11481 SW HALL BLVD STE 102 7
4- ,.;
<:
4<I
TENANT
LLJ r
N
Ja
v4ALL 4R (OFF CE CENTER �
tf
Q LO
TIGA z
ID , OfRE Z cn 8
w �
o
5U I TE 102
0
� o
w Lu
5IDDER DESIGN ELECTRICAL CRITERIA GENERAL NOTES PROJECT TEAM PROJECT DATA �--
o t.
I. ELECTRICAL DESIGN CONTRACTOR WILL COORDINATE POWER, SIGNAL AND LIGHTING 1. SCOPE OF WORK INCLUDES INTERIOR TENANT IMPROVEMENTS - EXCLUDES 'SHELL' OWNER LN. PROPERTIES DESCKIPTIOR!: INTERIOR TENANT IMPROVEMENTS TO 2,
DESIGN AND PROVIDE 'ALCULATIONS IN CONFORMANCE WITH STATE ELECTRICAL (SEE DRAWINGS TITLED 'HALL PARK OFFICE CENTER' FOR SHELL INFORMATION) 11481 SW HALL LLVD, SUITE 100 32,135 S.F. TWO STORY OFFICE BUILDING
CODE ENERGY CODE AND DUILDING CODE. CONSTRUCTION AND AS-BUILT PORTLAND, OREGON 9'1223
DOCUMENTS WILL BE PROVIDED ON FL'ECTRONIC MEDIA, AUTOCAD 2. HVAC, PLUMBING, ELECTRICAL AND FIRE PROTECTION SYSTEMS ARE 684-5066 Ext. 219 LOCATION: 11481 SW HALL BLVD •��--
RELEASE 12 OR LATER TO THE ARCHITECT FOR THE OWNER'S RECORDS. BIDDER DESIGNED AND UNDER SEPARATE PERMIT. 624-0433 FAX ADJACENT TO SOUTH R.O.W. OF HIGHWAY 21.1 o
2. ELECTRICAL DESIGN CONTRACTOR WILL REVIEW THE F'f?oGRAM DRAWING 3. ALL BIDDER DESIGNED SYSTEMS TO COMTAX MAP 1 LOT 18135DA 1800 AND 3500
PLY WITH APPLICABLE CODES TENANT B.B.4S PSYCHOLOGISTS SUITE 102 rn
AND WILL MEET WITH THE tENANT TO FINALIZE THE EXACT POWER LOCATIONS AND ORDINANCES. 11481 8W HALL BLVD, SUITE 102 ZONING: G-P (COMMERCIAL PROFESSIONAL) `J c
AND REQUIREMENTS FOR EQUIPMENT. DEC>IGN WILL PROVIDE FOR CODE POW,LAND, OREGON 9-1223 z
REQUIRED AND MAINTENANCE RECEPTACLES. DESIGN WILL INCLUDE 4. THE CONTRACTOR SHALL COORDIN.;iE LIGHTING, HVAC AND FIRE SPRINKLER 684-5066 EXT. 219 BUILDING CODE: OREGON STRUCTURAL SPECIALTY CODE, 1998 ED 9
FIRE ALARM SYSTEM IF REQUIRED, COORDINATED AND EXTENDED FROM SYSTEMS 624-0433 FAX
BUILDING FIRE ALARM SYSTEM. DESIGN WILL INCLUDE FZv!EW OF THE OCCUPANCY: GROUP c ,
PROPOSED LIGHTING PLAN AND MODIFICATIONS AS NECESSARY TO 5. ALL BIDDER DESIGN ITEMS TO BE DOCUMENTED ON BASE FORMAT AUTOCAD GENERAL CONTRACTOR PACIFIC CREST STRUCTURES
ACHIEVE PROPER LIGHTING LEVELS AND COMPLY WITH EMERGENCY DRAWING PROVIDED BY THE ARCHITECT. AN AUTOCAD DRAIiI�.s CONTAINING 1301 SW KABLE LANE, SUITE 100 CONSTRUCTION TYPE: 5N, FULLY SPRINKLERED
EXIT LIGHTING CRITERIA. WORK WILL INCLUDE VERIFYING C:U51CL E SERV!CES, AS BUILT CONDITIONS SHALL BE FURNISHED TO THE ARCHITECT UPON PORTLAND,
LOCATION AND DISTRIBUTION. COMPLETION. 968-8949 OREGON 91224 TENANT AREA: !,175 SF
598-6658 FAX
3. ELECTRICAL DESIGN CONTRACTOR WILL COORDINATE #418 WORK WITH THE 6. CONTRACTOR SHALL SCHEDULE A PRE-CONS'iRUCTION MEETING BETWEEN THE CONTACT: ALAN VOLM
ARCH!TE'T AND WIT14 THE HVAC AND FIRE SPRINKLER DESIGN/BUILD BUILDING OWNER, 4RCHITECT, TENANT, GENERAL CONTRACTOR AND ALL s.
