Loading...
Permit (100) x CITY OF TIGARD MASTER PERMIT ' COMMUNITY DEVELOPMENT71 Permit#: MST2016-00580 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 01/30/2017 Parcel: 2S 106DB05000 Jurisdiction: Tigard Site address: 17303 SW GRANITA LN Subdivision: RIVER TERRACE NORTHWEST Lot: 50 Project: River Terrace Northwest, Lot 50 Project Description: New SF BUILDING Floor Areas Required Setbacks Required Stories: 2 Bedrooms: 4 First: 625 sf Basement: 0 sf Left: 3 Parking Spaces: 0 Height: 24 Bathrooms: 3 Second: 1017 sf Garage: 418 sf Front: 8 Smoke Dwelling Units: 1 Third: 0 sf Right: 3 Detectors: Yes Total: 1642 sf Value: $203,603.32 Rear: 0 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 4 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Storm Sewer: 100 Tubs/Showers: 2 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Drains: 0 Catch Basins: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 1 Backwater Value: 1 Bckflw Prevntr: 0 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 4 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 4 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'I 500 sf: 2 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: N Other Description: Ecompasing: Y BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SF VB R-3 1642 Owner: Contractor: ADLV LAND HOLDINGS LLC WILLIAM LYON HOMES INC Required Items and Reports(Conditions) BY FORSUM,MICHAEL 109 E 13TH STREET 1 Ersn Cntrl 503-639-4175 7600 E DOUBLETREE RANCH RD VANCOUVER,WA 98660 STE 1 SCOTTSDALE,AZ 85258 PHONE: PHONE: 360-695-7700 FAX: Total Fees: $30,045.00 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: / Permittee Signature: O ,r"G=1C -770 Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Bu><ld><n6 Permit APPlication rola OFFICE 1.51 001.E I 7,-; :---i {,��k G F';e. Received �� Pccm�t N FEB o 201 1� . , i. s1 ' 'l p}f/ c(� 14 •City of Tigard Plan Review ^� Q Otho Pam. I/ 9/`4, 190,, 223 13125 SW Hall Blvd.,Tigard.OR 97 I?atdBY 1 oL-�7-1 lig . �. R-., 'Jurix H SeePage2for Phone: 503.718.2439 Fax 503.598.196j��.�r Ut.. S ' ARD DazeReady/By: ��NI Suppiementat7nformahon Inspection ww. 503.639.4175 U tr��gNG D\/SlONN Method_/ 'z� /7 TIC;:;F l> �vww,tigard-0r.gov BUILDING /tr 4 Internet U?l�a / . { .� r ''. -- r' Permit fees*are based on the value of the work performed. --'2-----' s 0 Demolition Indicate the value(rounded to the nearest dollar)of all ®New constructionequipment,materials,labor,overhead,and the profit for the _ - work indicated on this application. ❑Addition/alteration/replacement ❑�� - iir. sr, 3 `�#®.,,...� : :i . ;4-f r ,.. .:- .a - M ' `/alUatlOII' S I '4116 0 Cominercial/mdustiial I ® 1 and 2 family dwelling Number of bedrooms: 0 Accessory building 0 Multi-family Number of bathrooms: 4,5,---- 0 Master Y'❑Master builder 0 Other -n - Total number of floors: 2 .Z GI ' 0 �* 3 . .-] _ --=. area: l .+ q feet _ i 1 eiI New dwellings uare Job site address: /73y.3 SGu �/ Garage/carport area �t square feet Suite/bldgJapt no.: project name: City/StatefGlY:Sherwood,OR 97140 � � � Covered porch area: 40 � square feet . Deck area: le square feet Cross street/directions to job site: Other structure area: ', square feet . Lot no.: 57 Permit fees*are based on the value of the work performed. Subdivision Indicate the value(rounded to the nearest a dollar)of all for the equipment,materials,labor,overhead, profit—T ..lication Tax map/parcel no � �� � work indicated on this • b- - ` J-:, F I� 'a -� .