Plans Product Data /'
.„------'
,...„
____
Single Packaged Convertible
................ '......._...._______' ' --- ...-s- 7 - ,s, E, is,
Gas/Electric 14 SEER
2-5 Ton
4YCC4024A1060A -
4YCC4030A1070A
4YCC4036A1070A
4YCC4036A1090A % Av
4YCC4042A1060A ..11����' �i 00,1»1 ii,1))
4YCC4042A1090A _ i'
4YCC4048A1070A \'\
W I
IIiø.
,,
December 2014 22-1901-1 B-EN TO Ingersoll Rand
9 TRANE'
Product Specifications
MODEL 4YCC4024A1060A 4YCC4030A1070A 4YCC4036A1070A 4YCC4036A1090A
Motor—HP/R.P.M.
1/34/3350 1/34/3290 1/34/3290 1/34/3075
Volts/Ph/Hz
230/1/60 230/1/60 250/1/60 230/1/60
FLA .20
.20 .20 .24
FILTER/FURNISHED NO NO NO NO
Type Recommended THROWAWAY THROWAWAY THROWAWAY THROWAWAY
Recmd.Face Area(sq ft)(h) 4.0 4.0 4.0 4.0
tREAUGERANT R4;0 '.. 11410 R�41Q R-410
Charge(lbs.)
5.24 6.94 7.2 7.2
CHA1tGING
EC FCA XON 12° 11°l
11° 11°
�
Subcooling1/2 1/2
tASPIPSIE { ) 1/2 1/2
' H3'X1�I Xt'> W H, DXW
HXOXW
1~iItiCEN61E1N6 � R� - •,'-
46X45X52
46 X45 X52 48X45X52
Crated(in.) 48 X 45 X 52
4531379
Shipping(lbs.)/Net(lbs.)
432/358 451/377 438/374
(a) Rated in accordance with AHRI Standard 210/240.AHRI standard rating conditions are:80 D.B.67 W.B.entering air to indoor coil.95 D.B.entering air to
outdoor coil.
(b) Sound Power values are not adjusted for AHRI 270-95 tonal corrections.
(a) Ratings shown are for elevations up to 2000 ft.For higher elevations reduce ratings at a rate of 4%per 1000 ft.elevation.
(d) Convertible to LPG.
(e) This value is approximate.For more precise value,see Unit Nameplate.
(f) Standard Air—Dry Coil—Outdoor.
(9) Based on U.S.Government Standard Tests.
(h) Filters must be installed in return air stream.Square footages listed are based on 300 f.p.m.face velocity.If permanent filters are used size per
manufacturer's recommendation with a clean resistance of 0.05"W.C.
MODEL 4YCC4042A1060A 4YCC4042A1090A 4YCC4048A1070A'
RATED Volts/PH/Hz
208-230/1/60 208-230/1/60 208-230/1/60
Performance Cooling BTUH(a) 40500
40500 46500
Indoor Airflow(CFM)
1450 1450 1600
Power Input(KW) 3.4 3.4 4.06
EER/SEER(BTU/Watt-Hr)
12.0/14.00 12.0/14.00 11.50/14.00
Sound Power Rating[dB(A)](b) 74.6 74.6 72.5
PERFORMANCE HEATING(c)
Input BTUH-istStage 60000 90000 70000
(Natural Gas)(d) 81 81
AFUE 81
Temp.Rise—Min/Max(°F) 30/60
35/65 30/60
Orifice Qty/
Drill Sz.(Natural Gas) 2/#37 3/#37 2/#33
POWER CONN.—V/Ph/Hz 208-230/1/60 208-230/1/60 208-230/1/60
Min.Brch.Cir.Ampacity(e) 28.5 28.5 32.0
45 45 50
Fuse Size—Max.(amps)
Fuse Size—Recmd.(amps) 45 45 50
COMPRESSOR
SCROLL SCROLL SCROLL
VOLTS/PH/HZ 208-230/1/60 208-230/1/60 208-230/1/60
R.L.Amps—L.R.Amps
16.7/109.0 16.7/109.0 19.6/130.0
OUTDOOR COIL—TYPE
SPINE-FIN SPINE-FIN SPINE-FIN
Rows/F.P.I
2/24 2/24 2/24
Face Area(sq.ft.) 15.63 15.63 20.54
Tube Size(in.)