CONTRACTORS. DESIGN/BUILD SUBCONTRACTORS NECESSARY TO ENSURE COORDINATION ARCHITECT WADDLE DESIGN-PLANNING-ARCHITECTURE ESTIMATED VALUATION: $38,24ro.00
4. ELECTRICAL DESIGN CONTRACTOR WILL MEET WITH THE TENANT TO
COF THE WORK AND TO RESOLVE ANY QUESTIONS THE PARTIES MAY HAVE. 1100 SW 4th, SUITE 105
_
DETERMINE' AND/OR CONFIRM THE LOCATION ION :.JF ALL DATA AND COMMUNICATION 1. CONTRACTOR SHALL PROVIDE A VENDOR AND SUBCONTRACTOR LIST IDENTIFYING PORTLAND, OREGON 91201
CONNECTIONS REQUIRED AND INCLUDE CONDUIT, BOX AND PULL STRING IN THE COMPANY NAMES, CONTACT PERSON AND PHONE NUMBERS AND DISTRIBUTE TO 221-200 FAx INDEX OF DRAWINGSJ
REQUIRED LOCATIONS UNDER THE T.I. CONTRACT. WIRING AND CONNECTION OF EIUILDING OWNER, TENANT AND ARCHITECT.
THESE DEVICES IS N.I:C. N
8. HVAC BIDDER DESIGN CONTRACTOR SHALL MEET WITH THE TENANT TO MECHANICAL CONTRACTOR D.L. HOWARD COMPANY TO.1 COVER SHEET
5. LIGHTING SW!TCHING REQUIREMENTS ARE AS FOLLOWS: COORDINATE ALL SPECIAL REQUIREMENTS, ZONES AND CONTROL LOCATIONS. 5340 SW DOVER LANE t1.1 TENANT FLOOR PLAN
PORTLAND, OREGON 91225 T2.1 TENANT REFLECTED CEILING PLAN
ALL OTHERS 3-WAY SWITCH AT ENTRY POINTS 246-6164 T3.1 SCHEDULES JJ.J
DR OFFICES (3): SWITCH AT ENTRY POINT 293'0229 FAX �-
CONTACT: LEAN HOWARD �-
6. DETERMINE AND PR
OVI'JE ALL NECESSARY PANELS , EQUIPMENT AND PLUMBING CONTRACTOR TO BE DETERMINED VICINITY MAP '
CONNECTIONS TO S!=�,IE THE SPACE FROM TF'-? MAIN ELECTRICAL ROOM
ON SECONL -�.c-1�Fc
ELECTRICAL CONTRACTOR TO BE DETERMINED F�'
FIRE PROTECTION TO BE DETERMINED _
eew Ln
CONTRACTOR Z _ 1
217 � �, v ~
T
1y1
CITY OF o
Q Approved..... TtGQp�O
p i
Con •...........
.,4• ditionally APlkoved., - cn
For only the w U
PERMIT crk as de crib0d irt:
Qe NO._ 47
-,-
Atiao►i..... 0L V
.1ob Address: Q,... ... ...
� ay:
� � a
N
.r PL AN � 11481
48' SW HALL BLVD#102
" 9"-00376 1of4 r (P
0
� n
- - (p
m w Q w
` O Q C
L y
- IENANT
AREA
1,175 8F
T007
. r.
FILE: 99507T07.dwg
.,.. .,....,,p.., «c..:...... �-.,•+„ : yam..... . ..
