15405 SW 116TH AVENUE-1 ADDRESS: -19i'D5- Sw Me Oki& SHS.. IrAMAWn a Y c.� I:lrecordslmicroflm\targels%uilding.doc W J 6/40/ T UALATIN VALLEY FIRE & RESCUE AND BEAVERTON FIRE DEPARTMENT 4755 S.W. Griffith Drive• P.O. Box 4755 • Beaverton, OR 97076• (503) 526-2469• FAX 526-2538 June 12 , 1991 Ankroin Moisan Architects 6720 S.W. Macadam Avenue, Suite 100 Portland, Oregon 97219 Re: Oregon Medical Eye Clinic 1 15405 S.W. 116th, Suite 204 6188C-103-020 Gentlemen: ' This is a Fire and Life Safety Plan Review and is based on the 1988 editions of the Fire and Life Safety Code (UBC) , Mechanical Fire and Life Safety Code (UMC) , Uniform Fire Code (UFC) , and other local ordinances and regulations . Plans are conditionally approved as submitted, subject to the following items: 1 . Door #201 (new) appears to match section marked "Door Types" , and door #201 in the door schedule is listed as a 20 minute fire rated door. Door #209A is likewise listed as a 20 minute fire rated door. Although not indicated on the plans, this tenant space appears to open out or into a 1 hour fire rated corridor. If this is, in fact, the case, each of these doors and frames must be a 20 minute smoke and draft approved assembly of an approved type. Each must be equipped with approved automatic closing devises . 2 . The wall section between the two doors mentioned above would then, of course, have to be of an approved 1 hour Ce fire resistive design for corridors . Generally 5/8 inch sheet rock on both sides of metal or 2 X 4 's wood r framing 16 inches on center will suffice. t- 3 . One set of approved plans bearing the stamps of the building department issuing the construction permit and this office must be maintained on the project site -� throughout all phases of construction and must be made available to building and fire inspectors for reference during required constructio,-i inspections . UBC Sec . 303 "Working"Smoke Detectors Save Lives c I Ankrom Moisan Architects June 12, 1991 Page 2 4 . Prior to the use and occupancy of the project (space) , a certificate of occupancy or other written instrument of approval must be obtained from the building department issuing the construction permit. UBC Sec. 307 5 . Inspection and approval of construction by a representative of this office is required: (a) prior to the cover of any new framing elements following the installation of: all utility runs which will he concealed within wall and partition cavities; (b) upon completion of construction and prior to occupancy of the tenant space. UBC Sec . 305 If I can be of any further assif3tance to you, please feel free to contact me at 526-2517 . Sincerely, Jerry Renf Deputy Fir Marshal JR:kw cc: Tigard Building Department CL 0 ►- ti J c_7 W J