22 INLET x[11/1'11'1/1'1111 �,`IhI1111�1 il.') INLET I iB11iiv 1 40111" 1— 11-5,161 1 1111 lbl 18.03 18.29 W����\`‘ . /•/��� / HOOD 123132] 123112] .\\�\� %//� f /\ w / '` r 1.22 19116] 201.81 [7-15/161 .(E FTIDN Y•Y TYPICAL(81 SIDES OF DOIINFLON DUCT OPENINGS INLET TOP SIDE ENTER OF GRAVITY 4 OUTLET ------1- =- A • I 11111 551 25 . . 13 OR FRONT SIDE [1110 121 23/321 19O.0E 13/11 FEMALENSATE DRAIN F NPT LEFT SIDE RECOMMENDED SERVICE CLEARANCE NM/IN. ■. i. WITH 0.4.DAMPER/ECON O BACK SIDE 301.8 1121 762.0(301 O .- -- LEFT SIDE 911.1 1361 1066.8 1121 • 1 RIGHT SIDE 911.11361 - _- -- -- _-� FRONT SIDE 1066.8 1121 - CLEARANCE TO COMBUSTIBLE MATERIAL NM/IN Y Y BOTTOM 0 t BACK SIDE 25.1 III LEFT SIDE 152.1161 -- --_-- _-- -- --- RIGHT SIDE 301.8 1121 Note:The view labeled FRONT SIDE 301.8 1121 "Bottom Side"represents the base as viewed looking TOP 911.1(361 up from underneath the unit. 9OTTOM SIDE 30 22-1901-1 B-EN 9 TRANE• Outline Drawings Figure 14. 4YCC4042-4060 z 372.82 [14-11/16] o f1mil • 100o (OUTSIDE) aU _ L..- 6.,......... ...._ \ • _ _ 58.19 ���`� // [2-9/32] / RETURN ��322.84 SUPPLY [12 23/32] ....----449.02 [17-11/16] 79.50 -.... (OUTSIDE) [3-1/8] 449.02 ;8 176.07 [17-11/16] [6-15/16] (OUTSIDE) BACK DUCT OPENINGS -r- . . --- - - 530.60 • [20-7/8] X x J ! L. l I. .� • . . . . . . ,., 1402.34 [55-7/32] (SURFACE AREA) BACK SIDE Height mm/in Approx.Corner Weight-kg/lbs Shipping Total Unit Center of Gravity mm/in Model Weight Weight A W1 W2 W3 W4 kg/lbs kg/lbs B C 4YCC4042(060) 898.53[35-3/8] 71.2[157] 46.6[103] 34.6[76] 53.1[117] 252.2[555] 202.0[452] 470.0[18.5] 731.0[28.8] 4YCC4042(090) 898.53[35-3/8] 71.8[158] 47.2[104] 35.2[78] 53.6[118] 254.5[561] 207.3[457] 470.0[18.5] 731.0[28.8] 4YCC4048(070) 1000.13[39-3/8] 71.4[157] 44.6[98] 33.2[73] 53.9[119] 250.3[552] 202.1[448] 433.0[17.0] 743.3[29.3] 4YCC4048(090) 1000.13[39-3/8] 72.0[159] 45.0[99] 33.8[75] 54.4[120] 252.6[557] 205.4[453] 433.0[17.0] 743.3[29.3] 4YCC4060(090) 1000.13[39-3/8] 77.1[170] 45.8[101] 34.4[76] 58.3[128] 263.1[580] 215.9[476] 433.0[17.0] 743.3[29.3] 4YCC4060(115) 1000.13[39-3/8] 78.0[172] 46.3[102] 34.9[77] 59.0[130] 265.8[586] 218.6[482] 414.0[16.3] 635.0[25.0] 22-1901-1 B-EN 81 YCC048—SF-1A Library Service Literature SERVICE Product Section Unitary Product Rooftop Air Conditioning Model YCC FACTS Literature Type Service Facts Sequence 1A Contains wiring and service information Date November 1989 File No. SV-UN-RT-YCC048-SF-1A 11/89 Supersedes New Models:YCCO48A1LOBA,SHOBA Gas/Electric Rooftop IMPORTANT-- This Document is customer property and is to remain with this unit.Please return to service information pack upon completion of work. PRODUCT SPECIFICATIONS OPTIONAL EQUIPMENT MODEL YCC048A1 MODEL YCC048A1 Model/Comp Description RATED VOLTS/PH/HZ 208-230/1/60 OUTDOOR FAN(Cont./ AY28X092 Thermostat-Heat/Cool A.R.I.RATINGS(COOLING)' Type Drive/No.Speeds Direct/1 BAYCCHT001 Crankcase Heater Kit BTUH 48.0 No.Motors—HP 1-.33 BAYCURB024A Roof Mounting Curb Indoor Air Flow(CFM) 1600 Motor Speed R.P.M. 1090 BAYCURB032A Single Roof Curb System Power(KW) 5.64 Volts/Ph/Hz 208-230/1/60 BAYDMPRO32A 0-25%Manual Outside Air EER/SEER 1BTU/Watt-Hr.) 8.2/9.1 F.L.Amps—L.R.Amps 2.4-5.0 BAYECON045A Downflow Economizer • Noise Rating No. 8.0 INDOOR FAN—Type Centrifugal BAYFLTRO1 IA Permanent Filter Accessory BAYGARD001 Coil Guard Dia.x Width(In.) 9.031 x 8 - RATINGS(HEATINGI' BAYHAKT007 High Alt Conversion Kit Input BTUH 100000 No.Used 1 BAYKSKT009A Quick Start Kit Capacity BTUH' 74000 Drive/Speeds(No.) Direct/2 BAYLPKTO1 OA LP Gas Conversion Kit Temp.Rise—Min./Max.F 40/80 No.Motors—HP 1-.33 BAYLPKT01 1 A LP Gas Conversion Kit Type of Gas' Natural Motor Speed R.P.M. 1075 BAYSTAT003 Night Setback Voltsi Ph/Hz 208-230/1/60 POWER CONNS.