NOTICE: IF THE PRINT OR TYPE ON ANY ►�'Ir IIli� ll II�III► VIII I 111111 VIII !�lfrll r�T�Trr r�rl!rr rill ! Ijlllli Ilr�ll► 1�II!�I VIII ! I I I I I I I I 1 I 1'I I I I III I I I Jr
IMAGE 4S NOT AS CLEAR AS THIS NOTICE, ( 1 I I I I 14 I 1� 3
IT IS DUE TO THE (QUALITY OF THE No 3e
_,...r
f►��E I►sORIGINAL DOCUMENT I��II!I� �I��IIIII�I��II��� ���s►�IzI��� ►��I zI� � IIil --- - T -- --- �E Fill it► ill7iJilz1111i ,111 ,111
11118 � I9����IIIII1Ii .1
�• r ^
,. G•`�4
CL
GENERAL NOTES
I , I. FLOOR PLAN DIMENSIONS ARE MEASURED A5 FOLLOWS: —
EXTERIOR WALLS:
FACE OF CONCRETE LLJ .-
CENTER OF COLUMN (GRID LINE) N g
INTERIOR WALLS: C, Lk::
FACE OF FINISH (FACE OF GYPSUM BOARD) LiJ C>
CENTER OF COLUMN (GRID LINE) F- .
CENTER OF PARTITION oma-.
U •;gi
2. FIRE EXTINGUISHER(5) (F.E.) SHALL BE PROVIDED IN C <[ n-
OFFICE OFFICE PUBLIC AREAS AS SHOWN ANTU AS REQUIRED F3Y THE FIRE MARSHAL. �
T116515 TIIbCt OFFICE FE-1 2A-1036 FIRE EXTINGUISHER WITH CARSON "CAMEO" WHITE
711(oM
SEMI-RECESSED CABINET WITH CLEAR ACRYLIC BUBBLE. CD °'
FE-2 = SAME AS FE-I EXCEPT SURFACE-MOUNTED CABINET WITH
�HWR
c ` I, I SHWR z
■ ' ; FLAT ACRYLIC DOOR PANEL.
PRINTERS III I I il0 _ FE-3 = SAME AS FE-1 EXCEPT FULLY-RECI-55ED CABINET WITH �N
T116G I }�
�I! EQUIPMENT CL09 CLEAR ACRYLIC BUBBLE.
- T116K
T1161-1 TN r c-
OFFICE 3. COORDINATE LOCATION OF SMOKE DETECTORS AND
SPRINKLER HEADS WITH LIGHTING AND HVAC GRILLES.
T116F 3`
VERIFY PROPOSED LOCATIONS WITH ARCHITECT. C7 v'
.. MEN } ...._................ WOMEN
111 ........
\ '' 109 4. ELECTRICAL OUTLETS INDICATED FOR SPECIAL OR UNUSUAL W
REQUIREMENTS ONLY. SEE BIDDER DE51GN ELECTRICAL
/ r" .` RECEPTI�
EXERCISE FUTURE OFFICE
CRITERIA - SHEET TO.3. WHERE AMPERAGE 15 INDICATED,
} .., ...... TII&J
T11i PROVIDE SEPARATE CIRCUIT.
IDUPLEX ELECTRICAL OUTLET
BREAK
v I
•
T116L 0,UADR.4PLEX ELECTRICAL OUTLET
.. ...... - GU3ICL E POWER - TO BE DETERMINED BY TENANT AND
VERIFIED BY ELECTRICAL DESIGN CON � G + +
CONFIGURATION ..
ELEC.
I PHONE
fot } 108 DATA
Tll
5TAIR
113
CORRIDOR101 NUMBERED NOTES
-)
- O PROVIDE NEW OPENING IN XISTING WALL Z
i WAIT �o --
.-
L---J - TI02A 7 ---
8 Tto2 `� 0 PROVIDE PLAM COUNTER 36" WIDE a 36" HIGH. PROVIDE a'
12 iCE� a I DI BLDG. STOR 3'-0"x3'-0" SLIDING WINDO T, OPERABLE/LOCKABLE
L
TI02F� �^ T118 FROM ROOM T1025. 5EE - IA ¢ r
12 WORK Ai - 2
C3 ,`�® - -- _��m" Im'-m" GONF. tab (v
Lam- c
SHIPPING/ T1155 3 c
J ® G
RECEIVING TOR. Tioz Li—
� � �3 CENTER WALL ON WINDOW MULLION - SEE Tab FLU5N ON EAST FACE � SIM.
102D �- -
Lo
1 HALL
DI T102E D1 1..6°MI 4 O CENTER WALL ON CEILINCz GRID - SEE Tab Q'
N N - OPEN OFFICE 5 PROVIDE STUDS, GYPSUM BOARD 1m n
4 DI o o TI15A 4 INSULATION AT EXTERIOR WALL(5) - SEE
v
D1 - D1 O TEMPERED GLASS RELIGHT - SEE 1 o
Tab 3
OFFICE OF�IGE OFFICE OFFICE O EX15TING STUDS, INSULATION AND (1) LAYER GYPSUM BOARD - 00
4'46" 14 111-011 7102F T102G T102H T115C INSTALL (1) LAYER GYPSUM BOARD ON TENANT SIDE OF WALLZ (L
Q'
OEXISTING TO REMAIN.