-1--127 � � --17=-•71 :7.'-'-- -,.- ®..,. 3....�:......�..�. �,.. Valuation: New Single Family Detached Construction Existing building area: square feet New building area: square feet .��,.� � . - _ �� � c:- Number of stories: �- : _ --=__,, — Name:Polygon WLType of construction H,LLC Occupancy groups: Address:109 E 136 Street Existing: City/StatefLll:Vancouver,WA 98660 Phone:(360)695 7700 Fax �93 4442 -y (360 �%"�-` -.-} :i7,,,---,v 'IF"-, 11,,..',.=,-;:-2--:" n...7:_ 4 :•.--.--,----._'---- u« .,-._ - . . �-....uc. � ,...�.. .... v name:Polygon LLC Structural plan review fee(or deposit): Business ygon WI$ 1111.111111 Contact name:Maggie Gordon FLS plan review fee(if applicable): IIIIIIIIIIII Address:109 E 136 Street Total fees due upon application : 11111111111111 City/State/'ZIP:Vancouver,WA 98660 Amount received : IIIIIIIIMI Fax::(360)693.4442 - Phone:(360)695.7700 - E-mail:maggie Bordon aQpolygonhomes corn Commercial and residential prescriptive installation„ f ° .�„ roof-top mounted Photovoltaic Solar Panel System- ,' Submit two(2)sets of roof plan with connection details Business name:Polygon WL$LLC and fire department access,along with the 2010 Oregon Solar Installation S• ial Code checklist. Address:109E 13th Street Permit Fee(includes plan review $180.00 Vancouver,WA 98660 and administrative fees : City/State/ZIP: Fax:(360)693.4442 State surcharge(12%of permit fee): $21_60 Phone:(360)695.7700 _ ___ $201:60 - Total fee due upon application: CCB lic.:207247 triol-is not obtained This permit applicationrexpires if a pe s oompletes Authorized signature: �Mr within 18od days after it has been accepted = *Fee methodology set by Tri-Couaty.B>�dmg�dustiy Date.1T/11/15 Service Board Print name:Maggie Gordon 4401t613T(11/02/COM/WEB) I I:\Building\PetmitslBUP RESPermitAPP-doc 02/24/2011 •' 1 Mechanical Permit Application City of Tigard ,,;t r Sy,i(1 ' �.jsd��� 13125 SW Bail Blvd.,Tigard,OR 972?3 FEBPears Review g Phone: 503.7181439 Fax: 503.598.1960; B 03 2016 Oaie,By Other Permit: t 7 Inspection Line: 503.&39.4175 Date Resdvlfiy: Vis: t ga See Page 2 for Internet: w'ww.tigard-0r.eov CITY OF # � `�� Noritiiedtklethod:: SuppiemeatalInformation -„ n Mechanical permit fees*are based on the value of the work to New construction 0 Addition/alteration/replacement performed.Indicate the value(rounded to the nearest dollar)of all ❑Demolition 0 Other: mechanical materials equipment.labor,overhead and profit. roValue S DD I—and 2-family dwelling 0 Commercial/industrial 0 Accessory building Farsperlat hilt:wino-kw use c*eeklisa [3 Multi-family 0 Master builder 0 Other. Description Qty. Ea. Total t > Heating/rooting: ... �� , _. _..,..... w . .. ., Air condi ionise 46.75 lob site address: 1 W ( t Furnace 100,000 BTU(ducts/vents) 46.75 City/State/ZIP: 6 Ni1 LD O (� ( I Furnace 100.000+BTU(d cnts) . 