Loading...
Plans (82) t ( C---7v s 72-7 NEW UNIT CASING NEW UNIT BASE AND BASE RAIL SECURE ANCHOR TO UNIT WITH ' (4)#10 x 1/2'TEK SCREWS SECURE ANCHOR TO CURB W(TH(4)#10 x 1/2"TEK . SCREWS,TYPICAL(NEW) HMI MUM 1■■I INV� WOOD NAILER 16 GAUGE STEEL'CANFAB' num OR EQUAL ANCHOR,(4) nom mai TOTAL,(1)EACH CORNER ism • UNIT MOUNTING CURB BY UNIT ON LONG SIDES OF UNIT is;; MANUFACTURER(14"HEIGHT) 11,111 GALVANIZED SHEET METAL Ilii MINIMUM 2x P.T.LEVEL COUNTER FLASHING I::; PLATFORM BY CONTRACTOR ■■� JulJuEXISTING ROOF SHEATHING, l ROOFING BY OTHERS �•', REMOVE UNDER UNIT AS REQUIRED /' ►;, 7/ • SECURE CURB TO SUPPORT FRAMING WITH#14 WOOD SCREWS AT EACH CORNER AND AT 7-0"O.C. EXISTING SUPPORT MAXIMUM SPACING,SCREWS MUST BE LONG ENOUGH TO PENETRATE SUPPORT FRAMING 2"MINIMUM 1 HVAC CURB DETAIL S-4 1 1/2"=1'-0" 810AH00001 Project: -Untiitled1 11/21/2016 Prepared By: 12:05PM 810AHO0001 Tag Cover Sheet Unit Report Certified Drawing Performance Report Packaged Rooftop Builder 1.44 Page 1 of 8 ti Unit Report For 810AH00001 Project: —Untitled1 11/21/2016 Prepared By: 12:05PM . Unit Parameters Dimensions(ft.in.)&Weight(lb.)*** Unit Model- 48KCDA04A0A3-0A3D0 Unit Length- 6'2.375" Unit Size- 04(3 Tons) Unit Width- 3' 10.75" Volts-Phase-Hertz- 208-1-60 Unit Height 2'9.375" Heating Type- Gas *** Total Operating Weight- 560 lb Duct Cfg- Vertical Supply/Vertical Return Low Heat *** Weights and Dimensions are approximate. Weight does Sinle Stage Com ressor Models not include unit packaging. Approximate dimensions are g g p provided primarily for shipping purposes.For exact dimensions and weights,refer to appropriate product data catalog. Lines and Filters Return Air Filter Type- Throwaway Return Air Filter Quantity- 2 Return Air Filter Size- 16 x 25 x 2 Unit Configuration Standard Static Direct Drive-ECM Al/Cu-Al/Cu Base Electromechanical Controls Hinged Access Panels Thru-The-Base Connections Standard Packaging Warranty Information 1-Year parts(std.) 5-Year compressor parts(std.) 10-Year heat exchanger-Aluminized(std.) No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 48KCDA04A0A3-0A3D0 Rooftop Unit 1 Base Unit Hinged Access Panels Thru-The-Base Connections None Accessories CRTWOPOS010A00 Air Damper 1 CRPECONV003A00 Hinged Access Door 1 CRLVHLGD012A00 Louvered Condenser Coil Hail Guard 1 CPLOWAMB001A00 Motormaster II Low Ambient Control 1 CRWINSTR001A00 Winter Start Package 1 Packaged Rooftop Builder 1.44 Page 2 of 8 Certifirang fTctTUntitlededDwior8bOAHUOOOl1 Prepared By: 11!21/2016 1205PM NOTES: 1. DIMENSIONS ARE IM INCHES DINENS]OXS UNITED P.O.DOR 1210 THIS DOC WENT IS TM PIWERTI OF CAMEO CORP NATIOI SUWII90102 OF THESE PRAWNS 01 DOCWEM 0 TECHNOLOGIES STIACUSE,It IS ISL[YEIEI IWON ME E%MESS(J$9 q iMA7 THE DOES NOT 23221//111 PART PERFORMANCE 01 IN[ ] AAE IN N[LLINETE S. UNIT 3 8 (1 PHASE) K(3 PHASE) CARRIER 13221 Cgrelrtsau DOT11 D1SCLg1Oq USE1WIIHWTFAIDIEI 33 318 1/7/8 14 7/a CORPORATION'S NII TTEN CONSENT. ACCEPTANCE OF CONTRACT. 