Loading...
9426 SW WASHINGTON SQUARE ROAD STE 500 COW < ■ FL E 4� >J 6 fo ;Z, actix Inc . Tenant Improvement at ONE EMBASSY CENTRE ,ii1le"Nal, VICINITY MAF' E 2! > 0) TiGARD OR �. Vancouver B 0 1= 5 ID r j:0 C CL = Lu I U M b -4 ° - BUILDING INFORMATION SYMBOL LEGEND TEAM MEMBERS du DESCRIPTION OF WORK: TENANT IMPROVEMENT to Portland BUILDING ADDRESS: 9020 SW WASHINGTON SQUARE RD. Owner TIGARD, OREGON 97204 Client 84 Troutdale NO. OF STORIES: 5 DETAIL Client WYSE WEST OU SERVICES COWAW MW WESDABT ()�:rUPANCY GROUP: B X DETAIL REFERENCE MARKS tT�� BERVICES OMPAW BUILDING TYPE: 11-FR (FULLY SPRINKLERED) NUM �)I`IILL r contact: Andrew James 10 IMPROVEMENT AREA: 3,531 SF Ill SW 5th Ave, Suite 1100 IN SW ft Ave. Beaverton OCCUPANT LOAD (PER TABLE 10--A) : 35 OCC' Portland, Oregon 97204 SWE I= lvlilwau4 it! ACTUAL OCCUPANT LOAD 'EMPLOYEES) 21 OCC tel: 503.294-0400 PORILAM, OR 97204 2 GROSS BUILDING AREA: 91,290 SF KEYNOTES fox: 503.227-2 507 PH (51M) 29+04W � KEYNOTE BUBBLE MARK FAX (51W) W-=7 :� Tig MAP & LOT NUMBER 151268C 01506 Architectect Tualatin Lone Oswego Clackamas ZONE MUC (MIXED USE COMMERCIAQ ROOM NAME PROJECT OFFICE,- LOCA nO.N ROOM/SPACE IDENTIFICATION EEZQ�_RO�OM � GROUP MACKBEE NOTE: BUILDING SQUARE FOOTAGES FOR CODE ANALYSIS ONLY, contact: Kiersten Morgan NOT TO BE USED FOR LEASEABLE AREA. DOOR SYMBOL NUMBER CED 0690 SW Bancroft St Wilsonville PO Box 69039 Portland, Oregon 97239 tel: 503.224.9560 fox: 503.228.1285 GENERAL NOTESContractor r _ - --- Project MOM CREST STRUCTURES GENERAL SPECIALTIES MECHANICAL contact: Alan Volm Taicti)� Inc. 1. Not Ubt� 15. Application of materials by any subcontractor to surfaces existing 25. Fire Extinguisher Requirements: Not less non one (1) approved 50. Tenant space to have full fire sprinkler coverage per UBC and 7233 Kable Lane #900 One Embassy Cw.tre or provided under this Contract shall imply acceptance and fire extinguishers) with rating of not less than 2A1OB:C shall be all applicable codes. Reuse existing as feasible. "0 5W 2. The cl:awings locate products, surfaces, and materials and the notes suitability of existing conditions. Such subcontractor shall be held provided: One "A unit minimum for each 1,500 square feet of floor 51. Firestop, continuous around all new duct penetrations. Portland, Oregon 97214 essentially convoy design intent. The project intent is to provide for responsible for domag- or Irregularities to his product as a result of area or fraction thereof. The travel -istance to an extinguisher 52. The Mechani-ni Contractor shall always confirm BTU heat tel: 503.968.8949 a complete, won g model. Upon completion, all utilities should previous conditions. from any portion of tire building shall not exceed 75 feet. generation on L,.y of the tenant's equipment, Including office be connected ane ali penetrations through exterior walls and roof 16. Contractor shall verify all existing utilities such its sanitary and UFC Stanef-rel lr?-J. equipment, copier-3, rite. fox: 503.598.6658 9= SW Wa*&Von should be water ..jht. storm sewer, water, natural gas, and electrical lines. Contractor 53. The Mechanical Contractor at completion shall prepare and submit &We Road 3. All -orkmanship and materials shall conform to the latest adopted shall verify existing electrical service and shall provide additional (3) copies of an Air Balancing Report to the Architect for rev,'nw. buildin-I code -Jition, arid to conditions and specifications of all service as required. Tt" OrSOM 97= govemi,ig a­.noritles. Contractor shall provide all necessary testing 17. All additional drawings and specificuttons required for permits to FINISHES 5A. All gas piping to be indoors. SHEET INDEX cii. 11 coe-rdl.,ate all required Inspections. be supplied by Contractor and subcontractor(s). 