3/8 3/8 3/8
INDOOR COIL—TYPE MCHE MCHE MCHE
Rows/F.P.I 2/16 2/16 2/16
7
22-1901-1 B-EN
9 TRIINE°
Product Specifications
MODEL 4YCC4042A1060A 4YCC4042A1090A 4YCC4048A1070A
Face Area(sq.ft,) 3.9 3.9
3.9
Tube Size Width(in.) .81 .81
.81
Refrigeration Control EXPANSION VALVE
EXPANSION VALVE EXPANSION VALVE
Drain Conn.Size(in.) 3/4 FEMALE NPT 3/4 FEMALE NPT 3/4 FEMALE NPT
OUTDOOR FAN-TYPE SWEPT SWEPT
SWEPT
DIA.(IN.) 28.25 28.25
28.25
DRIVE/NO.SPEEDS DIRECT/1 DIRECT/1
DIRECT/1
CFM @ 0.0 in.w.g.(f) 3400 3400
4800
Motor-HP/R.P.M 1/4/825 1/4/825 1/4/825
Volts/Ph/Hz 208-230/1/60 208-230/1/60 208-230/1/60
F.L.Amps/L.R Amps 1.51/3.07 1.51/3.07
1.51/3.07
INDOOR FAN-TYPE CONSTANT TORQUE ECM CONSTANT TORQUE ECM CONSTANT TORQUE ECM
Dia.x Width(in.) 10.62 X 10.62 10.62 X 10.62
10.62 X 10.62
Drive/No.Speeds DIRECT/3 DIRECT/3
DIRECT/3
CFM @ 0.0 in.w.g,(s) SEE FAN PERF TABLE SEE FAN PERF TABLE SEE FAN PERF TABLE
Motor-HP/R.P.M. 3/4/1050 3/4/1050 3/4/1050
Volts/Ph/Hz 208-230/1/60
208-230/1/60 208-230/1/60
F.L.Amps 6 6
6
COMBUSTION FAN-TYPE CENTRIFUGAL CENTRIFUGAL CENTRIFUGAL
Drive/No.Speeds DIRECT/1 DIRECT/1 DIRECT/1
Motor-HP/R.P.M. 1/34/3345 1/34/3075 1/34/3290
Volts/Ph/Hz 230/1/60 230/1/60 230/1/60
FLA .20 .24
.20
FILTER/FURNISHED NO NO
Type Recommended NO
THROWAWAY THROWAWAY THROWAWAY
Recmd.Face Area(sq.ft)(h) 5.3 5.3
5.3
REFRIGERANT �t-410 N 410 fT# 0
Charge(lbs.) 7 3
7.3
CHARGING�SPE SPECIFICATIONS - �,. :�
' 7.5
Subcooling F-° .
10° 10° 10°
GAS PXPE SIZE{in.} - , '' 1/2
1/2 1/2
DIMENSIONS
HX0 ,1Al HXI7 W
Crated(in.) ti x[?]fW
46 X47 X62 46 X47 X62 50 X47 X62
WEIGHT
Shipping(lbs.)/Net(lbs.) 555/452 561/457
552/448
(a) Rated in accordance with AHRI Standard 210/240.AHRI standard rating conditions are:80 D.B 67 W.B.entering air to indoor coil.95 D.B.entering air to
outdoor coil.
(b) Sound Power values are not adjusted for AHRI 270-95 tonal corrections.
(c) Ratings shown are for elevations up to 2000 ft.For higher elevations reduce ratings at a rate of 4%per 1000 ft.elevation.
(d) Convertible to LPG.
(e) This value is approximate.For more precise value,see Unit Nameplate.
(f) Standard Air-Dry Coil-Outdoor.
(e) Based on U.S.Government Standard Tests.
(h) Filters must be installed in return air stream.Square footages listed are based on 300 f.p.m.face velocity.If permanent filters are used size per
manufacturer's recommendation with a clean resistance of 0.05"W.C.