5 3 DEMO WALL AND REUSE DOOR 4 FRAME
- — — — -- - — LEGEND .r.
EXISTING WALL T.O REMAIN
NEW WALL
NEW LOW WALL (NOT USED)
O
O
O ==X=== LOW WALL STIFFENER (NOT USED)
O
Z
W �
TENANT FLOOR FLAN
� aD
V)
Z Q
a �J
F
�i ED
U �
a
v!
11481 SW HALL BLVD #102 �' €
RUP1999-00; 76 2of4 N
INTERIOR WALLTYPES LEGEND ca
W-LEGEND
2 1/2" r 5/8" 5/8 2 1/2" X5/8" 5/8 2 I/2" 5/e" 3
TYPE 'X' GYPSUM BOARD - - - /8"� EBXOG PSUM - - /8O" T
" � —5/8" TYPE 'x' GYPSUM BOARD -- _ � '__ 5 TYPE 'r BOARD _ - 5 TYPE 'x' GYPSUM BOARD
-� - - -
FLO RTO TTOM OF ,.FILING
FLOOR TO STRUCTURE ABOVE 0�
FLOOR TO ABOVE CEILING LINT _ 1 FLOOR TO STRUCTURE ABOVE _✓�; _ g _g BOTH SIDES TENANT SIDE ONLY
TYPE 'X' GYPSUM BOARD . - - (PROVIDE FIRE SAFING AS REQUIRED) _ r AFF-----'qu- I �i L�
FLOOR TO STRUCTURE ABOVE CEILING: - - --
`n 1/2 25 GAGE STEEL STUDS g 24 OC 3 5/8 25 GAGE STEEL STUDS � 16 OC
�`— 2 1/2" 25 GAGE STEEL STUDS is 24"OG 2 I/2" 25 GAGE STEEL STUDS o 24"OC �'� 5/f5" TYPE 'X' GYPSUM BOARD -
r
BOTH SIDES OF - _
SOUND INSULATION AT AI -- SOUND INSULATION ATtB'r 3 5/8" 25 GAGE STEEL FRAMING g 24"OC -C _ TENANTSOUND INSULATION AT D1 SOUND INSULATIONAREA °�FLOOR TO STRUCTURE �BOVE FLOOR TO STRUC,TUREOVE �� - _ 1,115 3F � o o ��
SOUND INSULATION AT�C� FLOOR TO CEILING ABOVE FLOOR TO STRUCTURE ABOVE
FLOOR TO CEILING ABdVE - AND 5'-0" HORIZONTALLY EACH WAY _
` ON TOP OF SUSPENDED CEILING
-- --WALL.: _;
DIMENSIONS FROM FACE OF DRYWALL - DIMENSIONS FROM FACE OF DRYWALL _ I 5/8" T'rPE: 'X' GYPSUM BOARD -� DIMENSIONS FROM FAGS OF DRYWALL -- DIMENSIONS FROM FACE OF DRYWALL
DE5 OF
5/g" 2 I/2" h5/8" B02'N251 GAGE STEEL FRAMING 24"OC fi TENANT PA TITION D- EMIS�IN„G A_RT_ITIO_N <EY FLAN
Fr RSTFLOO
R
NON-RATED WALL ONE HOUR WALL TO STRUCTURE ONE HOUR WALL/CEILING "TUNNEL"
QT107
�- FILL: 9950111 i.dwy
„
NOTICE: IF THE PRINT OR TYPE ON ANY
[—_ - I-- II I I I I
l OJC 3
IMAGE IS NOT AS CLEAR AS THIS NOTICE,
IT IS DUE TO THE QUALITY OF THE "°'°
ORIGINAL DOCUMENT 1t 8'Z S�I�III.III IIII IIII I �11
IIIIL�ZIIII�IIeIIZI I,II1 II IIZllll� (f� TllETll II1IlZ"ll ll111111
ililI
81►I l
�IIIIIeIII��Wl�Llll�uu1l9l!Illll 4 £ � Zu11I lOT a I�IiNie-I
II
4.
%E,
I I i 1 1 I I 1 1 1 I I I I 1 1 ' I ........ ....... ••^!� �1 �.�,
I I 1 ,
I
-- �- 11
OFFICE t """""wly.............. ......... ""�"�""'.... ._. '""��... ..........