26. Where all now partitions abut, join or connect to existing surfaces, 65. Duct all exhaust fangsepo.otely. 4. Controc+ r shall field verify all dimensions and conditions prior to 18. Contractor to provide mechanical, e4ctrical, plumbing and walls, or new construction the finishea surface shall be aligr-,!d flush. 56. Toilet rooms shall be provided with a mechanically operated startinc L-onstruction and report any discrepancies to the Architect. fire protection as-built drawings, all warranties, and 27. All new walls, partitions shall have taped joints- (3) coats sanded exhaust system capable of prcvfdlng a complett- change of air T1.0 TITLE SHEET Any co.rection work required as a result of not reporting such operating manuals to building Owner within two (2) weeks and primed to meet point-ready requirements. every 15 minutes. Such systems shall be vented to the outside air SOIJ) SITE DIAGRAM discrepancies shall be performed at no additional cost to the Owner. of completion at Work. Contrc.ctor also is to provide Final 28. Prepare all new walls for the Installation of wall covering and point as and at the point of discharge shall be at least (5) feet from any A2. PLANS AND SCfitDULES 5. Contractor and subcontractors shall carefully examine the site and Certificate of Occupancy. No retainage shall be released until appropriate. Comply with manufacturer's Instructions for all Installations openable window. OSSC, Section 304.5. A8.1 DETAILS DEFERRED 3634 the construction documents of the Work. Errors and omissions in Owner has received these Items. of wall finishes. Fire Sprinkler KIR MORGAN the plans or specifications shall be called to the attention of the 19. All materials and products used on the job site shall be 29, Dispose of al! point materials off site, Do not pour down drains, ELECTRICAL Fire Alarm Architect prior to submission of bid so that addenda may be iss�ed. environmentally safe." Use of any product not complying with catch basins, or In 1,indscopling. 57. Egress lighting, exit nigns, home & strobes shall be provided as req'd Mechanical 0 Failure to do so on the part of the Contractor does not relieve the above criteria shall be coordinated with the Architect. 30. Provide a full gallon of each wall color point with labels In approved by code' DEFERRED SUBMITTALS Plumbing PO AND 0 Contractor of the responsibility to provide a correct and finished 20. Contractor will be held responsible for any damage or cleaning location, label all leftover point, and store as directed by Owner 58. Electrical Contractor shall verify the serviceability and reusability Electrical product. throughout structure deemed to be a result of his/her work. ' 31. All exposed gypsum board to be taped and sanded Ath texture to of all existing electrical equipment and repair or replace as Ir 6. General Contractor to coordinate Architectural drawings with Cor.