54.91 �-1 beat pump 61.06 Sttiteibldg./apt.no.: -1 Project name:Rizer Terrace Duct work 2132 Cross street/directions to job site: fiydronic hot water system _ 2332 Residential boiler(radiator or hydronic) 23.32 Unit heaters(fuel-type.not electric), in-wall,in-duct,suspended.etc. 46,75 r Flue/vent for any of above 2332 Subdivision:River Terrace I Lot no.: J 0 - Other: 23.32 Other rad applisnees: Tax map/parcel no.: Water heater 23.32 - t` Yt � , ,as.: 3+ . h Gas I I acenttsert 3339 . a .. .. . .�_ - « _ . .�R � s Flue vent for water heater or gas UV AC fireplace 2332 Log halter{,pas) 23.32 - _ ood/pelletstove.' 33.39 Wood fireplace/insert 23.32 , Chimneylliner/flue/vent 23.32 1 Other 2332 :e:'4,;-.*.."' .: ar.�k. w a .` ''''''Vi...k q -ova" ': u &.. ..... _ - .--. �- Environmental exhaust end vents tion: Name:PolygonRange hood/other kitchen t . - equipment . 33.39 Address:109 E 13°St.Suite 200 Clothes dryer exhaust 33.39 City/State/DP:Vsueouver,WA 98660 Single-duct exhaust(bathrooms, i toilet compartments,utility rooms) 23.32 Phone:(425)586-7700 Fax;( ) Attickrawispacefans 2332 ::4:-Zr' 0. . ° € li .,„.,,,;:,:arc:::,..,,,.,,,,,,,a Other 2332 Fuel P BttSiti s name:Apex Air LLC S14.15 far first four:34.03 for tacit additional Contact name:Staci Bay Furnace.etc. Gas treat pump I Address:2210 W.Main St.Suite 107-272 Wall/suspended/unit beater City/State/ZIP:Battle Ground,WA 98604 Water beater Phone:(360)342-8109 Fax:':(360)326-1769 Fireplace . - Rantre E-mail:staeilt{®apexaireo.Cam Barbecue t ... 0Nia* ,. ,f tt i s e Cloths dryer(gas) v • iVrh er Business name:Apex Air LLC .--t a i.-„, ' rr n a- u Address:220 W.Main St.Suite 107-272 Subtotal City/State/ZIP:Battle Ground,WA 98604 -,Minimum permit fee(590.00) Plan review(225%of pe€mii fee) I Phone:(.368)3424109 Fax::(360)326-1769 State surcharge(12%of permit fee) I t TOTA1,1'EltMIT , — [ CCB Iic.:203034 This permit opprtmetion spires if a permit is not obtained within 181) -"#/,' ' . . days after it has been acceptett as complete. Authorized signafurc� . Fee methodology: et by Tri Cooney Building Industry Service Board Date: i Print ratite:Staci hay 1 €'&t,5d:ne,Pcsmi&.MEC crmitApp ti4Ot€.3 doe -._ ... 440-46€7T4 t IKar04,4A'E F . ? t Electile 0CEI - ilicat , 1 Clt l<T I{ L l j T 13!25 SW Hill Slvd.,Ttgsrd,(}R 972 FEBCity of Tigard 0 3 2016 D.teJav P"nit d:f �Gf1/• ,''401 1 Pito=n 501 7182439 fax:'503.590.1960 Plan Review I1a(eJB ttalatcdPernuik- T1t5irli)-: lnspcalou Lures SR3.b39:4173,. a ,-y t'� :°t� ' adsnmin Ssalfs 2rac Internet wtmv.tiz d argav C e�" a t'- w.: ee '//� a .s !NG-1-")1‘1 t.10 La tvte�ad: $appleattdt0l tnFermn nnn PX4 Newconttruction OAddition/s#terat#oiifreplacturteat Ple;s6 chad;,utMai 11Fidrffbimt1,st"otFlans wiftainss dceaj:. [�i)etnolAiwt L Qther Movie*or eedar40a amps 01 01015 0 Detlding ovarlbree;torhe. Etk/ wham thravo'kbla fault cement ❑Matioitt amdboatyards ,-T c rtcoww,"oF t, ,;A tea"ttcl,"nOtd ' -: _ exeeet&Ikeda amp*at 150 volts or 0 Roatmgbiutdirigs. e3 1-and 2-family dwelling Q ComsnerclaWuidusirial Q Aeccssoty building 1=1°gm-udd orei l i 42 It ' Plumbing Permit Applicatiof i) Building Fixtures City of Tigard N 0 V 3 Z016 ReceivedDate/BPermit Na41J '/F'G(,ScO IN, 13125 SW Hall Blvd.,Tigard,OR 97223 I,, , i Rtl. Other Permit Na:: Phone: 503.718.2439 Fax.503.594.1196K k i. t. Deale Inspection Line: 503.639 4175 r , , Date ReadyBy lurk la See Page 2 for Son lemental laformalion I i� 1 Interact WWW dga�'Or-g0'N �t��I('i�' t� ,� C ' 1 