2. CENTER OF GRAVITY 48KC 04 [8411 [377] [3771 40,05 33 3/8 14 7/8 18 5/8 CONNECTION SIZES 3.01110,DIRECTION OF AIR FLOW 18471 13171 [4727 A 1 3/8' [35]DIA FIELD POWER SUPPLY HOLE 48KC 06 41 3/8 14 7/8 18 5/8 [1051] (3771 [4721 B 2' 1501 DIA POWER SUPPLY KNOCKOUT C 1 3/4' [51]DIA GAUGE ACCESS PLUG 33-3/8 D 7/8" [22]DIA FIELD CONTROL WIRING HOLE [8481 E 3/4"-14 NPT CONDENSATE DRAIN F 1/2"-14 NPT GAS CONNECTION G 2 1/2' 164]DIA POWER SUPPLY KNOCK-OUT 114 ECONOMIZER HOOD _ 32 [818] (OPTIONAL) 16 FILTER ACCESS PANEL• L1061 (TOOL-LESS) COMP ACCESS CONDENSER• •• - THRU-THE-BASE CHART PANEL COIL TNECRBTMPWR001A0f E HOLES REQUIRED INDOOR COIL ,���. _ I THREADED WIRE REO'D HOLE ACCESS PANEL I —�'� 1 CONDUIT SIZE USE SITES(MAX.) 1 _ ��� \ �- [652]8 ----.--. - 10-7/8 N 112" ACC. 7/8" 122.21 [2777 X 172" 240 7/6 122.27 �[1Ii1♦�1� RETURN AIR RETURN - —����I�1�'� 41 _ 1 A 3/4" (001,003) POWER 1 1/8" [28.4] [11171 • ��®����� •, „ AIR 2*. !�\�!/� 10031 1/2•FPT GAS 1 3/16" 130.01 BACK HANDLE 2-5/861 . 0 FOR"THRU-THE-BASEPAN' FACTORY OPTION, TYP ��/ FITTINGS FOR ONLY%,Y, 6 Z ARE PROVIDED E ALT, J CURB 4W • CONDENSATE - N SELECT EITHER 3/4"OR 1/2" WIDTH i •% DRAIN OPENING 1451] MO' FOR POWER, DEPENDING ON WIRE SIZE 18-1/8 1 IN BASEPAN SUPPLY 26-1/2 29-3/8 Ny (0011 PROVIDES 3/4 FPT THRU CURB [4591 AIR 16131 17/71 SUPPLY FLANGE d FITTING. IB-1/8 11-1/J 12-1/4 _ 1 AIR 1411] 13631 13127 I SEE THRU THE 6 6- /A f i i i y BASE CHART . •. .[IS74 T i J1 --- 12-1/8 -.—~ 3R3]8 25 —y LUE [3071il [851 K [6361 4 HOOD 41007 TOP ~ [4-1/2 4-s/a [1181 101/2 • ELECTRICAL _. [265] [3214 — ' DISCONNECT •• = LiEi1 II OCATION •` —� 1i:- CONDENSER COIL CONTROL BOX • INDOOR BLOWER ACCESS PANEL ACCESS E STD. I iI ILTER I —. _,_ f • CONDENSATE II* 72 r,„ J i DRAIN t I OPTIONAL � zs-Ira FACTORY ^— INSTALLED , f- 19-1/2 OPTIONAL—'=,+— 18-3/1 RETURN I 1 OUTSIDE CONYEN(EMCE 1-,=--- •�- fA8/] FACTORY F}�• ANDLE 11-3/8 I'. 14211 AIR OUTLET — I INSTALLED „� ,--H 12881 SUPPLY AIR L I — DISCONNECT . s / li AIR 8..� 8 [166] —...= x .. • • �.....— -, Q I II - 21 1// 539] .740 0 r Com. . 00Or 61551 ���RNNNN 3-3// !1557 s [95] HANDLE 6-5/8 7 46-3/4 -8-378 4 111811 30-178-- 82137 17641 (1691 [1117 1152] 74-3/8 26-1/A [18887 (6827 BAROMETRIC 31-T/4 RELIEF LEFT [1831 FLOW FRONT AIRPLY 4 t RETURN RIGHT AIR SHEET DATE S666111DES 48KC 04-06 SINGLE ZONE ELECTRICAL 1 OF 2 09-16-14 COOLING WITH GAS HEAT 48KC000281 REV Packaged Rooftop Builder 1.44 Page 3 of 8 Certified Drawing for $10AH00001 112016 /21/ Project: -Untitled1 Prepared By: /12:05PM /2016 UNITED P.O.541 1511 THIS OCCUIENT IS THE PROPERTY Of CHAFER CORPORATION SN6NISSION or 11151 MAIMS CO MOMENTS TECHNOLOGIES 51661601.AE ANDTFMTDEWILF51166 6EMOISCLESEO SS CONDITIOONURACAMRI EN DOES NOT CONSTITNTE PANT