MODEL 4YCC4048A1090A 4YCC4060A1090A 4YCC4060A1115A
RATED Volts/PH/Hz 208-230/1/60 208-230/1/60
208-230/1/60
Performance Cooling BTUH(0) 46500 58000
58000
Indoor Airflow(CFM) 1600 1760
1760
Power Input(KW) 4.09
4.94 4.94
8
22-1901-1B-EN
0 TRANE°
Product Specifications
MODEL 4YCC4048A1090A 4YCC4060A1090A 4YCC4060A1115A
EER/SEER(BTU/Watt-Hr.)
11.50/14.00 11.50/14.00 11.50/14.00
Sound Power Rating[dB(A)](b) 72.5
73.1 73.1
PERFORMANCE HEATING{cS
InputBTUH-1st Stage 90000 90000 115000
(Natural Gas)(co 81
AFUE 81 81
30/60 30/60
Temp.Rise-Min/Max(°F) 35/653/#33
Orifice Qty/Drill Sz.(Natural Gas) 3/#37 3/#37
POWER CONN.-V/Ph/Hz
208-230/1/60 208-230/1/60 208-230/1/60
Min.Brch.Cir.Ampacity(e)
32.0 39.1 39.1
Fuse Size-Max.(amps)
50 60 60
Fuse Size-Recmd.(amps)
50 60 60
COMPRESSORSCROLL SCROLL SCROLL VOLTS/PH/HZ 208-230/1/60 208-230/1/60 208-230/1/60
R.L.Amps-L.R.Amps
19.6/130.0 24.4/144.2 24.4/144.2
OUTDOOR COIL-TYPE
SPINE-FINS SPINE-FIN SPINE-FIN
2/24
Rows/F.P.I
2/24 2/24
22.99 22.99
Face Area(sq.ft.) 20.543/8
Tube Size(in.) 3/8 3/8 PLATE FIN "
INDOOR COIL-TYPE MCHE PLATE FIN
Rows/F.P.I
2/16 4/15 4/15
5.0 5.0
Face Area(sq.ft.) 3.93/8
Tube Size Width(in.) .81 3/8
EXPANSION VALVE EXPANSION VALVE EXPANSION VALVE
Refrigeration Control 3/4 FEMALE NPT
Drain Conn.Size(in.) 3/4 FEMALE NPT 3/4 FEMALE NPT
SWEPT SWEPT OUTDOOR FAN-TYPE SWEPT28.25
DIA.(IN.) 28.25 28.25
DRIVE/NO.SPEEDS
DIRECT/1 DIRECT/1 DIRECT/1
4800 4800
CFM @ 0.0 in.w.g.(f) 4800 1/3/825
Motor-HP/R.P.M 1/4/825 1/3/825
208-230/1/60 208-230/1/60 208-230/1/60
Volts/Ph/Hz 1.7/3.5
F.L.Amps/L.R Amps 1.51/3.07 1.7/3.5
INDOOR FAN-TYPE CONSTANT TORQUE ECM CON STANTTORQUE''ECM CONSTANT TORQUE ECM
X 10.62 11.87 X 10.68 11.87 X 10.68
Dia.x Width(in.) 10.62 DIRECT/3
Drive/No.Speeds DIRECT/3 DIRECT/3
CFM @ 0.0 in.w.g.(9) SEE FAN PERF TABLE SEE FAN PERF TABLE SEE FAN PERF
TABLE
Motor-HP/R.P.M. 3/4/1050 1/1050
Volts/Ph/Hz
208-230/1/60 208-230/1/60 208-230/1/60
F.L.Amps
6 6.9 6.9
COMBUSTION FANS TYPE
CENTRIFUGAL CENTRIFUGAL CENTRIFUGAL
' DIRECT/1
Drive/No.Speeds DIRECT/1 DIRECT/1
1/34/3075 1/34/3075 1/34/3055
Motor-HP/R.P.M. 230/1/60
Volts/Ph/Hz 230/1/60 230/1/60
FLA
.24 .24 .25
FILTER/FURNISHED
NO NO NO
Type Recommended
THROWAWAY THROWAWAY THROWAWAY
Recmd.Face Area(sq.ft)(h) 5.3
5.3 5.3
E'.-410 `R 410 8-410
���R �E�AN'r m. , w _e , e ., _
9
22-1901-1 B-EN
TRANE°
Product Specifications
MODEL 4YCC4O48A1O9OA 4YCC406OA1O9OA 4YCC4O6OA1115A
Charge(lbs.) 7.5 9.65 9.65
CHARGING SPECIFICATIONS
Subcooling 10° 11° 11°
GAS PIPESI.ZE(in.) 1/2 1/2 1/2
Dfl4ENSIONS IIXD w H X DX W` : 11)(p X W
Crated(in.) 50 X47 X62 50X47X62 50 X47 X62
Shipping(lbs.)/Net(lbs.) 557/453 580/476 586/482
(a) Rated in accordance with AHRI Standard 210/240.AHRI standard rating conditions are:80 D.B.67 W.B.entering air to indoor coil.95 D.B.entering air to
outdoor coil.