Noh6edlMetlmd: y� .: _ e • - 0 Demolition .For special hrforsrafion use ch ��4 New t onshuctton Description I Qty. I Ea. I Total 0 Addition/alteration/replacement 0 Other New 1-2-family dwellings(includes 100 ft for each utility connection) rr. j° . -1 ,.. SFE()bath 312.70 : ::::.4.4 ,... SFR(2)bath 437.78 ►off 1-and 2-family dwelling • CornmerciaVuulnstrial SFR(3) 500.32 ❑Accessory building ❑Multi-family Each additional bath/kitchen 25.02 ❑Master builder ❑Other: Fire sprinkler L_sq.ft.) Page 2 ' c�. . ,-~ .V:' Ske uttlhks: .ry _ � w.a � ' n i�-r-�� s"d/13n3 . Fd°� �. G �'� "�`�' .�«f� "`� zn�"; -�e,a``s _Catch basin or area drain 18.76 Job site address: sl{ , � � Dtywell,leach line,or trench drain 18.76 City/State/ZIP:'Tigard,OR 972.1.4 Footing drain(no.Iinear ft.: ) Page 2 Suite/bldg./apt.no.: I Project name:Northwest River Terrace Manufactured home utilities 50.03 Cross street/directions to job site: Manholes 18.76 Rain dram connector 18.76 Sanitary sewer(no.linear ft:—) Page 2 Storm sewer(no.linear ft.: ) Page 2 Water service(no.linear ft.: ) Page 2 Subdivision:Northwest River Terrrace Lot no.:50 Fixture or item: Tate parcel no Backflow preventer 1 31.27 Backwater valve 12.51 4," .�� 3 � • , 25.02 aivr__ Disitvdasher \ 25.02 Drinking fountain 25.02 4e:tors/sump 25.02 �� 'L Enmultontmk 2 s?;.,`, `4` ��.C-,g ' r .Y: s r,..s,. ` '? ... Fixture/sewer cap Name:ADVL Land Holdings,LLC Floor dram/floor sink/hub 25.02 Address:7600 E Doubletree Ranch Road Garbage disposal 25.02 City/State/ZIP;Scottsdale,AZ 85258 Hose bib 25.02 Phone:(602)694-4031 Fax:( ) aII.cce maker 1251 r .:. _x a .: • ^FM'EL, :'i,j s ` sa-.,"'' - ". 25.02 ,,. g... .< Medical gas(value:$ ) Page 2 Business name:'CM=Lyon Homes,Inc Primer 12:51 Contact name:Angela Grajewaki Roof drain(commercial) 12.51 Addis 109 East 13th Sweet Sinkibasinllavatory 25.02 Ctiy/StatdZlP:Vancouver,WA 98660 Solar units(potable water) 6234 Parona:(360)695-7700. I Fuc::;(360)693-4442 Tub/showedshower pan 12.51 Urinal 25.02 Small:Angela.Grojewski®polygatshomes.com w 25;02 i E 4 '` 3 ;, Nater beaten. 3732 - : ._ .. . .. . .... ... t- Business name: fir! � W Kel 4---Svest244,---- Waterpiping/DWV 56.29 Other. 25.02 Ci y/StaterET: 5T, e t arc. 411131 Subtotal /- 1(4— r�t�Pone: Faac{1.1 Q.."la'l /' Idmimum permit fee: S7250 _ Plan review (25%of permit fee). CCBlac: 184131 Plumbing L .no.PI3 631 State su (12%of pcñnit fee) Authorized:signature: TOTAL PERMIT FEE / This permit application ;permit is not obtained within 180 days Frmtaazn -'FV'� 1LLl,k Date. _36 has ccepted as complete. *Fee methodology set by Th.-County Building industry Service Board lath were tsimmU.PamitApi doe I0/01/09 43046163001O2ICOM EB) NIL City of Tigard 7 C a COMMUNITY DEVELOPMENT DEPARTMENT1 Building Permit Review — Residential TIGARD Building Permit #: "1.177-2-11/6 C FO Site Address: /• '- - -So ( nth L'ok_ Project Name: ei'ke/- i e AiO ?itXS9---- Lot #: 5*0 (New dwelling=subdivision name;Addition or Alteration=last name of owner) Planning Review Proposal: A erify site address/suite# exists and active in permit stem. River Terrace Neighborhood: ❑ No l!Q Yes,See River Terrace Review Addendum Attached Sid Plan Elements: �ree(3)copies of site plan ,o 'sting structures on site je plan must be on 8-1/2"x 