(ract will provide construction cleanup of all areas affected match existing adjacent surface in building (UNO). necessary. Truss Etigineering Mochan;--al and Electrical D/B drawings. All mechanical equipment, by dust or any construction material during construction and 32. All finish materials to be established by Owner (UNO) 59. Electrical Contractor shall verify the lighting design on the reflected FIRE SPRINKLER PLANS Shop Drawings OF ductwork, grilles and registers furnished by Mechanical upon completion of project. Color in accordance with finish schedule as approved by Owner. ceiling plan meets code & tenant needs. Modify the layout as -eq'd. • HVAC & ELECT. DESIGN BUILD DOCUMENTS Other Contractor. All demolition of mechanical equipment, piping, etc. to 21. All demolition work to conform to current OSHA standards. 33. All flooring (carpeting, vinyl goods and metals) shall be 60. All amoke detectors to be in good working condition. be performed by Mechanical Contractor. Provide adequate bracing on existing ceiling framing system prior provided and installed by general contractor or sub. 61. Telecommunications system by Tenant. Contracts- to coordinate 7. Dimensions take precedence over scale. Dimensions are typically to demolition. 34. Contractor to fill and patch existing concrete slab and shell provide work. Verify with owner locations of all new outlets prior to GROUP MACKENZIE 2004 to face of structure ord framing unless otherwise noted. 2_2. Use of elevator permitted only during non-bisiness hours. (6 pm-7am) smooth uniform surface prior to new floor covering to be Inistalled. installation. ONE EMBASSY CENTRE FIFTH FLOOR ALL RIGHTS RESERVED 8. Salvage all removed doors, frames, & relites for reuse. Coordinate Use of loud noise generating machinery permitted only during non- 35 All insulation Indicated on plans shall comply with or exceed 0e 62. A minimum of (2) receptacles & (2) data outlet., required In each THESE DRAWINGS ARE THE PROPERTY OF location with owner's representative business hours. requirements in section 707, ubc for smoke density and flame Dread. private office & conference room. NTS GROUP MACKENZIE AND ARE NOT TO BE 9. Contractor shall keep roofs free of debris (i.e., nails, screws) at all 36. Carpet must Include a CRI-IAO green label Indicating carpet date USED OR REPRODUCED IN AN) MANNER, times and shall be responsible for Immediate repair of any DOORS with Industry standards and Is "environmentally safe* and low odor.* M/E/P WITHOUT PRIOR WRITTEN PERMISSION damaged roof membranes or surfaces. 37-48, Not Used 10. Owner shall not b63. Design-build con�ractora shall design io meet tenant provided standards. e responsible for tools or material goods stolen or 23. Doors shall open from the inside without the use of a key or any damaged on 9!te. 64. Light and ventilation not Indicated on these plans shall be provided AREA OF WORK SUITE %%0 REVISIONS: 11. Upon completion of Work, the Contractor fihall thoroughly clean speclul knowledge or effort. Section 1004.3. Provide sign stating the promises and wash the inside of all windows so that space is "door •shall remain unlocked during business hours" per section FURNISHINGS as per section 1,203 of the ubc. Z 0 NO 65. D/B Contractors shall obtain all req'd Permits & Inspections for their < REVISIONS REVISION DELTA ready for occupancy by Owner. 1007.2.5, ubc on all locking entrance doors--coordinate with 49. Furniture Indicated on plans Is for reference only and shall be ml- portion of work. >_J THIS CLOSING DATE Ld W 12. All substitutions shall be submitted to and approved by Architect, door schedule. considered NIC. SHEET prior to implementation. 