(b) Sound Power values are not adjusted for AHRI 270-95 tonal corrections.
() Ratings shown are for elevations up to 2000 ft.For higher elevations reduce ratings ata rate of 4%per 1000 ft.elevation.
(d) Convertible to LPG.
(e) This value is approximate.For more precise value,see Unit Nameplate.
(f) Standard Air—Dry Coil—Outdoor.
(e) based on U.S.Government Standard Tests.
(h) Filters must be installed in return air stream.Square footages listed are based on 300 f.p.m.face velocity.If permanent filters are used size per
manufacturer's recommendation with a clean resistance of 0.05"W.C.
10 22-1901-1 B-EN
0 TRINE
Outline Drawings
Figure 13. 4YCC4042-4060
1487 17 - 157.37
1589/161 16-3(161
C 1
11.56 i INLET
115/321
(DUCT FLANGE)
r111/1161
7.1/18 61 1$ N2, NT
[II
X•X
SECTION ��
TYPICAL(81 SIDES OF SIDEFLON DUCT OPENINGS � \
{(1/1I1I1I1//■/('lI / ���I\
1125.22 INLET x[11/1'11'1/1'1111 �,`IhI1111�1 il.') INLET
I iB11iiv 1 40111"
1— 11-5,161 1 1111
lbl
18.03 18.29 W����\`‘ . /•/��� / HOOD
123132] 123112] .\\�\� %//� f
/\ w
/ '` r
1.22
19116] 201.81
[7-15/161
.(E FTIDN Y•Y
TYPICAL(81 SIDES OF DOIINFLON DUCT OPENINGS
INLET
TOP SIDE ENTER OF GRAVITY
4
OUTLET
------1- =-
A
•
I 11111
551
25 .
. 13 OR FRONT SIDE
[1110 121 23/321 19O.0E 13/11 FEMALENSATE DRAIN F NPT
LEFT SIDE
RECOMMENDED SERVICE CLEARANCE NM/IN. ■. i.
WITH 0.4.DAMPER/ECON O
BACK SIDE 301.8 1121 762.0(301 O .- --
LEFT SIDE 911.1 1361 1066.8 1121 • 1
RIGHT SIDE 911.11361 - _- -- -- _-�
FRONT SIDE 1066.8 1121 -
CLEARANCE TO COMBUSTIBLE MATERIAL NM/IN Y Y
BOTTOM 0 t
BACK SIDE 25.1 III
LEFT SIDE 152.1161 -- --_-- _-- -- ---
RIGHT SIDE 301.8 1121 Note:The view labeled
FRONT SIDE 301.8 1121 "Bottom Side"represents
the base as viewed looking
TOP 911.1(361 up from underneath the unit. 9OTTOM SIDE
30 22-1901-1 B-EN
9 TRANE•
Outline Drawings
Figure 14. 4YCC4042-4060
z
372.82
[14-11/16]
o f1mil
• 100o (OUTSIDE)
aU
_ L..- 6.,......... ...._
\ • _ _ 58.19
���`� // [2-9/32]
/ RETURN ��322.84
SUPPLY [12 23/32]
....----449.02
[17-11/16]
79.50 -.... (OUTSIDE)
[3-1/8]
449.02 ;8
176.07
[17-11/16] [6-15/16]
(OUTSIDE)
BACK DUCT OPENINGS
-r- . .
--- - -
530.60
• [20-7/8]
X x
J ! L. l I.