' ' .�. 1 1 I I ••••• i 1 1 � ; i 1 I I �
I 1
TII&EI � � .... .L......... .i ... ' ............'........... ....�.......... .� .......... ..a....... ............ .......... ..;........ ..... ..,.._......._-,....... .p.........•......,............ ..i............ ......... , .,............ .,.,.......... _,............
I
OPEN OFFICE ' ' O
;. ......... 1 ; TII&DLLJ
_........._.._..... ;...... .
, I
. , , I I I I I 1 I I I ' � •• ['A�'�
- - I
I
1 I
......,. ........ .... .. _. ,.. '.1,
O� G
F ICE OFFICENQy
T TIIb GI
I b C� O V)
I
x ' J T
I0-4 I
1
�PRIN RS i I ........ . III ® li0
-. . .. - IbG _ I r
• I I � WO.iaK .. EQU PMENT
ALET -
... . . . ,
I ---- T116K
I I I
TI16N, --- TII&N Z
�JE
F : ... .
i
I 1
I I _ r
I
I I
I I
MEN � � WOMEN
�
_ . 112 109
- ----------
------ l� I
I I I
—--
:" -
L JI ® ------ -- BREAK TllbO
RECEPW
I I
T11bJ
---- u TIIbL
I 1 1 I �
I 1
- - =------- ------- - - - - --- --I -,-------;--------,----------- ® Z
I I
I ,
,-
�Il - 7
CONFIGURATION---;--------;------ i------- - '--- '--- ' -- — r --- - --�- --' - -' EL108 I---� r�--
TI1bC , - - i--- -- 1--- - - 1 108 - ------- -
I
I
_ _'_-_'
----_ __-^---�^------ I_ - I I 1 1 ' I 1 I 1 1 1 1 I I I ' --- I---r---r---�•---' ' �---r--- ---�_.
�III���I(---�III1'III_- -r...__ r•---+---r--- r__'r__'� I�IIIII���II�}II'L' C/�1'1f'V�1���Iy',`_
• _,. ----I---- 1 I -_o-- I•_--r--_�_•- �r------- •___r---r---rn---r----•---1•---I�T---r._-�.-_-�._- r �� -_- _-- •_-_r___►_-- _-_r_--•r_-_1•_-- __-r_-.-r--_r-_- __-r__
I _- --__.---1____-_�__---- - I 1 1 1 I I I I I I , I 1 1 I I I 1 1 I I 1 1 1 1 1 I
1 1
1
y- -
--------------------------------
EY
7102 A
• I I 1 I I 1 RELOC. --'--- ---- ' ------- ----------
(E) ----
---'--------•'-------! - -- -- - - ------ -- -- -'••
I
:
' -- ---- --- - ----- ----
12
-- I 1 -- ----- --- -- -
12 D I! II 1 I i OFFICE BLRCs. STOOL ----- - - - -- --- ------ -
tr >�" ,II1IIIII������—��---—��y1�IIyIII; ,
• � ' ------- -- ----' 1 I ---- 102 � - --- -, 1 Q)
I
--•---+-- IllORK T B T118
12 ; 1 COFFEE
-- - - - - --- -- -! ---- ---------'--------'------ - '---- c
I I
____ _
------'----- -- - 1 CONF. c
I
1 -- - 102C ;�' I v
T1 l3
-•---$HIPPING-/ ----� --�-- -- -�. _ � ---'------- -- --- -- ----;--- ---'--------;--------- - , - ,- � �
}��EIVINCa I TO
- -' i I r07 —►� ------------------------
------- --- --- -- - --- ------� - ---
I
i !
, t 7 i
i I 1 1 TIO s � ,,J11'1(1'1��11111 —
-- -- -----------;-------' ------'-' 1 1 7S.'1 I 1 1 1
i I
_ _
OPEN OFFICE
1 -- --- ---i 1 I I
4
---------------I ' ' ' -L-------L-------.. ----'L`------L----•--_L---.
I
4
cE��L ' ------ 1 ----- ------ ---
------------- --- - ---.-"`- 1 I I I - _ - , - -- rI�1 -- ---- __._ __ Q7
FEn
1 I ♦ OFFIC-E' OFFI -- - IC - OFFICE----L---.15G --- -------- ---- ------ ------- ------ ------- ------- --... A
//gy�,pp pI ; 1 I
I
-- I , 1 1
- ; T102F' T1026 ; ;
"rT
I 'T102H ' I 1
I1 1 I _ '--- ------ - ----- - - ---- -
11_jI
I''� i
MT
I 1 I I I �J _.._ - ----_' -_ - ' ---.-_--L-------' I ----- -- - --- - .