11"or 11 x 17"paper Footprint of new structure(including decks)with finished rawn to scale(standard architect or engineer scale) or elevations lOrth arrow [Utility locations (required for new,may apply for additions) Aite address,project or subdivision name and lot numberla of wells/septic systems pplicant information(name and phone number) • ': ;sting trees to be retained with drip line,and tree Oil, yot dimensions and building setback dimensions rotection measures I11Lot area,building coverage area,percentage of coverage andreet tree size,type and location pervious area(applicable if R-7,R-12,R-25&R-40) Greet names Property corner elevations(2 foot contour lines if more than V 4 foot differential) TClean Water Services-Service Provider Let>j�r (lot platted prior to 9/10/1995): Required: ❑ es,applicant was notified No Received: ❑ Yes 1=1 No Public Facili s Improvement(PFI)Permit: lequired: Yes,applicant was notified ❑ No Applied For: Yes ❑ No,stop intake and Use Case#: AVQ06-D f ` o/c=�OS ter I Roning: -�� � equired Setbacks: Front ] Rear 0 Side 3 Street Side ivi4 Garage ,' v( andscape Requirement: �(7) LVJ 0/0 Lot Coverage Maximum: go 0/0 ❑ Building Height: Maximum Height OR- Actual Height Q-3- 10)`i )h isual Clearance 7 Easements 101°sensitive Lands: ❑ Yes No Type II Urban Forestry Plan ❑ Conditions "Met"prior to issuance of�y 1 b din permit Notes: 0�1'7d/7174M 3 .Sl , ,-- �, %�,�+�d" /kg C( Approved By Planning: __ Date: h / Revisions (after Building Submittal only) Reviewer Date Revision 1: ❑ Approved ❑ Not Approved Revision 2: ❑ Approved ❑ Not Approved Revision 3: ❑ Approved ❑ Not Approved I:\Building\Forms\BldgPermitRvw_RES_091216.docx J t Building Permit Submittal Original Submittal Date: o/3//,‘, Site Plans: ## 3 Building Plans: ## Building Permit#: L=1 Enter building permit#above. Workflow Routing: .❑' Planning L7 erEngineering C i'ermit Coordinator ❑,_B iiiding Workflow Sign-off: Sign-off for Planning(include notes from planning review) Route Application Documents: ❑—Engineering: (1) copy of permit application, (1) site plan, (1) building plan and original plan review routing form. Er/Building: original permit application, site plans,building plans,engineer and beam calculations and trust details,if applicable,etc. Notes: By Permit Technician: , ice 4 Date: /q. .3 f Engineering Review __ Slope at building pad: J .__— "❑ Conditions "Met"prior to issuance of building permit ./_,A.7" ❑ Easements (encroachments)per engineering conditions of approval and plat Water Quality/Quantity Facility: Assess Water Quality Fee in-lieu: ❑ Yes ❑ No Assess Water Quantity Fee in-lieu: ❑ Yes ❑ No LIDA Facility on lot: ❑ Yes ❑ No ❑ NOT Approved by ngineering: Date: Notes: 4,.. = _./z2), ..,,,,, 4,0 ta Approved by Engineering: /4,____P Date,/7 / Revisions (after Building Submittal only) Reviewer Date Revision 1: ❑ Approved ❑ Not Approved Revision 2: ❑ Approved ❑ Not Approved Revision 3: ❑ Approved ❑ Not Approved Permit Coordinator Review RECEIVED ❑ Conditions "Met"prior to issuance of building permit (---FEB 0 3 ZOjb e ;=�Approved,NOT Released: �;a ,__ otes: BUILDING DIVISION Revisions (after Building Submittal only) cv6 C. T=C.