.� •
. . . . . . ,.,
1402.34
[55-7/32]
(SURFACE AREA)
BACK SIDE
Height mm/in Approx.Corner Weight-kg/lbs Shipping Total Unit Center of Gravity mm/in
Model Weight Weight
A W1 W2 W3 W4 kg/lbs kg/lbs B C
4YCC4042(060) 898.53[35-3/8] 71.2[157] 46.6[103] 34.6[76] 53.1[117] 252.2[555] 202.0[452] 470.0[18.5] 731.0[28.8]
4YCC4042(090) 898.53[35-3/8] 71.8[158] 47.2[104] 35.2[78] 53.6[118] 254.5[561] 207.3[457] 470.0[18.5] 731.0[28.8]
4YCC4048(070) 1000.13[39-3/8] 71.4[157] 44.6[98] 33.2[73] 53.9[119] 250.3[552] 202.1[448] 433.0[17.0] 743.3[29.3]
4YCC4048(090) 1000.13[39-3/8] 72.0[159] 45.0[99] 33.8[75] 54.4[120] 252.6[557] 205.4[453] 433.0[17.0] 743.3[29.3]
4YCC4060(090) 1000.13[39-3/8] 77.1[170] 45.8[101] 34.4[76] 58.3[128] 263.1[580] 215.9[476] 433.0[17.0] 743.3[29.3]
4YCC4060(115) 1000.13[39-3/8] 78.0[172] 46.3[102] 34.9[77] 59.0[130] 265.8[586] 218.6[482] 414.0[16.3] 635.0[25.0]
22-1901-1 B-EN 81
YCC048—SF-1A
Library Service Literature
SERVICE Product Section Unitary
Product Rooftop Air Conditioning
Model YCC
FACTS Literature Type Service Facts
Sequence 1A
Contains wiring and service information Date November 1989
File No. SV-UN-RT-YCC048-SF-1A 11/89
Supersedes New
Models:YCCO48A1LOBA,SHOBA Gas/Electric Rooftop
IMPORTANT-- This Document is customer property and is to remain with this unit.Please return to service information pack upon
completion of work.
PRODUCT SPECIFICATIONS OPTIONAL EQUIPMENT
MODEL YCC048A1 MODEL YCC048A1 Model/Comp Description
RATED VOLTS/PH/HZ 208-230/1/60 OUTDOOR FAN(Cont./ AY28X092 Thermostat-Heat/Cool
A.R.I.RATINGS(COOLING)' Type Drive/No.Speeds Direct/1 BAYCCHT001 Crankcase Heater Kit
BTUH 48.0 No.Motors—HP 1-.33 BAYCURB024A Roof Mounting Curb
Indoor Air Flow(CFM) 1600 Motor Speed R.P.M. 1090 BAYCURB032A Single Roof Curb
System Power(KW) 5.64 Volts/Ph/Hz 208-230/1/60 BAYDMPRO32A 0-25%Manual Outside Air
EER/SEER 1BTU/Watt-Hr.) 8.2/9.1 F.L.Amps—L.R.Amps 2.4-5.0 BAYECON045A Downflow Economizer
•
Noise Rating No. 8.0 INDOOR FAN—Type Centrifugal BAYFLTRO1 IA Permanent Filter Accessory
BAYGARD001 Coil Guard
Dia.x Width(In.) 9.031 x 8
- RATINGS(HEATINGI' BAYHAKT007 High Alt Conversion Kit
Input BTUH 100000 No.Used 1 BAYKSKT009A Quick Start Kit
Capacity BTUH' 74000 Drive/Speeds(No.) Direct/2 BAYLPKTO1 OA LP Gas Conversion Kit
Temp.Rise—Min./Max.F 40/80 No.Motors—HP 1-.33 BAYLPKT01 1 A LP Gas Conversion Kit
Type of Gas' Natural Motor Speed R.P.M. 1075 BAYSTAT003 Night Setback
Voltsi Ph/Hz 208-230/1/60
POWER CONNS.—V/Ph/Hz 208-230/1/60 F.L.Amps—L.R.Amps 4.0-6.6 BAYSTAT004 Prog Nite Setback w/o Econ
Min.Brch.Cir.Ampacity 39 BAYSTAT008 Man Changeover w/o Econ
Fuse Size—Max.(Amps) 60 COMBUSTION FAN—Type Centrifugal BAYSTAT010 2H/2C Auto Chgover
No.Used 1 BAYSTAT012 Manual Chgovr w/Econ