24. Contractor shall verify compatibility of hardware specified with 13. Any subcontractor-designed items to be submitted to and approved building keying system. Keying of all door locks shall be in writing by the owner prior to construction. coordinated through the owner. All hardware shall comply w/ADok. 14. Not Used 24a. Glass used In doors or glazing located within a 24" arc of the nearest vertical edge of a door or in areas subject to human Impact or other hazardous locations shall be tempered or of an approved safety glazing material per section 2406, ubc. r e�}- +-- - -- _ ABBREVIATIONS AB ANCHOR BOLI COL COLUMN FD FLOOR DRAIN ISF INSIDE FACE OHD OVER HEAD DOOR 5 TO STANDARD AC ASPHALTIC CONCRETE CONC CONCRETE FOC FIRE DEPARTMENT CONNECTION IE INVERT ELEVATION OPNG OPENING SUSP SUSPENDED TMSHEET TITLE-E SH: EE7 ADJ ADJACENT CONN CONNECTION FIN R_R FINISH FLOOR INSUL INSULATION OPP OPPOSITE L�I I '� JF TIGARU AFF ABOVE FINISH FLOOR CONST CONSTRUCTION FYA GR FINISH GRADE INT INTERIOR O/S OUTSIDE I/ TOP OF 0 3 ;Poe, THK THICK(NESS) Approved.t Wk:pllj(c .............. ALT ALTERNATE CONT CONTINUOUS FLR FLOOR ALUM ALUMINUM CORR CORRUGATED(ION) FOC FACE OF CONCRETE JST JOIST It PLATE T/RF TOP OF ROOF (FRAMING) - _, .3nditionally Approved..................... i I LRF ar o0� the work a ANOD ANODIZED CSP CONCRETE SEWER PIPE FND FOUNDATION JNT JOINT PLAM PLASTIC LAMINATE TS TUBE STEEL -s described in: 76 PEHMITN( .11UZ10 Y 1.0 APPRix APPROXIMATE CNTR CENTER FOIC FURNISH BY OWNER LL LIVE LOAD PLYWD PLYWOOD TU TILT-UP Soo Letter to. Follow-.... ARCH ARCHITECT(URAL) INSTALL BY CONTRACTOR MATL MATERIAL PVC POLY VINYL CHLORIDE TYP TYPICAL I Alta ch.__.. DBL DOUBT FOS FACE OF STUD PVMT I & X. PAVEMENT MAX MAXIMUM B/ BOTTOM OF OF DRINKING FOUNTAIN FOW FACE OF WALL MECH MECHANICAL PT PRESSURE TREATED UL UNDER WRITERS LABORATORIES ate, BD BOARD VIA DIAMETER FT FEET/FOOT MFD MANUFACTURED R RADIUS U/S UNDERSIDE BTWN BETWEEN DVAI DIMENSION FTG FOOTING MFG MANUFACI URING RAD RADIAL VERT VERTICAL - ------ 21 DG BUILDING DL DEAD LOAD MGR MANUFACTURER RD ROOF DRAIN VEST VESTIBULE DRAWN BY: APW BILK BLOCK ON DOWN GA GAUGE BLKG BLOCKING DR DOOR GALV GAI.VANIZED MH MAN HOLE REF REFERENCE BM BENCH MARK DS DOWNSPOUT GEN GENERAL MIN MINIMUM REINF REINFORCING W/ WITH CHECKED BY: KCM BOTT BOTTOM DWG DRAWING GR GRADE MISC MISCELLANEOUS REQ REQUIRED WC WATER CLOSET L___ --- BRG BEARING PLATE 0 YP BD GYPSUM PC,/,RD MK MARK REV REVISION WD Woof) SHEET: EIFS EXTERIOR INSULATION MO MASONRY OPENING RM ROOM W/o WITH OUT 0-T-C CS CATCH BASIN FINISH SYSTEM HB HOSE BIBB RO ROUGH OPENING WP WATER PROOF Occupancy Type CI CAST IRON ELEV ELEVATION HC HOLLOW CORE ROW RIGHT OF WAY WR WATER RESISTANT Occupilocy[.and NIC NOT IN CONTRACT I CJ CONTROL JOINT ELECT ELECTRICAL HOP HEADER NOM NUMBER SHTG SHEATHING WWM WELDED WIRE MESH Construction Type q_ CENTER LINE EO EQUAL HOW HARDWARE NOM NOMINAL Sim SIMILAR WH WAFER HEATER Rated Corridor Yc> T1,10 CLG CEILING EX!ST EXISTING HM HOLLOW METAL NTS NOT TO SCALE SPEC SPECIFICATION Vncrg� Code I" NEN f�1461k/-f CLP CLEAR EXP JT EXPANSION JOINT HORIZ HORIZON TAI SO SQUARE Acce.isihil,Uy Coff 1rue"s CURRUGATED METAL PIPE EXT EXTERIOR HTG HEATING O/A OVERALL SS STAINLESS STEEL CMU CONCRETE MASONRY UNIT FACE STUD FACE OF STUD HVAC HEATING, VENTILATION AND OC ON CENTER STA PT STATION POINT CO CLEAN OUT AIR CONDITIONING OD OUTSIDE DIAMETER Washinaton SQ.Rd.