Report (11) 111srpey .00026( T 5-fr U s6/ 7z7%-,t-trrsrs INC 180 Nickerson St. Suite 302 Seattle,WA 98109 (206)285-4512(V) (206)285-0618(F) asolomon(d ctengineering.com BULLETIN Date: January 24,2017 Number: CT-03 Project#: 16043 Project Name: River Terrace MF Attached: None Subject: Air pockets in concrete walls (Lot 34) Drawings Affected: Description/Action; This bulletin provides response to RFI, design clarifications and/or variation requests for the 'River Terrace MF project located in Tigard, Oregon. Based on our review of the plans and the photographs provided by Polygon showing air pockets in the concrete walls, it's our recommendation that the following repair be done— " Chip out/remove all remaining poorly consolidated concrete and thoroughly clean out the air pockets to eliminate any existing loose debris *Apply a concrete bonding agent to the air pockets "Apply a high-performance non-shrink grout to completely seal/patch up the air pockets N0 PRO G I NF 60 w r REG N 22, T. 01/24/2017 CALL WITH ANY QUESTIONS Issued by: Arnold R. Solomon Date: Jan. 24. 2017 Distribution: Contact Information: • Chris Walther Polvaon Northwest Company Angela Graiewski Polygon Northwest Company David Burnett Milbrandt Architects SM 6043 River Terrace(Areas 1 &2)1Bulletins116043_2017.01.24_CT03_Air pockes in concrete walls(Lot 34).doc Structural Engineers