_ _ - _ _
(E)FELdC.
1L-- __.-__ . _______L _______�-'__-- - -
J.--'--`-_I ------------
7.
_ i
F
CEILING EXISTING CEILING NEW
o
O
O
-- 121 SLACK WIRES EACH LIGHT FIXTURE PLUS TIGHTtu
EYE BOLT TO ROOF STRUCTURE COUNTERSLOPE HANGERS IF %
WIRE TO MAIN RUNNERS EACH RUNNER PROVIDE
MORE THAN 1 6OUT OF PLUMB POSITIVE CLIP FOR FIXTURE TO MAIN RUNNERS
• ROOF STRUCTURE
TENANT REFLECTED CEILING FLAN � � r12GA - o0
LATERAL -SECURE ALL V!
BRACING \� HANGERS TO }-
1�81,_11-0,1 a D ADDITIONAL HANGER L BUILDING
ALL MEMBERS w/IN STRUCTURE- L.LJ `J
8'OF PERIMETER 1 CROSS RUNNERS � -- TRAPEZE � �
STABILIZER BAR- FIT BETWEEN OUCTWORK
BETWEEN ALL _l MAIN RUNNERS AND OTHER Q < ~
CEILING LEGEND - -- --- - , LARGE v)
MEMBERS® OBSTRUCTIONS W
yN' PERIMETER I I -MAIN RUNNERS(P 4 0'O C SUPPORT - i Ld 1�
W/rf2 WIRE � 4 0'a C 1�1
_;__ -2X4 SUSPENDED CEILING SYSTEM - 2x2 TEGUL.AR EDGE ALL WIRE TO 8E 12 GA Q' = 1J
8'MAX 4'-0'0 C 4'-0'0 C I U1
{ i i MILD STEOLTWIRES
ANNEALED
♦ I RECESSED CAN DOL1N LIGHT 4'-0'MAX 12'•0'0 C EA WAY
- ' --- SEE PLAN FOR LATERAL BRACING 0 12'-0*0 C EACH WAY-MAIN RUNNER TO
WALL TYPE STRUCTURE BEGIN BRACING WITHIN 4'-0'OF PERIMETER 6 SEE PLAN FOR
2x2 RECESSED FLUORESCENT CQUl
2'FROM CROSS MEMBER WALL TYPE (�
2x4 RECESSED FLUOREGSENT Il-
wRECESSED FLUORECSENT ON EMERGENCY BACKUP CIRCUIT SUSPENDED CEILING BRACING m �--
6 EXIT LIGHT - WALL MOUNTED NO SCALE 11481 SW HALL. BLVD#102 N
BI JP1999-00376 3of4 "t
141 EXIT LIGHT - CEILING MOUNTED WITH DIRECTIONAL ARROWS
Ex HvAC SUPPLY DIFFUSER <
HVAC RETLIRN GRILLE
♦ RECESSED CAN DOWN LIGPT ON EMERGENCY BACKUP CIRCUIT
r
TEN-AN
0
AWA
T
1,115 SF O
<EY FLAN - FIRST FLOOR O0
2I"=40'-O"� QD
T2m7
FILE: 99507T27.dwg
No-
NOTICE: IF THE PRINT OR TYPE ON ANY f Ill-Jill 111l1l1llllllllllllllll il � llllll � lll l II1I1 �1I1�1I1Ir Illllllllllll 1 11111 Jill IIIIII►�1 r l�lfl(lI1�tI!(1 r�rllllllilll 1t t( tlt(11t11 1(1 1�1(l�lll�r�lll IIII►Illl(Illl S 05
IMAGE IS NOTAS CLEAR AS THIS NOTICE, l L -1� - — 'l ---- - L-- - 4L -_ L ----- L...__ __ _I _`.. L_ II--I-$I ---- --�'�--- --���—II---- 11�---_IL �j+I �.�
IT IS DUE TO THE QUALITY OF THE No 30
ORIGINAL DOCUMENT �'i
S 6 8Z LZ 9�Z Z �Z >JZ Z TZ 4Z 611 9i LT 9t 9T 1bt £T ZT TT T 6 S L 9 4 �I�uN
�
i �I �� II i iii ii1r1iiiIiii�liiii�riiliiii�iii�liiii1iiiiii�iiiiiii1iiiilii ii��I������il►►►` ►►1�� ����!���������I� l����lul� LLI� ��T�� ��
rq
- r
f -- I x WOOD CAP, PAINTED
r 3/8"x2" WOOD TRIM, PAINTED `�� '•
