Loading...
Report EP5 Yr-mool Northwest The Suppression, Inc FIRE ALARM/SUPPRESSION SYSTEM RECORD OF COMPLETION Protected Premise: Owner's Rep&Phone: Cypress 10220 SW Greenburg Road 417 Tigard,Oregon This system was designed by,and equipment supplied by: • Northwest Fire Suppression,Inc., 15385 SW Beaverton Creek Court Beaverton,OR 97006 Phone: 503-644-7720 Fax: 503-644-8289 1. Types(s) of System or Service Control Unit Manufacturer: Fike Other Model Number: SHP Pro ❑ 0 Other(Specify) Type of Communication: []] N/A ❑ Other(Specify) Monitoring Provided By: Building Alarm Account Number: Alarm Code Style: Phone Line 1 Number: Phone Line 2 Number: 2. System Power Supplies (a) Fire Alarm Control Panel: Nominal Voltage: 120 Current Rating: 20 Amps Breaker Location: L a ex-r -77 (b) Secondary(standby): Sealed Lead Acid Batteries 8 AH Providing: 24 Hours Of Backup 3. System Software Panel Firmware Rev#: IV�I Application Software: Rev Completed By: Name Company Page 1 of 3 4.Notification Devices Quantity Device Type Bells Horns 1 Horn/Strobes 1 Strobes Speakers Annunciators Other(Specify) 5. Initiating Devices Quantity Device Type Fire Alarm Pullstations 1 Suppression Manual Release Station Ion Detectors 2 Photo Detectors Duct Detectors Type: Heat Detectors Waterflow Switches/Pressure Switches 1 Abort Switches Tamper Switches Low Air Switches Low Pressure Switch Discharge Pressure Switch 6. Record of System Installation This system has been installed in accordance with the National Electric Code, and meets all requirements of Article 760 as a Power Limited Fire Alarm system. After all device installation was complete(except control equipment final terminations), all initiation, signal and control circuit wiring was tested and found to be free of opens, shorts and ground faults. The entire system was installed per the AHJ approved plans, and complete, accurate "as built"notations have been provided to Northwest Fire Suppression, Inc. Installing Contractor: NWFS Responsible Journeyman: ,� Loch License#: 2755LEA Signature: Date: 5 Page 2 of 3 04. 7. Record of System Operation All operational functions and features of this system were tested and found to be working properly in accordance with the approved plans,per NFPA 70,National Electric Code,Article 760, per NFPA 72, Chapters 1, 3, 4, 5, 6 and 7, and per the manufacturer's instructions. I have reviewed the"as built"drawings and find that they are accurate and complete. Certifying Contractor: NWFS Responsible Journeyman: Dan Loch License#: 2755LEA Signature: - Date: 8. Acceptance Testing Statements Commissioning Technician: I have tested and witnessed satisfactory performance of all system devices and control functions, and/or have noted any exceptions on this Record of Completion. Name: tk an c h Representing: NWFS Signatur • W.:;47 Date: Local Authority(or Authorities)Having Jurisdiction: This system has been inspected and is accepted for the jurisdiction I represent. Name: - /A Representing: Gt..] e94 Signature: _•_ Lisa ����I / / 9. Comments V Page 3 of 3