Report (2) • FPS Zo 070 FIRE ALARM SYSTEM RECORD OF COMPLETION To be completed by the.system installation contractor at the time of system acceptance and approval. 1. Protected Property Information Name of property: f}C(il C •• Address: ,..._ 12,9 el_._ slo (o$" ,..._ 14ttr..1A� Description of property QA.c Tftkis T QF Ft Gts .' lv I L,.D IN/c Occupancy type: _f3 f3 Name ofro p perty representative: l�N �IV I TA r k.A Address: _.._._ ( 53 50 StN 5 E Q V X71 A pk f it~/A-y ofiffoo Phone: (7 5-4z y 6300 Fax: E-mail: Authority having jurisdiction over this property: ( I'r' O 1c o Phone:503 x`719-L(j3 I Fax: E-mail: 2. Are Alarm System Installation,Service,and Testing Information Installation contractor for this equipment: P 1 NT__..1 ION 1T0 Address: _ S.Q(p3 L WE t4.) DLVI) $(HITT 10o Phone: 7-.01_00__ Fax: 50 '''‘,21-01c0 E-mail: Service organization for this equipment 57A/.4t . &jIU V MCeit-Fr Se.CU Ri T' Se LuT10A'S Address: (OtictS. SW re evn to ? s.ttwikY t�1�o �rie,*.o,._ pIZ_ 172z4 Z4 Phone: 503 - roe-•3,330e Fax: • E-mail: Location of as-built drawings: Fier Location of Historical Test Reports: g7AH t.f 7 Location of system operation and maintenance manuals: STAN L Y A contract for test and inspection in accordance with NFPA standards is in effect as of Contracted testing company: STA N L-t'4 C 5S Address: 15915 $W peavolh Pik ttk wPY 1/DO , _..._.... vitvi Phone: �!` ax9-3 300 _.. ---- Fax: E-mail: Contract expires: ..__ Contract number: — - — — Frequency of routine inspections: 3. Type of Fire Alarm System or Service NFPA 72m Chapter Reference of System Type: Ft/I C.D/A,4 Rite _ALA l+K rYS?'E±k 1... t1i4 CEW AAI. Name of organization receiving alami signals with phone numbers(f applicable): .Mi I TA/Wf Alarm: SCAN Lest C S Phone: _._.�77 opt Supervisory: $TAht LEY CSS Phone: __-- Trouble: STANLEY CSS Phone: sI Entity to which alarms are retransmitted: Gnpp 9 s /!s- �J�n_C.__ __-. .��r_C�A Phone: d � Method of retransmission of alarms to that organization or location: DI ,TA L NFPA 72,Fig.4.5.2.1 (p. 1 of 5) Copyright t 2009 National Fire Protection Association.This form may be copied for individual use other than for resale.It may not be copied for commercial sale or distribution. If Chapter 8,note the means of transmission from the protected premises to the central station: , 'Digital alarm communicator 0 McCulloh 0 Multiplex 0 2-way radio 0 1-way radio 0 N/A If Chapter 9,note the type of connection: 0 Local energy 0 Shunt ❑N/A 3.1 System Software Operating system(executive)software revision level: Site-specific software revision date: Revision completed by: 4. Signaling Line Circuits Characteristics ofsignalingline circuits connected to this system(see NFPA 72a,Table 6.6.1): Quantity: 7 Style: Class: 5. Alarm-Initiating Devices and Circuits Characteristics of initiating device circuits connected to this system(see NFPA 72®.Table 6.5): Quantity: .__-... Style: Class: 5.1 Manual Initiating Devices 5.1.1 Manual Pull Stations Number of manual pull stations: t Type of devices: Pg Addressable ❑Conventional ❑Coded 0 Transmitter ❑N/A --5.2 Automatic Initiating Devices 5.2.1 Area Smoke Detectors Number of smoke detectors: Z' Type of coverage: 0 Complete area 0 Partial area kr Nonrequired partial area 0 N/A Type of devices: gAddressable 0 Conventional 0 Coded 0 Transmitter ❑N/A Type of smoke detector sensing technology: 0 Ionization rPhotoelectric 5.2.2 Duct Smoke Detectors Number of duct smoke detectors: �/Z Type of coverage: • Type of devices: Ca Addressable 0 Conventional 0 Coded 0 Transmitter 0 WA • Type of smoke detector sensing technology: 0 Ionization 13 Photoelectric 5.2.3 Heat Detectors Number of heat detectors: 0 • Type of coverage: ❑Complete area 0 Partial area ❑Nonrequired partial area ❑N/A Type of devices: 0 Addressable ❑Conventional 0 Coded 0 Transmitter ❑N/A 5.2.4 Sprinkler Waterflow Detectors Number of waterflow detectors: H.. Ara.._ . 0405 ._t_PFt__ A Type of devices: Qif Addressable 0 Conventional ❑Coded ❑Transmitter ❑N/A 5.2.5 Alarm Verification• Number of devices subject to alarm verification: 0 Alarm verification on this system is:❑Enabled 121Disabled ❑Set for seconds 6. Supervisory Signal-Initiating Devices and Circuits Y lei Self VALY ES _ / rex'FLA 6.1 Sprinkler System Number of valve supervisory switches: 3 gemore lot L V E S ON /n''VO X Type of devices: 'Addressable 0 Conventional ❑Coded 0 Transmitter ❑N/A NFPA 72,Fig.4.5.2.1 (p.2 of 5) Copyright 0 2009 National Fire Protection Association.This form may be copied for individual use other than for resale.It may not be copied for commercial sale or distribution. 