#500,9020 BUP2004-00207 JOB N i of 4 0- 2040057.01 PERMIT SET : 05/05/04 _ -1 ` OFFICE COPY ]CE, 14LI III II L NOTICE: IF THE PRINT OR TYPE ON ANYI I I I 1 1 I I T8 101 L� _.Y T- IMAGE IS NOT AS CLEAR AS THIS N01 No,38 IT IS DUE TO THE QUALITY OF THE ORIGINALDOCUMENT Z (( IIIIiIIII IIIIIIIII�IIT 11 Ll 9 ti, , 111 Z 11 1111 1 �II I Ili,,I t —� C4 CAP r dC FYI I cy a �- QD lIlr1 oa Q� P�' -- PENN / PARKING STRUCTURE > : W l - Client 4' 4' 9' - - ' 263'--O' / WYBE CVVES'Ttu�NT x -- - --- E �_ - SERVICES COMPANY M SW�� --- -- sun ttt00Ave. - - — PORTLAPID, OR 97204 ----- PH (500) 294-0400 FAX (500) 227-2507 - I - i I o Project N TactbX Inc. One Embtauy Centra Suite 500 9020 SW Waditton Square Road \� `. T%Wck Or"m 97223 - - L r , I 364 KIER ROAM PO ND, OR tl 1 SITE DIAGRAM - NOTE: THIS PLAN IS SHOWN FOR REFERENCE ONLY (NO EXTERIOR WORK IS PROPOSED) -- --=- G MACKENZIE 2004 1" - 20#-01'� 0 AOL RALL THESE DRAWINGS ARE THE PROPERTY OF GROUP MACKENZIE AND ARE NOT TO BE USED OR REPRODUCED IN ANY MANNER., WITHOUT PRIOR WRITTEN PERMISSION REVISIONS: Owner/Applicant SITE INFORMATION o NO �Q REVISIONS REVISION DELTA j~1 THIS CLOSING DATE Ld U1 sHEE r WYW NVEBTMIffiT SEFNKMS 00WANY TAX LOT: 1 S1 W26BC01506 ZONING: MUC contact: Andrew James 111 SW 5th Ave, Shite 1100 PARKING: 2.33 STANDARD SPACES Portland, Oregon 97204 7 HANDICAPPED SPACES tel: 503.294-0400 —� fox: 503.22.7-2507 SHE TITLE: SITE aRAM DRAWN BY: APW CHECKED BY: KCM SHEET: SD1 .0 Washington Sq.Rd.#500,9020 F BUP2004-00207 2 of 4 JOB No. 2040057.01 -11 PERMIT SET : 05/05104 CH\01-Sb10.DW0 APW 05/05/04 1$ +s NOTICE- IF THE PRINT OR TYPE ON ANY I I I III III III III l 1 III I I IIIIIII I I I A I I I1111 I 11TIT TI-1I 1[I 1 1 1 1 1 i 1 1 Ill I I I 1 1 1 1111 111 1 1 1 111 1 1 1 1 I III 1 1 1 1 1 1 1 1 1 1 1 1 I I I I I I I 1 11 11 t l I I l l 1 J l I l l l l 111 I I I I I I I I I 111 1 1 I 1 I I I ^I l t 1 2I 3 4 5 - -- ll ------- 1 - _ 1----- -� ----- - -� _�� IMAGE IS NOT AS CLEAR AS THIS NOTICE, -_ � _�.1_ _�__-__ �� No 36 IT IS DUE TO THE QUALITY OF THE ORIGINAL DOCUMENT LZ 9Z sz bZ I sz Z 1Z o1z et 8i GT 9i 9t ib�[ sT tit T111[�[t11111111 �1141 gIId1li11�IIIIlllllll1U1Il11�vl 1110 1.1�1LI� IIIIINII j IIIIIIIIIIII�llil111�IIILIIIIi�II Il,illi�il�fl�ll�lll��l ,III II I . IIII I III ill IIII II� I�IIII II lll� III IIII�IiI IIII ll�l�l III (111 IIII lll t 1 1 .9 2.5 3 4 5 1 1 .9 2.5 ; 4 3 .R 5 . E E r'0' 0" 20'-Qv � 11r-Q" d � n - Z 4D 0 Q7 G - 10 -1Q 9 -10 20,-0„ 20' 0 , ___... ' ® �- ev -_ - - ----- - -- _ T �- I -, DEFT ICEOFF ICE N 5U 504 I ► I `r > co a CL a 11 I + Cl- „ �7 LVE(0�1 E + - - + -- _ a + + + i - - _ - - ��5 50 5 � � - - - - - {i j � 502OL o c( - Lu � ci JL + + + - -- -- -- + + 13 + f > tom' 6. �7 t + y 0, 5 - ,y OPEN a- 0 �, - ---- +�� j bl' OFFICE f , 5 - - _ --� = - - - - - - - - - - - I� c - - - - ,r - 1 501 _ - i - Client ' OPEN ' 7 R j { OFFICE - + N UVYBE �� NT d I= 5Q1 nPP Ir1:6N,CE e ;! l I ,,. PANY d i I 7 - R' + + R'. + �;; + + R + POR'TL.A O, OR 97204 i -- -- -- _ 'a A8.1 94-0400 G - -- -- - FAX (503) 27 F.5 - -- - - - 5 $ .t CA �- F.5 _..� _ - - - - I R o + CIA P-2 x M A _ � -. � r 12 30A 20A 20A 220A o Q CPT 3 ull 5 06 i + + - R - + 9- - R m r, a 6 �. 