PENEO SONCE OR ACCEPTANCE R tdTRACi. CARRIER 13201 COIRORATION'S WRITTEN CONSENT. STD. UNIT CORNER CORNER CORNER CORNER C.6. HEIGHT UNIT WEIGHT WEIGHT(A) WEIGHT 181 WEIGHT(C) WEIGHT(D) Y Z LBS. KG. LBS. KG. LBS. N6. LBS. KG. LAS. KG. K 48KC 04 490 222 120 54 111 50 125 56 135 61 35 3/4[9081 24 3/4[628] 18 I/O[4791 48KC 05 544 246 130 58 126 57 142 64 146 66 36 3/4[9331 24 3/4[6281 18 7/8[4791 48KC 06 591 200 141 64 156 70 158 71 142 64 39 1/8 1993] 23 1/2 15971 20 1/8[511] STANDARD UNIT WEIGHT IS WITH LOW GAS HEAT AND WITHOUT PACKAGING FOR OTHER OPTIONS AND ACCESSORIES, REFER TO THE PRODUCT DATA CATALOG. CORNER ACORNER B -,1 1 0 tl Y I '1'"'���\®/, 111, I fly/ • CORNER D _ CORNER C z TOP • =--- =I= M9 1-1 2 11o0 `. i .. I : ooh FRONT 48KC 04-06 SINGLE ZONE ELECTRICAL NES SHEET OATF SNPENCF6FS 48K0000281 2 ort 09-16-14 - COOLING WITH GAS HEAT Page E Packaged Rooftop Builder 1.44 Certified Drawing for 810AH00001 Project: -Untitledl 11/21/2016 Prepared By: 12:05PM Service Clearance 11111110114k,////////fr1411111H er 008337 LOCATION DIMENSION CONDITION 48-in(1219 mm) •Unit disconnect is mounted on panel A 18-In(457 mm) •No&connect,convenience outlet option •Recommended service clearance 12-in(305 mm) •Minimum clearance 42-in(1067 mm) •Surface behind servicer is grounded(e.g.,metal,masonry wall) B 364n(914 mm) •Surface behind servicer is electrically non-conductive(e.g.,wood,fiberglass) Special •Check for sources of flue products within 10-ft.of unit fresh air intake hood 36-in(914 mm) •Side condensate drain is used 18-in(457 mm) •Minimum clearance 48-In(1219 mm) •No flue discharge accessory installed,surfacers combustible material 42-In(1067 mm) •Surface behind servicer is grounded(e.g.,metal,masonry wall,another writ) 0 36-in(914 mm) •Surface behind servicer is electrically non-conductive(e.g.,wood,fiberglass) Special •Check for adjacent units or building fresh air intakes within 10-ft.of this unit's flue outlet NOTE:Unit not designed to have overhead obstruction.Contact Application Engineering for guidance on any application planning overhead obstruction or vertical clearances. Omsk i-z Packaged Rooftop Builder 1.44 Page 5 of 8 Performance Summary For 810AH00001 Project: —Untitledl 11/21/2016 _ Prepared By: 12:05PM Part Number:48KCDA04A0A3-0A3D0 ARI SEER- 14.00 Base Unit Dimensions Unit Length- 74.4 in Unit Width' 46.8 in Unit Height- 33.4 in Operating Weight Base Unit Weight' 490 lb Hinged Access Panels- 5 lb Thru-The-Base Connections- 4 lb Accessories Air Damper 39 lb Louvered Condenser Coil Hail Guard' 16 lb Motormaster II Low Ambient Control' 5 lb Winter Start Package' 1 lb Total Operating Weight- 560 lb Unit Unit Voltage-Phase-Hertz- 208-1-60 Air Discharge' Vertical Fan Drive Type- Direct Actual Airflow- 1199 CFM _ Site Altitude' 39 ft Cooling Performance . Condenser Entering Air DB' 105.0 F Evaporator