-e=:" S �" Revision Notice 1: Date Sent to Applicant: ,r Revision Notice 2: Date Sent to Applicant: %/5' V / Revision Notice 3: Date Sent to Applicant: SDC Fees Entered: Wash Co Trans Dev Tax: )Yes Tigard Trans SDC: Yes Parks SDC: es OK to Issue Permit Approved by Permit Coordinator: ;%��d�"V Date: 1// 8-1b a---- I:\BuildineForms\BldgPermitRvw 'I:\Building\Forms\B1dgPermitRvw REs 091216.docx M. City of Tigard II : . q COMMUNITY DEVELOPMENT DEPARTMENT T 1 c iz o River Terrace Building Permit Review Addendum Ir-,rx-,*, .s. , ,.. ,.a„ ,,,,«,#--• y,-,- .., =; xk _ ; kn..a r. z m^r„ .,<tk-tvr a,,,,. Nv*,,,,, a,.. ..•.ra: :.441 .a._ Building Permit #: /7i7 lc/ , -- pa-re-e) Site Address: / ".S0 c2t0 C*,2tn Project Name: ( 'Iv r- orve,e Acer- Lt-ls`7 - Lot #: (-- l (New dwelling=subdivision name;Addition or Alteration=last name of owner) Planning Review of River Terrace Plan Dis_tict Design Standards (18.660.070.1.): Is the project subject to the plan district design standards? 0 Yes El No 1.Articulation: a minimum of 1 element per each street-facing facade that has 30-60 ft. of frontage.An additional element required for lots with over 60 ft. of street frontage shall be provided every 30 ft. Porch min. 5 t. deep Balcony w/ access 2 Window Projection Vertical Wall Offset a ft. deep min. 2ft., 5 ft.wide min. 2 ft., 6ft.wide Gabled dormer 111CICI ❑ 2. Eyes on the street: a minimum of 12%of ea h street facing facade must include windows or entrance doors. Percentage Shown: �•//�J 3. trances:At least one entrance must meet both of the folio • g standards: Max. 8 ft. setback from long st street- facing wall Parallel to street,angle no more than 45° from street, or open onto porch Entrance opens to a porch: Yes ❑ No If es,all the following apply: f�5 sq.ft.min. ne street facing entry ft.max.roof above floor of porch V5 ft. depth min. 30%min.porch roof coverage 4. Detailed Design:All buildings shall include a min. of five of e following elements on all street-facing facades: ❑ Covered porch min. 5 ft.wide x 5 ft. deep Recessed entry area min. 5 ft.wide x 2 ft. deep ❑ all offset min. 16 inches ❑ former min. 4 ft.wide 'rny Roof eave min. 12 inch projection ©5 oof offset min. of 2 ft. ❑ Roof shingles either tile or wood ( Gable,hip or gambrel roof design ❑ Roof pitch oriented south min. 500 sq. ft. ❑ orizontal lap siding min. 3-7 inches wide CI Accent siding min. 40%of street facade l Window trim min. 2'/2"wide by 5/8" deep ❑ Window recess min. 3 inches for all street facing ❑ Bay window min. 5 ft.wide by 2 ft. deep ❑ Balcony min. 5 ft.wide x 3 ft. deep with inside access ❑ Attached garage is 35%or less of street facade . s •es and Carports:May face the front or side��lot11l}ne on a corner lot. Setbacks: 1 v No closer to front or side lot i. -,. •an longest street-facing wall. ❑ Ye 1 o. If No (Check one): ❑ May extend up to 5 ft.if there is a covere. - .orch a.• : age does not extend beyond the front porch. ❑ May extend up to 5 ft.where the garage is .. : a two- :. .uilding and there is a window at the second story above the garage that faces the street •: a min. area of 12 sq.ft. Width: (Check one) ❑ 12-foot- :.e garage door ❑ 40%max. of street facade 1'/o max. of street facade with 7 detailed design elements Notes: Approved By Planning: ,.,. —.0.0°Y,— _ --_ ..:,,7A Date: ___ZO4eill_e_ I.