—V/Ph/Hz 208-230/1/60 F.L.Amps—L.R.Amps 4.0-6.6 BAYSTAT004 Prog Nite Setback w/o Econ Min.Brch.Cir.Ampacity 39 BAYSTAT008 Man Changeover w/o Econ Fuse Size—Max.(Amps) 60 COMBUSTION FAN—Type Centrifugal BAYSTAT010 2H/2C Auto Chgover No.Used 1 BAYSTAT012 Manual Chgovr w/Econ COMPRESSOR Copeland No.Used 1 Drive—Speeds INo.) Direct-1 BAYSTAT305 Heat/Cool Vertical Volts/Ph/Hz 208-230/1/60 Motor HP—Speed(RPM) .02-3000 Pp/Hz 208-230/1/60 R.L.Amps—L.R.Amps 27-114 F F.L.Amps 42 AWARNING OUTDOOR COIL—Type Plate Fin FILTER—Furnished? No Rows/F.P.I. 2;16 Type Recommended Disposable Face Area(Sq.Ft.) 7.29 No.of Filters Used 2 Tube Size(In.) 376 Filter Size 16 x 25 x1 SAFETY NOTICE INDOOR COIL—Type Plate Fin REFRIGERANT THIS INFORMATION IS INTENDED FOR USE BY INDI- Rows/F.P.I. 2/15 Charge(Lbs.of R-22)' 5.0 VIDUALS POSSESSING ADEQUATE BACKGROUNDS Face Area(Sq.Ft.) 4.58OF ELECTRICAL AND MECHANICAL EXPERIENCE. Tube Size(In.) ,375 GAS PIPE SIZE IIn.) .75 ANY ATTEMPT TO REPAIR A CENTRAL AIR CONDI-• Refrigerant Control Capillary DIMENSIONS H x W x D TIONING PRODUCT MAY RESULT IN PERSONAL MANU- DrainfriConn.Size y,"NPTrCrated(In.) 34.0x Wx 49.0 INJURY AND/OR PROPERTY DAMAGE.THE FACTURER OR SELLER CANNOT BE RESPONSIBLE Duct Connections See Outline Drawing Uncrated See Outline Drawing FOR THE INTERPRETATION OF THIS INFORMATION, OUTDOOR FAN—Type Propeller WEIGHT NOR CAN IT ASSUME ANY LIABILITY IN CONNEC- No.Used/Dia.(In.) 1/20 Shipping(Lbs.)/NetiLbs.) 539/499 TION WITHI/T'S�USE. CapacityPI. t rateddr in rating with A.R.I.D.B.67 W.B.21Noiseratedindoor coil. A.R.I.inStandard to outdoor Si/ AUTION A.R.I.Standard rating conditions ares 80 D.B.67 .B.entering air to indoor coil:95 D.B.entering air to outdoor v coil. 'Ali models are American Gas Association Certified.Limit settings and rating data were established and approved under laboratory test conditions using American National Standards Institute Standards.Ratings shown are for RECONNECT ALL GROUNDING DEVICES elevations up to 2000 feet.For elevations above 2000 feet,ratings should be reduced at the rate of 4%for each 1000 feet above sea level. ALL PARTS OF THIS PRODUCT CAPABLE OF CON- Convertible Convertible to LPG with orifice change. DUCTING ELECTRICAL CURRENT ARE GROUNDED. IF GROUNDING WIRES, SCREWS, STRAPS, CLIPS, 'This value is approximate.For more precise value;see unit nameplate and service instructions. NUTS OR WASHERS USED TO COMPLETE A PATH TO 'Based on U.S.Government Standard tests. GROUND ARE REMOVED FOR SERVICE,THEY MUST BE RETURNED TO THEIR ORIGINAL POSITION AND PROPERLY FASTENED. NOTICE:Since the manufacturer has a policy of continuous product improvement, DA N G E R it reserves the right to change specifications and design without notice. il DISCONNECT POWER BEFORE SERVICING Page G-418-152 No 10 screw each corner of HVAC HVAC unit through 24ga . strap U \ IT 2 " screw into 24ga . strap IV through roof curo �� Insulate ° roof euro 8" Lacg oolts 3 " lonc into 2 " x6 " 24 " aTong roof curo ( 4 ) per sloe