20 r (fi rJ OI R + 5 6 °� 20A 30A 30A 20A 30A t 7 D 20 VCT o 4 (1) I+.a - r - I A8.1 (1) FOR b 2 - "� Project ` + ® Tadix, Inc. One Embaes 4'-0" '� ,• `R � � _ y Centre CL CORRIDOR ' ' quite 500 5018 1 -6 500 rj -+ S + I CLR O 50 9020 SW Wa&Anoon oerz Square Road 10 __ ®____-- - I%Wc, C*egm 97223 7 17 r FLOOR PLAN _ -- ♦ 2 REFLECTED CEILING PLAN A21 1/8"=v-o" GD 0_ �� a C 3634 KIER ORGAN KEYNOTES GENERAL NOTES Doo POR _ R SCHEDULE FINISH SCHEDULE o No, OR NOMINAL SIZE 1. ALIGN DEMISING WALL w/ EXISTING CORRIDOR WALL AS SHOWN A. REUSE EXISTING OUTLETS AS FEASIBLE WIDTH HEIGHT DOOR TYP HARDWARE REMARKS ROOM FLOOR BASE N. WAts E. WALL S. WALL W. WALL CtILING CEILING ROOM NAME MATERIAL MATERIAL. MATERIAL MATERIAL MATERIALMATERIAL REMARKS2. CENTER DEMISING WALL ON COLUMN GRID B. MATCH BUILDING STANDARDS IE FINISHES, FIXTURES, DOORS HEIGH( N0. FINISH FINISH FINISH WISH FINISH FINISH FINISH3. 24HR HVAC FOR T!1IS ROOM AND ETC), TYP 501A 3'-0' 8'-0' A LOCK 1, 2 4, 51,#ATERIAL - 4. NEW UPPER AND LOWER CASEWORK WITH SINK AND DISHWASHER C. DOORS ARE EXISTING TO REMAIN, UNO 5018 3'-0• 8'-0' B LOCK 1 4 500 CORRIDOR CPT Re Gs s GB Gs SAT 9'-0' DOST 1 4 502 3'-0- 8'-0- C PASSAGE 3, 6 GROUP MACKENZIE 2004 SEE 8/A8.1 D. ELECTRICAL DESIGN/BUILD CONTRACTOR TO COORDINATE AND 501 OPEN OFFICE CPT Re Ge P -',8 Gs GB SAT 9'-0' EXIST 1 2, 3, 5 © ALL RIGHYS RESERVED DOOR NOTES 502 CONFERENCE CPT Re GB Ge Ge GA SAT EXIST 1 2 3 THESE DRAWINGS ARE THE PROPERT r OF 5. NEW UPPER AND LOWER CASEWORK (7'-6" LONG) AT COPY/FAX CONFIRM ELECTRICAL REQUIREMENTS w/ TENANT REPRESENTATIVE 503 OFFICE CPT Re Ge GB ce GB SAT 9'-0'EXIST 1. 2. 3 GROUP MACKENZIE AND ARE NOT TO BE SEE 9/A8.1 504 I)MCE CPT Re GB Gs GB GB SAT V-0' DQST 1 2 3 USED OR REPRODUCED 1N ANY MANNER, 6. PROVIDE ELECTRICAL FOR TENANT SUPPLIED REFRIGERATOR 505 OFFICE CPT Re GB Ge GB SAT 9'-0' DGST 1, 2, 3 WITHOUT PRIOR WRITTEN PERMISSION 1. 20 MIN DOOR �A / `�� '<<4� 506 SERVER VCT Re GB Ge GB GB SAT 9'-0' pQST 1 2, 3 7. PROVIDE POWER POLES FOR TENANT SUPPLIED SYSTEM 2. 1'-6" FULL HEIGHT RECITE, SEE 5/A8.1 REVISIONS: FURNITURE; COORDINATE INSTALLATION w/ FURNITURE 3. 3'-0" FULL HEIGHT RECITE, SEE 5/A$.1 CPT CARPET z NO VENDOR 4. SOLID WOOD DOOR, STAINED TO MATCH (ADJACENT) ENTRY DOOR EXIST EXISTING o� REVISIONS REVISION DELTA 8. PROVIDE POWER FOR TENANT SUPPLIED COPIER 5. PROVIDE WIRED GLASS IN DOOR, SIZE TO MATCH ADJACENT ENTRY DOOR GB GYPSUM WALLBOARD �_J THIS SHEET CLOSING DATE 9. ADJUST EXISTING LIGHTS FOR NEW TENANT LAYOUT, TYP 6. SOLID WOOD DOOR, STAINED TO MATCH (ADJACENT) OFFICE DOOR P PAINT 10. NEW RATED "TUNNEL" CORRIDOR WALLS AND DOOR, SEE 10/A8.1 RB RUBBER BASE 11. FLOOR MOUNTED OUTLET 12. PROVIDE CENTRAL MODEL WS, 5.6 K -FACTOR FIRE SPRINKLER SAT SUSPENDED ACOUSTICAL TILE HEADS 0 EITHER SIDE OF RELITE VCT VINYL COMPOSITE TILE 13. NEW HORN STROBE LOCATION DOOR TYPES FINISH NOTES T TEMPERED GLAZING 1'-6'^ " 3'-0" 1. EXISTING CEILING TO BE REPAIRED / REPLACED AS REQ'D 9 *-_-_ BY NEW WORK. ---- -- 2. SEE PLAN FOR ACCENT WALL PAINT LOCATIONS - - 3. SEE FINISH MATERIALS MEMO FOR FINISH SPECIFICATIONS SHEET TITLE: o � T T � T `•� 4. MATCH EXISTING CORRIDOR FINISHES 1 5. SEE PLAN FOR LOCATION OF VCT (SEE 5/A8.1 FOR START OF 2'--0" - - i VCT LOCATION, AS OCCURS) -- - - A -�--*' B C LEGEND ------ ITEMS TO BE DEMCLISHED STANDARD 18 CELL 2 x 4 E} NEW/RELOCATED DUPLEX OUTLET, ® 18" AFF, UNO E-iSTING SUSPENDED ACCOUSTICAL URAINN BY: APW FLORESCENT LIGHT FIXTURE - CEILL IG, REPAIR AS REQ'D, SEE EXIST. WALL TO REMAIN TO MATCH EXISTING, (. OF NEW 30A ELECTRICAL OUTLET, (E 0 18" AFF, UNO 7/A8.1 FOR BRACING INFO. CHFCK_ED BY: KCM EXIST 1--HR RATED WALL TO REMAIN LIGHT SWITCH ® 44" AFF Q NEW/RELOCATED TELEPHONE/DATA OUTLET SHEET: ® NEW 1-HR RATED CORRIDOR WALT_, STANDARD 9 CELL 2 x 2 IJPP NEW/RELOCATED POWER/DATA POLE