\Building\Forms\B1dgPermitRvw RES RT 062216.docx City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 Location: Inspection Date: 17303 SW GRANITA LN, SHERWOOD, OR, October 2, 2017 at 12:19:17 97140 PM Record Type: Record ID: Residential - Master Permit MST2016-00580 Inspection Type: Inspector: 199 Electrical final David Young Result: PASS Comments: No ac installed at this time. Violation Summary: Inspector Contractor City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 Location: Inspection Date: 17303 SW GRANITA LN, SHERWOOD, OR, October 2, 2017 at 12:02:26 97140 PM Record Type: Record ID: Residential - Master Permit MST2016-00580 Inspection Type: Inspector: 699 Mechanical final David Young Result: FA I L Comments: Seal around penetration at exterior wall for fresh air intake inside mechanical room. All else appears ok. No ac installed at this time. Violation Summary: Inspector Contractor City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 Location: Inspection Date: 17303 SW GRANITA LN, SHERWOOD, OR, October 2, 2017 at 11 :56:51 97140 AM Record Type: Record ID: Residential - Master Permit MST2016-00580 Inspection Type: Inspector: 399 Plumbing final David Young Result: FA I L Comments: Hard cap un used rain drain stand pipe right side front. Water pressure 45 psi. All else appears ok. Violation Summary: Inspector Contractor City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 Location: Inspection Date: 17303 SW GRANITA LN, SHERWOOD, OR, October 3, 2017 at 11 :16:53 97140 AM Record Type: Record ID: Residential - Master Permit MST2016-00580 Inspection Type: Inspector: 399 Plumbing final David Young Result: FA I L Comments: Correction from previous failed inspection not done. Investigative fee applied for scheduling inspections prior to corrections being complete. Violation Summary: Inspector Contractor City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 Location: Inspection Date: 17303 SW GRANITA LN, SHERWOOD, OR, October 4, 2017 at 10:53:34 97140 AM Record Type: Record ID: Residential - Master Permit MST2016-00580 Inspection Type: Inspector: 399 Plumbing final Aaron Cillo-Gobel Result: PASS Comments: Corrections completed. Violation Summary: Inspector Contractor City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 Location: Inspection Date: 17303 SW GRANITA LN, SHERWOOD, OR, October 3, 2017 at 11 :13:28 97140 AM Record Type: Record ID: Residential - Master Permit MST2016-00580 Inspection Type: Inspector: 699 Mechanical final David Young Result: PASS Comments: Correction complete. No ac installed at this time. Violation Summary: Inspector Contractor City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 Location: Inspection Date: 17303 SW GRANITA LN, SHERWOOD, OR, October 4, 2017 at 11 :24:38 97140 AM Record Type: Record ID: Residential - Master Permit MST2016-00580 Inspection Type: Inspector: 299 Final inspection Aaron Cillo-Gobel Result: PASS - CofO Comments: Final erosion control passed Street tree certificate received Moisture content form received Moisture barrier acknowledgement form received High efficiency lighting form received Insulation certification verified Blower door and/or duct seal test certificate received C of 0 left on counter. Violation Summary: Inspector Contractor