Entering Air DB- 88.8 F Evaporator Entering Air WB' 63.0 F Entering Air Enthalpy' 28.35 BTU/lb Evaporator Leaving Air DB' 60.9 F Evaporator Leaving Air WB' 52.5 F Evaporator Leaving Air Enthalpy' 21.66 BTU/lb Gross Cooling Capacity' 36.05 MBH Gross Sensible Capacity' 36.05 MBH Compressor Power Input- 3.28 kW Coil Bypass Factor 0.209 Mixed Air Outdoor Air Airflow 420 CFM Outdoor Air DB- 105.0 F Outdoor Air WB' 61.0 F Outdoor Air Htg.Temp: 22.0 F Return Air DB- 80.0 F Return Air WB' 64.0 F Return Air Htg.Temp' 70.0 F Heating Performance Heating Airflow 1199 CFM Entering Air Temp- 53.2 F Leaving Air Temp' 94.2 F Gas Heating Input Capacity' 65.0 MBH Gas Heating Output Capacity- 0.0153.0 MBH Temperature Rise' 41.0 F 81.0 Thermal Efficiency(%)' 82.0 Supply Fan Packaged Rooftop Builder 1.44 Page 6 of 8 Performance Summary For 810AH00001 Project: -Untitled1 11/21/2016 Prepared By: 12:05PM Detailed Acoustics Information Octave Band Center Freq.Hz 63 125 250 500 1k 2k 4k 8k Overall A 78.2 78.0 74.2 73.3 70.6 66.0 62.4 56.9 82.9 Lw B 52.0 61.9 65.6 70.1 70.6 67.2 63.4 55.8 75.4 LwA C 45.8 45.6 41.8 40.9 38.2 33.6 30.0 24.5 50.5 Lp D 19.6 29.5 33.2 37.7 38.2 34.8 31.0 23.4 43.0 LpA Legend A Sound Power Levels at Unit's Acoustic Center, Lw B A-Weighted Sound Power Levels at Unit's Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp D A-Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space,an Acoustical Engineer or a person with sound prediction expertise should be consulted. Packaged Rooftop Builder 1.44 Page 8 of 8 r' Performance Summary For 810AH00001 . Project: -Untitledl 11/21/2016 Prepared By: 12:05PM - External Static Pressure- 0.72 in wg Fan RPM- 1200 Fan Power 1.00 BHP Fan Motor Size,hp- 1 NOTE- Motor Speed Tap 4,Vert,Direct Drive Electrical Data Voltage Range- 187-253 Compressor#1 RLA- 16.6 Compressor#1 LRA- 79 Outdoor Fan Motor Qty- 1 Outdoor Fan FLA(ea)- 1 Indoor Fan Motor Type- Direct Drive Indoor Fan Motor FLA- 7.4 Combustion Fan Motor FLA(ea)- 0.48 Power Supply MCA- 30 Power Supply MOCP(Fuse or HACR). 45 Disconnect Size FLA- 29 Disconnect Size LRA. 88 Electrical Convenience Outlet- None Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage Acoustics A Weighted• 76.0 db Sound Power Levels,db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz NA NA 78.2 125 Hz NA NA 78.0 250 Hz NA NA 742 500 Hz NA NA 73.3 1000 Hz NA NA 70.6 2000 Hz NA NA 66.0 4000 Hz NA NA 62.4 8000 Hz NA NA 56.9 Advanced Acoustics ssss 0 ) ss . •amu I ..., \ --Sil . s. 0 i , r r Advanced Accoustics Parameters 1. Unit height above ground- 30.0 ft 2. Horizontal distance from unit to receiver 50.0 ft 3. Receiver height above ground- 5.7 ft ., 4. Height of obstruction- 0.0 ft 5. Horizontal distance from obstruction to receiver 0.0 ft 6. Horizontal distance from unit to obstruction- 0.0 ft Packaged Rooftop Builder 1.44 Page 7 of 8