SEE DETAIL 10/A8.1 FLORESCENT LIGHT FIXTURE NEW SUSPENDED ACCOUSTICAL CLG; TO MATCH EXISTING, � OF ® NEW BASE FEED ,, ;rf' . SEE 7/A8.1 FOR BRACING INFO. NEW WALL, LIGHT SWITCH ® 44" AFF ; , AND 10/A8.1 FOR TUNNEL INFO. A281 + FIRE SPRINKLER, EXISTING UNLESS NOTED OTHERWISE SEE DETAIL 1/A8.1 RECESSED CAN LIGHTS (CENTER ON 2x2 PORTION OF CLG TILE) EXISTING SMOKE DETECTOR WashinBUP 004-0 #500, 9020 BUP1004-00207 2004-00207 3 of 4 HVAC SUPPLY/RETURN =D HORN STROBE, EXISTING UNLESS NOTED OTHERWISE O NEW EXIT SIGN JOB NO. 2040057.01 ® EXIST FIRE EXTINGUISHER PERMIT SET 05/05/04 NOTICE: IF THEPRINTORTYPEONANY II+(+ II� 111 III II . II ' SII I + III if II III I r III III r�TT rlr III III I I III III ilI III III Ili illi I SII Ili 1lr rC7 ►�r�rll 111 i i Ili Ili Ili 11 , Ili Ili ilillll 1lI I ; i � lili i IMAGE IS NOT AS CLEAR AS THIS NOTICE, Z � I � � 4 I -�I - I 61_ --�I- - �1.-- -- �. ---$l ---_� � �0� -- -� 11 � 1�1 ,,)dJLA(I IT IS DUE TO THE QUALITY OF THE Na 36 / ORIGINAL DOCUMENT ��E sffz t3�zI �Lz 9z �z91 6T sai tit t"[ t 6 8 L 9 9 E -fT� jiY17N ? IIIIIiiI�IIIIIIIIi�IINlllllllllllllll I�I I �il Ii lilliilili � IiIIIIIIIIIIIII�IiIIIIIII�IIIIIIII� II, ILII�II I1i111 I �i I Ili Ii�lll�lllllllil�lllllllll�illi i I� II II � I � I � i Illi IIIIIIIII�IIIIIIIIIIIIII�tllllililllllllflflflllllll�II� W lII 11 LI IlIll . J �� II II I I � ll I l l l l Lllll�lllll�lll ATTACH STUD TRACK �► aC � DIRECTLY TO GRID 3 Ln SUSPENDED CLG \ Q -w ASSEMBLY aia L E � 0 T"— _ _ _ SOUND ATTENUATION BATT D 7) 45. _ INSULATION ® CORRIDOR a .� 2 AND DEMISING WALLS !� AS.1 EXISTING SUSPENDED CEILING, � 20 GA 6" METAL STUD BRACING { ( ___._------'WALL AS OCCURS "� •� � REPAIR AS REQ D, BRACE TO WALL PER DETAIL ,f TO STRUCTURE AT 8'-0" oc w/ '2) #8 SHEET METAL SCREWS AT - 1 J EA END. BRACING TO BE PROVIDED - DBL STUD AT JAMB TYP _ CASING BEAD -- �A - USG 200-A WHERE DISTANCE BETWEEN - ---- - -- -- PERPENDICULAR INTERSECTINGaC > � 1 ` WALLS OR HORIZONTAL BRACING _ 7 r " -_ -�_ PT/VCT TRANSITION 4D w EE PL NS FOf�' BETWEEN WALLS EXCEEDS 8 -0 oc GYP BD PAR TITION SEE PLAN m WALL T f'PE AS SHOWN ON PLANS TIMELY HOLLOW MTL KNOCKDOWN i & THIC'CNESS FRAME; MATCH BLDG STD r y' PROVIDE SOUND BATT INSULATION ® LINE OF SILL AS OCCURS {y 0 LOCATIONS NEW DEMISING, CONFERENCE ROOM 2 WALL TO SUSPENDED CEILING o -- - ---- - - - - -- ---- 1NDICATED20 MIN AONDD OR SCHEDULE) E ; , �� ►� -: AND BREAK AREA WALLS - ---- — ---------- _ _____.__ ___ _. �. .. _ / 7) -� TYPICAL. 3 = 1 -0 ►- A8.1 E_ E PLANS FOR p ALUMINUM CLOSER SHAPE WALL TYPE TO MATCH STOREFRONT W/ OR 3 MATCH EXIST 20 GA MTL & THICKNESc 1-1/4 RETURNS TO MATCH _— " +d t , � - J • STOREFRONT FINISH -. UDS 0 24 oc w/ % TYPE X GYP BD - _336OR 3%" (MATCH EXIST), EA SIDE, ATTACH GYP BD TO STUDS ® BOTTOM TRACK TO FINISH 20 GA MTL STUDS ® 24" oc 12." oc MAX FLOOR WITH POKER DRIVEN '-� w/ %" TYPE 'X' GYP BD EA SIDE Z Client ANCHORS AT 48" oc \ CONT ACOUSTIC SEALANT 0- N� EA SIDE AGAINST TRACK w — �) W M Ave mS S ICEES COMPANY Ld NEOPRENE SEAL _ TEMPERED RECITE AS OCCURS W/ 100 - 3 1 ,12' MAXI- ' w_/ -- - MFR'S STANDARD GLAZING STOP OR 97204 CUT THE TAPER OFF GYP BD `� 1 STOREFRONT GLAZING (5W) 29+04W AT WALLS WHICH RECEIVE l� CONCRETE SLAB SYSTEM FAX (W) 2V-2W7 FLAT BASE, SEE FINISH SCHEDULE - Q 3 NON—BEARING WALL AT FLOOR 4 WALL AT MULLION - 5 DOOR/RELITE JAMB INTERIOR WALL TO CEILING �8. 3/4"=1'-0" A8.1 3" = 1'-0" a Age 3" = 1'-0" a Ag.