COMPRESSOR Copeland
No.Used 1 Drive—Speeds INo.) Direct-1 BAYSTAT305 Heat/Cool Vertical
Volts/Ph/Hz 208-230/1/60 Motor HP—Speed(RPM) .02-3000
Pp/Hz 208-230/1/60
R.L.Amps—L.R.Amps 27-114 F F.L.Amps 42 AWARNING
OUTDOOR COIL—Type Plate Fin FILTER—Furnished? No
Rows/F.P.I. 2;16 Type Recommended Disposable
Face Area(Sq.Ft.) 7.29 No.of Filters Used 2
Tube Size(In.) 376 Filter Size 16 x 25 x1 SAFETY NOTICE
INDOOR COIL—Type Plate Fin REFRIGERANT THIS INFORMATION IS INTENDED FOR USE BY INDI-
Rows/F.P.I. 2/15 Charge(Lbs.of R-22)' 5.0 VIDUALS POSSESSING ADEQUATE BACKGROUNDS
Face Area(Sq.Ft.) 4.58OF ELECTRICAL AND MECHANICAL EXPERIENCE.
Tube Size(In.) ,375 GAS PIPE SIZE IIn.) .75 ANY ATTEMPT TO REPAIR A CENTRAL AIR CONDI-•
Refrigerant Control Capillary DIMENSIONS H x W x D TIONING PRODUCT MAY RESULT IN PERSONAL
MANU-
DrainfriConn.Size y,"NPTrCrated(In.) 34.0x Wx 49.0 INJURY AND/OR PROPERTY DAMAGE.THE FACTURER OR SELLER CANNOT BE RESPONSIBLE
Duct Connections See Outline Drawing Uncrated See Outline Drawing FOR THE INTERPRETATION OF THIS INFORMATION,
OUTDOOR FAN—Type Propeller WEIGHT NOR CAN IT ASSUME ANY LIABILITY IN CONNEC-
No.Used/Dia.(In.) 1/20 Shipping(Lbs.)/NetiLbs.) 539/499 TION WITHI/T'S�USE.
CapacityPI. t rateddr in rating
with A.R.I.D.B.67 W.B.21Noiseratedindoor coil.
A.R.I.inStandard
to outdoor
Si/ AUTION
A.R.I.Standard rating conditions ares 80 D.B.67 .B.entering air to indoor coil:95 D.B.entering air to outdoor v
coil.
'Ali models are American Gas Association Certified.Limit settings and rating data were established and approved
under laboratory test conditions using American National Standards Institute Standards.Ratings shown are for RECONNECT ALL GROUNDING DEVICES
elevations up to 2000 feet.For elevations above 2000 feet,ratings should be reduced at the rate of 4%for each
1000 feet above sea level. ALL PARTS OF THIS PRODUCT CAPABLE OF CON-
Convertible Convertible to LPG with orifice change. DUCTING ELECTRICAL CURRENT ARE GROUNDED.
IF GROUNDING WIRES, SCREWS, STRAPS, CLIPS,
'This value is approximate.For more precise value;see unit nameplate and service instructions. NUTS OR WASHERS USED TO COMPLETE A PATH TO
'Based on U.S.Government Standard tests. GROUND ARE REMOVED FOR SERVICE,THEY MUST
BE RETURNED TO THEIR ORIGINAL POSITION AND
PROPERLY FASTENED.
NOTICE:Since the manufacturer has a policy of continuous product improvement, DA N G E R
it reserves the right to change specifications and design without notice. il
DISCONNECT
POWER BEFORE SERVICING
Page G-418-152
No 10 screw each corner of
HVAC HVAC unit through 24ga . strap
U \ IT
2 " screw into 24ga . strap
IV
through roof curo
�� Insulate ° roof euro
8" Lacg oolts 3 " lonc into 2 " x6 "
24 " aTong roof curo ( 4 ) per sloe