-� 5/8" GYPSUM BOARD ON
F7
SEE `ALAN 3 5/8" STUDS A 24"OC Y
- -_ _ - - 1/8"x3" PL I�" f J • yJ
W/ (4) EXPANSION ANCHORS
INTO SLAB Q 3"OC, STAGGERED
AND (3) 3/8"0 BOLTS THRU U15L—
SEE PLAN FOR BRACE LOCATIONS STUDSLAJ
o
9 -D r-
i--
0 / F BRACE TO 5TRJCTURE �v
(
4'-0110C AND AT ALL - - EXTERIOR WINDOW � _
r3-rd
W
DOOR 5'Cr21KE JAMBS MULLION ~
COMPLY WITH UBC FOR ALL - = o,^
�- - -- - REQUIRED BRACING, F --- J-TRIM +
/ CONNECTIONS AND MATERIALS i vv Q
\
GLASS t _ o
0 A* I i I • SEALANT �
FLAN
SLIDING CLASS I __ I _
5/b" TYPE 'X' GWB - I z
l,J!TH LOCK - CEILING TILE ON 2 1/2" 5TL STUDS Z
L : TRIM. Ti P. --n. _
_ Q i WALL BEL OW 111 2..
--SCREW TOP RUNNER TO ! —M J
V111
�
/^� * p }�,� III /� }� I SCISSORS CLIPS --- !
E L E V,-°1'Y 0I V I\OI W A I I G I. ATTACHED TO CEILING
GRID •+ 16110C
SECTION PLAN Z ,
I ............ r�.j......... g
C, E PTIONDESK PLAN ELEVATION INT. WALL 6 CEILING INT, WALL EXT. MULLION ION LOUD WALL WITH 5RACE o
I/2"=1'-0" 3 ■I -0 9'11m3Dm4 3 ■I -® 91103003 1 1/2 -1'-0 9g501D01
O
ROOM FINIeH SCPEDULE MATERIALS LEGEND (TO BE SELECTED)
FLOOR NORTH WALL EAST WALL SOUTH WALL WEST WALL CEILIWs MARK iATERIAL DESCRIPTION
No. ROOM NAME - REMARKS
MAT'L EASE MAT'L FINISH MAT'L FINISH MAT'L FINISH MAT'L FINISH MAT'L FINISH z
ACT SUSPE14DED CEILING SYSTEM ARMSTRONG SECOND LOOK 2x2 TEGULAR ]z
T102A WAIT C'=T-1 R5_1 GWB PT-! GW5 PT-1 GWB PT-1 GWB PT-1 ACT FAG
— __-.- --- --- I-- -- - - — - - -- — --- CONIC CONCRETE NOT USED w
T1025 OFFICE EX15T EX15T EXIST EXIST EXIST EX15T GWB PT-I EXIST EXIST EXIST EXIST kJ L
CPT-1 CARPET MATCH EXISTING
1102G WORK/COFFEE EXIST EXIST EX15T EXIST GWB PT-I GWB PT-1 EXIST EXIST I EX!ST EXIST ul
GPT-2 CARPET NOT USED Lu rn
T102D STORAGE EXIST I EXIST- EXIST EX15T EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST
NEW - NEW — NEW NEW
CT-1 CERAMIC TILE NOT USED O c
I T102E HALL �IS -XIS GWB Pt-1 GWB PT_1 GWB PT-' EXIST EXIST XISt IST L
- FAG FACTORY O
T102F OFFICE EXIST EXIST �' EXIST EXIST EXIST EXIST GWB - PT-1 EXIST EXIST
-. -- - GWE3 GYPSUM WALLBOARD SMOOTH FINISH (PAINTED) MATCH EXISTING
T102G OFFICE GPT-I R5-1 61WB PT-I GWB PT-1 EX15T EXIST ACT - FAC -
0—
n
- -- MRGWB MOISTURE-F:ESI5TANT SMOOTH FINISH (PAINTED)
T1021-4 OFFICE — - T 1- - - -_- GYPSUM WALLBOARD � .4 �
T118 BLDG. STORAGE PT 1 PAINT MATCH EXISTINGSLI 00
3
PT-2 PANT NOT USED a'
R5_1 RUBBER BASE MATCH EXISTING z
R5-2 RU5P3ER BASE NOT USED 7--
SF-1 SHEET FLOORING NOT USED
, .�..