6.2 Fire Pump /u Type of fire pump: 0 Electric 0 Diesel Type of fire pump supervisory devices: 0 Addressable 0 Conventional 0 Coded 0 Transmitter ❑N/A Fire Pump Functions Supervised 0 Fire pump power 0 Fire pump running 0 Fire pump phase reversal 0 Selector switch not in auto ❑Engine or control panel trouble 0 Low fuel Other: 6.3 Engine-Driven Generator ,V4 Type of generator supervisory devices: 0 Addressable 0 Conventional 0 Coded 0 Transmitter ❑N/A ❑Engine or control panel trouble 0 Generator running 0 Selector switch not in auto 0 Low fuel Other: 7. Annunciators 7.1 Annunciator 1 irLocal 0 Remote Type:0 Addressable 0 Directory 0 Graphic 0 N/A Location: 'ACI' $V 7.2 Annunciator 2Local 0 Remote Type:D Addressable 0 Directory 0 Graphic 0 N/A Location: esT euT8-Y 7.3 Annunciator 3 0 Local 0 Remote Type:D Addressable ❑Directory ❑Graphic ❑N/A Location: • • 8. Alarm Notification Devices and Circuits 8.1 Emergency Voice Alarm Service AI161 Number of single voice alarm channels: _-T- Number of multiple voice alarm channels: Number of speakers: Number of speaker zones: 8.2 Telephone Jacks NA "Number of telephone jacks installed: Number of telephone handsets stored on site: Type of telephone system installed: 0 Electrically powered 0 Sound powered 0 N/A 8.3 Nonvoice Audible System Characteristics of notification device circuits connected to this system(see NFPA 72®,Table 6.5): Quantity: 2.0 !thG CUt VlTSstyle: _ _— -- Class: 8.4 Types and Quantities of Nonvoice Notification Appliances Installed 113 Bells: SLAM/m"4 With visual device: Horns: *-474--42 With visual device: ye-s: Chimes: With visual device: Bells: With visual device: Visual devices without audible devices: eq.- 2.7 Other(describe): NFPA 72,Fig.4.5.2.1 (p.3 of 5) Copyright®2009 National Fire Protection Association.This form may be copied for individual use other then for resale.It may not be copied for commercial sale or distribution. . e 9. Emergency Control Functions Activated • 'Hold-open door releasing devices rfrSmoke management or smoke control iRt Door unlocking gi Elevator recall ❑Other 10.System Power Supply 10.1 Primary Power Nominal voltage: __ I ZO VAC Amps: Overcun-ent protection: Type: RticA ._._. ..__..__....._Kt'R ___.________ Amps: ______.__ Location(of primary supply panelboard): iT pp/L Et ;L k 4` o K Disconnecting means location: If T FLO OA Et.e t,rNit(..M, 10.2 Secondary Power Location: Type: Nominal voltage: — Current rating: Number of standby batteries: (' f() y/Y.AC P(&Amp hour rating: _15A+3 gyp. Location of emergency generator: Location of fuel storage: Calculated capacity of secondary power to drive the system In standby mode: zy x_....__._ -._--__-.. In alarm mode: /NI N 11.Record of System Installation Fill out after all installation is complete and wiring has been checked for opens,shorts,ground faults,and improper branching,but before conducting operational acceptance tests. The system has been installed in accordance with the following NFPA standards:(Note any or all that apply.) o"NFPA 72® NFPA 70°Article 760 Manufacturer's published instructions 0 Other(please specify): System deviations from referenced NFPA standards: Signed: !',(�(,f(.rj,JW �y �r_ ..._.__._.._ Printed name. ray Date Organization: O / 'Nom Title: 3-.319...__74 1 P _..._Z�'r,N. __._._._._._.—___._...- --- Phone: .. 12.Record of System Operation All operational features and functions of this system were tested by or in the presence of the signer shown below,on the date shown below,and were found to be operating properly in accordance with the requirements of: ❑NFPA 72° 0 NFPA 70®,Article 760 ❑Manufacturer's published instructions - 0 Other(please specify): ❑Documentation in accordance with Inspection and Testing Form(Figure 10.6.2.3 of NFPA 72°)is attached Signed: _`.__....— Printed name: Date: Organization: • Title: Phone: NFPA 72,Fig.4.5.2.1 (p.4 tot 5) Copyright 5 2009 National Fire Protection Association.This form may be copied for Individual use other than for resale.It may not be copied for commercial sale or distribution. 4 - t 13.Certifications and Approvals • 13.1 System Installation Contractor This system as specified herein has been installed and tested according to all NFPA standards cited herein. Signed: _—__�---...__.___ Printed name: Date: Organization: _____ Title:Title: Phone: 13.2 System Service Contractor This system as specified herein has been installed and tested according to all NFPA standards cited herein. Signed: Date: Printed name: Organization: Title: Phone: 13.3 Central Station This system as specified herein will be monitored according to all NFPA standards cited herein. Signed: Printed name: Date: Organization: Title: Phone: 13.4 Property Representative • I accept this system as having been'installed and tested to its specifications and all NFPA standards cited herein. Signed: Printed name:' Date: Organization: Title: Phone: 13.5 Authority Raving Jurisdiction I have witnessed a satisfacto acceptance test of this system and find it to be installed and operating properly in accordance with its approve p1- s and ecifications,its approved sequence of operraftiioo s,and with all NFPA standards cited here' Signed: / - Printed name: v'!#T 4-rev-s, Date: ,S /S` Organization: , Title: J�[�K�yL I Phone: • NFPi4 72,Fig.4.5.2.1 (p.5 of 5) Copyright C2009 National Fire Protection Association.The form may be copied for individual use other than for resale.ft may not be copied for commercial sale or distribution.