Loading...
8750 SW SCOFFINS STREET N i CITY OF TIGARD OREGON October 13, 1991 Ms. Mary Monnat Tualatin Valley Mental Health 1,,600 NW C:.:'^^' ' Rd Portland, Or 97229 Re: 8750 SW Scoff ins S`- Dear Ms. Monnat This letter is in answer to your question regarding the use of the above- iiferenced property, and whether it could be used to house five unrelated persons. L —wor is •rp« The building currently is classified as a single Lazily re5i.iut�u9+ state building code permits five persons u,k- '•,`_'d by bioud marriage to live together, and still. be r•onsidereo "family" . No changes to building will squired if used as a s-ale family dwelling. I strongly recommend that smoke detectors be p. ovided outside all sleeping rooms , and on all other floors. if you have any questions, please call me at 639-4171. Sincerely ) Brad Roast Building official I 13125 SW Null P.O.Box 2.3397,Tigard,Oregon 97223 (503)639-4171 - -- -- CITY OF T��A R® 4-25-90 OREGON Me. Mary Monnat Tualatin Vallcy Mental Health Center 14600 NW Cornell Rd `-- Portland, Or 97229 Re: 8'x50 SW Scoffinu St, WCTM 2S102AA Tax Lot 2900 Dear Ms. ho .at, An inspection was conducted today at the above referenced property to determine the necessary items to be provie.ed in order to use the building as a group care facility. You described t'ae intended use, as a facility provi.-ling living/sleeping facilities for a maximum of eight persons (adult women with possibly one child). The occupants will not possess any handicaps or disabilities that would prevent them from taking immediate action (without the ai.d of others) for self preservation, in the event of an emergency. Based on the information provided the use will be classified as an SR-3 occupancy, as described in the State of Oregon 1990 Structural Specialty Code. The following will apply: 1. The maxiwum number -if persons that m.w is eight. 2. The ma:.lmum r uiubei of persons that may occup•1 a bedroom is two. 3. The front door, vestibule door and d;mor from the first floor hallway shall be a minimum of 3 feet wide and 6 foot 3 inches high. 4. r;ach bedroom shall. be separated from the remainder of the building by a solid core door.. The doors shall be provided with d self-cloy+::-.w device, latching hardware and smoke gasket. 5. The front and rear exterior stairs shall be modified to pro- !de a maximum of 7 inch rise and minimum 11 inch run per tread. A handrail shag ', be provided on each side of the stairway. Handrails ahall be placed betweei, 34 and 38 inches above the nosing of t!,,a treads, shall extend a minimum c•f 6 .inches beyond the top and bottom ox the stairs and termlaate at a post or wall. A guardrail shall be provided on any landing or deck more rh&n 30 inches above grade. The guardrail Fhall be a minimum of 42 inches in height, and have intermediate rails spaced so a 6 inch sphere cannot pass through_ 6. The stairway to the second floor shall be r minimum of 36 inches wide. The maximum rise per tread shall be 8 inches and minimum run per tread shall be 9 inches. A handrail shall be provided. A guardrail shall be provided on the second floor around the stairwell opening with a minimum height of 36 inches, with intermediate rails spaced so a 6 inch sphere cannot pass �/�/.7/�' ,•'..( ... moi;-;_v a- �r...1 13125 SW Hall Blvd.,P.O.Box 23397,Tigard,Oregor 91223 (503)639-4171 - mr are-vlm!��Iim 1111illi the second floor around the stairwell opening with a minimum height of 36 inches, with intermediate rails spaced so a 6 inch sphere cannot pass through. There shall be a minimum of 6 foot F inch headroom mcabared vertically to a plane parallel and tangent to the nosing of the treads. 7. The stairway to the second floor shall be Peparated from the first floor, by �y walls and a dcor. The door shall be solid -,ore, with a self-closing device, latching hardwire and smoke gasket. L 8. The second floor rc.om at the top of and open to the stairway shall not be 7"d "` used for sleeping purposes. I/ 404( 9. All bedroom shall be provided with al least one window that complies for s.J emergency escape and rescue. The only bedroom without a window in 6 complinace for. size, 1.e located on the second floor facing easterly. Most of w the windows need to be adjusted or modified to he easily openable, some will require repair or replacement. of "counter weights". 10. The attic access opening shall be covered with a tight fitting panel of minimum 1/2 inch thick gypsum board. 11.. The basement shall be separated from the remainder of the building by covering the malls and ceiling with 5/8 inch thick type "X" gypsum board (walls which are of masonry or concrete are exempt from this requirement). There shall be a door separating the basement from the remainder of the building, the door shall be a minimum 1 3/4 inch thick solid core wood. The door shall be provided with a self-cloeing device and latching hardware. 12. The basement can only be used for light storage purposes. Continued use of the laundry facilities is acceptable. A minimum 3 foot clear area must be maintained around the furnace and chimney. 13. The Chimnel used for venting the furnace shall be provided with ar approved liner. The furnace shall be provided with combustion air directly from the outside. The combustion air shall be provided by ducting with an area equal to 1 squc,r.e inch for every 1000 BTU input rating of the furnace. one-half of the avea shall be located at the floor and one-half shall 1•,e locate, at the ceiling. 14. An approved electrically supervised fire alarm and smo',e detection eyatem shall be installed, the alarm shall be capable of being heard throughout the building. All rooms used for sleeping purposes, hallways, stairways and basement shall be provided with smok43 detectors. The system shall be installed in accordance with Article 14 of the Uniform Fire Code. Permits will need to be obtained for the work. to be performed, prior to con iencement. You will need to contact the Washington County Electrical Inspection department f-r any additional requirements pertaining to the electrical code. If you have any _ieStiOn, please Call me at 639-4171 . Sincerely Brad Roast Building Official cc: Jerry Renfro Tualatin Valley Fire & Rescue Converting R-3 to SR-3 Prompt response Srnall Board and Care, 6-16 persons Occupant Load 2/bed or N allowed by State License which ever is most restrictive. Separate sleepi.nrl rooms from any corridor and common ar9as by 1/2 gyp on walls, solid core a/c doors, smoke gasket. Table 13-C Min two exits, 1 primary, 1 egress i.-i ndow No unprotec':ed vertical openings into primary corridors. Stairs to have 1/2 gyp. Fire alarms and ernoke dot. per fire code standards 14-1 o supervised o smoke dot in ea Sleeping room o aux power for n, ntem min 8 hour capacity Ov � Address?ZJ -/,vPermit No. Name of Occupant Permit charge Gw►�+ec4iva'fee _- Paid by Date connected Type of Building Inspection fee_ Service Rate _- Paid by ___Date_— Contractor------ -- Assessment d 7J, e Q Paid__- _ Size of connection --- �I t i A.M. DATE -TIME-.--_P.M. M_ e-go -7 PHONE--- 4_ AREA WDF. SUMMER rxl*FNIIAION TELEPHONEO PLEASE CAM CAME TO SEE YOU WILL CALL AGAIN WANTR TO SEE YOU RUSH RETURNED YOUR CALL SPECIAL RITMWON MESSAGE. SIGNED LITHO IN U.B.A. TOP®It FORM 3002P