� TYPICAL AT INTERIOR, HEAD SIM 3' = 1'-0" o Z 3 3 z FLOOR OR ROOF STRUCTURE STABILIZER BAR BETWEEN ALL MEMBERS } AT PERIMETER -ADDILIIONAL HANGERS AT ALL h! MBERS WITHIN 8" OF PERIMETER ' LATERAL BRACING WITH APPROVED VERTICAL STRUT - AT 12'-0" O.C. EA. WAY. USE (2) 350 IC 20 BACK TO BACK WITH SCREWS 024' O.C. ALT. 1'-O" 1'-O" P_-- -000NTERSLOPE HANGERS IF MORE THAN 1:6 OUT OF PLUMB Project ALIGN w/ LOWERS - ALIGN w/ LOWERS Tactix, Inc. _ % __ One Embassy Centre E (2) ADJ MELAMINE (2) ADJ Suite�. SHELVES MELAMINE cO _IX SHELVES _.__.. " 9020 8W Wa*ftton 4 SqW io d I - o -- BACKSPLASH � -- -- I c o I w 9 TOWA Oregon 97= NBACK- H, 6 4" c� r----- _ SPLASTYP J �---DRAWERS IDRAWERS ! -. (2) COMPARTMENT CROSS RUNNERS FIT BETWEEN .I 8' MAIN RUNNERS C4 SS SINK DRAWERS N ADJ SHELF ADJ SHELF AIN RUNNERS AT 4'-0" O.C. 3534 ` F, SUPPORT WI f N #12 WIRE AT 4'-,0" ---,�- 6'-0" MAX Q.C. OR WITH #10 WIRE A7 5'-0" 4" H x 3" D � KIE T GAN O.C. EA. WAY LDISHWASHER \\-4" H 3" D " 2'-0" TOE KICK, TYP LATERAL BRACING AT 12'-0" O.C. 8'-7"f TOE KICK, TYP 2 -0 7'-6"� - - / P AN OR EA. WAY MAIN RUNNER TO STRUCTURE - BEGIN BRACING WITHIN 6'-0" Of — (6) EQ SPACES (6) EQ SPACES PERIMETER AND 2 FROM CROSS M_c, .BCR. w/CLR SPACE UNDER SINK 6 �-- ,M 180' HINGES ® v SECURE ALL HANGERS TO BLDG. CAB DOORS;NO KICK ® — -= STRUCTURE. TRAPEZE DUCT WJRK BASE 2004 © AND OTHER LARGE OBSTRUCTIONS. GROUP MACKENZIE ALL RIGHTS RESERVED VEE THESE DRAWINGS ARE 1HE PROPERTY OF SUSPENDEDCEILING BRACING 8 CABINET ELL IATION s CABINET ELEVATION GROUP MACKENZIE AND ARE NOT T4 Be p USED OR REPRODUCED IN ANY MAPJNERr ALL CONNECTION DEVICES TO BE OF AN N.T.S. m 1/4"=1'-0" m NOTE: 1/4"=1'-0" m WITHOUT PRIOR WRITTEN PERMISSION A8.1 APPROVED TYPE AND HAVE 100# CAPABILITY Ag'� Q A81 -- REVISIONS: NOTE: 1. PROVIDE FIRE/SMOKE DAMPERS AT ALL HVAC PENETRATIONS TG' MATCH RATING OF CORRIDOR. BEND STUD No >�a REV�SIONS REVISION DELTA THIS CLOSING DAME 2. PROVIDE FIRE SAF'NG 0 ALL OTHER AND FASTEN w/ K� SHEET PENETRATIONS FOR 1--HR RATING. (2) #8 SMS 3. MODIFY EXISTING CORRIDOR 0 WEST SIDE AS REQ'D FOR CONNECTION w/ COP,RIDOR EXTENSION TO MAINTAIN FIRE RESISTIVE CAPACITY. B 6", 20 GA MTL STUDS; BRACE TO MTL DECK ABOVE 0 MIDPOINTS OF EACH NEW CORRIDOR $ MARCH EXIST~ WALL AND ® ENDPOIN FS Cr EACH NEW SHEET TITLE: G -� CORRIDOR WALL WHERE THEY CONNECT TO \ � DETAILS EXIST CORRIDOR WALLS MATCH EXISTS6", 20 GA MTL STUDS W/ %# TYPE 'X' GYP BD EACH SIDE; SPACING TO MATCH } WALLS SAT CLG; MATCH EXIST -1-HR RATED CORRIDuk WALLS 3,16" OR 3% " (MATCH EXIST), DRAWN BY. APW 20 GA MTL STUDS 0 24" oc 3 w/ TYPE X GYP BD EA SIDE CHECK Y: KCM SHEET: 10 EXIT CORRIDOR__SECTION___ _ __ A801 A8.1 MEET REQUIREMENTS OF WP 1081 1/4" = 1'-0" x W VVashin4ton Sq.f2d.#500,9020 BUP2004-00207 4 of 4 JOB NO. 2040wni PERMIT SET : 05/05/04' NOTICE: IF THEPRIRTC�r*. T'rPEONANY l III III 11 ' III I � I III I III III III I VIII III 1111111 III III III I I III III Ili 111 III Ilillll I I 1111! 11 III 111 ' 111 III III I i III III 1111111 III III IIIIIII ' 111 11 � 1 ' IIII I I I ( I I I I I I I lY I 1� IMAGE IS NOT AS CLEAR AS THIS 'VOl ICE. - il. --Z�- - �..-._ --- L ---- �-- - - - - ��L '-1-- --- ---g� _ "L 10 --- - -- - -..._ �. 0.�..J ITIS DUE TO ----- THE DUALITY OF THE No.39 I► £ ISII i IZI IIZ I�I►II Z Il�li6l�I1Z1►!��ll£lllZlI I I III tiIIIL�IIIiIII7I,IIi�llUl►ltiull IIdII�1 t1lll�llelirltliii�ll►tilli I1111IIIIIIL�I1IttlllotII IlI 111111111IlllluIll-ORIGINAL. DOCUMENT III�II8II IGIIL� 9II 9 1b 11��.111£iu IIl���Zll11II 111�i tI I I I bhl�l l r il� ►►