5F-2 SHEET FLOORING NOT USED
` 1�OOR SCHEDULE DOOR TYPES
Z...............................
5T-I STAIN AND LACQUER NOT USED
b...................._
DOOR FRAME REMARKS
No. SIZE T14K TYPE FINISH TYPE FINISH
T102A1 3•-0 x 1-0 1 3/4" A ST-I TIMELY PT-1 EXISTING - RE-KEY TO TENANT / l \ \ j �j �^�,/�- ✓� CNI
T102A2 3-0 x 1-0 13/4" A ST-I TIMELY PT-1
T1025 3-0 x 1-0 1 3/4" A ST-I TIMELY PT-1 OI ul
---- - -RECESSED
T102D 3-0 x 1-0 1 3/4" A ST-I TIMELY PT-1 EXISTING TO BE SALVAGED DBL. TRACK .. _.. ....... .._........_......_._............- 5
T102D1 6-0 x 6. 8 13/4" A ST-1 TIMELY PT-1 U � VAP R BARRIER AND�J L-J R-11 INSULATION SYSTEM TO DECK
T102F 3-0 x 1 0 1 3/4" A S'f-I TIMELY PT-1 O 2 FLUSH FLUSr; V YL FRA E W/ 3 5/8 METAL STUDS m t4 OC
-- -- ----- SOLID CORE IaOLI OW GORE TE PERED G ASS
T102G 3-0 x 1-0 13/4" A ST-1 TII"IELY PT-1 O C O MAPLE BI-FOLD SLIDER 0 J
PAINT GRADE 1" AIRSPACE - Z
_ BIRCH SEALANT �— -- — -- _ LB.O. CEILING O I--
TI 24, 3-0 x 7-0 1 3/4 A ST-I TIMELY PT 1 I 2 3 FIXED GLASS PNL.
0 O C � LL-
9'-
T.O. LONG. OPEN'G OIL
I �
T118 3-0 x 1-0 3/4" A ST-1 TIMELY PT-1 1 m 0 AFF W W
3'
5USPENDED CE IL IN:-s
-�— HEAD JAMB SYSTEM - BRACE PER
UBC STANDARD 41-10a U
5/8" TYPE X :,YPSUM BOARD
n�n
I CORNER AND EDGE TRIM,--------Sj—y 8,0. GONG. OPEN'
NCi TES= — RECES:''iED TYP. ALL CORNERS AND EDGES
�. DBL. TF!ACK 2 -(o AFF
+�
�1) LOGKSET. CONTRACTOR TO VERIFY EXACT
(V
KEYING REQUIREMENTS '.'J/ TENANT. P. LAM ,
— COUNTER TOP 5/8" TYPE X GYPSUM BOARD ---
!\� ACOUST,G GASKET' ON 3 5/8" MTL STUDS tv 24"OC, TYP.
n ACOUSTIC SEAL AT BOTTOM.
�/ 1" AIRSPACE, TYPICAL -
TILT-UP CONCRETE PANEL (N.I.C.) ——?
5/8 G rF'SUM BOARD ON1 J I >r (P
3 5/8 STUDS m 24 OG I (P
41/4" al �
.... Ll
- - T
T.O. CONC. SLAB Z Y
_ -0 -0 AFF LL1 I U
f1
f-
4, �
3 S
SILL
RECEPT. DES< WINDOW EXTERIOR LArLL
J 3"=1'-0" 99501D02 I 90510D?)I 'T367
p
i 11481 SW HALL BLVD #102
BUP1999-00376 4of4
FILE: 99507T37.dwg
NOTICE: IF THE PRINT OR TYPE ON ANY 1111l111 III IIII! 111111 ! I ! ! dill III III I II' � �I III' lll Ih1�III III 111 I VIII III III II!'Iill III III I I III III III III II . 11t III I�I� IIIIIIi I�IIiIIII� III III IIII111 ' III III 11111 I l r
IMAGE IS NOT AS CLEAR AS THIS NOTICE, I1 —`*L I I- L I -I- �_61_. I , I LI I---I - I gL -I - I
IT IS DUE TO THE (QUALITY OF THE j —- No 36
l � II –III �� l11111111111II11 � 1 � ��I � Io�tLi6I jllll I11Jllllll�llllllll�llll lipORIGINAL DOCUMENT !1WL
I �III� I1�1�Elill! �yIIIl�1IIIII lI1l1..11IIIIIII III111w-, llI
lilllll